1
|
Parrella A, Rusconi D, Povoli A, Guarini A, Munno N, Petrocelli G, Basile I, Rampichini F, Consolo L. Mapping training programs for endoscopy nurses in gastroenterology: a scoping review. Eur J Gastroenterol Hepatol 2025; 37:702-709. [PMID: 40207485 DOI: 10.1097/meg.0000000000002951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/11/2025]
Abstract
OBJECTIVE Given the significant differences in the scope of practice for endoscopy nurses across various countries and due to the heterogeneity in training required to become an endoscopy nurse, this study aims to map the existing training programs designed for endoscopy nurse in gastroenterology and examine the influence of such educational programs on clinical practice and patient care outcomes. METHODS A scoping review was conducted using the Arksey and O'Malley framework. We identified studies relevant to endoscopy nurse training across databases including PubMed, Embase, Web of Science, SCOPUS, and CINAHL. Eligible studies focused on training programs for endoscopy nurses and were subjected to a two-stage screening process. Data extraction focused on program characteristics, skill development, and clinical outcomes. RESULTS Of 4834 records, 12 studies were included in the final analysis. These studies detailed diverse training programs ranging from 1-day workshops to 2-year extensive programs. Key skills developed included sedation administration, airway management, handling endoscopy equipment, and interpreting capsule endoscopy images. Nontechnical skills, such as communication, teamwork, and crisis management, were also emphasized. Training programs demonstrated a positive impact on clinical and organizational outcomes, reducing adverse events and improving procedural efficiency. Endoscopy nurses also reported higher job satisfaction following training. CONCLUSION Training programs for endoscopy nurses play a vital role in improving both technical and nontechnical competencies, enhancing clinical practice and patient safety. However, significant variability exists in the content and duration of these programs. Standardizing training practices could further optimize nurse performance and patient outcomes in gastroenterology endoscopy.
Collapse
Affiliation(s)
- Arianna Parrella
- Gastroenterology and Digestive Endoscopy Unit, Azienda Unità Sanitaria Locale di Modena, Modena
| | - Daniele Rusconi
- Urologic Oncology Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan
| | - Arianna Povoli
- Gastroenterology Unit, Azienda Sanitaria Universitaria Friuli Centrale, Udine
| | - Alessandra Guarini
- Gastroenterology and Digestive Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome
| | - Nazario Munno
- DAPSS-RAD Surgical Department, Azienda Socio-Sanitaria Territoriale della Brianza, Vimercate
| | - Giulio Petrocelli
- DAPSS, Digestive and Interventional Endoscopy Unit, ASST Grande Ospedale Metropolitano Niguarda
| | - Ilaria Basile
- High-Complexity Unit of Palliative Care, Pain Therapy and Rehabilitation, Fondazione IRCCS Istituto Nazionale dei Tumori
| | | | - Letteria Consolo
- Bachelor School of Nursing, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy
| |
Collapse
|
2
|
González-Mendibil I, García-Pascual E, Villanueva A, García-Gutiérrez S. Bispectral index monitoring for sedation in scheduled adult colonoscopy: A randomized controlled trial. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2024; 71:633-644. [PMID: 38663652 DOI: 10.1016/j.redare.2024.04.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 11/02/2023] [Accepted: 12/06/2023] [Indexed: 05/01/2024]
Abstract
BACKGROUND Patients should be closely monitored during procedures under sedation outside the operating room, but it is unclear which type of monitoring is best. We investigated the efficacy and safety of BIS monitoring vs conventional monitoring for sedation during colonoscopy. METHODS We performed a double-blind clinical trial in 180 patients undergoing elective colonoscopy. Patients were randomized to 1) the BIS group or 2) a control group, in which sedation was monitored with a BIS monitor or the Ramsay Sedation Score, respectively. The primary outcome was the rate of sedation-induced adverse events in both groups. Secondary outcomes were the characteristics of patients who developed adverse events, and time during colonoscopy when these events occurred, propofol and remifentanil dosage, and patient satisfaction. RESULTS Univariate analysis showed fewer cardiopulmonary complications in the BIS group (41.11% vs 57.78% in controls; p = 0.02). Multivariate analysis found a significantly higher risk of adverse events in older patients (95% CI, 1.013-1.091; p = 0.0087) and in men (95% CI, 1.129-7.668; p = 0.0272). These events were observed at the hepatic flexure. No significant differences between propofol or remifentanil dosage, use of rescue medication, and patient satisfaction were observed between groups. CONCLUSIONS Our data suggest that BIS monitoring during sedation in scheduled colonoscopies reduces adverse respiratory events. Although its routine use in sedation does not appear to be warranted, clinicians should take steps to identify patients with a higher risk of complications who might benefit from this type of monitoring.
Collapse
Affiliation(s)
- I González-Mendibil
- Department of Anesthesiology, Galdakao University Hospital, Galdakao, Bizkaia, Spain.
| | - E García-Pascual
- Department of Anesthesiology, Galdakao University Hospital, Galdakao, Bizkaia, Spain
| | - A Villanueva
- Research Unit, Galdakao University Hospital, Galdakao, Bizkaia, Spain; Kronikgune Institute for Health Services Research, Barakaldo, Bizkaia, Spain
| | | |
Collapse
|
3
|
Bou Daher H, El Mokahal A, Ibrahim MA, Yamout R, Hochaimi N, Ayoub C, Shaib YH, Sharara AI. General anesthesia and/or deep hypnotic state in propofol-based conscious sedation for endoscopy. IGIE 2024; 3:286-292. [DOI: 10.1016/j.igie.2024.04.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2025]
|
4
|
Sachdeva A, Jaswal S, Walia HS, Batra YK. Correlating the Depth of Sedation Between the Ramsay Sedation Scale and Bispectral Index Using Either Intravenous Midazolam or Intravenous Propofol in Elderly Patients Under Spinal Anaesthesia. Cureus 2023; 15:e50763. [PMID: 38239522 PMCID: PMC10794813 DOI: 10.7759/cureus.50763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/18/2023] [Indexed: 01/22/2024] Open
Abstract
BACKGROUND Supplementation of spinal anaesthesia with sedatives or anxiolytics has emerged as a standard protocol to alleviate patients' anxiety and to produce amnesia during the surgical procedure. Thus, judicious use of sedation can make surgeries under spinal anaesthesia more comfortable and acceptable for the elderly patient, the surgeon, and the anaesthesiologist. However, over-sedation may jeopardise the safety of the patient. Appropriate sedation helps reduce physiological stress, which leads to a better result. Therefore, monitoring the depth of sedation becomes essential. The Ramsay sedation scale (RSS) and bispectral index (BIS) both are used widely to assess the depth of sedation. OBJECTIVES The primary objective of the study was to assess and correlate the depth of sedation between the BIS and RSS in elderly patients using midazolam and propofol under spinal anaesthesia. The secondary objectives were to observe any difference in the commencement of sedation between the two groups and to observe haemodynamic changes between the two groups. METHODS A total of 60 elderly patients undergoing urological procedures under spinal anaesthesia were randomly assigned to receive either midazolam (Group A, n=30) or propofol (Group B, n=30) for sedation. In Group A, patients were given an initial bolus of midazolam 0.03 mg/kg and a maintenance incremental bolus of 0.01 mg/kg up to a maximum of 2.5 mg in 10-minute intervals. Group B used propofol with an initial bolus dose of 0.5 mg/kg over two minutes and a maintenance bolus of 10-20 mg as required for the maintenance of sedation depth. Sedation was titrated to achieve a BIS score of 70-80 and an RSS score of 3-4. Heart rate, non-invasive systolic, diastolic, mean arterial blood pressure, oxygen saturation (SPO2), and the correlation coefficient between the BIS and RSS were measured at 0 (baseline), 5, 10, 20, 30, 40, 50, and 60 minutes of interval. RESULTS The correlation coefficient between the BIS and RSS scores in Group A at various time intervals indicate a strong correlation coefficient of -0.76 at five minutes, -0.64 at 20 minutes, -0.78 at 30 minutes, -0.56 at 40 minutes, and -0.39 at 50 minutes. In Group B, the correlation coefficient between the BIS and RSS scores at various time intervals indicate a strong correlation coefficient of -0.75 at five minutes, -0.76 at 20 minutes,-0.64 at 30 minutes, -0.89 at 40 minutes, and -0.46 at 50 minutes of interval. We also observed that the BIS drops to a lower level in patients receiving propofol (Group B) with a significant difference depicting early onset of sedation with propofol. In Group B, HR and MAP were significantly less than those of Group A. There was no significant difference in terms of mean age, sex, and body weight in the patients of both groups. CONCLUSION The BIS and RSS scores indicate a strong correlation with a magnitude of 70%-80%, but more in Group B (propofol) than Group A (midazolam). Therefore, the characteristics of each sedative drug can influence the level of sedation during spinal anaesthesia. Clinicians should use a combination of BIS values and other objective sedative methods to determine the degree of sedation, rather than relying exclusively on BIS values.
Collapse
Affiliation(s)
| | - Sofia Jaswal
- Anaesthesia, Critical Care and Pain, Homi Bhabha Cancer Hospital and Research Center, New Chandigarh, IND
| | - Harsimran S Walia
- Anaesthesia, Critical Care and Pain, Homi Bhabha Cancer Hospital and Research Center, New Chandigarh, IND
| | - Y K Batra
- Anaesthesia and Pain Management, Max Superspeciality Hospital, Mohali, IND
| |
Collapse
|
5
|
El Mokahal A, Daher HB, Yamout R, Hoshaimi N, Ayoub C, Shaib Y, Sharara AI. Randomized controlled trial of procedural sequence for same-day bidirectional endoscopy under monitored anesthesia care (RECoVER Trial). IGIE 2023; 2:282-291. [DOI: 10.1016/j.igie.2023.07.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2025]
|
6
|
Chen SC, Chen CY, Shen SJ, Tsai YF, Ko YC, Chuang LC, Lin JR, Tsai HI. Application of Bispectral Index System (BIS) Monitor to Ambulatory Pediatric Dental Patients under Intravenous Deep Sedation. Diagnostics (Basel) 2023; 13:1789. [PMID: 37238272 PMCID: PMC10216896 DOI: 10.3390/diagnostics13101789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/15/2023] [Accepted: 05/16/2023] [Indexed: 05/28/2023] Open
Abstract
Purpose Intravenous sedation has been well accepted to allow dental restoration in uncooperative children while avoiding aspiration and laryngospasm; however, intravenous anesthetics such as propofol may lead to undesired effects such as respiratory depression and delayed recovery. The use of the bispectral index system (BIS), a monitoring system reflective of the hypnotic state, is con-troversial in the reduction in the risk of respiratory adverse events (RAEs), recovery time, the in-travenous drug dosage, and post-procedural events. The aim of the study is to evaluate whether BIS is advantageous in pediatric dental procedures. Methods A total of 206 cases, aged 2-8 years, receiving dental procedures under deep sedation with propofol using target-controlled infusion (TCI) technique were enrolled in the study. BIS level was not monitored in 93 children whereas it was for 113 children, among which BIS values were maintained between 50-65. Physiological variables and adverse events were recorded. Statistical analysis was conducted using Chi-square, Mann Whitney U, Independent Samples t and Wilcoxon signed tests, with a p value of <0.05 considered to be statistically significant. Results Although no statistical significance in the post-discharge events and total amount of propofol used was observed, a clear significance was identified in periprocedural adverse events (hypoxia, apnea, and recurrent cough, all p value < 0.05) and discharge time (63.4 ± 23.2 vs. 74.5 ± 24.0 min, p value < 0.001) between these two groups. Conclusions The application of BIS in combination with TCI may be beneficial for young children undergoing deep sedation for dental procedures.
Collapse
Affiliation(s)
- Shih-Chia Chen
- Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan 333, Taiwan
| | - Chun-Yu Chen
- Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan 333, Taiwan
- College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
- Graduate Institute of Clinical Medical Sciences, Chang Gung University, Taoyuan 333, Taiwan
| | - Shih-Jyun Shen
- Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan 333, Taiwan
- College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
| | - Yung-Fong Tsai
- Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan 333, Taiwan
- College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
- Graduate Institute of Clinical Medical Sciences, Chang Gung University, Taoyuan 333, Taiwan
| | - Yu-Chen Ko
- Department of Anesthesiology, Chang Gung Memorial Hospital, Chiayi Branch, Chiayi 613, Taiwan
| | - Li-Chuan Chuang
- Department of Pediatric Dentistry, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan 333, Taiwan
- Department of Dentistry, School of Dentistry, National Yang-Ming University, Taipei 112, Taiwan
- Graduate Institute of Craniofacial and Dental Science, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
| | - Jr-Rung Lin
- Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan 333, Taiwan
- Clinical Informatics and Medical Statistics Research Center (CIMS) and Graduate Institute of Clinical Medical Sciences, Department of Biomedical Sciences, Gung Gung University, Taoyuan 333, Taiwan
| | - Hsin-I Tsai
- Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan 333, Taiwan
- College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
- Graduate Institute of Clinical Medical Sciences, Chang Gung University, Taoyuan 333, Taiwan
| |
Collapse
|
7
|
Seo Y, Lee HJ, Ha EJ, Ha TS. 2021 KSCCM clinical practice guidelines for pain, agitation, delirium, immobility, and sleep disturbance in the intensive care unit. Acute Crit Care 2022; 37:1-25. [PMID: 35279975 PMCID: PMC8918705 DOI: 10.4266/acc.2022.00094] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 02/22/2022] [Indexed: 01/12/2023] Open
Abstract
We revised and expanded the “2010 Guideline for the Use of Sedatives and Analgesics in the Adult Intensive Care Unit (ICU).” We revised the 2010 Guideline based mainly on the 2018 “Clinical Practice Guidelines for the Prevention and Management of Pain, Agitation/Sedation, Delirium, Immobility, and Sleep Disruption (PADIS) in Adult Patients in the ICU,” which was an updated 2013 pain, agitation, and delirium guideline with the inclusion of two additional topics (rehabilitation/mobility and sleep). Since it was not possible to hold face-to-face meetings of panels due to the coronavirus disease 2019 (COVID-19) pandemic, all discussions took place via virtual conference platforms and e-mail with the participation of all panelists. All authors drafted the recommendations, and all panelists discussed and revised the recommendations several times. The quality of evidence for each recommendation was classified as high (level A), moderate (level B), or low/very low (level C), and all panelists voted on the quality level of each recommendation. The participating panelists had no conflicts of interest on related topics. The development of this guideline was independent of any industry funding. The Pain, Agitation/Sedation, Delirium, Immobility (rehabilitation/mobilization), and Sleep Disturbance panels issued 42 recommendations (level A, 6; level B, 18; and level C, 18). The 2021 clinical practice guideline provides up-to-date information on how to prevent and manage pain, agitation/sedation, delirium, immobility, and sleep disturbance in adult ICU patients. We believe that these guidelines can provide an integrated method for clinicians to manage PADIS in adult ICU patients.
Collapse
|
8
|
Mizota T, Hamada M, Shiraki A, Kikuchi T, Mineharu Y, Yamao Y, Hattori EY, Yonezawa A, Furukawa K, Arakawa Y. Factors associated with somnolence during brain function mapping in awake craniotomy. J Clin Neurosci 2021; 89:349-353. [PMID: 34083112 DOI: 10.1016/j.jocn.2021.05.050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 05/12/2021] [Accepted: 05/23/2021] [Indexed: 11/18/2022]
Abstract
Somnolence during brain function mapping is one of the factors that inhibit the accomplishment of the goals of awake craniotomy. We examined the effect of anesthesia depth measured by bispectral index (BIS) during pre-awake phase on somnolence during brain function mapping and also explored the factors associated with somnolence. We examined the association between BIS values during pre-awake phase and somnolence during the first 30 min of brain function mapping in 55 patients who underwent awake craniotomy at Kyoto University Hospital from 2015 to 2018. The pre-awake BIS value was defined as the mean BIS value for 60 min before the removal of the airway. Somnolence during brain function mapping was the primary outcome, defined as either of the following conditions: inability to follow up, disorientation, or inability to assess speech function. Additionally, we compared patient or perioperative variables between patients with/without somnolence. Somnolence occurred in 14 patients (25.5%), of which 6 patients (10.9%) were unable to complete brain function mapping. There was no significant difference in the pre-awake BIS value between patients with/without somnolence (median: 46 vs. 49, P = 0.192). Somnolence was not significantly associated with age, gender, and the number of preoperative anticonvulsive drugs, but patients with somnolence had a significantly lower preoperative Western Aphasia Battery (WAB) aphasia quotient score (median 93.8 vs. 98.6, P = 0.011). We did not find an association between pre-awake BIS value and somnolence during brain function mapping. Somnolence likely occurs in patients with a low preoperative WAB aphasia quotient score.
Collapse
Affiliation(s)
- Toshiyuki Mizota
- Department of Anesthesia, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Miho Hamada
- Department of Anesthesia, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Atsuko Shiraki
- Department of Anesthesia, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Takayuki Kikuchi
- Department of Neurosurgery, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Yohei Mineharu
- Department of Neurosurgery, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Yukihiro Yamao
- Department of Neurosurgery, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Etsuko Yamamoto Hattori
- Department of Neurosurgery, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Atsushi Yonezawa
- Clinical Pharmacology and Therapeutics, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Keiko Furukawa
- Kyoto University Hospital Cancer Center, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Yoshiki Arakawa
- Department of Neurosurgery, Kyoto University Hospital, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| |
Collapse
|
9
|
Can Bispectral Index Monitoring (EEG) be an Early Predictor of Respiratory Depression under Deep Sedation during Endoscopic Retrograde Cholangiopancreatography? MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL 2020; 54:444-450. [PMID: 33364885 PMCID: PMC7751237 DOI: 10.14744/semb.2020.10476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Accepted: 07/14/2020] [Indexed: 11/20/2022]
Abstract
Objectives: The more often the endoscopy sedation is performed, the more the risk of adverse events, and therefore, advanced monitoring becomes more and more essential in endoscopy units. The present study aims to evaluate whether the Bispectral Index (BIS) monitoring is an early predictor of respiratory depression and to determine the compliance between commonly used clinical sedation score. Methods: This study was approved by the ethics committee. The sample consisted of 60 patients aged 18 to 50 years with an American Society of Anesthesiologists (ASA) physical status of I scheduled for endoscopic retrograde cholangiopancreatography (ERCP). All patients received propofol mediated sedation. Ramsay sedation score (RSS) was used as a clinical sedation score to assess the depth of sedation. Participants were attached to a BIS monitor. Perioperative hemodynamics, BIS values, the mean dose of propofol, procedure duration, apnea, frequency of oxygen desaturation and airway-related interventions, as well as demographic parameters, were recorded. BIS scores were blinded to RSS data. Results: The study sample consisted of 60 patients (36 females) aged 18 to 50 years (mean: 36.10±8.02). The mean procedure time and the dose of propofol were 32.70±1.79 min and 287.17±59.66 mg, respectively. The cut-off values for respiratory depression were as follows. At the 15th min of measurement, the BIS score of 60 had 96.2% sensitivity and 42.9% specificity. At the 20th min of measurement, the BIS score of 59.50 had 98.2% sensitivity and 100.0% specificity. At the 25th min of measurement, the BIS score of 59.00 had 98.3% sensitivity and 50.0% specificity. Regression analysis showed that the mean BIS score (p=0.000, 95%CI-0.110-0.043) increased by 0.076 with a unit increase in the RSS. Conclusion: BIS was highly correlated with RSS, and therefore, can be used to avoid respiratory depression during sedation.
Collapse
|
10
|
Kuga S, Maeda T, Ihara K. Pediatric procedural sedation in Japan: A single-facility study of 1,436 cases. Pediatr Int 2020; 62:1346-1350. [PMID: 32501599 DOI: 10.1111/ped.14331] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 05/20/2020] [Accepted: 05/29/2020] [Indexed: 11/29/2022]
Abstract
BACKGROUND Pediatric procedural sedation (PPS) has been established worldwide as standard practice for several decades. However, there are no comprehensive guidelines or multi-facility databases of PPS in Japan, and the current status of PPS and PPS-related adverse events is unclear. The objectives of this study were to investigate the status of PPS in Japan and clarify the adverse events and risk factors. METHODS This study was a single-facility, database survey performed at Oita University Hospital from September 2016 to March 2019. Children under 18 years of age who had been kept sedated for medical procedures with intravenous sedatives were enrolled in this study. Adverse events were recorded and defined according to the Quebec Guideline. RESULTS During the study period, PPS was performed for 1,436 consecutive cases. The majority (94%) of the sedatives used were thiamylal alone or thiamylal combined with ketamine. There were a total of 253 adverse events in 233 cases (16.2%), including oxygen desaturation, airway hypersensitivity, and vomiting. Patients recovered from respiratory-related adverse events immediately with simple intervention. No patient required endotracheal intubation and no severe adverse event occurred. Four risk factors (a higher American Society of Anesthesiologists classification, longer procedure time, non-compliance of nil per os status, and no Pediatric Advanced Life Support certification for sedation personnel) were associated with the occurrence of adverse events. CONCLUSIONS Adverse events occurred in 16.2% of all PPS cases. Further studies are needed to analyze the serious adverse events and risk factors for PPS in Japan.
Collapse
Affiliation(s)
- Shuji Kuga
- Department of Pediatrics, Faculty of Medicine, Oita University, Yufu, Japan
| | - Tomoki Maeda
- Department of Pediatrics, Faculty of Medicine, Oita University, Yufu, Japan
| | - Kenji Ihara
- Department of Pediatrics, Faculty of Medicine, Oita University, Yufu, Japan
| |
Collapse
|
11
|
Pharmacokinetics and Pharmacodynamics of Remimazolam (CNS 7056) after Continuous Infusion in Healthy Male Volunteers: Part II. Pharmacodynamics of Electroencephalogram Effects. Anesthesiology 2020; 132:652-666. [PMID: 31972657 DOI: 10.1097/aln.0000000000003102] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
BACKGROUND Remimazolam (CNS 7056) is a new ultra-short acting benzodiazepine for IV sedation. This study aimed to investigate the electroencephalogram (EEG) pharmacodynamics of remimazolam infusion. METHODS Twenty healthy male volunteers received remimazolam as continuous IV infusion of 5 mg/min for 5 min, 3 mg/min for the next 15 min, and 1 mg/min for further 15 min. Continuous EEG monitoring was performed by a neurophysiologic system with electrodes placed at F3, F4, C3, C4, O1, O2, Cz, and Fp1 (10/20 system) and using the Narcotrend Index. Sedation was assessed clinically by using the Modified Observer's Assessment of Alertness and Sedation scale. Pharmacodynamic models were developed for selected EEG variables and Narcotrend Index. RESULTS EEG changes during remimazolam infusion were characterized by an initial increase in beta frequency band and a late increase in delta frequency band. The EEG beta ratio showed a prediction probability of Modified Observer's Assessment of Alertness and Sedation score of 0.79, and could be modeled successfully using a standard sigmoid Emax model. Narcotrend Index showed a prediction probability of Modified Observer's Assessment of Alertness and Sedation score of 0.74. The time course of Narcotrend Index was described by an extended sigmoid Emax model with two sigmoid terms and different plasma-effect equilibration times. CONCLUSIONS Beta ratio was identified as a suitable EEG variable for monitoring remimazolam sedation. Narcotrend Index appeared less suitable than the beta ratio for monitoring the sedative effect if remimazolam is administered alone.
Collapse
|
12
|
Inal FY, Daskaya H, Yilmaz Y, Kocoglu H. Evaluation of bispectral index monitoring efficacy in endoscopic patients who underwent retrograde cholangiopancreatography and received sedoanalgesia. Wideochir Inne Tech Maloinwazyjne 2020; 15:358-365. [PMID: 32489498 PMCID: PMC7233161 DOI: 10.5114/wiitm.2020.93461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Accepted: 02/15/2020] [Indexed: 11/29/2022] Open
Abstract
INTRODUCTION Bispectral index (BIS) monitoring provides an objective, non-invasive measurement of the level of consciousness in a sedated patient. AIM In this prospective study, we aimed to investigate the hypothesis that risk of respiratory depression could be reduced and the desired level of sedation with minimal doses of propofol could be achieved by using BIS monitoring in endoscopic retrograde cholangiopancreatography (ERCP) procedures. MATERIAL AND METHODS Sixty patients in the ASA 1-2 category, who were scheduled for an ERCP with sedation, were randomly divided into two groups. The procedure was performed, and sedation was administered so that the patient's Ramsay Sedation Score (RSS) would be 4-5 in the first group (group 1) and the patient's BIS value would be 65-75 in the second group (group 2). Cardiopulmonary complications, the total duration of the procedure, and the total amount of propofol administered were recorded. RESULTS The mean SpO2 measurements at the third minute, fifth minute, and 10th minute were higher in the BIS group (p < 0.001) (p < 0.05). The mean number of respirations during the third, fifth, 10th, and 15th minute of sedation was significantly higher in the RSS group than in the BIS group (p < 0.05). There was no difference between the groups in terms of recovery time, total propofol amount, and additional doses of bolus propofol. CONCLUSIONS BIS monitoring during sedation with propofol for ERCP did not reduce total propofol use, but it may be an efficient guide for the timing of additional dose administration, which could reduce the risk of respiratory depression, and it could be used safely as an objective method in the follow-up of level of sedation.
Collapse
Affiliation(s)
- Ferda Yilmaz Inal
- Department of Anaesthesiology and Reanimation, Faculty of Medicine, Istanbul Medeniyet University, Istanbul, Turkey
| | - Hayrettin Daskaya
- Department of Anaesthesiology and Reanimation, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| | - Yadigar Yilmaz
- Clinic of Anaesthesiology and Reanimation, Sultan Abdülhamid Han Training and Research Hospital, Istanbul, Turkey
| | - Hasan Kocoglu
- Department of Anaesthesiology and Reanimation, Faculty of Medicine, Istanbul Medeniyet University, Istanbul, Turkey
| |
Collapse
|
13
|
Clinical Practice Guidelines for the Prevention and Management of Pain, Agitation/Sedation, Delirium, Immobility, and Sleep Disruption in Adult Patients in the ICU. Crit Care Med 2019; 46:e825-e873. [PMID: 30113379 DOI: 10.1097/ccm.0000000000003299] [Citation(s) in RCA: 2093] [Impact Index Per Article: 348.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To update and expand the 2013 Clinical Practice Guidelines for the Management of Pain, Agitation, and Delirium in Adult Patients in the ICU. DESIGN Thirty-two international experts, four methodologists, and four critical illness survivors met virtually at least monthly. All section groups gathered face-to-face at annual Society of Critical Care Medicine congresses; virtual connections included those unable to attend. A formal conflict of interest policy was developed a priori and enforced throughout the process. Teleconferences and electronic discussions among subgroups and whole panel were part of the guidelines' development. A general content review was completed face-to-face by all panel members in January 2017. METHODS Content experts, methodologists, and ICU survivors were represented in each of the five sections of the guidelines: Pain, Agitation/sedation, Delirium, Immobility (mobilization/rehabilitation), and Sleep (disruption). Each section created Population, Intervention, Comparison, and Outcome, and nonactionable, descriptive questions based on perceived clinical relevance. The guideline group then voted their ranking, and patients prioritized their importance. For each Population, Intervention, Comparison, and Outcome question, sections searched the best available evidence, determined its quality, and formulated recommendations as "strong," "conditional," or "good" practice statements based on Grading of Recommendations Assessment, Development and Evaluation principles. In addition, evidence gaps and clinical caveats were explicitly identified. RESULTS The Pain, Agitation/Sedation, Delirium, Immobility (mobilization/rehabilitation), and Sleep (disruption) panel issued 37 recommendations (three strong and 34 conditional), two good practice statements, and 32 ungraded, nonactionable statements. Three questions from the patient-centered prioritized question list remained without recommendation. CONCLUSIONS We found substantial agreement among a large, interdisciplinary cohort of international experts regarding evidence supporting recommendations, and the remaining literature gaps in the assessment, prevention, and treatment of Pain, Agitation/sedation, Delirium, Immobility (mobilization/rehabilitation), and Sleep (disruption) in critically ill adults. Highlighting this evidence and the research needs will improve Pain, Agitation/sedation, Delirium, Immobility (mobilization/rehabilitation), and Sleep (disruption) management and provide the foundation for improved outcomes and science in this vulnerable population.
Collapse
|
14
|
Jo YY, Kwak HJ. Sedation Strategies for Procedures Outside the Operating Room. Yonsei Med J 2019; 60:491-499. [PMID: 31124331 PMCID: PMC6536395 DOI: 10.3349/ymj.2019.60.6.491] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 04/03/2019] [Accepted: 04/09/2019] [Indexed: 02/07/2023] Open
Abstract
With the rapid development of diagnostic and therapeutic procedures performed outside the operating room (OR), the need for appropriate sedation care has emerged in importance to ensure the safety and comfort of patients and clinicians. The preparation and administration of sedatives and sedation care outside the OR require careful attention, proper monitoring systems, and clinically useful sedation guidelines. This literature review addresses proper monitoring and selection of sedatives for diagnostic and interventional procedures outside the OR. As the depth of sedation increases, respiratory depression and cardiovascular suppression become serious, necessitating careful surveillance using appropriate monitoring equipment.
Collapse
Affiliation(s)
- Youn Yi Jo
- Department of Anesthesiology and Pain Medicine, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Hyun Jeong Kwak
- Department of Anesthesiology and Pain Medicine, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea.
| |
Collapse
|
15
|
Characteristics of Reported Adverse Events During Moderate Procedural Sedation: An Update. Jt Comm J Qual Patient Saf 2018; 44:651-662. [DOI: 10.1016/j.jcjq.2018.03.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 03/16/2018] [Indexed: 01/09/2023]
|
16
|
Kim CZ, Nam KY, Lee SU, Lee SJ. Changes in Angular Deviations under General Anesthesia for Strabismus Surgery with Objective Anesthetic Depth Control. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2018. [DOI: 10.3341/jkos.2018.59.9.848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Chang Zoo Kim
- Department of Ophthalmology, Kosin University College of Medicine, Busan, Korea
| | - Ki Yup Nam
- Department of Ophthalmology, Kosin University College of Medicine, Busan, Korea
| | - Seung Uk Lee
- Department of Ophthalmology, Kosin University College of Medicine, Busan, Korea
| | - Sang Joon Lee
- Department of Ophthalmology, Kosin University College of Medicine, Busan, Korea
- Instutute for Medicine, Kosin University College of Medicine, Busan, Korea
| |
Collapse
|
17
|
Wang ZH, Chen H, Yang YL, Shi ZH, Guo QH, Li YW, Sun LP, Qiao W, Zhou GH, Yu RG, Yin K, He X, Xu M, Brochard LJ, Zhou JX. Bispectral Index Can Reliably Detect Deep Sedation in Mechanically Ventilated Patients: A Prospective Multicenter Validation Study. Anesth Analg 2017; 125:176-183. [PMID: 28027085 DOI: 10.1213/ane.0000000000001786] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Excessively deep sedation is prevalent in mechanically ventilated patients and often considered suboptimal. We hypothesized that the bispectral index (BIS), a quantified electroencephalogram instrument, would accurately detect deep levels of sedation. METHODS We prospectively enrolled 90 critically ill mechanically ventilated patients who were receiving sedation. The BIS was monitored for 24 hours and compared with the Richmond Agitation Sedation Scale (RASS) evaluated every 4 hours. Deep sedation was defined as a RASS of -3 to -5. Threshold values of baseline BIS (the lowest value before RASS assessment) and stimulated BIS (the highest value after standardized assessment) for detecting deep sedation were determined in a training set (45 patients, 262 RASS assessments). Diagnostic accuracy was then analyzed in a validation set (45 patients, 264 RASS assessments). RESULTS Deep sedation was only prescribed in 6 (6.7%) patients, but 76 patients (84.4%) had at least 1 episode of deep sedation. Thresholds for detecting deep sedation of 50 for baseline and 80 for stimulated BIS were identified, with respective areas under the receiver-operating characteristic curve of 0.771 (95% confidence interval, 0.714-0.828) and 0.805 (0.752-0.857). The sensitivity and specificity of baseline BIS were 94.0% and 66.5% and of stimulated BIS were 91.0% and 66.5%. When baseline and stimulated BIS were combined, the sensitivity, specificity, and clinical utility index were 85.0% (76.1%-91.1%), 85.9% (79.5%-90.7%), and 66.9% (57.8%-76.0%), respectively. CONCLUSIONS Combining baseline and stimulated BIS may help detect deep sedation in mechanically ventilated patients.
Collapse
Affiliation(s)
- Zhu-Heng Wang
- From the *Department of Critical Care Medicine, Beijing Tiantan Hospital, and †Department of Critical Care Medicine, Daxing Teaching Hospital, Capital Medical University, Beijing, China; ‡Surgical Intensive Care Unit, Fujian Provincial Clinical College Hospital, Fujian Medical University, Fuzhou, Fujian, China; §Intensive Care Unit, Beijing Electric Power Hospital, Capital Medical University, Beijing, China; ‖Keenan Research Centre, St Michael's Hospital, Toronto, Canada; and ¶Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
|
19
|
|
20
|
Conway A, Sutherland J. Depth of anaesthesia monitoring during procedural sedation and analgesia: A systematic review and meta-analysis. Int J Nurs Stud 2016; 63:201-212. [PMID: 27236824 DOI: 10.1016/j.ijnurstu.2016.05.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 05/03/2016] [Accepted: 05/04/2016] [Indexed: 12/15/2022]
Abstract
OBJECTIVES Processed electroencephalogram-based depth of anaesthesia monitoring devices provide an additional method to monitor level of consciousness during procedural sedation and analgesia. The objective of this systematic review was to determine whether using a depth of anaesthesia monitoring device improves the safety and efficacy of sedation. DESIGN Systematic review and meta-analysis. DATA SOURCES Electronic databases (CENTRAL; Medline; CINAHL) were searched up to May 2015. REVIEW METHODS Randomised controlled trials that compared use of a depth of anaesthesia monitoring device to a control group who received standard monitoring during procedural sedation and analgesia were included. Study selection, data extraction and risk of bias assessment (Cochrane risk of bias tool) were performed by two reviewers. Safety outcomes were hypoxaemia, hypotension and adverse events. Efficacy outcomes were amount of sedation used, duration of sedation recovery and rate of incomplete procedures. RESULTS A total of 16 trials (2138 participants) were included. Evidence ratings were downgraded to either low or moderate quality due to study limitations and imprecision. Meta-analysis of 8 trials (766 participants) found no difference in hypoxaemia (RR 0.87; 95% CI=0.67-1.12). No statistically significant difference in hypotension was observed in meta-analysis of 8 trials (RR 0.96; 95% CI=0.54-1.7; 942 participants). Mean dose of propofol was 51mg lower for participants randomised to depth of anaesthesia monitoring (95% CI=-88.7 to -13.3mg) in meta-analysis of results from four trials conducted with 434 participants who underwent interventional endoscopy procedures with propofol infusions to maintain sedation. The difference in recovery time between depth of anaesthesia and standard monitoring groups was not clinically significant (standardised mean difference -0.41; 95% CI=-0.8 to -0.02; I2=86%; 8 trials; 809 participants). CONCLUSIONS Depth of anaesthesia monitoring did impact sedation titration during interventional procedures with propofol infusions. For this reason, it seems reasonable for anaesthetists to utilise a depth of anaesthesia monitoring device for select populations of patients if it is decided that limiting the amount of sedation would be beneficial for the individual patient. However, there is no need to invest in purchasing extra equipment or training staff who are not familiar with this technology (e.g. nurses who do not routinely use a depth of anaesthesia monitoring device during general anaesthesia) because there is no high quality evidence suggestive of clear clinical benefits for patient safety or sedation efficacy.
Collapse
Affiliation(s)
- Aaron Conway
- Queensland University Technology (QUT), Institute of Health & Biomedical Innovation, Kelvin Grove Campus, Kelvin Grove, QLD 4059, Australia; Cardiac Catheter Theatres, The Wesley Hospital, Auchenflower, QLD, Australia.
| | - Joanna Sutherland
- Coffs Harbour Health Campus, Australia; Rural Clinical School University of New South Wales, Australia.
| |
Collapse
|
21
|
Peng W, Zhang T, Wang Y. Comparison of propofol-hydromorphone and propofol-dexmedetomidine in patients with intubation after maxillofacial plastic surgery. Ther Clin Risk Manag 2016; 12:373-7. [PMID: 27022268 PMCID: PMC4789838 DOI: 10.2147/tcrm.s99262] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Objective To compare the sedation and analgesic effects between propofol–hydromorphone and propofol–dexmedetomidine in patients with postoperative intubation after maxillofacial plastic surgery. Methods Forty-two patients undertaking maxillofacial plastic surgery with intubation were randomly assigned into propofol plus hydromorphone (P–H) group or propofol plus dexmedetomidine (P–D) group, receiving intravenous infusion of P–H or P–D, respectively. Cerebral state index, Ramsay sedation score, arterial blood gas analysis, and physiology indices were recorded before admission (T0), 30 minutes (T1), 1 hour (T2), 2 hours (T3), 6 hours (T4), and 12 hours after admission (T5) to intensive care unit, and 10 minutes after extubation (T6). Blood interleukin-6 was measured with enzyme-linked immunosorbent assay. Results There was no significant difference in arterial blood gas analysis, oxygen saturation, mean arterial pressure, and respiratory rate between two groups at all time-points (P>0.05). The changes of heart rate (at T4, T5, and T6), cerebral state index (T1, T2, T3, T4, and T5), and Ramsay score (at T3) in P–H group were significantly different from that in P–D group (P<0.05). The plasma interleukin-6 at T4 in P–H group was significantly lower than that in P–D group (P<0.05). Conclusion The P–H approach takes advantages over P–D approach in relieving the pain and discomfort, reducing the overstimulation of sympathetic nerve and the stress level, and enhancing the tolerance of postoperative intubation after maxillofacial plastic surgery.
Collapse
Affiliation(s)
- Wei Peng
- Department of Anesthesiology, Zhongnan Hospital, Wuhan University, Wuhan, Hubei, People's Republic of China; Department of Anesthesiology, School and Hospital of Stomatology, Wuhan University, Wuhan, Hubei, People's Republic of China
| | - Tiejun Zhang
- Department of Anesthesiology, School and Hospital of Stomatology, Wuhan University, Wuhan, Hubei, People's Republic of China
| | - Yanlin Wang
- Department of Anesthesiology, Zhongnan Hospital, Wuhan University, Wuhan, Hubei, People's Republic of China
| |
Collapse
|
22
|
Bispectral Index Versus Standard Monitoring in Sedation for Endoscopic Procedures: A Systematic Review and Meta-Analysis. Dig Dis Sci 2016; 61:814-24. [PMID: 26531839 DOI: 10.1007/s10620-015-3945-9] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2015] [Accepted: 10/22/2015] [Indexed: 01/30/2023]
Abstract
BACKGROUND Bispectral index (BIS ) monitoring has been used as an objective measurement tool for sedation depth and has been proposed as a guidance to reduce the risk of intraprocedural over-sedation. However, the results of several studies evaluating the benefits of BIS monitoring for gastrointestinal endoscopy were not consistent. AIMS This meta-analysis aimed to assess the reduction in total consumption of administrated propofol and recovery time under BIS during gastrointestinal endoscopy. METHODS Electronic databases (MEDLINE, EMBASE, WEB of SCIENCE, and the Cochrane Central Register of Controlled Trials) were searched for articles published through March 2015. After screening, the reviewers extracted information on 11 randomized controlled trials. A total of 1039 patients (526 in BIS and 513 in non-BIS group) were included in this study. RESULTS Meta-analyses showed that the total propofol consumption (the pooled standardized mean difference [SMD]: -0.15, 95% confidence interval [CI]: -0.28 to -0.01) was significantly lower in the BIS group than in the non-BIS group, although mean propofol consumption was not significantly different. Recovery time (the pooled SMD: -0.04 [95% CI -0.46 to 0.38, P = 0.85]), procedure time (the pooled SMD: 0.13 [95% CI -0.03 to 0.29, P = 0.11]), adverse events, and satisfaction-related outcomes were not significantly superior in the BIS group when compared with the non-BIS group. CONCLUSIONS This first meta-analysis showed that BIS monitoring appears to be an effective and safe method for avoiding unnecessary administration of propofol and for providing adequate sedation during endoscopic procedures.
Collapse
|
23
|
The relationship between the Bispectral Index (BIS) and the Observer Alertness of Sedation Scale (OASS) scores during propofol sedation with and without ketamine: a randomized, double blinded, placebo controlled clinical trial. J Clin Monit Comput 2015. [PMID: 26219614 DOI: 10.1007/s10877-015-9745-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Prior studies have examined the static effect of intravenous ketamine on the BIS Index for sedation but it remains unknown if the BIS Index is a reliable method to track sedation levels in the presence of ketamine. The major objective of the current investigation was to compare the BIS Vista Index ability to track varying depths of sedation as determined by OASS scores in a standardized anesthetic regimen with and without ketamine. The study was a randomized, double blinded clinical trial. Patients undergoing breast surgery under sedation with propofol were randomized to receive ketamine (1.5 μg kg min(-1)) or saline. Infusion data was used to estimate propofol plasma concentrations (Cp). The main outcome of interest was the correlation between the BIS Vista Index with the OASS score. Twenty subjects were recruited and fifteen completed the study. Four hundred fifty-five paired data points were included in the analysis. Model performance (Nagelkerke R(2)) of the multinomial logistic regression model was 0.57 with the c-statistic of 0.87 (95 % CI 0.82-0.91). Compared to awake the odds ratio for BIS values predicting moderate sedation in the saline/propofol group 1.19 (95 % CI 1.12-1.25) but only 1.06 (95 % CI 1.02-1.1) in the ketamine/propofol group (P = 0.001). There was no difference in the odds for BIS values to predict deep sedation between groups (P = 0.14). The BIS monitor can be used to monitor sedation level even when ketamine is used with propofol as part of the sedation regimen. However, ketamine reduces the value of the BIS in predicting moderate sedation levels.
Collapse
|
24
|
Amornyotin S. Registered nurse-administered sedation for gastrointestinal endoscopic procedure. World J Gastrointest Endosc 2015; 7:769-76. [PMID: 26191341 PMCID: PMC4501967 DOI: 10.4253/wjge.v7.i8.769] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2014] [Revised: 12/24/2014] [Accepted: 05/05/2015] [Indexed: 02/05/2023] Open
Abstract
The rising use of nonanesthesiologist-administered sedation for gastrointestinal endoscopy has clinical significances. Most endoscopic patients require some forms of sedation and/or anesthesia. The goals of this sedation are to guard the patient's safety, minimize physical discomfort, to control behavior and to diminish psychological responses. Generally, moderate sedation for these procedures has been offered by the non-anesthesiologist by using benzodiazepines and/or opioids. Anesthesiologists and non-anesthesiologist personnel will need to work together for these challenges and for safety of the patients. The sedation training courses including clinical skills and knowledge are necessary for the registered nurses to facilitate the patient safety and the successful procedure. However, appropriate patient selection and preparation, adequate monitoring and regular training will ensure that the use of nurse-administered sedation is a feasible and safe technique for gastrointestinal endoscopic procedures.
Collapse
|
25
|
Conway A, Sutherland J. Depth of anaesthesia monitoring during procedural sedation and analgesia: a systematic review protocol. Syst Rev 2015; 4:70. [PMID: 25982751 PMCID: PMC4465462 DOI: 10.1186/s13643-015-0061-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Accepted: 05/12/2015] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Procedural sedation and analgesia (PSA) is used to attenuate the pain and distress that may otherwise be experienced during diagnostic and interventional medical or dental procedures. As the risk of adverse events increases with the depth of sedation induced, frequent monitoring of level of consciousness is recommended. Level of consciousness is usually monitored during PSA with clinical observation. Processed electroencephalogram-based depth of anaesthesia (DoA) monitoring devices provide an alternative method to monitor level of consciousness that can be used in addition to clinical observation. However, there is uncertainty as to whether their routine use in PSA would be justified. Rigorous evaluation of the clinical benefits of DoA monitors during PSA, including comprehensive syntheses of the available evidence, is therefore required. One potential clinical benefit of using DoA monitoring during PSA is that the technology could improve patient safety by reducing sedation-related adverse events, such as death or permanent neurological disability. We hypothesise that earlier identification of lapses into deeper than intended levels of sedation using DoA monitoring leads to more effective titration of sedative and analgesic medications, and results in a reduction in the risk of adverse events caused by the consequences of over-sedation, such as hypoxaemia. The primary objective of this review is to determine whether using DoA monitoring during PSA in the hospital setting improves patient safety by reducing the risk of hypoxaemia (defined as an arterial partial pressure of oxygen below 60 mmHg or percentage of haemoglobin that is saturated with oxygen [SpO(2)] less than 90 %). Other potential clinical benefits of using DoA monitoring devices during sedation will be assessed as secondary outcomes. METHODS/DESIGN Electronic databases will be systematically searched for randomized controlled trials comparing the use of depth of anaesthesia monitoring devices with clinical observation of level of consciousness during PSA. Language restrictions will not be imposed. Screening, study selection and data extraction will be performed by two independent reviewers. Disagreements will be resolved by discussion. Meta-analyses will be performed if suitable. DISCUSSION This review will synthesise the evidence on an important potential clinical benefit of DoA monitoring during PSA within hospital settings. SYSTEMATIC REVIEW REGISTRATION PROSPERO CRD42015017251.
Collapse
Affiliation(s)
- Aaron Conway
- Institute of Health & Biomedical Innovation, Queensland University Technology, Kelvin Grove Campus, Kelvin Grove, Queensland, 4059, Australia. .,Cardiac Catheter Theatres, The Wesley Hospital, Auchenflower, Queensland, Australia.
| | - Joanna Sutherland
- Coffs Harbour Health Campus, Coffs Harbour, Australia. .,Rural Clinical School, University of New South Wales, Sydney, Australia.
| |
Collapse
|
26
|
Kumar P. Myths, fallacies and practical pearls in GI lab. World J Gastrointest Endosc 2014; 6:584-91. [PMID: 25512767 PMCID: PMC4265955 DOI: 10.4253/wjge.v6.i12.584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Revised: 10/07/2014] [Accepted: 10/31/2014] [Indexed: 02/05/2023] Open
Abstract
Many prevalent practices and guidelines related to Gastrointestinal endoscopy and procedural sedation are at odds with the widely available scientific-physiological and clinical outcome data. In many institutions, strict policy of pre-procedural extended fasting is still rigorously enforced, despite no evidence of increased incidence of aspiration after recent oral intake prior to sedation. Supplemental oxygen administration in the setting of GI procedural sedation has been increasingly adopted as reported in the medical journals, despite clear evidence that supplemental oxygen blunts the usefulness of pulse oximetry in timely detection of sedation induced hypoventilation, leading to increased number of adverse cardiopulmonary outcomes. Use of Propofol by Gastroenterologist-Nurse team is erroneously considered dangerous and often prohibited in various institutions, at the same time worldwide reports of remarkable safety and patient satisfaction continue to be published, dating back more than a decade. Of patient monitoring practices that have been advocated to be standard, many merely add cost, not value. Advances in the technology often are not incorporated in a timely manner in guidelines or clinical practices, e.g., Capsule endoscopy or electrocautery during GI procedures do not interfere with proper functioning of the current pacemakers or defibrillators. Orthopedic surgeons have continued to recommend prophylactic antibiotics for joint replacement patients prior to GI procedures, without any evidence of need. These myths are explored for a succint review to prompt a change in clinical practices and institutional policies.
Collapse
|
27
|
|
28
|
Mason K. Challenges in paediatric procedural sedation: political, economic, and clinical aspects. Br J Anaesth 2014; 113 Suppl 2:ii48-62. [DOI: 10.1093/bja/aeu387] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
|
29
|
Seiden SC, McMullan S, Sequera-Ramos L, De Oliveira GS, Roth A, Rosenblatt A, Jesdale BM, Suresh S. Tablet-based Interactive Distraction (TBID) vs oral midazolam to minimize perioperative anxiety in pediatric patients: a noninferiority randomized trial. Paediatr Anaesth 2014; 24:1217-23. [PMID: 25040433 DOI: 10.1111/pan.12475] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/02/2014] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Perioperative anxiety is a common and undesirable outcome in pediatric surgical patients. The use of interactive tools to minimize perioperative anxiety is vastly understudied. The main objective of the current investigation was to compare the effects of a tablet-based interactive distraction (TBID) tool to oral midazolam on perioperative anxiety. We hypothesized that the TBID tool was not inferior to midazolam to reduce perioperative anxiety. METHODS 108 children, ages 1-11 years, presenting for outpatient surgical procedures were prospectively randomized to oral midazolam (0.5 mg·kg(-1); 20 mg max) or TBID. The primary outcome was the change in anxiety level from baseline to parental separation and anesthetic induction. Other data collected included emergence delirium, parental satisfaction, time-to-PACU discharge, and posthospitalization behavior. RESULTS The mean difference (95% CI) in the increase of anxiety at parental separation between the TBID and the midazolam group was -9 (-2.6 to -16.4), P = 0.006, demonstrating superiority to midazolam group (one-sided P = 0.003). For children 2-11 years, the mean difference (95% CI) in anxiety at induction was significant between the TBID and midazolam groups, -14.0 (-6.1 to -22.0), P < 0.001. The median (IQR) time-to-PACU discharge was 111 (75-197) min in the midazolam group and 87 (55-137) min in the TBID group, P = 0.03. Decreased emergence delirium and increased parental satisfaction were also observed in the TBID group. CONCLUSIONS A TBID tool reduces perioperative anxiety, emergence delirium, and time-to-discharge and increases parental satisfaction when compared to midazolam in pediatric patients undergoing ambulatory surgery.
Collapse
Affiliation(s)
- Samuel C Seiden
- Department of Pediatric Anesthesiology, Ann & Robert H. Lurie Children's Hospital of Chicago, Northwestern University, Chicago, IL, USA
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Rosow C. Improving safety during sedation by nonanesthesiologists: do we lead or follow? Anesth Analg 2014; 119:7-8. [PMID: 24945117 DOI: 10.1213/ane.0000000000000277] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Carl Rosow
- From the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|