1
|
van Hal VHJ, de Hoop H, van Sambeek MRHM, Schwab HM, Lopata RGP. In vivo bistatic dual-aperture ultrasound imaging and elastography of the abdominal aorta. Front Physiol 2024; 15:1320456. [PMID: 38606009 PMCID: PMC11007781 DOI: 10.3389/fphys.2024.1320456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 02/12/2024] [Indexed: 04/13/2024] Open
Abstract
Introduction: In this paper we introduce in vivo multi-aperture ultrasound imaging and elastography of the abdominal aorta. Monitoring of the geometry and growth of abdominal aortic aneurysms (AAA) is paramount for risk stratification and intervention planning. However, such an assessment is limited by the lateral lumen-wall contrast and resolution of conventional ultrasound. Here, an in vivo dual-aperture bistatic imaging approach is shown to improve abdominal ultrasound and strain imaging quality significantly. By scanning the aorta from different directions, a larger part of the vessel circumference can be visualized. Methods: In this first-in-man volunteer study, the performance of multi-aperture ultrasound imaging and elastography of the abdominal aortic wall was assessed in 20 healthy volunteers. Dual-probe acquisition was performed in which two curved array transducers were aligned in the same imaging plane. The transducers alternately transmit and both probes receive simultaneously on each transmit event, which allows for the reconstruction of four ultrasound signals. Automatic probe localization was achieved by optimizing the coherence of the trans-probe data, using a gradient descent algorithm. Speckle-tracking was performed on the four individual bistatic signals, after which the respective axial displacements were compounded and strains were calculated. Results: Using bistatic multi-aperture ultrasound imaging, the image quality of the ultrasound images, i.e., the angular coverage of the wall, was improved which enables accurate estimation of local motion dynamics and strain in the abdominal aortic wall. The motion tracking error was reduced from 1.3 mm ± 0.63 mm to 0.16 mm ± 0.076 mm, which increased the circumferential elastographic signal-to-noise ratio (SNRe) by 12.3 dB ± 8.3 dB on average, revealing more accurate and homogeneous strain estimates compared to single-perspective ultrasound. Conclusion: Multi-aperture ultrasound imaging and elastography is feasible in vivo and can provide the clinician with vital information about the anatomical and mechanical state of AAAs in the future.
Collapse
Affiliation(s)
- Vera H. J. van Hal
- Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Hein de Hoop
- Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Marc R. H. M. van Sambeek
- Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, Netherlands
| | - Hans-Martin Schwab
- Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Richard G. P. Lopata
- Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| |
Collapse
|
2
|
Wang DS, Shen J, Majdalany BS, Khaja MS, Bhatti S, Ferencik M, Ganguli S, Gunn AJ, Heitner JF, Johri AM, Obara P, Ohle R, Sadeghi MM, Schermerhorn M, Siracuse JJ, Steenburg SD, Sutphin PD, Vijay K, Waite K, Steigner ML. ACR Appropriateness Criteria® Pulsatile Abdominal Mass, Suspected Abdominal Aortic Aneurysm: 2023 Update. J Am Coll Radiol 2023; 20:S513-S520. [PMID: 38040468 DOI: 10.1016/j.jacr.2023.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 08/22/2023] [Indexed: 12/03/2023]
Abstract
Abdominal aortic aneurysm (AAA) is defined as abnormal dilation of the infrarenal abdominal aortic diameter to 3.0 cm or greater. The natural history of AAA consists of progressive expansion and potential rupture. Although most AAAs are clinically silent, a pulsatile abdominal mass identified on physical examination may indicate the presence of an AAA. When an AAA is suspected, an imaging study is essential to confirm the diagnosis. This document reviews the relative appropriateness of various imaging procedures for the initial evaluation of suspected AAA. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
Collapse
Affiliation(s)
- David S Wang
- Stanford University Medical Center, Stanford, California.
| | - Jody Shen
- Research Author, Stanford University Medical Center, Stanford, California
| | - Bill S Majdalany
- Panel Chair, University of Vermont Medical Center, Burlington, Vermont
| | - Minhaj S Khaja
- Panel Vice-Chair, University of Michigan, Ann Arbor, Michigan
| | - Salman Bhatti
- University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; Society for Cardiovascular Magnetic Resonance
| | - Maros Ferencik
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon; Society of Cardiovascular Computed Tomography
| | - Suvranu Ganguli
- Boston Medical Center/Boston University School of Medicine, Boston, Massachusetts
| | - Andrew J Gunn
- University of Alabama at Birmingham, Birmingham, Alabama
| | - John F Heitner
- New York University Langone Health, New York, New York; Society for Cardiovascular Magnetic Resonance
| | - Amer M Johri
- Queen's University, Kingston, Ontario, Canada; American Society of Echocardiography
| | - Piotr Obara
- NorthShore University HealthSystem, Evanston, Illinois
| | - Robert Ohle
- Northern Ontario School of Medicine, Sudbury, Ontario, Canada; American College of Emergency Physicians
| | - Mehran M Sadeghi
- Yale School of Medicine, New Haven, Connecticut; American Society of Nuclear Cardiology
| | - Marc Schermerhorn
- Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, Massachusetts; Society for Vascular Surgery
| | - Jeffrey J Siracuse
- Boston Medical Centers, Boston University, and Chobanian and Avedisian School of Medicine, Boston, Massachusetts; Society for Vascular Surgery
| | - Scott D Steenburg
- Indiana University School of Medicine and Indiana University Health, Indianapolis, Indiana; Committee on Emergency Radiology-GSER
| | | | - Kanupriya Vijay
- University of Texas Southwestern Medical Center, Dallas, Texas
| | - Kathleen Waite
- Duke University Medical Center, Durham, North Carolina, Primary care physician
| | | |
Collapse
|
3
|
Maas EJ, Nievergeld AHM, Fonken JHC, Thirugnanasambandam M, van Sambeek MRHM, Lopata RGP. 3D-Ultrasound Based Mechanical and Geometrical Analysis of Abdominal Aortic Aneurysms and Relationship to Growth. Ann Biomed Eng 2023; 51:2554-2565. [PMID: 37410199 PMCID: PMC10598132 DOI: 10.1007/s10439-023-03301-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 06/22/2023] [Indexed: 07/07/2023]
Abstract
The heterogeneity of progression of abdominal aortic aneurysms (AAAs) is not well understood. This study investigates which geometrical and mechanical factors, determined using time-resolved 3D ultrasound (3D + t US), correlate with increased growth of the aneurysm. The AAA diameter, volume, wall curvature, distensibility, and compliance in the maximal diameter region were determined automatically from 3D + t echograms of 167 patients. Due to limitations in the field-of-view and visibility of aortic pulsation, measurements of the volume, compliance of a 60 mm long region and the distensibility were possible for 78, 67, and 122 patients, respectively. Validation of the geometrical parameters with CT showed high similarity, with a median similarity index of 0.92 and root-mean-square error (RMSE) of diameters of 3.5 mm. Investigation of Spearman correlation between parameters showed that the elasticity of the aneurysms decreases slightly with diameter (p = 0.034) and decreases significantly with mean arterial pressure (p < 0.0001). The growth of a AAA is significantly related to its diameter, volume, compliance, and surface curvature (p < 0.002). Investigation of a linear growth model showed that compliance is the best predictor for upcoming AAA growth (RMSE 1.70 mm/year). To conclude, mechanical and geometrical parameters of the maximally dilated region of AAAs can automatically and accurately be determined from 3D + t echograms. With this, a prediction can be made about the upcoming AAA growth. This is a step towards more patient-specific characterization of AAAs, leading to better predictability of the progression of the disease and, eventually, improved clinical decision making about the treatment of AAAs.
Collapse
Affiliation(s)
- Esther Jorien Maas
- PULS/e Group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
- Department of Vascular Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
| | - Arjet Helena Margaretha Nievergeld
- PULS/e Group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Vascular Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Judith Helena Cornelia Fonken
- PULS/e Group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Vascular Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Mirunalini Thirugnanasambandam
- PULS/e Group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Vascular Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Marc Rodolph Henricus Maria van Sambeek
- PULS/e Group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Vascular Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | | |
Collapse
|
4
|
Bissacco D, Mandigers TJ, Savaré L, Domanin M, D'Oria M, Ieva F, Van Herwaarden JA, Mani K, Wanhainen A, Trimarchi S. Editor's Choice - Comparison of the Reproducibility of Ultrasound Calliper Placement Methods in Abdominal Aortic Diameter Measurements: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies. Eur J Vasc Endovasc Surg 2023; 66:620-631. [PMID: 37331424 DOI: 10.1016/j.ejvs.2023.06.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 05/23/2023] [Accepted: 06/13/2023] [Indexed: 06/20/2023]
Abstract
OBJECTIVE To assess which ultrasound (US) method of maximum anteroposterior (AP) abdominal aortic diameter measurement can be considered most reproducible. DATA SOURCES MEDLINE, Scopus, and Web of Science were searched (PROSPERO ID: 276694). Eligible studies reported intra- and or interobserver agreement according to Bland-Altman analysis (mean ± standard deviation [SD]) for abdominal aortic diameter AP US evaluations with an outer to outer (OTO), inner to inner (ITI), and or leading edge to leading edge (LELE) calliper placement. REVIEW METHODS The Preferred Reporting Items for a Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies statement was followed. The QUADAS-2 tool and QUADAS-C extension were used for risk of bias assessment and the GRADE framework to rate the certainty of evidence. Pooled estimates (fixed effects meta-analysis, after a test of homogeneity of means) for each US method were compared with pairwise one sided t tests. Sensitivity analyses (for studies published in 2010 or later) and meta-regression were also performed. RESULTS 21 studies were included in the qualitative analysis. Twelve were eligible for quantitative analysis. Studies showed heterogeneity in the US model and transducer used, sex of participants, and observer professions, expertise, and training. Included studies shared a common mean for each US method (OTO: p = 1.0, ITI: p = 1.0, and LELE: p = 1.0). A pooled estimate of interobserver reproducibility for each US method was obtained, combining the mean ± SD (Bland-Altman analysis) from each study: OTO: 0.182 ± 0.440; ITI: 0.170 ± 0.554; and LELE: 0.437 ± 0.419. There were no statistically significant differences between the methods (OTO vs. ITI: p = .52, OTO vs. LELE: p = .069, ITI vs. LELE: p = .17). Considering studies published in 2010 and later, the pooled estimate for LELE was the smallest, without statistically significant differences between the methods. Despite the low risk of bias, the certainty of the evidence for both meta-analysed outcomes remained low. CONCLUSION The interobserver reproducibility for OTO and ITI was 2.5 times smaller (indicating better reproducibility) than LELE; however, without statistically significant differences between the methods and low GRADE evidence certainty. Additional data are needed to validate these findings, while inherent differences between the methods need to be emphasised.
Collapse
Affiliation(s)
- Daniele Bissacco
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Tim J Mandigers
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Vascular Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands.
| | - Laura Savaré
- Modelling and Scientific Computing (MOX), Department of Mathematics, Politecnico di Milano, Milan, Italy; Centre for Health Data Science (HDS), Human Technopole, Milan, Italy; Centre for Healthcare Research and Pharmacoepidemiology (CHRP), University of Milano-Bicocca, Milan, Italy
| | - Maurizio Domanin
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| | - Mario D'Oria
- Division of Vascular and Endovascular Surgery, Cardiovascular Department, University Hospital of Trieste, Trieste, Italy
| | - Francesca Ieva
- Modelling and Scientific Computing (MOX), Department of Mathematics, Politecnico di Milano, Milan, Italy; Centre for Health Data Science (HDS), Human Technopole, Milan, Italy; Centre for Healthcare Research and Pharmacoepidemiology (CHRP), University of Milano-Bicocca, Milan, Italy
| | - Joost A Van Herwaarden
- Department of Vascular Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Kevin Mani
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden
| | - Anders Wanhainen
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden
| | - Santi Trimarchi
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
5
|
Thanigaimani S, Iyer V, Bingley J, Browne D, Phie J, Doolan D, Golledge J. Association Between Serum MicroRNAs and Abdominal Aortic Aneurysm Diagnosis and Growth. Eur J Vasc Endovasc Surg 2023; 65:573-581. [PMID: 36596338 DOI: 10.1016/j.ejvs.2022.12.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 12/13/2022] [Accepted: 12/24/2022] [Indexed: 01/01/2023]
Abstract
OBJECTIVE This study aimed to examine the association between serum microRNAs (miRNAs) and diagnosis and growth of abdominal aortic aneurysm (AAA), and to test their diagnostic and prognostic value. METHODS The expression levels of 800 miRNA tags were assessed in 108 patients with AAA, 12 age and sex matched healthy controls (HCs), and 12 patients with peripheral artery disease (PAD) using NanoString technology. Findings were assessed in an independent sample of 66 patients with AAA and 29 age and sex matched HCs by reverse transcriptase polymerase chain reaction. AAA growth was assessed by a median of three (interquartile range [IQR] 2, 3) repeat ultrasound scans over a median follow up of 1.1 (IQR 1.0, 2.0) years. The association between the miRNA and AAA diagnosis and growth was examined by regression and linear mixed effects analyses. The diagnostic and prognostic potential of the miRNAs were examined using area under the receiver operator characteristic curve (AUC), net re-classification index (NRI), and Cox hazard analyses. RESULTS In comparison with HCs, a model combining clinical risk factors, let-7b-5p and miR-548n had an AUC of 98.0% (95% confidence interval [CI] 95.6 - 100.0; p = .003) for diagnosing AAA, which was a significant improvement over clinical risk factors alone (NRI 1.74; 95% CI 1.61 - 1.87; p < .001). Compared with PAD, a model combining clinical risk factors and miR-548n had an AUC of 99.6% (95% CI 98.9 - 100.0, p = .037) for diagnosing AAA, which was a significant improvement over clinical risk factors alone (NRI 1.79, 95% CI 1.68 - 1.91; p < .001). In the longitudinal cohort, none of the miRNAs were able to predict the likelihood of reaching surgical threshold diameter better than clinical risk factors alone. CONCLUSION Serum let-7b-5p and miR548n significantly improved the ability to diagnose AAA. None of the miRNAs had independent prognosis value in predicting AAA growth.
Collapse
Affiliation(s)
- Shivshankar Thanigaimani
- Queensland Research Centre for Peripheral Vascular Disease, College of Medicine and Dentistry, James Cook University, Townsville, Queensland, Australia; Centre for Molecular Therapeutics, Australian Institute of Tropical Health and Medicine, James Cook University, Cairns and Townsville, Queensland, Australia
| | - Vikram Iyer
- Queensland Research Centre for Peripheral Vascular Disease, College of Medicine and Dentistry, James Cook University, Townsville, Queensland, Australia; Centre for Molecular Therapeutics, Australian Institute of Tropical Health and Medicine, James Cook University, Cairns and Townsville, Queensland, Australia; Department of Vascular Surgery, Royal Melbourne Hospital, Parkville, Victoria, Australia
| | - John Bingley
- Department of Vascular Surgery, Mater Hospital, Brisbane
| | - Daniel Browne
- Centre for Molecular Therapeutics, Australian Institute of Tropical Health and Medicine, James Cook University, Cairns and Townsville, Queensland, Australia
| | - James Phie
- Queensland Research Centre for Peripheral Vascular Disease, College of Medicine and Dentistry, James Cook University, Townsville, Queensland, Australia; Centre for Molecular Therapeutics, Australian Institute of Tropical Health and Medicine, James Cook University, Cairns and Townsville, Queensland, Australia
| | - Denise Doolan
- Centre for Molecular Therapeutics, Australian Institute of Tropical Health and Medicine, James Cook University, Cairns and Townsville, Queensland, Australia
| | - Jonathan Golledge
- Queensland Research Centre for Peripheral Vascular Disease, College of Medicine and Dentistry, James Cook University, Townsville, Queensland, Australia; Centre for Molecular Therapeutics, Australian Institute of Tropical Health and Medicine, James Cook University, Cairns and Townsville, Queensland, Australia; The Department of Vascular and Endovascular Surgery, Townsville University Hospital, Townsville, Queensland, Australia.
| |
Collapse
|
6
|
Hill BG, Holloway R, Lim J, Clifford K, Lesche S, Letts J, Krysa J. The correlation between different ultrasound planes and computed tomography measures of abdominal aortic aneurysms. Australas J Ultrasound Med 2023; 26:5-12. [PMID: 36960142 PMCID: PMC10030093 DOI: 10.1002/ajum.12319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Introduction Ultrasound measurements of the aorta are typically taken in the axial plane, with the transducer perpendicular to the aorta, and diameter measurements are obtained by placing the callipers from the anterior to the posterior wall and the transverse right to the left side of the aorta. While the 'conventional' anteroposterior walls in both sagittal and transverse plains may be suitable for aneurysms with less complicated geometry, there is controversy regarding the suitability of this approach for complicated, particularly tortuous aneurysms, as they may offer a more challenging situation. Previous work undertaken within our research group found that when training inexperienced users of ultrasound, they demonstrated more optimal calliper placement to the abdominal aorta when approached from a decubitus window to obtain a coronal image compared to the traditional ultrasound approach. Purpose To observe the level of agreement in real-world reporting between computed tomography (CT) and ultrasound measurements in three standard planes; transverse AP, sagittal AP and coronal (left to right) infra-renal abdominal aortic aneurysm (AAA) diameter. Methodology This is a retrospective review of the Otago Vascular Diagnostics database for AAA, where ultrasound and CT diameter data, available within 90 days of each other, were compared. In addition to patient demographics, the infrarenal aorta ultrasound diameter measurements in transverse AP and sagittal AP, along with a coronal decubitus image of the aorta was collected. No transverse measurement was performed from the left to the right of the aorta. Results Three hundred twenty-five participants (238 males, mean age 76.4 ± 7.5) were included. Mean ultrasound outer to the outer wall, transverse AP and sagittal AP diameters were 48.7 ± 10.5 mm and 48.9 ± 9.9 mm, respectively. The coronal diameter measurement of the aorta from left to right was 53.9 ± 12.8 mm in the left decubitus window. The mean ultrasound max was 54.3 ± 12.6 mm. The mean CT diameter measurement was 55.6 ± 12.7 mm. Correlation between the CT max and ultrasound max was r 2 = 0.90, and CT with the coronal measurement r 2 = 0.90, CT and AP transverse was r2=0.80, and CT with AP sagittal measurement was r 2 = 0.77. Conclusion The decubitus ultrasound window of the abdominal aorta, with measurement of the coronal plane, is highly correlated and in agreement with CT scanning. This window may offer an alternative approach to measuring the infrarenal abdominal aortic aneurysm and should be considered when performing surveillance of all infra-renal AAA.
Collapse
Affiliation(s)
- Brigid G Hill
- Department of Surgical Sciences, Otago Medical SchoolUniversity of OtagoDunedinNew Zealand
| | - Rossi Holloway
- Department of SurgeryTe Whatu Ora Health New Zealand, SouthernDunedinNew Zealand
| | - Joyce Lim
- Department of RadiologyTe Whatu Ora Health New Zealand, SouthernDunedinNew Zealand
| | - Kari Clifford
- Department of Surgical Sciences, Otago Medical SchoolUniversity of OtagoDunedinNew Zealand
| | - Sarah Lesche
- Department of Surgical Sciences, Otago Medical SchoolUniversity of OtagoDunedinNew Zealand
- Department of SurgeryTe Whatu Ora Health New Zealand, SouthernDunedinNew Zealand
| | - James Letts
- Department of RadiologyTe Whatu Ora Health New Zealand, SouthernDunedinNew Zealand
| | - Jolanda Krysa
- Department of Surgical Sciences, Otago Medical SchoolUniversity of OtagoDunedinNew Zealand
- Department of SurgeryTe Whatu Ora Health New Zealand, SouthernDunedinNew Zealand
| |
Collapse
|
7
|
Type I Interferon Receptor Subunit 1 Deletion Attenuates Experimental Abdominal Aortic Aneurysm Formation. Biomolecules 2022; 12:biom12101541. [PMID: 36291750 PMCID: PMC9599283 DOI: 10.3390/biom12101541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/14/2022] [Accepted: 10/17/2022] [Indexed: 11/16/2022] Open
Abstract
Objective: Type I interferon receptor signaling contributes to several autoimmune and vascular diseases such as lupus, atherosclerosis and stroke. The purpose of this study was to assess the influence of type I interferon receptor deficiency on the formation and progression of experimental abdominal aortic aneurysms (AAAs). Methods: AAAs were induced in type I interferon receptor subunit 1 (IFNAR1)-deficient and wild type control male mice via intra-infrarenal aortic infusion of porcine pancreatic elastase. Immunostaining for IFNAR1 was evaluated in experimental and clinical aneurysmal abdominal aortae. The initiation and progression of experimental AAAs were assessed via ultrasound imaging prior to (day 0) and days 3, 7 and 14 following elastase infusion. Aneurysmal histopathology was analyzed at sacrifice. Results: Increased aortic medial and adventitial IFNAR1 expression was present in both clinical AAAs harvested at surgery and experimental AAAs. Following AAA induction, wild type mice experienced progressive, time-dependent infrarenal aortic enlargement. This progression was substantially attenuated in IFNAR1-deficient mice. On histological analyses, medial elastin degradation, smooth muscle cell depletion, leukocyte accumulation and neoangiogenesis were markedly diminished in IFNAR1-deficient mice in comparison to wild type mice. Conclusion: IFNAR1 deficiency limited experimental AAA progression in response to intra-aortic elastase infusion. Combined with clinical observations, these results suggest an important role for IFNAR1 activity in AAA pathogenesis.
Collapse
|
8
|
Golledge J, Velu R, Quigley F, Jenkins J, Singh TP. Editor's Choice - Cohort Study Examining the Association Between Abdominal Aortic Size and Major Adverse Cardiovascular Events in Patients with Aortic and Peripheral Occlusive and Aneurysmal Disease. Eur J Vasc Endovasc Surg 2021; 62:960-968. [PMID: 34740532 DOI: 10.1016/j.ejvs.2021.09.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 07/12/2021] [Accepted: 09/12/2021] [Indexed: 01/15/2023]
Abstract
OBJECTIVE The aim of this study was to examine whether there were independent associations between abdominal aortic diameter, size index, and height index and the risk of major adverse events in patients referred for treatment of various types of aortic and peripheral occlusive and aneurysmal disease (APOAD). METHODS In total, 1 752 participants with a variety of APOADs were prospectively recruited between 2002 and 2020 and had a maximum abdominal aortic diameter, aortic size index (aortic diameter relative to body surface area), and aortic height index (aortic diameter relative to height) measured by ultrasound at recruitment. Participants were followed for a median of 4.6 years (interquartile range 2.0 - 8.0 years) to record outcome events, including major adverse cardiovascular events (MACE), peripheral artery surgery, abdominal aortic aneurysm (AAA) events (rupture or repair), and all cause mortality. The association between aortic size and events was assessed using Cox proportional hazard analysis. The ability of aortic size to improve risk of events classification was assessed using the net reclassification index (NRI). RESULTS After adjusting for other risk factors, larger aortic diameter was associated with an increased risk of MACE (hazard ratio [HR] 1.17, 95% confidence interval [CI] 1.05 - 1.31), requirement for peripheral artery surgery (HR 2.05, 95% CI 1.90 - 2.22), AAA events (HR 3.01, 95% CI 2.77 - 3.26), and all cause mortality (HR 1.20, 95% CI 1.08 - 1.32). Findings were similar for aortic size and aortic height indices. According to the NRI, all three aortic size measures significantly improved classification of risk of peripheral artery surgery and AAA events but not MACE. Aortic size index, but not aortic diameter or aortic height index, significantly improved the classification of all cause mortality risk. CONCLUSION Larger abdominal aortic diameter, size index, and height index are all independently associated with an increased risk of major adverse events in patients with established vascular disease.
Collapse
Affiliation(s)
- Jonathan Golledge
- Queensland Research Centre for Peripheral Vascular Disease, College of Medicine and Dentistry, James Cook University, Townsville, Queensland, Australia; The Department of Vascular and Endovascular Surgery, The Townsville University Hospital, Townsville, Queensland, Australia; The Australian Institute of Tropical Health and Medicine, James Cook University, Townsville, Queensland, Australia.
| | - Ramesh Velu
- The Department of Vascular and Endovascular Surgery, The Townsville University Hospital, Townsville, Queensland, Australia
| | - Frank Quigley
- The Mater Hospital, Townsville, Queensland, Australia
| | - Jason Jenkins
- Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
| | - Tejas P Singh
- Queensland Research Centre for Peripheral Vascular Disease, College of Medicine and Dentistry, James Cook University, Townsville, Queensland, Australia; The Department of Vascular and Endovascular Surgery, The Townsville University Hospital, Townsville, Queensland, Australia
| |
Collapse
|