1
|
Yao L, Liu Q, Lei Z, Sun T. Development and challenges of antimicrobial peptide delivery strategies in bacterial therapy: A review. Int J Biol Macromol 2023; 253:126819. [PMID: 37709236 DOI: 10.1016/j.ijbiomac.2023.126819] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 09/06/2023] [Accepted: 09/07/2023] [Indexed: 09/16/2023]
Abstract
The escalating global prevalence of antimicrobial resistance poses a critical threat, prompting concerns about its impact on public health. This predicament is exacerbated by the acute shortage of novel antimicrobial agents, a scarcity attributed to the rapid surge in bacterial resistance. This review delves into the realm of antimicrobial peptides, a diverse class of compounds ubiquitously present in plants and animals across various natural organisms. Renowned for their intrinsic antibacterial activity, these peptides provide a promising avenue to tackle the intricate challenge of bacterial resistance. However, the clinical utility of peptide-based drugs is hindered by limited bioavailability and susceptibility to rapid degradation, constraining efforts to enhance the efficacy of bacterial infection treatments. The emergence of nanocarriers marks a transformative approach poised to revolutionize peptide delivery strategies. This review elucidates a promising framework involving nanocarriers within the realm of antimicrobial peptides. This paradigm enables meticulous and controlled peptide release at infection sites by detecting dynamic shifts in microenvironmental factors, including pH, ROS, GSH, and reactive enzymes. Furthermore, a glimpse into the future reveals the potential of targeted delivery mechanisms, harnessing inflammatory responses and intricate signaling pathways, including adenosine triphosphate, macrophage receptors, and pathogenic nucleic acid entities. This approach holds promise in fortifying immunity, thereby amplifying the potency of peptide-based treatments. In summary, this review spotlights peptide nanosystems as prospective solutions for combating bacterial infections. By bridging antimicrobial peptides with advanced nanomedicine, a new therapeutic era emerges, poised to confront the formidable challenge of antimicrobial resistance head-on.
Collapse
Affiliation(s)
- Longfukang Yao
- School of Chemistry, Chemical Engineering and Life Science, Wuhan University of Technology, 122 Luoshi Road, Wuhan 430070, China; Hubei Key Laboratory of Nanomedicine for Neurodegenerative Diseases, Wuhan University of Technology, 122 Luoshi Road, Wuhan 430070, China
| | - Qianying Liu
- School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Zhixin Lei
- School of Chemistry, Chemical Engineering and Life Science, Wuhan University of Technology, 122 Luoshi Road, Wuhan 430070, China; Hubei Key Laboratory of Nanomedicine for Neurodegenerative Diseases, Wuhan University of Technology, 122 Luoshi Road, Wuhan 430070, China.
| | - Taolei Sun
- School of Chemistry, Chemical Engineering and Life Science, Wuhan University of Technology, 122 Luoshi Road, Wuhan 430070, China; Hubei Key Laboratory of Nanomedicine for Neurodegenerative Diseases, Wuhan University of Technology, 122 Luoshi Road, Wuhan 430070, China.
| |
Collapse
|
2
|
Valtin J, Behrens S, Ruland A, Schmieder F, Sonntag F, Renner LD, Maitz MF, Werner C. A New In Vitro Blood Flow Model for the Realistic Evaluation of Antimicrobial Surfaces. Adv Healthc Mater 2023; 12:e2301300. [PMID: 37498721 DOI: 10.1002/adhm.202301300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 06/13/2023] [Indexed: 07/29/2023]
Abstract
Device-associated bloodstream infections can cause serious medical problems and cost-intensive postinfection management, defining a need for more effective antimicrobial coatings. Newly developed coatings often show reduced bacterial colonization and high hemocompatibility in established in vitro tests, but fail in animal studies or clinical trials. The poor predictive power of these models is attributed to inadequate representation of in vivo conditions. Herein, a new single-pass blood flow model, with simultaneous incubation of the test surface with bacteria and freshly-drawn human blood, is presented. The flow model is validated by comparative analysis of a recently developed set of antiadhesive and contact-killing polymer coatings, and the corresponding uncoated polycarbonate surfaces. The results confirm the model's ability to differentiate the antimicrobial activities of the studied surfaces. Blood activation data correlate with bacterial surface coverage: low bacterial adhesion is associated with low inflammation and hemostasis. Shear stress correlates inversely with bacterial colonization, especially on antiadhesive surfaces. The introduced model is concluded to enable the evaluation of novel antimicrobial materials under in vivo-like conditions, capturing interactions between bacteria and biomaterials surfaces in the presence of key components of the ex vivo host response.
Collapse
Affiliation(s)
- Juliane Valtin
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Stephan Behrens
- Fraunhofer Institute for Material and Beam Technology IWS, 01277, Dresden, Germany
| | - André Ruland
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Florian Schmieder
- Fraunhofer Institute for Material and Beam Technology IWS, 01277, Dresden, Germany
| | - Frank Sonntag
- Fraunhofer Institute for Material and Beam Technology IWS, 01277, Dresden, Germany
| | - Lars D Renner
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Manfred F Maitz
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
| | - Carsten Werner
- Leibniz Institute of Polymer Research Dresden, Institute of Biofunctional Polymer Materials, Hohe Strasse 6, 01069, Dresden, Germany
- Technische Universität Dresden, Cluster of Excellence Physics of Life, Center for Regenerative Therapies Dresden and Faculty of Chemistry and Food Chemistry, 01307, Dresden, Germany
| |
Collapse
|
3
|
Ahmed AAQ, Besio R, Xiao L, Forlino A. Outer Membrane Vesicles (OMVs) as Biomedical Tools and Their Relevance as Immune-Modulating Agents against H. pylori Infections: Current Status and Future Prospects. Int J Mol Sci 2023; 24:ijms24108542. [PMID: 37239888 DOI: 10.3390/ijms24108542] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 04/26/2023] [Accepted: 05/05/2023] [Indexed: 05/28/2023] Open
Abstract
Outer membrane vesicles (OMVs) are lipid-membrane-bounded nanoparticles that are released from Gram-negative bacteria via vesiculation of the outer membrane. They have vital roles in different biological processes and recently, they have received increasing attention as possible candidates for a broad variety of biomedical applications. In particular, OMVs have several characteristics that enable them to be promising candidates for immune modulation against pathogens, such as their ability to induce the host immune responses given their resemblance to the parental bacterial cell. Helicobacter pylori (H. pylori) is a common Gram-negative bacterium that infects half of the world's population and causes several gastrointestinal diseases such as peptic ulcer, gastritis, gastric lymphoma, and gastric carcinoma. The current H. pylori treatment/prevention regimens are poorly effective and have limited success. This review explores the current status and future prospects of OMVs in biomedicine with a special focus on their use as a potential candidate in immune modulation against H. pylori and its associated diseases. The emerging strategies that can be used to design OMVs as viable immunogenic candidates are discussed.
Collapse
Affiliation(s)
- Abeer Ahmed Qaed Ahmed
- Department of Molecular Medicine, Biochemistry Unit, University of Pavia, 27100 Pavia, Italy
| | - Roberta Besio
- Department of Molecular Medicine, Biochemistry Unit, University of Pavia, 27100 Pavia, Italy
| | - Lin Xiao
- School of Biomedical Engineering, Shenzhen Campus, Sun Yat-sen University, Shenzhen 518107, China
| | - Antonella Forlino
- Department of Molecular Medicine, Biochemistry Unit, University of Pavia, 27100 Pavia, Italy
| |
Collapse
|
4
|
Jahn M, Özçürümez MK, Dolff S, Rohn H, Heider D, Dechêne A, Canbay A, Rath PM, Katsounas A. A Multipathogen Bile Sample-based PCR Assay Can Guide Empirical Antimicrobial Strategies in Cholestatic Liver Diseases. J Clin Transl Hepatol 2022; 10:788-795. [PMID: 36304501 PMCID: PMC9547272 DOI: 10.14218/jcth.2021.00337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Revised: 10/19/2021] [Accepted: 01/29/2022] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND AND OBJECTIVES Polymerase chain reaction (PCR) techniques provide rapid detection of pathogens. This pilot study evaluated the diagnostic utility and clinical impact of multiplex real-time PCR (mRT-PCR, SeptiFast) vs. conventional microbial culture (CMC) in bile samples of patients with chronic cholestatic liver diseases (cCLDs), endoscopic retrograde cholangio-pancreatography (ERCP), and peri-interventional-antimicrobial-prophylaxis (pAP). METHODS We prospectively collected bile samples from 26 patients for microbiological analysis by CMC and mRT-PCR. Concordance of the results of both methods was determined by Krippendorff's alpha (α) for inter-rater reliability and the Jaccard index of similarity. RESULTS mRT-PCRbile and CMCbile results were concordant for only Candida albicans (α=0.8406; Jaccard index=0.8181). mRT-PCRbile detected pathogens in 8/8 cases (100%), CMCbile in 7/8 (87.5%), and CMCblood in 5/8 (62.5%) with clinical signs of infection. mRT-PCRbile, CMCbile, and CMCblood had identical detection results in 3/8 (37.5%) with clinical signs of infection (two Klebsiella spp. and one Enterococcus faecium). The total pathogen count was significantly higher with mRT-PCRbile than with CMCbile (62 vs. 31; χ2=30.031, p<0.001). However, pathogens detected by mRT-PCRbile were more often susceptible to pAP according to the patient infection/colonization history (PI/CH) and surveillance data for antibiotic resistance in our clinic (DARC). Pathogens identified by mRT-PCRbile and resistant to pAP by PI/CH and DARC were likely to be clinically relevant. CONCLUSIONS mRT-PCR in conjunction with CMCs for bile analysis increased diagnostic sensitivity and may benefit infection management in patients with cholestatic diseases. Implementation of mRT-PCR in a bile sample-based diagnostic routine can support more rapid and targeted use of antimicrobial agents in cCLD-patients undergoing ERCP and reduce the rate/length of unnecessary administration of broad-spectrum antibiotics.
Collapse
Affiliation(s)
- Michael Jahn
- Department of Nephrology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
- Correspondence to: Michael Jahn, Department of Nephrology, University Hospital Essen, Hufelandstrasse 55, Essen 45122, Germany. Tel: +49-201-723-83840, Fax: +49-201-723-5500, E-mail:
| | - Mustafa K Özçürümez
- Department of Medicine, Universitätsklinikum Knappschaftskrankenhaus Bochum, Ruhr-University Bochum, Bochum, Germany
| | - Sebastian Dolff
- Department of Infectious Diseases, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Hana Rohn
- Department of Infectious Diseases, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Dominik Heider
- Department of Mathematics and Computer Science, University of Marburg, Marburg, Germany
| | - Alexander Dechêne
- Department for Internal Medicine, Nuremberg Hospital North, Paracelsus Private Medical University Nuremberg, Nuremberg, Germany
| | - Ali Canbay
- Department of Medicine, Universitätsklinikum Knappschaftskrankenhaus Bochum, Ruhr-University Bochum, Bochum, Germany
| | - Peter M. Rath
- Institute of Medical Microbiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Antonios Katsounas
- Department of Medicine, Universitätsklinikum Knappschaftskrankenhaus Bochum, Ruhr-University Bochum, Bochum, Germany
| |
Collapse
|
5
|
Egli K, Risch M, Risch L, Bodmer T. Comparison of an automated DNA extraction and 16S rDNA real time PCR/sequencing diagnostic method using optimized reagents with culture during a 15-month study using specimens from sterile body sites. BMC Microbiol 2022; 22:119. [PMID: 35501697 PMCID: PMC9063205 DOI: 10.1186/s12866-022-02542-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 04/18/2022] [Indexed: 11/25/2022] Open
Abstract
Background 16S rDNA-PCR for the identification of a bacterial species is an established method. However, the DNA extraction reagents as well as the PCR reagents may contain residual bacterial DNA, which consequently generates false-positive PCR results. Additionally, previously used methods are frequently time-consuming. Here, we describe the results obtained with a new technology that uses DNA-free reagents for automated DNA extraction and subsequent real time PCR using sterile clinical specimens. Results In total, we compared 803 clinical specimens using real time PCR and culturing. The clinical specimens were mainly of orthopedic origin received at our diagnostic laboratory. In 595 (74.1%) samples, the results were concordant negative, and in 102 (12.7%) the results were concordant positive. A total of 170 (21.2%) clinical specimens were PCR-positive, of which 62 (36.5% from PCR positive, 7.7% in total) gave an additional benefit to the patient since only the PCR result was positive. Many of these 62 positive specimens were strongly positive based on crossingpoint values (54% < Cp 30), and these 62 positive clinical specimens were diagnosed as medically relevant as well. Thirty-eight (4.2%) clinical specimens were culture-positive (25 of them were only enrichment culture positive) but PCR-negative, mainly for S. epidermidis, S. aureus and C. acnes. The turnaround times for negative specimens were 4 hours (automated DNA extraction and real time PCR) and 1 working day for positive specimens (including Sanger sequencing). Melting-curve analysis of SYBR Green-PCR enables the differentiation of specific and unspecific PCR products. Using Ripseq, even mixed infections of 2 bacterial species could be resolved. Conclusions For endocarditis cases, the added benefit of PCR is obvious. The crucial innovations of the technology enable timely reporting of explicit reliable results for adequate treatment of patients. Clinical specimens with truly PCR-positive but culture-negative results represent an additional benefit for patients. Very few results at the detection limit still have to be critically examined.
Collapse
Affiliation(s)
| | | | - Lorenz Risch
- Dr Risch, 3097, Liebefeld, Switzerland.,Private University of the Principality of Liechtenstein, Triesen, Liechtenstein
| | | |
Collapse
|
6
|
A simple magnetic-assisted microfluidic method for rapid detection and phenotypic characterization of ultralow concentrations of bacteria. Talanta 2021; 230:122291. [PMID: 33934763 DOI: 10.1016/j.talanta.2021.122291] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 01/25/2021] [Accepted: 02/07/2021] [Indexed: 01/11/2023]
Abstract
Isolation and enumeration of bacteria at ultralow concentrations and antibiotic resistance profiling are of great importance for early diagnosis and treatment of bacteremia. In this work, we describe a simple, rapid, and versatile magnetic-assisted microfluidic method for rapid bacterial detection. The developed method enables magnetophoretic loading of bead-captured bacteria into the microfluidic chamber under external static and dynamic magnetic fields in 4 min. A shallow microfluidic chamber design that enables the monolayer orientation and transportation of the beads and a glass substrate with a thickness of 0.17 mm was utilized to allow high-resolution fluorescence imaging for quantitative detection. Escherichia coli (E. coli) with green fluorescent protein (GFP)-expressing gene and streptavidin-modified superparamagnetic microbeads were used as model bacteria and capturing beads, respectively. The specificity of the method was validated using Lactobacillus gasseri as a negative control group. The limit of detection and limit of quantification values were determined as 2 CFU/ml and 10 CFU/ml of E. coli, respectively. The magnetic-assisted microfluidic method is a versatile tool for the detection of ultralow concentrations of viable bacteria with the linear range of 5-5000 CFU/ml E. coli in 1 h, and providing growth curves and phenotypic characterization bead-captured E. coli in the following 5 h of incubation. Our results are promising for future rapid and sensitive antibiotic susceptibility testing of ultralow numbers of viable cells.
Collapse
|
7
|
Huber S, Weinberger J, Pilecky M, Lorenz I, Schildberger A, Weber V, Fuchs S, Posch W, Knabl L, Würzner R, Posch AE, Orth-Höller D. A high leukocyte count and administration of hydrocortisone hamper PCR-based diagnostics for bloodstream infections. Eur J Clin Microbiol Infect Dis 2021; 40:1441-1449. [PMID: 33547522 DOI: 10.1007/s10096-020-04126-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Accepted: 12/13/2020] [Indexed: 12/14/2022]
Abstract
Bloodstream infections (BSIs) require an accurate and fast identification of causative pathogens. Molecular diagnostics, in particular polymerase chain reaction (PCR)-based approaches for BSI diagnostics directly from whole blood, suffer from limitations such as inhibition leading to invalid results. In this retrospective study, we analyzed 23 parameters for their potential interference with LightCycler SeptiFast PCR tests (n = 2167) routinely performed at our institution. The overall inhibition rate was 9.1%. Test date, type of ward, procalcitonin levels, high leukocyte counts, and absolute neutrophil count were significantly associated with inhibition. For a subset (n = 448), cut-off values for leukocyte counts of < 5700 cells/μL and ≥ 26,900 cells/μL were significantly associated with a low (5%) and high (67%) inhibition risk. For patients with a moderate to high leukocyte count (5700-26,900 cells/μL), the additional administration of hydrocortisone significantly increased the inhibition risk. Furthermore, freezing of blood samples prior to DNA extraction and SF testing appeared to neutralize inhibitory factors. It remains to be investigated whether other molecular diagnostic tests are susceptible to similar inhibiting parameters.
Collapse
Affiliation(s)
- Silke Huber
- Institute of Hygiene and Medical Microbiology, Medical University of Innsbruck, Schöpfstrasse 41, 6020, Innsbruck, Austria
| | | | - Matthias Pilecky
- Center for Biomedical Technology, Department for Biomedical Research, Danube University Krems, Krems, Austria
| | - Ingo Lorenz
- Department of General and Surgical Critical Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
| | - Anita Schildberger
- Center for Biomedical Technology, Department for Biomedical Research, Danube University Krems, Krems, Austria
| | - Viktoria Weber
- Center for Biomedical Technology, Department for Biomedical Research, Danube University Krems, Krems, Austria.,Christian Doppler Laboratory for Innovative Therapy Approaches in Sepsis, Danube University Krems, Krems, Austria
| | - Stefan Fuchs
- Institute of Hygiene and Medical Microbiology, Medical University of Innsbruck, Schöpfstrasse 41, 6020, Innsbruck, Austria
| | - Wilfried Posch
- Institute of Hygiene and Medical Microbiology, Medical University of Innsbruck, Schöpfstrasse 41, 6020, Innsbruck, Austria
| | - Ludwig Knabl
- Institute of Hygiene and Medical Microbiology, Medical University of Innsbruck, Schöpfstrasse 41, 6020, Innsbruck, Austria
| | - Reinhard Würzner
- Institute of Hygiene and Medical Microbiology, Medical University of Innsbruck, Schöpfstrasse 41, 6020, Innsbruck, Austria
| | - Andreas E Posch
- Ares Genetics GmbH, Karl-Farkas-Gasse 18, 1030, Vienna, Austria.
| | - Dorothea Orth-Höller
- Institute of Hygiene and Medical Microbiology, Medical University of Innsbruck, Schöpfstrasse 41, 6020, Innsbruck, Austria.
| |
Collapse
|
8
|
Bagheri pebdeni A, Hosseini M. Fast and selective whole cell detection of Staphylococcus aureus bacteria in food samples by paper based colorimetric nanobiosensor using peroxidase-like catalytic activity of DNA-Au/Pt bimetallic nanoclusters. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105475] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
9
|
Development of a Prototype Lateral Flow Immunoassay for Rapid Detection of Staphylococcal Protein A in Positive Blood Culture Samples. Diagnostics (Basel) 2020; 10:diagnostics10100794. [PMID: 33036348 PMCID: PMC7601020 DOI: 10.3390/diagnostics10100794] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 09/14/2020] [Accepted: 09/21/2020] [Indexed: 12/22/2022] Open
Abstract
Bloodstream infection (BSI) is a major cause of mortality in hospitalized patients worldwide. Staphylococcus aureus is one of the most common pathogens found in BSI. The conventional workflow is time consuming. Therefore, we developed a lateral flow immunoassay (LFIA) for rapid detection of S. aureus-protein A in positive blood culture samples. A total of 90 clinical isolates including 58 S. aureus and 32 non-S. aureus were spiked in simulated blood samples. The antigens were extracted by a simple boiling method and diluted before being tested using the developed LFIA strips. The results were readable by naked eye within 15 min. The sensitivity of the developed LFIA was 87.9% (51/58) and the specificity was 93.8% (30/32). When bacterial colonies were used in the test, the LFIA provided higher sensitivity and specificity (94.8% and 100%, respectively). The detection limit of the LFIA was 107 CFU/mL. Initial evaluation of the LFIA in 20 positive blood culture bottles from hospitals showed 95% agreement with the routine methods. The LFIA is a rapid, simple and highly sensitive method. No sophisticated equipment is required. It has potential for routine detection particularly in low resource settings, contributing an early diagnosis that facilitates effective treatment and reduces disease progression.
Collapse
|