1
|
Sun H, Wang C, Wu H. Recent advances and current challenges in suture and sutureless scleral fixation techniques for intraocular lens: a comprehensive review. EYE AND VISION (LONDON, ENGLAND) 2024; 11:49. [PMID: 39736769 DOI: 10.1186/s40662-024-00414-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Accepted: 11/01/2024] [Indexed: 01/01/2025]
Abstract
Over the past two decades, both suture and sutureless techniques for scleral fixation of intraocular lenses have seen significant advancement, driven by improvements in methodologies and instrumentation. Despite numerous reports demonstrating the effectiveness, safety, and superiority of these techniques, each approach carries with it its own drawbacks, including an elevated risk of certain postoperative complications. This article delves into various surgical techniques for scleral fixation of posterior chamber intraocular lenses, discussing their procedural nuances, benefits, drawbacks, postoperative complications, and outcomes. Furthermore, a comparative analysis between suture and sutureless fixation methods is presented, elucidating their respective limitations and associated factors. It is hoped that this comprehensive review will offer clinicians guidance on how to individualize procedural selection and mitigate surgical risks, and thus achieve optimal visual outcomes. This review will also endeavor to provide guidance for future advancements in intraocular lens fixation techniques.
Collapse
Affiliation(s)
- Han Sun
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
| | - Caixia Wang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
| | - Hong Wu
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China.
| |
Collapse
|
2
|
Boz AAE, Atum M, Özmen S, Yuvacı İ, Çelik E. Comparison of three different intraocular lens implantation techniques in the absence of capsular support: sutured scleral, haptic flanged intrascleral, and four flanged intrascleral fixations. Int Ophthalmol 2023; 43:5045-5053. [PMID: 37851141 DOI: 10.1007/s10792-023-02907-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Accepted: 09/28/2023] [Indexed: 10/19/2023]
Abstract
INTRODUCTION After lens extraction, if the capsular bag insufficiency occurs, there are different IOL implantation techniques. IOL implantation in the posterior chamber is safer in eyes with low endothelial cell count, peripheral anterior synechiae, shallow anterior chamber, and glaucoma. Alternative approaches for scleral fixation techniques, both with and without sutures, continue to undergo development. In this study, we aimed to compare the postoperative outcomes of the sutured scleral fixation (SSF), haptic flanged intrascleral fixation (HFISF) and four flanged intrascleral fixation (FFISF) IOL implantation techniques in eyes with the absence of capsular support. MATERIALS AND METHODS A hundred and thirty-seven aphakic eyes with the absence of capsular support were included in the study. The patients were divided into three groups: group 1-SSF, group 2-HFISF (Yamane technique), and group 3-FFISF. Surgical time in minutes, preoperative and postoperative parameters such as best corrected visual acuity (BCVA), corneal astigmatism, lenticular astigmatism, intraocular pressure (IOP), specular microscopy, central macular thickness (CMT) were recorded. Pseudophacodonesis was assessed at 6 months postoperatively using a slit lamp, and early and late complications were recorded. RESULTS Of the 137 eyes, 69 eyes were included in the SSF group, 41 eyes in the HFISF group, and 27 eyes in the FFISF group. No statistically significant differences were observed among the three groups in terms of age, gender, preoperative mean BCVA, corneal astigmatism, IOP, endothelial cell density, and CMT. It was observed that the mean BCVA significantly improved compared to the preoperative visual acuity in all three groups. Postoperative lenticular astigmatism, pseudophacodonesis score, percentage of the endothelial cell loss were found to be higher in FFISF groups. The surgical time was found to be shorter in the HFISF group. IOL decentration was observed in 1.44% of the SSF group and 7.40% of the FFISF group. Cystoid macular edema was observed in 5.79% of the SSF group, 4.87% of the HFISF group, and 7.40% of the FFISF group. Retinal detachment was observed in 1.44% of the SSF group and 7.31% of the HFISF group. CONCLUSIONS The optimal technique for treating aphakia without capsular support remains uncertain. Surgeons are tasked with a complex decision, aiming for both excellent vision and minimal risk. This decision is based on their expertise, the distinctive ocular condition of the patient, and the availability of essential operating room equipment. In this study, the following findings were observed: in the HFISF technique, the average surgical time was found to be shorter, the SSF technique demonstrated greater stability in terms of astigmatism and pseudophacodonesis and the FFISF technique was recognized for its relatively straightforward application method. It is important to note that the three IOL implantation techniques yielded comparable outcomes in terms of postoperative BCVA, as well as early and late complications.
Collapse
Affiliation(s)
- Ali Altan Ertan Boz
- Sakarya University Training and Research Hospital, Korukent Sitesi Mimoza 1/12 Korucuk Adapazarı, Sakarya, Turkey.
| | - Mahmut Atum
- Sakarya University Training and Research Hospital, Korukent Sitesi Mimoza 1/12 Korucuk Adapazarı, Sakarya, Turkey
| | - Sedat Özmen
- Sakarya University Training and Research Hospital, Korukent Sitesi Mimoza 1/12 Korucuk Adapazarı, Sakarya, Turkey
| | - İsa Yuvacı
- Sakarya University Training and Research Hospital, Korukent Sitesi Mimoza 1/12 Korucuk Adapazarı, Sakarya, Turkey
| | - Erkan Çelik
- Sakarya University Training and Research Hospital, Korukent Sitesi Mimoza 1/12 Korucuk Adapazarı, Sakarya, Turkey
| |
Collapse
|
3
|
Qi DM, Huo SJ, Yu T. Pupillary capture following sutureless scleral-fixated intraocular lens in children with Marfan syndrome. Int J Ophthalmol 2023; 16:1789-1793. [PMID: 38028516 PMCID: PMC10626357 DOI: 10.18240/ijo.2023.11.08] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 08/04/2023] [Indexed: 12/01/2023] Open
Abstract
AIM To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens (SFIOL) in children with Marfan syndrome (MFS). METHODS The study included 15 children (26 eyes) with lens subluxation due to MFS. These children underwent lensectomy, anterior vitrectomy, and sutureless SFIOL. According to the position of placement of intraocular lens (IOL) haptics, two study groups were reviewed for best corrected visual acuity (BCVA) and postoperative complications: group A, 14 eyes with haptics fixated at 2.0 mm from the limbus; group B, 12 eyes with the haptics fixated at 2.5 mm from the limbus. RESULTS The mean axial length for all patients was 25.66±2.35 mm. Postoperative BCVA in logMAR were significant improved in both groups (0.77±0.32 to 0.17±0.12 in group A, 0.66±0.25 to 0.24±0.12 in group B, both P<0.001) while no significant difference between two groups (P>0.05). Pupillary capture was main postoperative complication, occurring between 3d and 18mo. It occurred in 7 eyes in group A and one eye in group B (P=0.02). CONCLUSION Sutureless SFIOL is an effective treatment approach for lens subluxation in children with MFS. Pupillary capture is the main postoperative complication. Fixated IOL haptics at 2.5 mm from the limbus can reduce the occurrence of pupillary capture.
Collapse
Affiliation(s)
- Dong-Mei Qi
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Shu-Jia Huo
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Tao Yu
- Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| |
Collapse
|
4
|
Trans-Scleral Plugs Fixated FIL SSF IOL: A Review of the Literature and Comparison with Other Secondary IOL Implants. J Clin Med 2023; 12:jcm12051994. [PMID: 36902780 PMCID: PMC10004107 DOI: 10.3390/jcm12051994] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 02/26/2023] [Accepted: 03/01/2023] [Indexed: 03/06/2023] Open
Abstract
Purpose. To revise the current literature on FIL SSF (Carlevale) intraocular lens, previously known as Carlevale lens, and to compare their outcomes with those from other secondary IOL implants. Methods. We performed a peer review of the literature regarding FIL SSF IOLs until April 2021 and analyzed the results only of articles with a minimum of 25 cases and a follow-up of at least 6 months. The searches yielded 36 citations, 11 of which were abstracts of meeting presentations that were not included in the analysis because of their limited data. The authors reviewed 25 abstracts and selected six articles of possible clinical relevance to review in full text. Of these, four were considered to be sufficiently clinically relevant. Particularly, we extrapolated data regarding the pre- and postoperative best corrected visual acuities (BCVA) and the complications related to the procedure. The complication rates were then compared with those from a recently published Ophthalmic Technology Assessment by the American Academy of Ophthalmology (AAO) on secondary IOL implants. Results. Four studies with a total of 333 cases were included for results analysis. The BCVA improved in all cases after surgery, as expected. Cystoid macular edema (CME) and increased intraocular pressure were the most common complications, with an incidence of up to 7.4% and 16.5%, respectively. Other IOL types from the AAO report included anterior chamber IOLs, iris fixation IOLs, sutured iris fixation IOLs, sutured scleral fixation IOLs, and sutureless scleral fixation IOLs. There was no statistically significant difference in the rates of postoperative CME (p = 0.20), and vitreous hemorrhage (p = 0.89) between other secondary implants and the FIL SSF IOL, whereas the rate of retinal detachment was significantly less with FIL SSF IOLs (p = 0.04). Conclusion. The results of our study suggest the implantation of FIL SSF IOLs is an effective and safe surgical strategy in cases where there is a lack of capsular support. In fact, their outcomes seem to be comparable to those obtained with the other available secondary IOL implants. According to published literature, the FIL SSF (Carlevale) IOL provides favorable functional results with a low rate of postoperative complications.
Collapse
|
5
|
Shahid SM, Flores-Sánchez BC, Chan EW, Anguita R, Ahmed SN, Wickham L, Charteris DG. Scleral-fixated intraocular lens implants-evolution of surgical techniques and future developments. Eye (Lond) 2021; 35:2930-2961. [PMID: 34117388 PMCID: PMC8526814 DOI: 10.1038/s41433-021-01571-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 04/07/2021] [Accepted: 04/21/2021] [Indexed: 11/08/2022] Open
Abstract
Varied options are available for the implantation of secondary intraocular lens implants in the absence of zonular or capsular support. Loss of the capsule can occur in the context of complicated cataract surgery, trauma or inherited conditions such as Marfan syndrome or pseudoexfoliation. Approaches to overcome this include optical measures such as the use of spectacles or contact lenses, and surgical therapy incorporating the use of anterior chamber, iris-fixated or scleral-fixated lenses. Surgical techniques to implant scleral-fixated lenses have undergone various modifications, since the first publication of sutured intrascleral fixation described in the 1980s. However, despite the advances in surgical techniques, studies are limited either by their retrospective nature, small sample size and most importantly small duration of follow-up. This comprehensive review aims to amalgamate the evolution of various surgical techniques with regards to intrascleral lens fixation and suggests areas for future development.
Collapse
Affiliation(s)
- S M Shahid
- Vitreoretinal Service, Moorfields Eye Hospital, London, UK.
| | | | - E W Chan
- Vitreoretinal Service, Moorfields Eye Hospital, London, UK
| | - R Anguita
- Vitreoretinal Service, Moorfields Eye Hospital, London, UK
| | - S N Ahmed
- Ophthalmology Department, Northampton General Hospital, Cliftonville, Northampton, UK
| | - L Wickham
- Vitreoretinal Service, Moorfields Eye Hospital, London, UK
| | - D G Charteris
- Vitreoretinal Service, Moorfields Eye Hospital, London, UK
- UCL Institute of Ophthalmology, London, UK
| |
Collapse
|
6
|
Evaluation of the Findings of Patients Who Underwent Sutureless Flanged Transconjunctival Intrascleral Intraocular Lens Implantation with or without Pars Plana Vitrectomy. J Ophthalmol 2021; 2021:4617583. [PMID: 34513084 PMCID: PMC8428990 DOI: 10.1155/2021/4617583] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 08/21/2021] [Accepted: 08/27/2021] [Indexed: 11/28/2022] Open
Abstract
Purpose To compare the visual outcomes and complications of patients who underwent flanged transconjunctival sutureless intrascleral intraocular lens (SIS IOL) implantation after anterior and pars plana vitrectomy. Methods All patients who underwent flanged transconjunctival SIS IOL fixation using a 27-gauge needle between September 2017 and November 2019 and were followed up for at least six months were evaluated. The cases in which anterior vitrectomy was performed were classified as Group 1, and those that underwent pars plana vitrectomy were classified as Group 2. The best-corrected visual acuity (BCVA), spherical equivalent values, corneal endothelial cell density, and intraocular pressures were compared between the two groups before and after the operation. Intraoperative and postoperative complications were assessed. Results The study included 108 eyes of 108 patients who were included in the study. Group 1 consisted of 48 patients and Group 2 comprised of 60 patients. When the findings between Groups 1 and 2 were compared in the postoperative period, there was no statistically significant difference in terms of the mean intraocular pressure increase, endothelial cell density, BCVA, and spherical equivalent value (P=0.818, 0.601, 0.368, and 0.675, respectively). When all the patients were considered as a single group, the mean spherical value at the sixth postoperative month was 0.3 ± 2.2 D (min-max, (−5.5)–(+6)), the mean cylindrical value was −1.7 ± 2.4 D (min-max, (−9.25)–(+4)), and the mean spherical equivalent value was −0.5 ± 2.3 D (min-max, (−6.5)–(+6)). Conclusion The flanged transconjunctival SIS IOL fixation technique performed using a 27-gauge needle is safe and effective in the patient group with aphakia and lens/IOL dislocation or subluxation. However, in patients planned to undergo flanged transconjunctival SIS IOL implantation, pars plana vitrectomy seems to be a more suitable option than anterior vitrectomy to reduce complications.
Collapse
|
7
|
Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up. J Ophthalmol 2021; 2021:5525064. [PMID: 34327011 PMCID: PMC8310451 DOI: 10.1155/2021/5525064] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 04/11/2021] [Accepted: 07/08/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose To evaluate long-term outcomes and complications of sutured scleral-fixated foldable intraocular lens (IOL) implantation. Design Retrospective study. Methods Patients who underwent sutured scleral-fixated foldable IOL implantation using 10-0 polypropylene suture were followed up for at least 5 years at one Chinese tertiary hospital and two primary hospitals. Results 52 eyes among 48 patients (35 male and 13 female) were evaluated. The mean age (years) was 50.27 ± 20.08 (range: 6 to 81). The mean postoperative follow-up time (months) was 79.70 ± 18.84 (range: 60 to 121). The mean best-corrected visual acuity (BCVA) improved from 0.83 ± 0.69 logarithm of the minimum angle of resolution (logMAR) at baseline to 0.50 ± 0.45 logMAR at the last follow-up visit. There was improved or unchanged BCVA in 44 eyes (84.62%) and reduced BCVA in 8 eyes (15.38%). Mild intraoperative intravitreal hemorrhage was observed in 3 eyes (5.77%). Early postoperative complications included transient elevated intraocular pressure (IOP) in 5 eyes (9.62%) and hypotony in 1 eye (1.92%). Secondary epimacular membrane occurred in 5 eyes (9.62%) and retinal detachment (RD; 3 years postsurgery), subconjunctival suture knot exposure (5 years postsurgery), and persistent elevated IOP (in a GRAVES patient) occurred in 1 eye (1.92%) each. No suture erosion or breakage nor IOL dislocation was observed. No visually threatening IOL tilt or decentration was reported in any patient. Conclusion Sutured scleral-fixated foldable IOL implantation demonstrated satisfactory long-term outcomes and rare suture-related complications. This technology was safe and did not require complicated equipment and is of considerable interest in the setting of aphakia without adequate capsule support.
Collapse
|
8
|
Mo B, Li SF. Novel use of an adjustable single 8-0 polypropylene suture of scleral fixation without conjunctival dissection. BMC Ophthalmol 2020; 20:304. [PMID: 32711502 PMCID: PMC7382057 DOI: 10.1186/s12886-020-01558-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 07/07/2020] [Indexed: 12/05/2022] Open
Abstract
Background This report serves to describe the use of a novel adjustable single 8–0 polypropylene suture for scleral fixation without conjunctival dissection, and to describe related clinical outcomes associated with this approach. Methods In this study, we retrospectively reviewed 28 eyes from 27 patients that underwent scleral fixation of the intraocular lens (IOL) without conjunctival dissection using an adjustable single 8–0 polypropylene suture at the Beijing Tongren Eye Center between April 2018 and April 2019. For this surgical approach, a 23-gauge infusion cannula was set, after which two Hoffmann scleral pockets were created. Next, 8–0 polypropylene sutures were inserted into the eye guided by 10–0 polypropylene sutures of a long straight needle. The 8–0 suture was then used to fix the haptic IOs. Finally, these 8–0 polypropylene sutures were removed from the scleral pockets, and knots were tightened with the adjustable single suture. Primary outcomes included visual acuity and postoperative complication incidence. Results For this study, outcomes for 28 eyes from 27 patients (9 female, 18 male) were assessed. Patients had a mean age of 54 ± 15.11 years-old and were followed for an average of 10.18 ± 2.76 months postoperatively. Uncorrected visual acuity in these patients improved significantly from a preoperative value of 1.269 ± 0.464 logMAR to a 3-month postoperative value of 0.409 ± 0.413 logMAR (p = 0.000). The majority of postoperative complications in these patients were temporary and self-limiting, including corneal edema (35.71%), hypotony (14.29%), elevated intraocular pressure (28.58%), and mild hyphema (7.14%). No evidence of exposure or erosion of the trimmed suture end was detected in any patients. An ultrasound biomicroscope was able to readily detect the IOL and all sutures, and IOLs were found to be well-centered without any dislocation, tilting, or subluxation upon follow-up. Conclusions An adjustable single 8–0 polypropylene suture can reliably and effectively be used for scleral fixation without conjunctival dissection for the treatment of patients with aphakia or inadequate posterior capsule support. The novel procedure described herein may therefore be an effective means of minimizing the risk of suture-related complications in patients undergoing scleral-fixated IOL implantation. Trial registration Retrospective case series study, not applicable. NCT04476264.
Collapse
Affiliation(s)
- Bin Mo
- Beijing Tongren Eye Center, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Hospital, Capital Medical University, No. 1 Dong Jiao Min Xiang, Eastern District, Beijing, 100730, China
| | - Song-Feng Li
- Beijing Tongren Eye Center, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Hospital, Capital Medical University, No. 1 Dong Jiao Min Xiang, Eastern District, Beijing, 100730, China.
| |
Collapse
|
9
|
Intraocular Lens Implantation in the Absence of Zonular Support: An Outcomes and Safety Update: A Report by the American Academy of Ophthalmology. Ophthalmology 2020; 127:1234-1258. [PMID: 32507620 DOI: 10.1016/j.ophtha.2020.03.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 03/03/2020] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To review the published literature on the visual acuity results and complications of different surgical techniques for intraocular lens (IOL) implantation in the absence of zonular support. METHODS Peer-reviewed literature searches were conducted last in PubMed and the Cochrane Library in July 2019. The searches yielded 734 citations of articles published in English. The panel reviewed the abstracts of these mostly retrospective case series studies, and 45 were determined to be relevant to the assessment objectives. Three articles were rated as level II evidence, and 42 articles were rated as level III evidence. RESULTS Eight different types of IOL fixation techniques with at least 6-month follow-up were evaluated: anterior chamber IOL (ACIOL), iris-claw IOL, retropupillary iris-claw IOL, 10-0 polypropylene iris-sutured posterior chamber IOL (PCIOL), 10-0 polypropylene scleral-sutured PCIOL, 8-0 polypropylene scleral-sutured PCIOL, CV-8 polytetrafluoroethylene, and intrascleral haptic fixation (ISHF). Eight articles reported data comparing 2 techniques. The 45 studies had insufficient statistical power to compare the techniques conclusively. A qualitative analysis of similar types showed that trends in visual acuity outcomes were not inferior to those of ACIOL implantation, but the severity of preoperative pathologic features was not controlled for. Compared with ACIOL, complications of cystoid macular edema were higher in 10-0 polypropylene iris-sutured PCIOL and 8-0 polypropylene scleral-sutured PCIOL. Non-anterior chamber IOL techniques were less likely to report chronic uveitis. Chronic glaucoma was highest in the 8-0 polypropylene scleral-sutured PCIOL group. Although retinal detachment was infrequent overall, it was twice as common in both iris- and scleral-sutured PCIOLs (except CV-8 polytetrafluoroethylene suture) compared with nonsutured methods: ACIOL, iris-clipped IOL, and ISHF PCIOL. CONCLUSIONS The evidence reviewed shows no superiority of any single IOL implantation technique in the absence of zonular support. The various techniques seem to have equivalent visual acuity outcomes and safety profiles. Each technique has its own profile of inherent risk of postoperative complications. Surgeons must educate patients on the importance of close, long-term follow-up as a result of the uncertain nature of these techniques. Large prospective studies are needed to confirm the long-term complication profiles of these various IOL implantation techniques.
Collapse
|