1
|
Duan H, Yan W. Visual fatigue a comprehensive review of mechanisms of occurrence, animal model design and nutritional intervention strategies. Crit Rev Food Sci Nutr 2023; 65:1631-1655. [PMID: 38153314 DOI: 10.1080/10408398.2023.2298789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2023]
Abstract
When the eyes work intensively, it is easy to have eye discomfort such as blurred vision, soreness, dryness, and tearing, that is, visual fatigue. Visual fatigue not only affects work and study efficiency, but long-term visual fatigue can also easily affect physical and mental health. In recent years, with the popularization of electronic products, although it has brought convenience to the office and study, it has also caused more frequent visual fatigue among people who use electronic devices. Moreover, studies have reported that the number of people with visual fatigue is showing a trend of increasing year by year. The range of people involved is also extensive, especially students, people who have been engaged in computer work and fine instruments (such as microscopes) for a long time, and older adults with aging eye function. More and more studies have proposed that supplementation with the proper nutrients can effectively relieve visual fatigue and promote eye health. This review discusses the physiological mechanisms of visual fatigue and the design ideas of animal experiments from the perspective of modern nutritional science. Functional food ingredients with the ability to alleviate visual fatigue are discussed in detail.
Collapse
Affiliation(s)
- Hao Duan
- College of Biochemical Engineering, Beijing Key Laboratory of Bioactive Substances and Functional Food, Beijing Union University, Beijing, China
| | - Wenjie Yan
- College of Biochemical Engineering, Beijing Key Laboratory of Bioactive Substances and Functional Food, Beijing Union University, Beijing, China
| |
Collapse
|
2
|
Asiedu K, Krishnan AV, Kwai N, Poynten A, Markoulli M. Conjunctival microcirculation in ocular and systemic microvascular disease. Clin Exp Optom 2023; 106:694-702. [PMID: 36641840 DOI: 10.1080/08164622.2022.2151872] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 11/09/2022] [Accepted: 11/21/2022] [Indexed: 01/16/2023] Open
Abstract
The conjunctival microcirculation is an accessible complex network of micro vessels whose quantitative assessment can reveal microvascular haemodynamic properties. Currently, algorithms for the measurement of conjunctival haemodynamics use either manual or semi-automated systems, which may provide insight into overall conjunctival health, as well as in ocular and systemic disease. These algorithms include functional slit-lamp biomicroscopy, laser doppler flowmetry, optical coherence tomography angiography, orthogonal polarized spectral imaging, computer-assisted intravitral microscopy, diffuse reflectance spectroscopy and corneal confocal microscopy. Furthermore, several studies have demonstrated a relationship between conjunctival microcirculatory haemodynamics and many diseases such as dry eye disease, Alzheimer's disease, diabetes, hypertension, sepsis, coronary microvascular disease, and sickle cell anaemia. This review aims to describe conjunctival microcirculation, its characteristics, and techniques for its measurement, as well as the association between conjunctival microcirculation and microvascular abnormalities in disease states.
Collapse
Affiliation(s)
- Kofi Asiedu
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Arun V Krishnan
- School of Clinical Medicine, University of New South Wales, Sydney, Australia
- Department of Neurology, Prince of Wales Hospital, Sydney, Australia
| | - Natalie Kwai
- School of Medical Sciences, University of sydney, Sydney, Australia
| | - Ann Poynten
- Department of Endocrinology, Prince of Wales Hospital, Sydney, Australia
| | - Maria Markoulli
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
3
|
Suchand Sandeep CS, Khairyanto A, Aung T, Vadakke Matham M. Bessel Beams in Ophthalmology: A Review. MICROMACHINES 2023; 14:1672. [PMID: 37763835 PMCID: PMC10536271 DOI: 10.3390/mi14091672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/29/2023]
Abstract
The achievable resolution of a conventional imaging system is inevitably limited due to diffraction. Dealing with precise imaging in scattering media, such as in the case of biomedical imaging, is even more difficult owing to the weak signal-to-noise ratios. Recent developments in non-diffractive beams such as Bessel beams, Airy beams, vortex beams, and Mathieu beams have paved the way to tackle some of these challenges. This review specifically focuses on non-diffractive Bessel beams for ophthalmological applications. The theoretical foundation of the non-diffractive Bessel beam is discussed first followed by a review of various ophthalmological applications utilizing Bessel beams. The advantages and disadvantages of these techniques in comparison to those of existing state-of-the-art ophthalmological systems are discussed. The review concludes with an overview of the current developments and the future perspectives of non-diffractive beams in ophthalmology.
Collapse
Affiliation(s)
- C. S. Suchand Sandeep
- Centre for Optical and Laser Engineering, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Ahmad Khairyanto
- Centre for Optical and Laser Engineering, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Tin Aung
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 169856, Singapore
- Duke-NUS Medical School, National University of Singapore, Singapore 169857, Singapore
| | - Murukeshan Vadakke Matham
- Centre for Optical and Laser Engineering, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
| |
Collapse
|
4
|
Retinal image blood vessel classification using hybrid deep learning in cataract diseased fundus images. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2023]
|
5
|
Capote-Puente R, Sánchez-González JM, Sánchez-González MC, Bautista-Llamas MJ. Evaluation of Celligent® Biomimetic Water Gradient Contact Lens Effects on Ocular Surface and Subjective Symptoms. Diagnostics (Basel) 2023; 13:diagnostics13071258. [PMID: 37046476 PMCID: PMC10093668 DOI: 10.3390/diagnostics13071258] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/20/2023] [Accepted: 03/26/2023] [Indexed: 03/30/2023] Open
Abstract
This study aimed to evaluate the non-invasive and subjective symptoms associated with Lehfilcon A water gradient silicone hydrogel contact lenses with bacterial and lipid resistance technology. A prospective, longitudinal, single-centre, self-controlled study was conducted among silicone hydrogel contact lens wearers. Non-invasive analysis of the pre-lens tear film was performed using the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA), and the meibomian glands were evaluated with the Cobra® HD infrared meibographer. After 30 days of contact lens wear, the subjects were re-evaluated to determine the changes in conjunctival redness, subjective dry eye disease, tear meniscus height, lipid pattern, and non-invasive break-up time. Results showed that the lipid layer thickness decreased significantly from 2.05 ± 1.53 to 0.92 ± 1.09 Guillon patterns, and the tear meniscus height decreased from 0.21 ± 0.04 to 0.14 ± 0.03. The mean pre-lens non-invasive break-up time (NIBUT) significantly increased from 15.19 ± 9.54 to 25.31 ± 15.81 s. The standard Patient Evaluation of Eye Disease (SPEED) score also decreased from 7.39 ± 4.39 to 5.53 ± 4.83. The results suggest that Lehfilcon A significantly reduced lipid and aqueous tear film volume but improved break-up time and subjective dry eye symptoms.
Collapse
Affiliation(s)
- Raúl Capote-Puente
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - José-María Sánchez-González
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - María Carmen Sánchez-González
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - María-José Bautista-Llamas
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| |
Collapse
|
6
|
Slit lamp polarized dermoscopy: a cost-effective tool to assess eyelid lesions. Int Ophthalmol 2022; 43:1103-1110. [PMID: 36083562 DOI: 10.1007/s10792-022-02505-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 08/28/2022] [Indexed: 10/14/2022]
Abstract
PURPOSE Dermoscopy is a complementary examination of skin lesions, which allows the observation of anatomical features invisible to the naked eye. Its use increases the diagnostic accuracy of skin tumors. The development of polarized dermoscopy allowed the observation of deeper skin structures, without the need of skin contact. The purpose of this study was to present a low-cost prototype through the adaptation of polarized lenses on a slit lamp in order to assess anatomical aspects invisible to conventional biomicroscopy in eyelid lesions. METHODS Twenty two eyelid lesions were documented using a prototype, compound of two polarizing filters, orthogonal to each other, adapted to a slit lamp with an integrated digital camera. Images of the eyelid lesions were also obtained with non-polarized biomicroscopy and with a portable dermatoscope, and were compared regarding anatomical aspects. RESULTS Anatomical structures imperceptible to conventional ophthalmic examination were evidenced using the polarized lenses, demonstrating that this tool can be useful to the ophthalmologist when assessing eyelid lesions. We have obtained high-quality images of the lesions. The slit lamp provided higher magnification, better focus control and easier assessment of eyelid lesions than the portable dermatoscope. CONCLUSION Ophthalmologists already use the slit lamp in their practice. The adaptation of polarized lenses to this device is a cost-effective, fast and non-invasive method that permits to improve the diagnostic accuracy of eyelid lesions, evidencing anatomical structures imperceptible to conventional ophthalmic examination.
Collapse
|
7
|
Yun Z, Xu Q, Wang G, Jin S, Lin G, Feng Q, Yuan J. EVA: Fully automatic hemodynamics assessment system for the bulbar conjunctival microvascular network. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 216:106631. [PMID: 35123347 DOI: 10.1016/j.cmpb.2022.106631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 01/07/2022] [Accepted: 01/09/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Conjunctival microcirculation has been used to quantitatively assess microvascular changes due to systemic disorders. The space between red blood cell clusters in conjunctival microvessels is essential for assessing hemodynamics. However, it causes discontinuities in vessel image segmentation and increases the difficulty of automatically measuring blood velocity. In this study, we developed an EVA system based on deep learning to maintain vessel segmentation continuity and automatically measure blood velocity. METHODS The EVA system sequentially performs image registration, vessel segmentation, diameter measurement, and blood velocity measurement on conjunctival images. A U-Net model optimized with a connectivity-preserving loss function was used to solve the problem of discontinuities in vessel segmentation. Then, an automatic measurement algorithm based on line segment detection was proposed to obtain accurate blood velocity. Finally, the EVA system assessed hemodynamic parameters based on the measured blood velocity in each vessel segment. RESULTS The EVA system was validated for 23 videos of conjunctival microcirculation captured using functional slit-lamp microscopy. The U-Net model produced the longest average vessel segment length, 158.03 ± 181.87 µm, followed by the adaptive threshold method and Frangi filtering, which produced lengths of 120.05 ± 151.47 µm and 99.94 ± 138.12 µm, respectively. The proposed method and one based on cross-correlation were validated to measure blood velocity for a dataset consisting of 30 vessel segments. Bland-Altman analysis showed that compared with the cross-correlation method (bias: 0.36, SD: 0.32), the results of the proposed method were more consistent with a manual measurement-based gold standard (bias: -0.04, SD: 0.14). CONCLUSIONS The proposed EVA system provides an automatic and reliable solution for quantitative assessment of hemodynamics in conjunctival microvascular images, and potentially can be applied to hypoglossal microcirculation images.
Collapse
Affiliation(s)
- Zhaoqiang Yun
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Qing Xu
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
| | - Gengyuan Wang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Shuang Jin
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
| | - Guoye Lin
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Qianjin Feng
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.
| | - Jin Yuan
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China.
| |
Collapse
|
8
|
A meta-analysis of variability in conjunctival microvascular hemorheology metrics. Microvasc Res 2022; 142:104340. [DOI: 10.1016/j.mvr.2022.104340] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 02/03/2022] [Accepted: 02/07/2022] [Indexed: 12/28/2022]
|
9
|
Huang Z, Yang J, Wang H, Pang CP, Chen H. Comparison of Digital Camera Real-Time Display with Conventional Teaching Tube for Slit Lamp Microscopy Teaching. Curr Eye Res 2021; 47:161-164. [PMID: 34224279 DOI: 10.1080/02713683.2021.1952606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE To compare slit-lamp microscopy teaching outcomes with digital camera real-time display and conventional teaching tube in undergraduate education of clinical ophthalmology. METHODS Thirty-seven Year 4 medical students were assigned to two groups for slit lamp microscopy teaching with digital camera real-time display (n = 18) and teaching tube (n = 19). The outcome measures included a 5-item questionnaire on their experience and the quality of slit lamp photos taken by the students. RESULTS The overall satisfaction score was significantly higher in the group of digital camera real-time display compared with the group of teaching tube (4.5 ± 0.5 vs. 4.2 ± 0.7, P = .013). The former group also achieved higher quality score of the slit-lamp photography (4.1 ± 0.3 vs. 3.6 ± 0.5, P = .002). CONCLUSIONS The digital camera real-time display attachment is more effective in undergraduate ophthalmic education over conventional slit-lamp teaching tube. It is also more favored by students and is thus highly recommended for clinical ophthalmology education.
Collapse
Affiliation(s)
- Zijing Huang
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China
| | - Jianling Yang
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China
| | - Hongxi Wang
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China
| | - Chi Pui Pang
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China.,Department of Ophthalmology and Visual Sciences, Chinese University of Hong Kong, Hong Kong, China
| | - Haoyu Chen
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China
| |
Collapse
|
10
|
Romano V, Steger B, Ahmad M, Coco G, Pagano L, Ahmad S, Zhao Y, Zheng Y, Kaye SB. Imaging of vascular abnormalities in ocular surface disease. Surv Ophthalmol 2021; 67:31-51. [PMID: 33992663 DOI: 10.1016/j.survophthal.2021.05.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 04/25/2021] [Accepted: 05/03/2021] [Indexed: 12/13/2022]
Abstract
The vascular system of the ocular surface plays a central role in infectious, autoimmune, inflammatory, traumatic and neoplastic diseases. The development, application, and monitoring of treatments for vascular abnormalities depends on the in vivo analysis of the ocular surface vasculature. Until recently, ocular surface vascular imaging was confined to biomicroscopic and color photographic assessment, both limited by poor reproducibility and the inability to image lymphatic vasculature in vivo. The evolvement and clinical implementation of innovative imaging modalities including confocal microscopy, intravenous, and optical coherence tomography-based angiography now allows standardized quantitative and functional vascular assessment with potential applicability to automated analysis algorithms and diagnostics.
Collapse
Affiliation(s)
- Vito Romano
- Corneal and External Eye Disease Service, The Royal Liverpool University Hospital, Liverpool, UK; Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK.
| | - Bernhard Steger
- Department of Ophthalmology, Medical University of Innsbruck, Innsbruck, Austria
| | - Mohammad Ahmad
- Corneal and External Eye Disease Service, The Royal Liverpool University Hospital, Liverpool, UK
| | - Giulia Coco
- Corneal and External Eye Disease Service, The Royal Liverpool University Hospital, Liverpool, UK; Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Luca Pagano
- Corneal and External Eye Disease Service, The Royal Liverpool University Hospital, Liverpool, UK; Humanitas Clinical and Research, Rozzano (Mi) Italy
| | | | - Yitian Zhao
- Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK; Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China
| | - Yalin Zheng
- Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | - Stephen B Kaye
- Corneal and External Eye Disease Service, The Royal Liverpool University Hospital, Liverpool, UK; Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| |
Collapse
|
11
|
Conjunctival Vessels in Diabetes Using Functional Slit Lamp Biomicroscopy. Cornea 2020; 40:950-957. [PMID: 33332897 DOI: 10.1097/ico.0000000000002623] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 10/12/2020] [Indexed: 01/22/2023]
Abstract
PURPOSE This study used functional slit lamp biomicroscopy (FSLB) to quantify conjunctival microvessel parameters in individuals with and without diabetes and examined whether these metrics could be used as surrogate markers of diabetes-related complications. METHODS A cross-sectional study of 98 controls (C), 13 individuals with diabetes without complications (D-C), and 21 with diabetes and related complications (D+C), which included retinopathy, nephropathy, neuropathy, and cardiovascular-, peripheral vascular-, and cerebrovascular diseases, was performed. Bulbar conjunctival metrics (venule diameter, length, axial velocity [Va], cross-sectional velocity [Vs], flow [Q], and branching complexity) were measured using FSLB (digital camera mounted on traditional slit lamp). RESULTS The mean age was 60 ± 11 years, and demographics were similar across the groups. Va and Vs significantly differed between groups. Va was 0.51 ± 0.17 mm/s, 0.62 ± 0.17 mm/s, and 0.45 ± 0.17 mm/s in the C, D-C, and D+C groups, respectively (P = 0.025). Similarly, Vs was 0.35 ± 01.12, 0.43 ± 0.13, and 0.32 ± 0.13 mm/s in the C, D-C, and D+C groups, respectively (P = 0.031). Black individuals had increased Va, Vs, and Q compared with White individuals (P < 0.05), but differences in velocities persisted after accounting for race. Among patients with diabetes, Va and Vs correlated with number of organ systems affected (Va: ρ = -0.42, P = 0.016; Vs: ρ = -0.41, P = 0.021). Va, Vs, and Q significantly (P ≤ 0.005) discriminated between diabetic patients with and without complications (area under the receiver operating curve for Va = 0.81, Vs = 0.79, Q = 0.81). CONCLUSIONS Bulbar conjunctival blood flow metrics measured by FSLB differed between controls, diabetic patients without complications, and diabetic patients with complications. FSLB is a quick, easily accessible, and noninvasive alternative that might estimate the burden of vascular complications in diabetes.
Collapse
|
12
|
Liu Z, Jiang H, Townsend JH, Wang J. Improved conjunctival microcirculation in diabetic retinopathy patients with MTHFR polymorphisms after Ocufolin™ Administration. Microvasc Res 2020; 132:104066. [PMID: 32860770 DOI: 10.1016/j.mvr.2020.104066] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 08/25/2020] [Accepted: 08/25/2020] [Indexed: 12/19/2022]
Abstract
PURPOSE To investigate conjunctival microvascular responses in patients with mild diabetic retinopathy (MDR) and methylenetetrahydrofolate reductase (MTHFR) polymorphisms (D + PM) after administration of Ocufolin™, a medical food containing 900 μg l-methylfolate (levomefolate calcium or [6S]-5-methyltetrahydrofolic acid, calcium salt), methylcobalamin, and other ingredients. METHODS Eight D + PM patients received Ocufolin™ for six months (6 M). Bulbar conjunctival microvasculature and microcirculation metrics, including vessel diameter (D), axial blood flow velocity (Va), cross-sectional blood flow velocity (Vs), flow rate (Q), and vessel density (VD, Dbox), were measured at baseline, 4 M, and 6 M. RESULTS The mean age was 54 ± 7 years. No significant demographic differences were found. Conjunctival microcirculation, measured as Va, Vs, and Q was significantly increased at 4 M and 6 M, compared to baseline. Va was 0.44 ± 0.10 mm/s, 0.58 ± 0.13 mm/s, 0.59 ± 0.13 mm/s in baseline, 4 M, and 6 M, respectively (P < 0.01). Similarly, Vs was 0.31 ± 0.07 mm/s, 0.40 ± 0.09 mm/s, 0.41 ± 0.09 mm/s in baseline, 4 M, and 6 M, respectively (P < 0.05). Q was 107.8 ± 49.4 pl/s, 178.0 ± 125.8 pl/s, 163.3 ± 85.8 mm/s in baseline, 4 M, and 6 M, respectively (P < 0.05). The VD at 6 M was significantly higher than that at baseline (P = 0.017). Changes of D were positively correlated with changes of Va, Q, and VD. Effects of MTHFR and haptoglobin polymorphisms on the improvements of conjunctival microcirculation and microvasculature were found. CONCLUSIONS Ocufolin™ supplementation improves conjunctival microcirculation in patients with diabetic retinopathy and common folate polymorphisms.
Collapse
Affiliation(s)
- Zhiping Liu
- Ophthalmic Center, the Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China; Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, USA
| | - Hong Jiang
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, USA; Department of Neurology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Justin H Townsend
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, USA
| | - Jianhua Wang
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, USA.
| |
Collapse
|