• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4594739)   Today's Articles (5443)   Subscriber (49325)
For: Yao JQ, Parry TV, Unsworth A, Cunningham JL. Contact Mechanics of Soft Layer Artificial Hip Joints: Part 2: Application to Joint Design. Proc Inst Mech Eng H 2016. [DOI: 10.1243/pime_proc_1994_208_290_02] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Number Cited by Other Article(s)
1
Wahab AHA, Saad APM, Harun MN, Syahrom A, Ramlee MH, Sulong MA, Kadir MRA. Developing functionally graded PVA hydrogel using simple freeze-thaw method for artificial glenoid labrum. J Mech Behav Biomed Mater 2019;91:406-415. [DOI: 10.1016/j.jmbbm.2018.12.033] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 12/18/2018] [Accepted: 12/20/2018] [Indexed: 12/18/2022]
2
Yao JQ. Contact Mechanics of Soft Layer Artificial Hip Joints: Part 1: General Solutions. Proc Inst Mech Eng H 2016. [DOI: 10.1243/pime_proc_1994_208_289_02] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
3
Ma Y, Zheng Y, Huang X, Xi T, Lin X, Han D, Song W. Mineralization behavior and interface properties of BG-PVA/bone composite implants in simulated body fluid. Biomed Mater 2010;5:25003. [DOI: 10.1088/1748-6041/5/2/025003] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
4
Ciavarella M, Strozzi A, Baldini A, Giacopini M. Normalization of load and clearance effects in ball-in-socket-like replacements. Proc Inst Mech Eng H 2007;221:601-11. [PMID: 17937199 DOI: 10.1243/09544119jeim200] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
5
Scholes SC, Burgess IC, Marsden HR, Unsworth A, Jones E, Smith N. Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint. Proc Inst Mech Eng H 2006;220:583-96. [PMID: 16898216 DOI: 10.1243/09544119h06404] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
6
Scholes SC, Unsworth A, Blamey JM, Burgess IC, Jones E, Smith N. Design aspects of compliant, soft layer bearings for an experimental hip prosthesis. Proc Inst Mech Eng H 2005;219:79-87. [PMID: 15819479 DOI: 10.1243/095441105x9318] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
7
Strozzi A. Analytical modelling of the elastomeric layer in soft layer hip replacements. Proc Inst Mech Eng H 2000;214:69-81. [PMID: 10718052 DOI: 10.1243/0954411001535255] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
8
Smeathers JE, Wright V. Soft Tissue Biomechanics. Proc Inst Mech Eng H 1994. [DOI: 10.1243/pime_proc_1994_208_288_02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA