1
|
Fogante M, Esposto Pirani P, Cela F, Alfonsi J, Tagliati C, Balardi L, Argalia G, Di Eusanio M, Schicchi N. Computed Tomography Imaging of Thoracic Aortic Surgery: Distinguishing Life-Saving Repairs from Life-Threatening Complications. J Imaging 2025; 11:119. [PMID: 40278035 PMCID: PMC12028058 DOI: 10.3390/jimaging11040119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2025] [Revised: 04/12/2025] [Accepted: 04/16/2025] [Indexed: 04/26/2025] Open
Abstract
Thoracic aortic pathology encompasses a spectrum of life-threatening conditions that demand prompt diagnosis and intervention. Significant advancements in surgical management, including open repair, endovascular aortic repair, and hybrid techniques, have markedly enhanced patient outcomes. However, these procedures necessitate meticulous imaging follow-up to identify potential complications. Computed tomography angiography remains the gold standard for evaluating aortic pathology, guiding surgical planning, and monitoring postoperative changes. A thorough understanding of the characteristic imaging features associated with various aortic surgical techniques is crucial for precise assessment, enhancing postoperative surveillance, and optimizing patient management. Distinguishing between surgical complications and postoperative findings is vital to prevent misdiagnosis. This review examines the imaging characteristics of thoracic aortic diseases and their corresponding surgical interventions, emphasizing the differentiation between expected postoperative findings and true pathological conditions. This approach aims to facilitate accurate diagnosis and effective management of complications, ultimately improving patient care.
Collapse
Affiliation(s)
- Marco Fogante
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.); (N.S.)
| | - Paolo Esposto Pirani
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.); (N.S.)
| | - Fatjon Cela
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.); (N.S.)
| | - Jacopo Alfonsi
- Cardiac Surgery Unit, Department of Cardiovascular Sciences, University Hospital of Marche, 60126 Ancona, Italy; (J.A.); (M.D.E.)
| | - Corrado Tagliati
- Ospedale di Comunità Maria Montessori di Chiaravalle, AST Ancona, 60033 Chiaravalle, Italy;
| | - Liliana Balardi
- Health Professions Area, Diagnostic Technical Area, University Hospital of Marche, 60126 Ancona, Italy;
| | - Giulio Argalia
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.); (N.S.)
| | - Marco Di Eusanio
- Cardiac Surgery Unit, Department of Cardiovascular Sciences, University Hospital of Marche, 60126 Ancona, Italy; (J.A.); (M.D.E.)
| | - Nicolò Schicchi
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.); (N.S.)
- Cardiovascular Radiological Diagnostics, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy
| |
Collapse
|
2
|
Gadsbøll EL, Aurumskjöld ML, Holmquist F, Baubeta E. Virtual non-contrast images in photon-counting computed tomography: impact of different contrast phases. Acta Radiol 2024; 65:1147-1152. [PMID: 39140849 DOI: 10.1177/02841851241271202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2024]
Abstract
BACKGROUND Photon-counting computed tomography (PCCT) enables new ways of image reconstruction, e.g. material decomposition and creation of virtual non-contrast (VNC) series with higher resolution and lower radiation dose than standard computed tomography (CT). Clinical experiences of this are limited. PURPOSE To compare true non-contrast (TNC) series with VNC series derived from non-enhanced (VNCu), arterial phase (VNCa) and portal venous phase (VNCv) in clinically approved PCCT. MATERIAL AND METHODS A total of 45 clinical, tri-phasic abdominal CT scans from the PCCT Naetom Alpha, between February 2022 and November 2022, were retrospectively assessed. Placing a region of interest in six different locations in each VNC series - right liver parenchyma, left liver parenchyma, spleen, aorta, erector spinae muscle, and in the subcutaneous fat - absolute Hounsfield values (HU) and standard deviations (SD) were collected. Differences in HU (ΔHU) were compared and statistically analyzed. RESULTS Statistically significant differences between VNC and TNC were seen in all measurements, with the largest difference in the subcutaneous fat and the smallest difference in the erector spinae muscle. Only small differences were seen between VNCa and VNCv, where the largest differences were seen in the left and right liver lobes. CONCLUSION VNC images from the first-generation clinically approved PCCT showed a significant difference between VNC and TNC images. The differences vary with the type of tissue. Only small differences were seen depending from which contrast phase the VNC was derived.
Collapse
Affiliation(s)
- Eva Laurin Gadsbøll
- Department of Imaging and Functional Medicine, Skåne University Hospital, Lund, Sweden
| | - Marie-Louise Aurumskjöld
- Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden
- Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Fredrik Holmquist
- Department of Imaging and Functional Medicine, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Diagnostic Radiology, Lund University, Lund, Sweden
| | - Erik Baubeta
- Department of Imaging and Functional Medicine, Skåne University Hospital, Lund, Sweden
- Department of Translational Medicine, Diagnostic Radiology, Lund University, Malmö, Sweden
| |
Collapse
|
3
|
Wen D, Pu Q, Peng P, Yue X, Ming Y, Yang H, Yang J, Zhang X, Liu H, Yang L, Sun J. Comparison of virtual and true non-contrast images from dual-layer spectral detector computed tomography (CT) in patients with colorectal cancer. Quant Imaging Med Surg 2024; 14:6260-6272. [PMID: 39281124 PMCID: PMC11400675 DOI: 10.21037/qims-24-535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Accepted: 08/05/2024] [Indexed: 09/18/2024]
Abstract
Background Colorectal cancer (CRC) is commonly assessed by computed tomography (CT), but the associated radiation exposure is a major concern. This study aimed to quantitatively and qualitatively compare the image quality of virtual non-contrast (VNC) images reconstructed from arterial and portal venous phases with that of true non-contrast (TNC) images in patients with CRC to assess the potential of TNC images to replace VNC images, thereby reducing the radiation dose. Methods A total of 69 patients with postoperative pathologically confirmed CRC at the West China Hospital of Sichuan University between May 2022 and April 2023 were enrolled in this cross-sectional study. The CT protocol included the acquisition of TNC images, arterial and portal venous phase images; the VNC images were reconstructed from the two postcontrast phase images. Several parameters, including the CT attenuation value, absolute attenuation error, imaging noise [standard deviation (SD)], signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR), were measured in multiple abdominal structures for both the TNC and VNC images. Two blinded readers assessed the subjective image quality using a five-point scale. Interobserver agreement was evaluated using interclass correlation coefficients (ICCs). The paired t-test and Wilcoxon signed-rank test were used to compare the objective and subjective results between the TNC and VNC images. Individual measurements of radiation doses for the TNC scan and contrast scan protocols were recorded. Results A total of 2,070 regions of interest (ROIs) of the 69 patients were analyzed. Overall, the VNC images exhibited significantly lower attenuation values and SD values than the TNC images in all tissues, except for the abdominal aorta, portal vein, and spleen. The mean absolute attenuation errors between the VNC and TNC images were all less than 10 Hounsfield units (HU). The percentages of absolute attenuation errors less than 5 and 10 HU in the VNC images from the arterial phase (VNCa) were 78.99% and 97.97%, respectively, while those from the portal venous phase (VNCp) were 81.59% and 96.96%, respectively. The absolute attenuation errors between the TNC and VNCa images were smaller than those between the TNC and VNCp images for tumors [VNCaerror: 2.77, interquartile range (IQR) 1.77-4.22; VNCperror: 3.27, IQR 2.68-4.30; P=0.002]. The SNR values and CNR values in the VNC images were significantly higher than those in the TNC images for all tissues, except for the portal vein and spleen. The image quality was rated as excellent (represented by a score of 5) in the majority of the TNC and VNC images; however, the VNC images scored lower than the TNC images. Eliminating the TNC phase resulted in a reduction of approximately 37.99% in the effective dose (ED). Conclusions The VNC images provided accurate CT attenuation, good image quality, and lower radiation doses than the TNC images in CRC, and the VNCa images showed minimal differences in the CT attenuation of the tumors.
Collapse
Affiliation(s)
- Deying Wen
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qian Pu
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Pengfei Peng
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Xun Yue
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
- Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Yue Ming
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Huiyi Yang
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Jianyang Yang
- Division of Gastrointestinal Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Xiaodi Zhang
- Clinical Science, Philips Healthcare, Chengdu, China
| | - Haiwei Liu
- Advanced Clinical Application, Philips Healthcare, Beijing, China
| | - Lie Yang
- Division of Gastrointestinal Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Jiayu Sun
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
4
|
Haag F, Emmrich SS, Hertel A, Rink JS, Nörenberg D, Schoenberg SO, Froelich MF. Virtual Non-Contrast versus True Native in Photon-Counting CT: Stability of Density of Upper Abdominal Organs and Vessels. Diagnostics (Basel) 2024; 14:1130. [PMID: 38893656 PMCID: PMC11171968 DOI: 10.3390/diagnostics14111130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 05/10/2024] [Accepted: 05/20/2024] [Indexed: 06/21/2024] Open
Abstract
The clinical use of photon-counting CT (PCCT) allows for the generation of virtual non-contrast (VNC) series from contrast-enhanced images. In routine clinical practice, specific issues such as ruling out acute bleeding require non-contrast images. The aim of this study is to evaluate the use of PCCT-derived VNC reconstructions in abdominal imaging. PCCT scans of 17 patients including early arterial, portal venous and native sequences were enrolled. VNC reconstructions have been calculated. In every sequence and VNC reconstruction, 10 ROIs were measured (portal vein, descending aorta, inferior vena cava, liver parenchyma, spleen parenchyma, erector spinae muscle, subcutaneous adipose tissue, first lumbar vertebral body, air, and psoas muscle) and density values were compared. The VNC reconstructions show significant changes in density compared to the contrast-enhanced images. However, there were no significant differences present between the true non-contrast (TNC) and any VNC reconstructions in the observed organs and vessels. Significant differences (p < 0.05) between the measured mean density values in the TNC versus VNC reconstructions were found in fat and bone tissue. The PCCT-derived VNC reconstructions seemed to be comparable to the TNC images, despite some deviations shown in the adipose tissue and bone structures. However, the further benefits in terms of specific clinical issues need to be evaluated.
Collapse
Affiliation(s)
- Florian Haag
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1–3, 68167 Mannheim, Germany
| | | | | | | | | | | | | |
Collapse
|
5
|
Foti G, Ascenti G, Agostini A, Longo C, Lombardo F, Inno A, Modena A, Gori S. Dual-Energy CT in Oncologic Imaging. Tomography 2024; 10:299-319. [PMID: 38535766 PMCID: PMC10975567 DOI: 10.3390/tomography10030024] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 02/13/2024] [Accepted: 02/22/2024] [Indexed: 08/25/2024] Open
Abstract
Dual-energy CT (DECT) is an innovative technology that is increasingly widespread in clinical practice. DECT allows for tissue characterization beyond that of conventional CT as imaging is performed using different energy spectra that can help differentiate tissues based on their specific attenuation properties at different X-ray energies. The most employed post-processing applications of DECT include virtual monoenergetic images (VMIs), iodine density maps, virtual non-contrast images (VNC), and virtual non-calcium (VNCa) for bone marrow edema (BME) detection. The diverse array of images obtained through DECT acquisitions offers numerous benefits, including enhanced lesion detection and characterization, precise determination of material composition, decreased iodine dose, and reduced artifacts. These versatile applications play an increasingly significant role in tumor assessment and oncologic imaging, encompassing the diagnosis of primary tumors, local and metastatic staging, post-therapy evaluation, and complication management. This article provides a comprehensive review of the principal applications and post-processing techniques of DECT, with a specific focus on its utility in managing oncologic patients.
Collapse
Affiliation(s)
- Giovanni Foti
- Department of Radiology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (C.L.); (F.L.)
| | - Giorgio Ascenti
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, 98122 Messina, Italy;
| | - Andrea Agostini
- Department of Clinical Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy
| | - Chiara Longo
- Department of Radiology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (C.L.); (F.L.)
| | - Fabio Lombardo
- Department of Radiology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (C.L.); (F.L.)
| | - Alessandro Inno
- Department of Oncology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (A.I.); (A.M.); (S.G.)
| | - Alessandra Modena
- Department of Oncology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (A.I.); (A.M.); (S.G.)
| | - Stefania Gori
- Department of Oncology, IRCCS Ospedale Sacro Cuore Don Calabria, Via Don A. Sempreboni 5, 37024 Negrar, Italy; (A.I.); (A.M.); (S.G.)
| |
Collapse
|