1
|
Lecchini-Visintini A, Zwanenburg JJM, Wen Q, Nicholls JK, Desmidt T, Catheline S, Minhas JS, Robba C, Dvoriashyna M, Vallet A, Bamber J, Kurt M, Chung EML, Holdsworth S, Payne SJ. The pulsing brain: state of the art and an interdisciplinary perspective. Interface Focus 2025; 15:20240058. [PMID: 40191028 PMCID: PMC11969196 DOI: 10.1098/rsfs.2024.0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2024] [Revised: 02/11/2025] [Accepted: 02/24/2025] [Indexed: 04/09/2025] Open
Abstract
Understanding the pulsing dynamics of tissue and fluids in the intracranial environment is an evolving research theme aimed at gaining new insights into brain physiology and disease progression. This article provides an overview of related research in magnetic resonance imaging, ultrasound medical diagnostics and mathematical modelling of biological tissues and fluids. It highlights recent developments, illustrates current research goals and emphasizes the importance of collaboration between these fields.
Collapse
Affiliation(s)
| | - Jacobus J. M. Zwanenburg
- Translational Neuroimaging Group, Center for Image Sciences, UMC Utrecht, Utrecht, The Netherlands
| | - Qiuting Wen
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Jennifer K. Nicholls
- Department of Cardiovascular Sciences, Cerebral Haemodynamics in Ageing and Stroke Medicine (CHiASM) Research Group, University of Leicester, Leicester, UK
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | | | - Jatinder S. Minhas
- Department of Cardiovascular Sciences, Cerebral Haemodynamics in Ageing and Stroke Medicine (CHiASM) Research Group, University of Leicester, Leicester, UK
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Chiara Robba
- Department of Surgical Sciences and Integrated Diagnosis, University of Genoa, Genova, Italy
- IRCCS Policlinico San Martino, Genova, Italy
| | - Mariia Dvoriashyna
- School of Mathematics and Maxwell Institute for Mathematical Sciences, University of Edinburgh, Edinburgh, UK
| | - Alexandra Vallet
- Ecole nationale supérieure des Mines de Saint-Étienne, INSERM U 1059 Sainbiose, Saint-Étienne, France
| | - Jeffrey Bamber
- Institute of Cancer Research, London, UK
- Royal Marsden NHS Foundation Trust, London, UK
| | - Mehmet Kurt
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Emma M. L. Chung
- School of Life Course and Population Sciences, King's College London, London, UK
| | - Samantha Holdsworth
- Mātai Medical Research Institute, Tairāwhiti-Gisborne, New Zealand
- Faculty of Medical and Health Sciences & Centre for Brain Research, University of Auckland, Auckland, New Zealand
| | - Stephen J. Payne
- Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
2
|
Sabeti S, Larson NB, Boughey JC, Stan DL, Solanki MH, Fazzio RT, Fatemi M, Alizad A. Ultrasound-based quantitative microvasculature imaging for early prediction of response to neoadjuvant chemotherapy in patients with breast cancer. Breast Cancer Res 2025; 27:24. [PMID: 39962614 PMCID: PMC11834208 DOI: 10.1186/s13058-025-01978-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2024] [Accepted: 02/06/2025] [Indexed: 02/20/2025] Open
Abstract
BACKGROUND Angiogenic activity of cancerous breast tumors can be impacted by neoadjuvant chemotherapy (NAC), thus potentially serving as a marker for response monitoring. While different imaging modalities can aid in evaluation of tumoral vascular changes, ultrasound-based approaches are particularly suitable for clinical use due to their availability and noninvasiveness. In this paper, we make use of quantitative high-definition microvasculature imaging (qHDMI) based on contrast-free ultrasound for assessment of NAC response in breast cancer patients. METHODS Patients with invasive breast cancer recommended treatment with NAC were included in the study and ultrafast ultrasound data were acquired at pre-NAC, mid-NAC, and post-NAC time points. Data acquisitions also took place at two additional timepoints - at two and four weeks after NAC initiation in a subset of patients. Ultrasound data frames were processed within the qHDMI framework to visualize the microvasculature in and around the breast tumors. Morphological analyses on the microvasculature structure were performed to obtain 12 qHDMI biomarkers. Pathology from surgery classified response using residual cancer burden (RCB) and was used to designate patients as responders (RCB 0/I) and non-responders (RCB II/III). Distributions of imaging biomarkers across the two groups were analyzed using Wilcoxon rank-sum test. The trajectories of biomarker values over time were investigated and linear mixed effects models were used to evaluate interactions between time and group for each biomarker. RESULTS Of the 53 patients included in the study, 32 (60%) were responders based on their RCB status. The results of linear mixed effects model analysis showed statistically significant interactions between group and time in six out of the 12 qHDMI biomarkers, indicating differences in trends of microvascular morphological features by responder status. In particular, vessel density (p-value: 0.023), maximum tortuosity (p-value: 0.049), maximum diameter (p-value: 0.002), fractal dimension (p-value: 0.002), mean Murray's deviation (p-value: 0.034), and maximum Murray's deviation (p-value: 0.022) exhibited significantly different trends based on responder status. CONCLUSIONS We observed microvasculature changes in response to NAC in breast cancer patients using qHDMI as an objective and quantitative contrast-free ultrasound framework. These finding suggest qHDMI may be effective in identifying early response to NAC.
Collapse
Affiliation(s)
- Soroosh Sabeti
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Nicholas B Larson
- Department of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Judy C Boughey
- Division of Breast and Melanoma Surgical Oncology, Department of Surgery, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Daniela L Stan
- Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Malvika H Solanki
- Department of Laboratory Medicine and Pathology, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Robert T Fazzio
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 1st Street SW, Rochester, MN, 55905, USA
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Azra Alizad
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA.
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 1st Street SW, Rochester, MN, 55905, USA.
| |
Collapse
|
3
|
Nyayapathi N, Zheng E, Zhou Q, Doyley M, Xia J. Dual-modal Photoacoustic and Ultrasound Imaging: from preclinical to clinical applications. FRONTIERS IN PHOTONICS 2024; 5:1359784. [PMID: 39185248 PMCID: PMC11343488 DOI: 10.3389/fphot.2024.1359784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
Photoacoustic imaging is a novel biomedical imaging modality that has emerged over the recent decades. Due to the conversion of optical energy into the acoustic wave, photoacoustic imaging offers high-resolution imaging in depth beyond the optical diffusion limit. Photoacoustic imaging is frequently used in conjunction with ultrasound as a hybrid modality. The combination enables the acquisition of both optical and acoustic contrasts of tissue, providing functional, structural, molecular, and vascular information within the same field of view. In this review, we first described the principles of various photoacoustic and ultrasound imaging techniques and then classified the dual-modal imaging systems based on their preclinical and clinical imaging applications. The advantages of dual-modal imaging were thoroughly analyzed. Finally, the review ends with a critical discussion of existing developments and a look toward the future.
Collapse
Affiliation(s)
- Nikhila Nyayapathi
- Electrical and Computer Engineering, University of Rochester, Rochester, New York, 14627
| | - Emily Zheng
- Department of Biomedical Engineering, University at Buffalo, Buffalo, New York, 14226
| | - Qifa Zhou
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90007
| | - Marvin Doyley
- Electrical and Computer Engineering, University of Rochester, Rochester, New York, 14627
| | - Jun Xia
- Department of Biomedical Engineering, University at Buffalo, Buffalo, New York, 14226
| |
Collapse
|
4
|
Adusei SA, Sabeti S, Larson NB, Dalvin LA, Fatemi M, Alizad A. Quantitative Biomarkers Derived from a Novel, Contrast-Free Ultrasound, High-Definition Microvessel Imaging for Differentiating Choroidal Tumors. Cancers (Basel) 2024; 16:395. [PMID: 38254884 PMCID: PMC10814019 DOI: 10.3390/cancers16020395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 12/30/2023] [Accepted: 01/15/2024] [Indexed: 01/24/2024] Open
Abstract
Angiogenesis has an essential role in the de novo evolution of choroidal melanoma as well as choroidal nevus transformation into melanoma. Differentiating early-stage melanoma from nevus is of high clinical importance; thus, imaging techniques that provide objective information regarding tumor microvasculature structures could aid accurate early detection. Herein, we investigated the feasibility of quantitative high-definition microvessel imaging (qHDMI) for differentiation of choroidal tumors in humans. This new ultrasound-based technique encompasses a series of morphological filtering and vessel enhancement techniques, enabling the visualization of tumor microvessels as small as 150 microns and extracting vessel morphological features as new tumor biomarkers. Distributional differences between the malignant melanomas and benign nevi were tested on 37 patients with choroidal tumors using a non-parametric Wilcoxon rank-sum test, and statistical significance was declared for biomarkers with p-values < 0.05. The ocular oncology diagnosis was choroidal melanoma (malignant) in 21 and choroidal nevus (benign) in 15 patients. The mean thickness of benign and malignant masses was 1.70 ± 0.40 mm and 3.81 ± 2.63 mm, respectively. Six HDMI biomarkers, including number of vessel segments (p = 0.003), number of branch points (p = 0.003), vessel density (p = 0.03), maximum tortuosity (p = 0.001), microvessel fractal dimension (p = 0.002), and maximum diameter (p = 0.003) exhibited significant distributional differences between the two groups. Contrast-free HDMI provided noninvasive imaging and quantification of microvessels of choroidal tumors. The results of this pilot study indicate the potential use of qHDMI as a complementary tool for characterization of small ocular tumors and early detection of choroidal melanoma.
Collapse
Affiliation(s)
- Shaheeda A. Adusei
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, 200 1st St. SW, Rochester, MN 55905, USA (M.F.)
| | - Soroosh Sabeti
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, 200 1st St. SW, Rochester, MN 55905, USA (M.F.)
| | - Nicholas B. Larson
- Department of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, 200 1st St. SW, Rochester, MN 55905, USA
| | - Lauren A. Dalvin
- Department of Ophthalmology, Mayo Clinic College of Medicine and Science, 200 1st St. SW, Rochester, MN 55905, USA
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, 200 1st St. SW, Rochester, MN 55905, USA (M.F.)
| | - Azra Alizad
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, 200 1st St. SW, Rochester, MN 55905, USA (M.F.)
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 1st St. SW, Rochester, MN 55905, USA
| |
Collapse
|
5
|
Luo R, Zhang Y, Jiang W, Wang Y, Luo Y. Value of micro-flow imaging and high-definition micro-flow imaging in differentiating malignant and benign breast lesions. Clin Radiol 2024; 79:e48-e56. [PMID: 37932209 DOI: 10.1016/j.crad.2023.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Revised: 09/03/2023] [Accepted: 10/08/2023] [Indexed: 11/08/2023]
Abstract
AIM To evaluate the value of non-contrast micro-flow imaging (MFI) and high-definition micro-flow imaging (HD-MFI) in differentiating malignant and benign breast lesions. MATERIALS AND METHODS One hundred and thirty-three patients with 138 breast lesions (80 benign and 58 malignant lesions) were examined using colour Doppler flow imaging (CDFI), MFI, and HD-MFI before biopsy, with blood flow signals graded into four types (grade 0, 1, 2, and 3) and penetrating vessels evaluated. The micro-vascular patterns of MFI and HD-MFI were evaluated and classified into five patterns: avascular, line-like, tree-like, root hair-like, and crab claw-like pattern. The diagnostic efficiency of micro-vascular patterns was analysed. Moreover, ultrasound Breast Imaging Reporting and Data System (BI-RADS) 4A lesions were also re-assessed according to the micro-vascular patterns of MFI or HD-MFI. RESULTS The capability of detecting blood flow and penetrating vessels from high to low was HD-MFI, MFI, and CDFI, respectively (p<0.05). Rich blood flow signals, penetrating vessels, and root hair-like or crab claw-like pattern were more likely in malignant breast lesions, while few blood flow signals, tree-like pattern were mostly in benign lesions (p<0.05). The diagnostic efficiency of HD-MFI and MFI were higher than CDFI (p>0.05). MFI could reduce unnecessary biopsy of 52 US BI-RADS 4A lesions but with two malignancies missed, while 56 ultrasound BI-RADS 4A lesions could be downgraded by HD-MFI with none malignancies missed. CONCLUSIONS MFI and HD-MFI can detect more blood flow in breast lesions than CDFI, and could help distinguish benign and malignant breast lesions. HD-MFI could reduce the unnecessary biopsy of US BI-RADS 4A lesions without missed malignancy.
Collapse
Affiliation(s)
- R Luo
- Medical College, Yangzhou University, Yangzhou, Jiangsu, China; Department of Ultrasound, Division of First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Y Zhang
- Department of Ultrasound, Division of First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - W Jiang
- Department of Ultrasound, Division of First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Y Wang
- Department of Ultrasound, Division of First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Y Luo
- Department of Ultrasound, Division of First Medical Center, Chinese PLA General Hospital, Beijing, China.
| |
Collapse
|
6
|
Li J, Wei C, Ma X, Ying T, Sun D, Zheng Y. Maximum intensity projection based on high frame rate contrast-enhanced ultrasound for the differentiation of breast tumors. Front Oncol 2023; 13:1274716. [PMID: 37965464 PMCID: PMC10642959 DOI: 10.3389/fonc.2023.1274716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 10/16/2023] [Indexed: 11/16/2023] Open
Abstract
Objective We explored the role of maximum intensity projection (MIP) based on high frame rate contrast-enhanced ultrasound (H-CEUS) for the differentiation of breast tumors. Methods MIP imaging was performed in patients with breast tumors who underwent H-CEUS examinations. The microvasculature morphology of breast tumors was assessed. The receiver operating characteristic curve was plotted to evaluate the diagnostic performance of MIP. Results Forty-three breast tumors were finally analyzed, consisting of 19 benign and 24 malignant tumors. For the ≤30-s and >30-s phases, dot-, line-, or branch-like patterns were significantly more common in benign tumors. A tree-like pattern was only present in the benign tumors. A crab claw-like pattern was significantly more common in the malignant tumors. Among the tumors with crab claw-like patterns, three cases of malignant tumors had multiple parallel small spiculated vessels. There were significant differences in the microvasculature morphology for the ≤30-s and >30-s phases between the benign and malignant tumors (all p < 0.001). The area under the curve, sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the ≤30-s phase were all higher than those of the >30-s phase for the classification of breast tumors. Conclusion MIP based on H-CEUS can be used for the differentiation of breast tumors, and the ≤30-s phase had a better diagnostic value. Multiple parallel small spiculated vessels were a new finding, which could provide new insight for the subsequent study of breast tumors.
Collapse
Affiliation(s)
| | | | | | - Tao Ying
- Department of Ultrasound in Medicine, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Di Sun
- Department of Ultrasound in Medicine, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yuanyi Zheng
- Department of Ultrasound in Medicine, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
7
|
Tsarouchi MI, Hoxhaj A, Mann RM. New Approaches and Recommendations for Risk-Adapted Breast Cancer Screening. J Magn Reson Imaging 2023; 58:987-1010. [PMID: 37040474 DOI: 10.1002/jmri.28731] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/23/2023] [Accepted: 03/24/2023] [Indexed: 04/13/2023] Open
Abstract
Population-based breast cancer screening using mammography as the gold standard imaging modality has been in clinical practice for over 40 years. However, the limitations of mammography in terms of sensitivity and high false-positive rates, particularly in high-risk women, challenge the indiscriminate nature of population-based screening. Additionally, in light of expanding research on new breast cancer risk factors, there is a growing consensus that breast cancer screening should move toward a risk-adapted approach. Recent advancements in breast imaging technology, including contrast material-enhanced mammography (CEM), ultrasound (US) (automated-breast US, Doppler, elastography US), and especially magnetic resonance imaging (MRI) (abbreviated, ultrafast, and contrast-agent free), may provide new opportunities for risk-adapted personalized screening strategies. Moreover, the integration of artificial intelligence and radiomics techniques has the potential to enhance the performance of risk-adapted screening. This review article summarizes the current evidence and challenges in breast cancer screening and highlights potential future perspectives for various imaging techniques in a risk-adapted breast cancer screening approach. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: Stage 5.
Collapse
Affiliation(s)
- Marialena I Tsarouchi
- Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Nijmegen, the Netherlands
- Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands
| | - Alma Hoxhaj
- Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Nijmegen, the Netherlands
- Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands
| | - Ritse M Mann
- Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Nijmegen, the Netherlands
- Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands
| |
Collapse
|
8
|
Adusei S, Ternifi R, Fatemi M, Alizad A. Custom-made flow phantoms for quantitative ultrasound microvessel imaging. ULTRASONICS 2023; 134:107092. [PMID: 37364357 PMCID: PMC10530522 DOI: 10.1016/j.ultras.2023.107092] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 06/19/2023] [Accepted: 06/21/2023] [Indexed: 06/28/2023]
Abstract
Morphologically realistic flow phantoms are essential experimental tools for quantitative ultrasound-based microvessel imaging. As new quantitative flow imaging tools are developed, the need for more complex vessel-mimicking phantoms is indisputable. In this article, we propose a method for fabricating phantoms with sub-millimeter channels consisting of branches and curvatures in various shapes and sizes suitable for quantifying vessel morphological features. We used different tissue-mimicking materials (TMMs) compatible with ultrasound imaging as the base and metal wires of different diameters (0.15-1.25 mm) to create wall-less channels. The TMMs used are silicone rubber, plastisol, conventional gelatin, and medical gelatin. Mother channels in these phantoms were made in diameters of 1.25 mm or 0.3 mm and the daughter channels in diameters 0.3 mm or 0.15 mm. Bifurcations were created by soldering wires together at branch points. Quantitative parameters were assessed, and accuracy of measurements from the ground truth were determined. Channel diameters were seen to have increased (76-270%) compared to the initial state in the power Doppler images, partly due to blood mimicking fluid pressure. Amongst the microflow phantoms made from the different TMMs, the medical gelatin phantom was selected as the best option for microflow imaging, fulfilling the objective of being easy to fabricate with high transmittance while having a speed of sound and acoustic attenuation close to human tissue. A flow velocity of 0.85 ± 0.01 mm/s, comparable to physiological flow velocity was observed in the smallest diameter phantom (medical gelatin branch) presented here. We successfully constructed more complex geometries, including tortuous and multibranch channels using the medical gelatin as the TMM. We anticipate this will create new avenues for validating quantitative ultrasound microvessel imaging techniques.
Collapse
Affiliation(s)
- Shaheeda Adusei
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Redouane Ternifi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Azra Alizad
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA.
| |
Collapse
|
9
|
Ferroni G, Sabeti S, Abdus-Shakur T, Scalise L, Carter JM, Fazzio RT, Larson NB, Fatemi M, Alizad A. Noninvasive prediction of axillary lymph node breast cancer metastasis using morphometric analysis of nodal tumor microvessels in a contrast-free ultrasound approach. Breast Cancer Res 2023; 25:65. [PMID: 37296471 PMCID: PMC10257266 DOI: 10.1186/s13058-023-01670-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Accepted: 06/02/2023] [Indexed: 06/12/2023] Open
Abstract
PURPOSE Changes in microcirculation of axillary lymph nodes (ALNs) may indicate metastasis. Reliable noninvasive imaging technique to quantify such variations is lacking. We aim to develop and investigate a contrast-free ultrasound quantitative microvasculature imaging technique for detection of metastatic ALN in vivo. EXPERIMENTAL DESIGN The proposed ultrasound-based technique, high-definition microvasculature imaging (HDMI) provides superb images of tumor microvasculature at sub-millimeter size scales and enables quantitative analysis of microvessels structures. We evaluated the new HDMI technique on 68 breast cancer patients with ultrasound-identified suspicious ipsilateral axillary lymph nodes recommended for fine needle aspiration biopsy (FNAB). HDMI was conducted before the FNAB and vessel morphological features were extracted, analyzed, and the results were correlated with the histopathology. RESULTS Out of 15 evaluated quantitative HDMI biomarkers, 11 were significantly different in metastatic and reactive ALNs (10 with P << 0.01 and one with 0.01 < P < 0.05). We further showed that through analysis of these biomarkers, a predictive model trained on HDMI biomarkers combined with clinical information (i.e., age, node size, cortical thickness, and BI-RADS score) could identify metastatic lymph nodes with an area under the curve of 0.9 (95% CI [0.82,0.98]), sensitivity of 90%, and specificity of 88%. CONCLUSIONS The promising results of our morphometric analysis of HDMI on ALNs offer a new means of detecting lymph node metastasis when used as a complementary imaging tool to conventional ultrasound. The fact that it does not require injection of contrast agents simplifies its use in routine clinical practice.
Collapse
Affiliation(s)
- Giulia Ferroni
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Soroosh Sabeti
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Tasneem Abdus-Shakur
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 1st. St. SW, Rochester, MN, 55905, USA
| | - Lorenzo Scalise
- Department of Industrial Engineering and Mathematical Science, Marche Polytechnic University, 60131, Ancona, Italy
| | - Jodi M Carter
- Department of Laboratory Medicine and Pathology, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB, Canada
| | - Robert T Fazzio
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 1st. St. SW, Rochester, MN, 55905, USA
| | - Nicholas B Larson
- Department of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Azra Alizad
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA.
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 1st. St. SW, Rochester, MN, 55905, USA.
| |
Collapse
|
10
|
Kurti M, Sabeti S, Robinson KA, Scalise L, Larson NB, Fatemi M, Alizad A. Quantitative Biomarkers Derived from a Novel Contrast-Free Ultrasound High-Definition Microvessel Imaging for Distinguishing Thyroid Nodules. Cancers (Basel) 2023; 15:cancers15061888. [PMID: 36980774 PMCID: PMC10046818 DOI: 10.3390/cancers15061888] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 03/09/2023] [Accepted: 03/19/2023] [Indexed: 03/30/2023] Open
Abstract
Low specificity in current ultrasound modalities for thyroid cancer detection necessitates the development of new imaging modalities for optimal characterization of thyroid nodules. Herein, the quantitative biomarkers of a new high-definition microvessel imaging (HDMI) were evaluated for discrimination of benign from malignant thyroid nodules. Without the help of contrast agents, this new ultrasound-based quantitative technique utilizes processing methods including clutter filtering, denoising, vessel enhancement filtering, morphological filtering, and vessel segmentation to resolve tumor microvessels at size scales of a few hundred microns and enables the extraction of vessel morphological features as new tumor biomarkers. We evaluated quantitative HDMI on 92 patients with 92 thyroid nodules identified in ultrasound. A total of 12 biomarkers derived from vessel morphological parameters were associated with pathology results. Using the Wilcoxon rank-sum test, six of the twelve biomarkers were significantly different in distribution between the malignant and benign nodules (all p < 0.01). A support vector machine (SVM)-based classification model was trained on these six biomarkers, and the receiver operating characteristic curve (ROC) showed an area under the curve (AUC) of 0.9005 (95% CI: [0.8279,0.9732]) with sensitivity, specificity, and accuracy of 0.7778, 0.9474, and 0.8929, respectively. When additional clinical data, namely TI-RADS, age, and nodule size were added to the features, model performance reached an AUC of 0.9044 (95% CI: [0.8331,0.9757]) with sensitivity, specificity, and accuracy of 0.8750, 0.8235, and 0.8400, respectively. Our findings suggest that tumor vessel morphological features may improve the characterization of thyroid nodules.
Collapse
Affiliation(s)
- Melisa Kurti
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Soroosh Sabeti
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Kathryn A Robinson
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Lorenzo Scalise
- Department of Industrial Engineering and Mathematical Science, Polytechnic University of Marchedelle Marche, 60131 Ancona, Italy
| | - Nicholas B Larson
- Department of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Azra Alizad
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| |
Collapse
|
11
|
Sabeti S, Ternifi R, Larson NB, Olson MC, Atwell TD, Fatemi M, Alizad A. Morphometric analysis of tumor microvessels for detection of hepatocellular carcinoma using contrast-free ultrasound imaging: A feasibility study. Front Oncol 2023; 13:1121664. [PMID: 37124492 PMCID: PMC10134399 DOI: 10.3389/fonc.2023.1121664] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 03/21/2023] [Indexed: 05/02/2023] Open
Abstract
Introduction A contrast-free ultrasound microvasculature imaging technique was evaluated in this study to determine whether extracting morphological features of the vascular networks in hepatic lesions can be beneficial in differentiating benign and malignant tumors (hepatocellular carcinoma (HCC) in particular). Methods A total of 29 lesions from 22 patients were included in this work. A post-processing algorithm consisting of clutter filtering, denoising, and vessel enhancement steps was implemented on ultrasound data to visualize microvessel structures. These structures were then further characterized and quantified through additional image processing. A total of nine morphological metrics were examined to compare different groups of lesions. A two-sided Wilcoxon rank sum test was used for statistical analysis. Results In the malignant versus benign comparison, six of the metrics manifested statistical significance. Comparing only HCC cases with the benign, only three of the metrics were significantly different. No statistically significant distinction was observed between different malignancies (HCC versus cholangiocarcinoma and metastatic adenocarcinoma) for any of the metrics. Discussion Obtained results suggest that designing predictive models based on such morphological characteristics on a larger sample size may prove helpful in differentiating benign from malignant liver masses.
Collapse
Affiliation(s)
- Soroosh Sabeti
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
| | - Redouane Ternifi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
| | - Nicholas B. Larson
- Department of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
| | - Michael C. Olson
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
| | - Thomas D. Atwell
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
| | - Azra Alizad
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, United States
- *Correspondence: Azra Alizad,
| |
Collapse
|
12
|
Kohlenberg J, Gu J, Parvinian A, Webb J, Kawkgi OE, Larson NB, Ryder M, Fatemi M, Alizad A. Added value of mass characteristic frequency to 2-D shear wave elastography for differentiation of benign and malignant thyroid nodules. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1663-1671. [PMID: 35672198 PMCID: PMC9246930 DOI: 10.1016/j.ultrasmedbio.2022.04.218] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 04/17/2022] [Accepted: 04/29/2022] [Indexed: 06/15/2023]
Abstract
Mass characteristic frequency (fmass) is a novel shear wave (SW) parameter that represents the ratio of the averaged minimum SW speed within the regions of interest to the largest dimension of the mass. Our study objective was to evaluate if the addition of fmass to conventional 2-D shear wave elastography (SWE) parameters would improve the differentiation of benign from malignant thyroid nodules. Our cohort comprised 107 patients with 113 thyroid nodules, of which 67 (59%) were malignant. Two-dimensional SWE data were obtained using the Supersonic Imagine Aixplorer ultrasound system equipped with a 44- to 15-MHz15-MHz linear array transducer. A receiver operating characteristic curve was generated based on a multivariable logistic regression analysis to evaluate the ability of SWE parameters with/without fmass and with/without clinical factors to discriminate benign from malignant thyroid nodules. The addition of fmass to conventional SW elasticity parameters increased the area under the curve from 0.808 to 0.871 (p = 0.02). The combination of SW elasticity parameters plus fmass plus clinical factors provided the strongest thyroid nodule malignancy probability estimate, with a sensitivity of 93.4% and specificity of 91.1% at the optimal threshold. In summary, fmass can be a valuable addition to conventional 2-D SWE parameters.
Collapse
Affiliation(s)
- Jacob Kohlenberg
- Division of Endocrinology, Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, USA; Division of Diabetes, Department of Medicine, Endocrinology and Metabolism, University of Minnesota, Minneapolis, MN, USA
| | - Juanjuan Gu
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Ahmad Parvinian
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 First Street SW, Rochester, MN 55905, USA
| | - Jeremy Webb
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 First Street SW, Rochester, MN 55905, USA
| | - Omar El Kawkgi
- Division of Endocrinology, Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Nicholas B Larson
- Department of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Mabel Ryder
- Division of Endocrinology, Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Azra Alizad
- Department of Radiology, Mayo Clinic College of Medicine and Science, 200 First Street SW, Rochester, MN 55905, USA.
| |
Collapse
|
13
|
Sun Y, Wang W, Mi C, Zhang Q, Zhang K. Differential Diagnosis Value of Shear-Wave Elastography for Superficial Enlarged Lymph Nodes. Front Oncol 2022; 12:908085. [PMID: 35847906 PMCID: PMC9280688 DOI: 10.3389/fonc.2022.908085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 05/31/2022] [Indexed: 11/30/2022] Open
Abstract
Objectives To evaluate the diagnostic efficiency and diagnostic threshold of conventional US and shear-wave elastography (SWE) in superficial enlarged lymph nodes (LNs). Methods A total of 204 patients with superficial enlarged LNs were enrolled in this retrospective study aged 46.0 ± 15.2 years from March 2020 to March 2021. LNs with a long axis larger than 0.7 cm were considered as superficial enlarged. Before the histological biopsy, LNs that were considered suspicious according to both conventional US and SWE were included, while LNs with no or unclear pathological results, or with no satisfactory SWE images, were excluded. The conventional and 2-D SWE examinations were performed with Aplio i800 and Acuson sequoia equipped with i18LX5 linear-array transducer (5-18 MHz) and 10L4 linear-array transducer (4-10 MHz), respectively. Both E Median and Vs Median parameters were investigated by two senior ultrasound physicians. The pathological results were performed as the gold standard. Results Variables including transverse axis size, lymphatic hilum, L/T ratio, echogenicity, and color Doppler pattern were considered significant. The mean E Median value in benign, metastatic LNs, and lymphoma were 28.26 ± 8.87 kPa, 77.46 ± 22.85 kPa, and 50.37 ± 5.41 kPa (p <0.001), while Vs Median values were 3.02 ± 0.50 m/s, 4.87 ± 0.90 m/s, and 4.09 ± 0.22 m/s, respectively (p < 0.001). The diagnostic performance indicated the high sensitivity, specificity, PPV, NPV, and overall accuracy of conventional US combined with SWE. The optimal cutoff values of E Median and Vs Median for predicting malignant LNs were 42.90 kPa and 3.73 m/s, respectively. As AUC value, sensitivity, specificity, accuracy, PPV, and NPV revealed, the indexes of E Median were 0.976, 0.927, 0.975, 0.946, 0.983, and 0.897, respectively, while Vs Median were 0.970, 0.927, 0.963, 0.941, 0.975, and 0.895, respectively (p <0.001). The ROC curves of both E Median (AUC=0.976) Vs Median (AUC=0.970) suggested the remarkable diagnostic efficiency in distinguishing benignity between suspected malignant LNs. Conclusions Above results indicated that conventional US together with 2-D SWE could elevate the diagnostic performance. Meanwhile, the parameters of 2-D SWE including E Median and Vs Median could effectively assess malignant LNs, which provide valuable differentiating information in superficial enlarged LNs.
Collapse
Affiliation(s)
- Yanjuan Sun
- Department of Ultrasound, General Hospital of Ningxia Medical University, No. 804 South Shengli Street, Yinchuan, China
| | - Wen Wang
- Department of Ultrasound, Cardiovascular and Cerebrovascular Disease Hospital, General Hospital of Ningxia Medical University, Yinchuan, China
| | - Chengrong Mi
- Department of Ultrasound, General Hospital of Ningxia Medical University, No. 804 South Shengli Street, Yinchuan, China
| | - Qian Zhang
- Department of Ultrasound, Cardiovascular and Cerebrovascular Disease Hospital, General Hospital of Ningxia Medical University, Yinchuan, China
- *Correspondence: Qian Zhang, ; Kun Zhang,
| | - Kun Zhang
- Central Laboratory and Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
- *Correspondence: Qian Zhang, ; Kun Zhang,
| |
Collapse
|
14
|
Gu J, Ternifi R, Sabeti S, Larson NB, Carter JM, Fazzio RT, Fatemi M, Alizad A. Volumetric imaging and morphometric analysis of breast tumor angiogenesis using a new contrast-free ultrasound technique: a feasibility study. Breast Cancer Res 2022; 24:85. [PMID: 36451243 PMCID: PMC9710093 DOI: 10.1186/s13058-022-01583-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 11/18/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND There is a strong correlation between the morphological features of new tumor vessels and malignancy. However, angiogenic heterogeneity necessitates 3D microvascular data of tumor microvessels for more reliable quantification. To provide more accurate information regarding vessel morphological features and improve breast lesion characterization, we introduced a quantitative 3D high-definition microvasculature imaging (q3D-HDMI) as a new easily applicable and robust tool to morphologically characterize microvasculature networks in breast tumors using a contrast-free ultrasound-based imaging approach. METHODS In this prospective study, from January 2020 through December 2021, a newly developed q3D-HDMI technique was evaluated on participants with ultrasound-identified suspicious breast lesions recommended for core needle biopsy. The morphological features of breast tumor microvessels were extracted from the q3D-HDMI. Leave-one-out cross-validation (LOOCV) was applied to test the combined diagnostic performance of multiple morphological parameters of breast tumor microvessels. Receiver operating characteristic (ROC) curves were used to evaluate the prediction performance of the generated pooled model. RESULTS Ninety-three participants (mean age 52 ± 17 years, 91 women) with 93 breast lesions were studied. The area under the ROC curve (AUC) generated with q3D-HDMI was 95.8% (95% CI 0.901-1.000), yielding a sensitivity of 91.7% and a specificity of 98.2%, that was significantly higher than the AUC generated with the q2D-HDMI (p = 0.02). When compared to q2D-HDMI, the tumor microvessel morphological parameters obtained from q3D-HDMI provides distinctive information that increases accuracy in differentiating breast tumors. CONCLUSIONS The proposed quantitative volumetric imaging technique augments conventional breast ultrasound evaluation by increasing specificity in differentiating malignant from benign breast masses.
Collapse
Affiliation(s)
- Juanjuan Gu
- grid.66875.3a0000 0004 0459 167XDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN USA
| | - Redouane Ternifi
- grid.66875.3a0000 0004 0459 167XDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN USA
| | - Soroosh Sabeti
- grid.66875.3a0000 0004 0459 167XDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN USA
| | - Nicholas B. Larson
- grid.66875.3a0000 0004 0459 167XDepartment of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, Rochester, MN USA
| | - Jodi M. Carter
- grid.66875.3a0000 0004 0459 167XDepartment of Laboratory Medicine and Pathology, Mayo Clinic College of Medicine and Science, Rochester, MN USA
| | - Robert T. Fazzio
- grid.66875.3a0000 0004 0459 167XDepartment of Radiology, Mayo Clinic College of Medicine and Science, 200 1St Street SW, Rochester, MN 55905 USA
| | - Mostafa Fatemi
- grid.66875.3a0000 0004 0459 167XDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN USA
| | - Azra Alizad
- grid.66875.3a0000 0004 0459 167XDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN USA ,grid.66875.3a0000 0004 0459 167XDepartment of Radiology, Mayo Clinic College of Medicine and Science, 200 1St Street SW, Rochester, MN 55905 USA
| |
Collapse
|