1
|
Maqsood HA, Jawed HA, Kumar H, Bansal R, Shahid B, Nazir A, Rustam Z, Aized MT, Scemesky EA, Lepidi S, Bertoglio L, D'Oria M. Advanced Imaging Techniques for Complex Endovascular Aortic Repair: Preoperative, Intraoperative and Postoperative Advancements. Ann Vasc Surg 2024; 108:519-556. [PMID: 38942370 DOI: 10.1016/j.avsg.2024.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 06/02/2024] [Accepted: 06/07/2024] [Indexed: 06/30/2024]
Abstract
BACKGROUND Endovascular aortic repair (EVAR) requires extensive preoperative, intraoperative, and postoperative imaging for planning, surveillance, and detection of endo-leaks. There have been manyadvancements in imaging modalities to achieve this purpose. This review discussed different imaging modalities used at different stages of treatment of complex EVAR. METHODS We conducted a literature review of all the imaging modalities utilized in EVAR by searching various databases. RESULTS Preoperative techniques include analysis of images obtained via modified central line using analysis software and intravascular ultrasound. Fusion imaging (FI), carbon dioxide (CO2) angiography, intravascular ultrasound, and Fiber Optic RealShape (FORS) technology have been crucial in obtaining real-time imaging for the detection of endo-leaks during operative procedures. Conventional imaging modalities like computed tomography (CT) angiography (CTA) and magnetic resonance (MR) angiography are still employed for postoperative surveillance along with computational fluid dynamics and contrast-enhanced ultrasound (CEUS). The advancements in artificial intelligence (AI) have been the breakthrough in developing robust imaging applications. CONCLUSIONS This review explains the advantages, disadvantages, and side-effect profile of the abovementioned imaging modalities.
Collapse
Affiliation(s)
| | | | | | - Radha Bansal
- Government Medical College and Hospital, Chandigarh, India
| | | | | | - Zainab Rustam
- Wilmer Eye Institute, John Hopkins Medicine, Baltimore, MD, USA
| | - Majid Toseef Aized
- Ascension St. Mary's Hospital, Vascular Health Clinics, Saginaw, MI, USA
| | | | - Sandro Lepidi
- Division of Vascular and Endovascular Surgery, University Hospital of Trieste ASUGI, Trieste, Italy
| | - Luca Bertoglio
- Department of Vascular Surgery, Brescia University School of Medicine, Brescia, Italy
| | - Mario D'Oria
- Division of Vascular and Endovascular Surgery, University Hospital of Trieste ASUGI, Trieste, Italy
| |
Collapse
|
2
|
Sieren MM, Jäckle S, Eixmann T, Schulz-Hildebrandt H, Matysiak F, Preuss M, García-Vázquez V, Stahlberg E, Kleemann M, Barkhausen J, Goltz J, Horn M. Radiation-free Thoracic Endovascular Aneurysm Repair with Fiberoptic and Electromagnetic Guidance:A Phantom Study. J Vasc Interv Radiol 2021; 33:384-391.e7. [PMID: 34958860 DOI: 10.1016/j.jvir.2021.12.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 12/14/2021] [Accepted: 12/15/2021] [Indexed: 10/19/2022] Open
Abstract
PURPOSE The purpose of this study was to evaluate the feasibility and accuracy of a radiation-free implantation of a thoracic aortic stent-graft employing fiberoptic and electromagnetic tracking in an anthropomorphic phantom. MATERIALS AND METHODS An anthropomorphic phantom was manufactured based on computed tomography angiography (CTA) data from a patient. An aortic stent-graft application system was equipped with a fiber Bragg gratings fiber and three electromagnetic sensors. The stent-graft was navigated in the phantom by three interventionalists using the tracking data generated by both technologies. One implantation procedure was performed. The technical success of the procedure was evaluated using digital subtraction angiography and pre- and post-interventional CTA. Tracking accuracy was determined at various anatomical landmarks based on separately acquired fluoroscopic images. The mean/maximum errors were measured for the stent-graft application system and the tip/end of the stent-graft. RESULTS The procedure resulted in technical success with a mean error below 3 mm for the entire application system and <2 mm for the position of the tip of the stent-graft. Navigation/implantation and handling of the device were rated sufficiently accurate and on a par with comparable, routinely used stent-graft application systems. CONCLUSION Our study demonstrates successful stent-graft implantation during a thoracic endovascular aortic repair procedure employing advanced guidance techniques and avoiding fluoroscopic imaging. This is an essential step in facilitating the implantation of stent-grafts and reducing the health risks associated with ionizing radiation during endovascular procedures.
Collapse
Affiliation(s)
- Malte Maria Sieren
- Department of Radiology and Nuclear Medicine, University Hospital of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany.
| | - Sonja Jäckle
- Fraunhofer Institute for Digital Medicine MEVIS, Maria-Goeppert Straße 2, 23562 Lübeck, Germany
| | - Tim Eixmann
- Medical Laser Center Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| | | | - Florian Matysiak
- Department of Vascular Surgery, University Hospital of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Mark Preuss
- Department of Vascular Surgery, University Hospital of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Verónica García-Vázquez
- Institute for Robotics and Cognitive Systems, University of Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany, Lübeck, Germany
| | - Erik Stahlberg
- Department of Radiology and Nuclear Medicine, University Hospital of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Markus Kleemann
- Department of Vascular Surgery, University Hospital of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Jörg Barkhausen
- Department of Radiology and Nuclear Medicine, University Hospital of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Jan Goltz
- Department of Radiology and Neuroradiology, Sana Hospital, Kronsforder Allee 71-73, 23560 Lübeck, Germany
| | - Marco Horn
- Department of Vascular Surgery, University Hospital of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| |
Collapse
|