1
|
Mauri T, Grieco DL, Spinelli E, Leali M, Perez J, Chiavieri V, Rosà T, Ferrara P, Scaramuzzo G, Antonelli M, Spadaro S, Grasselli G. Personalized positive end-expiratory pressure in spontaneously breathing patients with acute respiratory distress syndrome by simultaneous electrical impedance tomography and transpulmonary pressure monitoring: a randomized crossover trial. Intensive Care Med 2024; 50:2125-2137. [PMID: 39527121 PMCID: PMC11588931 DOI: 10.1007/s00134-024-07695-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2024] [Accepted: 10/15/2024] [Indexed: 11/16/2024]
Abstract
PURPOSE Personalized positive end-expiratory pressure (PEEP) might foster lung and diaphragm protection in patients with acute respiratory distress syndrome (ARDS) who are undergoing pressure support ventilation (PSV). We aimed to compare the physiologic effects of personalized PEEP set according to synchronized electrical impedance tomography (EIT) and driving transpulmonary pressure (∆PL) monitoring against a classical lower PEEP/FiO2 table in intubated ARDS patients undergoing PSV. METHODS A cross-over randomized multicenter study was conducted in 30 ARDS patients with simultaneous recording of the airway, esophageal and transpulmonary pressure, together with EIT during PSV. Following a decremental PEEP trial (18 cmH2O to 4 cmH2O), PEEPEIT-∆PL was identified as the level with the smallest difference between lung overdistension and collapse. A low PEEP/FiO2 table was used to select PEEPTABLE. Each PEEP strategy was applied for 20 min, and physiologic data were collected at the end of each step. RESULTS The PEEP trial was well tolerated. Median PEEPEIT-∆PL was higher than PEEPTABLE (10 [8-12] vs. 8 [5-10] cmH2O; P = 0.021) and, at the individual patient level, PEEPEIT-∆PL level differed from PEEPTABLE in all patients. Overall, PEEPEIT-∆PL was associated with lower dynamic ∆PL (P < 0.001) and pressure-time product (P < 0.001), but there was variability among patients. PEEPEIT-∆PL also decreased respiratory drive and effort (P < 0.001), improved regional lung mechanics (P < 0.05) and reversed lung collapse (P = 0.007) without increasing overdistension (P = 0.695). CONCLUSION Personalized PEEP selected using synchronized EIT and transpulmonary pressure monitoring could be associated with reduced dynamic lung stress and metabolic work of breathing in ARDS patients undergoing PSV.
Collapse
Affiliation(s)
- Tommaso Mauri
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
- Department of Anesthesia, Critical Care and Emergency, Foundation IRCCS Ca' Granda Maggiore Policlinico Hospital, Milan, Italy.
| | - Domenico L Grieco
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Rome, Italy
| | - Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Foundation IRCCS Ca' Granda Maggiore Policlinico Hospital, Milan, Italy
| | - Marco Leali
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Joaquin Perez
- Department of Physical Therapy and Rehabilitation, Anchorena San Martín Clinic, Buenos Aires, Argentina
- Department of Emergency Medicine, Carlos G. Durand Hospital, Buenos Aires, Argentina
| | - Valentina Chiavieri
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Tommaso Rosà
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Rome, Italy
| | - Pierluigi Ferrara
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
- Department of Morphology, Surgery and Experimental Medicine, Intensive Care Unit, Sant'Anna University Hospital, Ferrara, Italy
| | - Gaetano Scaramuzzo
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
| | - Massimo Antonelli
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Rome, Italy
| | - Savino Spadaro
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
- Department of Morphology, Surgery and Experimental Medicine, Intensive Care Unit, Sant'Anna University Hospital, Ferrara, Italy
| | - Giacomo Grasselli
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
- Department of Anesthesia, Critical Care and Emergency, Foundation IRCCS Ca' Granda Maggiore Policlinico Hospital, Milan, Italy
| |
Collapse
|
2
|
Scaramuzzo G, Pavlovsky B, Adler A, Baccinelli W, Bodor DL, Damiani LF, Franchineau G, Francovich J, Frerichs I, Giralt JAS, Grychtol B, He H, Katira BH, Koopman AA, Leonhardt S, Menga LS, Mousa A, Pellegrini M, Piraino T, Priani P, Somhorst P, Spinelli E, Händel C, Suárez-Sipmann F, Wisse JJ, Becher T, Jonkman AH. Electrical impedance tomography monitoring in adult ICU patients: state-of-the-art, recommendations for standardized acquisition, processing, and clinical use, and future directions. Crit Care 2024; 28:377. [PMID: 39563476 PMCID: PMC11577873 DOI: 10.1186/s13054-024-05173-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2024] [Accepted: 11/13/2024] [Indexed: 11/21/2024] Open
Abstract
Electrical impedance tomography (EIT) is an emerging technology for the non-invasive monitoring of regional distribution of ventilation and perfusion, offering real-time and continuous data that can greatly enhance our understanding and management of various respiratory conditions and lung perfusion. Its application may be especially beneficial for critically ill mechanically ventilated patients. Despite its potential, clear evidence of clinical benefits is still lacking, in part due to a lack of standardization and transparent reporting, which is essential for ensuring reproducible research and enhancing the use of EIT for personalized mechanical ventilation. This report is the result of a four-day expert meeting where we aimed to promote the consistent and reliable use of EIT, facilitating its integration into both clinical practice and research, focusing on the adult intensive care patient. We discuss the state-of-the-art regarding EIT acquisition and processing, applications during controlled ventilation and spontaneous breathing, ventilation-perfusion assessment, and novel future directions.
Collapse
Affiliation(s)
- Gaetano Scaramuzzo
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
| | - Bertrand Pavlovsky
- Medical Intensive Care Unit, Vent'Lab, Angers University Hospital, University of Angers, 4 Rue Larrey, 49933, Angers Cedex 9, France
| | - Andy Adler
- Systems and Computer Engineering, Carleton University, Ottawa, Canada
| | | | - Dani L Bodor
- Netherlands eScience Center, Amsterdam, The Netherlands
| | - L Felipe Damiani
- Facultad de Medicina, Escuela de Ciencias de La Salud, Pontificia Universidad Catolica de Chile, Santiago, Chile
| | - Guillaume Franchineau
- Service de Medecine Intensive Reanimation, Centre Hospitalier Intercommunal de Poissy-Saint-Germain-en-Laye, Poissy, France
| | - Juliette Francovich
- Department of Intensive Care Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | | | | | - Huaiwu He
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Bhushan H Katira
- Department of Pediatrics, Washington University, St. Louis, MO, USA
| | - Alette A Koopman
- Division of Paediatric Critical Care Medicine, Department of Paediatrics, Beatrix Children's Hospital, University Medical Center Groningen, Groningen, The Netherlands
| | - Steffen Leonhardt
- Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany
| | - Luca S Menga
- Interdepartmental Division of Critical Care Medicine, Keenan Research Centre, Li Ka Shing Knowledge Institute, St. Michael's Hospital, University of Toronto, Toronto, Canada
| | - Amne Mousa
- Department of Intensive Care Medicine, Amsterdam UMC, Amsterdam, The Netherlands
| | - Mariangela Pellegrini
- Hedenstierna Laboratory, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Thomas Piraino
- Department of Anesthesia, Division of Critical Care, McMaster University, Hamilton, ON, Canada
| | - Paolo Priani
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
| | - Peter Somhorst
- Department of Intensive Care Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122, Milan, Italy
| | - Claas Händel
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Fernando Suárez-Sipmann
- Intensive Care Unit, Hospital Universitario La Princesa, Madrid, Spain
- CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain
| | - Jantine J Wisse
- Department of Intensive Care Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Tobias Becher
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Annemijn H Jonkman
- Department of Intensive Care Medicine, Erasmus Medical Center, Rotterdam, The Netherlands.
- Dept. Intensive Care Volwassenen, Erasmus Medical Center, Room Ne-403, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
| |
Collapse
|
3
|
Petitjeans F, Longrois D, Ghignone M, Quintin L. Combining O 2 High Flow Nasal or Non-Invasive Ventilation with Cooperative Sedation to Avoid Intubation in Early Diffuse Severe Respiratory Distress Syndrome, Especially in Immunocompromised or COVID Patients? J Crit Care Med (Targu Mures) 2024; 10:291-315. [PMID: 39916864 PMCID: PMC11799322 DOI: 10.2478/jccm-2024-0035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 08/01/2024] [Indexed: 02/09/2025] Open
Abstract
This overview addresses the pathophysiology of the acute respiratory distress syndrome (ARDS; conventional vs. COVID), the use of oxygen high flow (HFN) vs. noninvasive ventilation (NIV; conventional vs. helmet) and a multi-modal approach to avoid endotracheal intubation ("intubation"): low normal temperature, cooperative sedation, normalized systemic and microcirculation, anti-inflammation, reduced lung water, upright position, lowered intra-abdominal pressure. Increased ventilatory muscle activity ("respiratory drive") is observed in early ARDS, at variance with ventilatory fatigue observed in decompensated chronic obstructive pulmonary disease (COPD). This increased drive leads to impending then overt ventilatory failure. Therefore, muscle relaxation presents little rationale and should be replaced by lowering the excessive respiratory drive, increased work of breathing, continued or increased labored breathing, self-induced lung injury (SILI), i.e. preserving spontaneous breathing. As CMV is a lifesaver in the setting of failure but does not heal the lung, side-effects of intubation, controlled mechanical ventilation (CMV), paralysis and deep sedation are to be avoided. Additionally, critical care resources shortage requires practice changes. Therefore, NIV should be routine when addressing immune-compromised patients. The SARS-CoV2 pandemics extended this approach to most patients, which are immune-compromised: elderly, obese, diabetic, etc. The early COVID is a pulmonary vascular endothelial inflammatory disease requiring lower positive-end-expiratory pressure than the typical pulmonary alveolar epithelial inflammatory diffuse ARDS. This leads one to reassess a) the technique of NIV b) the sedation regimen facilitating continuous and extended NIV to avoid intubation. Autonomic, circulatory, respiratory, ventilatory physiology is hierarchized under HFN/NIV and cooperative sedation (dexmedetomidine, clonidine). A prospective randomized pilot trial, then a larger trial are required to ascertain our working hypotheses.
Collapse
Affiliation(s)
- Fabrice Petitjeans
- Department of Anesthesia-Critical Care, Hôpital d’Instruction des Armées Desgenettes, Lyon, France
| | - Dan Longrois
- Bichat-Claude Bernard and Louis Mourier Hospitals, Assistance Publique-Hôpitaux de Paris, Paris Cité University, Paris, France
| | - Marco Ghignone
- Department of Anesthesia-Critical Care, JF Kennedy North Hospital, W Palm Beach, Fl, USA
| | - Luc Quintin
- Department of Anesthesia-Critical Care, Hôpital d’Instruction des Armées Desgenettes, Lyon, France
| |
Collapse
|
4
|
Spontaneous Breathing and Pendelluft in Patients with Acute Lung Injury: A Narrative Review. J Clin Med 2022; 11:jcm11247449. [PMID: 36556064 PMCID: PMC9783194 DOI: 10.3390/jcm11247449] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 12/10/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
Acute respiratory distress syndrome (ARDS) is characterized by acute-onset rapid-deteriorating inflammatory lung injury. Although the preservation of spontaneous breathing may have physiological benefits in oxygenation, increasing evidence shows that vigorous spontaneous breathing may aggravate lung injury (i.e., patient self-inflicted lung injury). Increased lung stress and pendelluft, which is defined as intrapulmonary gas redistribution without a significant change in tidal volume, are important mechanisms of patient self-inflicted lung injury. The presence of pendelluft may be considered a surrogate marker of vigorous inspiratory effort, which can cause the dependent lung to overstretch. In this review, we summarized three major methods for electrical impedance tomography-based pendelluft monitoring. Future studies are warranted to compare and validate the different methods of pendelluft estimation in patients with ARDS.
Collapse
|
5
|
Dos Santos Rocha A, Südy R, Bizzotto D, Kassai M, Carvalho T, Dellacà RL, Peták F, Habre W. Benefit of Physiologically Variable Over Pressure-Controlled Ventilation in a Model of Chronic Obstructive Pulmonary Disease: A Randomized Study. Front Physiol 2021; 11:625777. [PMID: 33519528 PMCID: PMC7839245 DOI: 10.3389/fphys.2020.625777] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 12/15/2020] [Indexed: 11/25/2022] Open
Abstract
Introduction The advantages of physiologically variable ventilation (PVV) based on a spontaneous breathing pattern have been demonstrated in several respiratory conditions. However, its potential benefits in chronic obstructive pulmonary disease (COPD) have not yet been characterized. We used an experimental model of COPD to compare respiratory function outcomes after 6 h of PVV versus conventional pressure-controlled ventilation (PCV). Materials and Methods Rabbits received nebulized elastase and lipopolysaccharide throughout 4 weeks. After 30 days, animals were anesthetized, tracheotomized, and randomized to receive 6 h of physiologically variable (n = 8) or conventional PCV (n = 7). Blood gases, respiratory mechanics, and chest fluoroscopy were assessed hourly. Results After 6 h of ventilation, animals receiving variable ventilation demonstrated significantly higher oxygenation index (PaO2/FiO2 441 ± 37 (mean ± standard deviation) versus 354 ± 61 mmHg, p < 0.001) and lower respiratory elastance (359 ± 36 versus 463 ± 81 cmH2O/L, p < 0.01) than animals receiving PCV. Animals ventilated with the variable mode also presented less lung derecruitment (decrease in lung aerated area, –3.4 ± 9.9 versus –17.9 ± 6.7%, p < 0.01) and intrapulmonary shunt fraction (9.6 ± 4.1 versus 17.0 ± 5.8%, p < 0.01). Conclusion PVV applied to a model of COPD improved oxygenation, respiratory mechanics, lung aeration, and intrapulmonary shunt fraction compared to conventional ventilation. A reduction in alveolar derecruitment and lung tissue stress leading to better aeration and gas exchange may explain the benefits of PVV.
Collapse
Affiliation(s)
- Andre Dos Santos Rocha
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| | - Roberta Südy
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| | - Davide Bizzotto
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Miklos Kassai
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| | - Tania Carvalho
- Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Lisbon, Portugal
| | - Raffaele L Dellacà
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Ferenc Peták
- Department of Medical Physics and Informatics, Faculty of Medicine, University of Szeged, Szeged, Hungary
| | - Walid Habre
- Unit for Anaesthesiological Investigations, Department of Acute Medicine, University Hospitals of Geneva, University of Geneva, Geneva, Switzerland
| |
Collapse
|
6
|
Çankaya BY, Polat G, Tezcan A, Yalçın A, Sade R, Pirimoğlu RB, Karaman A, Kızıloğlu HA, Alper F, Akgün M. Evaluation of lung densitometric and volumetric changes in silicosis patients using three-dimensional software for multidetector CT and the relationship with profusion scores. Clin Radiol 2021; 76:393.e19-393.e24. [PMID: 33509607 DOI: 10.1016/j.crad.2020.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 12/24/2020] [Indexed: 11/25/2022]
Abstract
AIM To evaluate the density and volume changes in the lungs of silicosis patients and their relationship with the disease severity classification of the International Labor Organization (ILO). MATERIALS AND METHODS The multidetector computed tomography (CT) images of 44 patients diagnosed with silicosis and 32 controls that underwent thoracic CT due to trauma were evaluated. Patients with silicosis were divided into three categories according to the ILO classification. Data related to the total lung volume, total lung mean density, lung opacity score, percentage of lung high opacity, and mean density in the lower and upper lobes were obtained using three-dimensional (3D) software. RESULTS There was no significant difference between the total lung mean densities of the silicosis and control groups (p=0.213); however, a significant difference was observed between the two groups in terms of the total lung volume (p<0.0001). According to the ILO classification, there was a significant difference between the disease severity categories in relation to the percentage of lung high opacity (p=0.000005). A strong correlation was detected between disease severity and high opacity percentage (p<0.0001, r=0.804). According to the ILO classification, there was also a significant difference between disease severity categories in terms of the lung opacity score (p=0.000144), as well as a moderate correlation between disease severity and opacity score (p<0.0001, r=0.580). CONCLUSION Total lung volume is a CT finding that shows variation in exposure to crystalline silica. The percentage of high opacity determined using multidetector CT is an effective parameter in evaluating disease severity.
Collapse
Affiliation(s)
- B Y Çankaya
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey.
| | - G Polat
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| | - A Tezcan
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| | - A Yalçın
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| | - R Sade
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| | - R B Pirimoğlu
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| | - A Karaman
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| | - H A Kızıloğlu
- Ömer Halisdemir Training and Research Hospital, Niğde, Turkey
| | - F Alper
- Department of Radiology, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| | - M Akgün
- Department of Pulmonary Diseases, Atatürk University School of Medicine, Atatürk University, 25240, Erzurum, Turkey
| |
Collapse
|
7
|
Faria ACD, Carvalho ARS, Guimarães ARM, Lopes AJ, Melo PL. Association of respiratory integer and fractional-order models with structural abnormalities in silicosis. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 172:53-63. [PMID: 30902127 DOI: 10.1016/j.cmpb.2019.02.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 01/23/2019] [Accepted: 02/06/2019] [Indexed: 06/09/2023]
Abstract
BACKGROUND AND OBJECTIVE Integer and fractional-order models have emerged as powerful methods for obtaining information regarding the anatomical or pathophysiological changes that occur during respiratory diseases. However, the precise interpretation of the model parameters in light of the lung structural changes is not known. This study analyzed the associations of the integer and fractional-order models with structural changes obtained using multidetector computed tomography densitometry (MDCT) and pulmonary function analysis. METHODS Integer and fractional-order models were adjusted to data obtained using the forced oscillation technique (FOT). The results obtained in controls (n = 20) were compared with those obtained in patients with silicosis (n = 32), who were submitted to spirometry, body plethysmograph, FOT, diffusing capacity of the lungs for carbon monoxide (DLCO), and MDCT. The diagnostic accuracy was also investigated using ROC analysis. RESULTS The observed changes in the integer and fractional-order models were consistent with the pathophysiology of silicosis. The integer-order model showed association only between inertance and the non-aerated compartment (R = -0.69). This parameter also presented the highest associations with spirometry (R = 0.81), plethysmography (-0.61) and pulmonary diffusion (R = 0.53). Considering the fractional-order model, the increase in the poorly aerated and non-aerated regions presented direct correlations with the fractional inertance (R = 0.48), respiratory damping (R = 0.37) and hysteresivity (R = 0.54) and inverse associations with its fractional exponent (R = -0.62) and elastance (-0.35). Significant associations were also observed with spirometry (R = 0.63), plethysmography (0.37) and pulmonary diffusion (R = 0.51). Receiver operator characteristic analysis showed a higher accuracy in the FrOr model (0.908) than the eRIC model (0.789). CONCLUSIONS Our study has shown clear associations of the integer and fractional-order parameters with anatomical changes obtained via MDCT and pulmonary function measurements. These findings help to elucidate the physiological interpretation of the integer and fractional-order parameters and provide evidence that these parameters are reflective of the abnormal changes in silicosis. We also observed that the fractional-order model showed smaller curve-fitting errors, which resulted in a higher diagnostic accuracy than that of the eRIC model. Taken together, these results provide strong motivation for further studies exploring the clinical and scientific use of these models in respiratory medicine.
Collapse
Affiliation(s)
- Alvaro C D Faria
- Biomedical Instrumentation Laboratory, Institute of Biology Roberto Alcantara Gomes, State University of Rio de Janeiro, Rio de Janeiro, Brazil; Laboratory of Clinical and Experimental Research in Vascular Biology (BioVasc), State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Alysson Roncally Silva Carvalho
- Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; Laboratory of Pulmonary Engineering, Biomedical Engineering Program, Alberto Luis Coimbra Institute of Postgraduation and Research in Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Alan Ranieri Medeiros Guimarães
- Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; Laboratory of Pulmonary Engineering, Biomedical Engineering Program, Alberto Luis Coimbra Institute of Postgraduation and Research in Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Agnaldo J Lopes
- Pulmonary Function Laboratory, Pedro Ernesto University Hospital, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Pedro L Melo
- Biomedical Instrumentation Laboratory, Institute of Biology Roberto Alcantara Gomes, State University of Rio de Janeiro, Rio de Janeiro, Brazil; Laboratory of Clinical and Experimental Research in Vascular Biology (BioVasc), State University of Rio de Janeiro, Rio de Janeiro, Brazil.
| |
Collapse
|
8
|
Toufen Junior C, De Santis Santiago RR, Hirota AS, Carvalho ARS, Gomes S, Amato MBP, Carvalho CRR. Driving pressure and long-term outcomes in moderate/severe acute respiratory distress syndrome. Ann Intensive Care 2018; 8:119. [PMID: 30535520 PMCID: PMC6286297 DOI: 10.1186/s13613-018-0469-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2018] [Accepted: 12/03/2018] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Acute respiratory distress syndrome (ARDS) patients may present impaired in lung function and structure after hospital discharge that may be related to mechanical ventilation strategy. The aim of this study was to evaluate the association between functional and structural lung impairment, N-terminal-peptide type III procollagen (NT-PCP-III) and driving pressure during protective mechanical ventilation. It was a secondary analysis of data from randomized controlled trial that included patients with moderate/severe ARDS with at least one follow-up visit performed. We obtained serial measurements of plasma NT-PCP-III levels. Whole-lung computed tomography analysis and pulmonary function test were performed at 1 and 6 months of follow-up. A health-related quality of life survey after 6 months was also performed. RESULTS Thirty-three patients were enrolled, and 21 patients survived after 6 months. In extubation day an association between driving pressure and NT-PCP-III was observed. At 1 and 6 months forced vital capacity (FVC) was negatively correlated to driving pressure (p < 0.01). At 6 months driving pressure was associated with lower FVC independently on tidal volume, plateau pressure and baseline static respiratory compliance after adjustments (r2 = 0.51, p = 0.02). There was a significant correlation between driving pressure and lung densities and nonaerated/poorly aerated lung volume after 6 months. Driving pressure was also related to general health domain of SF-36 at 6 months. CONCLUSION Even in patients ventilated with protective tidal volume, higher driving pressure is associated with worse long-term pulmonary function and structure.
Collapse
Affiliation(s)
- Carlos Toufen Junior
- Divisão de Pneumologia, Cardiopulmonary Department, Heart Institute (InCor) University of São Paulo, INCOR Av. Dr. Enéas de Carvalho Aguiar, 44 Pinheiros, São Paulo, SP, CEP 05403-900, Brazil.
| | - Roberta R De Santis Santiago
- Divisão de Pneumologia, Cardiopulmonary Department, Heart Institute (InCor) University of São Paulo, INCOR Av. Dr. Enéas de Carvalho Aguiar, 44 Pinheiros, São Paulo, SP, CEP 05403-900, Brazil
| | - Adriana S Hirota
- Divisão de Pneumologia, Cardiopulmonary Department, Heart Institute (InCor) University of São Paulo, INCOR Av. Dr. Enéas de Carvalho Aguiar, 44 Pinheiros, São Paulo, SP, CEP 05403-900, Brazil
| | - Alysson Roncally S Carvalho
- Laboratory of Pulmonary Engineering, Biomedical Engineering Program, Alberto Luiz Coimbra Institute of Post-Graduation and Research in Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.,Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Susimeire Gomes
- Divisão de Pneumologia, Cardiopulmonary Department, Heart Institute (InCor) University of São Paulo, INCOR Av. Dr. Enéas de Carvalho Aguiar, 44 Pinheiros, São Paulo, SP, CEP 05403-900, Brazil
| | - Marcelo Brito Passos Amato
- Respiratory Intensive Care Unit, University of São Paulo School of Medicine Hospital das Clínicas, São Paulo, Brazil
| | - Carlos Roberto Ribeiro Carvalho
- Divisão de Pneumologia, Cardiopulmonary Department, Heart Institute (InCor) University of São Paulo, INCOR Av. Dr. Enéas de Carvalho Aguiar, 44 Pinheiros, São Paulo, SP, CEP 05403-900, Brazil
| |
Collapse
|
9
|
Santos CL, Santos RS, Moraes L, Samary CS, Felix NS, Silva JD, Morales MM, Huhle R, Abreu MG, Schanaider A, Silva PL, Pelosi P, Rocco PRM. Effects of pressure support and pressure-controlled ventilation on lung damage in a model of mild extrapulmonary acute lung injury with intra-abdominal hypertension. PLoS One 2017; 12:e0178207. [PMID: 28542443 PMCID: PMC5444773 DOI: 10.1371/journal.pone.0178207] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Accepted: 05/08/2017] [Indexed: 12/22/2022] Open
Abstract
Intra-abdominal hypertension (IAH) may co-occur with the acute respiratory distress syndrome (ARDS), with significant impact on morbidity and mortality. Lung-protective controlled mechanical ventilation with low tidal volume and positive end-expiratory pressure (PEEP) has been recommended in ARDS. However, mechanical ventilation with spontaneous breathing activity may be beneficial to lung function and reduce lung damage in mild ARDS. We hypothesized that preserving spontaneous breathing activity during pressure support ventilation (PSV) would improve respiratory function and minimize ventilator-induced lung injury (VILI) compared to pressure-controlled ventilation (PCV) in mild extrapulmonary acute lung injury (ALI) with IAH. Thirty Wistar rats (334±55g) received Escherichia coli lipopolysaccharide intraperitoneally (1000μg) to induce mild extrapulmonary ALI. After 24h, animals were anesthetized and randomized to receive PCV or PSV. They were then further randomized into subgroups without or with IAH (15 mmHg) and ventilated with PCV or PSV (PEEP = 5cmH2O, driving pressure adjusted to achieve tidal volume = 6mL/kg) for 1h. Six of the 30 rats were used for molecular biology analysis and were not mechanically ventilated. The main outcome was the effect of PCV versus PSV on mRNA expression of interleukin (IL)-6 in lung tissue. Regardless of whether IAH was present, PSV resulted in lower mean airway pressure (with no differences in peak airway or peak and mean transpulmonary pressures) and less mRNA expression of biomarkers associated with lung inflammation (IL-6) and fibrogenesis (type III procollagen) than PCV. In the presence of IAH, PSV improved oxygenation; decreased alveolar collapse, interstitial edema, and diffuse alveolar damage; and increased expression of surfactant protein B as compared to PCV. In this experimental model of mild extrapulmonary ALI associated with IAH, PSV compared to PCV improved lung function and morphology and reduced type 2 epithelial cell damage.
Collapse
Affiliation(s)
- Cintia L. Santos
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
- Laboratory of Experimental Surgery, Faculty of Medicine, Federal University of Rio de Janeiro, Av. Professor Rodolpho Paulo Rocco, 225, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Raquel S. Santos
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Lillian Moraes
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Cynthia S. Samary
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Nathane S. Felix
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Johnatas D. Silva
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Marcelo M. Morales
- Laboratory of Cellular and Molecular Physiology, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G2-048, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Robert Huhle
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Dresden University of Technology, Fetschertsrasse 74, Dresden, Germany
| | - Marcelo G. Abreu
- Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Dresden University of Technology, Fetschertsrasse 74, Dresden, Germany
| | - Alberto Schanaider
- Laboratory of Experimental Surgery, Faculty of Medicine, Federal University of Rio de Janeiro, Av. Professor Rodolpho Paulo Rocco, 225, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Pedro L. Silva
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| | - Paolo Pelosi
- IRCCS AOU San Martino-IST, Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, Largo Rosanna Benzi 8, Genoa, Italy
| | - Patricia R. M. Rocco
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av. Carlos Chagas Filho, s/n, Bloco G-014, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
| |
Collapse
|
10
|
Abstract
Controlled Mechanical Ventilation may be essential in the setting of severe respiratory failure but consequences to the patient including increased use of sedation and neuromuscular blockade may contribute to delirium, atelectasis, and diaphragm dysfunction. Assisted ventilation allows spontaneous breathing activity to restore physiological displacement of the diaphragm and recruit better perfused lung regions. Pressure Support Ventilation is the most frequently used mode of assisted mechanical ventilation. However, this mode continues to provide a monotonous pattern of support for respiration which is normally a dynamic process. Noisy Pressure Support Ventilation where tidal volume is varied randomly by the ventilator may improve ventilation and perfusion matching but the degree of support is still determined by the ventilator. Two more recent modes of ventilation, Proportional Assist Ventilation and Neurally Adjusted Ventilatory Assist (NAVA), allow patient determination of the pattern and depth of ventilation. Proposed advantages of Proportional Assist Ventilation and NAVA include decrease in patient ventilator asynchrony and improved adaptation of ventilator support to changing patient demand. Work of breathing can be normalized with these modes as well. To date, however, a clear pattern of clinical benefit has not been demonstrated. Existing challenges for both of the newer assist modes include monitoring patients with dynamic hyperinflation (auto-positive end expiratory pressure), obstructive lung disease, and air leaks in the ventilator system. NAVA is dependent on consistent transduction of diaphragm activity by an electrode system placed in the esophagus. Longevity of effective support with this technique is unclear.
Collapse
|
11
|
Jain SV, Kollisch-Singule M, Sadowitz B, Dombert L, Satalin J, Andrews P, Gatto LA, Nieman GF, Habashi NM. The 30-year evolution of airway pressure release ventilation (APRV). Intensive Care Med Exp 2016; 4:11. [PMID: 27207149 PMCID: PMC4875584 DOI: 10.1186/s40635-016-0085-2] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Accepted: 05/03/2016] [Indexed: 02/07/2023] Open
Abstract
Airway pressure release ventilation (APRV) was first described in 1987 and defined as continuous positive airway pressure (CPAP) with a brief release while allowing the patient to spontaneously breathe throughout the respiratory cycle. The current understanding of the optimal strategy to minimize ventilator-induced lung injury is to "open the lung and keep it open". APRV should be ideal for this strategy with the prolonged CPAP duration recruiting the lung and the minimal release duration preventing lung collapse. However, APRV is inconsistently defined with significant variation in the settings used in experimental studies and in clinical practice. The goal of this review was to analyze the published literature and determine APRV efficacy as a lung-protective strategy. We reviewed all original articles in which the authors stated that APRV was used. The primary analysis was to correlate APRV settings with physiologic and clinical outcomes. Results showed that there was tremendous variation in settings that were all defined as APRV, particularly CPAP and release phase duration and the parameters used to guide these settings. Thus, it was impossible to assess efficacy of a single strategy since almost none of the APRV settings were identical. Therefore, we divided all APRV studies divided into two basic categories: (1) fixed-setting APRV (F-APRV) in which the release phase is set and left constant; and (2) personalized-APRV (P-APRV) in which the release phase is set based on changes in lung mechanics using the slope of the expiratory flow curve. Results showed that in no study was there a statistically significant worse outcome with APRV, regardless of the settings (F-ARPV or P-APRV). Multiple studies demonstrated that P-APRV stabilizes alveoli and reduces the incidence of acute respiratory distress syndrome (ARDS) in clinically relevant animal models and in trauma patients. In conclusion, over the 30 years since the mode's inception there have been no strict criteria in defining a mechanical breath as being APRV. P-APRV has shown great promise as a highly lung-protective ventilation strategy.
Collapse
Affiliation(s)
- Sumeet V Jain
- Department of Surgery, SUNY Upstate Medical University, 750 E Adams St, Syracuse, NY, 13210, USA
| | | | - Benjamin Sadowitz
- Department of Surgery, SUNY Upstate Medical University, 750 E Adams St, Syracuse, NY, 13210, USA
| | - Luke Dombert
- Department of Surgery, SUNY Upstate Medical University, 750 E Adams St, Syracuse, NY, 13210, USA
| | - Josh Satalin
- Department of Surgery, SUNY Upstate Medical University, 750 E Adams St, Syracuse, NY, 13210, USA.
| | - Penny Andrews
- Multi-trauma Critical Care, R Adams Cowley Shock Trauma Center, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD, USA
| | - Louis A Gatto
- Department of Surgery, SUNY Upstate Medical University, 750 E Adams St, Syracuse, NY, 13210, USA.,Department of Biological Sciences, 10 SUNY Cortland, Cortland, NY, 13045, USA
| | - Gary F Nieman
- Department of Surgery, SUNY Upstate Medical University, 750 E Adams St, Syracuse, NY, 13210, USA
| | - Nader M Habashi
- Multi-trauma Critical Care, R Adams Cowley Shock Trauma Center, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD, USA
| |
Collapse
|
12
|
Abdominal Muscle Activity during Mechanical Ventilation Increases Lung Injury in Severe Acute Respiratory Distress Syndrome. PLoS One 2016; 11:e0145694. [PMID: 26745868 PMCID: PMC4712828 DOI: 10.1371/journal.pone.0145694] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2015] [Accepted: 12/06/2015] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE It has proved that muscle paralysis was more protective for injured lung in severe acute respiratory distress syndrome (ARDS), but the precise mechanism is not clear. The purpose of this study was to test the hypothesis that abdominal muscle activity during mechanically ventilation increases lung injury in severe ARDS. METHODS Eighteen male Beagles were studied under mechanical ventilation with anesthesia. Severe ARDS was induced by repetitive oleic acid infusion. After lung injury, Beagles were randomly assigned into spontaneous breathing group (BIPAPSB) and abdominal muscle paralysis group (BIPAPAP). All groups were ventilated with BIPAP model for 8h, and the high pressure titrated to reached a tidal volume of 6ml/kg, the low pressure was set at 10 cmH2O, with I:E ratio 1:1, and respiratory rate adjusted to a PaCO2 of 35-60 mmHg. Six Beagles without ventilator support comprised the control group. Respiratory variables, end-expiratory volume (EELV) and gas exchange were assessed during mechanical ventilation. The levels of Interleukin (IL)-6, IL-8 in lung tissue and plasma were measured by qRT-PCR and ELISA respectively. Lung injury scores were determined at end of the experiment. RESULTS For the comparable ventilator setting, as compared with BIPAPSB group, the BIPAPAP group presented higher EELV (427±47 vs. 366±38 ml) and oxygenation index (293±36 vs. 226±31 mmHg), lower levels of IL-6(216.6±48.0 vs. 297.5±71.2 pg/ml) and IL-8(246.8±78.2 vs. 357.5±69.3 pg/ml) in plasma, and lower express levels of IL-6 mRNA (15.0±3.8 vs. 21.2±3.7) and IL-8 mRNA (18.9±6.8 vs. 29.5±7.9) in lung tissues. In addition, less lung histopathology injury were revealed in the BIPAPAP group (22.5±2.0 vs. 25.2±2.1). CONCLUSION Abdominal muscle activity during mechanically ventilation is one of the injurious factors in severe ARDS, so abdominal muscle paralysis might be an effective strategy to minimize ventilator-induce lung injury.
Collapse
|
13
|
Camilo GB, Carvalho ARS, Machado DC, Mogami R, Melo PL, Lopes AJ. CT pulmonary densitovolumetry in patients with acromegaly: a comparison between active disease and controlled disease. Br J Radiol 2015; 88:20150315. [PMID: 26246281 DOI: 10.1259/bjr.20150315] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE Our purpose was to compare the findings of CT pulmonary densitovolumetry and pulmonary function in patients with active acromegaly and controlled acromegaly and, secondarily, to correlate these findings. METHODS 11 patients with active acromegaly, 18 patients with controlled acromegaly and 17 control subjects, all non-smokers, underwent quantification of lung volume using multidetector CT (Q-MDCT) and pulmonary function tests. RESULTS Patients with active acromegaly had larger total lung mass (TLM) values than the controls and larger amounts of non-aerated compartments than the other two groups. Patients with active acromegaly also had larger amounts of poorly aerated compartments than the other two groups, a difference that was observed in both total lung volume (TLV) and TLM. TLV as measured by inspiratory Q-MDCT correlated significantly with total lung capacity, whereas TLV measured using expiratory Q-MDCT correlated significantly with functional residual capacity. CONCLUSION Patients with active acromegaly have more lung mass and larger amounts of non-aerated and poorly aerated compartments. There is a relationship between the findings of CT pulmonary densitovolumetry and pulmonary function test parameters. ADVANCES IN KNOWLEDGE Although the nature of our results demands further investigation, our data suggest that both CT pulmonary densitovolumetry and pulmonary function tests can be used as useful tools for patients with acromegaly by assisting in the prediction of disease activity.
Collapse
Affiliation(s)
- Gustavo B Camilo
- 1 Post-graduate Programme in Medical Sciences, School of Medical Sciences, State University of Rio de Janeiro, Rio de Janeiro, Brazil.,2 Department of Radiology, State University of Rio de Janeiro, Rio de Janeiro, Brazil.,3 State Institute of Brain Paulo Niemeyer, Rio de Janeiro, Brazil.,4 Faculty of Medical and Health Sciences of Juiz de Fora (SUPREMA), Juiz de Fora, Brazil
| | - Alysson R S Carvalho
- 5 Laboratory of Respiration Physiology, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.,6 Laboratory of Pulmonary Engineering, Biomedical Engineering Program, Alberto Luiz Coimbra Institute of Post-Graduation and Research in Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Dequitier C Machado
- 1 Post-graduate Programme in Medical Sciences, School of Medical Sciences, State University of Rio de Janeiro, Rio de Janeiro, Brazil.,2 Department of Radiology, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Roberto Mogami
- 1 Post-graduate Programme in Medical Sciences, School of Medical Sciences, State University of Rio de Janeiro, Rio de Janeiro, Brazil.,2 Department of Radiology, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Pedro L Melo
- 7 Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Rio de Janeiro, Brazil.,8 Post-graduate Program in Clinical and Experimental Physiopathology (FISCLINEX), School of Medical Sciences, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Agnaldo J Lopes
- 1 Post-graduate Programme in Medical Sciences, School of Medical Sciences, State University of Rio de Janeiro, Rio de Janeiro, Brazil.,9 Laboratory of Pulmonary Function, University of the State of Rio de Janeiro, Rio de Janeiro, Brazil
| |
Collapse
|
14
|
Camilo GB, Carvalho ARS, Machado DC, Mogami R, Kasuki L, Gadelha MR, Melo PL, Lopes AJ. Correlations between forced oscillation technique parameters and pulmonary densitovolumetry values in patients with acromegaly. ACTA ACUST UNITED AC 2015; 48:877-85. [PMID: 26445330 PMCID: PMC4617113 DOI: 10.1590/1414-431x20154786] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Accepted: 04/29/2015] [Indexed: 01/17/2023]
Abstract
The aims of this study were to evaluate the forced oscillation technique (FOT) and
pulmonary densitovolumetry in acromegalic patients and to examine the correlations
between these findings. In this cross-sectional study, 29 non-smoking acromegalic
patients and 17 paired controls were subjected to the FOT and quantification of lung
volume using multidetector computed tomography (Q-MDCT). Compared with the controls,
the acromegalic patients had a higher value for resonance frequency [15.3 (10.9-19.7)
vs 11.4 (9.05-17.6) Hz, P=0.023] and a lower value for mean
reactance [0.32 (0.21-0.64) vs 0.49 (0.34-0.96) cm
H2O/L/s2, P=0.005]. In inspiratory Q-MDCT, the acromegalic
patients had higher percentages of total lung volume (TLV) for nonaerated and poorly
aerated areas [0.42% (0.30-0.51%) vs 0.25% (0.20-0.32%), P=0.039 and
3.25% (2.48-3.46%) vs 1.70% (1.45-2.15%), P=0.001, respectively].
Furthermore, the acromegalic patients had higher values for total lung mass in both
inspiratory and expiratory Q-MDCT [821 (635-923) vs 696 (599-769) g,
P=0.021 and 844 (650-945) vs 637 (536-736) g, P=0.009,
respectively]. In inspiratory Q-MDCT, TLV showed significant correlations with all
FOT parameters. The TLV of hyperaerated areas showed significant correlations with
intercept resistance (rs=−0.602, P<0.001) and mean resistance
(rs=−0.580, P<0.001). These data showed that acromegalic patients
have increased amounts of lung tissue as well as nonaerated and poorly aerated areas.
Functionally, there was a loss of homogeneity of the respiratory system. Moreover,
there were correlations between the structural and functional findings of the
respiratory system, consistent with the pathophysiology of the disease.
Collapse
Affiliation(s)
- G B Camilo
- Programa de Pós-Graduação em Ciências Médicas, Faculdade de Ciências Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, BR
| | - A R S Carvalho
- Laboratório de Fisiologia da Respiração, Instituto de Biofísica Carlos Chagas Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, BR
| | - D C Machado
- Programa de Pós-Graduação em Ciências Médicas, Faculdade de Ciências Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, BR
| | - R Mogami
- Programa de Pós-Graduação em Ciências Médicas, Faculdade de Ciências Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, BR
| | - L Kasuki
- Instituto Estadual do Cérebro Paulo Niemeyer, Rio de Janeiro, RJ, BR
| | - M R Gadelha
- Instituto Estadual do Cérebro Paulo Niemeyer, Rio de Janeiro, RJ, BR
| | - P L Melo
- Programa de Pós-Graduação em Ciências Médicas, Faculdade de Ciências Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, BR
| | - A J Lopes
- Programa de Pós-Graduação em Ciências Médicas, Faculdade de Ciências Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, BR
| |
Collapse
|
15
|
Lopes AJ, Mogami R, Camilo GB, Machado DC, Melo PL, Carvalho ARS. Relationships between the pulmonary densitometry values obtained by CT and the forced oscillation technique parameters in patients with silicosis. Br J Radiol 2015; 88:20150028. [PMID: 25747897 DOI: 10.1259/bjr.20150028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To evaluate the correlations between pulmonary densitometry values and forced oscillation technique (FOT) parameters in patients with silicosis. METHODS This cross-sectional study comprised 36 non-smoker patients with silicosis and 20 matched control subjects who were submitted to FOT and multidetector CT (MDCT). RESULTS Compared with the control subjects, the MDCT evaluation demonstrated that patients with silicosis exhibited greater total lung mass. These patients also had larger non-aerated and poorly aerated compartments, which included nodules and scarring. Compared with the control subjects, FOT evaluation demonstrated that patients with silicosis exhibited changes in both reactive and resistive properties of the respiratory system. In these patients, there was a greater heterogeneity of the respiratory system and increased work of breathing. Significant correlations between non-aerated compartment size and FOT parameters that reflect the non-homogeneity of the respiratory system were observed. The dynamic compliance of the respiratory system was negatively correlated with non-aerated compartment size, while the impedance at 4 Hz was positively correlated with non-aerated compartment size. CONCLUSION Patients with silicosis have heavier lungs. In these patients, a larger non-aerated compartment is associated with a worsening of lung function. A more significant pulmonary involvement is associated with a loss of homogeneity and increased mechanical load of the respiratory system. Advances in knowledge The findings provided by both pulmonary densitometry and FOT may add valuable information to the subjective analysis of silicosis; however, more studies are necessary to evaluate the potential use of these methods for assessing disease progression.
Collapse
Affiliation(s)
- A J Lopes
- 1 Postgraduate Programme in Medical Sciences, State University of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | | | | | | | | |
Collapse
|
16
|
Di Marco F, Bonacina D, Vassena E, Arisi E, Apostolo A, Banfi C, Centanni S, Agostoni P, Fumagalli R. The Effects of Anesthesia, Muscle Paralysis, and Ventilation on the Lung Evaluated by Lung Diffusion for Carbon Monoxide and Pulmonary Surfactant Protein B. Anesth Analg 2015; 120:373-80. [DOI: 10.1213/ane.0000000000000496] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
17
|
Higher levels of spontaneous breathing reduce lung injury in experimental moderate acute respiratory distress syndrome. Crit Care Med 2014; 42:e702-15. [PMID: 25162475 DOI: 10.1097/ccm.0000000000000605] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To assess the effects of different levels of spontaneous breathing during biphasic positive airway pressure/airway pressure release ventilation on lung function and injury in an experimental model of moderate acute respiratory distress syndrome. DESIGN Multiple-arm randomized experimental study. SETTING University hospital research facility. SUBJECTS Thirty-six juvenile pigs. INTERVENTIONS Pigs were anesthetized, intubated, and mechanically ventilated. Moderate acute respiratory distress syndrome was induced by repetitive saline lung lavage. Biphasic positive airway pressure/airway pressure release ventilation was conducted using the airway pressure release ventilation mode with an inspiratory/expiratory ratio of 1:1. Animals were randomly assigned to one of four levels of spontaneous breath in total minute ventilation (n = 9 per group, 6 hr each): 1) biphasic positive airway pressure/airway pressure release ventilation, 0%; 2) biphasic positive airway pressure/airway pressure release ventilation, > 0-30%; 3) biphasic positive airway pressure/airway pressure release ventilation, > 30-60%, and 4) biphasic positive airway pressure/airway pressure release ventilation, > 60%. MEASUREMENTS AND MAIN RESULTS The inspiratory effort measured by the esophageal pressure time product increased proportionally to the amount of spontaneous breath and was accompanied by improvements in oxygenation and respiratory system elastance. Compared with biphasic positive airway pressure/airway pressure release ventilation of 0%, biphasic positive airway pressure/airway pressure release ventilation more than 60% resulted in lowest venous admixture, as well as peak and mean airway and transpulmonary pressures, redistributed ventilation to dependent lung regions, reduced the cumulative diffuse alveolar damage score across lungs (median [interquartile range], 11 [3-40] vs 18 [2-69]; p < 0.05), and decreased the level of tumor necrosis factor-α in ventral lung tissue (median [interquartile range], 17.7 pg/mg [8.4-19.8] vs 34.5 pg/mg [29.9-42.7]; p < 0.05). Biphasic positive airway pressure/airway pressure release ventilation more than 0-30% and more than 30-60% showed a less consistent pattern of improvement in lung function, inflammation, and damage compared with biphasic positive airway pressure/airway pressure release ventilation more than 60%. CONCLUSIONS In this model of moderate acute respiratory distress syndrome in pigs, biphasic positive airway pressure/airway pressure release ventilation with levels of spontaneous breath higher than usually seen in clinical practice, that is, more than 30% of total minute ventilation, reduced lung injury with improved respiratory function, as compared with protective controlled mechanical ventilation.
Collapse
|
18
|
Sutherasan Y, D'Antini D, Pelosi P. Advances in ventilator-associated lung injury: prevention is the target. Expert Rev Respir Med 2014; 8:233-48. [PMID: 24601663 DOI: 10.1586/17476348.2014.890519] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Mechanical ventilation (MV) is the main supportive treatment in respiratory failure due to different etiologies. However, MV might aggravate ventilator-associated lung injury (VALI). Four main mechanisms leading to VALI are: 1) increased stress and strain, induced by high tidal volume (VT); 2) increased shear stress, i.e. opening and closing, of previously atelectatic alveolar units; 3) distribution of perfusion and 4) biotrauma. In severe acute respiratory distress syndrome patients, low VT, higher levels of positive end expiratory pressure, long duration prone position and neuromuscular blockade within the first 48 hours are associated to a better outcome. VALI can also occur by using high VT in previously non injured lungs. We believe that prevention is the target to minimize injurious effects of MV. This review aims to describe pathophysiology of VALI, the possible prevention and treatment as well as monitoring MV to minimize VALI.
Collapse
Affiliation(s)
- Yuda Sutherasan
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, IRCCS San Martino - IST, Genoa, Italy
| | | | | |
Collapse
|
19
|
Ziebart A, Hartmann EK, Thomas R, Liu T, Duenges B, Schad A, Bodenstein M, Thal SC, David M. Low tidal volume pressure support versus controlled ventilation in early experimental sepsis in pigs. Respir Res 2014; 15:101. [PMID: 25189285 PMCID: PMC4172867 DOI: 10.1186/s12931-014-0101-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Accepted: 08/18/2014] [Indexed: 11/30/2022] Open
Abstract
Background In moderate acute respiratory distress syndrome (ARDS) several studies support the usage of assisted spontaneous breathing modes. Only limited data, however, focus on the application in systemic sepsis and developing lung injury. The present study examines the effects of immediate initiation of pressure support ventilation (PSV) in a model of sepsis-induced ARDS. Methods 18 anesthetized pigs received a two-staged continuous lipopolysaccharide infusion to induce lung injury. The animals were randomly assigned to PSV or volume controlled (VCV) lung protective ventilation (tidal volume each 6 ml kg-1, n = 2x9) over six hours. Gas exchange parameters, hemodynamics, systemic inflammation, and ventilation distribution by multiple inert gas elimination and electrical impedance tomography were assessed. The post mortem analysis included histopathological scoring, wet to dry ratio, and alveolar protein content. Results Within six hours both groups developed a mild to moderate ARDS with comparable systemic inflammatory response and without signs of improving gas exchange parameters during PSV. The PSV group showed signs of more homogenous ventilation distribution by electrical impedance tomography, but only slightly less hyperinflated lung compartments by multiple inert gas elimination. Post mortem and histopathological assessment yielded no significant intergroup differences. Conclusions In a porcine model of sepsis-induced mild ARDS immediate PSV was not superior to VCV. This contrasts with several experimental studies from non-septic mild to moderate ARDS. The present study therefore assumes that not only severity, but also etiology of lung injury considerably influences the response to early initiation of PSV.
Collapse
|
20
|
Higher levels of spontaneous breathing induce lung recruitment and reduce global stress/strain in experimental lung injury. Anesthesiology 2014; 120:673-82. [PMID: 24406799 DOI: 10.1097/aln.0000000000000124] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Spontaneous breathing (SB) in the early phase of the acute respiratory distress syndrome is controversial. Biphasic positive airway pressure/airway pressure release ventilation (BIPAP/APRV) is commonly used, but the level of SB necessary to maximize potential beneficial effects is unknown. METHODS Experimental acute respiratory distress syndrome was induced by saline lung lavage in anesthetized and mechanically ventilated pigs (n = 12). By using a Latin square and crossover design, animals were ventilated with BIPAP/APRV at four different levels of SB in total minute ventilation (60 min each): (1) 0% (BIPAP/APRV0%); (2) greater than 0 to 30% (BIPAP/APRV>0-30%); (3) greater than 30 to 60% (BIPAP/APRV>30-60%); and (4) greater than 60% (BIPAP/APRV>60%). Gas exchange, hemodynamics, and respiratory variables were measured. Lung aeration was assessed by high-resolution computed tomography. The distribution of perfusion was marked with Ga-labeled microspheres and evaluated by positron emission tomography. RESULTS The authors found that higher levels of SB during BIPAP/APRV (1) improved oxygenation; (2) decreased mean transpulmonary pressure (stress) despite increased inspiratory effort; (3) reduced nonaerated lung tissue, with minimal changes in the distribution of perfusion, resulting in decreased low aeration/perfusion zones; and (4) decreased global strain (mean ± SD) (BIPAP/APRV0%: 1.39 ± 0.08; BIPAP/APRV0-30%: 1.33 ± 0.03; BIPAP/APRV30-60%: 1.27 ± 0.06; BIPAP/APRV>60%: 1.25 ± 0.04, P < 0.05 all vs. BIPAP/APRV0%, and BIPAP/APRV>60% vs. BIPAP/APRV0-30%). CONCLUSIONS In a saline lung lavage model of experimental acute respiratory distress syndrome in pigs, levels of SB during BIPAP/APRV higher than currently recommended for clinical practice, that is, 10 to 30%, improve oxygenation by increasing aeration in dependent lung zones without relevant redistribution of perfusion. In presence of lung recruitment, higher levels of SB reduce global stress and strain despite an increase in inspiratory effort.
Collapse
|
21
|
Prospective randomized crossover study of a new closed-loop control system versus pressure support during weaning from mechanical ventilation. Anesthesiology 2013; 119:631-41. [PMID: 23619172 DOI: 10.1097/aln.0b013e3182952608] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Intellivent is a new full closed-loop controlled ventilation that automatically adjusts both ventilation and oxygenation parameters. The authors compared gas exchange and breathing pattern variability of Intellivent and pressure support ventilation (PSV). METHODS In a prospective, randomized, single-blind design crossover study, 14 patients were ventilated during the weaning phase, with Intellivent or PSV, for two periods of 24 h in a randomized order. Arterial blood gases were obtained after 1, 8, 16, and 24 h with each mode. Ventilatory parameters were recorded continuously in a breath-by-breath basis during the two study periods. The primary endpoint was oxygenation, estimated by the calculation of the difference between the PaO2/FIO2 ratio obtained after 24 h of ventilation and the PaO2/FIO2 ratio obtained at baseline in each mode. The variability in the ventilatory parameters was also evaluated by the coefficient of variation (SD to mean ratio). RESULTS There were no adverse events or safety issues requiring premature interruption of both modes. The PaO2/FIO2 (mean ± SD) ratio improved significantly from 245 ± 75 at baseline to 294 ± 123 (P = 0.03) after 24 h of Intellivent. The coefficient of variation of inspiratory pressure and positive end-expiratory pressure (median [interquartile range]) were significantly higher with Intellivent, 16 [11-21] and 15 [7-23]%, compared with 6 [5-7] and 7 [5-10]% in PSV. Inspiratory pressure, positive end-expiratory pressure, and FIO2 changes were adjusted significantly more often with Intellivent compared with PSV. CONCLUSIONS Compared with PSV, Intellivent during a 24-h period improved the PaO2/FIO2 ratio in parallel with more variability in the ventilatory support and more changes in ventilation settings.
Collapse
|
22
|
Prospective crossover comparison between NAVA and pressure control ventilation in premature neonates less than 1500 grams. J Perinatol 2013; 33:452-6. [PMID: 23100042 DOI: 10.1038/jp.2012.136] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
OBJECTIVE Neurally adjusted ventilatory assist (NAVA) synchronizes spontaneous respiratory effort with mechanical ventilation. Electrodes detect the electrical activity of the diaphragm (Edi) and transmit this information to the ventilator, allowing the patient to determine their own respiratory rate (RR), peak pressures, and inspiratory and expiratory times in synchrony with the ventilator. The objective of this study was to evaluate if premature neonates ventilate as effectively on NAVA as compared to pressure control ventilation (PCV). STUDY DESIGN Five ventilated neonates were enrolled (gestational age 25-29 weeks). Each neonate was ventilated on NAVA for 4 h, then switched to PCV for another 4 h. The cycle was repeated three times. Ventilatory parameters were averaged every 30 min to collect eight time points for each ventilatory mode. Data were analyzed using the mixed effects model procedure, utilizing the least-squares means (P<0.05). RESULT When compared to PCV, neonates ventilated with NAVA had lower peak inspiratory pressures (PIP), fraction of inspired oxygen (FiO2), transcutaneous PCO2 Edi peak and RR. There was an increase in expiratory tidal volume (TV), compliance and Edi minimum. Despite lower PIP and RR, partial pressure of CO2 (PCO2) was lower when ventilated on NAVA. There was no difference in mean airway pressure. CONCLUSION Premature neonates ventilated with NAVA required less PIP, FiO2 and RR to achieve lower PCO2 and better compliance compared with PCV.
Collapse
|
23
|
Pulmonary Shunt Is Independent of Decrease in Cardiac Output during Unsupported Spontaneous Breathing in the Pig. Anesthesiology 2013; 118:914-23. [DOI: 10.1097/aln.0b013e318283c81f] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Abstract
Background:
During mechanical ventilation (MV), pulmonary shunt is cardiac output (CO) dependent; however, whether this relationship is valid during unsupported spontaneous breathing (SB) is unknown. The CO dependency of the calculated venous admixture was investigated, with both minor and major shunt, during unsupported SB, MV, and SB with continuous positive airway pressure (CPAP).
Methods:
In seven anesthetized supine piglets breathing 100% oxygen, unsupported SB, MV (with tidal volume and respiratory rate corresponding to SB), and 8 cm H2O CPAP (airway pressure corresponding to MV) were applied at random. Venous return and CO were reduced by partial balloon occlusion of the inferior vena cava. Measurements were repeated with the left main bronchus blocked, creating a nonrecruitable pulmonary shunt.
Results:
CO decreased from 4.2 l/min (95% CI, 3.9–4.5) to 2.5 l/min (95% CI, 2.2–2.7) with partially occluded venous return. Irrespective of whether shunt was minor or major, during unsupported SB, venous admixture was independent of CO (slope: minor shunt, 0.5; major shunt, 1.1%·min−1·l−1) and mixed venous oxygen tension. During both MV and CPAP, venous admixture was dependent on CO (slope MV: minor shunt, 1.9; major shunt, 3.5; CPAP: minor shunt, 1.3; major shunt, 2.9%·min−1·l−1) and mixed-venous oxygen tension (coefficient of determination 0.61–0.86 for all regressions).
Conclusions:
In contrast to MV and CPAP, venous admixture was independent of CO during unsupported SB, and was unaffected by mixed-venous oxygen tension, casting doubt on the role of hypoxic pulmonary vasoconstriction in pulmonary blood flow redistribution during unsupported SB.
Collapse
|
24
|
McMullen SM, Meade M, Rose L, Burns K, Mehta S, Doyle R, Henzler D, for the Canadian Critical Care Trials Group (CCCTG). Partial ventilatory support modalities in acute lung injury and acute respiratory distress syndrome-a systematic review. PLoS One 2012; 7:e40190. [PMID: 22916094 PMCID: PMC3420868 DOI: 10.1371/journal.pone.0040190] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2012] [Accepted: 06/02/2012] [Indexed: 01/21/2023] Open
Abstract
PURPOSE The efficacy of partial ventilatory support modes that allow spontaneous breathing in patients with acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) is unclear. The objective of this scoping review was to assess the effects of partial ventilatory support on mortality, duration of mechanical ventilation, and both hospital and intensive care unit (ICU) lengths of stay (LOS) for patients with ALI and ARDS; the secondary objective was to describe physiologic effects on hemodynamics, respiratory system and other organ function. METHODS MEDLINE (1966-2009), Cochrane, and EmBase (1980-2009) databases were searched using common ventilator modes as keywords and reference lists from retrieved manuscripts hand searched for additional studies. Two researchers independently reviewed and graded the studies using a modified Oxford Centre for Evidence-Based Medicine grading system. Studies in adult ALI/ARDS patients were included for primary objectives and pre-clinical studies for supporting evidence. RESULTS Two randomized controlled trials (RCTs) were identified, in addition to six prospective cohort studies, one retrospective cohort study, one case control study, 41 clinical physiologic studies and 28 pre-clinical studies. No study was powered to assess mortality, one RCT showed shorter ICU length of stay, and the other demonstrated more ventilator free days. Beneficial effects of preserved spontaneous breathing were mainly physiological effects demonstrated as improvement of gas exchange, hemodynamics and non-pulmonary organ perfusion and function. CONCLUSIONS The use of partial ventilatory support modalities is often feasible in patients with ALI/ARDS, and may be associated with short-term physiological benefits without appreciable impact on clinically important outcomes.
Collapse
Affiliation(s)
- Sarah M. McMullen
- Department of Anesthesiology and Critical Care Medicine, Dalhousie University, Halifax, Canada
| | - Maureen Meade
- Departments of Medicine and Clinical Epidemiology & Biostatistics, McMaster University, Hamilton, Canada
| | - Louise Rose
- Lawrence S. Bloomberg Faculty of Nursing, University of Toronto, Toronto, Canada
| | - Karen Burns
- Interdepartmental Division of Critical Care, University of Toronto and St Michael's Hospital, and Li Ka Shing Knowledge Institute, Toronto, Canada
| | - Sangeeta Mehta
- Department of Medicine and Interdepartmental Division of Critical Care Medicine, Mount Sinai Hospital, University of Toronto, Toronto, Canada
| | - Robert Doyle
- Department of Anesthesiology and Critical Care Medicine, Dalhousie University, Halifax, Canada
| | - Dietrich Henzler
- Department of Anesthesiology and Critical Care Medicine, Dalhousie University, Halifax, Canada
| | | |
Collapse
|
25
|
Spontaneous breathing activity in acute lung injury and acute respiratory distress syndrome. Curr Opin Anaesthesiol 2012; 25:148-55. [DOI: 10.1097/aco.0b013e3283504bde] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
26
|
Abstract
PURPOSE OF REVIEW New developments in mechanical ventilation have focused on increasing the patient's control of the ventilator by implementing information on lung mechanics and respiratory drive. Effort-adapted modes of assisted breathing are presented and their potential advantages are discussed. RECENT FINDINGS Adaptive support ventilation, proportional assist ventilation with load adjustable gain factors and neurally adjusted ventilatory assist are ventilatory modes that follow the concept of adapting the assist to a defined target, instantaneous changes in respiratory drive or lung mechanics. Improved patient ventilator interaction, sufficient unloading of the respiratory muscles and increased comfort have been recently associated with these ventilator modalities. There are, however, scarce data with regard to outcome improvement, such as length of mechanical ventilation, ICU stay or mortality (commonly accepted targets to demonstrate clinical superiority). SUMMARY Within recent years, a major step forward in the evolution of assisted (effort-adapted) modes of mechanical ventilation was accomplished. There is growing evidence that supports the physiological concept of closed-loop effort-adapted assisted modes of mechanical ventilation. However, at present, the translation into a clear outcome benefit remains to be proven. In order to fill the knowledge gap that impedes the broader application, larger randomized controlled trials are urgently needed. However, with clearly proven drawbacks of conventional assisted modes such as pressure support ventilation, it is probably about time to leave these modes introduced decades ago behind.
Collapse
|
27
|
Vimlati L, Larsson A, Hedenstierna G, Lichtwarck-Aschoff M. During spontaneous breathing cardiac output lacks major effect on pulmonary shunting in porcine lungs with partial collapse. Crit Care 2012. [PMCID: PMC3363538 DOI: 10.1186/cc10727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
|
28
|
Vimlati L, Kawati R, Hedenstierna G, Larsson A, Lichtwarck-Aschoff M. Spontaneous breathing improves shunt fraction and oxygenation in comparison with controlled ventilation at a similar amount of lung collapse. Anesth Analg 2011; 113:1089-95. [PMID: 21918161 DOI: 10.1213/ane.0b013e31822ceef8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Spontaneous breathing (SB), when allowed during mechanical ventilation (MV), improves oxygenation in different models of acute lung injury. However, it is not known whether oxygenation is improved during mechanically unsupported SB. Therefore, we compared SB without any support with controlled MV at identical tidal volume (VT) and respiratory rate (RR) without positive end-expiratory pressure in a porcine lung collapse model. METHODS In 25 anesthetized piglets, stable lung collapse was induced by application of negative pressure, and animals were randomized to either resume SB or to be kept on MV at identical VT (5 mL/kg; 95% confidence interval: 3.8 to 6.4) and RR (65 per minute [57 to 73]) as had been measured during an initial SB period. Oxygenation was assessed by blood gas analysis (n=15) completed by multiple inert gas elimination technique (n=8 of the 15) for shunt measurement. In addition, possible lung recruitment was studied with computed tomography of the chest (n=10). RESULTS After induction of lung collapse, PaO2/FIO2 decreased to 90 mm Hg (76 to 103). With SB, PaO2/FIO2 increased to 235 mm Hg (177 to 293) within 15 minutes, whereas MV at identical Vt and RR did not cause any improvement in oxygenation. Intrapulmonary shunt by 45 minutes after induction of lung collapse was lower during SB (SB: 27% [24 to 30] versus MV: 41% [28 to 55]; P=0.017). Neither SB nor MV reduced collapsed lung areas on computed tomography. CONCLUSIONS SB without any support improves oxygenation and reduces shunt in comparison with MV at identical settings. This seems to be achieved without any major signs of recruitment of collapsed lung regions.
Collapse
Affiliation(s)
- Laszlo Vimlati
- Department of Surgical Sciences, Anesthesiology and Critical Care Medicine, Uppsala University; S-751 85 Uppsala, Sweden.
| | | | | | | | | |
Collapse
|
29
|
Karcz M, Vitkus A, Papadakos PJ, Schwaiberger D, Lachmann B. State-of-the-art mechanical ventilation. J Cardiothorac Vasc Anesth 2011; 26:486-506. [PMID: 21601477 DOI: 10.1053/j.jvca.2011.03.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2010] [Indexed: 02/01/2023]
Affiliation(s)
- Marcin Karcz
- Department of Anesthesiology, University of Rochester, Rochester, NY 14642, USA.
| | | | | | | | | |
Collapse
|
30
|
Spontaneously regulated vs. controlled ventilation of acute lung injury/acute respiratory distress syndrome. Curr Opin Crit Care 2011; 17:24-9. [PMID: 21157317 DOI: 10.1097/mcc.0b013e328342726e] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE OF REVIEW To present an updated discussion of those aspects of controlled positive pressure breathing and retained spontaneous regulation of breathing that impact the management of patients whose tissue oxygenation is compromised by acute lung injury. RECENT FINDINGS The recent introduction of ventilation techniques geared toward integrating natural breathing rhythms into even the earliest phase of acute respiratory distress syndrome support (e.g., airway pressure release, proportional assist ventilation, and neurally adjusted ventilatory assist), has stimulated a burst of new investigations. SUMMARY Optimizing gas exchange, avoiding lung injury, and preserving respiratory muscle strength and endurance are vital therapeutic objectives for managing acute lung injury. Accordingly, comparing the physiology and consequences of breathing patterns that preserve and eliminate breathing effort has been a theme of persisting investigative interest throughout the several decades over which it has been possible to sustain cardiopulmonary life support outside the operating theater.
Collapse
|
31
|
Pressure support improves oxygenation and lung protection compared to pressure-controlled ventilation and is further improved by random variation of pressure support*. Crit Care Med 2011; 39:746-55. [DOI: 10.1097/ccm.0b013e318206bda6] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Carvalho AR, Spieth PM, Güldner A, Cuevas M, Carvalho NC, Beda A, Spieth S, Stroczynski C, Wiedemann B, Koch T, Pelosi P, de Abreu MG. Distribution of regional lung aeration and perfusion during conventional and noisy pressure support ventilation in experimental lung injury. J Appl Physiol (1985) 2011; 110:1083-92. [PMID: 21270348 DOI: 10.1152/japplphysiol.00804.2010] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
In acute lung injury (ALI), pressure support ventilation (PSV) may improve oxygenation compared with pressure-controlled ventilation (PCV), and benefit from random variation of pressure support (noisy PSV). We investigated the effects of PCV, PSV, and noisy PSV on gas exchange as well as the distribution of lung aeration and perfusion in 12 pigs with ALI induced by saline lung lavage in supine position. After injury, animals were mechanically ventilated with PCV, PSV, and noisy PSV for 1 h/mode in random sequence. The driving pressure was set to a mean tidal volume of 6 ml/kg and positive end-expiratory pressure to 8 cmH₂O in all modes. Functional variables were measured, and the distribution of lung aeration was determined by static and dynamic computed tomography (CT), whereas the distribution of pulmonary blood flow (PBF) was determined by intravenously administered fluorescent microspheres. PSV and noisy PSV improved oxygenation and reduced venous admixture compared with PCV. Mechanical ventilation with PSV and noisy PSV did not decrease nonaerated areas but led to a redistribution of PBF from dorsal to ventral lung regions and reduced tidal reaeration and hyperinflation compared with PCV. Noisy PSV further improved oxygenation and redistributed PBF from caudal to cranial lung regions compared with conventional PSV. We conclude that assisted ventilation with PSV and noisy PSV improves oxygenation compared with PCV through redistribution of PBF from dependent to nondependent zones without lung recruitment. Random variation of pressure support further redistributes PBF and improves oxygenation compared with conventional PSV.
Collapse
Affiliation(s)
- Alysson R Carvalho
- Clinic of Anesthesiology and Intensive Care Therapy, Univ. Hospital Dresden, Dresden, Germany
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
In vivo microscopy in a porcine model of acute lung injury. Respir Physiol Neurobiol 2010; 172:192-200. [DOI: 10.1016/j.resp.2010.05.021] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2010] [Revised: 05/05/2010] [Accepted: 05/27/2010] [Indexed: 11/22/2022]
|
34
|
Silva PL, Cruz FF, Fujisaki LC, Oliveira GP, Samary CS, Ornellas DS, Maron-Gutierrez T, Rocha NN, Goldenberg R, Garcia CSNB, Morales MM, Capelozzi VL, Gama de Abreu M, Pelosi P, Rocco PRM. Hypervolemia induces and potentiates lung damage after recruitment maneuver in a model of sepsis-induced acute lung injury. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2010; 14:R114. [PMID: 20546573 PMCID: PMC2911760 DOI: 10.1186/cc9063] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2010] [Revised: 04/21/2010] [Accepted: 06/14/2010] [Indexed: 01/02/2023]
Abstract
Introduction Recruitment maneuvers (RMs) seem to be more effective in extrapulmonary acute lung injury (ALI), caused mainly by sepsis, than in pulmonary ALI. Nevertheless, the maintenance of adequate volemic status is particularly challenging in sepsis. Since the interaction between volemic status and RMs is not well established, we investigated the effects of RMs on lung and distal organs in the presence of hypovolemia, normovolemia, and hypervolemia in a model of extrapulmonary lung injury induced by sepsis. Methods ALI was induced by cecal ligation and puncture surgery in 66 Wistar rats. After 48 h, animals were anesthetized, mechanically ventilated and randomly assigned to 3 volemic status (n = 22/group): 1) hypovolemia induced by blood drainage at mean arterial pressure (MAP)≈70 mmHg; 2) normovolemia (MAP≈100 mmHg), and 3) hypervolemia with colloid administration to achieve a MAP≈130 mmHg. In each group, animals were further randomized to be recruited (CPAP = 40 cm H2O for 40 s) or not (NR) (n = 11/group), followed by 1 h of protective mechanical ventilation. Echocardiography, arterial blood gases, static lung elastance (Est,L), histology (light and electron microscopy), lung wet-to-dry (W/D) ratio, interleukin (IL)-6, IL-1β, caspase-3, type III procollagen (PCIII), intercellular adhesion molecule-1 (ICAM-1), and vascular cell adhesion molecule-1 (VCAM-1) mRNA expressions in lung tissue, as well as lung and distal organ epithelial cell apoptosis were analyzed. Results We observed that: 1) hypervolemia increased lung W/D ratio with impairment of oxygenation and Est,L, and was associated with alveolar and endothelial cell damage and increased IL-6, VCAM-1, and ICAM-1 mRNA expressions; and 2) RM reduced alveolar collapse independent of volemic status. In hypervolemic animals, RM improved oxygenation above the levels observed with the use of positive-end expiratory pressure (PEEP), but increased lung injury and led to higher inflammatory and fibrogenetic responses. Conclusions Volemic status should be taken into account during RMs, since in this sepsis-induced ALI model hypervolemia promoted and potentiated lung injury compared to hypo- and normovolemia.
Collapse
Affiliation(s)
- Pedro L Silva
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Institute of Biophysics, Federal University of Rio de Janeiro, Av Carlos Chagas Filho, Rio de Janeiro 21949-902, Brazil.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|