1
|
Raes S, Prezzi A, Willems R, Heidbuchel H, Annemans L. Investigating the Cost-Effectiveness of Telemonitoring Patients With Cardiac Implantable Electronic Devices: Systematic Review. J Med Internet Res 2024; 26:e47616. [PMID: 38640471 PMCID: PMC11069092 DOI: 10.2196/47616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 09/13/2023] [Accepted: 02/13/2024] [Indexed: 04/21/2024] Open
Abstract
BACKGROUND Telemonitoring patients with cardiac implantable electronic devices (CIEDs) can improve their care management. However, the results of cost-effectiveness studies are heterogeneous. Therefore, it is still a matter of debate whether telemonitoring is worth the investment. OBJECTIVE This systematic review aims to investigate the cost-effectiveness of telemonitoring patients with CIEDs, focusing on its key drivers, and the impact of the varying perspectives. METHODS A systematic review was performed in PubMed, Web of Science, Embase, and EconLit. The search was completed on July 7, 2022. Studies were included if they fulfilled the following criteria: patients had a CIED, comparison with standard care, and inclusion of health economic evaluations (eg, cost-effectiveness analyses and cost-utility analyses). Only complete and peer-reviewed studies were included, and no year limits were applied. The exclusion criteria included studies with partial economic evaluations, systematic reviews or reports, and studies without standard care as a control group. Besides general study characteristics, the following outcome measures were extracted: impact on total cost or income, cost or income drivers, cost or income drivers per patient, cost or income drivers as a percentage of the total cost impact, incremental cost-effectiveness ratios, or cost-utility ratios. Quality was assessed using the Consensus Health Economic Criteria checklist. RESULTS Overall, 15 cost-effectiveness analyses were included. All studies were performed in Western countries, mainly Europe, and had primarily a male participant population. Of the 15 studies, 3 (20%) calculated the incremental cost-effectiveness ratio, 1 (7%) the cost-utility ratio, and 11 (73%) the health and cost impact of telemonitoring. In total, 73% (11/15) of the studies indicated that telemonitoring of patients with implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs was cost-effective and cost-saving, both from a health care and patient perspective. Cost-effectiveness results for telemonitoring of patients with pacemakers were inconclusive. The key drivers for cost reduction from a health care perspective were hospitalizations and scheduled in-office visits. Hospitalization costs were reduced by up to US $912 per patient per year. Scheduled in-office visits included up to 61% of the total cost reduction. Key drivers for cost reduction from a patient perspective were loss of income, cost for scheduled in-office visits and transport. Finally, of the 15 studies, 8 (52%) reported improved quality of life, with statistically significance in only 1 (13%) study (P=.03). CONCLUSIONS From a health care and patient perspective, telemonitoring of patients with an ICD or a cardiac resynchronization therapy ICD is a cost-effective and cost-saving alternative to standard care. Inconclusive results were found for patients with pacemakers. However, telemonitoring can lead to a decrease in providers' income, mainly due to a lack of reimbursement. Introducing appropriate reimbursement could make telemonitoring sustainable for providers while still being cost-effective from a health care payer perspective. TRIAL REGISTRATION PROSPERO CRD42022322334; https://tinyurl.com/puunapdr.
Collapse
Affiliation(s)
- Sarah Raes
- Department of Public Health and Primary Care, Ghent University, Gent, Belgium
| | - Andrea Prezzi
- Department of Public Health and Primary Care, Ghent University, Gent, Belgium
| | - Rik Willems
- Department of Cardiovascular Sciences, Universiteit Leuven, Leuven, Belgium
| | - Hein Heidbuchel
- Department of Genetics, Pharmacology and Physiopathology of Heart, Blood Vessels and Skeleton (GENCOR), Antwerp University, Antwerp, Belgium
| | - Lieven Annemans
- Department of Public Health and Primary Care, Ghent University, Gent, Belgium
| |
Collapse
|
2
|
Kawakami H, Saito M, Fujisawa T, Nagai T, Nishimura K, Akazawa Y, Miyoshi T, Higaki A, Seike F, Higashi H, Inoue K, Ikeda S, Yamaguchi O. A cost-effectiveness analysis of remote monitoring after pacemaker implantation for bradycardia in Japan. J Cardiol 2023; 82:388-397. [PMID: 37343930 DOI: 10.1016/j.jjcc.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 06/08/2023] [Accepted: 06/13/2023] [Indexed: 06/23/2023]
Abstract
BACKGROUND Although remote monitoring (RM) after pacemaker implantation is common, its cost-effectiveness has not been fully investigated. Therefore, we assessed the cost-effectiveness of RM compared with conventional follow-up (CFU) in Japanese patients with pacemakers. METHODS A Markov model was constructed to analyze costs and quality-adjusted life years after pacemaker implantation. The target population was Japanese patients implanted with a dual-chamber pacemaker for bradycardia. Transition probabilities (e.g. atrial fibrillation, stroke, and device trouble) were obtained from literature and expert sources. Additionally, stroke risk was determined according to anticoagulation and CHADS2 scores. We used a 10-year horizon with sensitivity analyses for significant variables. RESULTS Compared to CFU, RM was more effective; however, it was also more expensive. When the range of the Japanese willingness-to-pay threshold was considered to be ¥5,000,000, RM was at least cost-neutral relative to the CFU in all elderly patients with pacemakers for bradycardia. The cost-effectiveness of RM relative to CFU could be higher for patients with high CHADS2 scores, especially in patients with a CHADS2 score ≥ 3. Scenario analyses changing the interval between visits to an in-office evaluation in the CFU also demonstrated the same conclusions. In particular, when the interval between office visits was 1 year for the CFU, the RM could be more cost-effective. CONCLUSIONS This study demonstrated that RM can be a cost-effective option for Japanese patients, especially those with high CHADS2 scores and long-term intervals between office visits.
Collapse
Affiliation(s)
- Hiroshi Kawakami
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan.
| | - Makoto Saito
- Department of Cardiology, Kitaishikai Hospital, Ozu, Japan
| | - Tomoki Fujisawa
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Takayuki Nagai
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Kazuhisa Nishimura
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Yusuke Akazawa
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Toru Miyoshi
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Akinori Higaki
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Fumiyasu Seike
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Haruhiko Higashi
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Katsuji Inoue
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Shuntaro Ikeda
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| | - Osamu Yamaguchi
- Department of Cardiology, Pulmonology, Nephrology and Hypertension, Ehime University Graduate School of Medicine, Toon, Japan
| |
Collapse
|
3
|
Menezes Junior AS, Rivera A, Ayumi Miyawaki I, Gewehr DM, Nascimento B. Long-Term Remote vs. Conventional Monitoring of Pacemakers: Systematic Review and Meta-Analysis of Randomized Controlled Trials. Curr Cardiol Rep 2023; 25:1415-1424. [PMID: 37751037 DOI: 10.1007/s11886-023-01963-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/11/2023] [Indexed: 09/27/2023]
Abstract
PURPOSE OF REVIEW Remote monitoring (RM) is the standard of care for patients with cardiac implantable electronic devices (CIEDs), particularly pacemakers. However, the long-term outcomes of RM versus conventional monitoring (CM) of pacemakers and its effectiveness in reducing in-office (IO) visits for device reprogramming require elucidation. This systematic review and meta-analysis aimed to compare the RM and CM of pacemakers over a long-term follow-up. RECENT FINDINGS We systematically searched the PubMed/MEDLINE, Embase, Cochrane, and ClinicalTrials.gov databases for randomized controlled trials (RCTs) comparing RM and CM of pacemakers with at least 12 months of follow-up. Binary endpoints were pooled with risk ratios (RRs), whereas continuous outcomes were computed using mean differences (MDs) or standardized MDs (SMDs). Heterogeneity was assessed using I2 statistics. Among the eight included RCTs, 2159 (48.9%) of 4063 patients underwent RM. Follow-up periods ranged from 12 to 24 months. There were no significant between-group differences in all-cause mortality (RR = 1.19; 95% confidence interval [CI], 0.90-1.57; p = 0.22; I2 = 0%), stroke (RR = 0.90; 95% CI, 0.43-1.91; p = 0.79; I2 = 23%), hospitalizations for cardiovascular and/or device-related adverse events (RR = 0.95; 95% CI, 0.75-1.21; p = 0.70; I2 = 0%), and quality of life (SMD = - 0.06; 95% CI, - 0.22 to 0.10; p = 0.473; I2 = 0%). RM was associated with fewer IO visits/patient/year (MD = 0.98; 95% CI, - 1.64 to - 0.33; p = 0.08; I2 = 98%) and higher rates of atrial tachyarrhythmia (ATA) detection (RR = 1.22; 95% CI, 1.01-1.48; p = 0.04; I2 = 0%) than was CM. This meta-analysis suggests that RM of pacemakers leads to higher rates of ATA detection and fewer IO visits/patient/year, without compromising patient safety.
Collapse
Affiliation(s)
| | - André Rivera
- Department of Medicine, Nove de Julho University, São Bernardo do Campo, Brazil
| | | | - Douglas Mesadri Gewehr
- Curitiba Heart Institute, Curitiba, Brazil
- Science, and Technology, Denton Cooley Institute of Research, Curitiba, Brazil
| | - Bárbara Nascimento
- Department of Medicine, Federal University of Rio Grande do Sul, Porto Alegre, Brazil
| |
Collapse
|
4
|
Ferrick AM, Raj SR, Deneke T, Kojodjojo P, Lopez-Cabanillas N, Abe H, Boveda S, Chew DS, Choi JI, Dagres N, Dalal AS, Dechert BE, Frazier-Mills CG, Gilbert O, Han JK, Hewit S, Kneeland C, DeEllen Mirza S, Mittal S, Ricci RP, Runte M, Sinclair S, Alkmim-Teixeira R, Vandenberk B, Varma N. 2023 HRS/EHRA/APHRS/LAHRS expert consensus statement on practical management of the remote device clinic. Heart Rhythm 2023; 20:e92-e144. [PMID: 37211145 DOI: 10.1016/j.hrthm.2023.03.1525] [Citation(s) in RCA: 40] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 03/28/2023] [Indexed: 05/23/2023]
Abstract
Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
Collapse
Affiliation(s)
| | | | | | | | | | - Haruhiko Abe
- University of Occupational and Environmental Health Hospital, Kitakyushu, Japan
| | | | | | | | - Nikolaos Dagres
- Heart Center Leipzig at the University of Leipzig, Leipzig, Germany
| | - Aarti S Dalal
- Vanderbilt University Medical Center, Nashville, Tennessee
| | | | | | - Olivia Gilbert
- Wake Forest Baptist Medical Center, Winston-Salem, North Carolina
| | - Janet K Han
- VA Greater Los Angeles Healthcare System, Los Angeles, California
| | | | | | | | | | | | - Mary Runte
- University of Lethbridge, Lethbridge, Alberta, Canada
| | | | | | - Bert Vandenberk
- University of Calgary, Calgary, Alberta, Canada; Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | | |
Collapse
|
5
|
Ferrick AM, Raj SR, Deneke T, Kojodjojo P, Lopez-Cabanillas N, Abe H, Boveda S, Chew DS, Choi JI, Dagres N, Dalal AS, Dechert BE, Frazier-Mills CG, Gilbert O, Han JK, Hewit S, Kneeland C, Mirza SD, Mittal S, Ricci RP, Runte M, Sinclair S, Alkmim-Teixeira R, Vandenberk B, Varma N, Davenport E, Freedenberg V, Glotzer TV, Huang JL, Ikeda T, Kramer DB, Lin D, Rojel-Martínez U, Stühlinger M, Varosy PD. 2023 HRS/EHRA/APHRS/LAHRS Expert Consensus Statement on Practical Management of the Remote Device Clinic. Europace 2023; 25:euad123. [PMID: 37208301 PMCID: PMC10199172 DOI: 10.1093/europace/euad123] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/21/2023] Open
Abstract
Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
Collapse
Affiliation(s)
| | | | | | | | | | - Haruhiko Abe
- University of Occupational and Environmental Health Hospital, Kitakyushu, Japan
| | | | | | | | - Nikolaos Dagres
- Heart Center Leipzig at the University of Leipzig, Leipzig, Germany
| | - Aarti S Dalal
- Vanderbilt University Medical Center, Nashville, Tennessee
| | | | | | - Olivia Gilbert
- Wake Forest Baptist Medical Center, Winston-Salem, North Carolina
| | - Janet K Han
- VA Greater Los Angeles Healthcare System, Los Angeles, California
| | | | | | | | | | | | - Mary Runte
- University of Lethbridge, Lethbridge, Alberta, Canada
| | | | | | - Bert Vandenberk
- University of Calgary, Calgary, Alberta, Canada
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Vandenberk B, Raj SR. Remote Patient Monitoring: What Have We Learned and Where Are We Going? CURRENT CARDIOVASCULAR RISK REPORTS 2023; 17:103-115. [PMID: 37305214 PMCID: PMC10122094 DOI: 10.1007/s12170-023-00720-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/28/2023] [Indexed: 06/13/2023]
Abstract
Purpose of Review Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is an important part of patient follow-up. The increasing number of patients with CIEDs and the recent pandemic pose several challenges for already limited device clinic resources. This review focuses on recent evolutions in RM and identifies future needs to improve RM. Recent Findings RM has been associated with multiple clinical benefits, including improved survival, early detection of actionable events, reduction in inappropriate shocks, longer battery lives, and more efficient healthcare utilization. The survival benefit was driven by studies using alert-based continuous RM with daily transmissions and fast reaction times. Patients report a high satisfaction rate without significant differences in quality of life between RM and in-office follow-up.The increasing workload, due to the increasing number of CIEDs implanted with daily remote transmissions, results in several challenges for the future of RM. RM requires appropriate reimbursement for RM device clinics to optimize patient/staff ratios, including sufficient non-clinical and administrative support. Universal alert programming and data processing may minimize inter-manufacturer differences, improve the signal-to-noise ratio, and allow the development of standard operating protocols and workflows. In the future, programming by remote control and true remote programming may further improve remote CIED management, patient quality of life, and device clinic workflows. Summary RM should be considered standard of care in management of patients with CIEDs. The clinical benefits of RM can be maximized by an alert-based continuous RM model. Adapted healthcare policies are required to keep RM manageable for the future.
Collapse
Affiliation(s)
- Bert Vandenberk
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Satish R. Raj
- Department of Cardiac Sciences, Cumming School of Medicine, Libin Cardiovascular Institute, University of Calgary, GAC70 HRIC Building, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6 Canada
- Autonomic Dysfunction Center, Division of Clinical Pharmacology, Department of Medicine, Vanderbilt University Medical Center, Nashville, TN USA
| |
Collapse
|
7
|
Aboye GT, Vande Walle M, Simegn GL, Aerts JM. mHealth in sub-Saharan Africa and Europe: A systematic review comparing the use and availability of mHealth approaches in sub-Saharan Africa and Europe. Digit Health 2023; 9:20552076231180972. [PMID: 37377558 PMCID: PMC10291558 DOI: 10.1177/20552076231180972] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 05/23/2023] [Indexed: 06/29/2023] Open
Abstract
Background mHealth can help with healthcare service delivery for various health issues, but there's a significant gap in the availability and use of mHealth systems between sub-Saharan Africa and Europe, despite the ongoing digitalization of the global healthcare system. Objective This work aims to compare and investigate the use and availability of mHealth systems in sub-Saharan Africa and Europe, and identify gaps in current mHealth development and implementation in both regions. Methods The study adhered to the PRISMA 2020 guidelines for article search and selection to ensure an unbiased comparison between sub-Saharan Africa and Europe. Four databases (Scopus, Web of Science, IEEE Xplore, and PubMed) were used, and articles were evaluated based on predetermined criteria. Details on the mHealth system type, goal, patient type, health concern, and development stage were collected and recorded in a Microsoft Excel worksheet. Results The search query produced 1020 articles for sub-Saharan Africa and 2477 articles for Europe. After screening for eligibility, 86 articles for sub-Saharan Africa and 297 articles for Europe were included. To minimize bias, two reviewers conducted the article screening and data retrieval. Sub-Saharan Africa used SMS and call-based mHealth methods for consultation and diagnosis, mainly for young patients such as children and mothers, and for issues such as HIV, pregnancy, childbirth, and child care. Europe relied more on apps, sensors, and wearables for monitoring, with the elderly as the most common patient group, and the most common health issues being cardiovascular disease and heart failure. Conclusion Wearable technology and external sensors are heavily used in Europe, whereas they are seldom used in sub-Saharan Africa. More efforts should be made to use the mHealth system to improve health outcomes in both regions, incorporating more cutting-edge technologies like wearables internal and external sensors. Undertaking context-based studies, identifying determinants of mHealth systems use, and considering these determinants during mHealth system design could enhance mHealth availability and utilization.
Collapse
Affiliation(s)
- Genet Tadese Aboye
- M3-BIORES (Measure, Model & Manage Bioreponses), Division of Animal and Human Health Engineering, Department of Biosystems, KU Leuven, Leuven, Belgium
- School of Biomedical Engineering, Jimma University, Jimma, Ethiopia
| | - Martijn Vande Walle
- M3-BIORES (Measure, Model & Manage Bioreponses), Division of Animal and Human Health Engineering, Department of Biosystems, KU Leuven, Leuven, Belgium
| | | | - Jean-Marie Aerts
- M3-BIORES (Measure, Model & Manage Bioreponses), Division of Animal and Human Health Engineering, Department of Biosystems, KU Leuven, Leuven, Belgium
| |
Collapse
|
8
|
Lappegård KT, Moe F. Remote Monitoring of CIEDs-For Both Safety, Economy and Convenience? INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 19:ijerph19010312. [PMID: 35010572 PMCID: PMC8751026 DOI: 10.3390/ijerph19010312] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 12/17/2021] [Accepted: 12/25/2021] [Indexed: 05/17/2023]
Abstract
Cardiac implantable electronic devices such as pacemakers and defibrillators are increasingly monitored by systems transmitting information directly from the patient to the hospital. This may increase safety and patient satisfaction and also under certain circumstances represent an economic advantage. The review summarizes some of the recent research in the field of remote monitoring of cardiac devices.
Collapse
Affiliation(s)
- Knut Tore Lappegård
- Department of Medicine, Nordland Hospital, N-8092 Bodo, Norway;
- Department of Clinical Medicine, UiT The Arctic University of Norway, N-9037 Tromso, Norway
- Correspondence:
| | - Frode Moe
- Department of Medicine, Nordland Hospital, N-8092 Bodo, Norway;
| |
Collapse
|
9
|
Catalan-Matamoros D, Lopez-Villegas A, Leal Costa C, Bautista-Mesa R, Robles-Musso E, Rocamora Perez P, Lopez-Liria R. A non-randomized clinical trial to examine patients' experiences and communication during telemonitoring of pacemakers after five years follow-up. PLoS One 2021; 16:e0261158. [PMID: 34941904 PMCID: PMC8699982 DOI: 10.1371/journal.pone.0261158] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 11/26/2021] [Indexed: 12/12/2022] Open
Abstract
Patients with pacemakers need regular follow-ups which are demanding. Telemonitoring for pacemaker can provide a new opportunity to avoid follow-up visits. On the other hand, in-person visits could help patients with pacemakers to cope better with the anxiety linked to their condition and maintain better communication with their doctors than simple remote control of their device status. Therefore, our objective was to analyze the experiences and communication comparing telemonitoring (TM) versus conventional monitoring (CM) of patients with pacemakers. A single-center, controlled, non-randomized, non-blinded clinical trial was designed. Data were collected five years after implantation in a cohort of 89 consecutive patients assigned to two different groups: TM and CM. The ‘Generic Short Patient Experiences Questionnaire’ (GS-PEQ) was used to assess patients’ experiences, and the Healthcare Communication Questionnaire (HCCQ) was used to measure the communication of patients with healthcare professionals. Additionally, an ad-hoc survey including items from the ‘Telehealth Patient Satisfaction Survey’ and a ‘costs survey’ was used. After five years, 55 patients completed the study (TM = 21; CM = 34). Participants’ mean (±SD) age was 81 (±6.47), and 31% were females. No differences in baseline characteristics between groups were found. The comparative analyses TM versus CM showed some significant differences. According to GS-PEQ, TM users received adequate information about their diagnosis or afflictions (p = .035) and the treatment was better adapted to their situation (p = .009). Both groups reported negative experiences regarding their involvement in their treatment decisions, the waiting time before admission, and perceived a low-benefit. According to HCCQ, the TM group experienced poorer consultation management by the healthcare provider (p = .041). Participants reported positive overall communication experiences. The study provides insights into the experiences and communication in PM monitoring services as well as specific areas where users reported negative experiences such as the consultation management by clinicians. Trial registration: ClinicalTrials.gov NCT02234245.
Collapse
Affiliation(s)
- Daniel Catalan-Matamoros
- Health Research Centre, University of Almeria, Almeria, Spain
- Department of Communication Studies, University Carlos III of Madrid, Madrid, Spain
| | - Antonio Lopez-Villegas
- Social Involvement of Critical and Emergency Medicine, CTS-609 Research Group, Hospital de Poniente, El Ejido-Almeria, Spain
- * E-mail:
| | | | | | | | - Patricia Rocamora Perez
- Health Research Centre, University of Almeria, Almeria, Spain
- Department of Nursing Science, Physiotherapy and Medicine, University of Almeria, Almeria, Spain
| | - Remedios Lopez-Liria
- Health Research Centre, University of Almeria, Almeria, Spain
- Department of Nursing Science, Physiotherapy and Medicine, University of Almeria, Almeria, Spain
| |
Collapse
|
10
|
Lopez-Villegas A, Leal-Costa C, Perez-Heredia M, Villegas-Tripiana I, Catalán-Matamoros D. Knowledge Update on the Economic Evaluation of Pacemaker Telemonitoring Systems. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph182212120. [PMID: 34831876 PMCID: PMC8624333 DOI: 10.3390/ijerph182212120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 11/15/2021] [Accepted: 11/16/2021] [Indexed: 11/16/2022]
Abstract
(1) Introduction: In the last two decades, telemedicine has been increasingly applied to telemonitoring (TM) of patients with pacemakers; however, presently, its growth has significantly accelerated because of the COVID-19 pandemic, which has pushed patients and healthcare workers alike to seek new ways to stay healthy with minimal physical contact. Therefore, the main objective of this study was to update the current knowledge on the differences in the medium-and long-term effectiveness of TM and conventional monitoring (CM) in relation to costs and health outcomes. (2) Methods: Three databases and one scientific registry were searched (PubMed, EMBASE, Scopus, and Google Scholar), with no restrictions on language or year of publication. Studies published until July 2021 were included. The inclusion criteria were: (a) experimental or observational design, (b) complete economic evaluation, (c) patients with implanted pacemakers, and (d) comparison of TM with CM. Measurements of study characteristics (author, study duration, sample size, age, sex, major indication for implantation, and pacemaker used), analysis, significant results of the variables (analysis performed, primary endpoints, secondary endpoints, health outcomes, and cost outcomes), and further miscellaneous measurements (methodological quality, variables coded, instrument development, coder training, and intercoder reliability, etc.) were included. (3) Results: 11 studies met the inclusion criteria, consisting of 3372 enrolled patients; 1773 (52.58%) of them were part of randomized clinical trials. The mean age was 72 years, and the atrioventricular block was established as the main indication for device implantation. TM was significantly effective in detecting the presence or absence of pacemaker problems, leading to a reduction in the number of unscheduled hospital visits (8.34-55.55%). The cost of TM was up to 87% lower than that of CM. There were no significant differences in health-related quality of life (HRQoL) and the number of cardiovascular events. (4) Conclusions: Most of the studies included in this systematic review confirm that in the TM group of patients with pacemakers, cardiovascular events are detected and treated earlier, and the number of unscheduled visits to the hospital is significantly reduced, without affecting the HRQoL of patients. In addition, with TM modality, both formal and informal costs are significantly reduced in the medium and long term.
Collapse
Affiliation(s)
- Antonio Lopez-Villegas
- Social Involvement of Critical and Emergency Medicine, CTS-609 Research Group, Poniente Hospital, 04700 El Ejido-Almería, Spain;
| | - César Leal-Costa
- Nursing Department, University of Murcia, 30120 Murcia, Spain
- Correspondence: ; Tel.: +34-868-889-771
| | - Mercedes Perez-Heredia
- Research Management Department, Primary Care District Poniente of Almería, 04700 El Ejido-Almería, Spain;
| | | | - Daniel Catalán-Matamoros
- UC3M MediaLab, Department of Communication and Media Studies, Madrid University Carlos III, 28903 Madrid, Spain;
- Health Sciences Research Institute, University of Almería, 04120 Almería, Spain
| |
Collapse
|