1
|
Beshara M, Bagchi A. Dynamic Right Ventricular Outflow Tract Obstruction: An Often-Overlooked Cause of Hemodynamic Instability After Cardiac Surgery. J Cardiothorac Vasc Anesth 2024; 38:2035-2040. [PMID: 38897889 DOI: 10.1053/j.jvca.2024.05.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 04/24/2024] [Accepted: 05/20/2024] [Indexed: 06/21/2024]
Affiliation(s)
- Michael Beshara
- University of Kansas Medical Center, Department of Anesthesiology, Kansas City, KS
| | - Aranya Bagchi
- Massachusetts General Hospital, Harvard Medical School, Department of Anesthesiology, Boston, MA.
| |
Collapse
|
2
|
Denault A, Couture EJ, Perry T, Saade E, Calderone A, Zeng YH, Scherb D, Moses K, Potes C, Hammoud A, Beaubien-Souligny W, Elmi-Sarabi M, Grønlykke L, Lamarche Y, Lebon JS, Rousseau-Saine N, Desjardins G, Rochon A. Continuous Right Ventricular Pressure Monitoring in Cardiac Surgery. J Cardiothorac Vasc Anesth 2024; 38:1673-1682. [PMID: 38862285 DOI: 10.1053/j.jvca.2024.04.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 04/10/2024] [Accepted: 04/19/2024] [Indexed: 06/13/2024]
Abstract
OBJECTIVE Right ventricular (RV) dysfunction in cardiac surgery can lead to RV failure, which is associated with increased morbidity and mortality. Abnormal RV function can be identified using RV pressure monitoring. The primary objective of the study is to determine the proportion of patients with abnormal RV early to end-diastole diastolic pressure gradient (RVDPG) and abnormal RV end-diastolic pressure (RVEDP) before initiation and after cardiopulmonary bypass (CPB) separation. The secondary objective is to evaluate if RVDPG before CPB initiation is associated with difficult and complex separation from CPB, RV dysfunction, and failure at the end of cardiac surgery. DESIGN Prospective study. SETTING Tertiary care cardiac institute. PARTICIPANTS Cardiac surgical patients. INTERVENTION Cardiac surgery. MEASUREMENTS AND MAIN RESULTS Automated electronic quantification of RVDPG and RVEDP were obtained. Hemodynamic measurements were correlated with cardiac and extracardiac parameters from transesophageal echocardiography and postoperative complications. Abnormal RVDPG was present in 80% of the patients (n = 105) at baseline, with a mean RVEDP of 14.2 ± 3.9 mmHg. Patients experienced an RVDPG > 4 mmHg for a median duration of 50.2% of the intraoperative period before CPB initiation and 60.6% after CPB separation. A total of 46 (43.8%) patients had difficult/complex separation from CPB, 18 (38.3%) patients had RV dysfunction, and 8 (17%) had RV failure. Abnormal RVDPG before CPB was not associated with postoperative outcome. CONCLUSION Elevated RVDPG and RVEDP are common in cardiac surgery. RVDPG and RVEDP before CPB initiation are not associated with RV dysfunction and failure but can be used to diagnose them.
Collapse
Affiliation(s)
- André Denault
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada.
| | - Etienne J Couture
- Department of Anesthesiology, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Quebec City, Quebec, Canada
| | - Tjorvi Perry
- Department of Anesthesiology, University of Minnesota, Minneapolis, MN, USA
| | - Elena Saade
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Alexander Calderone
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Yu Hao Zeng
- Departments of Medicine and of Family Medicine, Jewish General Hospital, McGill University Health Centre, Montreal, Quebec, Canada
| | | | | | | | - Ali Hammoud
- Division of Critical Care, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | | | - Mahsa Elmi-Sarabi
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Lars Grønlykke
- Department of Cardiothoracic Anaesthesiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark
| | - Yoan Lamarche
- Department of Cardiothoracic Surgery, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Jean-Sébastien Lebon
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Nicolas Rousseau-Saine
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Georges Desjardins
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Antoine Rochon
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| |
Collapse
|
3
|
Alsallamin I, Quraiba L, Mtour S, Alsallamin A. Cardiac Metastasis Presenting As Right Ventricular Outflow Obstruction. Cureus 2023; 15:e49720. [PMID: 38161843 PMCID: PMC10757555 DOI: 10.7759/cureus.49720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/29/2023] [Indexed: 01/03/2024] Open
Abstract
Right ventricular outflow tract obstruction (RVOTO) is characterized by an increased systolic pressure gradient between the right ventricle (RV) and the pulmonary artery. This rare condition can be diagnosed via echocardiography and may arise from various causes, including cardiac masses, pulmonary atresia with a ventricular septal defect, tricuspid valve thrombus, graft or wire calcification, or a cardiac tumor. We present the case of a 73-year-old male who was hospitalized after a syncope episode. Telemetry detected ventricular arrhythmia. Imaging identified a mass compressing the RV, causing RVOTO. A biopsy of the mass confirmed it as squamous cell carcinoma, which likely originated from the lung as a distant metastasis.
Collapse
Affiliation(s)
- Isaac Alsallamin
- Clinical Medicine, Northeast Ohio Medical University, Cleveland, USA
- Internal Medicine, St. Vincent Charity Medical Center, Cleveland, USA
- Internal Medicine, Case Western Reserve University School of Medicine, Cleveland, USA
- Internal Medicine, University Hospitals Cleveland Medical Center, Cleveland, USA
| | - Lama Quraiba
- Medicine, Alfaisal University College of Medicine, Riyadh, SAU
| | - Sameer Mtour
- Cardiology, Al-Makassed Hospital, Jerusalem, PSE
| | - Afnan Alsallamin
- Internal Medicine, St. Vincent Charity Medical Center, Cleveland, USA
| |
Collapse
|
4
|
Elmi-Sarabi M, Jarry S, Couture EJ, Haddad F, Cogan J, Sweatt AJ, Rousseau-Saine N, Beaubien-Souligny W, Fortier A, Denault AY. Pulmonary Vasodilator Response of Combined Inhaled Epoprostenol and Inhaled Milrinone in Cardiac Surgical Patients. Anesth Analg 2023; 136:282-294. [PMID: 36121254 DOI: 10.1213/ane.0000000000006192] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Pulmonary hypertension (PH) and right ventricular (RV) dysfunction are major complications in cardiac surgery. Intraoperative management of patients at high risk of RV failure should aim to reduce RV afterload and optimize RV filling pressures, while avoiding systemic hypotension, to facilitate weaning from cardiopulmonary bypass (CPB). Inhaled epoprostenol and inhaled milrinone (iE&iM) administered in combination before CPB may represent an effective strategy to facilitate separation from CPB and reduce requirements for intravenous inotropes during cardiac surgery. Our primary objective was to report the rate of positive pulmonary vasodilator response to iE&iM and, second, how it relates to perioperative outcomes in cardiac surgery. METHODS This is a retrospective cohort study of consecutive patients with PH or RV dysfunction undergoing on-pump cardiac surgery at the Montreal Heart Institute from July 2013 to December 2018 (n = 128). iE&iM treatment was administered using an ultrasonic mesh nebulizer before the initiation of CPB. Demographic and baseline clinical data, as well as hemodynamic, intraoperative, and echocardiographic data, were collected using electronic records. An increase of 20% in the mean arterial pressure (MAP) to mean pulmonary artery pressure (MPAP) ratio was used to indicate a positive response to iE&iM. RESULTS In this cohort, 77.3% of patients were responders to iE&iM treatment. Baseline systolic pulmonary artery pressure (SPAP) (odds ratio [OR], 1.63; 95% confidence interval [CI], 1.24-2.16 per 5 mm Hg; P = .0006) was found to be a predictor of pulmonary vasodilator response, while a European System for Cardiac Operative Risk Evaluation (EuroSCORE II) score >6.5% was a predictor of nonresponse to treatment (≤6.5% vs >6.5% [reference]: OR, 5.19; 95% CI, 1.84-14.66; P = .002). Severity of PH was associated with a positive response to treatment, where a higher proportion of responders had MPAP values >30 mm Hg (42.4% responders vs 24.1% nonresponders; P = .0237) and SPAP values >55 mm Hg (17.2% vs 3.4%; P = .0037). Easier separation from CPB was also associated with response to iE&iM treatment (69.7% vs 58.6%; P = .0181). A higher proportion of nonresponders had a very difficult separation from CPB and required intravenous inotropic drug support compared to responders, for whom easy separation from CPB was more frequent. Use of intravenous inotropes after CPB was lower in responders to treatment (8.1% vs 27.6%; P = .0052). CONCLUSIONS A positive pulmonary vasodilator response to treatment with a combination of iE&iM before initiation of CPB was observed in 77% of patients. Higher baseline SPAP was an independent predictor of pulmonary vasodilator response, while EuroSCORE II >6.5% was a predictor of nonresponse to treatment.
Collapse
Affiliation(s)
- Mahsa Elmi-Sarabi
- From the Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Stéphanie Jarry
- From the Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Etienne J Couture
- Department of Anesthesiology, Department of Medicine, Division of Intensive Care Medicine, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Quebec, Canada
| | - François Haddad
- Department of Cardiovascular Medicine, Stanford University, Stanford, California
| | - Jennifer Cogan
- From the Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Andrew J Sweatt
- Division of Pulmonary, Allergy and Critical Care Medicine, Stanford University, Stanford, California
| | - Nicolas Rousseau-Saine
- From the Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - William Beaubien-Souligny
- Division of Nephrology, Centre Hospitalier de l'Université de Montréal (CHUM) and Innovation Hub, Research Centre CHUM, Montreal, Quebec, Canada
| | - Annik Fortier
- Department of Statistics, Montreal Health Innovations Coordinating Center, Montreal Heart Institute, Montreal, Quebec, Canada
| | - André Y Denault
- From the Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada.,Division of Critical Care, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada
| |
Collapse
|
5
|
Longitudinal Validation of Right Ventricular Pressure Monitoring for the Assessment of Right Ventricular Systolic Dysfunction in a Large Animal Ischemic Model. Crit Care Explor 2023; 5:e0847. [PMID: 36699251 PMCID: PMC9851694 DOI: 10.1097/cce.0000000000000847] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Right ventricular (RV) dysfunction is a major cause of morbidity and mortality in intensive care and cardiac surgery. Early detection of RV dysfunction may be facilitated by continuous monitoring of RV waveform obtained from a pulmonary artery catheter. The objective is to evaluate the extent to which RV pressure monitoring can detect changes in RV systolic performance assess by RV end-systolic elastance (Ees) following the development of an acute RV ischemic in a porcine model. HYPOTHESIS RV pressure monitoring can detect changes in RV systolic performance assess by RV Ees following the development of an acute RV ischemic model. METHODS AND MODELS Acute ischemic RV dysfunction was induced by progressive embolization of microsphere in the right coronary artery to mimic RV dysfunction clinically experienced during cardiopulmonary bypass separation caused by air microemboli. RV hemodynamic performance was assessed using RV pressure waveform-derived parameters and RV Ees obtained using a conductance catheter during inferior vena cava occlusions. RESULTS Acute ischemia resulted in a significant reduction in RV Ees from 0.26 mm Hg/mL (interquartile range, 0.16-0.32 mm Hg/mL) to 0.14 mm Hg/mL (0.11-0.19 mm Hg/mL; p < 0.010), cardiac output from 6.3 L/min (5.7-7 L/min) to 4.5 (3.9-5.2 L/min; p = 0.007), mean systemic arterial pressure from 72 mm Hg (66-74 mm Hg) to 51 mm Hg (46-56 mm Hg; p < 0.001), and mixed venous oxygen saturation from 65% (57-72%) to 41% (35-45%; p < 0.001). Linear mixed-effect model analysis was used to assess the relationship between Ees and RV pressure-derived parameters. The reduction in RV Ees best correlated with a reduction in RV maximum first derivative of pressure during isovolumetric contraction (dP/dtmax) and single-beat RV Ees. Adjusting RV dP/dtmax for heart rate resulted in an improved surrogate of RV Ees. INTERPRETATION AND CONCLUSIONS Stepwise decreases in RV Ees during acute ischemic RV dysfunction were accurately tracked by RV dP/dtmax derived from the RV pressure waveform.
Collapse
|
6
|
Saade E, Couture EJ, Robillard J, Denault A. A Word of Caution on Right Ventricular Pressure Monitoring Using the Paceport Pulmonary Artery Catheter. J Cardiothorac Vasc Anesth 2022; 36:4223-4226. [PMID: 35961849 DOI: 10.1053/j.jvca.2022.06.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/20/2022] [Accepted: 06/22/2022] [Indexed: 11/11/2022]
Affiliation(s)
- Elena Saade
- Biomedical Science Program, Department of Medicine, Université de Montréal, Montreal, Quebec, Canada; Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Etienne J Couture
- Department of Anesthesiology, Department of Medicine, Division of Intensive Care Medicine, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Quebec City, Quebec, Canada
| | - Julie Robillard
- Department of Radiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - André Denault
- Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada.
| |
Collapse
|