1
|
Khanafer A, Lobsien D, Sirakov A, Almohammad M, Schüngel MS, Pielenz D, Borgmann T, Hajiyev K, Bäzner H, Ganslandt O, Hennersdorf F, Cohen JE, Felber S, Schob S, Kemmling A, Sirakov S, Forsting M, Klisch J, Henkes H. Flow diversion with hydrophilic polymer coating with prasugrel as single antiplatelet therapy in the treatment of acutely ruptured intracranial aneurysms: a multicenter case series, complication and occlusion rates. J Neurointerv Surg 2025:jnis-2024-021831. [PMID: 39097404 DOI: 10.1136/jnis-2024-021831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Accepted: 06/21/2024] [Indexed: 08/05/2024]
Abstract
BACKGROUND This study reports a multicenter experience of using hydrophilic polymer-coated (HPC) flow diverters with prasugrel single antiplatelet therapy to treat ruptured aneurysms with subarachnoid hemorrhage (SAH). METHODS Patients treated for intracranial aneurysms within 30 days after SAH with a p64/p48 MW HPC flow diverter were prospectively identified. Clinical presentation and outcomes, periprocedural and postprocedural complications, and degree of occlusion at follow-up were evaluated. RESULTS A total of 84 patients were treated in 88 sessions (54.5% women; mean age 53.3 years). Four patients (4.7%) experienced flow diverter-dependent complications. No cases of aneurysm re-rupture or hemorrhagic complications related to antiplatelet therapy were recorded. Immediate complete occlusion was achieved in 27.4% of cases (23/84). The rate of complete occlusion among survivors was 83% in early follow-up, 90.2% in mid-term follow-up, and 92.3% in the latest possible follow-up. CONCLUSION p64/p48 MW HPC flow diverters with prasugrel single antiplatelet therapy were associated with safety from aneurysm re-rupture and high occlusion rates at medium- and long-term follow-up in managing ruptured aneurysms. Adequate management of single antiplatelet therapy with prasugrel is crucial, particularly with higher doses than usual, to avoid both ischemic and hemorrhagic complications.
Collapse
Affiliation(s)
- Ali Khanafer
- Neuroradiology, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany
| | - Donald Lobsien
- Neuroradiology, Helios Klinikum Erfurt, Erfurt, Thüringen, Germany
| | - Alexander Sirakov
- Radiology Department, University Hospital St Ivan Rilski, Sofia, Bulgaria
| | | | | | - Daniel Pielenz
- Neuroradiology, Helios Klinikum Erfurt, Erfurt, Thüringen, Germany
| | - Thomas Borgmann
- Department of Radiology, Barmherzige Brüder Krankenhaus Regensburg, Regensburg, Germany
| | - Kamran Hajiyev
- Neuroradiology, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany
| | - Hansjörg Bäzner
- Klinik für Neurologie, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany
| | - Oliver Ganslandt
- Klinik für Neurochirurgie, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany
| | - Florian Hennersdorf
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Tübingen, Tübingen, Germany
| | - José E Cohen
- Neurosurgery, Hadassah-Hebrew Univ Med Ctr, Jerusalem, Israel
| | - Stephan Felber
- Department of Diagnostic and Interventional Radiology Neuroradiology, Gemeinschaftsklinikum Koblenz Mayen, Koblenz, Germany
| | - Stefan Schob
- Department of Neuroradiology, University Hospital Halle, Halle, Germany
| | - André Kemmling
- Department of Neuroradiology, University Marburg, Marburg, Germany
| | - Stanimir Sirakov
- Radiology Department, University Hospital St Ivan Rilski, Sofia, Bulgaria
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Joachim Klisch
- Neuroradiology, Helios Klinikum Erfurt, Erfurt, Thüringen, Germany
| | - Hans Henkes
- Neuroradiology, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| |
Collapse
|
2
|
Krug N, Kirschke JS, Maegerlein C, Kreiser K, Wostrack M, Meyer B, Albrecht C, Zimmer C, Boeckh-Behrens T, Sepp D. Intracranial Aneurysms Treated with a Novel Coated Low-Profile Flow Diverter (p48 HPC)-A Single-Center Experience and an Illustrative Case Series. Brain Sci 2025; 15:42. [PMID: 39851410 PMCID: PMC11763383 DOI: 10.3390/brainsci15010042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2024] [Revised: 12/31/2024] [Accepted: 01/02/2025] [Indexed: 01/26/2025] Open
Abstract
Background/Objectives: The p48 MW HPC is a novel low-profile flow diverter covered by a hydrophilic polymer coating with antithrombogenic properties, which may reduce ischemic complications and enable a single antiplatelet therapy after insertion of the stent. In this single-center experience, we describe the efficacy of this device, focusing on the illustration of different therapeutic indications and the outcome in various clinical settings with regard to vessel anatomy, bleeding state, and aneurysm configuration. Methods: We retrospectively reviewed our database for all patients being treated with a p48 MW HPC flow diverter between February 2019 and July 2021. The efficacy of the treatment was evaluated according to the O'Kelly-Marotta (OKM) scale in the last digital subtraction angiography (DSA) follow-up. Information on complications and medications were collected from our medical records. In addition, to illustrate different indications and clinical settings, we present six of these cases in closer detail. Results: 18 aneurysms in 14 patients were treated with the p48 MW HPC flow diverter and in one case with an additional Derivo device. Periprocedural events occurred in 28.6% of the treated patients, which were all successfully resolved within the same session. Follow-up examination information was available for 67% of patients, of which 75% showed complete occlusion of the aneurysm and 83.3% showed a favorable occlusion result (OKM C-D). Two patients with ruptured aneurysms received a single antiplatelet therapy with ASA without thrombotic complications, at least in the short term. New braid deformation patterns were observed in 16.6% at the follow-up examination, but none with subsequent clinical significance. Conclusions: The p48 MW HPC is safe and effective in the treatment of a wide spectrum of differently configurated, ruptured, and unruptured aneurysms. Single antiplatelet therapy might be an option in selected cases.
Collapse
Affiliation(s)
- Nadja Krug
- Department of Neuroradiology, University Hospital Heidelberg, 69120 Heidelberg, Germany
| | - Jan S. Kirschke
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| | - Christian Maegerlein
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| | - Kornelia Kreiser
- Department of Radiology and Neuroradiology, University Hospital Ulm, 89081 Ulm, Germany
| | - Maria Wostrack
- Department of Neurosurgery, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| | - Bernhard Meyer
- Department of Neurosurgery, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| | - Carolin Albrecht
- Department of Neurosurgery, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| | - Claus Zimmer
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| | - Tobias Boeckh-Behrens
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| | - Dominik Sepp
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
| |
Collapse
|
3
|
Khanafer A, Almohammad M, von Gottberg P, Hajiyev K, Kemmling A, Forsting M, Henkes H. Stent retriever expansion as a corrective maneuver to optimize inadequately deployed flow diverter stents. Interv Neuroradiol 2024:15910199241302436. [PMID: 39655489 PMCID: PMC11629362 DOI: 10.1177/15910199241302436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2024] [Accepted: 10/23/2024] [Indexed: 12/12/2024] Open
Abstract
BACKGROUND AND PURPOSE As flow diversion (FD) is becoming increasingly important in the endovascular treatment of intracranial aneurysms, the rate of technical complications is also increasing. Inadequate FD implantation may lead to both ischemic complications and decreased treatment efficacy. The aim of this study was to evaluate the efficacy of off-label stent retriever (SR) use in managing technical complications associated with FD implantation. MATERIALS AND METHODS A retrospective analysis of data from patients who underwent FD treatment at two neuroradiology centers was performed. The objective was to identify cases in which the FD was inadequately deployed and SR expansion was performed as a corrective maneuver. The analysis included anatomic characteristics, technical information, angiographic and clinical outcomes, and complications. RESULTS A total of 35 corrective maneuvers with SR were performed in 25 FD treatments. The corrective maneuvers in all treatments were successful, and no additional devices or therapies were required. No procedural complications or technical difficulties were documented. CONCLUSION With the growing role of FDs in neurointerventional treatment, familiarity with corrective maneuvers after technical complications or inadequate implantation is important. The findings in our selected cohort demonstrated that SR expansion is an effective and safe corrective maneuver for incompletely opened FDs.
Collapse
Affiliation(s)
- A Khanafer
- Department of Neuroradiology, Klinikum Stuttgart, Stuttgart, Germany
| | - M Almohammad
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Marburg, Marburg, Germany
| | - P von Gottberg
- Department of Neuroradiology, Klinikum Stuttgart, Stuttgart, Germany
| | - K Hajiyev
- Department of Neuroradiology, Klinikum Stuttgart, Stuttgart, Germany
| | - A Kemmling
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Marburg, Marburg, Germany
| | - M Forsting
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - H Henkes
- Department of Neuroradiology, Klinikum Stuttgart, Stuttgart, Germany
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| |
Collapse
|
4
|
de Castro-Afonso LH, Machado JP, Nakiri GS, Abud TG, Monsignore LM, Freitas RK, de Oliveira RS, Colli BO, Abud DG. Two year follow-up of distal unruptured intracranial aneurysms treated with a surface modified flow diverter under prasugrel monotherapy. J Neurointerv Surg 2024; 16:1163-1166. [PMID: 37524519 DOI: 10.1136/jnis-2023-020397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Accepted: 07/21/2023] [Indexed: 08/02/2023]
Abstract
BACKGROUND A new generation of modified surface flow diverters (FDs) and monotherapy using new antiplatelets may reduce both ischemic and hemorrhagic complications during the treatment of intracranial aneurysms. Previous preliminary safety analysis of distal unruptured intracranial aneurysms treated with the FD p48 MW HPC (phenox-Wallaby, Bochum, Germany) under antiplatelet monotherapy with prasugrel showed promising results. However, the long term outcomes of distal intracranial aneurysms treated with FDs under antiplatelet monotherapy are not known. METHODS This was a single center, prospective, pivotal, open single arm study. The primary (safety) endpoint was absence of any new neurological deficits after treatment until the 24 month follow-up. The primary (efficacy) endpoint was the incidence of complete aneurysm occlusion 24 months after treatment. The secondary (efficacy) endpoints were any incidence of aneurysm dome reduction 24 months after treatment. RESULTS 21 patients harboring 27 distal aneurysms of the anterior circulation were included. No patient had neurologic deficits in the time from treatment to the 24 month follow-up. Complete aneurysm occlusion occurred in 20 (74%) of 27 aneurysms at the 24 month follow-up. Four aneurysms (14.8%) had dome reduction, and three aneurysms (11.1%) remained unchanged. CONCLUSIONS In this pilot trial, treatment of distal unruptured intracranial aneurysms with an FD under monotherapy with prasugrel, followed by monotherapy with aspirin, appeared to be safe and effective. Randomized studies with long term follow-up are needed to confirm these results.
Collapse
Affiliation(s)
- Luis Henrique de Castro-Afonso
- Interventional Neuroradiology, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
| | - João Paulo Machado
- Interventional Neuroradiology, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
| | - Guilherme Seizem Nakiri
- Interventional Neuroradiology, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
| | - Thiago Giansante Abud
- Interventional Neuroradiology, Hospital Israelita Albert Einstein, Sao Paulo, Brazil
| | - Lucas Moretti Monsignore
- Interventional Neuroradiology, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
| | - Rafael Kiyuze Freitas
- Interventional Neuroradiology, Hospital Israelita Albert Einstein, Sao Paulo, Brazil
| | - Ricardo Santos de Oliveira
- Division of Neurosurgery, Department of Surgery, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
| | - Benedicto Oscar Colli
- Division of Neurosurgery, Department of Surgery, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
| | - Daniel Giansante Abud
- Interventional Neuroradiology, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
| |
Collapse
|
5
|
Bilgin C, Senol YC, Kobeissi H, Orscelik A, Ghozy S, Oliver AA, Kadirvel R, Brinjikji W, Kallmes DF. Phenox HPC and Phenox flow modulation devices for the endovascular treatment of intracranial aneurysms: a systematic review and meta-analysis. J Neurointerv Surg 2024; 16:706-714. [PMID: 37536930 DOI: 10.1136/jnis-2023-020514] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 07/12/2023] [Indexed: 08/05/2023]
Abstract
BACKGROUND Surface-modified flow diverters are increasingly used in clinical settings. However, their safety profiles and additional benefits over non-coated devices still need to be explored. In this meta-analysis, we aimed to investigate and compare the clinical outcomes of the uncoated Phenox and coated Phenox HPC flow diverters. METHODS A systematic literature review was performed using PubMed, Scopus, Embase, and Web of Science databases. Collected data were pooled and corresponding 95% confidence intervals (CI) were calculated. Outcomes of interest included aneurysm occlusion (>6 months) and complication rates. Additionally, the safety outcomes of prophylactic single (SAPT) and dual antiplatelet treatment (DAPT) approaches were compared for patients treated with coated Phenox HPC flow diverters. RESULTS We included 17 studies with 1238 patients. The overall complete occlusion rates were 80% (95% CI 74.01% to 86.56%) for Phenox HPC and 71.3% (95% CI 59.71% to 85.20%) for non-coated Phenox flow diverters (p=0.24). Ischemic complication rates were 7.3% (95% CI 4.6% to 11.39%) with the Phenox HPC and 5.3% (95% CI 4.07% to 6.91%) with the Phenox (p=0.24). For patients treated with Phenox HPC, the SAPT (5.5%; 95% CI 2.83% to 10.85%) and DAPT (7.1%; 95% CI 1.23% to 41.45%) approaches resulted in comparable ischemic complication rates (p=0.79). The DAPT group (4.8%; 95% CI 1.46% to 16.24%) had higher hemorrhagic complication rates than the SAPT group (1.7%; 95% CI 0.52% to 6.09%), but the difference was not statistically significant for patients treated with Phenox HPC (p=0.25). CONCLUSIONS Our findings indicate that Phenox HPC is equally as safe and effective as non-coated Phenox devices. Additionally, our results suggest that prasugrel monotherapy might effectively prevent ischemic complications in patients treated with Phenox HPC flow diverters.
Collapse
Affiliation(s)
- Cem Bilgin
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Yigit Can Senol
- Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Hassan Kobeissi
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Atakan Orscelik
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Sherief Ghozy
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | - Waleed Brinjikji
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
- Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - David F Kallmes
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
6
|
Rodríguez-Fernández C, Ruiz-Garcia P, Garcia-Sanchez MJ, Manrique-Zegarra M, Toledano-Illán C, Escartin J, Vences MA, Rubio LA, Luttich A, Pumar JM. Technical success, procedural safety, and efficacy of the Silk Vista Baby in the treatment of cerebral aneurysms over a mid-to-long-term follow-up. Front Neurol 2024; 15:1369443. [PMID: 38638309 PMCID: PMC11025534 DOI: 10.3389/fneur.2024.1369443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 03/14/2024] [Indexed: 04/20/2024] Open
Abstract
Background Long-term follow-up of cerebral aneurysms treated with the Silk Vista Baby (SVB) flow diverter is lacking. This study aimed to assess the technical success, procedural safety, and efficacy of the SVB (Balt, Montmorency, France) for the treatment of intracranial aneurysms in small cerebral vessels over a mid-to long-term follow-up. Methods We retrospectively analyzed a prospectively maintained database of patients treated with the SVB between September 2018 and June 2021. Data regarding patient demographics, aneurysm characteristics, and technical procedures were also collected. Angiographic and clinical findings were recorded during the procedure and over a period of at least 12 months. Results Angiographic and clinical follow-up data were available for 50 patients/50 aneurysms. The procedural complication rate was 8%. At 12 months, the final results showed a technical success rate of 100%, the re rupture rate was 0%, neuromorbidity and mortality rates of 4 and 0%, respectively, and an almost complete occlusion rate of 94%. Conclusion Treatment of complex intracranial aneurysms with the SVB was safe and effective. Long-term results showed high rates of adequate and stable occlusions.
Collapse
Affiliation(s)
| | - Pedro Ruiz-Garcia
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | | | - Martiel Manrique-Zegarra
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Carlos Toledano-Illán
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Jorge Escartin
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Miguel Angel Vences
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
- School of Medicine, Universidad César Vallejo, Piura, Peru
| | - Luis Angel Rubio
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Alex Luttich
- Interventional Neuroradiology Department, Hospital Universitario Donostia, San Sebastian, Spain
| | - José Manuel Pumar
- Chair of Interventional Neuroradiology, University of Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
7
|
Hanel RA, Cortez GM, Benalia VHC, Sheffels E, Sutphin DJ, Pederson JM, Pereira VM. Patient outcomes after treatment of brain aneurysm in small diameter vessels with the silk vista baby flow diverter: A systematic review. Interv Neuroradiol 2024; 30:5-13. [PMID: 35392703 PMCID: PMC10956459 DOI: 10.1177/15910199221091645] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 03/16/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The Silk Vista Baby (SVB, BALT) is a first-in-class flow-diverter device delivered using a 0.017" microcatheter, designed for the treatment of intracranial aneurysms, including those in small diameter vessels. This study reports a systematic literature review (SLR) to evaluate the safety and efficacy of using SVB to treat intracranial aneurysms in vessels less than 3.5 mm in diameter. METHODS We performed a PRISMA-compliant SLR to evaluate the outcomes of SVB in the treatment of aneurysms in small intracranial vessels. Primary outcomes were occlusion status and major stroke, and secondary outcomes included all-cause mortality, procedure-related neurologic death, and post-operative aneurysm rupture. Data were expressed as descriptive statistics only. RESULTS A total of four studies, including 163 patients with 173 intracranial aneurysms, were included. The most common aneurysm locations were the anterior cerebral artery (24.9% [43/173]), the middle cerebral artery (24.3% [42/173]), and the anterior communicating artery (23.1% [40/173]). Parent artery diameter ranged from 0.9 mm to 3.6 mm, and 29% were acutely or previously ruptured aneurysms. Overall, complete or near-complete occlusion was 72.1% on early-term follow-up. Mortality rate among the studies was 2.5%, with 3 instances adjudicated as neurologic deaths (1.8%). Major stroke was noted in 1.2% of cases, and branch occlusion or stent thrombus formation in 5.5%. CONCLUSION Our review suggests that SVB is a safe and effective treatment for intracranial aneurysms in small vessels. Further prospective and comparative studies with patient outcome data specific to aneurysm location are needed to confirm the safety and efficacy of SVB.
Collapse
Affiliation(s)
- Ricardo A Hanel
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, FL, USA
| | - Gustavo M Cortez
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, FL, USA
- Research Department, Jacksonville University, Jacksonville, FL, USA
| | - Victor H C Benalia
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, FL, USA
- Research Department, Jacksonville University, Jacksonville, FL, USA
| | | | | | | | - Vitor M Pereira
- Departments of Surgery and Medical Imaging, Division of Neurosurgery, St Michaels Hospital, University of Toronto, Ontario, Canada
| |
Collapse
|
8
|
El Naamani K, Saiegh FA, Chen CJ, Abbas R, Sioutas GS, Amllay A, Shehabeldine M, Gooch MR, Herial NA, Jabbour P, Rosenwasser RH, Tjoumakaris SI. Treatment of cerebral aneurysms with the FRED Jr flow-diverting stent: A case series and meta-analysis. Clin Neurol Neurosurg 2022; 223:107483. [DOI: 10.1016/j.clineuro.2022.107483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 09/29/2022] [Accepted: 10/18/2022] [Indexed: 11/30/2022]
|
9
|
Bhogal P, Petrov A, Rentsenkhu G, Nota B, Ganzorig E, Regzengombo B, Jagusch S, Henkes E, Henkes H. Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment. Interv Neuroradiol 2021; 28:266-276. [PMID: 34233547 PMCID: PMC9178779 DOI: 10.1177/15910199211029503] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Background The p64MW HPC and p48MW HPC flow diverters have reduced thrombogenicity due
to hydrophilic coating. The purpose of this study was to evaluate its safety
and efficacy in Mongolian patients under single antiplatelet therapy (SAPT)
with prasugrel. Materials and methods We performed a retrospective review of patients enrolled into our
prospectively maintained database to identify all patients treated with
either the p48MW HPC or p64MW HPC under SAPT. We recorded baseline
demographics, aneurysm size and location, procedural complications,
angiographic and clinical results. Results 24 patients, (female = 21, 87.5%), age 48.2 ± 11.6 years (range 25–63)
underwent treatment of 30 aneurysms with either p64MW HPC or p48MW HPC. All
aneurysms were saccular with dome width 8.2 ± 6.5 (range 1.6–26.0 mm) and
dome height 7.6 ± 6.7 (range 1.6–30.0 mm). None of the aneurysms were
previously treated. The average PRU was 54.6 ± 31.2 (range 1–127) on
pre-operative VerifyNow testing. Angiographic follow-up was available for 13
patients (17 aneurysms), 183 ± 36 days post-procedure, at which point 64.7%
of aneurysms (n = 11/17) were completely occluded and 11.8% (n = 2/17) had
only neck remnants resulting in 76.5% of aneurysms being adequately occluded
A single intra-operative complication (4.2%) occurred however all patients
were mRS ≤1 at last follow-up. There were two post-operative complications
neither of which resulted in permanent neurological morbidity. There were no
instances of post-operative aneurysmal rupture or delayed parenchymal
haemorrhage. The overall mortality was 0%. Conclusion The efficacy and safety of p64MW HPC coated devices under SAPT is similar to
uncoated flow diverters that require DAPT.
Collapse
Affiliation(s)
| | - Andrey Petrov
- Vascular Neurosurgery Department, Russian Polenov Neurosurgical Institute, Branch of National Medical Research Center "Almazov", St. Petersburg, Russia
| | | | - Baatarjan Nota
- Department of Angiography, Shastin Central Hospital, Ulaanbaatar, Mongolia
| | - Erdenebat Ganzorig
- Department of Angiography, Shastin Central Hospital, Ulaanbaatar, Mongolia
| | | | | | - Elina Henkes
- Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany
| | - Hans Henkes
- Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany.,University Duisburg-Essen, Essen, Germany
| |
Collapse
|
10
|
Bhogal P, Makalanda H, Wong K, Keston P, Downer J, Du Plessis JC, Nania A, Simonato D, Fuschi M, Chong W, O'Reilly S, Rennie I. The Silk Vista Baby - The UK experience. Interv Neuroradiol 2021; 28:201-212. [PMID: 34078155 DOI: 10.1177/15910199211024061] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The Silk Vista Baby (SVB) flow diverter (FDS) is the only FDS deliverable via a 0.017 inch microcatheter and is specifically designed for the distal vasculature. We sought to evaluate the safety and efficacy of the SVB. MATERIALS AND METHODS We performed a retrospective review to identify SVB cases at 4 tertiary neurosurgical centres within the U.K. Clinical, procedural, angiographic and follow-up data were collected. RESULTS We identified 60 patients (35 female, 58%) of average age 54 ± 10.5 (range 30-72) with 61 aneurysms, 50 (81.9%) located in the anterior circulation. The majority of the aneurysms treated were unruptured (46, 75.4%) and saccular (46, 75.4%). Dome size was 6.2 ± 6.2 mm (range 1-36mm) and parent vessel diameter was 2.3 ± 0.4 mm (range 1.2-3.3 mm).An average number of 1.07 devices were implanted. Coils or other devices were implanted in 14 aneurysms (23.3%). At last angiographic follow-up (n = 55), 7.5 ± 4.2 months post-procedure, 32 aneurysms (57.1%) were graded as RRC I, 7 (12.5%) RRC II, and 17 RRC III (30.4%).Clinical complications, excluding death, were seen in 4 patients (6.8%) including 1 delayed aneurysm rupture and 3 symptomatic ischaemic events. Only one patient had permanent morbidity (mRS 1). 3 patients died during follow-up (5.1%); 2 deaths were related to the aneurysms (3.4%) - one ruptured dissecting MCA aneurysm, and one giant partially thrombosed posterior circulation aneurysm. 93% of patients were mRS ≤ 2 at last follow-up. CONCLUSION The SVB has high rates of technical success and an acceptable safety profile. Distal aneurysms may occlude slower due to relative oversizing of the devices.
Collapse
Affiliation(s)
- P Bhogal
- The Royal London Hospital, London, UK
| | | | - K Wong
- The Royal London Hospital, London, UK
| | - P Keston
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - J Downer
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - J C Du Plessis
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - A Nania
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - D Simonato
- Department of Interventional Neuroradiology, John Radcliffe Hospital, Oxford, UK
| | - M Fuschi
- Department of Interventional Neuroradiology, John Radcliffe Hospital, Oxford, UK
| | - W Chong
- Department of Interventional Neuroradiology, University Hospitals Coventry and Warwickshire, Warwickshire, UK
| | - S O'Reilly
- Department of Interventional Neuroradiology, The Royal Victoria Hospital, Belfast, UK
| | - I Rennie
- Department of Interventional Neuroradiology, The Royal Victoria Hospital, Belfast, UK
| |
Collapse
|
11
|
den Bergh FRAV, De Beule T, van Rooij WJ, Voormolen MH, Van der Zijden T, Stockx L, van Zwam WH, Fransen H. The p48 flow diverter: First clinical results in 25 aneurysms in three centers. Interv Neuroradiol 2021; 27:339-345. [PMID: 33164617 PMCID: PMC8190948 DOI: 10.1177/1591019920972213] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 10/13/2020] [Accepted: 10/18/2020] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND The novel low-profile p48 flow diverter has been designed to treat aneurysms on small vessels of 1.75-3mm. We report our first clinical experiences. METHODS Between March 2018-January 2020, 22 patients with 25 aneurysms were treated with the p48 in 3 centers. One patient had 3 aneurysms covered by one p48 and one patient had 2 aneurysms. There were 5 men, 17 women, with a mean age of 55 years (median 59, range 29-73 years). RESULTS In 25 aneurysms, 24 p48 flow diverters were placed. In 1 patient additional coils were placed in the aneurysm. Procedural vessel rupture by the micro guidewire occurred in 2 patients and vessel rupture during p48 balloon dilatation occurred in 1 patient. Overall, the permanent morbidity rate was 13.6% (3 of 22, 95%CI 3.9-34.2%) and mortality was 4.5% (1 of 22, 95%CI <0.01-23.5%). Most complications were procedure-related and not device-specific. Of 22 patients with 25 aneurysms treated with p48, 18 patients with 20 aneurysms had angiographic follow-up after 5-18 months. Of 19 aneurysms, 10 were occluded and 7 showed a remnant. Two aneurysms were open after 6 months. Three aneurysms were still not occluded after 12, 14, and 18 months and these 3 were retreated. Retreatment rate was 16% (3 of 19) and the adequate occlusion rate was 90% (17 of 19). CONCLUSIONS Treatment of aneurysms in small-caliber vessels with the p48 is feasible and effective but is not without complications. More data is needed to establish indications, safety, and efficacy more accurately.
Collapse
Affiliation(s)
- FRA Van den Bergh
- Department of Radiology, Algemeen Ziekenhuis St Lucas, Gent, Belgium
| | - T De Beule
- Department of Radiology, Ziekenhuis Oost-Limburg, Genk, Belgium
| | - WJ van Rooij
- Department of Radiology, Algemeen Ziekenhuis Turnhout, Turnhout, Belgium
| | - MH Voormolen
- Department of Radiology, Universitair Ziekenhuis Antwerpen, Edegem, Belgium
| | - T Van der Zijden
- Department of Radiology, Universitair Ziekenhuis Antwerpen, Edegem, Belgium
| | - L Stockx
- Department of Radiology, Ziekenhuis Oost-Limburg, Genk, Belgium
| | - WH van Zwam
- Department of Radiology, Maastricht Universiteit Medisch Centrum, Maastricht, the Netherlands
| | - H Fransen
- Department of Radiology, Algemeen Ziekenhuis St Lucas, Gent, Belgium
| |
Collapse
|
12
|
de Castro-Afonso LH, Nakiri GS, Abud TG, Monsignore LM, Freitas RK, de Oliveira RS, Colli BO, Dos Santos AC, Abud DG. Treatment of distal unruptured intracranial aneurysms using a surface-modified flow diverter under prasugrel monotherapy: a pilot safety trial. J Neurointerv Surg 2021; 13:647-651. [PMID: 33632882 DOI: 10.1136/neurintsurg-2020-017262] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 01/25/2021] [Accepted: 01/28/2021] [Indexed: 01/26/2023]
Abstract
BACKGROUND Flow diverters (FDs) are effective in the treatment of carotid aneurysms. Compared with carotid aneurysms, the treatment of distal intracranial aneurysms with FDs has been associated with a relatively high incidence of complications. Low thrombogenic modified-surface FDs may reduce ischemic complications and allow for the use of a single antiplatelet medication. The aim of this study was to assess the safety and efficacy of the p48 MW HPC Flow Modulation Device (Phenox GmbH, Bochum, Germany) to treat distal intracranial aneurysms used in combination with prasugrel monotherapy. METHODS This was a single-center, prospective, pivotal, open, single-arm study. Patients were included in this study from December 2019 to September 2020. The primary endpoints were the incidence of any neurologic deficit after treatment until 1 month of follow-up, defined as National Institutes of Health Stroke Scale (NIHSS) ≥1, and the incidence of acute ischemic lesions in magnetic resonance imagin (MRI) images 48 hours after treatment. The secondary endpoint was the rate of complete occlusion of the aneurysms at the 1-month follow-up. RESULTS Twenty-one patients harboring 27 distal aneurysms of the anterior circulation were included. Mean age was 57.8 (SD 9.7) years, and 16 patients were female (80%). No patient had neurologic symptoms at the 1-month follow-up. Four patients (20%) had asymptomatic acute brain ischemic lesions on MRI. Complete aneurysm occlusion occurred in 9/27 (33.3%) aneurysms at the 1-month follow-up. CONCLUSION In this pilot safety trial, treatment of distal intracranial aneurysms with p48 MW HPC under monotherapy with prasugrel appeared to be safe.
Collapse
Affiliation(s)
- Luis Henrique de Castro-Afonso
- Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| | - Guilherme Seizem Nakiri
- Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| | - Thiago Giansante Abud
- Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil.,Division of Interventional Neuroradiology, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
| | - Lucas Moretti Monsignore
- Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| | - Rafael Kiyuze Freitas
- Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| | - Ricardo Santos de Oliveira
- Division of Neurosurgery, Department of Surgery, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| | - Benedicto Oscar Colli
- Division of Neurosurgery, Department of Surgery, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| | - Antônio Carlos Dos Santos
- Division of Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| | - Daniel Giansante Abud
- Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirao Preto, São Paulo, Brazil
| |
Collapse
|
13
|
de Castro-Afonso LH, Nakiri GS, Abud TG, Monsignore LM, de Freitas RK, Abud DG. Aspirin monotherapy in the treatment of distal intracranial aneurysms with a surface modified flow diverter: a pilot study. J Neurointerv Surg 2021; 13:336-341. [PMID: 33514613 DOI: 10.1136/neurintsurg-2020-017024] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 12/15/2020] [Accepted: 12/23/2020] [Indexed: 12/14/2022]
Abstract
BACKGROUND Flow diverters (FDs) result in high occlusion rates of aneurysms located distally to the carotid artery. However, the complications reported are not negligible. New modified surface FDs have low thrombogenic properties that may reduce ischemic complications related to the treatment. In addition, a modified surface FD may allow for the use of a single antiplatelet medication to reduce hemorrhagic risk during the procedure. The aim of this study was to assess the safety and efficacy of the p48 MW HPC (phenox, Bochum, Germany) to treat distal intracranial aneurysms under the use of aspirin monotherapy. METHODS The primary endpoint was the incidence of any neurologic deficit after treatment after 6 months of follow-up. The secondary endpoint was the rate of the complete occlusion of the aneurysms at the 6-month follow-up. Enrollment of 20 patients was planned, but after inclusion of seven patients the study was stopped due to safety issues. RESULTS Seven patients with eight aneurysms were included. Among the seven patients, three (42.8%) had ischemic complications on the second day after FD deployment. Two patients experienced complete recovery at discharge (National Institutes of Health Stroke Scale (NIHSS) score=0), while one patient maintained mild dysarthria at discharge (NIHSS score=1) which improved after 6 months (NIHSS score=0). All three patients had no new symptoms during the 6-month follow-up. Complete aneurysm occlusion occurred in six (75%) of the eight aneurysms at the 6-month follow-up. CONCLUSIONS Antiplatelet monotherapy with aspirin for the treatment of distal intracranial aneurysms with this modified surface FD resulted in a significant incidence of ischemic complications after treatment.
Collapse
Affiliation(s)
- Luis Henrique de Castro-Afonso
- 1Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Universidade de Sao Paulo Faculdade de Medicina de Ribeirao Preto, Ribeirao Preto, São Paulo, Brazil
| | - Guilherme Seizem Nakiri
- 1Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Universidade de Sao Paulo Faculdade de Medicina de Ribeirao Preto, Ribeirao Preto, São Paulo, Brazil
| | - Thiago Giansante Abud
- 1Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Universidade de Sao Paulo Faculdade de Medicina de Ribeirao Preto, Ribeirao Preto, São Paulo, Brazil.,Interventional Neuroradiology, Hospital Israelita Albert Einstein, Sao Paulo, Brazil
| | - Lucas Moretti Monsignore
- 1Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Universidade de Sao Paulo Faculdade de Medicina de Ribeirao Preto, Ribeirao Preto, São Paulo, Brazil
| | - Rafael Kiyuze de Freitas
- 1Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Universidade de Sao Paulo Faculdade de Medicina de Ribeirao Preto, Ribeirao Preto, São Paulo, Brazil
| | - Daniel Giansante Abud
- 1Division of Interventional Neuroradiology, Department of Medical Imaging, Hematology and Oncology, Universidade de Sao Paulo Faculdade de Medicina de Ribeirao Preto, Ribeirao Preto, São Paulo, Brazil
| |
Collapse
|