1
|
Ansari SR, Imhoff ED, Suárez-López YDC, Melnyk A, Rinaldi-Ramos CM, Teleki A. Flame-Made Doped Iron Oxide Nanoparticles as Tracers for Magnetic Particle Imaging. CHEMISTRY OF MATERIALS : A PUBLICATION OF THE AMERICAN CHEMICAL SOCIETY 2025; 37:4071-4084. [PMID: 40520624 PMCID: PMC12159977 DOI: 10.1021/acs.chemmater.5c00331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2025] [Revised: 05/09/2025] [Accepted: 05/12/2025] [Indexed: 06/18/2025]
Abstract
Magnetic particle imaging (MPI) is an emerging imaging modality that shows potential in tumor imaging, cell tracking, and angiography. It uses the signal generated from superparamagnetic iron oxide nanoparticles (SPIONs) with zero attenuation in tissue, showing excellent sensitivity and contrast. MPI resolution and sensitivity are dependent on the nonlinear dynamic magnetization of the SPION tracer and can be improved by tuning their magnetic properties. Doping SPIONs with manganese or zinc is an effective and biocompatible route to modify the magnetic properties of SPIONs. This study developed SPIONs doped with manganese or zinc as MPI tracers using flame spray pyrolysis (FSP), a highly scalable synthesis technique. The MPI performance was evaluated with a MOMENTUM imager. Postsynthesis citrate coating and filtration significantly enhanced the MPI resolution of SPIONs. The Zn-doped SPIONs exhibited the best resolution, while Mn-doped SPIONs showed the highest sensitivity. The overall MPI performance of all tracers was closely linked to their magnetic diameter and susceptibility, but deviated noticeably from the predictions of the Langevin model. Zn-doped SPIONs were encapsulated in a water-dispersible nanocarrier using flash nanoprecipitation (FNP), circumventing the need for citrate coating while preserving MPI performance. These findings show that the hydrodynamic size, size distribution, and composition of the SPIONs are critical to MPI performance and highlight the potential of combining FSP and FNP for large-scale production of the MPI tracers.
Collapse
Affiliation(s)
- Shaquib Rahman Ansari
- Department
of Pharmacy, Science for Life Laboratory, Uppsala University, 75123Uppsala, Sweden
| | - Eric Daniel Imhoff
- Department
of Chemical Engineering and J. Crayton Pruitt Family Department of
Biomedical Engineering, University of Florida, Gainesville, Florida32611-6005, United
States
| | | | - Andrii Melnyk
- Department
of Chemical Engineering and J. Crayton Pruitt Family Department of
Biomedical Engineering, University of Florida, Gainesville, Florida32611-6005, United
States
| | - Carlos M. Rinaldi-Ramos
- Department
of Chemical Engineering and J. Crayton Pruitt Family Department of
Biomedical Engineering, University of Florida, Gainesville, Florida32611-6005, United
States
| | - Alexandra Teleki
- Department
of Pharmacy, Science for Life Laboratory, Uppsala University, 75123Uppsala, Sweden
| |
Collapse
|
2
|
Wang Q, Zhang Z, Li L, Schrank F, Zeng Y, Guo P, Radermacher H, Schulz V, Zhu S. Single-Sided Magnetic Particle Imaging Device With Offset Field Based Spatial Encoding. IEEE TRANSACTIONS ON MEDICAL IMAGING 2025; 44:1878-1889. [PMID: 40030836 DOI: 10.1109/tmi.2024.3522979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/05/2025]
Abstract
Single-sided Magnetic Particle Imaging (MPI) devices enable easy imaging of areas outside the MPI device, allowing objects of any size to be imaged and improving clinical applicability. However, current single-sided MPI devices face challenges in generating high-gradient selection fields and experience a decrease in gradient strength with increasing detection depth, which limits the detection depth and resolution. We introduce a novel spatial encoding method. This method combines high-frequency alternating excitation fields with variable offset fields, leveraging the inherent characteristic of single-sided MPI devices where the magnetic field strength attenuates with distance. Consequently, the harmonic signals of particle responses at different spatial positions vary. By manipulating multiple offset fields, we correlate the nonlinear harmonic responses of magnetic particles with spatial position data. In this work, we employed an image reconstruction using a system matrix approach, which takes into account the spatial distribution of the magnetic field during the movement of the device within the field of view. Our proposed encoding approach eliminates the need for the classical selection field and directly links the spatial resolution to the strength and spatial distribution of the magnetic field, thus reducing the dependency of resolution on selection field gradients strength. We have demonstrated the feasibility of the proposed method through simulations and phantom measurements.
Collapse
|
3
|
Velazquez-Albino AC, Imhoff ED, Rinaldi-Ramos CM. Advances in engineering nanoparticles for magnetic particle imaging (MPI). SCIENCE ADVANCES 2025; 11:eado7356. [PMID: 39772674 PMCID: PMC11708890 DOI: 10.1126/sciadv.ado7356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 12/03/2024] [Indexed: 01/11/2025]
Abstract
Magnetic particle imaging (MPI) is an emerging imaging modality with exciting biomedical applications, such as cell tracking, blood pool imaging, and image-guided magnetic hyperthermia. MPI is unique in that signal is generated entirely by synthetic nanoparticle tracers, motivating precise engineering of magnetic nanoparticle properties including size, shape, composition, and coating to address the needs of specific applications. However, success in many applications and in clinical transition requires development of high-sensitivity and high-resolution tracers, for which there is considerable room for improvement. This review summarizes recent advancements in MPI tracer synthesis and compares reported tracers in terms of sensitivity and resolution. In making these comparisons, we point out inconsistencies in reporting of MPI tracer properties. To overcome this challenge, we propose a list of properties to standardize characterization and reporting of new MPI tracers and improve communication within the field.
Collapse
Affiliation(s)
| | - Eric Daniel Imhoff
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Carlos M. Rinaldi-Ramos
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611, USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131, USA
| |
Collapse
|
4
|
Le TA, Phu Bui M, Hadadian Y, Mohamed Gadelmowla K, Oh S, Im C, Hahn S, Yoon J. Toward Human-Scale Magnetic Particle Imaging: Development of the First System With Superconductor- Based Selection Coils. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:4266-4280. [PMID: 38923478 DOI: 10.1109/tmi.2024.3419427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Magnetic Particle Imaging (MPI) is an emerging tomographic modality that allows for precise three-dimensional (3D) mapping of magnetic nanoparticles (MNPs) concentration and distribution. Although significant progress has been made towards improving MPI since its introduction, scaling it up for human applications has proven challenging. High-quality images have been obtained in animal-scale MPI scanners with gradients up to 7 T/m/ , however, for MPI systems with bore diameters around 200 mm the gradients generated by electromagnets drop significantly to below 0.5 T/m/ . Given the current technological limitations in image reconstruction and the properties of available MNPs, these low gradients inherently impose limitations on improving MPI resolution for higher precision medical imaging. Utilizing superconductors stands out as a promising approach for developing a human-scale MPI system. In this study, we introduce, for the first time, a human-scale amplitude modulation (AM) MPI system with superconductor-based selection coils. The system achieves an unprecedented magnetic field gradient of up to 2.5 T/m/ within a 200 mm bore diameter, enabling large fields of view of mm3 at 2.5 T/m/ for 3D imaging. While obtained spatial resolution is in the order of previous animal-scale AM MPIs, incorporating superconductors for achieving such high gradients in a 200 mm bore diameter marks a major step toward clinical MPI.
Collapse
|
5
|
Trozzo S, Neupane B, Foster PJ. A Comparison of the Sensitivity and Cellular Detection Capabilities of Magnetic Particle Imaging and Bioluminescence Imaging. Tomography 2024; 10:1846-1866. [PMID: 39590944 PMCID: PMC11598277 DOI: 10.3390/tomography10110135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 11/11/2024] [Accepted: 11/13/2024] [Indexed: 11/28/2024] Open
Abstract
BACKGROUND Preclinical cell tracking is enhanced with a multimodal imaging approach. Bioluminescence imaging (BLI) is a highly sensitive optical modality that relies on engineering cells to constitutively express a luciferase gene. Magnetic particle imaging (MPI) is a newer imaging modality that directly detects superparamagnetic iron oxide (SPIO) particles used to label cells. Here, we compare BLI and MPI for imaging cells in vitro and in vivo. METHODS Mouse 4T1 breast carcinoma cells were transduced to express firefly luciferase, labeled with SPIO (ProMag), and imaged as cell samples after subcutaneous injection into mice. RESULTS For cell samples, the BLI and MPI signals were strongly correlated with cell number. Both modalities presented limitations for imaging cells in vivo. For BLI, weak signal penetration, signal attenuation, and scattering prevented the detection of cells for mice with hair and for cells far from the tissue surface. For MPI, background signals obscured the detection of low cell numbers due to the limited dynamic range, and cell numbers could not be accurately quantified from in vivo images. CONCLUSIONS It is important to understand the shortcomings of these imaging modalities to develop strategies to improve cellular detection sensitivity.
Collapse
Affiliation(s)
- Sophia Trozzo
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada; (B.N.); (P.J.F.)
- Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada
| | - Bijita Neupane
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada; (B.N.); (P.J.F.)
| | - Paula J. Foster
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada; (B.N.); (P.J.F.)
- Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada
| |
Collapse
|
6
|
Tay RE, P L, Pang ST, Low KE, Tay HC, Ho CM, Malleret B, Rötzschke O, Olivo M, Tay ZW. High-efficiency magnetophoretic labelling of adoptively-transferred T cells for longitudinal in vivo Magnetic Particle Imaging. Theranostics 2024; 14:6138-6160. [PMID: 39431019 PMCID: PMC11488102 DOI: 10.7150/thno.95527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Accepted: 08/07/2024] [Indexed: 10/22/2024] Open
Abstract
While adoptive cell therapies (ACT) have been successful as therapies for blood cancers, they have limited efficacy in treating solid tumours, where the tumour microenvironment excludes and suppresses adoptively transferred tumour-specific immune cells. A major obstacle to improving cell therapies for solid tumours is a lack of accessible and quantitative imaging modalities capable of tracking the migration and immune functional activity of ACT products for an extended duration in vivo. Methods: A high-efficiency magnetophoretic method was developed for facile magnetic labelling of hard-to-label immune cells, which were then injected into tumour-bearing mice and imaged over two weeks with a compact benchtop Magnetic Particle Imager (MPI) design. Results: Labelling efficiency was improved more than 10-fold over prior studies enabling longer-term tracking for at least two weeks in vivo of the labelled immune cells and their biodistribution relative to the tumour. The new imager showed 5-fold improved throughput enabling much larger density of data (up to 20 mice per experiment). Conclusions: Taken together, our innovations enable the convenient and practical use of MPI to visualise the localisation of ACT products in in vivo preclinical models for longitudinal, non-invasive functional evaluation of therapeutic efficacy.
Collapse
Affiliation(s)
- Rong En Tay
- Singapore Immunology Network (SIgN), Agency for Science, Technology and Research (A*STAR), 8A Biomedical Grove, #04-06 Immunos, Singapore 138648, Republic of Singapore
| | - Lokamitra P
- Singapore Immunology Network (SIgN), Agency for Science, Technology and Research (A*STAR), 8A Biomedical Grove, #04-06 Immunos, Singapore 138648, Republic of Singapore
- Institute of Bioengineering and Bioimaging (IBB), Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02 Helios Building, Singapore 138667, Republic of Singapore
| | - Shun Toll Pang
- Institute of Bioengineering and Bioimaging (IBB), Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02 Helios Building, Singapore 138667, Republic of Singapore
| | - Kay En Low
- Electron Microscopy Unit, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117597, Republic of Singapore
| | - Hui Chien Tay
- Singapore Immunology Network (SIgN), Agency for Science, Technology and Research (A*STAR), 8A Biomedical Grove, #04-06 Immunos, Singapore 138648, Republic of Singapore
| | - Charmaine Min Ho
- Singapore Immunology Network (SIgN), Agency for Science, Technology and Research (A*STAR), 8A Biomedical Grove, #04-06 Immunos, Singapore 138648, Republic of Singapore
| | - Benoit Malleret
- Electron Microscopy Unit, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117597, Republic of Singapore
- Department of Microbiology and Immunology, Immunology Translational Research Programme, Yong Loo Lin School of Medicine, National University of Singapore, Republic of Singapore
| | - Olaf Rötzschke
- Singapore Immunology Network (SIgN), Agency for Science, Technology and Research (A*STAR), 8A Biomedical Grove, #04-06 Immunos, Singapore 138648, Republic of Singapore
- Department of Microbiology and Immunology, Immunology Translational Research Programme, Yong Loo Lin School of Medicine, National University of Singapore, Republic of Singapore
- School of Biological Sciences, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Republic of Singapore
| | - Malini Olivo
- A*STAR Skin Research Labs (A*SRL), Agency for Science, Technology and Research (A*STAR), 31 Biopolis Way, #07-01 Nanos, Singapore 138669, Republic of Singapore
| | - Zhi Wei Tay
- Institute of Bioengineering and Bioimaging (IBB), Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02 Helios Building, Singapore 138667, Republic of Singapore
- National Institute of Advanced Industrial Science and Technology (AIST), Health and Medical Research Institute (HMRI), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan
| |
Collapse
|
7
|
Pacheco MO, Gerzenshtein IK, Stoppel WL, Rinaldi-Ramos CM. Advances in Vascular Diagnostics using Magnetic Particle Imaging (MPI) for Blood Circulation Assessment. Adv Healthc Mater 2024; 13:e2400612. [PMID: 38879782 PMCID: PMC11442126 DOI: 10.1002/adhm.202400612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 05/11/2024] [Indexed: 06/29/2024]
Abstract
Rapid and accurate assessment of conditions characterized by altered blood flow, cardiac blood pooling, or internal bleeding is crucial for diagnosing and treating various clinical conditions. While widely used imaging modalities such as magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound offer unique diagnostic advantages, they fall short for specific indications due to limited penetration depth and prolonged acquisition times. Magnetic particle imaging (MPI), an emerging tracer-based technique, holds promise for blood circulation assessments, potentially overcoming existing limitations with reduction in background signals and high temporal and spatial resolution, below the millimeter scale. Successful imaging of blood pooling and impaired flow necessitates tracers with diverse circulation half-lives optimized for MPI signal generation. Recent MPI tracers show potential in imaging cardiovascular complications, vascular perforations, ischemia, and stroke. The impressive temporal resolution and penetration depth also position MPI as an excellent modality for real-time vessel perfusion imaging via functional MPI (fMPI). This review summarizes advancements in optimized MPI tracers for imaging blood circulation and analyzes the current state of pre-clinical applications. This work discusses perspectives on standardization required to transition MPI from a research endeavor to clinical implementation and explore additional clinical indications that may benefit from the unique capabilities of MPI.
Collapse
Affiliation(s)
| | | | - Whitney L Stoppel
- Chemical Engineering, University of Florida, Gainesville FL
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville FL
| | - Carlos M Rinaldi-Ramos
- Chemical Engineering, University of Florida, Gainesville FL
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville FL
| |
Collapse
|
8
|
Rezaei B, Tay ZW, Mostufa S, Manzari ON, Azizi E, Ciannella S, Moni HEJ, Li C, Zeng M, Gómez-Pastora J, Wu K. Magnetic nanoparticles for magnetic particle imaging (MPI): design and applications. NANOSCALE 2024; 16:11802-11824. [PMID: 38809214 DOI: 10.1039/d4nr01195c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2024]
Abstract
Recent advancements in medical imaging have brought forth various techniques such as magnetic resonance imaging (MRI), computed tomography (CT), positron emission tomography (PET), and ultrasound, each contributing to improved diagnostic capabilities. Most recently, magnetic particle imaging (MPI) has become a rapidly advancing imaging modality with profound implications for medical diagnostics and therapeutics. By directly detecting the magnetization response of magnetic tracers, MPI surpasses conventional imaging modalities in sensitivity and quantifiability, particularly in stem cell tracking applications. Herein, this comprehensive review explores the fundamental principles, instrumentation, magnetic nanoparticle tracer design, and applications of MPI, offering insights into recent advancements and future directions. Novel tracer designs, such as zinc-doped iron oxide nanoparticles (Zn-IONPs), exhibit enhanced performance, broadening MPI's utility. Spatial encoding strategies, scanning trajectories, and instrumentation innovations are elucidated, illuminating the technical underpinnings of MPI's evolution. Moreover, integrating machine learning and deep learning methods enhances MPI's image processing capabilities, paving the way for more efficient segmentation, quantification, and reconstruction. The potential of superferromagnetic iron oxide nanoparticle chains (SFMIOs) as new MPI tracers further advanced the imaging quality and expanded clinical applications, underscoring the promising future of this emerging imaging modality.
Collapse
Affiliation(s)
- Bahareh Rezaei
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Zhi Wei Tay
- National Institute of Advanced Industrial Science and Technology (AIST), Health and Medical Research Institute, Tsukuba, Ibaraki 305-8564, Japan
| | - Shahriar Mostufa
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Omid Nejati Manzari
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Ebrahim Azizi
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Stefano Ciannella
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | - Hur-E-Jannat Moni
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | - Changzhi Li
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Minxiang Zeng
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | | | - Kai Wu
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| |
Collapse
|
9
|
Tay Z, Kim HJ, Ho JS, Olivo M. A Magnetic Particle Imaging Approach for Minimally Invasive Imaging and Sensing With Implantable Bioelectronic Circuits. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:1740-1752. [PMID: 38157469 DOI: 10.1109/tmi.2023.3348149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Minimally-invasive and biocompatible implantable bioelectronic circuits are used for long-term monitoring of physiological processes in the body. However, there is a lack of methods that can cheaply and conveniently image the device within the body while simultaneously extracting sensor information. Magnetic Particle Imaging (MPI) with zero background signal, high contrast, and high sensitivity with quantitative images is ideal for this challenge because the magnetic signal is not absorbed with increasing tissue depth and incurs no radiation dose. We show how to easily modify common implantable devices to be imaged by MPI by encapsulating and magnetically-coupling magnetic nanoparticles (SPIOs) to the device circuit. These modified implantable devices not only provide spatial information via MPI, but also couple to our handheld MPI reader to transmit sensor information by modulating harmonic signals from magnetic nanoparticles via switching or frequency-shifting with resistive or capacitive sensors. This paper provides proof-of-concept of an optimized MPI imaging technique for implantable devices to extract spatial information as well as other information transmitted by the implanted circuit (such as biosensing) via encoding in the magnetic particle spectrum. The 4D images present 3D position and a changing color tone in response to a variable biometric. Biophysical sensing via bioelectronic circuits that take advantage of the unique imaging properties of MPI may enable a wide range of minimally invasive applications in biomedicine and diagnosis.
Collapse
|
10
|
Velazquez-Albino AC, Nozka A, Melnyk A, Good HJ, Rinaldi-Ramos CM. Post-synthesis Oxidation of Superparamagnetic Iron Oxide Nanoparticles to Enhance Magnetic Particle Imaging Performance. ACS APPLIED NANO MATERIALS 2024; 7:279-291. [PMID: 38606282 PMCID: PMC11008578 DOI: 10.1021/acsanm.3c04442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/13/2024]
Abstract
This study investigates the impact of post-synthesis oxidation on the performance of superparamagnetic iron oxide nanoparticles (SPIONs) in magnetic particle imaging (MPI), an emerging technology with applications in diagnostic imaging and theranostics. SPIONs synthesized from iron oleate were subjected to a post-synthesis oxidation treatment with a 1% Oxygen in Argon mixture. MPI performance, gauged via signal intensity and resolution using a MOMENTUM™ scanner, was correlated to the nanoparticles' physical and magnetic properties. Post-synthesis oxidation did not alter physical attributes like size and shape, but significantly enhanced magnetic properties. Saturation magnetization increased from 52% to 93% of the bulk value for magnetite, leading to better MPI performance in terms of signal intensity and resolution. However, the observed MPI performance did not fully align with predictions based on the ideal Langevin model, indicating the need for considering factors like relaxation and shape anisotropy. The findings underscore the potential of post-synthesis oxidation as a method to fine-tune magnetic properties of SPIONs and improve MPI performance, and the need for reproducible synthesis methods that afford finely tuned control of nanoparticle size, shape, and magnetic properties.
Collapse
Affiliation(s)
| | - Aniela Nozka
- Department of Bioengineering, Clemson University, Clemson, SC 29634
| | - Andrii Melnyk
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611
| | - Hayden J Good
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611
| | - Carlos M Rinaldi-Ramos
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131
| |
Collapse
|
11
|
Lei S, He J, Gao P, Wang Y, Hui H, An Y, Tian J. Magnetic Particle Imaging-Guided Hyperthermia for Precise Treatment of Cancer: Review, Challenges, and Prospects. Mol Imaging Biol 2023; 25:1020-1033. [PMID: 37789103 DOI: 10.1007/s11307-023-01856-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 09/02/2023] [Accepted: 09/05/2023] [Indexed: 10/05/2023]
Abstract
Magnetic particle imaging (MPI) is a novel quantitative imaging technique using the nonlinear magnetization behavior of magnetic nanoparticles (MNPs) to determine their local concentration. Magnetic fluid hyperthermia (MFH) is a promising non-invasive therapy using the heating effects of MNPs. MPI-MFH is expected to enable real-time MPI guidance, localized MFH, and non-invasive temperature monitoring, which shows great potential for precise treatment of cancer. In this review, we introduce the fundamentals of MPI and MFH and their applications in the treatment of cancer. Also, we discuss the challenges and prospects of MPI-MFH.
Collapse
Affiliation(s)
- Siao Lei
- School of Engineering Medicine & School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
- Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People's Republic of China, Beijing, 100191, People's Republic of China
- CAS Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, China
| | - Jie He
- School of Engineering Medicine & School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
- Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People's Republic of China, Beijing, 100191, People's Republic of China
- CAS Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, China
| | - Pengli Gao
- School of Engineering Medicine & School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
- Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People's Republic of China, Beijing, 100191, People's Republic of China
- CAS Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, China
| | - Yueqi Wang
- CAS Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, China
| | - Hui Hui
- CAS Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, China
| | - Yu An
- School of Engineering Medicine & School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
- Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People's Republic of China, Beijing, 100191, People's Republic of China.
- CAS Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, China.
| | - Jie Tian
- School of Engineering Medicine & School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
- Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People's Republic of China, Beijing, 100191, People's Republic of China.
- CAS Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, China.
- Zhuhai Precision Medical Center, Zhuhai People's Hospital, Affiliated With Jinan University, Zhuhai, 519000, China.
| |
Collapse
|
12
|
Liu S, Heshmat A, Andrew J, Barreto I, Rinaldi-Ramos CM. Dual imaging agent for magnetic particle imaging and computed tomography. NANOSCALE ADVANCES 2023; 5:3018-3032. [PMID: 37260489 PMCID: PMC10228371 DOI: 10.1039/d3na00105a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Accepted: 04/30/2023] [Indexed: 06/02/2023]
Abstract
Magnetic particle imaging (MPI) is a novel biomedical imaging modality that allows non-invasive, tomographic, and quantitative tracking of the distribution of superparamagnetic iron oxide nanoparticle (SPION) tracers. While MPI possesses high sensitivity, detecting nanograms of iron, it does not provide anatomical information. Computed tomography (CT) is a widely used biomedical imaging modality that yields anatomical information at high resolution. A multimodal imaging agent combining the benefits of MPI and CT imaging would be of interest. Here we combine MPI-tailored SPIONs with CT-contrast hafnium oxide (hafnia) nanoparticles using flash nanoprecipitation to obtain dual-imaging MPI/CT agents. Co-encapsulation of iron oxide and hafnia in the composite nanoparticles was confirmed via transmission electron microscopy and elemental mapping. Equilibrium and dynamic magnetic characterization show a reduction in effective magnetic diameter and changes in dynamic magnetic susceptibility spectra at high oscillating field frequencies, suggesting magnetic interactions within the composite dual imaging tracers. The MPI performance of the dual imaging agent was evaluated and compared to the commercial tracer ferucarbotran. The dual-imaging agent has MPI sensitivity that is ∼3× better than this commercial tracer. However, worsening of MPI resolution was observed in the composite tracer when compared to individually coated SPIONs. This worsening resolution could result from magnetic dipolar interactions within the composite dual imaging tracer. The CT performance of the dual imaging agent was evaluated in a pre-clinical animal scanner and a clinical scanner, revealing better contrast compared to a commercial iodine-based contrast agent. We demonstrate that the dual imaging agent can be differentiated from the commercial iodine contrast agent using dual energy CT (DECT) imaging. Furthermore, the dual imaging agent displayed energy-dependent CT contrast arising from the combination of SPION and hafnia, making it potentially suitable for virtual monochromatic imaging of the contrast agent distribution using DECT.
Collapse
Affiliation(s)
- Sitong Liu
- Department of Chemical Engineering, University of Florida Gainesville FL 32611 USA
| | - Anahita Heshmat
- Department of Radiology, University of Florida Gainesville FL 32610-0374 USA
| | - Jennifer Andrew
- Department of Material Science and Engineering, University of Florida Gainesville FL 32603 USA
| | - Izabella Barreto
- Department of Radiology, University of Florida Gainesville FL 32610-0374 USA
| | - Carlos M Rinaldi-Ramos
- Department of Chemical Engineering, University of Florida Gainesville FL 32611 USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida Gainesville FL 32611-6131 USA
| |
Collapse
|
13
|
Doyle O, Bryan J, Kim M, Saayujya C, Nazarian S, Mokkarala-Lopez J, Kuo R, Yousuf M, Chandrasekharan P, Fellows B, Conolly S. Temperature-Dependent Changes in Resolution and Coercivity of Superparamagnetic and Superferromagnetic Iron Oxide Nanoparticles. INTERNATIONAL JOURNAL ON MAGNETIC PARTICLE IMAGING 2023; 9:2303056. [PMID: 39301437 PMCID: PMC11412576 DOI: 10.18416/ijmpi.2023.2303056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Figures] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Magnetic Particle Imaging (MPI) is a tracer-based imaging modality with immense promise as a radiation-free alternative to nuclear medicine imaging techniques. Nuclear medicine requires "hot chemistry" wherein radioactive tracers must be synthesized on-site, requiring expensive infrastructure and labor costs. MPI's magnetic nanoparticles, superparamagnetic iron oxide nanoparticles (SPIOs), have no significant signal decay over time which removes cost barriers associated with nuclear medicine studies such as FDG-PET. While SPIOs are the current industry standard MPI tracer, recent developments in synthesizing superferromagnetic iron oxide nanoparticles (SFMIOs) and high resolution SPIOs (HR-SPIOs), a new class of nanoparticle with almost zero coercivity, have yielded a 30-fold improvement in resolution (0.4 mT) and SNR. To better understand the long-term performance of these new nanoparticles, this investigation reports changes in SPIO (VivoTrax Plus), HR-SPIO, and SFMIO resolution, along with SFMIO coercivity, at low temperatures (-2, 2 °C) and room temperature (18-22 °C) over 12 weeks. We find that changes in HR-SPIO resolution are more sensitive to storage temperature than SFMIOs. Additionally, we observe no appreciable difference in SFMIO coercivity between the two temperatures over time. These results can inform research on optimizing tracer synthesis while lending practical information to future hospitals about the highly accessible conditions for the transit and storage of tracers.
Collapse
Affiliation(s)
- Owen Doyle
- Department of Bioengineering, UC Berkeley, Berkeley CA, USA
| | - Jacob Bryan
- Department of Bioengineering, UC Berkeley, Berkeley CA, USA
- Magnetic Insight, Alameda CA, USA
| | - Melissa Kim
- Department of Bioengineering, UC Berkeley, Berkeley CA, USA
| | - Chinmoy Saayujya
- Department of Electrical Engineering and Computer Sciences, UC Berkeley, Berkeley CA, USA
| | | | | | - Renesmee Kuo
- Department of Bioengineering, UC Berkeley, Berkeley CA, USA
| | - Mariam Yousuf
- Department of Bioengineering, UC Berkeley, Berkeley CA, USA
| | | | - Benjamin Fellows
- Department of Bioengineering, UC Berkeley, Berkeley CA, USA
- Magnetic Insight, Alameda CA, USA
| | - Steven Conolly
- Department of Bioengineering, UC Berkeley, Berkeley CA, USA
- Department of Electrical Engineering and Computer Sciences, UC Berkeley, Berkeley CA, USA
| |
Collapse
|
14
|
Magnetic Particle Imaging in Vascular Imaging, Immunotherapy, Cell Tracking, and Noninvasive Diagnosis. Mol Imaging 2023. [DOI: 10.1155/2023/4131117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023] Open
Abstract
Magnetic particle imaging (MPI) is a new tracer-based imaging modality that is useful in diagnosing various pathophysiology related to the vascular system and for sensitive tracking of cytotherapies. MPI uses nonradioactive and easily assimilated nanometer-sized iron oxide particles as tracers. MPI images the nonlinear Langevin behavior of the iron oxide particles and has allowed for the sensitive detection of iron oxide-labeled therapeutic cells in the body. This review will provide an overview of MPI technology, the tracer, and its use in vascular imaging and cytotherapies using molecular targets.
Collapse
|
15
|
Practical Guidance for Developing Small-Molecule Optical Probes for In Vivo Imaging. Mol Imaging Biol 2023; 25:240-264. [PMID: 36745354 DOI: 10.1007/s11307-023-01800-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 12/31/2022] [Accepted: 01/05/2023] [Indexed: 02/07/2023]
Abstract
The WMIS Education Committee (2019-2022) reached a consensus that white papers on molecular imaging could be beneficial for practitioners of molecular imaging at their early career stages and other scientists who are interested in molecular imaging. With this consensus, the committee plans to publish a series of white papers on topics related to the daily practice of molecular imaging. In this white paper, we aim to provide practical guidance that could be helpful for optical molecular imaging, particularly for small molecule probe development and validation in vitro and in vivo. The focus of this paper is preclinical animal studies with small-molecule optical probes. Near-infrared fluorescence imaging, bioluminescence imaging, chemiluminescence imaging, image-guided surgery, and Cerenkov luminescence imaging are discussed in this white paper.
Collapse
|
16
|
Yang X, Shao G, Zhang Y, Wang W, Qi Y, Han S, Li H. Applications of Magnetic Particle Imaging in Biomedicine: Advancements and Prospects. Front Physiol 2022; 13:898426. [PMID: 35846005 PMCID: PMC9285659 DOI: 10.3389/fphys.2022.898426] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 05/16/2022] [Indexed: 01/09/2023] Open
Abstract
Magnetic particle imaging (MPI) is a novel emerging noninvasive and radiation-free imaging modality that can quantify superparamagnetic iron oxide nanoparticles tracers. The zero endogenous tissue background signal and short image scanning times ensure high spatial and temporal resolution of MPI. In the context of precision medicine, the advantages of MPI provide a new strategy for the integration of the diagnosis and treatment of diseases. In this review, after a brief explanation of the simplified theory and imaging system, we focus on recent advances in the biomedical application of MPI, including vascular structure and perfusion imaging, cancer imaging, the MPI guidance of magnetic fluid hyperthermia, the visual monitoring of cell and drug treatments, and intraoperative navigation. We finally optimize MPI in terms of the system and tracers, and present future potential biomedical applications of MPI.
Collapse
Affiliation(s)
- Xue Yang
- Beijing You’an Hospital, Capital Medical University, Beijing, China
| | | | - Yanyan Zhang
- Beijing You’an Hospital, Capital Medical University, Beijing, China
| | - Wei Wang
- Beijing You’an Hospital, Capital Medical University, Beijing, China
| | - Yu Qi
- Beijing You’an Hospital, Capital Medical University, Beijing, China
| | - Shuai Han
- Beijing You’an Hospital, Capital Medical University, Beijing, China
| | - Hongjun Li
- Beijing You’an Hospital, Capital Medical University, Beijing, China,*Correspondence: Hongjun Li,
| |
Collapse
|
17
|
Advancements in nanomedicines for the detection and treatment of diabetic kidney disease. BIOMATERIALS AND BIOSYSTEMS 2022; 6:100047. [PMID: 36824160 PMCID: PMC9934479 DOI: 10.1016/j.bbiosy.2022.100047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 03/22/2022] [Accepted: 03/27/2022] [Indexed: 12/18/2022] Open
Abstract
In the diabetic kidneys, morbidities such as accelerated ageing, hypertension and hyperglycaemia create a pro-inflammatory microenvironment characterised by extensive fibrogenesis. Radiological techniques are not yet optimised generating inconsistent and non-reproducible data. The gold standard procedure to assess renal fibrosis is kidney biopsy, followed by histopathological assessment. However, this method is risky, invasive, subjective and examines less than 0.01% of kidney tissue resulting in diagnostic errors. As such, less than 10% of patients undergo kidney biopsy, limiting the accuracy of the current diabetic kidney disease (DKD) staging method. Standard treatments suppress the renin-angiotensin system to control hypertension and use of pharmaceuticals aimed at controlling diabetes have shown promise but can cause hypoglycaemia, diuresis and malnutrition as a result of low caloric intake. New approaches to both diagnosis and treatment are required. Nanoparticles (NPs) are an attractive candidate for managing DKD due to their ability to act as theranostic tools that can carry drugs and enhance image contrast. NP-based point-of-care systems can provide physiological information previously considered unattainable and provide control over the rate and location of drug release. Here we discuss the use of nanotechnology in renal disease, its application to both the treatment and diagnosis of DKD. Finally, we propose a new method of NP-based DKD classification that overcomes the current systems limitations.
Collapse
|
18
|
Harvell-Smith S, Tung LD, Thanh NTK. Magnetic particle imaging: tracer development and the biomedical applications of a radiation-free, sensitive, and quantitative imaging modality. NANOSCALE 2022; 14:3658-3697. [PMID: 35080544 DOI: 10.1039/d1nr05670k] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Magnetic particle imaging (MPI) is an emerging tracer-based modality that enables real-time three-dimensional imaging of the non-linear magnetisation produced by superparamagnetic iron oxide nanoparticles (SPIONs), in the presence of an external oscillating magnetic field. As a technique, it produces highly sensitive radiation-free tomographic images with absolute quantitation. Coupled with a high contrast, as well as zero signal attenuation at-depth, there are essentially no limitations to where that can be imaged within the body. These characteristics enable various biomedical applications of clinical interest. In the opening sections of this review, the principles of image generation are introduced, along with a detailed comparison of the fundamental properties of this technique with other common imaging modalities. The main feature is a presentation on the up-to-date literature for the development of SPIONs tailored for improved imaging performance, and developments in the current and promising biomedical applications of this emerging technique, with a specific focus on theranostics, cell tracking and perfusion imaging. Finally, we will discuss recent progress in the clinical translation of MPI. As signal detection in MPI is almost entirely dependent on the properties of the SPION employed, this work emphasises the importance of tailoring the synthetic process to produce SPIONs demonstrating specific properties and how this impacts imaging in particular applications and MPI's overall performance.
Collapse
Affiliation(s)
- Stanley Harvell-Smith
- Biophysics Group, Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK.
- UCL Healthcare Biomagnetic and Nanomaterials Laboratories, University College London, 21 Albemarle Street, London W1S 4BS, UK
| | - Le Duc Tung
- Biophysics Group, Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK.
- UCL Healthcare Biomagnetic and Nanomaterials Laboratories, University College London, 21 Albemarle Street, London W1S 4BS, UK
| | - Nguyen Thi Kim Thanh
- Biophysics Group, Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK.
- UCL Healthcare Biomagnetic and Nanomaterials Laboratories, University College London, 21 Albemarle Street, London W1S 4BS, UK
| |
Collapse
|
19
|
Xiao Z, Zhang L, Colvin VL, Zhang Q, Bao G. Synthesis and Application of Magnetic Nanocrystal Clusters. Ind Eng Chem Res 2022. [DOI: 10.1021/acs.iecr.1c04879] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Zhen Xiao
- Department of Chemistry, Brown University, Providence, Rhode Island 02912, United States
| | - Linlin Zhang
- Department of Bioengineering, Rice University, Houston, Texas 77005, United States
| | - Vicki L. Colvin
- Department of Chemistry, Brown University, Providence, Rhode Island 02912, United States
| | - Qingbo Zhang
- Department of Bioengineering, Rice University, Houston, Texas 77005, United States
| | - Gang Bao
- Department of Bioengineering, Rice University, Houston, Texas 77005, United States
| |
Collapse
|
20
|
Tay ZW, Savliwala S, Hensley DW, Fung KLB, Colson C, Fellows BD, Zhou X, Huynh Q, Lu Y, Zheng B, Chandrasekharan P, Rivera-Jimenez SM, Rinaldi-Ramos CM, Conolly SM. Superferromagnetic Nanoparticles Enable Order-of-Magnitude Resolution & Sensitivity Gain in Magnetic Particle Imaging. SMALL METHODS 2021; 5:e2100796. [PMID: 34927972 PMCID: PMC8837195 DOI: 10.1002/smtd.202100796] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Indexed: 05/02/2023]
Abstract
Magnetic nanoparticles have many advantages in medicine such as their use in non-invasive imaging as a Magnetic Particle Imaging (MPI) tracer or Magnetic Resonance Imaging contrast agent, the ability to be externally shifted or actuated and externally excited to generate heat or release drugs for therapy. Existing nanoparticles have a gentle sigmoidal magnetization response that limits resolution and sensitivity. Here it is shown that superferromagnetic iron oxide nanoparticle chains (SFMIOs) achieve an ideal step-like magnetization response to improve both image resolution & SNR by more than tenfold over conventional MPI. The underlying mechanism relies on dynamic magnetization with square-like hysteresis loops in response to 20 kHz, 15 kAm-1 MPI excitation, with nanoparticles assembling into a chain under an applied magnetic field. Experimental data shows a "1D avalanche" dipole reversal of every nanoparticle in the chain when the applied field overcomes the dynamic coercive threshold of dipole-dipole fields from adjacent nanoparticles in the chain. Intense inductive signal is produced from this event resulting in a sharp signal peak. Novel MPI imaging strategies are demonstrated to harness this behavior towards order-of-magnitude medical image improvements. SFMIOs can provide a breakthrough in noninvasive imaging of cancer, pulmonary embolism, gastrointestinal bleeds, stroke, and inflammation imaging.
Collapse
Affiliation(s)
- Zhi Wei Tay
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
- Institute of Bioengineering and Bioimaging, Agency for Science, Technology and Research (A*STAR), #02-02 Helios Building, Singapore, 138667, Singapore
| | - Shehaab Savliwala
- Department of Chemical Engineering, University of Florida, Gainesville, FL, 32611-6005, USA
| | - Daniel W Hensley
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - K L Barry Fung
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - Caylin Colson
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - Benjamin D Fellows
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - Xinyi Zhou
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - Quincy Huynh
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - Yao Lu
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - Bo Zheng
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | - Prashant Chandrasekharan
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| | | | - Carlos M Rinaldi-Ramos
- Department of Chemical Engineering, University of Florida, Gainesville, FL, 32611-6005, USA
| | - Steven M Conolly
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA, 94720-1762, USA
| |
Collapse
|
21
|
Tay ZW, Chandrasekharan P, Fellows BD, Arrizabalaga IR, Yu E, Olivo M, Conolly SM. Magnetic Particle Imaging: An Emerging Modality with Prospects in Diagnosis, Targeting and Therapy of Cancer. Cancers (Basel) 2021; 13:5285. [PMID: 34771448 PMCID: PMC8582440 DOI: 10.3390/cancers13215285] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 10/15/2021] [Accepted: 10/19/2021] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Magnetic Particle Imaging (MPI) is an emerging imaging modality for quantitative direct imaging of superparamagnetic iron oxide nanoparticles (SPION or SPIO). With different physics from MRI, MPI benefits from ideal image contrast with zero background tissue signal. This enables clear visualization of cancer with image characteristics similar to PET or SPECT, but using radiation-free magnetic nanoparticles instead, with infinite-duration reporter persistence in vivo. MPI for cancer imaging: demonstrated months of quantitative imaging of the cancer-related immune response with in situ SPION-labelling of immune cells (e.g., neutrophils, CAR T-cells). Because MPI suffers absolutely no susceptibility artifacts in the lung, immuno-MPI could soon provide completely noninvasive early-stage diagnosis and treatment monitoring of lung cancers. MPI for magnetic steering: MPI gradients are ~150 × stronger than MRI, enabling remote magnetic steering of magneto-aerosol, nanoparticles, and catheter tips, enhancing therapeutic delivery by magnetic means. MPI for precision therapy: gradients enable focusing of magnetic hyperthermia and magnetic-actuated drug release with up to 2 mm precision. The extent of drug release from the magnetic nanocarrier can be quantitatively monitored by MPI of SPION's MPS spectral changes within the nanocarrier. CONCLUSION MPI is a promising new magnetic modality spanning cancer imaging to guided-therapy.
Collapse
Affiliation(s)
- Zhi Wei Tay
- Institute of Bioengineering and Bioimaging, Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02 Helios Building, Singapore 138667, Singapore;
| | - Prashant Chandrasekharan
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA 94720-1762, USA; (P.C.); (B.D.F.); (I.R.A.); (E.Y.); (S.M.C.)
| | - Benjamin D. Fellows
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA 94720-1762, USA; (P.C.); (B.D.F.); (I.R.A.); (E.Y.); (S.M.C.)
| | - Irati Rodrigo Arrizabalaga
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA 94720-1762, USA; (P.C.); (B.D.F.); (I.R.A.); (E.Y.); (S.M.C.)
| | - Elaine Yu
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA 94720-1762, USA; (P.C.); (B.D.F.); (I.R.A.); (E.Y.); (S.M.C.)
| | - Malini Olivo
- Institute of Bioengineering and Bioimaging, Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02 Helios Building, Singapore 138667, Singapore;
| | - Steven M. Conolly
- Department of Bioengineering, 340 Hearst Memorial Mining Building, University of California Berkeley, Berkeley, CA 94720-1762, USA; (P.C.); (B.D.F.); (I.R.A.); (E.Y.); (S.M.C.)
| |
Collapse
|
22
|
Lu C, Han L, Wang J, Wan J, Song G, Rao J. Engineering of magnetic nanoparticles as magnetic particle imaging tracers. Chem Soc Rev 2021; 50:8102-8146. [PMID: 34047311 DOI: 10.1039/d0cs00260g] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Magnetic particle imaging (MPI) has recently emerged as a promising non-invasive imaging technique because of its signal linearly propotional to the tracer mass, ability to generate positive contrast, low tissue background, unlimited tissue penetration depth, and lack of ionizing radiation. The sensitivity and resolution of MPI are highly dependent on the properties of magnetic nanoparticles (MNPs), and extensive research efforts have been focused on the design and synthesis of tracers. This review examines parameters that dictate the performance of MNPs, including size, shape, composition, surface property, crystallinity, the surrounding environment, and aggregation state to provide guidance for engineering MPI tracers with better performance. Finally, we discuss applications of MPI imaging and its challenges and perspectives in clinical translation.
Collapse
Affiliation(s)
- Chang Lu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China.
| | - Linbo Han
- College of Health Science and Environmental Engineering, Shenzhen Technology University, Shenzhen 518118, P. R. China
| | - Joanna Wang
- Molecular Imaging Program at Stanford, Department of Radiology, Stanford University School of Medicine, 1201 Welch Road, Stanford, California 94305-5484, USA.
| | - Jiacheng Wan
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China.
| | - Guosheng Song
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China.
| | - Jianghong Rao
- Molecular Imaging Program at Stanford, Department of Radiology, Stanford University School of Medicine, 1201 Welch Road, Stanford, California 94305-5484, USA.
| |
Collapse
|
23
|
Rivera-Rodriguez A, Hoang-Minh LB, Chiu-Lam A, Sarna N, Marrero-Morales L, Mitchell DA, Rinaldi-Ramos CM. Tracking adoptive T cell immunotherapy using magnetic particle imaging. Nanotheranostics 2021; 5:431-444. [PMID: 33972919 PMCID: PMC8100755 DOI: 10.7150/ntno.55165] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 04/16/2021] [Indexed: 11/21/2022] Open
Abstract
Adoptive cellular therapy (ACT) is a potent strategy to boost the immune response against cancer. ACT is effective against blood cancers but faces challenges in treating solid tumors. A critical step for the success of ACT immunotherapy is to achieve efficient trafficking and persistence of T cells to solid tumors. Non-invasive tracking of the accumulation of adoptively transferred T cells to tumors would greatly accelerate development of more effective ACT strategies. We demonstrate the use of magnetic particle imaging (MPI) to non-invasively track ACT T cells in vivo in a mouse model of brain cancer. Magnetic labeling did not impair primary tumor-specific T cells in vitro, and MPI allowed the detection of labeled T cells in the brain after intravenous or intracerebroventricular administration. These results support the use of MPI to track adoptively transferred T cells and accelerate the development of ACT treatments for brain tumors and other cancers.
Collapse
Affiliation(s)
- Angelie Rivera-Rodriguez
- J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL USA
| | - Lan B. Hoang-Minh
- Preston A. Wells, Jr. Center for Brain Tumor Therapy, University of Florida, Gainesville, FL USA
- Lillian S. Wells Department of Neurosurgery, McKnight Brain Institute, University of Florida, Gainesville, FL USA
| | - Andreina Chiu-Lam
- Department of Chemical Engineering, University of Florida, Gainesville, FL USA
| | - Nicole Sarna
- J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL USA
| | - Leyda Marrero-Morales
- J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL USA
| | - Duane A. Mitchell
- Preston A. Wells, Jr. Center for Brain Tumor Therapy, University of Florida, Gainesville, FL USA
- Lillian S. Wells Department of Neurosurgery, McKnight Brain Institute, University of Florida, Gainesville, FL USA
- UF Health Cancer Center, University of Florida, Gainesville, FL USA
| | - Carlos M. Rinaldi-Ramos
- J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL USA
- Department of Chemical Engineering, University of Florida, Gainesville, FL USA
- UF Health Cancer Center, University of Florida, Gainesville, FL USA
| |
Collapse
|
24
|
Liu S, Chiu-Lam A, Rivera-Rodriguez A, DeGroff R, Savliwala S, Sarna N, Rinaldi-Ramos CM. Long circulating tracer tailored for magnetic particle imaging. Nanotheranostics 2021; 5:348-361. [PMID: 33850693 PMCID: PMC8040827 DOI: 10.7150/ntno.58548] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 03/02/2021] [Indexed: 12/12/2022] Open
Abstract
Superparamagnetic iron oxide nanoparticle (SPION) tracers possessing long blood circulation time and tailored for magnetic particle imaging (MPI) performance are crucial for the development of this emerging molecular imaging modality. Here, single-core SPION MPI tracers coated with covalently bonded polyethyelene glycol (PEG) brushes were obtained using a semi-batch thermal decomposition synthesis with controlled addition of molecular oxygen, followed by an optimized PEG-silane ligand exchange procedure. The physical and magnetic properties, MPI performance, and blood circulation time of these newly synthesized tracers were compared to those of two commercially available SPIONs that were not tailored for MPI but are used for MPI: ferucarbotran and PEG-coated Synomag®-D. The new tailored tracer has MPI sensitivity that is ~3-times better than the commercial tracer ferucarbotran and much longer circulation half-life than both commercial tracers (t1/2=6.99 h for the new tracer, vs t1/2=0.59 h for ferucarbotran, and t1/2=0.62 h for PEG-coated Synomag®-D).
Collapse
Affiliation(s)
- Sitong Liu
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Andreina Chiu-Lam
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Angelie Rivera-Rodriguez
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131, USA
| | - Ryan DeGroff
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131, USA
| | - Shehaab Savliwala
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Nicole Sarna
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131, USA
| | - Carlos M Rinaldi-Ramos
- Department of Chemical Engineering, University of Florida, Gainesville, FL 32611, USA.,J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131, USA
| |
Collapse
|
25
|
Chandrasekharan P, Fung KB, Zhou XY, Cui W, Colson C, Mai D, Jeffris K, Huynh Q, Saayujya C, Kabuli L, Fellows B, Lu Y, Yu E, Tay ZW, Zheng B, Fong L, Conolly SM. Non-radioactive and sensitive tracking of neutrophils towards inflammation using antibody functionalized magnetic particle imaging tracers. Nanotheranostics 2021; 5:240-255. [PMID: 33614400 PMCID: PMC7893534 DOI: 10.7150/ntno.50721] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Accepted: 01/14/2021] [Indexed: 02/07/2023] Open
Abstract
White blood cells (WBCs) are a key component of the mammalian immune system and play an essential role in surveillance, defense, and adaptation against foreign pathogens. Apart from their roles in the active combat of infection and the development of adaptive immunity, immune cells are also involved in tumor development and metastasis. Antibody-based therapeutics have been developed to regulate (i.e. selectively activate or inhibit immune function) and harness immune cells to fight malignancy. Alternatively, non-invasive tracking of WBC distribution can diagnose inflammation, infection, fevers of unknown origin (FUOs), and cancer. Magnetic Particle Imaging (MPI) is a non-invasive, non-radioactive, and sensitive medical imaging technique that uses safe superparamagnetic iron oxide nanoparticles (SPIOs) as tracers. MPI has previously been shown to track therapeutic stem cells for over 87 days with a ~200 cell detection limit. In the current work, we utilized antibody-conjugated SPIOs specific to neutrophils for in situ labeling, and non-invasive and radiation-free tracking of these inflammatory cells to sites of infection and inflammation in an in vivo murine model of lipopolysaccharide-induced myositis. MPI showed sensitive detection of inflammation with a contrast-to-noise ratio of ~8-13.
Collapse
Affiliation(s)
- Prashant Chandrasekharan
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - K.L. Barry Fung
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
- UC Berkeley-UCSF Graduate Group in Bioengineering, California, United States
| | - Xinyi Y. Zhou
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
- UC Berkeley-UCSF Graduate Group in Bioengineering, California, United States
| | - Weiwen Cui
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Caylin Colson
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
- UC Berkeley-UCSF Graduate Group in Bioengineering, California, United States
| | - David Mai
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Kenneth Jeffris
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Quincy Huynh
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720, United States
| | - Chinmoy Saayujya
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720, United States
| | - Leyla Kabuli
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Benjamin Fellows
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Yao Lu
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Elaine Yu
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Zhi Wei Tay
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Bo Zheng
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Lawrence Fong
- UCSF Helen Diller Family Comprehensive Cancer Center, University of California, San Francisco, California 94143, United States
| | - Steven M. Conolly
- Department of Bioengineering, University of California, Berkeley, California 94720, United States
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720, United States
| |
Collapse
|
26
|
Hildebrand S, Löwa N, Paysen H, Fratila RM, Reverte-Salisa L, Trakoolwilaiwan T, Niu Z, Kasparis G, Preuss SF, Kosch O, M de la Fuente J, Thanh NTK, Wiekhorst F, Pfeifer A. Quantification of Lipoprotein Uptake in Vivo Using Magnetic Particle Imaging and Spectroscopy. ACS NANO 2021; 15:434-446. [PMID: 33306343 DOI: 10.1021/acsnano.0c03229] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Lipids are a major source of energy for most tissues, and lipid uptake and storage is therefore crucial for energy homeostasis. So far, quantification of lipid uptake in vivo has primarily relied on radioactive isotope labeling, exposing human subjects or experimental animals to ionizing radiation. Here, we describe the quantification of in vivo uptake of chylomicrons, the primary carriers of dietary lipids, in metabolically active tissues using magnetic particle imaging (MPI) and magnetic particle spectroscopy (MPS). We show that loading artificial chylomicrons (ACM) with iron oxide nanoparticles (IONPs) enables rapid and highly sensitive post hoc detection of lipid uptake in situ using MPS. Importantly, by utilizing highly magnetic Zn-doped iron oxide nanoparticles (ZnMNPs), we generated ACM with MPI tracer properties superseding the current gold-standard, Resovist, enabling quantification of lipid uptake from whole-animal scans. We focused on brown adipose tissue (BAT), which dissipates heat and can consume a large part of nutrient lipids, as a model for tightly regulated and inducible lipid uptake. High BAT activity in humans correlates with leanness and improved cardiometabolic health. However, the lack of nonradioactive imaging techniques is an important hurdle for the development of BAT-centered therapies for metabolic diseases such as obesity and type 2 diabetes. Comparison of MPI measurements with iron quantification by inductively coupled plasma mass spectrometry revealed that MPI rivals the performance of this highly sensitive technique. Our results represent radioactivity-free quantification of lipid uptake in metabolically active tissues such as BAT.
Collapse
Affiliation(s)
- Staffan Hildebrand
- Institut für Pharmakologie und Toxikologie, Rheinische Friedrich-Wilhelms-Universität Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| | - Norbert Löwa
- 8.23 Metrology for Magnetic Nanoparticles, Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, 10587 Berlin, Germany
| | - Hendrik Paysen
- 8.23 Metrology for Magnetic Nanoparticles, Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, 10587 Berlin, Germany
| | - Raluca M Fratila
- INMA - Instituto de Nanociencia y Materiales de Aragón (INMA), CSIC-Universidad de Zaragoza, 50009 Zaragoza, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain
| | - Laia Reverte-Salisa
- Institut für Pharmakologie und Toxikologie, Rheinische Friedrich-Wilhelms-Universität Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| | - Thithawat Trakoolwilaiwan
- Biophysics Group, Department of Physics and Astronomy, University College London, London WC1E 6BT, U.K
- UCL Healthcare Biomagnetics Laboratories, 21 Albemarle Street, London W1S 4BS, U.K
| | - Zheming Niu
- Institut für Pharmakologie und Toxikologie, Rheinische Friedrich-Wilhelms-Universität Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| | - Georgios Kasparis
- Biophysics Group, Department of Physics and Astronomy, University College London, London WC1E 6BT, U.K
- UCL Healthcare Biomagnetics Laboratories, 21 Albemarle Street, London W1S 4BS, U.K
| | - Stephanie Franziska Preuss
- Institut für Pharmakologie und Toxikologie, Rheinische Friedrich-Wilhelms-Universität Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| | - Olaf Kosch
- 8.23 Metrology for Magnetic Nanoparticles, Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, 10587 Berlin, Germany
| | - Jesus M de la Fuente
- INMA - Instituto de Nanociencia y Materiales de Aragón (INMA), CSIC-Universidad de Zaragoza, 50009 Zaragoza, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain
| | - Nguyen Thi Kim Thanh
- Biophysics Group, Department of Physics and Astronomy, University College London, London WC1E 6BT, U.K
- UCL Healthcare Biomagnetics Laboratories, 21 Albemarle Street, London W1S 4BS, U.K
| | - Frank Wiekhorst
- 8.23 Metrology for Magnetic Nanoparticles, Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, 10587 Berlin, Germany
| | - Alexander Pfeifer
- Institut für Pharmakologie und Toxikologie, Rheinische Friedrich-Wilhelms-Universität Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
| |
Collapse
|
27
|
Lu Y, Rivera-Rodriguez A, Tay ZW, Hensley D, Fung KLB, Colson C, Saayujya C, Huynh Q, Kabuli L, Fellows B, Chandrasekharan P, Rinaldi C, Conolly S. Combining magnetic particle imaging and magnetic fluid hyperthermia for localized and image-guided treatment. Int J Hyperthermia 2021; 37:141-154. [PMID: 33426994 DOI: 10.1080/02656736.2020.1853252] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Magnetic fluid hyperthermia (MFH) has been widely investigated as a treatment tool for cancer and other diseases. However, focusing traditional MFH to a tumor deep in the body is not feasible because the in vivo wavelength of 300 kHz very low frequency (VLF) excitation fields is longer than 100 m. Recently we demonstrated that millimeter-precision localized heating can be achieved by combining magnetic particle imaging (MPI) with MFH. In principle, real-time MPI imaging can also guide the location and dosing of MFH treatments. Hence, the combination of MPI imaging plus real time localized MPI-MFH could soon permit closed-loop high-resolution hyperthermia treatment. In this review, we will discuss the fundamentals of localized MFH (e.g. physics and biosafety limitations), hardware implementation, MPI real-time guidance, and new research directions on MPI-MFH. We will also discuss how the scale up to human-sized MPI-MFH scanners could proceed.
Collapse
Affiliation(s)
- Yao Lu
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | - Angelie Rivera-Rodriguez
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Zhi Wei Tay
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | | | - K L Barry Fung
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | - Caylin Colson
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | - Chinmoy Saayujya
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| | - Quincy Huynh
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| | - Leyla Kabuli
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| | - Benjamin Fellows
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | | | - Carlos Rinaldi
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA.,Department of Chemical Engineering, University of Florida, Gainesville, FL, USA
| | - Steven Conolly
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA.,Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| |
Collapse
|
28
|
Chandrasekharan P, Tay ZW, Zhou XY, Yu EY, Fung BK, Colson C, Fellows BD, Lu Y, Huynh Q, Saayujya C, Keselman P, Hensley D, Lu K, Orendorff R, Konkle J, Saritas EU, Zheng B, Goodwill P, Conolly S. Magnetic Particle Imaging for Vascular, Cellular and Molecular Imaging. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00015-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
29
|
Abstract
Many labs have been developing cellular magnetic resonance imaging (MRI), using both superparamagnetic iron oxide nanoparticles (SPIONs) and fluorine-19 (19F)-based cell labels, to track immune and stem cells used for cellular therapies. Although SPION-based MRI cell tracking has very high sensitivity for cell detection, SPIONs are indirectly detected owing to relaxation effects on protons, producing negative magnetic resonance contrast with low signal specificity. Therefore, it is not possible to reliably quantify the local tissue concentration of SPION particles, and cell number cannot be determined. 19F-based cell tracking has high specificity for perfluorocarbon-labeled cells, and 19F signal is directly related to cell number. However, 19F MRI has low sensitivity. Magnetic particle imaging (MPI) is a new imaging modality that directly detects SPIONs. SPION-based cell tracking using MPI displays great potential for overcoming the challenges of MRI-based cell tracking, allowing for both high cellular sensitivity and specificity, and quantification of SPION-labeled cell number. Here we describe nanoparticle and MPI system factors that influence MPI sensitivity and resolution, quantification methods, and give our perspective on testing and applying MPI for cell tracking.
Collapse
Affiliation(s)
- Olivia C. Sehl
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Julia J. Gevaert
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Kierstin P. Melo
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Natasha N. Knier
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | - Paula J. Foster
- Imaging Research Laboratories, Robarts Research Institute; and
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| |
Collapse
|
30
|
Sjöstrand S, Evertsson M, Jansson T. Magnetomotive Ultrasound Imaging Systems: Basic Principles and First Applications. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2636-2650. [PMID: 32753288 DOI: 10.1016/j.ultrasmedbio.2020.06.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 04/29/2020] [Accepted: 06/19/2020] [Indexed: 06/11/2023]
Abstract
This review discusses magnetomotive ultrasound, which is an emerging technique that uses superparamagnetic iron oxide nanoparticles as a contrast agent. The key advantage of using nanoparticle-based contrast agents is their ability to reach extravascular targets, whereas commercial contrast agents for ultrasound comprise microbubbles confined to the blood stream. This also extends possibilities for molecular imaging, where the contrast agent is labeled with specific targeting molecules (e.g., antibodies) so that pathologic tissue may be visualized directly. The principle of action is that an external time-varying magnetic field acts to displace the nanoparticles lodged in tissue and thereby their immediate surrounding. This movement is then detected with ultrasound using frequency- or time-domain analysis of echo data. As a contrast agent already approved for magnetic resonance imaging (MRI) by the US Food and Drug Administration, there is a shorter path to clinical translation, although safety studies of magnetomotion are necessary, especially if particle design is altered to affect biodistribution or signal strength. The external modulated magnetic field may be generated by electromagnets, permanent magnets, or a combination of the two. The induced nanoparticle motion may also reveal mechanical material properties of tissue, healthy or diseased, one of several interesting potential future aspects of the technique.
Collapse
Affiliation(s)
- Sandra Sjöstrand
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Maria Evertsson
- Department of Clinical Sciences Lund/Biomedical Engineering, Lund University, Lund, Sweden
| | - Tomas Jansson
- Department of Clinical Sciences Lund/Biomedical Engineering, Lund University, Lund, Sweden; Clinical Engineering Skåne, Digitalisering IT/MT, Region Skåne, Lund, Sweden.
| |
Collapse
|
31
|
Guzy J, Chakravarty S, Buchanan FJ, Chen H, Gaudet JM, Hix JM, Mallett CL, Shapiro EM. Complex Relationship Between Iron Oxide Nanoparticle Degradation and Signal Intensity in Magnetic Particle Imaging. ACS APPLIED NANO MATERIALS 2020; 3:3991-3999. [PMID: 33163909 PMCID: PMC7643918 DOI: 10.1021/acsanm.0c00779] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Magnetic particle imaging (MPI), using superparamagnetic nanoparticles as an imaging tracer, is touted as a quantitative biomedical imaging technology, but MPI signal properties have never been characterized for magnetic nanoparticles undergoing biodegradation. We show that MPI signal properties can increase or decrease as iron oxide nanoparticles degrade, depending on the nanoparticle formulation and nanocrystal size, and degradation rate and mechanism. Further, we show that long-term in vitro MPI experiments only roughly approximate long-term in vivo MPI signal properties. Further, we demonstrate for the first time, an environmentally sensitive MPI contrast mechanism opening the door to smart contrast paradigms in MPI.
Collapse
Affiliation(s)
- Julia Guzy
- Department of Radiology and Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Shatadru Chakravarty
- Department of Radiology and Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Foster J. Buchanan
- Department of Radiology and Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Haoran Chen
- Department of Radiology and Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Jeffrey M. Gaudet
- Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
- Magnetic Insight, Alameda, CA 94501, USA
| | - Jeremy M.L. Hix
- Department of Radiology and Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Christiane L. Mallett
- Department of Radiology and Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Erik M. Shapiro
- Department of Radiology and Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
- Correspondence should be addressed to: Erik M. Shapiro, MSU Radiology, 846 Service Rd, East Lansing, MI 48824, , Phone: 517-884-3270, Fax: 517-432-2849
| |
Collapse
|
32
|
Salamon J, Dieckhoff J, Kaul MG, Jung C, Adam G, Möddel M, Knopp T, Draack S, Ludwig F, Ittrich H. Visualization of spatial and temporal temperature distributions with magnetic particle imaging for liver tumor ablation therapy. Sci Rep 2020; 10:7480. [PMID: 32366912 PMCID: PMC7198551 DOI: 10.1038/s41598-020-64280-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 04/09/2020] [Indexed: 11/09/2022] Open
Abstract
Temperature-resolved magnetic particle imaging (MPI) represents a promising tool for medical imaging applications. In this study an approach based on a single calibration measurement was applied for highlighting the potential of MPI for monitoring of temperatures during thermal ablation of liver tumors. For this purpose, liver tissue and liver tumor phantoms embedding different superparamagnetic iron oxide nanoparticles (SPION) were prepared, locally heated up to 70 °C and recorded with MPI. Optimal temperature MPI SPIONs and a corresponding linear model for temperature calculation were determined. The temporal and spatial temperature distributions were compared with infrared (IR) camera results yielding quantitative agreements with a mean absolute deviation of 1 °C despite mismatches in boundary areas.
Collapse
Affiliation(s)
- J Salamon
- Department for Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany.
| | - J Dieckhoff
- Department for Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - M G Kaul
- Department for Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - C Jung
- Department for Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - G Adam
- Department for Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| | - M Möddel
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany.,Institute for Biomedical Imaging, Hamburg University of Technology, 21073, Hamburg, Germany
| | - T Knopp
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany.,Institute for Biomedical Imaging, Hamburg University of Technology, 21073, Hamburg, Germany
| | - S Draack
- Institute of Electrical Measurement Science and Fundamental Electrical Engineering, TU Braunschweig, 38106, Braunschweig, Germany
| | - F Ludwig
- Institute of Electrical Measurement Science and Fundamental Electrical Engineering, TU Braunschweig, 38106, Braunschweig, Germany
| | - H Ittrich
- Department for Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20246, Hamburg, Germany
| |
Collapse
|
33
|
Tay ZW, Hensley DW, Chandrasekharan P, Zheng B, Conolly SM. Optimization of Drive Parameters for Resolution, Sensitivity and Safety in Magnetic Particle Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:1724-1734. [PMID: 31796392 PMCID: PMC8034762 DOI: 10.1109/tmi.2019.2957041] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Magnetic Particle Imaging is an emerging tracer imaging modality with zero background signal and zero ionizing radiation, high contrast and high sensitivity with quantitative images. While there is recent work showing that the low amplitude or low frequency drive parameters can improve MPI's spatial resolution by mitigating relaxation losses, the concomitant decrease of the MPI's tracer sensitivity due to the lower drive slew rates was not fully addressed. There has yet to be a wide parameter space, multi-objective optimization of MPI drive parameters for high resolution, high sensitivity and safety. In a large-scale study, we experimentally test 5 different nanoparticles ranging from multi to single-core across 18.5 nm to 32.1 nm core sizes and across an expansive drive parameter range of 0.4 - 416 kHz and 0.5 - 40 mT/ μ0 to assess spatial resolution, SNR, and safety. In addition, we analyze how drive-parameter-dependent shifts in harmonic signal energy away and towards the discarded first harmonic affect effective SNR in this optimization study. The results show that when optimizing for all four factors of resolution, SNR, discarded-harmonic-energy and safety, the overall trends are no longer monotonic and clear optimal points emerge. We present drive parameters different from conventional preclinical MPI showing ~ 2-fold improvement in spatial resolution while remaining within safety limits and addressing sensitivity by minimizing the typical SNR loss involved. Finally, validation of the optimization results with 2D images of phantoms was performed.
Collapse
|
34
|
Chandrasekharan P, Tay ZW, Hensley D, Zhou XY, Fung BKL, Colson C, Lu Y, Fellows BD, Huynh Q, Saayujya C, Yu E, Orendorff R, Zheng B, Goodwill P, Rinaldi C, Conolly S. Using magnetic particle imaging systems to localize and guide magnetic hyperthermia treatment: tracers, hardware, and future medical applications. Am J Cancer Res 2020; 10:2965-2981. [PMID: 32194849 PMCID: PMC7053197 DOI: 10.7150/thno.40858] [Citation(s) in RCA: 93] [Impact Index Per Article: 18.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 01/27/2020] [Indexed: 01/07/2023] Open
Abstract
Magnetic fluid hyperthermia (MFH) treatment makes use of a suspension of superparamagnetic iron oxide nanoparticles, administered systemically or locally, in combination with an externally applied alternating magnetic field, to ablate target tissue by generating heat through a process called induction. The heat generated above the mammalian euthermic temperature of 37°C induces apoptotic cell death and/or enhances the susceptibility of the target tissue to other therapies such as radiation and chemotherapy. While most hyperthermia techniques currently in development are targeted towards cancer treatment, hyperthermia is also used to treat restenosis, to remove plaques, to ablate nerves and to alleviate pain by increasing regional blood flow. While RF hyperthermia can be directed invasively towards the site of treatment, non-invasive localization of heat through induction is challenging. In this review, we discuss recent progress in the field of RF magnetic fluid hyperthermia and introduce a new diagnostic imaging modality called magnetic particle imaging that allows for a focused theranostic approach encompassing treatment planning, treatment monitoring and spatially localized inductive heating.
Collapse
Affiliation(s)
- Prashant Chandrasekharan
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States,✉ Corresponding author: E-mail: ; Phone: +1 (510) 642 3420
| | - Zhi Wei Tay
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States
| | - Daniel Hensley
- Magnetic Insight, Inc., Alameda, CA 94501, United States
| | - Xinyi Y Zhou
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States
| | - Barry KL Fung
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States
| | - Caylin Colson
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States
| | - Yao Lu
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States
| | - Benjamin D Fellows
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States
| | - Quincy Huynh
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, United States
| | - Chinmoy Saayujya
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, United States
| | - Elaine Yu
- Magnetic Insight, Inc., Alameda, CA 94501, United States
| | - Ryan Orendorff
- Magnetic Insight, Inc., Alameda, CA 94501, United States
| | - Bo Zheng
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States
| | | | - Carlos Rinaldi
- University of Florida, J. Crayton Pruitt Family Department of Biomedical Engineering and Department of Chemical Engineering, FL, 32611 United States
| | - Steven Conolly
- University of California Berkeley, Department of Bioengineering, Berkeley, CA 94720, United States,Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, United States
| |
Collapse
|
35
|
Murase K. Simultaneous correction of sensitivity and spatial resolution in projection-based magnetic particle imaging. Med Phys 2020; 47:1845-1859. [PMID: 32003025 DOI: 10.1002/mp.14056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 01/17/2020] [Accepted: 01/21/2020] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The purpose of this study was to develop a method to simultaneously correct the spatial resolution and inhomogeneous sensitivity of a receiving coil in projection-based magnetic particle imaging - and to investigate its efficacy through simulation and experimental studies. METHODS Magnetic particle imaging (MPI) images were reconstructed using the simultaneous algebraic reconstruction technique (SART), and simultaneous corrections to sensitivity and spatial resolution were performed by incorporating the sensitivity map of the receiving coil and the system function into the SART algorithm. After each SART update, the regularization method - with total variation (TV) minimization - was used to suppress noise amplification and artifact generation. For comparison, MPI images were also reconstructed using the filtered backprojection (FBP) method and the FBP-truncated singular value decomposition (TSVD) method, in which the system function was deconvolved from the projection data using TSVD. In simulation studies, the sensitivity map of a second-order, gradiometer-type receiving coil was generated using the Biot-Savart law, while the system function was obtained by calculating the MPI signals induced by magnetic nanoparticles at various distances from a field-free line (FFL), using a lock-in-amplifier model. The effects of a regularization parameter for TV minimization (α), number of iterations (N), and signal-to-noise ratio (SNR) of the MPI signals on the reconstructed MPI images of a numerical phantom were evaluated, using the image profiles and percent root mean square error (PRMSE). Experimental studies involved the calculation of the system function using a tube phantom. Projection data for an A-shaped phantom were acquired using our MPI scanner, and their MPI images were reconstructed from the projection data, as described above. RESULTS When both the sensitivity and spatial resolution were corrected (SART-SR), the quality of the reconstructed images was seen to have improved, compared to when the spatial resolution was not corrected - or when the FBP and FBP-TSVD methods were used. When SNR was low (20), a larger α value yielded a better image. The minimum PRMSE occurred at N ≈ 200-400 and increased with increasing N thereafter. When SNR was high (100), the image quality was generally not dependent on the α value within its studied range. The PRMSE decreased slowly with increasing N, and tended to converge to a constant value. The full width at half maximum (FWHM) of the profile was obtained from the A-shaped phantom, reconstructed using the SART-SR algorithm with α = 0.05 and N = 1000. The FWHM value of the tube (2 mm diameter) in the A-shaped phantom image was found to be 2.2 mm on average, whereas those calculated from the images obtained by the FBP and FBP-TSVD methods were 4.4 and 3.0 mm on average, respectively. Spatial resolution improved when using the FBP-TSVD method as compared to the FBP method but image distortion and artifacts were observed. CONCLUSIONS Although further studies are necessary to optimize the parameters used in the SART algorithm and in TV minimization, the present results suggest that the proposed method is useful for improving the image quality of projection-based MPI.
Collapse
Affiliation(s)
- Kenya Murase
- Department of Medical Physics and Engineering, Faculty of Health Science, Graduate School of Medicine, Osaka University, Suita, Osaka, 565-0871, Japan.,Center for Borderless Design of Medicine, Graduate School of Medicine, Osaka University, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
36
|
Zhu X, Li J, Peng P, Hosseini Nassab N, Smith BR. Quantitative Drug Release Monitoring in Tumors of Living Subjects by Magnetic Particle Imaging Nanocomposite. NANO LETTERS 2019; 19:6725-6733. [PMID: 31498999 DOI: 10.1021/acs.nanolett.9b01202] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In vivo drug release monitoring provides accurate and reliable information to guide drug dosing. Image-based strategies for in vivo monitoring are advantageous because they are non-invasive and provide visualization of the spatial distribution of drug, but those imaging modalities in use (e.g., fluorescence imaging (FI) and magnetic resonance imaging (MRI)) remain inadequate because of the low tissue penetration depth (for FI) or difficulty with quantification of release rate and signal convolution with noise sources (for MRI). Magnetic particle imaging (MPI), employing superparamagnetic nanoparticles as the contrast agent and sole signal source, enables large tissue penetration and quantifiable signal intensity. These properties make it ideal for application to in vivo drug release monitoring. In this work, we design a superparamagnetic Fe3O4 nanocluster@poly(lactide-co-glycolide acid) core-shell nanocomposite loaded with a chemotherapy drug (doxorubicin) which serves as a dual drug delivery system and MPI quantification tracer. The as-prepared nanocomposite can degrade under a mild acidic microenvironment (pH = 6.5), which induces a sustained release of doxorubicin and gradual decomposition of the Fe3O4 nanocluster, causing the MPI signal changes. We showed that nanocomposite-induced MPI signal changes display a linear correlation with the release rate of doxorubicin over time (R2 = 0.99). Utilizing this phenomenon, we successfully established quantitative monitoring of the release process in cell culture. We then performed in vivo drug release monitoring in a cancer therapy setting using a murine breast cancer model by injecting the nanocomposite, monitoring the drug release, and assessing the induced tumor cell kill. This study provides an improved solution for in vivo drug release monitoring compared to other available monitoring strategies. This translational strategy using a biocompatible polymer-coated iron oxide nanocomposite will be promising in future clinical use.
Collapse
Affiliation(s)
- Xingjun Zhu
- Department of Radiology , Stanford University School of Medicine , Stanford , California 94305 , United States
| | - Jianfeng Li
- Department of Orthopaedic Surgery , Stanford University , Stanford , California 94305 , United States
| | - Peng Peng
- Department of Radiology , Stanford University School of Medicine , Stanford , California 94305 , United States
| | - Niloufar Hosseini Nassab
- Department of Radiology , Stanford University School of Medicine , Stanford , California 94305 , United States
| | - Bryan Ronain Smith
- Department of Radiology , Stanford University School of Medicine , Stanford , California 94305 , United States
- Department of Biomedical Engineering , Michigan State University , East Lansing , Michigan 48823 , United States
| |
Collapse
|
37
|
Tay ZW, Hensley D, Ma J, Chandrasekharan P, Zheng B, Goodwill P, Conolly S. Pulsed Excitation in Magnetic Particle Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:2389-2399. [PMID: 30762537 PMCID: PMC6689437 DOI: 10.1109/tmi.2019.2898202] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Magnetic particle imaging (MPI) is a promising new tracer-based imaging modality. The steady-state, nonlinear magnetization physics most fundamental to MPI typically predicts improving resolution with increasing tracer magnetic core size. For larger tracers, and given typical excitation slew rates, this steady-state prediction is compromised by dynamic processes that induce a significant secondary blur and prevent us from achieving high resolution using larger tracers. Here, we propose a new method of excitation and signal encoding in MPI we call pulsed MPI to overcome this phenomenon. Pulsed MPI allows us to directly encode the steady-state magnetic physics into the time-domain signal. This in turn gives rise to a simple reconstruction algorithm to obtain images free of secondary relaxation-induced blur. Here, we provide a detailed description of our approach in 1D, discuss how it compares with alternative approaches, and show experimental data demonstrating better than 500- [Formula: see text] resolution (at 7 T/m) with large tracers. Finally, we show experimental images from a 2D implementation.
Collapse
|