1
|
Savaş H, Guler S. Prevention of catheter-related bloodstream infections in patients with extracorporeal membrane oxygenation: a literature review. REVISTA DA ASSOCIACAO MEDICA BRASILEIRA (1992) 2023; 69:e20230491. [PMID: 37729228 PMCID: PMC10511280 DOI: 10.1590/1806-9282.20230491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 07/22/2023] [Indexed: 09/22/2023]
Affiliation(s)
- Hafize Savaş
- Lokman Hekim University, Faculty of Health Sciences, Nursing Department – Ankara, Turkey
| | - Sevil Guler
- Gazi University, Faculty of Nursing – Ankara, Turkey
| |
Collapse
|
2
|
Lucchini A, Elli S, Piovera D, Grossulè M, Giannini L, Cannizzo L, Crosignani A, Rona R, Foti G, Giani M. Management of vascular access for extracorporeal life support: A cohort study. J Vasc Access 2023; 24:1167-1173. [PMID: 34763544 DOI: 10.1177/11297298211056755] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Extracorporeal membrane oxygenation (ECMO) is required for patients with refractory cardiac or respiratory failure. Inadequate securement of ECMO cannulae may lead to adverse events, ranging from line kinking to catastrophic accidents, such as air entrainment into the circuit or massive bleeding. Furthermore, the micro-motion of the cannulae at the entry site might increase the risk of local infections. Since 2015, we implemented a written protocol for management of ECMO cannulae and tubing, which specifically includes the securement of each cannula with three sutureless devices. The aim of the present study was to retrospectively assess cannulae micro-motion and the rate of bleeding events at the insertion site. Secondarily we aimed to evaluate the impact of prone positioning maneuvers during ECMO on these events. We performed a single-centre retrospective analysis of prospectively collected data on nursing care of ECMO cannulae. We included adult patients treated with veno-venous (V-V) or veno-arterial (V-A) ECMO between 2015 and 2018 in our general intensive care unit. The distance between the insertion site and the end of the wire-wound part of the cannula was recorded daily. Variations of this distance (defined as "cannula micro-motion") were recorded. Forty-five ECMO consecutive adult patients (40 V-V and 5 V-A) were included. No accidental cannula dislodgement was recorded. Median daily "cannula micro-motion" was 0.0 (-0.5 to 0.2) cm, without any significant difference between ECMO configuration, cannula type, and insertion site. Twelve patients (26%) presented at least one bleeding episode at cannula insertion site, none of which required surgical intervention. In the subgroup of patients who underwent prone positioning, no difference in cannulae micro-motion was recorded. An ECMO nursing protocol for cannulae management providing sutureless devices for cannula and tubing securement allows safe line stabilization, with the potential to reduce complications related to ECMO vascular access.
Collapse
Affiliation(s)
- Alberto Lucchini
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| | - Stefano Elli
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| | - Daniele Piovera
- General Intensive Care and ECMO Unit, IRCCS San Matteo, Pavia, Italy
| | | | - Luciano Giannini
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| | - Luigi Cannizzo
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| | - Andrea Crosignani
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| | - Roberto Rona
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| | - Guseppe Foti
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| | - Marco Giani
- General Intensive Care Unit, Emergency Department, ASST Monza San Gerardo Hospital, Monza, Italy
- University of Milano-Bicocca, Milan, Italy
| |
Collapse
|
3
|
Winiszewski H, Boyadjian C, Piton G. Extracorporeal Membrane Oxygenation Cannula-Related Infections: Possible Interaction Between Prevention and Diagnosis. ASAIO J 2022; 68:e36. [PMID: 34669622 DOI: 10.1097/mat.0000000000001600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Affiliation(s)
- Hadrien Winiszewski
- Medical Intensive Care Unit, University Hospital, Besancon, France
- Research Unit EA 3920 and SFR FED 4234, University of Franche Comté, Besancon, France
| | | | - Gaël Piton
- Medical Intensive Care Unit, University Hospital, Besancon, France
- Research Unit EA 3920 and SFR FED 4234, University of Franche Comté, Besancon, France
| |
Collapse
|