1
|
Abreu RMD, Cairo B, Rehder-Santos P, da Silva CD, Signini ÉDF, Milan-Mattos JC, Sakaguchi CA, Catai AM, Porta A. Cardiorespiratory coupling is associated with exercise capacity in athletes: A cross-sectional study. Respir Physiol Neurobiol 2024; 320:104198. [PMID: 37956746 DOI: 10.1016/j.resp.2023.104198] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/24/2023] [Accepted: 11/09/2023] [Indexed: 11/15/2023]
Abstract
PURPOSE To determine the association between exercise capacity based on peak oxygen uptake (VO2peak) and resting cardiorespiratory coupling (CRC) levels in athletes and non-athletes' subjects. METHODS A cross-sectional study was carried out in 42 apparently healthy male subjects, aged between 20 and 40 years old. The participants were allocated into athletes (n = 21) and non-athletes (n = 21) groups. Resting electrocardiogram and respiratory movement (RESP) were simultaneously acquired during 15 min in supine position and quiet breathing. The beat-to-beat heart period (HP) and RESP series were determined from the recorded signals. Traditional analysis of HP based on frequency domain indexes was performed considering the high-frequency (0.15 - 0.45 Hz) components. To compute the CRC, the linear association between HP and RESP series was determined via squared coherence function and directionality of interaction was investigated through the causal extension of this approach. The exercise capacity was assessed through incremental cardiopulmonary exercise testing in order to determine the VO2peak. RESULTS Traditional analysis of HP based on high-frequency index was not correlated with exercise capacity in the athletes (r = -0.1, p = 0.5) and non-athletes (r = -0.1, p = 0.3) cohorts. However, resting CRC values was associated with exercise capacity in athletes (r = 0.4, p = 0.03), but not in the non-athletes group (r = -0.2, p = 0.3). CONCLUSION These results suggest that improved resting values of CRC is associated with higher exercise capacity (VO2peak) in endurance athletes. Moreover, frequency domain of HP was not sensitive to identifying this relationship, probably because effects of training on parasympathetic modulation might be affected by respiratory dynamics, and this influence has a directionality (i.e., from RESP to HP).
Collapse
Affiliation(s)
- Raphael Martins de Abreu
- LUNEX University, International University of Health, Exercise & Sports S.A. 50, Department of Physiotherapy, Differdange, Luxembourg; LUNEX ASBL Luxembourg Health & Sport Sciences Research Institute, Differdange, Luxembourg; Federal University of São Carlos, Department of Physical Therapy, São Carlos, São Paulo, Brazil.
| | - Beatrice Cairo
- University of Milan, Department of Biomedical Sciences for Health, Milan, Italy
| | - Patricia Rehder-Santos
- Federal University of São Carlos, Department of Physical Therapy, São Carlos, São Paulo, Brazil
| | | | - Étore De Favari Signini
- Federal University of São Carlos, Department of Physical Therapy, São Carlos, São Paulo, Brazil
| | | | - Camila Akemi Sakaguchi
- Appalachian State University, Department of Health, Leisure, and Exercise Science, NC, United States
| | - Aparecida Maria Catai
- Federal University of São Carlos, Department of Physical Therapy, São Carlos, São Paulo, Brazil
| | - Alberto Porta
- University of Milan, Department of Biomedical Sciences for Health, Milan, Italy; IRCCS Policlinico San Donato, Department of Cardiothoracic, Vascular Anesthesia and Intensive Care, San Donato Milanese, Milan, Italy
| |
Collapse
|
2
|
Liu H, Liang H, Yu X, Han Y, Wang G, Yan M, Wang W, Li S. A study on the immediate effects of enhanced external counterpulsation on physiological coupling. Front Neurosci 2023; 17:1197598. [PMID: 37351421 PMCID: PMC10282182 DOI: 10.3389/fnins.2023.1197598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 05/22/2023] [Indexed: 06/24/2023] Open
Abstract
Introduction Enhanced external counterpulsation (EECP) is a non-invasive assisted circulation technique for its clinical application in the rehabilitation and management of ischemic cardiovascular and cerebrovascular diseases, which has complex physiological and hemodynamic effects. However, the effects of EECP on the coupling of physiological systems are still unclear. We aimed to investigate the immediate effects of EECP on the coupling between integrated physiological systems such as cardiorespiratory and cardiovascular systems. Methods Based on a random sham-controlled design, simultaneous electrocardiography, photoplethysmography, bio-electrical impedance, and continuous hemodynamic data were recorded before, during and after two consecutive 30 min EECP in 41 healthy adults. Physiological coupling strength quantified by phase synchronization indexes (PSI), hemodynamic measurements and heart rate variability indices of 22 subjects (female/male: 10/12; age: 22.6 ± 2.1 years) receiving active EECP were calculated and compared with those of 19 sham control subjects (female/male: 7/12; age: 23.6 ± 2.5 years). Results Immediately after the two consecutive EECP interventions, the physiological coupling between respiratory and cardiovascular systems PSIRES-PTT (0.34 ± 0.14 vs. 0.49 ± 0.17, P = 0.002), the physiological coupling between cardiac and cardiovascular systems PSIIBI-PTT (0.41 ± 0.14 vs. 0.52 ± 0.16, P = 0.006) and the total physiological coupling PSItotal (1.21 ± 0.35 vs. 1.57 ± 0.49, P = 0.005) in the EECP group were significantly lower than those before the EECP intervention, while the physiological coupling indexes in the control group did not change significantly (P > 0.05). Conclusion Our study provides evidence that the PSI is altered by immediate EECP intervention. We speculate that the reduced PSI induced by EECP may be a marker of disturbed physiological coupling. This study provides a new method for exploring the mechanism of EECP action and may help to further optimize the EECP technique.
Collapse
Affiliation(s)
- Hongyun Liu
- Research Center for Biomedical Engineering, Medical Innovation Research Division, Chinese PLA General Hospital, Beijing, China
- Key Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Beijing, China
| | - Hui Liang
- Department of Hyperbaric Oxygen, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Xiaohua Yu
- Research Center for Biomedical Engineering, Medical Innovation Research Division, Chinese PLA General Hospital, Beijing, China
- Key Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Beijing, China
| | - Yi Han
- Research Center for Biomedical Engineering, Medical Innovation Research Division, Chinese PLA General Hospital, Beijing, China
- Key Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Beijing, China
| | - Guojing Wang
- Research Center for Biomedical Engineering, Medical Innovation Research Division, Chinese PLA General Hospital, Beijing, China
- Key Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Beijing, China
| | - Muyang Yan
- Department of Hyperbaric Oxygen, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Weidong Wang
- Research Center for Biomedical Engineering, Medical Innovation Research Division, Chinese PLA General Hospital, Beijing, China
- Key Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Beijing, China
| | - Shijun Li
- Department of Diagnostic Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
3
|
Centracchio J, Esposito D, Gargiulo GD, Andreozzi E. Changes in Forcecardiography Heartbeat Morphology Induced by Cardio-Respiratory Interactions. SENSORS (BASEL, SWITZERLAND) 2022; 22:9339. [PMID: 36502041 PMCID: PMC9736082 DOI: 10.3390/s22239339] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 11/24/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
The cardiac function is influenced by respiration. In particular, various parameters such as cardiac time intervals and the stroke volume are modulated by respiratory activity. It has long been recognized that cardio-respiratory interactions modify the morphology of cardio-mechanical signals, e.g., phonocardiogram, seismocardiogram (SCG), and ballistocardiogram. Forcecardiography (FCG) records the weak forces induced on the chest wall by the mechanical activity of the heart and lungs and relies on specific force sensors that are capable of monitoring respiration, infrasonic cardiac vibrations, and heart sounds, all simultaneously from a single site on the chest. This study addressed the changes in FCG heartbeat morphology caused by respiration. Two respiratory-modulated parameters were considered, namely the left ventricular ejection time (LVET) and a morphological similarity index (MSi) between heartbeats. The time trends of these parameters were extracted from FCG signals and further analyzed to evaluate their consistency within the respiratory cycle in order to assess their relationship with the breathing activity. The respiratory acts were localized in the time trends of the LVET and MSi and compared with a reference respiratory signal by computing the sensitivity and positive predictive value (PPV). In addition, the agreement between the inter-breath intervals estimated from the LVET and MSi and those estimated from the reference respiratory signal was assessed via linear regression and Bland-Altman analyses. The results of this study clearly showed a tight relationship between the respiratory activity and the considered respiratory-modulated parameters. Both the LVET and MSi exhibited cyclic time trends that remarkably matched the reference respiratory signal. In addition, they achieved a very high sensitivity and PPV (LVET: 94.7% and 95.7%, respectively; MSi: 99.3% and 95.3%, respectively). The linear regression analysis reported almost unit slopes for both the LVET (R2 = 0.86) and MSi (R2 = 0.97); the Bland-Altman analysis reported a non-significant bias for both the LVET and MSi as well as limits of agreement of ±1.68 s and ±0.771 s, respectively. In summary, the results obtained were substantially in line with previous findings on SCG signals, adding to the evidence that FCG and SCG signals share a similar information content.
Collapse
Affiliation(s)
- Jessica Centracchio
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, Italy
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, Italy
| | - Gaetano D. Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2751, Australia
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, Italy
| |
Collapse
|