1
|
Hengerer FH, Auffarth GU, Conrad-Hengerer I. 7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage. Adv Ther 2024; 41:1481-1495. [PMID: 38363465 PMCID: PMC10960914 DOI: 10.1007/s12325-024-02788-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/17/2024] [Indexed: 02/17/2024]
Abstract
INTRODUCTION This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma. METHODS This prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups. RESULTS Over 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up. CONCLUSION iStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.
Collapse
Affiliation(s)
- Fritz H Hengerer
- David J Apple International Laboratory of Ophthalmic Pathology, Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), Buergerhospital, University of Heidelberg, Frankfurt, Germany.
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ina Conrad-Hengerer
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
2
|
Gillmann K, Hornbeak DM. Rates of visual field change and functional progression in glaucoma following trabecular microbypass implantation of iStent technologies: a meta-analysis. BMJ Open Ophthalmol 2024; 9:e001575. [PMID: 38360043 PMCID: PMC10875546 DOI: 10.1136/bmjophth-2023-001575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 01/30/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND/AIM While intraocular pressure (IOP) remains the only modifiable risk factor for glaucoma progression, the ultimate goal of glaucoma management is to preserve patients' functional vision and quality of life. To this end, minimally invasive glaucoma surgeries (MIGSs) aim to reduce IOP with minimal eye trauma. Commonly used MIGS devices include iStent technologies, which have well-documented IOP-reducing potential and favourable safety profiles. However, no study concluded on their effect on the rates of visual field (VF) changes. The aim of this meta-analysis is to determine the long-term effect of iStent technology implantation on glaucoma functional progression. METHODS Electronic medical literature databases were searched to identify studies reporting on iStent technologies. Reports with follow-up durations <12 months, retention rates <75% and missing VF data were excluded. Fifteen studies reporting on 1115 eyes were identified. The overall weighted mean VF mean deviation (MD) progression, IOP reduction and follow-up duration were calculated. RESULTS Weighted mean IOP at baseline was 19.0±3.1 mm Hg. At the end of a 37.9-month mean follow-up (range 12-96 months), a weighted mean 26.6% IOP reduction was achieved (range 15.2%-42.3%). Over the same duration, the weighted mean VF MD progression rate was -0.02±0.34 dBs/year, from a mean baseline of -5.76±5.68 dBs. CONCLUSION In this review, which examines functional stability of 1115 eyes, iStent technologies achieved a mean rate of progression of -0.024 dBs/year with serial standard automated perimetry, which is similar to that reported in non-glaucomatous eyes and slower than that reported in medically treated glaucoma.
Collapse
Affiliation(s)
- Kevin Gillmann
- Genève Ophtalmologie, Geneva, Switzerland
- Stanford University, Palo Alto, California, USA
| | | |
Collapse
|
3
|
Khaimi MA, Koerber N, Ondrejka S, Gallardo MJ. Consistency in Standalone Canaloplasty Outcomes Using the iTrack Microcatheter. Clin Ophthalmol 2024; 18:173-183. [PMID: 38250597 PMCID: PMC10799572 DOI: 10.2147/opth.s441113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 01/05/2024] [Indexed: 01/23/2024] Open
Abstract
Purpose To study the consistency in outcomes of standalone canaloplasty performed via an ab-interno surgical technique in reducing intraocular pressure (IOP) and number of medications in uncontrolled open-angle glaucoma (OAG) eyes over a 12-month period. Methods This retrospective multicenter case series included patients who underwent standalone canaloplasty via an ab-interno surgical technique using the iTrack microcatheter (Nova Eye, Inc., Fremont, USA) and had preoperative uncontrolled OAG (IOP≥18mmHg) along with no previous glaucoma surgery. The iTrack microcatheter is used to circumnavigate 360° and viscodilate Schlemm's canal. Consistency of IOP and medications reduction on an eye-by-eye basis were evaluated to understand the outcomes in each single eye. Results Sixty-four eyes of 60 patients (age 71.5±13.4 years) were included. Six eyes (9%) that underwent additional glaucoma surgery were considered a failure and were subsequently excluded from analysis. At 12 months, IOP was reduced in 57 of the 58 (89%) remaining eyes; one eye had the same IOP with a reduced number of medications. Of the 57/58 eyes with a reduced IOP: 44 eyes (69%) required fewer medications; 12 eyes (19%) required the same number of medications. Of these 58 eyes, 78% of eyes had a ≥20% reduction in IOP compared to baseline; 69% eyes had a postoperative IOP ≤15 mmHg, and 86% eyes ≤18 mmHg at 12 months. Forty percent of the eyes were medication-free at 12 months compared to none at baseline. Conclusion Canaloplasty performed via an ab-interno surgical technique as a standalone procedure consistently reduced IOP and glaucoma medications in almost all eyes.
Collapse
Affiliation(s)
- Mahmoud A Khaimi
- Dean McGee Eye Institute – Oklahoma Health Center, Oklahoma City, OK, USA
| | | | | | | |
Collapse
|
4
|
Kim M, Rho S, Lim SH. Five-Year Outcomes of Single Trabecular Microbypass Stent (iStent ®) Implantation with Phacoemulsification in Korean Patients. Ophthalmol Ther 2023; 12:3281-3294. [PMID: 37792244 PMCID: PMC10640437 DOI: 10.1007/s40123-023-00824-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 09/19/2023] [Indexed: 10/05/2023] Open
Abstract
INTRODUCTION This study reports the long-term intraocular pressure (IOP)-lowering efficacy and safety of a single trabecular microbypass stent (iStent®; Glaukos Corp., San Clemente, CA, USA) for medically controlled open-angle glaucoma in Korean patients. METHODS This retrospective observational study included 42 eyes of 35 patients with primary open-angle glaucoma (POAG). All subjects underwent single first-generation iStent® implantation with phacoemulsification by a single surgeon with 5 years follow-up. The primary outcomes were changes in IOP and the number of antiglaucoma medications compared to the preoperative values. The secondary outcome was the proportion of eyes with IOP ≤ 18 mmHg without medication, ≤ 15 mmHg without medication, and ≤ 18 mmHg with or without medication. Adverse events and need for secondary glaucoma surgery were also recorded. RESULTS The mean IOP decreased from 15.8 ± 2.8 to 13.8 ± 1.7 mmHg and the mean number of medications was reduced from 2.24 ± 1.18 to 0.83 ± 1.12, respectively, at year 5. At 3 and 5 years, 80.6% and 78.6% of eyes, respectively, were receiving fewer medications than preoperative numbers. In contrast, only 50% of eyes on four preoperative medications showed medication reductions at 5 years. At years 3 and 5, 61.3% and 53.5% of eyes achieved IOP ≤ 18 mmHg without medication, whereas 90.3% and 89.3% of eyes achieved ≤ 18 mmHg regardless of medication use, respectively. Four eyes required additional glaucoma surgery (two Ahmed glaucoma valve implantations, one trabeculectomy, and one XEN 45 Gel Stent implantation), and all were receiving four preoperative antiglaucoma medications. Transient IOP elevation (14.3%) was the most common complication, followed by five hyphema, one stent obstruction, one stent malposition, and one severe anterior chamber reaction. CONCLUSION This study demonstrated a good safety profile and sustained IOP reduction after the implantation of a single trabecular microbypass stent (iStent®) with phacoemulsification in Korean patients. The majority of subjects with POAG showed a relatively good response; however, eyes receiving a higher number of medications preoperatively (especially four medications) had difficulty achieving a low target IOP.
Collapse
Affiliation(s)
- Myungjin Kim
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, South Korea
| | - Seungsoo Rho
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, South Korea
| | - Su-Ho Lim
- Department of Ophthalmology, Daegu Veterans Health Service Medical Center, #60 Wolgok-Ro, Dalseo-Gu, Daegu, 42835, Republic of Korea.
| |
Collapse
|
5
|
Chan L, Moster MR, Bicket AK, Sheybani A, Sarkisian SR, Samuelson TW, Ahmed IIK, Miller-Ellis E, Smith OU, Cui QN. New Devices in Glaucoma. Ophthalmol Ther 2023; 12:2381-2395. [PMID: 37558818 PMCID: PMC10441989 DOI: 10.1007/s40123-023-00780-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 07/20/2023] [Indexed: 08/11/2023] Open
Abstract
Glaucoma remains a leading cause of blindness globally. Minimally invasive treatment techniques are rapidly expanding the availability of therapeutic options for glaucoma. These include devices aimed at enhancing outflow through the subconjunctival space, Schlemm's canal, and suprachoroidal space, sustained-release drug delivery devices, and extraocular devices aiming to reduce glaucomatous progression through other novel means. In this review, we provide an overview of several novel devices either newly available or in development for the medical and surgical management of glaucoma. Further studies are required to determine the long-term efficacy of these devices and how they will integrate into the current landscape of glaucoma management.
Collapse
Affiliation(s)
- Lilian Chan
- Department of Ophthalmology, Scheie Eye Institute, University of Pennsylvania Perelman School of Medicine, 51 North 39th St., Philadelphia, PA, 19104, USA
| | | | - Amanda K Bicket
- Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, Medical School, University of Michigan, 1000 Wall St, Ann Arbor, MI, 48105, USA
| | - Arsham Sheybani
- Washington University School of Medicine, 660 South Euclid Ave, Campus Box 8096, St Louis, MO, 63110, USA
| | - Steven R Sarkisian
- Oklahoma Eye Surgeons, 5600 N Portland Ave, Oklahoma City, OK, 73112, USA
| | - Thomas W Samuelson
- Minnesota Eye Consultants, University of Minnesota, 909 Fulton St SE, Minneapolis, MN, 55455, USA
| | - Iqbal Ike K Ahmed
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada
- Prism Eye Institute, Mississauga, Canada
- John A. Moran Eye Center, University of Utah, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA
| | - Eydie Miller-Ellis
- Department of Ophthalmology, Scheie Eye Institute, University of Pennsylvania Perelman School of Medicine, 51 North 39th St., Philadelphia, PA, 19104, USA
| | - Oluwatosin U Smith
- Glaucoma Associates of Texas, 10740 N. Central Expy, Suite 300, Dallas, TX, 75231, USA
| | - Qi N Cui
- Department of Ophthalmology, Scheie Eye Institute, University of Pennsylvania Perelman School of Medicine, 51 North 39th St., Philadelphia, PA, 19104, USA.
| |
Collapse
|
6
|
Salimi A, Kasner O, Schendel S, Mydlarski M, Kalache D, Vera L, Pintwala R, Harasymowycz P. Outcomes and risk factors for Kahook Dual Blade excisional goniotomy with concomitant phacoemulsification: a multicentre Canadian study. CANADIAN JOURNAL OF OPHTHALMOLOGY 2023:S0008-4182(23)00249-1. [PMID: 37634551 DOI: 10.1016/j.jcjo.2023.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 07/04/2023] [Accepted: 08/11/2023] [Indexed: 08/29/2023]
Abstract
OBJECTIVE To assess the outcomes and failure risk factors for Kahook Dual Blade (KDB) excisional goniotomy with cataract surgery (phaco-KDB) in eyes with various glaucoma subtypes and severities. METHODS This multisurgeon consecutive case series included glaucomatous eyes with cataract that underwent phaco-KDB and had a minimum follow-up of 12 months postoperatively. Efficacy was assessed by absolute and qualified surgical success (defined by different criteria) and changes in intraocular pressure (IOP) and antiglaucoma medication (AGM) at the last postoperative follow-up. Safety included best-corrected visual acuity, cup-to-disc ratio, visual field mean deviation, retinal nerve fibre layer thickness, and adverse events. RESULTS A total of 108 eyes of 89 patients with a median follow-up of 18 months (range, 12-47 months) were included. IOP decreased by 26% from 19.1 ± 5.0 mm Hg to 14.1 ± 3.5 mm Hg (p < 0.001), AGM use decreased by 29% from 2.4 ± 1.3 medications to 1.7 ± 1.3 (p < 0.001), and 25% of eyes became free of AGMs (vs 3% at baseline). Qualified success rates achieved for IOP cutoffs of 18, 15, and 12 mm Hg were 87%, 68%, and 46%, respectively. Higher baseline IOP and postoperative incidence of IOP spikes were associated with a higher risk of surgical failure. Best-corrected visual acuity improved postoperatively (p < 0.001), and visual field mean deviation, cup-to-disc ratio, and retinal nerve fibre layer thickness remained stable. Overall, safety was favourable, and adverse events were transient and not sight threatening. CONCLUSION This multicentre Canadian study provides real-world data that support the safety and efficacy of phaco-KDB in reducing IOP and AGM use with no evidence of disease progression during the follow-up period.
Collapse
Affiliation(s)
- Ali Salimi
- Department of Ophthalmology, McGill University, Montreal, QC
| | - Oscar Kasner
- Department of Ophthalmology, McGill University, Montreal, QC; Ophthalmology Department, Jewish General Hospital, Montreal, QC
| | - Steven Schendel
- Department of Ophthalmology, University of British Columbia, Vancouver, BC
| | - Marc Mydlarski
- Department of Ophthalmology, McGill University, Montreal, QC; Ophthalmology Department, Jewish General Hospital, Montreal, QC
| | - Dima Kalache
- Department of Ophthalmology, Hospital Cité de la Santé, Laval, QC
| | - Lautaro Vera
- Department of Ophthalmology, McGill University, Montreal, QC
| | - Rob Pintwala
- Department of Ophthalmology, University of British Columbia, Vancouver, BC
| | - Paul Harasymowycz
- Montreal Glaucoma Institute and Bellevue Ophthalmology Clinics, Montreal, QC; Department of Ophthalmology, University of Montreal, Montreal, QC.
| |
Collapse
|
7
|
Gallardo MJ, Porter M. Efficacy and Safety of Pairing iStent Inject Trabecular Micro-Bypass and iAccess Precision Blade Goniotomy in Patients with Open-Angle Glaucoma. Ophthalmol Ther 2023; 12:1973-1987. [PMID: 37178443 PMCID: PMC10287603 DOI: 10.1007/s40123-023-00726-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023] Open
Abstract
INTRODUCTION This study evaluated efficacy and safety of implanting two second-generation trabecular micro-bypass stents (iStent inject/iStent inject W) with phacoemulsification, either with or without iAccess Precision Blade goniotomy, in patients with mild-to-moderate open-angle glaucoma (OAG). METHODS This retrospective, non-randomized, unmasked, dual-arm, single-site, multi-surgeon, consecutive case series evaluated all OAG eyes that underwent phacoemulsification and iStent inject implantation either as a dual procedure (group A) or paired with iAccess goniotomy (group B) from July 2020 to May 2022. Effectiveness outcomes analyzed from 1 month onward included intraocular pressure (IOP), proportions of eyes with IOP ≤ 12/≤ 15/≤ 18, proportion medication-free, and medication number. Safety outcomes at all timepoints included adverse events and secondary surgeries. RESULTS In group A, mean IOP reduced from 14.9 ± 3.2 mmHg on 1.22 ± 1.31 mean medications preoperatively (n = 63) to 13.5 ± 2.5 mmHg on 0.24 ± 0.61 medications at month 3 (n = 34; p = 0.048 IOP, p < 0.001 medications). In group B, mean IOP reduced from 16.0 ± 4.2 mmHg on 1.12 ± 1.07 medications preoperatively (n = 93) to 12.2 ± 2.3 mmHg on 0.57 ± 1.27 medications at month 3 (n = 23; p < 0.001 IOP, p = 0.003 medications). From preoperative to 3 months, the percent of eyes with IOP ≤ 12 mmHg remained at 32.4% in group A (p = 1.0) and rose from 21.7% to 60.9% in group B (p = 0.0177); eyes with IOP ≤ 15 mmHg rose from 52.9% to 76.5% in group A (p = 0.0963) and from 43.5% to 91.3% in group B (p = 0.0034). Adjusting for baseline between-group differences, group B had significantly greater postoperative IOP reduction than group A (p = 0.043); medication reductions were similar. Safety was favorable in both groups. CONCLUSIONS Phacoemulsification and iStent inject with or without iAccess Precision Blade goniotomy produced clinically meaningful and safe IOP and medication reductions. The paired iStent inject + iAccess + phacoemulsification procedure enabled greater IOP reduction and lower IOP thresholds than iStent inject + phacoemulsification. The study provides some of the first data on this paired approach and on the novel iAccess Precision Blade.
Collapse
Affiliation(s)
- Mark J. Gallardo
- El Paso Eye Surgeons, PA, 1201 North Mesa Street, Suite G, El Paso, TX 79902 USA
- Department of Ophthalmology, Texas Tech University Health Sciences Center in Lubbock, 3601, 4th St, Lubbock, TX 79430 USA
| | - Matthew Porter
- El Paso Eye Surgeons, PA, 1201 North Mesa Street, Suite G, El Paso, TX 79902 USA
- Department of Ophthalmology, Texas Tech University Health Sciences Center in Lubbock, 3601, 4th St, Lubbock, TX 79430 USA
| |
Collapse
|
8
|
Wagner IV, Ang B, Checo L, Simsek D, Draper C, Dorairaj S. Spotlight on Schlemm's Canal MicroStent Injection in Patients with Glaucoma. Clin Ophthalmol 2023; 17:1557-1564. [PMID: 37288002 PMCID: PMC10243342 DOI: 10.2147/opth.s388293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 05/30/2023] [Indexed: 06/09/2023] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) has revolutionized glaucoma care with its favorable safety profile and ability to delay or minimize the need for traditional, bleb-based procedures. Microstent device implantation is a type of angle-based MIGS, which reduces intraocular pressure (IOP) through bypass of the juxtacanalicular trabecular meshwork (TM) and facilitation of aqueous outflow into the Schlemm's canal. Although there are limited microstent devices on the market, multiple studies have evaluated the safety and efficacy of iStent® (Glaukos Corp.), iStent Inject® (Glaukos Corp.), and Hydrus® Microstent (Alcon) in the treatment of mild-to-moderate open-angle glaucoma, with and without concurrent phacoemulsification. This review attempts to provide a comprehensive evaluation of injectable angle-based microstent MIGS devices in the treatment of glaucoma.
Collapse
Affiliation(s)
| | - Bryan Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, Singapore
| | - Leticia Checo
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| | - Derya Simsek
- Department of Ophthalmology, Baskent University Medical School, Ankara, Turkey
| | | | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| |
Collapse
|
9
|
Kahale F, Chanbour W, El Zein L, Brenner J, You JY, Melki S. Phacoemulsification with and without iStent: A Systematic Review and Meta-Analysis of Comparative Studies. Ophthalmic Res 2023; 66:1020-1029. [PMID: 37245507 DOI: 10.1159/000531077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 05/09/2023] [Indexed: 05/30/2023]
Abstract
BACKGROUND The iStent (Glaukos Corporation; Laguna Hills, CA, USA) is one of the minimally invasive glaucoma devices. It can be inserted at the time of phacoemulsification or as a stand-alone procedure to lower the intraocular pressure (IOP). OBJECTIVE Our aim was to conduct a systematic review and meta-analysis comparing the effect of iStent insertion at the time of phacoemulsification with phacoemulsification alone in patients with ocular hypertension or open-angle glaucoma. METHODS We searched EMBASE, MEDLINE (OVID and PubMed), CINAHL, and Cochrane Library for articles published between 2008 and June 2022 (PRISMA 2020 for the checklist). Studies comparing the IOP-lowering effect of iStent with phacoemulsification versus phacoemulsification alone were included. The endpoints were IOP reduction (IOPR) and the mean reduction in the number of glaucoma drops. A quality-effects model was used to compare both surgical groups. RESULTS Ten studies were included, reporting on 1,453 eyes. Eight hundred fifty three eyes had the combined iStent and phacoemulsification, and 600 eyes underwent phacoemulsification alone. IOPR was higher in the combined surgery at of 4.7 ± 2 mm Hg compared to 2.8 ± 1.9 mm Hg in phacoemulsification alone. A greater decrease in postoperative eye drops was noted in the combined group having a decrease of 1.2 ± 0.3 eye drops versus of 0.6 ± 0.6 drops in isolated phacoemulsification. The quality effect model showed an IOPR weighted mean difference (WMD) of 1.22 mm Hg (confidence interval [CI]: [-0.43, 2.87]; Q = 315.64; p < 0.01; I2 = 97%) and decreased eye drops WMD 0.42 drops (CI: [0.22, 0.62]; Q = 42.6; p < 0.01; I2 = 84%) between both surgical groups. Subgroup analysis shows that the new generation iStent may be more effective in reducing IOP. CONCLUSION iStent has a synergetic effect with phacoemulsification. The reduction of IOP and glaucoma eye drops was higher when iStent is combined with phacoemulsification compared with isolated phacoemulsification.
Collapse
Affiliation(s)
| | - Wassef Chanbour
- Department of Ophthalmology and Visual Neurosciences, University of Minnesota, Minneapolis, Minnesota, USA
| | | | | | - Jae Young You
- Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
| | - Samir Melki
- Boston vision, Brookline, Massachusetts, USA
| |
Collapse
|
10
|
Effectiveness and Safety of iStent Infinite Trabecular Micro-Bypass for Uncontrolled Glaucoma. J Glaucoma 2023; 32:9-18. [PMID: 36260288 PMCID: PMC9722368 DOI: 10.1097/ijg.0000000000002141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 10/07/2022] [Indexed: 01/24/2023]
Abstract
PRCIS The iStent Infinite Trabecular Micro-Bypass System implanted in patients with open angle glaucoma (OAG) (uncontrolled by prior surgical or medical therapy) was effective in reducing mean diurnal intraocular pressure with a favorable safety profile. PURPOSE The purpose of this study is to evaluate safety and effectiveness of the iStent infinite Trabecular Micro-Bypass System in patients with OAG uncontrolled by prior surgical or medical therapy. DESIGN Prospective, multicenter, single-arm, open-label clinical trial. METHODS Implantation of iStent infinite (3 iStent inject W stents) was performed as a stand-alone surgical procedure in eyes with OAG uncontrolled by prior incisional or cilioablative surgeries or maximum tolerated medical therapy (MTMT). Prospectively declared effectiveness endpoints were proportion of eyes achieving ≥20% mean diurnal intraocular pressure (MDIOP) reduction from baseline at month 12 on the same or fewer intraocular pressure (IOP)-lowering medication classes (responder endpoint) and mean change in MDIOP from baseline at month 12. Safety parameters included visual acuity, slit-lamp and fundus examinations, gonioscopy, perimetry, surgical complications, and adverse events. RESULTS Seventy-two eyes of 72 patients (mean age 71.9 y) with preoperative mean medicated MDIOP of 23.4±2.8 mm Hg on a mean of 3.1±0.9 IOP-lowering medication classes were enrolled: 61 eyes with failed prior surgery/ies (Failed-Surgery subgroup) and 11 eyes uncontrolled on MTMT (MTMT subgroup). A total of 76.1% of all enrolled patients met the responder endpoint (73.4% Failed-Surgery, 90.9% MTMT), with mean reduction (SE) in MDIOP at month 12 of 5.9(0.6) mm Hg [5.5(0.7) mm Hg Failed-Surgery subgroup, 8.1(0.9) mm Hg MTMT subgroup]. For patients on the same or fewer medication(s) as baseline, 53.0% achieved ≥30% MDIOP reduction without surgical interventions/other events. Safety was favorable, with no explants, infection, or device-related interventions or hypotony. CONCLUSIONS iStent infinite stand-alone surgery achieved clinically significant IOP reduction and favorable safety in patients with OAG uncontrolled by prior therapy.
Collapse
|
11
|
Inatani M, Kohama I, Chu A. iStent Trabecular Micro-bypass Stent Implantation Combined with Phacoemulsification for Open-Angle Glaucoma: A 2-Year Post-marketing Surveillance Study in Japan. Adv Ther 2022; 39:4076-4093. [PMID: 35790641 PMCID: PMC9402767 DOI: 10.1007/s12325-022-02207-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/24/2022] [Indexed: 11/18/2022]
Abstract
Introduction We report 2-year outcomes after implantation of iStent trabecular micro-bypass stent with phacoemulsification, in Japanese patients with mild–moderate open-angle glaucoma (OAG). Methods This was a 24-month, prospective, longitudinal, observational, post-marketing study conducted between July 2017 and September 2020. Patients consisted of adults with OAG on antiglaucoma medications who had cataract surgery combined with one iStent implantation. Outcome measures included intraocular pressure (IOP), antiglaucoma medications, treatment success rates (defined as eyes having lower IOP with same or reduced number of medications from baseline, or same IOP with reduced number of medications from baseline, and not requiring secondary glaucoma surgeries postoperatively), and safety. Outcomes were analyzed in the overall cohort and in glaucoma subtypes: primary OAG, normal-tension glaucoma, and exfoliative glaucoma. Results Overall, 232 eyes were enrolled. At 24 months, mean ± standard deviation IOP decreased from 17.6 ± 4.0 mmHg preoperatively to 14.3 ± 3.0 mmHg (p < 0.05), and mean number of medications reduced from 2.2 ± 1.2 preoperatively to 0.7 ± 1.2 (p < 0.05). Similar trends were observed across glaucoma subtypes. In the overall cohort, 96.7%, 95.3%, and 93.7% of patients achieved treatment success at 6, 12, and 24 months, respectively. There were 67.6% medication-free eyes at 24 months compared to 3.2% medication-free eyes preoperatively (p < 0.0001). Safety profile was favorable over the 2-year period. Conclusions Following iStent implantation with phacoemulsification, clinically relevant and statistically significant reductions in IOP and number of medications were observed in Japanese eyes with OAG over 2 years, with favorable safety profile. These reductions were observed across all glaucoma subtypes. Supplementary Information The online version contains supplementary material available at 10.1007/s12325-022-02207-0.
Collapse
Affiliation(s)
- Masaru Inatani
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Eiheiji, Yoshida, Fukui, 910-1193, Japan.
| | | | - Alice Chu
- Glaukos Corporation, Singapore, Singapore
| |
Collapse
|