De Carolis E, Ivagnes V, Magrì C, Falasca B, Spanu T, Sanguinetti M. Evaluation of Autof MS2600 and MBT Smart MALDI-TOF MS Systems for Routine Identification of Clinical Bacteria and Yeasts. Microorganisms 2024; 12:382. [PMID: 38399786 PMCID: PMC10892063 DOI: 10.3390/microorganisms12020382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/07/2024] [Accepted: 02/09/2024] [Indexed: 02/25/2024] Open
Abstract
The identification of microorganisms at the species level has always constituted a diagnostic challenge for clinical microbiology laboratories. The aim of the present study has been the evaluation in a real-time assay of the performance of Autobio in comparison with the Bruker mass spectrometry system for the identification of bacteria and yeasts. A total of 535 bacteria and yeast were tested in parallel with the two systems by direct smear or fast formic acid extraction for bacteria and yeasts, respectively. Discordant results were verified by 16S, ITS rRNA or specific gene sequencing. Beyond giving comparable results for bacteria with respect to the MBT smart system, Autof MS2600 mass spectrometer provided excellent accuracy for the identification of yeast species of clinical interest.
Collapse
Affiliation(s)
- Elena De Carolis
- Dipartimento di Scienze di Laboratorio e Infettivologiche, Fondazione Policlinico Universitario “A. Gemelli” IRCCS, 00168 Rome, Italy; (V.I.); (C.M.); (B.F.); (T.S.)
| | | | | | | | | | - Maurizio Sanguinetti
- Dipartimento di Scienze di Laboratorio e Infettivologiche, Fondazione Policlinico Universitario “A. Gemelli” IRCCS, 00168 Rome, Italy; (V.I.); (C.M.); (B.F.); (T.S.)
| |
Collapse
|
2
|
Ao K, Li X, Zhang W, Chen Z, Liu Y, Shu L, Xiao Y, Wu S, Xie Y, Kang M. Evaluation of the Autof ms1000 mass spectrometry for rapid clinical identification of filamentous fungi. BMC Microbiol 2023; 23:228. [PMID: 37608359 PMCID: PMC10464221 DOI: 10.1186/s12866-023-02968-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 08/02/2023] [Indexed: 08/24/2023] Open
Abstract
BACKGROUND Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has revolutionized microbial identification. However, there is a lack of data on its performance in identifying filamentous fungi. The objective of our study was to evaluate the accuracy of the Autof ms1000 mass spectrometry for identifying filamentous fungi in the clinical microbiology laboratory. RESULTS Among 106 samples tested using the Autof ms1000 system, 101 (95.28%) were identified at the genus or species level, and 81 (76.41%) were accurately identified at the species level. Additionally, we developed a new rapid formic acid extraction method with simple pretreatment for filamentous fungi that saved time and provided accurate results. CONCLUSIONS The Autof ms1000 mass spectrometer proved to be a valuable tool for identifying filamentous fungi. However, upgrading the database is recommended for correctly identifying rare strains.
Collapse
Affiliation(s)
- Keping Ao
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Xiaohan Li
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Weili Zhang
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Zhixing Chen
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Ya Liu
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Ling Shu
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Yuling Xiao
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Siying Wu
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Yi Xie
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China
| | - Mei Kang
- Department of Laboratory Medicine, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, 610041, China.
| |
Collapse
|
3
|
Li S, Han D, Chen X, Zheng D, Cai Y, Lin D, Zhang X, Ke P, Qu P, Chen C. Evaluation of the Zybio EXS3000 mass spectrometry in routine identification of Clinical isolates. Heliyon 2023; 9:e18990. [PMID: 37600400 PMCID: PMC10432711 DOI: 10.1016/j.heliyon.2023.e18990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 07/25/2023] [Accepted: 08/04/2023] [Indexed: 08/22/2023] Open
Abstract
The matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been widely applied in routine clinical microbiology laboratories as an efficient and reliable technique for diagnostic purpose. In this work, we evaluated the performance of the newly developed Zybio EXS3000 (Zybio Inc., China) in microbial identification and compared it with VITEK MS (bioMérieux, France). For this study, a total of 1340 isolates from various clinical specimens were collected. These isolates were analyzed simultaneously on both EXS3000 and VITEK MS. The inconsistent or unidentifiable data were further identified using the help of either 16S rRNA gene or ITS region sequencing. During the study, we observed that EXS3000 and VITEK MS provided positive confirmatory diagnostics for 95.0% and 96.5% of the isolates, respectively, which were consistent with the sequencing results. However, it is worth noting that the EXS3000 system needs to improve the identification performance of Candida albicans in the follow-up. There are no significant differences between the two devices in terms of microbial identification performance. The advantage of EXS3000 over VITEK MS is in its ability to perform in significantly lesser time period. In conclusion, the results of this investigation showed that EXS3000 can be used to identify microorganisms in clinical microbiology laboratories.
Collapse
Affiliation(s)
- Song Li
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| | - Dexing Han
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xiaowei Chen
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Dexiang Zheng
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| | - Yimei Cai
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| | - Dongling Lin
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| | - Xuan Zhang
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| | - Peifeng Ke
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| | - Pinghua Qu
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| | - Cha Chen
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
- Department of Clinical Laboratory, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
| |
Collapse
|
4
|
Microbial Identification in the Clinical Microbiology Laboratory Using MALDI-TOF-MS. METHODS IN MOLECULAR BIOLOGY (CLIFTON, N.J.) 2021; 2420:207-216. [PMID: 34905176 DOI: 10.1007/978-1-0716-1936-0_16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
MALDI-TOF mass spectrometry has been applied with huge success to the identification of cultured microorganisms in clinical microbiology laboratories where it has become the reference method because it is simple, fast, and highly reproducible. We describe the different procedures used in the routine for pathogen identification using the Bruker MALDI Biotyper® system.
Collapse
|
5
|
Comparison of Autof ms1000 and Bruker Biotyper MALDI-TOF MS Platforms for Routine Identification of Clinical Microorganisms. BIOMED RESEARCH INTERNATIONAL 2021; 2021:6667623. [PMID: 33763483 PMCID: PMC7952152 DOI: 10.1155/2021/6667623] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 02/01/2021] [Accepted: 02/10/2021] [Indexed: 11/17/2022]
Abstract
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is widely used in clinical microbiology laboratories because it is cost-effective, reliable, and fast. This study is aimed at comparing the identification performance of the recently developed Autof ms1000 (Autobio, China) with that of the Bruker Biotyper (Bruker Daltonics, Germany). From January to June 2020, 205 preserved strains and 302 clinical isolates were used for comparison. Bacteria were tested with duplicates of the direct transfer method, and formic acid extraction was performed if the results were not at the species level. Fungi were tested with formic acid extraction followed by ethanol extraction methods. 16S rRNA or ITS region sequence analysis was performed on isolates that could not be identified by any of the instruments and on isolates that showed inconsistent results. The time to result of each instrument was also compared. Among preserved strains, species-level identification results were obtained in 202 (98.5%) strains by the Autof ms1000 and 200 (97.6%) strains by the Bruker Biotyper. Correct identification at the species/complex level was obtained for 200 (97.6%) strains by the Autof ms1000 and for 199 (97.1%) strains by the Bruker Biotyper. Among clinical isolates, species-level identification results were obtained in 301 (99.7%) strains and 300 (99.3%) strains by the Autof ms1000 and Bruker Biotyper, respectively. Correct identification at the species/complex level was achieved for 299 (99.0%) strains by the Autof ms1000 and for 300 (99.3%) strains by the Bruker Biotyper. The time to analyze 96 spots was approximately 14 min for the Autof ms1000 and approximately 27 min for the Bruker Biotyper. The two instruments showed comparable performance for the routine identification of clinical microorganisms. In addition, the Autof ms1000 has a short test time, making it convenient for use in clinical microbiology laboratories.
Collapse
|