1
|
Velho TR, Guerra N. The necessity of investigator-initiated trials in cardiothoracic surgery. Eur J Cardiothorac Surg 2023; 64:ezad292. [PMID: 37610357 DOI: 10.1093/ejcts/ezad292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 08/22/2023] [Indexed: 08/24/2023] Open
Affiliation(s)
- Tiago R Velho
- Department of Cardiothoracic Surgery, Hospital de Santa Maria, Centro Hospitalar Universitário Lisboa Norte EPE, Lisboa, Portugal
- Innate Immunity and Inflammation Laboratory, Instituto Gulbenkian de Ciência, Oeiras, Portugal
| | - Nuno Guerra
- Department of Cardiothoracic Surgery, Hospital de Santa Maria, Centro Hospitalar Universitário Lisboa Norte EPE, Lisboa, Portugal
| |
Collapse
|
2
|
Hatoum H, Ahn S, Lilly S, Maureira P, Crestanello J, Thourani VH, Dasi LP. Flow dynamics of surgical and transcatheter aortic valves: Past to present. JTCVS OPEN 2022; 9:43-56. [PMID: 36003460 PMCID: PMC9390780 DOI: 10.1016/j.xjon.2022.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 01/12/2022] [Indexed: 11/15/2022]
Affiliation(s)
- Hoda Hatoum
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Mich
- Health Research Institute, Center of Biocomputing and Digital Health and Institute of Computing and Cybernetics, Michigan Technological University, Houghton, Mich
- Center of Biocomputing and Digital Health, Michigan Technological University, Houghton, Mich
- Address for reprints: Hoda Hatoum, PhD, Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr, Houghton, MI 49931.
| | - Sunyoung Ahn
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Mich
| | - Scott Lilly
- Division of Cardiovascular Medicine, The Ohio State University, Columbus, Ohio
| | - Pablo Maureira
- Department of Cardiovascular Surgery, CHU de Nancy, Nancy, France
| | - Juan Crestanello
- Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minn
| | - Vinod H. Thourani
- Department of Cardiovascular Surgery, Marcus Valve Center, Piedmont Heart Institute, Atlanta, Ga
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga
| |
Collapse
|
3
|
Poly-2-methyl-2-oxazoline–modified bioprosthetic heart valve leaflets have enhanced biocompatibility and resist structural degeneration. Proc Natl Acad Sci U S A 2022; 119:2120694119. [PMID: 35131859 PMCID: PMC8833185 DOI: 10.1073/pnas.2120694119] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/04/2022] [Indexed: 12/26/2022] Open
Abstract
Bioprosthetic heart valves (BHV) fabricated from glutaraldehyde-fixed heterograft tissue, such as bovine pericardium (BP), are widely used for treating heart valve disease, a group of disorders that affects millions. Structural valve degeneration (SVD) of BHV due to both calcification and the accumulation of advanced glycation end products (AGE) with associated serum proteins limits durability. We hypothesized that BP modified with poly-2-methyl-2-oxazoline (POZ) to inhibit protein entry would demonstrate reduced accumulation of AGE and serum proteins, mitigating SVD. In vitro studies of POZ-modified BP demonstrated reduced accumulation of serum albumin and AGE. BP-POZ in vitro maintained collagen microarchitecture per two-photon microscopy despite AGE incubation, and in cell culture studies was associated with no change in tumor necrosis factor-α after exposure to AGE and activated macrophages. Comparing POZ and polyethylene glycol (PEG)–modified BP in vitro, BP-POZ was minimally affected by oxidative conditions, whereas BP-PEG was susceptible to oxidative deterioration. In juvenile rat subdermal implants, BP-POZ demonstrated reduced AGE formation and serum albumin infiltration, while calcification was not inhibited. However, BP-POZ rat subdermal implants with ethanol pretreatment demonstrated inhibition of both AGE accumulation and calcification. Ex vivo laminar flow studies with human blood demonstrated BP-POZ enhanced thromboresistance with reduced white blood cell accumulation. We conclude that SVD associated with AGE and serum protein accumulation can be mitigated through POZ functionalization that both enhances biocompatibility and facilitates ethanol pretreatment inhibition of BP calcification.
Collapse
|
4
|
Mid-term clinical and health-related quality of life outcomes for the Trifecta bioprosthesis. Indian J Thorac Cardiovasc Surg 2021; 37:496-505. [PMID: 34511755 DOI: 10.1007/s12055-021-01166-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/12/2021] [Accepted: 02/16/2021] [Indexed: 10/21/2022] Open
Abstract
Background The Trifecta valve has been reported to have excellent hemodynamics. Controversy exists on occurrence of patient-prosthesis mismatch (PPM) and data on mid-term outcome is sparse. Health-related quality of life (HRQoL) assessment for the Trifecta valve has not been reported before. The aim of this study was to report the mid-term clinical and HRQoL outcomes in patients undergoing Trifecta valve implantation at our institution. Methods In this prospective, observational study, patients undergoing an aortic valve replacement (AVR) using the Trifecta valve were included. Data collection was retrospective from prospectively collected institutional database. Clinical and echocardiographic data were collected prospectively during follow-up. Quality of life was assessed using the Short Form-36 (SF-36) questionnaire. Results Forty-seven patients were included in the study of which 9 (19%) were women. Isolated AVR was carried out in 33 (70%) patients. In-hospital mortality and 30-day mortality were 1 (2.1%) and 2 (4.2%), respectively. With a mean indexed effective orifice area (iEOA) 0.96 ± 0.1, none of the patients had severe PPM. Moderate PPM was seen in 19%. The mean follow-up was 3 ± 1.7 years. The 5-year survival estimate was 83.2% in the overall cohort, 81.4% in the isolated and 87.5% in the concomitant procedure group. Freedom from re-operation and structural valve degeneration at 5 years was 95.7% and 97.8%. The mean physical health composite was 69.24 ± 2 and the mean mental health composite was 69.7 ± 25, indicating excellent mental and physical well-being among patients. Conclusion The Trifecta valve provides satisfactory hemodynamics, survival and freedom from re-operation and excellent HRQoL at mid-term follow-up.
Collapse
|
5
|
Amirjamshidi H, Vidovich C, Goodman A, Knight PA. Early Outcomes of Isolated Aortic Valve Replacement Through Right Anterior Minithoracotomy Using the Latest-Generation Biological Prosthesis. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2020; 16:52-57. [PMID: 33337279 DOI: 10.1177/1556984520975889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
OBJECTIVE The aim of this study is to evaluate early and intermediate outcomes and hemodynamics of the latest-generation Trifecta valve implanted using right anterior minithoracotomy. METHODS We performed a single-center, retrospective, observational study including 175 individuals who underwent isolated minimally invasive aortic valve replacement with the latest-generation Trifecta valves through a right anterior minithoracotomy between January 2016 and January 2019. Exclusion criteria for follow-up echocardiographic study included concomitant procedures, conversion to median sternotomy, and nonsurvival during the index admission. Analyses addressed implantation safety, 30-day and intermediate-term survival and hemodynamic performance of the valves. RESULTS Overall, patients were followed with duration ranging from 0.5 to 3 years. Early (<30 days) mortality occurred in 2 patients (1.1%), and there were 9 (5.1%) late (>30 days) deaths. Early thromboembolic events and postoperative bleeding requiring reoperation occurred at a rate of 4.0% (n = 7) and 6.2% (n = 11), respectively. Overall in 175 patients who met inclusion criteria for the follow-up echocardiography study, mean gradients across all valve sizes were 41.3 ± 14.9 (standard deviation) mm Hg preoperatively and remained low at 7.2 ± 3.9 mm Hg with mean effective orifice area of 1.8 ± 0.5 cm2 on the last follow-up echo. There was 1 case of infective prosthetic endocarditis, which did not require valve explant. There were no reoperations due to valve-related problems during the study period. CONCLUSIONS This is the largest series reporting on outcomes of the latest-generation Trifecta valve implanted using right anterior minithoracotomy. Our results demonstrate that this valve can be safely implanted via a minimally invasive approach with excellent early and intermediate outcomes and hemodynamic performance.
Collapse
Affiliation(s)
- Hossein Amirjamshidi
- 6923 Division of Cardiac Surgery, University of Rochester Medical Center, NY, USA
| | - Courtney Vidovich
- 6923 Division of Cardiac Surgery, University of Rochester Medical Center, NY, USA
| | - Ariana Goodman
- 6923 Division of Cardiac Surgery, University of Rochester Medical Center, NY, USA
| | - Peter A Knight
- 6923 Division of Cardiac Surgery, University of Rochester Medical Center, NY, USA
| |
Collapse
|
6
|
Safety, efficacy, and hemodynamic performance of a stented bovine pericardial aortic valve bioprosthesis: Two-year analysis. J Thorac Cardiovasc Surg 2019; 160:371-381.e4. [PMID: 31590957 DOI: 10.1016/j.jtcvs.2019.07.132] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Revised: 06/14/2019] [Accepted: 07/08/2019] [Indexed: 11/22/2022]
Abstract
OBJECTIVES The study objectives were to evaluate the safety, efficacy, and hemodynamic performance of a novel stented bovine pericardial aortic valve bioprosthesis 2 years after implantation. METHODS The PERIcardial SurGical AOrtic Valve ReplacemeNT Pivotal Trial enrolled patients with symptomatic moderate/severe aortic stenosis or regurgitation at centers in Canada, Europe, and the United States. We report the outcomes and hemodynamic performance in patients with up to 2 years of follow-up. RESULTS A total of 1273 patients were enrolled, and 1110 underwent implantation. Among patients undergoing implantation, the mean age was 70.2 ± 8.9 years; 833 (75.0%) were male. Risk of mortality (Society of Thoracic Surgeons) was 2.0% ± 1.4%. At the time of analysis, 604 patients had completed the 2-year follow-up visit. Linearized late event rates were as follows: all death, 2.68%; valve-related death, 0.42%; valve thrombosis, 0.05%; endocarditis, 0.94%; thromboembolism, 1.68%; all hemorrhage, 2.94%; major hemorrhage, 1.99%; all paravalvular leak, 0.26%; and major paravalvular leak, 0.05% per patient-year. Mean 2-year aortic gradient and effective orifice area were 13.4 ± 5.0 mm Hg and 1.5 ± 0.37 cm2, respectively. Moderate and severe prosthesis-patient mismatch were observed in 43.5% and 34.8% of patients at 2 years, respectively. Improvement in New York Heart Association class compared with baseline was observed in 73.0% with moderate mismatch and 74.1% with severe mismatch. CONCLUSIONS The Avalus (Medtronic, Minneapolis, Minn) bovine pericardial valve demonstrates good clinical and safety outcomes at 2 years. Hemodynamic performance shows mean gradients comparable to currently available bovine pericardial aortic valves. There was no clinical impact of moderate to severe mismatch at 2 years. Further follow-up is required to evaluate midterm to long-term clinical outcome.
Collapse
|
7
|
Nardi P, Pisano C, Bertoldo F, Vacirca SR, Greci M, Bassano C, Scafuri A, Pellegrino A, Ruvolo G. Clinical outcome and hemodynamic performance of St. Jude Trifecta aortic prosthesis: short-term follow-up and risk factors analysis. J Thorac Dis 2019; 11:1465-1474. [PMID: 31179089 PMCID: PMC6531685 DOI: 10.21037/jtd.2019.03.41] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 02/25/2019] [Indexed: 11/06/2022]
Abstract
BACKGROUND We retrospectively analysed the short-term outcome of the third-generation St. Jude Trifecta aortic prosthesis. METHODS Between December 2014 and December 2017, 177 patients (mean age 75.1±6.8 years, 95 males, 82 females) underwent aortic valve replacement with a St. Jude Trifecta aortic prosthesis and were followed up to 27±9 months. Preoperatively 92 patients (52.0%) were in NYHA class III-IV, EuroSCORE II was 3.2%±2.1%. RESULTS Trifecta sizes implanted were 19 mm (n=46) (26%), 21 mm (n=69) (39%), 23 mm (n=46) (26%), 25 mm (n=16) (9%). Concomitant coronary artery bypass grafting was performed in 60 patients (34.0%). Operative mortality was 3.4% (1.7% for isolated aortic valve replacement versus 6.7% for combined aortic valve replacement and coronary artery bypass grafting) (P=0.084). The only independent predictor of mortality was the need for the mechanical ventilation greater than 24 hours (P=0.037); recently occurring myocardial infarction was risk factor for mortality at the univariate analysis only (P=0.013). Three-year survival was 84%±6%, freedom from cardiac death 98%±1%, freedom from prosthetic endocarditis 97%±1%. No thromboembolisms or structural valve degeneration were observed. Patient-prosthesis mismatch (PPM) was absent in 126 patients (71.2%), mild-to-moderate in 32 (18.1%), moderate in 19 (10.7%), severe in no any patient. Follow-up echocardiography showed an average mean and peak trans-aortic valve gradients reduction more than 70% in comparison with preoperative value (P<0.0001), and a significant regression of left ventricular hypertrophy (P<0.0001). Moderate PPM did not negatively affect survival. Concomitant severe coronary artery disease was found as an independent predictor of reduced survival (72%±12% versus 86%±6%) (P=0.015). CONCLUSIONS Trifecta aortic prosthesis seems to provide very favourable clinical outcome and hemodynamic performance. At three years, survival was negatively affected by severe coronary artery disease detected at the time of operation. During short-term follow-up, no early structural valve degeneration was been observed. Due to low incidence of PPM and low peak and mean trans-prosthetic aortic valve gradients, third generation Trifecta aortic prosthesis should be considered as one of the best options in the setting of the aortic valve replacement surgery. However, a long-term follow-up is mandatory to confirm the early promising data.
Collapse
Affiliation(s)
- Paolo Nardi
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| | - Calogera Pisano
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| | - Fabio Bertoldo
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| | - Sara Rita Vacirca
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| | - Monica Greci
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| | - Carlo Bassano
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| | - Antonio Scafuri
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| | | | - Giovanni Ruvolo
- Cardiac Surgery Division, Tor Vergata University Hospital, Rome, Italy
| |
Collapse
|
8
|
Amorim PA, Diab M, Walther M, Färber G, Hagendorff A, Bonow RO, Doenst T. Limitations in the Assessment of Prosthesis-Patient Mismatch. Thorac Cardiovasc Surg 2019; 68:550-556. [DOI: 10.1055/s-0038-1676814] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Abstract
Background Prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR) may affect survival but data are conflicting. It is assessed by relating effective orifice area (EOA) to body surface area (EOAi). EOA is patient-specific as the result of flow-velocity times area at the individual patient's outflow tract levels (LVOTA) divided by trans-prosthetic flow velocity. However, some studies use projected EOAs (i.e., valve size associated EOAs from other patient populations) to assess how PPM affects outcome.
Methods We analyzed 76 studies addressing hemodynamic outcome and/or mortality after bioprosthetic AVR.
Results In 48 studies, projected or measured EOA for calculation of EOAi and PPM assessment was used (of which 25 demonstrated an effect on survival). We identified 28 additional studies providing measured EOA values and the corresponding Bernoulli's pressure gradients after AVR. Despite EOA being a patient-specific parameter, 77% of studies assessing a PPM impact on survival used projected EOAs. The 28 studies are providing measured EOA values and the corresponding Bernoulli's pressure gradients in patients after AVR showed a highly significant, linear relationship between EOA and Bernoulli's gradient. Considering this relationship, it is surprising that relating EOA to body surface area (BSA) (EOAi) is standard but relating pressure gradients to BSA is not.
Conclusion We conclude that the majority of studies assessing PPM have used false assumptions because EOA is a patient-specific parameter and cannot be transferred to other patients. In addition, the use of EOAi to assess PPM may not be appropriate and could explain the inconsistent relation between PPM and survival in previous studies.
Collapse
Affiliation(s)
- Paulo A. Amorim
- Department of Cardiothoracic Surgery, Friedrich Schiller University Jena, Jena, Germany
| | - Mahmoud Diab
- Department of Cardiothoracic Surgery, Friedrich Schiller University Jena, Jena, Germany
| | - Mario Walther
- Department of Basic Sciences, University of Applied Sciences Jena, Jena, Germany
| | - Gloria Färber
- Department of Cardiothoracic Surgery, Friedrich Schiller University Jena, Jena, Germany
| | - Andreas Hagendorff
- Department of Internal Medicine, University Hospital Leipzig, Leipzig, Germany
| | - Robert O. Bonow
- Division of Cardiology, Department of Medicine, Northwestern University Feinberg School of Medicine Chicago, Chicago, Germany
| | - Torsten Doenst
- Department of Cardiothoracic Surgery, Friedrich Schiller University Jena, Jena, Germany
| |
Collapse
|
9
|
Fiedler AG, Tolis G. Surgical Treatment of Valvular Heart Disease: Overview of Mechanical and Tissue Prostheses, Advantages, Disadvantages, and Implications for Clinical Use. CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE 2018; 20:7. [DOI: 10.1007/s11936-018-0601-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
10
|
Raimundo R, Moreira S, Saraiva F, Cerqueira RJ, Teixeira P, Salgueiro E, Lourenço A, Amorim MJ, Almeida J, Pinho P, Leite-Moreira AF. Early and mid-term haemodynamic performance and clinical outcomes of St. Jude Medical Trifecta™ valve. J Thorac Dis 2018; 10:889-898. [PMID: 29607162 DOI: 10.21037/jtd.2018.01.15] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background New models of aortic bioprostheses have proven excellent early haemodynamic profile, but their mid and long-term performance warrants further systematic assessment. The aim of this study is to report clinical and haemodynamic performance of St. Jude Medical Trifecta bioprosthesis during 5 years of implantation. Methods We performed a single centre, retrospective, observational and descriptive study including all 556 individuals who underwent aortic valve replacement (AVR) with the Trifecta bioprosthesis (between July of 2011 and June of 2016). Survival and re-intervention were censored in February 2017. Postoperative ambulatory echocardiographic data was available for 490 patients. A complete clinical follow-up was available in 463 individuals (mean follow-up time, 27±17 months). Results In our sample the mean age was 73±9 years, 57.6% were male and median European System for Cardiac Operative Risk Evaluation (EuroSCORE) II was 2.9 (interquartile range, 1.6-5.8). There were 301 (54.1%) combined procedures, mostly coronary artery bypass grafting in 170 (30.6%). Overall 30-days mortality was 5.4% (n=30) and cumulative survival at 5-years was 72.3%. There were 23 (4.3%) permanent pacemaker implantations. During follow-up, 5 (0.9%) patients presented non-structural valve dysfunction (NSVD) and 4 (0.8%) underwent reoperation due to prosthesis endocarditis. At the first ambulatory evaluation transvalvular mean gradient and effective orifice area (EOA) were 10.9±4.1 mmHg and 2.0±0.5 cm2, respectively. Severe patient-prosthesis mismatch (PPM) was observed in 5 (1.1%) individuals and moderate in 52 (11.3%). Conclusions In a "real-world" clinical setting, our findings support the good overall mid-term haemodynamic and safety profile of the Trifecta bioprosthesis.
Collapse
Affiliation(s)
- Renata Raimundo
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal
| | - Soraia Moreira
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal
| | - Francisca Saraiva
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal
| | - Rui J Cerqueira
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal.,Serviço de Cirurgia Cardiotorácica, Centro Hospitalar de São João, Porto, Portugal
| | - Pedro Teixeira
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal
| | - Elson Salgueiro
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal.,Serviço de Cirurgia Cardiotorácica, Centro Hospitalar de São João, Porto, Portugal
| | - André Lourenço
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal.,Serviço de Anestesiologia, Centro Hospitalar de São João, Porto, Portugal
| | - Mário J Amorim
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal.,Serviço de Cirurgia Cardiotorácica, Centro Hospitalar de São João, Porto, Portugal
| | - Jorge Almeida
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal.,Serviço de Cirurgia Cardiotorácica, Centro Hospitalar de São João, Porto, Portugal
| | - Paulo Pinho
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal.,Serviço de Cirurgia Cardiotorácica, Centro Hospitalar de São João, Porto, Portugal
| | - Adelino F Leite-Moreira
- Departamento de Cirurgia e Fisiologia, Faculdade de Medicina da Universidade do Porto, Porto, Portugal.,Serviço de Cirurgia Cardiotorácica, Centro Hospitalar de São João, Porto, Portugal
| |
Collapse
|
11
|
Gonzalez-Lopez D, Faerber G, Diab M, Amorim P, Zeynalov N, Doenst T. Replica sizing strategy for aortic valve replacement improves haemodynamic outcome of the epic supra valve. Interact Cardiovasc Thorac Surg 2017; 25:509-512. [DOI: 10.1093/icvts/ivx234] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Accepted: 05/29/2017] [Indexed: 11/14/2022] Open
|