1
|
Lindemann ME, Jentzen W, Kersting D, Fragoso Costa P, Küper A, Umutlu L, Herrmann K, Quick HH. Detection and quantification of small and low-uptake lesions for differentiated thyroid carcinoma using non-time-of-flight iodine-124 PET/MRI. Med Phys 2025; 52:837-846. [PMID: 39589271 PMCID: PMC11788235 DOI: 10.1002/mp.17535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2024] [Revised: 10/31/2024] [Accepted: 11/11/2024] [Indexed: 11/27/2024] Open
Abstract
BACKGROUND 124-iodine (124I) is used for positron emission tomography (PET) diagnostics and therapy planning in patients with differentiated thyroid cancer (DTC). Small lesion sizes (<10 mm) and low 124I uptake are challenging conditions for the detection of DTC lymph node lesions. PURPOSE The aim of this study was to systematically investigate the lesion detectability and quantification performance under clinically challenging imaging conditions using non-time-of-flight (TOF) PET/magnetic resonance imaging (MRI) in the clinical context of radionuclide therapy planning of DTC patients. METHODS PET/MR measurements were performed on the Siemens Biograph mMR using a small lesion NEMA-like phantom (six glass spheres, diameters 3.7-9.7 mm). 60 min list-mode data were acquired for nine activity concentrations (AC) ranging from 25 kBq/mL to 0.25 kBq/mL using a sphere-to-background ratio of 20:1. PET list-mode data were divided into five timeframes (60, 30, 16, 8, and 4 min) and reconstructed using either ordered-subsets expectation maximization (OSEM) or OSEM+ point spread function (PSF) algorithm. For all reconstructions, the smallest detectable sphere size was investigated in a human observer study. Partial volume effect (PVE) corrected PET images (contour and oversize-based approach) were analyzed considering a ± 30% deviation range between imaged and true AC as acceptable. Clinical data of eight DTC patients with small lymph node lesions were evaluated to assess agreement between the PVE correction approaches. RESULTS Longer PET acquisition times, higher ACs, and PSF reconstructions resulted in improved PET image quality and overall improved lesion detectability. The smallest 3.7 mm sphere was only visible under the best imaging conditions. Using a typical clinical 124I whole-body PET/MRI protocol with an acquisition time of 8 min using OSEM reconstructions, all lesions of ≥ 6.5 mm in diameter could be detected and the quantification provided reliable results approximately above 5.0 kBq/mL. An accurate quantification of ACs in the 4.8 mm sphere was not feasible in this study. In the clinical evaluation of 10 lesions, a good agreement between oversize- and contour-based PVE corrections was observed (<15% deviation). CONCLUSIONS The results showed that a reliable quantification of 124I uptake with PET/MRI is feasible and, therefore, could be used to perform radioiodine pre-therapy lesion dosimetry and individualized therapy planning in DTC patients.
Collapse
Affiliation(s)
- Maike E. Lindemann
- High‐Field and Hybrid MR ImagingUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
| | - Walter Jentzen
- Department of Nuclear MedicineUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
- German Cancer Consortium (DKTK, Partner Site Essen)EssenGermany
| | - David Kersting
- Department of Nuclear MedicineUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
- German Cancer Consortium (DKTK, Partner Site Essen)EssenGermany
| | - Pedro Fragoso Costa
- Department of Nuclear MedicineUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
- German Cancer Consortium (DKTK, Partner Site Essen)EssenGermany
| | - Alina Küper
- Department of Nuclear MedicineUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
- German Cancer Consortium (DKTK, Partner Site Essen)EssenGermany
| | - Lale Umutlu
- Department of Diagnostic and Interventional Radiology and NeuroradiologyUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
| | - Ken Herrmann
- Department of Nuclear MedicineUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
- German Cancer Consortium (DKTK, Partner Site Essen)EssenGermany
| | - Harald H. Quick
- High‐Field and Hybrid MR ImagingUniversity Hospital EssenUniversity of Duisburg‐EssenEssenGermany
- Erwin L. Hahn Institute for Magnetic Resonance ImagingUniversity of Duisburg‐EssenEssenGermany
| |
Collapse
|
2
|
Akamatsu G, Tsutsui Y, Daisaki H, Mitsumoto K, Baba S, Sasaki M. A review of harmonization strategies for quantitative PET. Ann Nucl Med 2023; 37:71-88. [PMID: 36607466 PMCID: PMC9902332 DOI: 10.1007/s12149-022-01820-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 12/27/2022] [Indexed: 01/07/2023]
Abstract
PET can reveal in vivo biological processes at the molecular level. PET-derived quantitative values have been used as a surrogate marker for clinical decision-making in numerous clinical studies and trials. However, quantitative values in PET are variable depending on technical, biological, and physical factors. The variability may have a significant impact on a study outcome. Appropriate scanner calibration and quality control, standardization of imaging protocols, and any necessary harmonization strategies are essential to make use of PET as a biomarker with low bias and variability. This review summarizes benefits, limitations, and remaining challenges for harmonization of quantitative PET, including whole-body PET in oncology, brain PET in neurology, PET/MR, and non-18F PET imaging. This review is expected to facilitate harmonization of quantitative PET and to promote the contribution of PET-derived biomarkers to research and development in medicine.
Collapse
Affiliation(s)
- Go Akamatsu
- Department of Advanced Nuclear Medicine Sciences, Institute for Quantum Medical Sciences, National Institutes for Quantum Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, Japan. .,Department of Molecular Imaging Research, Kobe City Medical Center General Hospital, 2-1-1 Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo, 650-0047, Japan.
| | - Yuji Tsutsui
- Department of Radiological Science, Faculty of Health Science, Junshin Gakuen University, 1-1-1 Chikushigaoka, Minami-ku, Fukuoka, 815-8510 Japan
| | - Hiromitsu Daisaki
- Department of Radiological Technology, Gunma Prefectural College of Health Sciences, 323-1 Kamioki-machi, Maebashi, Gunma 371-0052 Japan
| | - Katsuhiko Mitsumoto
- Department of Clinical Radiology Service, Kyoto University Hospital, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507 Japan
| | - Shingo Baba
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582 Japan
| | - Masayuki Sasaki
- Department of Medical Quantum Science, Faculty of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582 Japan
| |
Collapse
|
3
|
Grafe H, Lindemann ME, Weber M, Kirchner J, Binse I, Umutlu L, Herrmann K, Quick HH. Intra-Individual Comparison of 124I-PET/CT and 124I-PET/MR Hybrid Imaging of Patients with Resected Differentiated Thyroid Carcinoma: Aspects of Attenuation Correction. Cancers (Basel) 2022; 14:cancers14133040. [PMID: 35804811 PMCID: PMC9264885 DOI: 10.3390/cancers14133040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/03/2022] [Accepted: 06/15/2022] [Indexed: 02/04/2023] Open
Abstract
Simple Summary This study evaluates the qualitative and quantitative differences between 124-iodine PET/CT and PET/MR in oncologic patients with differentiated thyroid carcinoma after thyroidectomy. The impact of improved MR-based attenuation correction (AC) using a bone atlas was analysed in PET/MR data. Despite different patient positioning and AC methods PET/CT and PET/MR provide overall comparable results in a clinical setting. The overall number of detected 124I-active lesions and the measured average SUVmean values for congruent lesions were higher for PET/MR when compared to PET/CT. The addition of bone to the MR-based AC in PET/MR slightly increased the SUVmean values for all detected lesions. Abstract Background: This study evaluates the quantitative differences between 124-iodine (I) positron emission tomography/computed tomography (PET/CT) and PET/magnetic resonance imaging (PET/MR) in patients with resected differentiated thyroid carcinoma (DTC). Methods: N = 43 124I PET/CT and PET/MR exams were included. CT-based attenuation correction (AC) in PET/CT and MR-based AC in PET/MR with bone atlas were compared concerning bone AC in the head-neck region. AC-map artifacts (e.g., dentures) were noted. Standardized uptake values (SUV) were measured in lesions in each PET data reconstruction. Relative differences in SUVmean were calculated between PET/CT and PET/MR with bone atlas. Results: Overall, n = 111 124I-avid lesions were detected in all PET/CT, while n = 132 lesions were detected in PET/MR. The median in SUVmean for n = 98 congruent lesions measured in PET/CT was 12.3. In PET/MR, the median in SUVmean was 16.6 with bone in MR-based AC. Conclusions: 124I-PET/CT and 124I-PET/MR hybrid imaging of patients with DTC after thyroidectomy provides overall comparable quantitative results in a clinical setting despite different patient positioning and AC methods. The overall number of detected 124I-avid lesions was higher for PET/MR compared to PET/CT. The measured average SUVmean values for congruent lesions were higher for PET/MR.
Collapse
Affiliation(s)
- Hong Grafe
- Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany; (M.W.); (I.B.); (K.H.)
- Correspondence: ; Tel.: +49-201-723-2033
| | - Maike E. Lindemann
- High-Field and Hybrid MR Imaging, University Hospital Essen, University Duisburg-Essen, 45147 Essen, Germany; (M.E.L.); (H.H.Q.)
| | - Manuel Weber
- Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany; (M.W.); (I.B.); (K.H.)
| | - Julian Kirchner
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Hospital Dusseldorf, 40225 Dusseldorf, Germany;
| | - Ina Binse
- Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany; (M.W.); (I.B.); (K.H.)
| | - Lale Umutlu
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, 45147 Essen, Germany;
| | - Ken Herrmann
- Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany; (M.W.); (I.B.); (K.H.)
| | - Harald H. Quick
- High-Field and Hybrid MR Imaging, University Hospital Essen, University Duisburg-Essen, 45147 Essen, Germany; (M.E.L.); (H.H.Q.)
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, 45141 Essen, Germany
| |
Collapse
|
4
|
Prognostic Value of Hybrid PET/MR Imaging in Patients with Differentiated Thyroid Cancer. Cancers (Basel) 2022; 14:cancers14122958. [PMID: 35740623 PMCID: PMC9220891 DOI: 10.3390/cancers14122958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 06/13/2022] [Accepted: 06/15/2022] [Indexed: 02/01/2023] Open
Abstract
Background: Hybrid positron emission tomography (PET)/magnetic resonance (MR) is an emerging imaging modality with great potential to provide complementary data acquired at the same time, under the same physiological conditions. The aim of this study was to evaluate the prognostic value of hybrid 18F-fluorodeoxyglucose (FDG) PET/MR in patients with differentiated thyroid cancer (DTC) who underwent total thyroidectomy and radioactive iodine therapy for suspicion of disease relapse. Methods: Between November 2015 and February 2017, 55 patients underwent hybrid 18F-FDG PET/MR. Assessment of positive MR was made considering all sequences in terms of malignancy based on the morphological T2-weighted features and the presence of restricted diffusivity on diffusion-weighted imaging images and both needed to be positive on the same lesion. Both foci with abnormal 18F-FDG uptake, which corresponded to tissue abnormalities on the MR, and tracer accumulation, which did not correspond to normal morphological structures, were considered positive. Results: During follow-up (mean 42 ± 27 months), 29 patients (53%) had disease recurrence. In the Cox univariate regression analysis age, serum Tg level ≥ 2 ng/mL, positive short tau inversion recovery (STIR), and positive PET were significant predictors of DTC recurrence. Kaplan−Meier survival analyses showed that patients with Tg ≥ 2 ng/mL had poorer outcomes compared to those with serum Tg level < 2 ng/mL (p < 0.05). Similarly, patients with positive STIR and positive PET had a worst outcome compared to those with negative STIR (p < 0.05) and negative PET (p < 0.005). Survival analysis performed in the subgroup of 36 subjects with Tg level ≥ 2 ng/mL revealed that patients with positive PET had a worst outcome compared to those with negative PET (p < 0.05). Conclusions: Age, serum Tg level ≥ 2 ng/mL, positive STIR, and positive 18F-FDG PET were significant predictors of DTC recurrence. However, the serum Tg level was the only independent predictor of DTC. Hybrid PET/MR imaging may have the potential to improve the information content of one modality with the other and would offer new opportunities in patients with DTC. Thus, further studies in a larger patient population are needed to understand the additional value of 18F-FDG PET/MR in patients with DTC.
Collapse
|
5
|
Bzowski P, Borys D, Gorczewski K, Chmura A, Daszewska K, Gorczewska I, Kastelik-Hryniewiecka A, Szydło M, d’Amico A, Sokół M. Efficiency of 124I radioisotope production from natural and enriched tellurium dioxide using 124Te(p,xn) 124I reaction. EJNMMI Phys 2022; 9:41. [PMID: 35666325 PMCID: PMC9170869 DOI: 10.1186/s40658-022-00471-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 05/19/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND 124I Iodine (T[Formula: see text] = 4.18 d) is the only long-life positron emitter radioisotope of iodine that may be used for both imaging and therapy as well as for 131I dosimetry. Its physical characteristics permits taking advantages of the higher Positron Emission Tomography (PET) image quality, whereas the availability of new molecules to be targeted with 124I makes it a novel innovative radiotracer probe for a specific molecular targeting. RESULTS In this study Monte Carlo and SRIM/TRIM modelling was applied to predict the nuclear parameters of the 124I production process in a small medical cyclotron IBA 18/9 Cyclone. The simulation production yields for 124I and the polluting radioisotopes were calculated for the natural and enriched 124TeO2 + Al2O3 solid targets irradiated with 14.8 MeV protons. The proton beam was degraded energetically from 18 MeV with 0.2 mm Havar foil. The 124Te(p,xn)124I reactions were taken into account in the simulations. The optimal thickness of the target material was calculated using the SRIM/TRIM and Geant4 codes. The results of the simulations were compared with the experimental data obtained for the natural TeO2 +Al2O3 target. The dry distillation technique of the 124-iodine was applied. CONCLUSIONS The experimental efficiency for the natural Te target was better than 41% with an average thick target (>0.8 mm) yield of 1.32 MBq/μAh. Joining the Monte Carlo and experimental approaches makes it possible to optimize the methodology for the 124I production from the expensive Te enriched targets.
Collapse
Affiliation(s)
- Paweł Bzowski
- Department of Nuclear Medicine and Endocrine Oncology, PET Diagnostics Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
- Department of Systems Biology and Engineering, Silesian University of Technology, Akademicka 16, 44-100 Gliwice, Poland
- Biotechnology Center, Silesian University of Technology, Krzywoustego 8, 44-100 Gliwice, Poland
| | - Damian Borys
- Department of Nuclear Medicine and Endocrine Oncology, PET Diagnostics Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
- Department of Systems Biology and Engineering, Silesian University of Technology, Akademicka 16, 44-100 Gliwice, Poland
- Biotechnology Center, Silesian University of Technology, Krzywoustego 8, 44-100 Gliwice, Poland
| | - Kamil Gorczewski
- Department of Nuclear Medicine and Endocrine Oncology, PET Diagnostics Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Agnieszka Chmura
- Radiopharmacy and Preclinical PET Imaging Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Kinga Daszewska
- Radiopharmacy and Preclinical PET Imaging Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Izabela Gorczewska
- Department of Nuclear Medicine and Endocrine Oncology, PET Diagnostics Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Anna Kastelik-Hryniewiecka
- Radiopharmacy and Preclinical PET Imaging Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Marcin Szydło
- Radiopharmacy and Preclinical PET Imaging Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Andrea d’Amico
- Department of Nuclear Medicine and Endocrine Oncology, PET Diagnostics Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| | - Maria Sokół
- Department of Medical Physics, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
| |
Collapse
|
6
|
Kersting D, Jentzen W, Sraieb M, Costa PF, Conti M, Umutlu L, Antoch G, Nader M, Herrmann K, Fendler WP, Rischpler C, Weber M. Comparing lesion detection efficacy and image quality across different PET system generations to optimize the iodine-124 PET protocol for recurrent thyroid cancer. EJNMMI Phys 2021; 8:14. [PMID: 33587222 PMCID: PMC7884562 DOI: 10.1186/s40658-021-00361-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 01/28/2021] [Indexed: 12/13/2022] Open
Abstract
Background In recurrent differentiated thyroid cancer patients, detectability in 124I PET is limited for lesions with low radioiodine uptake. We assess the improvements in lesion detectability and image quality between three generations of PET scanners with different detector technologies. The results are used to suggest an optimized protocol. Methods Datasets of 10 patients with low increasing thyroglobulin or thyroglobulin antibody levels after total thyroidectomy and radioiodine therapies were included. PET data were acquired and reconstructed on a Biograph mCT PET/CT (whole-body, 4-min acquisition time per bed position; OSEM, OSEM-TOF, OSEM-TOF+PSF), a non-TOF Biograph mMR PET/MR (neck region, 4 min and 20 min; OSEM), and a new generation Biograph Vision PET/CT (whole-body, 4 min; OSEM, OSEM-TOF, OSEM-TOF+PSF). The 20-min image on the mMR was used as reference to calculate the detection efficacy in the neck region. Image quality was rated on a 5-point scale. Results All detected lesions were in the neck region. Detection efficacy was 8/9 (Vision OSEM-TOF and OSEM-TOF+PSF), 4/9 (Vision OSEM), 3/9 (mMR OSEM and mCT OSEM-TOF+PSF), and 2/9 (mCT OSEM and OSEM-TOF). Median image quality was 4 (Vision OSEM-TOF and OSEM-TOF+PSF), 3 (Vision OSEM, mCT OSEM-TOF+PSF, and mMR OSEM 20-min), 2 (mCT OSEM-TOF), 1.5 (mCT OSEM), and 1 (mMR OSEM 4 min). Conclusion At a clinical standard acquisition time of 4 min per bed position, the new generation Biograph Vision using a TOF-based image reconstruction demonstrated the highest detectability and image quality and should, if available, be preferably used for imaging of low-uptake lesions. A prolonged acquisition time for the mostly affected neck region can be useful. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00361-y.
Collapse
Affiliation(s)
- David Kersting
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany. .,West German Cancer Center (WTZ), Essen, Germany. .,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany.
| | - Walter Jentzen
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| | - Miriam Sraieb
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| | - Pedro Fragoso Costa
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| | | | - Lale Umutlu
- West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany.,Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
| | - Gerald Antoch
- German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany.,Medical Faculty, Department of Diagnostic and Interventional Radiology, University Dusseldorf, 40225, Dusseldorf, Germany
| | - Michael Nader
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| | - Ken Herrmann
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| | - Wolfgang Peter Fendler
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| | - Christoph Rischpler
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| | - Manuel Weber
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Essen and Dusseldorf, Germany
| |
Collapse
|
7
|
Bonjoc KJ, Young H, Warner S, Gernon T, Maghami E, Chaudhry A. Thyroid cancer diagnosis in the era of precision imaging. J Thorac Dis 2020; 12:5128-5139. [PMID: 33145090 PMCID: PMC7578495 DOI: 10.21037/jtd.2019.08.37] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Thyroid cancer affects 1.3% of the population with increasing rates of incidence over the last decade (approximately 2% per year). Although the overall prognosis is good in the differentiated subtypes, there has been a slow but steady increase in rate of deaths associated with thyroid cancer (approximately 0.7% per year over the last decade). Thyroid cancer is usually detected when: (I) patients feel a lump in the neck; (II) a routine clinical exam is performed; (III) an incidental thyroid nodule is identified on diagnostic imaging (e.g., CT neck or chest, carotid ultrasound, PET scan acquired for non-thyroid pathology). Identification of suspicious thyroid nodules results in further diagnostic work-up including laboratory assessment, further imaging, and biopsy. Accurate diagnosis is required for clinical staging and optimal patient treatment design. In this review, we aim to discuss utility of various imaging modalities and their role in thyroid cancer diagnosis and management. Additionally, we aim to highlight emerging diagnostic techniques that aim to improve diagnostic specificity and accuracy in thyroid cancer, thus paving way for precision medicine.
Collapse
Affiliation(s)
- Kimberley-Jane Bonjoc
- Department of Imaging Administration, City of Hope National Medical Center, Duarte, CA, USA
| | - Hannah Young
- Department of Imaging Administration, City of Hope National Medical Center, Duarte, CA, USA
| | - Susanne Warner
- Department of Surgery, City of Hope National Medical Center, Duarte, CA, USA
| | - Thomas Gernon
- Department of Surgery, City of Hope National Medical Center, Duarte, CA, USA
| | - Ellie Maghami
- Department of Surgery, City of Hope National Medical Center, Duarte, CA, USA
| | - Ammar Chaudhry
- Department of Diagnostic Radiology, City of Hope National Medical Center, Duarte, CA, USA
| |
Collapse
|
8
|
Abstract
In academic centers, PET/MR has taken the road to clinical nuclear medicine in the past 6 years since the last review on its applications in head and neck cancer patients in this journal. Meanwhile, older sequential PET + MR machines have largely vanished from clinical sites, being replaced by integrated simultaneous PET/MR scanners. Evidence from several studies suggests that PET/MR overall performs equally well as PET/CT in the staging and restaging of head and neck cancer and in radiation therapy planning. PET/MR appears to offer advantages in the characterization and prognostication of head and neck malignancies through multiparametric imaging, which demands an exact preparation and validation of imaging modalities, however. The majority of available clinical PET/MR studies today covers FDG imaging of squamous cell carcinoma arising from a broad spectrum of locations in the upper aerodigestive tract. In the future, specific PET/MR studies are desired that address specific histopathological tumor entities, nonepithelial malignancies, such as major salivary gland tumors, squamous cell carcinomas arising in specific locations, and malignancies imaged with non-FDG radiotracers. With the advent of digital PET/CT scanners, PET/MR is expected to partake in future technical developments, such as novel iterative reconstruction techniques and deviceless motion correction for respiration and gross movement in the head and neck region. Owing to the still comparably high costs of PET/MR scanners and facility requirements on the one hand, and the concentration of multidisciplinary head and neck cancer treatment mainly at academic centers on the other hand, a more widespread use of this imaging modality outside major hospitals is currently limited.
Collapse
|
9
|
Weber M, Binse I, Nagarajah J, Bockisch A, Herrmann K, Jentzen W. The role of 124I PET/CT lesion dosimetry in differentiated thyroid cancer. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2019; 63:235-252. [DOI: 10.23736/s1824-4785.19.03201-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|