1
|
Baryeh K, Sochart DH. Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review. Arch Orthop Trauma Surg 2022; 142:4075-4085. [PMID: 35048171 DOI: 10.1007/s00402-021-04302-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 12/04/2021] [Indexed: 11/02/2022]
Abstract
INTRODUCTION Peri-prosthetic fractures (PPFs) are a serious complication of total hip arthroplasty (THA) associated with significant morbidity, mortality and re-operation similar to the rates seen following femoral neck fractures. When exploring the PPF rates around cemented stems, many studies combine the results of composite beam and taper-slip stems despite their different philosophies. This review looks specifically at PPFs with the use of cemented stems of the taper-slip philosophy to evaluate the demographics, PPF rate and fracture patterns in this patient cohort. MATERIALS AND METHODS A systematic search of Embase, Medline and CINAHL databases was performed to seek studies involving the use of cemented, polished, taper-slip stems, reporting on a rate of post-operative PPF and not involving patient cohorts that were exclusively hip fracture or revision arthroplasty. RESULTS 27 studies reported on 505 PPFs with an average time from primary operation to PPF of 71.2 months (2-301 months). The average age of patients who sustained PPFs was 70.6 years (53.5-82 years) and the majority were female (64.2%). The Vancouver B2 fracture type was most common (39.5%). Open reduction and internal fixation represented the management of choice in 61.2% of PPFs. There was a re-operation rate of 11.4%. CONCLUSION This review suggests an association with being older and female, and a greater risk of PPFs secondary to low energy falls in cemented polished taper-slip stems.
Collapse
Affiliation(s)
- Kwaku Baryeh
- Education Centre, West Middlesex University Hospital, Twickenham Road, Middlesex, TW7 6AF, UK.
| | - David H Sochart
- The Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom General Hospital, Dorking Road, Epsom, KT18 7EG, UK
| |
Collapse
|
2
|
Baryeh K, Wang C, Sochart DH. Periprosthetic femoral fractures around the original cemented polished triple-tapered C-stem femoral implant: a consecutive series of 500 primary total hip arthroplasties with an average follow-up of 15 years. Arch Orthop Trauma Surg 2022:10.1007/s00402-022-04712-x. [PMID: 36447057 PMCID: PMC9708125 DOI: 10.1007/s00402-022-04712-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Accepted: 11/22/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The true incidence of periprosthetic femoral fracture (PFF) around cemented polished taper-slip implants remains largely unknown. Registries usually only capture PFFs that result in revision, missing those managed non-operatively or treated by open reduction and internal fixation (ORIF). This study reports the long-term rate of PFF with the original triple-tapered C-stem femoral implant. MATERIALS AND METHODS A prospective review of a consecutive series of 500 primary total hip arthroplasties (THAs) performed at a single centre between March 2000 and December 2005, with average follow-up of 15 years (12-19 years). RESULTS There were 500 consecutive THAs in 455 patients. Seven PFFs (1.4%) occurred in seven patients at an average of 7.9 years (range 2-11.5) from the primary arthroplasty. Five PFFs were managed by ORIF, one Vancouver B3 fracture was revised for a loose implant and one patient was treated non-operatively. Average age at primary operation was 74 years (67-87) and BMI averaged 27.3 (22-31). There was no typical fracture pattern and no statistically significant associations with patient demographics (age, gender, BMI, diagnosis) or prosthetic details (size, offset, alignment, cement mantle, subsidence). Survivorship to the occurrence of PFF was 99% (97.3-99.6%) at 10 years and 97.8% (95.5-99.0%) at 15. CONCLUSION A PFF rate of 1.4% at an average follow-up of 15 years represents the true incidence of PFF with the use of the original triple-tapered C-Stem femoral implant, similar to that of published Exeter series (1.85%) but lower than the CPT (3.3%).
Collapse
Affiliation(s)
- Kwaku Baryeh
- Postgraduate Medical Education, West Middlesex University Hospital, Twickenham Road, Islewoth, TW7 6AF Middlesex UK
| | - Chao Wang
- Department of Statistics, Kingston University, River House, 53-57 High Street, Kingston upon Thames, KT1 1LQ Surrey UK
| | - David H. Sochart
- The Academic Unit, South West London Elective Orthopaedic Centre, Dorking Road, Epsom, KT18 7EG UK ,The School of Health and Society, University of Salford, Prestwood Road, Salford, M50 2EQ Manchester UK
| |
Collapse
|
3
|
Miyamoto S, Iida S, Suzuki C, Kawamoto T, Shinada Y, Ohtori S. Minimum 10-Year Follow-Up of Total Hip Arthroplasty With a Collarless Triple-Tapered Polished Cemented Stem With Line-to-Line Implantation Using a Direct Anterior Approach. J Arthroplasty 2022; 37:2214-2224. [PMID: 35588903 DOI: 10.1016/j.arth.2022.05.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 05/01/2022] [Accepted: 05/11/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The Trilliance stem (B. Braun-Aesculap, Tuttlingen, Germany), a novel collarless triple-tapered polished stem, was introduced in 2009. The aim of this study is to evaluate the long-term clinical and radiological results of the Trilliance stem with line-to-line implantation in primary total hip arthroplasty using a direct anterior approach. METHODS A consecutive retrospective series of 130 patients (151 hips) who underwent total hip arthroplasty between February 2009 and August 2011 were evaluated for a minimum of 10 years. Of these, 87.4% had a diagnosis of secondary osteoarthritis based on developmental hip dysplasia. Clinical and radiological results, complications were evaluated and survival analysis was performed. RESULTS The mean follow-up was 10.7 years (range, 10.0-12.1). Thirteen hips (13 patients, 6.8%) were lost to follow-up. Adequate cementation (Barrack grade A) was achieved in 136 hips (93.8%) 1 week post-operatively. Nearly all (144 hips, 99.3%) had been inserted within the range of 3°. No significant differences were identified between high- (≥30 procedures/year) and low- (<30 procedures/year) volume surgeons. The Kaplan-Meier survival analysis with revision of the femoral component for aseptic loosening, revision of the femoral component for any reason and revision of either component for any reason as the end points, cumulative survivorship was 100.0%, 97.6% (95% confidence interval (CI) 95.4-100.0) and 96.5% (95% CI 93.8-99.3) at 10 years, respectively. CONCLUSION The Trilliance stem with line-to-line implantation using a direct anterior approach has an excellent clinical and radiological outcome at a minimum of 10 years' follow-up. LEVEL OF EVIDENCE Level IV, Retrospective cohort study.
Collapse
Affiliation(s)
- Shuichi Miyamoto
- Department of Orthopedic Surgery, Matsudo City General Hospital, Chiba, Japan
| | - Satoshi Iida
- Department of Orthopedic Surgery, Matsudo City General Hospital, Chiba, Japan
| | - Chiho Suzuki
- Department of Orthopedic Surgery, Matsudo City General Hospital, Chiba, Japan
| | - Taisei Kawamoto
- Department of Orthopedic Surgery, Matsudo City General Hospital, Chiba, Japan
| | - Yoshiyuki Shinada
- Department of Orthopedic Surgery, Matsudo City General Hospital, Chiba, Japan
| | - Seiji Ohtori
- Department of Orthopedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
| |
Collapse
|
4
|
Clinical Outcomes and Survivorship of Hybrid Total Hip Arthroplasty Performed Through the Anterior Approach. J Arthroplasty 2022; 37:S556-S559. [PMID: 35660198 DOI: 10.1016/j.arth.2021.12.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 12/11/2021] [Accepted: 12/20/2021] [Indexed: 02/02/2023] Open
Abstract
INTRODUCTION There is growing evidence that cemented femoral stems have lower complication rates in the elderly due to lower rates of periprosthetic fracture. The main objective of this study was to analyze the survival rate of a hybrid total hip arthroplasty (THA) construct utilizing a taper-slip femoral stem implanted through the anterior approach (AA). Secondary outcome measures were the complication rate, the rate of aseptic loosening, coronal plane alignment of the stem, and the grade of the cement mantle. METHODS Patients who underwent AA hybrid THA from 2013 to 2020 were included. Indications for a cemented stem were age over 70 or patients with poor bone quality. Descriptive statistics were calculated for patient characteristics. Serial radiographs were reviewed for component alignment and for evidence of implant loosening. The survival of the femoral stem was recorded, with failure defined as femoral stem revision for any reason or radiographic evidence of implant loosening. RESULTS A total of 473 hybrid THA in 426 patients were identified, with a mean age of 76 years. Mean follow-up was 38 months. Femoral stem survival was 99.2%. There were no cases of aseptic loosening of the femoral component. Mean coronal stem alignment was 0.2 degrees varus, and all were within 5 degrees of neutral. Cement mantle grade was either A or B in 94% of cases. CONCLUSION AA hybrid THA is an excellent option in elderly patients, or patients with poor bone quality, with a femoral stem survival rate of 99.2% and a 0% rate of aseptic loosening.
Collapse
|
5
|
The influence of calcar collar and surface finish in the cemented femoral component on the incidence of postoperative periprosthetic femoral fracture at a minimum of five years after primary total hip arthroplasty. Injury 2022; 53:2247-2258. [PMID: 35292157 DOI: 10.1016/j.injury.2022.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 01/13/2022] [Accepted: 03/05/2022] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Cemented femoral component design including its mechanical behavior in total hip arthroplasty (THA) has influenced the occurrence of postoperative periprosthetic femoral fracture (PPFF). The main aim of this study was to investigate the influence of the calcar collar and surface finish in the cemented femoral component on the risk of PPFF. MATERIALS AND METHODS This retrospective review was undertaken of 1082 primary THAs in 912 patients using cemented femoral components followed for a minimum of five years (mean, 9.4 years; range, 5-24 years). The incidence of PPFF, patients' demographics and surgical details were evaluated. Kaplan-Meier survivorship analysis was performed for four different outcomes: any PPFF, revision of the femoral component for PPFF, aseptic loosening, and for any reason. RESULTS The overall incidence of PPFFs was 1.0% (n = 11): 1.4% (n = 10) in the collarless polished (CLP) group, none in the collared polished (CP) group and 0.6% (n = 1) in the collared non-polished (CNP) group (p > 0.05). Kaplan-Meier survival analysis for the femoral component at 12 years with PPFF as the end point was 97.4% (95% confidence interval [CI], 94.9 to 99.8) in the collarless group and 99.7% (95% CI, 99.1 to 100) in the collared group (p = 0.048). With revision of the femoral component for aseptic loosening as the end point, survivorship was 100.0% in the CLP and CP groups, and 98.1% (95% CI, 95.9 to 100) in the CNP group (CLP vs CP, p > 0.999; CLP vs CNP, p = 0.001; CP vs CNP, p = 0.112). CONCLUSION This study demonstrated that the calcar collar in the cemented femoral component could play an important role to reduce the incidence of PPFF. The surface finish in the cemented femoral components influenced the incidence of femoral component revision for aseptic loosening over 5-12 years. Surgeons should consider not only the geometry and the mechanical function of the femoral components based on different design philosophies, but also potential complications associated with different designs that may require revision arthroplasty.
Collapse
|
6
|
Khanuja HS, Mekkawy KL, MacMahon A, McDaniel CM, Allen DA, Moskal JT. Revisiting Cemented Femoral Fixation in Hip Arthroplasty. J Bone Joint Surg Am 2022; 104:1024-1033. [PMID: 35298444 PMCID: PMC9969348 DOI: 10.2106/jbjs.21.00853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
➤ The primary means of femoral fixation in North America is cementless, and its use is increasing worldwide, despite registry data and recent studies showing a higher risk of periprosthetic fracture and early revision in elderly patients managed with such fixation than in those who have cemented femoral fixation. ➤ Cemented femoral stems have excellent long-term outcomes and a continued role, particularly in elderly patients. ➤ Contrary to historical concerns, recent studies have not shown an increased risk of death with cemented femoral fixation. ➤ The choice of femoral fixation method should be determined by the patient's age, comorbidities, and bone quality. ➤ We recommend considering cemented femoral fixation in patients who are >70 years old (particularly women), in those with Dorr type-C bone or a history of osteoporosis or fragility fractures, or when intraoperative broach stability cannot be obtained.
Collapse
Affiliation(s)
- Harpal S. Khanuja
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| | - Kevin L. Mekkawy
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| | - Aoife MacMahon
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| | - Claire M. McDaniel
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| | - Donald A. Allen
- Department of Orthopaedic Surgery, Carilion Clinic, Roanoke, Virginia
| | - Joseph T. Moskal
- Department of Orthopaedic Surgery, Carilion Clinic, Roanoke, Virginia
| |
Collapse
|
7
|
Rouzrokh P, Wyles CC, Kurian SJ, Ramazanian T, Cai JC, Huang Q, Zhang K, Taunton MJ, Maradit Kremers H, Erickson BJ. Deep Learning for Radiographic Measurement of Femoral Component Subsidence Following Total Hip Arthroplasty. Radiol Artif Intell 2022; 4:e210206. [PMID: 35652119 DOI: 10.1148/ryai.210206] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 03/30/2022] [Accepted: 04/15/2022] [Indexed: 11/11/2022]
Abstract
Femoral component subsidence following total hip arthroplasty (THA) is a worrisome radiographic finding. This study developed and evaluated a deep learning tool to automatically quantify femoral component subsidence between two serial anteroposterior (AP) hip radiographs. The authors' institutional arthroplasty registry was used to retrospectively identify patients who underwent primary THA from 2000 to 2020. A deep learning dynamic U-Net model was trained to automatically segment femur, implant, and magnification markers on a dataset of 500 randomly selected AP hip radiographs from 386 patients with polished tapered cemented femoral stems. An image processing algorithm was then developed to measure subsidence by automatically annotating reference points on the femur and implant, calibrating that with respect to magnification markers. Algorithm and manual subsidence measurements by two independent orthopedic surgeon reviewers in 135 randomly selected patients were compared. The mean, median, and SD of measurement discrepancy between the automatic and manual measurements were 0.6, 0.3, and 0.7 mm, respectively, and did not demonstrate a systematic tendency between human and machine. Automatic and manual measurements were strongly correlated and showed no evidence of significant differences. In contrast to the manual approach, the deep learning tool needs no user input to perform subsidence measurements. Keywords: Total Hip Arthroplasty, Femoral Component Subsidence, Artificial Intelligence, Deep Learning, Semantic Segmentation, Hip, Joints Supplemental material is available for this article. © RSNA, 2022.
Collapse
Affiliation(s)
- Pouria Rouzrokh
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Cody C Wyles
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Shyam J Kurian
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Taghi Ramazanian
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Jason C Cai
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Qiao Huang
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Kuan Zhang
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Michael J Taunton
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Hilal Maradit Kremers
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| | - Bradley J Erickson
- Department of Radiology, Radiology Informatics Laboratory (P.R., J.C.C., Q.H., K.Z., B.J.E.), Department of Health Sciences Research (C.C.W., T.R., M.J.T., H.M.K.), Department of Orthopedic Surgery (C.C.W., T.R., M.J.T., H.M.K.), Department of Clinical Anatomy (C.C.W.), and Mayo Clinic Alix School of Medicine (S.J.K.), Mayo Clinic, 200 First St SW, Rochester, MN 55905
| |
Collapse
|
8
|
Ebert JR, Nivbrant NO, Petrov V, Yates P, Wood DJ. A 2-year prospective clinical and bone density evaluation, with a subset undergoing radiostereometric analysis, using the Absolut cemented stem. ANZ J Surg 2022; 92:830-836. [PMID: 35106881 PMCID: PMC9303330 DOI: 10.1111/ans.17519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Revised: 01/06/2022] [Accepted: 01/13/2022] [Indexed: 11/27/2022]
Abstract
Background Total hip arthroplasty (THA) is common though the investigation of new prostheses requires a practical, step‐wise introduction. This study reports the 2‐year clinical results and periprosthetic bone mineral density (BMD) changes, along with a subset undergoing Radiostereometric analysis (RSA), in patients undergoing primary cemented THA using a new highly polished, double tapered, collarless femoral stem (Absolut). Methods Between August 2013 and December 2016, 47 patients with a mean age of 74.2 years (range 36–89) underwent 51 THAs with the Absolut. All patients underwent clinical assessment pre‐surgery and at 6 weeks, 3, 12 and 24 months using the Oxford and Harris Hip Scores, as well as Dual Energy X‐ray Absorptiometry (DEXA) to assess BMD within 2–4 weeks post‐surgery, 12 and 24 months. RSA was undertaken in a patient subset (the first n = 30) early post‐surgery (1–2 days) and 3, 12 and 24 months. Results All clinical scores significantly improved (p < 0.05). RSA revealed a mean subsidence of 0.78 mm at 3 months, 1.23 mm at 12 months and 1.51 mm at 24 months. Anterior–posterior and medial‐lateral translation was negligible. A significant increase (p = 0.020) in BMD was observed in Gruen zone 1, though no significant changes were observed for any other zone up until 2 years. Two patients acquired an early post‐operative deep vein thrombosis that were treated accordingly and resolved, with no further complications or re‐operations. Conclusion The Absolut cemented femoral stem demonstrated good outcomes, BMD changes consistent with sound prosthesis integration and patterns of post‐operative micromotion observed in other successful cemented stems.
Collapse
Affiliation(s)
- Jay R Ebert
- School of Human Sciences (Exercise and Sport Science), University of Western Australia, Perth, Western Australia, Australia.,HFRC, Perth, Western Australia, Australia.,Orthopaedic Research Foundation of Western Australia, Perth, Western Australia, Australia
| | - Nils O Nivbrant
- Perth Orthopaedic Institute, Perth, Western Australia, Australia
| | | | - Piers Yates
- Orthopaedic Research Foundation of Western Australia, Perth, Western Australia, Australia.,Fremantle Hospital, Fremantle, Western Australia, Australia
| | - David J Wood
- Perth Orthopaedic Institute, Perth, Western Australia, Australia.,School of Surgery (Orthopaedics), University of Western Australia, Perth, Western Australia, Australia
| |
Collapse
|
9
|
Gausden EB, Abdel MP, Mabry TM, Berry DJ, Trousdale RT, Sierra RJ. Midterm Results of Primary Exeter Cemented Stem in a Select Patient Population. J Bone Joint Surg Am 2021; 103:1826-1833. [PMID: 33974592 DOI: 10.2106/jbjs.20.01829] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Most North American surgeons predominantly use uncemented stems in primary total hip arthroplasties (THAs) and reserve cemented stems for selected older patients and those with poor bone quality. However, data on this "selective use" strategy for cemented stems in the population at risk for periprosthetic fracture and implant loosening are limited. The purpose of this study was to describe implant survivorship, complications, and radiographic results of a specific collarless, polished, tapered cemented stem (Exeter; Stryker) used selectively in a predominantly elderly population undergoing primary THA. METHODS We identified 386 patients who underwent a total of 423 primary THAs with selectively utilized Exeter stems for the treatment of osteoarthritis between 2006 and 2017. In the same time period, 11,010 primary THAs were performed with uncemented stems and 961 with non-Exeter cemented stems. The mean patient age was 77 years, 71% were female, and the mean body mass index was 29 kg/m2. Competing risk analysis accounting for death was utilized to determine cumulative incidences of revision and reoperation. The mean follow-up was 5 years (range, 2 to 12 years). RESULTS The 10-year cumulative incidence of any femoral component revision in this patient cohort was 4%, with 10 stems revised at the time of the latest follow-up. There were no intraoperative femoral fractures. The indications for revision were postoperative periprosthetic femoral fracture (n = 6), dislocation (n = 3), and infection (n = 1). There were no revisions for femoral loosening. The 10-year cumulative incidence of reoperation was 10%. The 10-year cumulative incidence of Vancouver B periprosthetic femoral fracture was 2%. Radiographically, there were no cases of aseptic loosening or osteolysis. There was a significant improvement in median Harris hip score, from 53 preoperatively to 92 at a mean follow-up of 5 years (p < 0.001). CONCLUSIONS The strategy of selectively utilizing a collarless, polished, tapered cemented stem produced a low (4%) cumulative incidence of stem revision at 10 years postoperatively and resulted in no cases of aseptic loosening. The use of the Exeter stem did not eliminate postoperative femoral fractures in this predominantly elderly, female patient population. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Elizabeth B Gausden
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY
| | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Tad M Mabry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
10
|
Mjöberg B. Hip prosthetic loosening: A very personal review. World J Orthop 2021; 12:629-639. [PMID: 34631447 PMCID: PMC8472441 DOI: 10.5312/wjo.v12.i9.629] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 05/03/2021] [Accepted: 08/03/2021] [Indexed: 02/06/2023] Open
Abstract
Hip prosthetic loosening is often difficult to detect at an early stage, and there has been uncertainty for a long time as to when the loosening occurs and thus to the basic causes. By comparing different diagnostic methods, we found that loosening is best defined as prosthetic migration and measured by radiostereometric analysis. Convincing evidence indicates that poor interlock, poor bone quality, and resorption of a necrotic bone bed may initiate loosening during or shortly after surgery; this forms the basis of the theory of early loosening. Biomechanical factors do affect the subsequent progression of loosening, which may increase subclinically during a long period of time. Eventually, the loosening may be detected on standard radiographs and may be interpreted as late loosening but should to be interpreted as late detection of loosening. The theory of early loosening explains the rapid early migration, the development of periprosthetic osteolysis and granulomas, the causality between wear and loosening, and largely the epidemiology of clinical failure of hip prostheses. Aspects discussed are definition of loosening, the pattern of early migration, the choice of migration threshold, the current understanding of loosening, a less exothermic bone cement, cemented taper-slip stems, a new exciting computed tomography-based technique for simpler implant migration studies, and research suggestions.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopedics, Lund University, Lund SE-221 00, Sweden
| |
Collapse
|
11
|
Slullitel PA, Garcia-Barreiro GG, Oñativia JI, Zanotti G, Comba F, Piccaluga F, Buttaro MA. Selected Vancouver B2 periprosthetic femoral fractures around cemented polished femoral components can be safely treated with osteosynthesis. Bone Joint J 2021; 103-B:1222-1230. [PMID: 34192924 DOI: 10.1302/0301-620x.103b7.bjj-2020-1809.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
AIMS We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty. METHODS We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups. RESULTS In all, nine (8.01%) surgical failures were detected. All failures occurred within the first 24 months following surgery. The 24-month implant survival was 95.4% (95% confidence interval (CI) 89.13 to 100) for B1 fractures treated with internal fixation, 90% (95% CI 76.86 to 100) for B2 PFFs treated with osteosynthesis-only, and 85.8% (95% CI 74.24 to 97.36) for B2 fractures treated with revision THA, without significant differences between groups (p = 0.296). Readmissions and major adverse events including mortality were overall high, but similar between groups (p > 0.05). The two-year patient survival rate was 87.1% (95% CI 77.49 to 95.76), 66.7% (95% CI 48.86 to 84.53), and 84.2% (95% CI 72.63 to 95.76), for the B1 group, B2 osteosynthesis group, and B2 revision group, respectively (p = 0.102). CONCLUSION Implant survival in Vancouver B2 PFFs treated with internal fixation was similar to that of B1 fractures treated with the same method and to B2 PFFs treated with revision arthroplasty. Low-demand, elderly patients with B2 fractures around well-cemented polished femoral components with an intact bone-cement interface can be safely treated with internal fixation. Cite this article: Bone Joint J 2021;103-B(7):1222-1230.
Collapse
Affiliation(s)
- Pablo A Slullitel
- Sir John Charnley Hip Surgery Unit, Institute of Orthopaedics Carlos E. Ottolenghi, Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Gonzalo G Garcia-Barreiro
- Sir John Charnley Hip Surgery Unit, Institute of Orthopaedics Carlos E. Ottolenghi, Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - José I Oñativia
- Adult Reconstructive Surgery Unit, Department of Orthopaedic Surgery, Sanatorio del Norte, Tucumán, Buenos Aires, Argentina
| | - Gerardo Zanotti
- Sir John Charnley Hip Surgery Unit, Institute of Orthopaedics Carlos E. Ottolenghi, Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Fernando Comba
- Sir John Charnley Hip Surgery Unit, Institute of Orthopaedics Carlos E. Ottolenghi, Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Francisco Piccaluga
- Sir John Charnley Hip Surgery Unit, Institute of Orthopaedics Carlos E. Ottolenghi, Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Martin A Buttaro
- Sir John Charnley Hip Surgery Unit, Institute of Orthopaedics Carlos E. Ottolenghi, Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| |
Collapse
|
12
|
Ohashi H, Iida S, Minato I. Minimum ten-year outcome of a triple-tapered femoral stem implanted with line-to-line cementing technique. BMC Musculoskelet Disord 2021; 22:601. [PMID: 34193115 PMCID: PMC8246659 DOI: 10.1186/s12891-021-04484-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 06/14/2021] [Indexed: 11/25/2022] Open
Abstract
Background A triple-tapered polished femoral stem was implanted with line-to-line cementing technique. The purpose of this study was to determine the survivorship, loosening rate, stem subsidence, radiologic changes and clinical outcomes in the minimum 10-year follow-up. Methods This was a retrospective study done in three institutes. Finally, 118 hips in 97 patients could be followed-up at the mean follow-up period of 126.3 months. The survivorship, radiological and clinical outcomes were investigated. Results Radiologically, 107 hips (90.7%) were categorized to Barrack cementing grade A, and 108 stems (91.5%) were inserted in neutral position. All hips were not loose and were not revised due to any reason. Survival with revision for any reason as the endpoint was 100% after 10 years. At the last follow-up, the mean subsidence was 0.43 mm, and the subsidence was less than 1 mm in 110 hips (93.2%). JOA hip score improved from 42.7 ± 8.9 points preoperatively to 92.8 ± 6.8 points at the last follow-up. No patient complained thigh pain. Conclusions Line-to-line cementing technique with use of a triple-tapered polished stem was effective to achieve good cementation quality and centralization of the stem. The subsidence was small, and the minimum 10-year results were excellent without any failures related to the stem. Trial registration Retrospectively registered.
Collapse
Affiliation(s)
- Hirotsugu Ohashi
- Department of Orthopaedic Surgery, Osaka Saiseikai Nakatsu Hospital, 2-10-39 Shibata, Kita-ku, Osaka, 530-0012, Japan.
| | - Satoshi Iida
- Department of Orthopaedic Surgery, Matsudo City General Hospital, 933-1 Sendabori, Matsudo, Chiba, 270-2296, Japan
| | - Izumi Minato
- Department of Orthopaedic Surgery, Niigata Rinko Hospital, 1-114-3 Momoyama-cho, higashi-ku, Niigata, 950-8725, Japan
| |
Collapse
|
13
|
Baryeh K, Mendis J, Sochart DH. Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review. EFORT Open Rev 2021; 6:331-342. [PMID: 34150327 PMCID: PMC8183154 DOI: 10.1302/2058-5241.6.200086] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The literature was reviewed to establish the levels of stem subsidence for both double and triple-tapered implants in order to determine whether there were any differences in subsidence levels with regard to the methods of measurement, the magnitude and rate of subsidence and clinical outcomes. All studies reporting subsidence of polished taper-slip stems were identified. Patient demographics, implant design, radiological findings, details of surgical technique, methods of measurement and levels of subsidence were collected to investigate which factors were related to increased subsidence. Following application of inclusion and exclusion criteria, 28 papers of relevance were identified. The studies initially recruited 3090 hips with 2099 being available for radiological analysis at final follow-up. Patient age averaged 68 years (42–70), 60.4% were female and the average body mass index (BMI) was 27.4 kg/m2 (24.1–29.2). Mean subsidence at one, two, five and 10 years was 0.97 mm, 1.07 mm, 1.47 mm and 1.61 mm respectively. Although double-tapered stems subsided more than triple-tapered stems at all time points this was not statistically significant (p > 0.05), nor was the method of measurement used (p > 0.05). We report the levels of subsidence at which clinical outcomes and survivorship remain excellent, but based on the literature it was not possible to determine a threshold of subsidence beyond which failure was more likely. There were relatively few studies of triple-tapered stems, but given that there were no statistically significant differences, the levels presented in this review can be applied to both double and triple-tapered designs.
Cite this article: EFORT Open Rev 2021;6:331-342. DOI: 10.1302/2058-5241.6.200086
Collapse
Affiliation(s)
- Kwaku Baryeh
- The Academic Surgical Unit, South West London Elective Orthopaedic Centre, UK
| | | | - David H Sochart
- The Academic Surgical Unit, South West London Elective Orthopaedic Centre, UK
| |
Collapse
|
14
|
Joanroy R, Stork-Hansen J, Rotwitt L, Viberg B. Cemented hemiarthroplasty for femoral neck fracture patients: collarless, polished tapered stem (CPT) versus anatomic matte stem (Lubinus SP2). EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2021; 31:855-860. [PMID: 33839931 DOI: 10.1007/s00590-021-02948-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 03/21/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Cemented hemiarthroplasty is a well-documented treatment for patients with femoral neck fractures (FNFs). However, there are not many cohort studies comparing different types of hemiarthroplasty (HA). OBJECTIVE To compare CPT and Lubinus SP2 HA for FNF patients concerning complications and radiological measurements. METHODS From January 1, 2013, CPT was introduced instead of Lubinus SP2 as the new cemented HA due to a regional procurement. Data were retrieved 3 years prior and after the introduction. All patient health records were retrospectively reviewed for types of implant, American Society of Anesthesiologists (ASA) score and duration of admission. All X-ray images were analyzed for radiological measurements concerning offset, stem angulation and cement filling. Mortality and major complications within 1 year were retrieved from patient health records as well as the Danish National Patient Registry. Major complications were defined as dislocations, periprosthetic fractures and revisions. RESULTS 584 cemented HA were included, 300 CPT and 284 with Lubinus SP2. The mean age (SD) was 82 (8.2) years, and there was no baseline difference between the groups concerning age, sex, ASA score and mortality. There were 8.7% major complications for CPT and 9.2% for Lubinus SP2 (p = 0.836). There were, however, seven periprosthetic fractures in the CPT group and one in the Lubinus SP2 group (p = 0.04). In contrast, there were 20 dislocations in the Lubinus SP2 group and 10 in the CPT group (p = 0.042). There was no statistical difference between the stem angulation and periprosthetic fractures (p = 0.824) or major complications (p = 0.602). The Lubinus SP2 had a mean plus 2.7 mm offset postoperatively (p = 0.001), while the CPT had plus 10.6 mm (p < 0.000). The mean (SD) angle of the stems was 1.39 (1.75) degrees for Lubinus SP2 and 2.46 (1.99) for CPT. There was no difference in cementation (p = 0.308). CONCLUSION There was no overall statistical difference between the CPT and Lubinus SP2 stem regarding major complications. However, the CPT had a higher prevalence of periprosthetic fractures, while the Lubinus SP2 had a higher dislocation prevalence. The CPT stem had overcorrection of offset and a higher degree of varus positioning.
Collapse
Affiliation(s)
- Rajzan Joanroy
- Department of Orthopaedic Surgery and Traumatology, Kolding Hospital, Part of Hospital Lillebaelt, Kolding, Denmark.
| | - Jesper Stork-Hansen
- Department of Orthopaedic Surgery and Traumatology, Kolding Hospital, Part of Hospital Lillebaelt, Kolding, Denmark
| | - Lars Rotwitt
- Department of Orthopaedic Surgery and Traumatology, Kolding Hospital, Part of Hospital Lillebaelt, Kolding, Denmark
| | - Bjarke Viberg
- Department of Orthopaedic Surgery and Traumatology, Kolding Hospital, Part of Hospital Lillebaelt, Kolding, Denmark.,Institute for Regional Health Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
15
|
Cassar-Gheiti AJ, McColgan R, Kelly M, Cassar-Gheiti TM, Kenny P, Murphy CG. Current concepts and outcomes in cemented femoral stem design and cementation techniques: the argument for a new classification system. EFORT Open Rev 2020; 5:241-252. [PMID: 32377392 PMCID: PMC7202038 DOI: 10.1302/2058-5241.5.190034] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
Cemented implant fixation design principles have evolved since the 1950s, and various femoral stem designs are currently in use to provide a stable construct between the implant–cement and cement–bone interfaces. Cemented stems have classically been classified into two broad categories: taper slip or force closed, and composite beams or shaped closed designs. While these simplifications are acceptable general categories, there are other important surgical details that need to be taken into consideration such as different broaching techniques, cementing techniques and mantle thickness. With the evolution of cemented implants, the introduction of newer implants which have hybrid properties, and the use of different broaching techniques, the classification of a very heterogenous group of implants into simple binary categories becomes increasingly difficult. A more comprehensive classification system would aid in comparison of results and better understanding of the implants’ biomechanics. We review these differing stem designs, their respective cementing techniques and geometries. We then propose a simple four-part classification system and summarize the long-term outcomes and international registry data for each respective type of cemented prosthesis.
Cite this article: EFORT Open Rev 2020;5:241-252. DOI: 10.1302/2058-5241.5.190034
Collapse
Affiliation(s)
| | | | - Martin Kelly
- Connolly Hospital, Orthopaedic Department, Dublin, Ireland
| | | | - Paddy Kenny
- Cappagh National Orthopaedic Hospital, Dublin, Ireland.,Connolly Hospital, Orthopaedic Department, Dublin, Ireland
| | | |
Collapse
|
16
|
Keeling P, Howell JR, Kassam AAM, Sathu A, Timperley AJ, Hubble MJW, Wilson MJ, Whitehouse SL. Long-Term Survival of the Cemented Exeter Universal Stem in Patients 50 Years and Younger: An Update on 130 Hips. J Arthroplasty 2020; 35:1042-1047. [PMID: 31882346 DOI: 10.1016/j.arth.2019.11.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2019] [Revised: 11/04/2019] [Accepted: 11/07/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND There is variable evidence regarding survivorship beyond 20 years of total hip arthroplasties in young patients. We report the long-term results of the Exeter cemented hip system in patients ≤50 years at minimum of 20 years. METHODS Clinical and radiological outcomes of 130 consecutive total hip arthroplasties in 107 patients aged 50 years or younger at primary operation were reviewed; 77% had a diagnosis other than osteoarthritis. All patients were followed at 5-year intervals, no patients were lost to follow-up, and the status of every implant is known. RESULTS Mean age at surgery was 41.8 (17-50) years. Mean follow-up was 22.0 (20.0-26.1) years. There were 79 hips surviving, 14 hips (11 patients) deceased, and 37 hips revised. Reasons for revision: 29 hips for aseptic cup loosening (26 stems revised using cement-in-cement, three left in-situ); three stems for femoral osteolysis, two related to acetabular polyethylene wear (14.1 and 17.0 years), one with Gaucher's disease (21.1 years); one broken stem (12.9 years); one cup for instability (4.3 years-stem revised using cement-in-cement); and two hips with infection (8.5 and 23.8 years). There were no cases of aseptic loosening of the Exeter stem. There were no radiologically loose stems although eight patients had radiological evidence of loosening of the cemented cup. Survivorship at 22 years was 74.9% for revision for all causes and 96.3% for revision of the stem for aseptic loosening or lysis. CONCLUSION The Exeter cemented stem has excellent survivorship at minimum 20 years in young patients. Acetabular component survivorship was less favorable, but the advent of highly cross-linked polyethylene may improve this in the long term.
Collapse
Affiliation(s)
- Parnell Keeling
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK
| | - Jonathan R Howell
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK
| | - Al-Amin M Kassam
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK
| | - Anubhav Sathu
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK
| | - A John Timperley
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK; College of Engineering, Maths and Physical Science, University of Exeter, Exeter, Devon, UK
| | - Matthew J W Hubble
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK
| | - Matthew J Wilson
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK
| | - Sarah L Whitehouse
- Queensland University of Technology (QUT), Brisbane, Queensland, Australia
| |
Collapse
|
17
|
Long-term outcome of cemented total hip arthroplasty with the Charnley-type femoral stem made of titanium alloy. J Orthop Sci 2019; 24:1047-1052. [PMID: 31422864 DOI: 10.1016/j.jos.2019.07.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 07/16/2019] [Accepted: 07/19/2019] [Indexed: 11/23/2022]
Abstract
BACKGROUND Total hip arthroplasty is a successful treatment for hip diseases including osteoarthritis, osteonecrosis of the femoral head, and rheumatoid arthritis. Various designs of cemented femoral stems made of stainless steel and titanium alloy have been used. Among them, Charnley-type femoral stems made of stainless steel have often been reported to have good long-term outcome. However, the long-term outcome of the Charnley-type femoral stem made of Ti alloy is yet to be reported. We conducted a retrospective study to assess the long-term outcome of cemented primary total hip arthroplasty with the Charnley-type femoral stem made of Ti alloy. METHODS Between October 1988 and February 1997, 341 cemented primary total hip arthroplasties with the Charnley-type femoral stem made of Ti alloy were consecutively performed in our hospital. Among these, 164 patients (211 hips) who underwent this procedure were followed up for more than 12 years, and the surgical hips were analysed clinically and radiologically. The mean follow-up period was 20.6 years. Kaplan-Meier survival analyses were performed to assess femoral component survival. Factors affecting stem revision for aseptic loosening were also investigated using log-rank tests. RESULTS In the functional assessment, the preoperative Japanese Orthopaedic Association score significantly improved from 47.2 points preoperatively to 79.0 points at the final follow-up. Eventually, 33 femoral stems were revised, of which 12 were revised for aseptic loosening. In the Kaplan-Meier survival analysis, the 20-year survival rates with stem revision for aseptic loosening and radiological stem loosening at the end points were 95.9% and 97.1%, respectively. Original diagnosis (non-osteoarthritis) was the only significant factor for aseptic loosening of the femoral stem. CONCLUSIONS Cemented primary total hip arthroplasty with the Charnley-type femoral stem made of Ti alloy showed excellent outcomes for more than 20 years.
Collapse
|
18
|
Jørgensen PB, Lamm M, Søballe K, Stilling M. Equivalent hip stem fixation by Hi-Fatigue G and Palacos R + G bone cement: a randomized radiostereometric controlled trial of 52 patients with 2 years' follow-up. Acta Orthop 2019; 90:237-242. [PMID: 30931663 PMCID: PMC6534245 DOI: 10.1080/17453674.2019.1595390] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Long-term fixation of cemented femoral stems relies on several factors including cement adhesion and fatigue. Hi-Fatigue is a newer third-generation bone cement with low-viscosity properties at room temperature, good mechanical strength, and stable bone-cement interface in a laboratory testing environment. Palacos bone cement has excellent 10-year survival and is considered gold standard. We compared stem subsidence after fixation with Hi-Fatigue and Palacos bone cements using radiostereometry. Patients and methods - In a patient-blinded randomized controlled trial, 52 patients (30 women) at mean age 76 years (71-87) with osteoarthrosis and no osteoporosis received Hi-Fatigue G or Palacos R + G cement fixation of collarless, polished, double-tapered stems (CPT). Tantalum beads were inserted in the periprosthetic bone. Supine stereoradiographs were obtained postoperatively, 3 months, 6 months, 1 year, and 2 years after surgery. Oxford Hip Score (OHS) and VAS pain were recorded preoperatively and 1 and 2 years after surgery. Cement working times and properties were registered. Results - At 2 years, mean stem subsidence of 1.12 mm (95% CI 0.96-1.29) for Hi-Fatigue and 1.19 mm (CI 1.03-1.34) for Palacos was similar. Likewise, stem version was comparable between cement groups. Mean OHS and VAS pain were similar between cement groups. Cement working times were similar between cement groups, but the mean curing time was longer for Hi-Fatigue (13.7 min) than for Palacos (11.6 min). Interpretation - We found similar and generally low migration of CPT femoral stems inserted with Hi-Fatigue and Palacos bone cement until 2 years' follow-up, which indicates a good long-term survival of polished taper femoral stems inserted with both cement types.
Collapse
Affiliation(s)
- Peter B Jørgensen
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark,Correspondence:
| | - Martin Lamm
- Department of Orthopedic Surgery, Aarhus University Hospital;;
| | - Kjeld Søballe
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark
| | - Maiken Stilling
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark
| |
Collapse
|
19
|
Costi K, Solomon LB, McGee MA, Rickman MS, Howie DW. Advantages in Using Cemented Polished Tapered Stems When Performing Total Hip Arthroplasty in Very Young Patients. J Arthroplasty 2017; 32:1227-1233. [PMID: 28082045 DOI: 10.1016/j.arth.2016.11.031] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Revised: 09/06/2016] [Accepted: 11/15/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The risk of revision following primary total hip arthroplasty (THA) is increased in young patients who undergo THA for pathologies other than primary osteoarthritis. We report the results of primary THA performed with cemented polished stems in patients aged 40 years and younger for pathologies other than primary osteoarthritis. METHODS We investigated 52 patients (65 hips) who underwent primary THA for secondary osteoarthritis with a cemented tapered polished stem between 1990 and 2007. Clinical and radiographic outcomes, available in 46 patients (57 hips), included the Harris Hip Scores, Societe Internationale de Chirurgie Orthopedique et de Traumatologie activity, patient satisfaction, stem survival and reoperations, and assessment of prosthesis-cement-bone radiolucencies, osteolysis, and femoral bone deficiencies. RESULTS Median patient age was 34 years (16-40) and follow-up was 14 years (mean 13, range 5-22). Stem survival to the endpoint revision for loosening was 100% and to the endpoint revision for any reason, excluding infection was 88% (95% confidence interval 78-98) at 16 years. No stem was revised for aseptic loosening. Nine stems were revised for other reasons. Radiographically, one stem was definitely loose at 16 years. The median patient Harris pain score improved from marked pain to no pain at latest follow-up. Patient activity level improved, albeit minimally, for 8 years after surgery. At latest follow-up, 98% of the patients remained satisfied with their surgery. CONCLUSION Primary THA with a cemented polished stem shows excellent results in young patients with pathology other than primary osteoarthritis. In addition, the stem design facilitates cement within cement exchange and therefore preservation of proximal femoral bone stock at revision surgery.
Collapse
Affiliation(s)
- Kerry Costi
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Lucian B Solomon
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital and Discipline of Orthopaedics and Trauma, The University of Adelaide, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Margaret A McGee
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Mark S Rickman
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital and Discipline of Orthopaedics and Trauma, The University of Adelaide, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Donald W Howie
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital and Discipline of Orthopaedics and Trauma, The University of Adelaide, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| |
Collapse
|
20
|
Schmitz MWJL, Bronsema E, de Kam DCJ, Gardeniers JWM, Veth RPH, Schreurs BW. Results of the cemented Exeter femoral component in patients under the age of 40 : an update at ten to 20 years' follow-up. Bone Joint J 2017; 99-B:192-198. [PMID: 28148660 DOI: 10.1302/0301-620x.99b2.38045] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Accepted: 10/03/2016] [Indexed: 11/05/2022]
Abstract
AIMS We carried out a further study of the long-term results of the cemented Exeter femoral component in patients under the age of 40 with a mean follow-up of 13.6 years (10 to 20). PATIENTS AND METHODS We reviewed our original cohort of 104 cemented Exeter stems in 78 consecutive patients with a mean age of 31 years (16 to 39). Only one patient was lost to radiological follow-up. RESULTS A total of six patients (eight hips) had died for reasons unrelated to their surgery. There had been one further periprosthetic fracture from a fall and one fractured femoral stem. No revisions for aseptic loosening were undertaken during the whole study period. Overall, 11 hips had progressive radiolucent lines in one or more zones. The Kaplan Meier survival percentages at ten and 17 years were 97.1% (95% confidence interval (CI) 91.3 to 99.1) and 92.1% (95% CI 74.1 to 97.8) with revision for any reason as the endpoint, and 100% at both ten and 17 years with aseptic loosening (95% CI 83.8 to 100) as the endpoint. No additional hips were classified as radiologically loose. CONCLUSION The Exeter femoral component continues to function satisfactorily in young patients for up to 17 years after surgery. Cite this article: Bone Joint J 2017;99-B:192-8.
Collapse
Affiliation(s)
- M W J L Schmitz
- Radboud university medical center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - E Bronsema
- Radboud university medical center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - D C J de Kam
- Radboud university medical center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - J W M Gardeniers
- Radboud university medical center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - R P H Veth
- Radboud university medical center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - B W Schreurs
- Radboud university medical center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| |
Collapse
|
21
|
Mukka S, Mellner C, Knutsson B, Sayed-Noor A, Sköldenberg O. Substantially higher prevalence of postoperative peri-prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem. Acta Orthop 2016; 87:257-61. [PMID: 27045318 PMCID: PMC4900095 DOI: 10.3109/17453674.2016.1162898] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Background and purpose - Recent studies have demonstrated a high incidence of postoperative periprosthetic femoral fracture (PPF) in elderly patients treated with 2 commonly used cemented, polished tapered stems. We compared the prevalence and incidence rate of PPF in a consecutive cohort of octagenerians with femoral neck fractures (FNFs) treated with either a collarless, polished tapered (CPT) stem or an anatomic matte stem (Lubinus SP2). Patients and methods - In a multicenter, prospective cohort study, we included 979 hips in patients aged 80 years and above (72% females, median age 86 (80-102) years) with a femoral neck fracture as indication for surgery. 69% of the patients were classified as ASA class 3 or 4. Hip-related complications and repeat surgery were assessed at a median follow-up of 20 (0-24) months postoperatively. Results - 22 hips (2.2%) sustained a PPF at a median of 7 (0-22) months postoperatively; 14 (64%) were Vancouver B2 fractures. 7 of the 22 surgically treated fractures required revision surgery, mainly due to deep infection. The cumulative incidence of PPFs was 3.8% in the CPT group, as compared with 0.2% in the SP2 group (p < 0.001). The risk ratio (RR) was 16 (95% CI: 2-120) using the SP2 group as denominator. Interpretation - The CPT stem was associated with a higher risk of PPF than the SP2 stem. We suggest that the tapered CPT stem should not be used for the treatment of femoral neck fractures in patients over 80 years.
Collapse
Affiliation(s)
- Sebastian Mukka
- Department of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;;,Correspondence:
| | - Carl Mellner
- Department of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;;
| | - Björn Knutsson
- Department of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;;,Department of Surgical Sciences, Section of Orthopedics, Uppsala University, Uppsala;
| | - Arkan Sayed-Noor
- Department of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;;
| | - Olof Sköldenberg
- Department of Orthopedics, Danderyd Hospital and Karolinska Institutet, Stockholm, and Department of Clinical Sciences, Danderyd Hospital, Stockholm, Sweden
| |
Collapse
|
22
|
The effect of isotonic saline on the strength of bone cement during the polymerisation period. Hip Int 2016; 21:238-42. [PMID: 21484740 DOI: 10.5301/hip.2011.6517] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/15/2011] [Indexed: 02/04/2023]
Abstract
It is common practice to irrigate the wound in hip and knee replacement surgery during the working and setting phases of cement polymerisation. We sought to establish whether the addition of normal saline during the various stages of polymerisation would affect bone cement strength. Cement specimens were moulded to the dimensions defined in ISO 5833: 2002 and tested in an electro-mechanical test machine with a calibrated 50 kN load cell at a compression rate of 24 mm/min. The results suggest that the compressive strength of bone cement is not affected by the presence of saline following the initiation of polymerisation. However, saline added to the mix prior to the initiation of polymerisation increased its porosity and significantly decreased its strength. This may explain why vacuum mixing is important as it removes water vapour.
Collapse
|
23
|
Rajakulendran K, Strambi F, Ruggeri R, Field RE. A Cannulated Tri-Tapered Femoral Stem for Total Hip Arthroplasty: Clinical and Radiological Results at Ten Years. J Arthroplasty 2015; 30:1772-6. [PMID: 25956523 DOI: 10.1016/j.arth.2015.04.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Revised: 02/23/2015] [Accepted: 04/18/2015] [Indexed: 02/01/2023] Open
Abstract
We report the ten-year clinical and radiological outcomes of a novel cannulated, tri-tapered femoral stem, used in primary total hip arthroplasty (110 stems in 98 patients). At ten years, two Tri-taper stems had been revised for infection and dislocation. The mean Oxford Hip Score improved from 13.46 pre-operatively, to 37.04. Radiological analysis revealed radiolucent lines in 57 cases, but none exceeded 2 mm thickness. Stem subsidence was identified in 63 cases, with mean distal tip migration of 3.8 mm. Survivorship with revision for aseptic loosening as the end point was 100% at 10 years. Stem survival with revision for any cause was 98.2% (95% CI, 92.9% to 99.5%). The ten-year results of the Tri-taper stem are comparable to other polished, tapered femoral stems.
Collapse
Affiliation(s)
- Karthig Rajakulendran
- The Royal National Orthopaedic Hospital, Stanmore, Middlesex, United Kingdom; The Elective Orthopaedic Centre, Epsom, Surrey, United Kingdom
| | | | | | - Richard E Field
- The Elective Orthopaedic Centre, Epsom, Surrey, United Kingdom; St George's, University of London, Cranmer Terrace, London, United Kingdom
| |
Collapse
|
24
|
Periprosthetic fractures around polished collarless cemented stems: the effect of stem design on fracture pattern. Hip Int 2015; 23:459-64. [PMID: 23813164 DOI: 10.5301/hipint.5000052] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/25/2013] [Indexed: 02/04/2023]
Abstract
BACKGROUND Predictable patterns of periprosthetic fracture have been observed around polished double tapered stems. Finite element studies have suggested that triple-tapered stems cause less cement strain in torsion compared to double-tapered stems. Hence, we hypothesised that the in vitro behaviour of implanted double- and triple-tapered polished stems, like the CPT (Zimmer, Warsaw, USA) or C-Stem (DePuy, Leeds, U.K.) when subjected to pathological torsional loads may cause different patterns of periprosthetic fractures. METHODS Ten double-tapered stems (CPT) and ten triple-tapered stems (C-Stem) were cemented into synthetic femur bones. A constant axial compression load of 100 N and a torsional pre-load of 0.1 N.m were applied using a biaxial testing machine. The distal femur was then loaded in external rotation at 45 degrees until failure. RESULTS Seven of the 10 CPT stems fractured at the level of the stem body while fracturing the cement mantle at the same level. In three of ten of the CPT stems and all ten C-Stems, the synthetic bone fractured at the tip of the prosthesis while the cement mantle remained intact. This was significant for the resulting fracture pattern (P=0.001). There was no significant difference between the groups for either torque (P=0.13) or angle at failure (P=0.49). INTERPRETATION This biomechanical study indicates that the CPT and C-Stem create a different fracture pattern under the same loading condition. The C-Stem (a triple tapered stem) may produce lower strain in torsion to the cement mantle of a cemented THA. However, fractures that do occur may be more difficult to treat than those produced around a stem like the CPT subjected to comparable loading.
Collapse
|
25
|
Brodén C, Mukka S, Muren O, Eisler T, Boden H, Stark A, Sköldenberg O. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem. Acta Orthop 2015; 86:169-74. [PMID: 25280133 PMCID: PMC4404766 DOI: 10.3109/17453674.2014.971388] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Postoperative periprosthetic femoral fracture (PPF) after hip arthroplasty is associated with considerable morbidity and mortality. We assessed the incidence and characteristics of periprosthetic fractures in a consecutive cohort of elderly patients treated with a cemented, collarless, polished and tapered femoral stem (CPT). PATIENTS AND METHODS In this single-center prospective cohort study, we included 1,403 hips in 1,357 patients (mean age 82 (range 52-102) years, 72% women) with primary osteoarthritis (OA) or a femoral neck fracture (FNF) as indication for surgery (367 hips and 1,036 hips, respectively). 64% of patients were ASA class 3 or 4. Hip-related complications and need for repeat surgery were assessed at a mean follow-up time of 4 (1-7) years. A Cox regression analysis was used to evaluate risk factors associated with PPF. RESULTS 47 hips (3.3%) sustained a periprosthetic fracture at median 7 (2-79) months postoperatively; 41 were comminute Vancouver B2 or complex C-type fractures. The fracture rate was 3.8% for FNF patients and 2.2% for OA patients (hazard ratio (HR) = 4; 95% CI: 1.3-12). Patients > 80 years of age also had a higher risk of fracture (HR = 2; 95% CI: 1.1-4.5). INTERPRETATION We found a high incidence of early PPF associated with the CPT stem in this old and frail patient group. A possible explanation may be that the polished tapered stem acts as a wedge, splitting the femur after a direct hip contusion. Our results should be confirmed in larger, registry-based studies, but we advise caution when using this stem for this particular patient group.
Collapse
Affiliation(s)
- Cyrus Brodén
- Department of Orthopedics at Danderyd Hospital and Department of Clinical Sciences at Danderyd Hospital (KIDS), Karolinska Institutet, Stockholm
| | - Sebastian Mukka
- Department of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden.
| | - Olle Muren
- Department of Orthopedics at Danderyd Hospital and Department of Clinical Sciences at Danderyd Hospital (KIDS), Karolinska Institutet, Stockholm
| | - Thomas Eisler
- Department of Orthopedics at Danderyd Hospital and Department of Clinical Sciences at Danderyd Hospital (KIDS), Karolinska Institutet, Stockholm
| | - Henrik Boden
- Department of Orthopedics at Danderyd Hospital and Department of Clinical Sciences at Danderyd Hospital (KIDS), Karolinska Institutet, Stockholm
| | - André Stark
- Department of Orthopedics at Danderyd Hospital and Department of Clinical Sciences at Danderyd Hospital (KIDS), Karolinska Institutet, Stockholm
| | - Olof Sköldenberg
- Department of Orthopedics at Danderyd Hospital and Department of Clinical Sciences at Danderyd Hospital (KIDS), Karolinska Institutet, Stockholm
| |
Collapse
|
26
|
Empirical support for radiographic review: a follow-up study of total hip arthroplasty. Hip Int 2014; 23:80-6. [PMID: 23233185 DOI: 10.5301/hip.2012.9912] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/25/2012] [Indexed: 02/04/2023]
Abstract
Routine post surgery surveillance of total hip arthroplasty (THA) is widely recommended to identify asymptomatic failure but inclusion of an x-ray adds to service costs. Evidence is needed to support orthopaedic opinion in order to identify what should be included in surveillance. An investigation was conducted to establish whether an x-ray is needed in addition to patient reported outcome measures. One hundred and fifty-four THA had been assessed at 3 years and were reviewed again at 6 to 9 years (mid-term) when radiographic signs of deterioration commonly appear. Data were explored for associations between radiographic changes and changes in the participants' Oxford Hip Score, age, EuroQol 5-D score or comorbidities. Hierarchical multiple regression analysis showed that the number of radiographic changes could not be predicted by any of the other variables. This supports the inclusion of an x-ray in THA surveillance and suggests that the state of the THA cannot be determined by the use of patient reported outcome measures alone. This has implications for future arthroplasty surveillance.
Collapse
|
27
|
Stefanovich-Lawbuary NS, Parry MC, Whitehouse MR, Blom AW. Cement in cement revision of the femoral component using a collarless triple taper: a midterm clinical and radiographic assessment. J Arthroplasty 2014; 29:2002-6. [PMID: 24927866 DOI: 10.1016/j.arth.2014.05.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Revised: 04/27/2014] [Accepted: 05/05/2014] [Indexed: 02/01/2023] Open
Abstract
This study describes the midterm clinical and radiological results of the cement in cement technique for the femur using a collarless triple taper. Radiographic assessment was made retrospectively from 44 patients at two time points. Clinical outcomes included the Oxford Hip Score, EQ5D and Self Reported Patient Satisfaction Scale. Implant and patient survival were also recorded. The mean clinical follow up period was 5years 3months and the radiological follow up 2years 10months. The mean OHS was 34, the mean EQ5D 0.814 and the mean SAPS 94. Kaplan-Meier survival with revision, as the end point was 95.2% at 11years with a survivorship of 76.5% with death as the end point. Cement in cement revision using a collarless triple tapered stem demonstrates promising results both clinically and radiologically at midterm follow up.
Collapse
Affiliation(s)
- Natalija S Stefanovich-Lawbuary
- Musculoskeletal Research Unit, University of Bristol, Avon Orthopaedic Centre, Southmead Hospital, Westbury on Trym, Bristol, UK, BS10 5NB
| | - Michael C Parry
- Musculoskeletal Research Unit, University of Bristol, Avon Orthopaedic Centre, Southmead Hospital, Westbury on Trym, Bristol, UK, BS10 5NB
| | - Michael R Whitehouse
- Musculoskeletal Research Unit, University of Bristol, Avon Orthopaedic Centre, Southmead Hospital, Westbury on Trym, Bristol, UK, BS10 5NB
| | - Ashley W Blom
- Musculoskeletal Research Unit, University of Bristol, Avon Orthopaedic Centre, Southmead Hospital, Westbury on Trym, Bristol, UK, BS10 5NB
| |
Collapse
|
28
|
Berstock JR, Whitehouse MR, Piper DC, Eastaugh-Waring SJ, Blom AW. A 5-8 year retrospective follow-up of the C-stem AMT femoral component: patient reported outcomes and survivorship analysis. J Arthroplasty 2014; 29:1753-7. [PMID: 24891001 DOI: 10.1016/j.arth.2014.04.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 04/06/2014] [Accepted: 04/27/2014] [Indexed: 02/01/2023] Open
Abstract
We report midterm functional, radiographic and survivorship data for the cemented, triple taper C-stem AMT femoral component from a consecutive cohort of 415 hip arthroplasties in 386 patients at a non-developer centre. Follow-up ranges were from 60 to 99 months, with a mean of 76 months. 32 hips were lost to follow-up. The median OHS was 40, median SF-12 mental component score (MCS) was 50, and median SF-12 physical component score (PCS) was 39. At 99 months follow up, stem survivorship is 96.9% (95% confidence interval (CI) 82.5-99.5), and construct survivorship is 96.0% (95% CI 84.2-99.0). Adverse events such as calcar fracture, greater trochanter fracture and dislocation were rare at <1%. There have been no revisions for aseptic loosening.
Collapse
Affiliation(s)
- James R Berstock
- University of Bristol Musculoskeletal Research Unit, AOC (Lower Level), Southmead Hospital, Westbury-on-Trym, Bristol, UK
| | - Michael R Whitehouse
- University of Bristol Musculoskeletal Research Unit, AOC (Lower Level), Southmead Hospital, Westbury-on-Trym, Bristol, UK
| | - Danielle C Piper
- University of Bristol Musculoskeletal Research Unit, AOC (Lower Level), Southmead Hospital, Westbury-on-Trym, Bristol, UK
| | - Stephen J Eastaugh-Waring
- University of Bristol Musculoskeletal Research Unit, AOC (Lower Level), Southmead Hospital, Westbury-on-Trym, Bristol, UK
| | - Ashley W Blom
- University of Bristol Musculoskeletal Research Unit, AOC (Lower Level), Southmead Hospital, Westbury-on-Trym, Bristol, UK
| |
Collapse
|
29
|
Hutt J, Hazlerigg A, Aneel A, Epie G, Dabis H, Twyman R, Cobb A. The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs. INTERNATIONAL ORTHOPAEDICS 2014; 38:1131-7. [PMID: 24474088 DOI: 10.1007/s00264-013-2256-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2013] [Accepted: 12/09/2013] [Indexed: 10/25/2022]
Abstract
PURPOSE The optimal design for a cemented femoral stem remains a matter of debate. Over time, the shape, surface finish and collar have all been modified in various ways. A clear consensus has not yet emerged regarding the relative merits of even the most basic design features of the stem. We undertook a prospective randomised trial comparing surface finish and the effect of a collar on cemented femoral component subsidence, survivorship and clinical function. METHODS One hundred and sixty three primary total hip replacement patients were recruited prospectively and randomised to one of four groups to receive a cemented femoral stem with either a matt or polished finish, and with or without a collar. RESULTS At two years, although there was a trend for increased subsidence in the matt collarless group, this was not statistically significant (p = 0.18). At a mean of 10.1 years follow-up, WOMAC scores for the surviving implants were good, (Range of means 89-93) without significant differences. Using revision or radiographic loosening as the endpoint, survivorship of the entire cohort was 93 % at 11 yrs, (CI 87-97 %). There were no significant differences in survivorship between the two groups with polished stems or the two groups with matt stems. A comparison of the two collarless stems demonstrated a statistically significant difference in survivorship between polished (100 %) and matt (88 %) finishes (p = 0.02). CONCLUSIONS In the presence of a collar, surface finish did not significantly affect survivorship or function. Between the two collarless groups a polished surface conferred an improved survivorship.
Collapse
Affiliation(s)
- Jonathan Hutt
- Department of Trauma and Orthopaedics, Epsom General Hospital, Dorking Road, Epsom, Surrey, KT18 7EG, UK,
| | | | | | | | | | | | | |
Collapse
|
30
|
Primary total hip arthroplasty with a proximally HA-coated titanium femoral component: results at 10–15-year follow-up. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2014; 24:1211-5. [DOI: 10.1007/s00590-013-1405-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2013] [Accepted: 12/27/2013] [Indexed: 01/25/2023]
|
31
|
Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up. INTERNATIONAL ORTHOPAEDICS 2013; 38:717-24. [PMID: 24352821 DOI: 10.1007/s00264-013-2186-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Accepted: 11/03/2013] [Indexed: 10/25/2022]
Abstract
PURPOSE The aim of this study was to determine outcomes of total hip replacement (THR) with the Lemania cemented femoral stem. METHODS A total of 78 THR patients were followed and compared to 17 "fit", healthy, elderly and 72 "frail" elderly subjects without THR, using clinical outcome measures and a portable, in-field gait analysis device at five and ten years follow-up. RESULTS Forty-one patients (53%), mean age 83.4 years, available at ten years follow-up, reported very good to excellent satisfaction. Mean Harris Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were 81.2 and 10.5 points, respectively, with excellent radiological preservation of proximal femur bone stock. Spatial and temporal gait parameters were close to the fit group and better than the frail group. CONCLUSIONS Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR. Gait analysis confirmed good walking performance in a real-life environment.
Collapse
|
32
|
Dou Y, Zhou Y, Tang Q, Yang D, Liu J. Leg-length discrepancy after revision hip arthroplasty: are modular stems superior? J Arthroplasty 2013; 28:676-9. [PMID: 23142440 DOI: 10.1016/j.arth.2012.08.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2012] [Revised: 07/07/2012] [Accepted: 08/08/2012] [Indexed: 02/01/2023] Open
Abstract
We retrospectively reviewed data for 79 consecutive patients who underwent revision hip arthroplasty using cementless femoral stems at our center between September 2008 and November 2010. Two cohorts were included, one using MP (modular) femoral stems and the other using Wagner (monoblock) femoral stems. We assessed leg-length discrepancy (LLD) before and after revision and compared the occurrence of leg-length inequality between the 2 cohorts. We found that the incidence of LLD was high in revision hip arthroplasty and that leg shortening was more common than lengthening. Both acetabular and femoral sides contributed to postoperative LLD. Appropriate placement of the femoral components was most critical in adjusting LLD. We also found that compared with monoblock stems, modular stems made adjustment of postoperative leg length easier.
Collapse
Affiliation(s)
- Yong Dou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | | | | | | | | |
Collapse
|
33
|
Howie DW, Costi K, McGee MA, Standen A, Solomon LB. Femoral bone is preserved using cemented polished stems in young patients. Clin Orthop Relat Res 2012; 470:3024-31. [PMID: 22528375 PMCID: PMC3462866 DOI: 10.1007/s11999-012-2327-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Techniques that ensure femoral bone preservation after primary THA are important in younger patients who are likely to undergo revision surgery. QUESTIONS/PURPOSES We examined femoral stem survival, bone deficiency at revision arthroplasty, and radiographic bone loss in hips implanted with a cemented polished double-taper stem in a cohort of patients younger than 55 years. METHODS We reviewed 197 hips (median patient age, 47 years; range, 16-54 years) after a minimum followup of 2 years (median, 7 years; range, 2-19 years) since primary THA. Clinically, we determined survival to major and minor stem revision and cases of bone deficiency requiring a long stem or impaction bone grafting or created by the need for femoral osteotomy at revision arthroplasty. Radiographically, we assessed stem loosening, femoral osteolysis, and femoral bone deficiency. RESULTS Stem survival to major revision for aseptic loosening was 100% at 13 years and for any reason was 97% (95% CI, 93-100%). At revision of seven stems, a long stem was used in one hip, a total femoral replacement in one hip and impaction bone grafting in one hip. No femoral osteotomies were required. Bone was preserved in four hips by cement-within-cement stem exchange. No stems were radiographically loose. Proximal osteolysis was present in 11% of femurs. Femoral bone deficiency was graded as Paprosky Type I (97%) or II (3%) and Endo-Klinik Grade 0 (79%) or I (21%). CONCLUSIONS Cemented polished taper stems have high survival at 13 years in young patients and enable femoral bone preservation for subsequent revision. LEVEL OF EVIDENCE Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Donald W. Howie
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, L4 Bice Building, North Terrace, Adelaide, SA 5000 Australia ,Discipline of Orthopaedics and Trauma, School of Medicine, University of Adelaide, Adelaide, Australia
| | - Kerry Costi
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, L4 Bice Building, North Terrace, Adelaide, SA 5000 Australia
| | - Margaret A. McGee
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, L4 Bice Building, North Terrace, Adelaide, SA 5000 Australia ,Discipline of Orthopaedics and Trauma, School of Medicine, University of Adelaide, Adelaide, Australia
| | - Angela Standen
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, L4 Bice Building, North Terrace, Adelaide, SA 5000 Australia
| | - Lucian B. Solomon
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, L4 Bice Building, North Terrace, Adelaide, SA 5000 Australia ,Discipline of Orthopaedics and Trauma, School of Medicine, University of Adelaide, Adelaide, Australia
| |
Collapse
|
34
|
Burston BJ, Barnett AJ, Amirfeyz R, Yates PJ, Bannister GC. Clinical and radiological results of the collarless polished tapered stem at 15 years follow-up. ACTA ACUST UNITED AC 2012; 94:889-94. [PMID: 22733941 DOI: 10.1302/0301-620x.94b7.28799] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21 patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001). The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation. Its results are consistent with other polished tapered stem designs.
Collapse
Affiliation(s)
- B J Burston
- Avon Orthopaedic Centre, Westbury-on-Trym, Bristol BS10 5NB, UK.
| | | | | | | | | |
Collapse
|
35
|
Malviya A, Ramaskandhan JR, Bowman R, Hashmi M, Holland JP, Kometa S, Lingard E. What advantage is there to be gained using large modular metal-on-metal bearings in routine primary hip replacement? ACTA ACUST UNITED AC 2011; 93:1602-9. [DOI: 10.1302/0301-620x.93b12.27533] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The aim of this study was to investigate the possible benefit of large-head metal-on-metal bearing on a stem for primary hip replacement compared with a 28 mm diameter conventional metal-on-polyethylene bearing in a prospective randomised controlled trial. We investigated cemented stem behaviour between these two different bearings using Einzel-Bild-Röntgen-Analyse, clinical and patient reported measures (Harris hip score, Western Ontario and McMaster Universities osteoarthritis index, Short Form-36 and satisfaction) and whole blood metal ion levels at two years. A power study indicated that 50 hips were needed in each group to detect subsidence of > 5 mm at two years with a p-value of < 0.05. Significant improvement (p < 0.001) was found in the mean clinical and patient reported outcomes at two years for both groups. Comparison of outcomes between the groups at two years showed no statistically significant difference for mean stem migration, clinical and patient reported outcomes; except overall patient satisfaction which was higher for metal-on-metal group (p = 0.05). Metal ion levels were raised above the Medicines and Healthcare products Regulatory Agency advised safety level (7 µg per litre) in 20% of the metal-on-metal group and in one patient in metal-on-polyethylene group (who had a metal-on-metal implant on the contralateral side). Two patients in the metal-on-metal group were revised, one for pseudotumour and one for peri-prosthetic fracture. Use of large modular heads is associated with a risk of raised whole blood metal ion levels despite using a proven bearing from resurfacing. The head-neck junction or excess stem micromotion are possibly the weak links warranting further research.
Collapse
Affiliation(s)
- A. Malviya
- Wansbeck General Hospital, Northumbria
NHS Trust, Woodhorne Lane, Ashington NE63
9JJ, UK
| | - J. R. Ramaskandhan
- Freeman Hospital, Department
of Orthopaedics, Freeman Road, High
Heaton, Newcastle Upon Tyne, Tyne
and Wear NE7 7DN, UK
| | | | | | - J. P. Holland
- Freeman Hospital, Department
of Orthopaedics, Freeman Road, High
Heaton, Newcastle Upon Tyne, Tyne
and Wear NE7 7DN, UK
| | - S. Kometa
- Newcastle University, Statistics
ISS, Claremont Tower, Claremont
Road, Newcastle Upon Tyne NE1 7RU, UK
| | - E. Lingard
- Northern Deanery, Waterfront
4, Goldcrest Way, Newburn
Riverside, Newcastle Upon Tyne NE15 8NY, UK
| |
Collapse
|
36
|
Howie DW, Callary SA, McGee MA, Russell NC, Solomon LB. Reduced femoral component subsidence with improved impaction grafting at revision hip arthroplasty. Clin Orthop Relat Res 2010; 468:3314-21. [PMID: 20680531 PMCID: PMC2974885 DOI: 10.1007/s11999-010-1484-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Despite stem subsidence being a major complication of femoral impaction bone grafting in cemented revision hip arthroplasty, few studies have distinguished subsidence at the prosthesis-cement interface from that at the cement-bone interface. It is unknown how technique developments intended to improve the procedure influence stability of the stem. QUESTIONS/PURPOSES We used a sensitive technique to measure subsidence of a cemented polished collarless double-taper stem at each interface after femoral impaction grafting and compared subsidence, radiographic loosening, complications, and reoperations over three series of hips defined by technique developments. PATIENTS AND METHODS Three series were defined: Series 1 (n = 23, irradiated allograft), Series 2 (n = 12, double-washed, size-profiled graft, nonirradiated bone, long stems as required), and Series 3 (n = 21, modular tamps). Stem subsidence was analyzed with Ein Bild Röntgen Analyse software. Radiographic loosening, complications, and reoperations were also determined. RESULTS The median subsidence at 12 months for Series 1, 2, and 3 were 2.1, 0.5, and 0.7 mm at the prosthesis-cement interface and 1.3, 0.1, and 0.1 mm at the cement-bone interface. There were two postoperative Vancouver B periprosthetic fractures in Series 1, four hips were revised for loosening in Series 1, and there were no fractures or loosening in Series 2 and 3 at minimum 2 years' followup. There were no surviving hips radiographically classified as possibly or probably loose. CONCLUSIONS Evolution in techniques of femoral impaction grafting in this study were associated with reduced subsidence of the stem at both the prosthesis-cement interface and cement-bone interface when compared to the original series. Concurrent with reduced stem subsidence was the absence of periprosthetic fracture, radiographic loosening, and complications requiring rerevision.
Collapse
Affiliation(s)
- D. W. Howie
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, North Terrace, Adelaide, SA 5000 Australia ,Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, SA Australia
| | - S. A. Callary
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, North Terrace, Adelaide, SA 5000 Australia ,Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, SA Australia
| | - M. A. McGee
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, North Terrace, Adelaide, SA 5000 Australia ,Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, SA Australia
| | - N. C. Russell
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, North Terrace, Adelaide, SA 5000 Australia
| | - L. B. Solomon
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, North Terrace, Adelaide, SA 5000 Australia ,Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, SA Australia
| |
Collapse
|
37
|
Patel PD, Klika AK, Murray TG, Elsharkawy KA, Krebs VE, Barsoum WK. Influence of technique with distally fixed modular stems in revision total hip arthroplasty. J Arthroplasty 2010; 25:926-31. [PMID: 19729272 DOI: 10.1016/j.arth.2009.07.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2008] [Accepted: 07/07/2009] [Indexed: 02/01/2023] Open
Abstract
Distally fixed modular implants have seen a recent increase in use, to manage proximal femoral bone loss often encountered during revision total hip arthroplasty (THA). Forty-three distally fixed modular stems implanted at our institution between 1999 and 2006 were clinically and radiographically reviewed. These patients had either a minimum 2-year follow-up (average, 2.4 years; range, 2-5.6 years) or failure (ie, explant or rerevision required). Eleven stems subsided, and 4 were rerevised (n = 4), for a rate of 9.3%. All revised stems were radiographically undersized, emphasizing the importance of the technique. Although being a valuable option in revision THA, these stems are not free of complications. The high rate of subsidence encountered in our early experience shows that there is a learning curve. This complication is preventable by avoiding undersizing.
Collapse
Affiliation(s)
- Preetesh D Patel
- Department of Orthopedic Surgery, Cleveland Clinic Florida, Weston, Florida, USA
| | | | | | | | | | | |
Collapse
|
38
|
Burston BJ, Yates PJ, Hook S, Moulder E, Whitley E, Bannister GC. Cemented polished tapered stems in patients less than 50 years of age: a minimum 10-year follow-up. J Arthroplasty 2010; 25:692-9. [PMID: 19577886 DOI: 10.1016/j.arth.2009.05.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2008] [Accepted: 05/08/2009] [Indexed: 02/01/2023] Open
Abstract
We report the outcome of 58 consecutive polished tapered stems in 47 patients younger than 50 years, with a minimum of 10 years of follow-up. No stems were revised for aseptic loosening or osteolysis. The Harris hip scores were good or excellent in 76% of the patients. There was excellent preservation of proximal bone. Despite higher patient weight and frequent previous surgery, the outcome of polished tapered stems in patients younger than 50 years is comparable to the general population undergoing total hip arthroplasty and superior to other non-polished tapered stem designs in young patients. Cup wear and cup failure were significantly worse in this group, with a higher incidence of periarticular osteolysis. Polished tapered stem designs are the benchmark for comparison to other arthroplasty options in young patients.
Collapse
Affiliation(s)
- Ben J Burston
- Avon Orthopaedic Centre, Southmead Hospital, Bristol
| | | | | | | | | | | |
Collapse
|
39
|
McCalden RW, Charron KD, Yuan X, Bourne RB, Naudie DD, MacDonald SJ. Randomised controlled trial comparing early migration of two collarless polished cemented stems using radiostereometric analysis. ACTA ACUST UNITED AC 2010; 92:935-40. [DOI: 10.1302/0301-620x.92b7.24462] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised controlled trial in which 17 patients received a dedicated radiostereometric CPCS stem and 17 a radiostereometric Exeter stem. No difference was found in any of the outcome measures pre-operatively or post-operatively between groups. At two years, the mean subsidence for the CPCS stem was nearly half that seen for the Exeter stem (0.77 mm (−0.943 to 1.77) and 1.25 mm (0.719 to 1.625), respectively; p = 0.032). In contrast, the mean internal rotation of the CPCS stem was approximately twice that of the Exeter (1.61° (−1.07° to 4.33°) and 0.59° (0.97° to 1.64°), respectively; p = 0.048). Other migration patterns were not significantly different between the stems. The subtle differences in designs may explain the different patterns of migration. Comparable migration with the Exeter stem suggests that the CPCS design will perform well in the long term.
Collapse
Affiliation(s)
- R. W. McCalden
- London Health Sciences Centre, University of Western Ontario, 339 Windermere Road, London, Ontario, Canada N6A 5A5
| | - K. D. Charron
- London Health Sciences Centre, University of Western Ontario, 339 Windermere Road, London, Ontario, Canada N6A 5A5
| | - X Yuan
- Robarts Research Institute, University of Western Ontario, P. O. Box 5015, 100 Perth Drive, London, Ontario, Canada N6A 5K8
| | - R. B. Bourne
- London Health Sciences Centre, University of Western Ontario, 339 Windermere Road, London, Ontario, Canada N6A 5A5
| | - D. D. Naudie
- London Health Sciences Centre, University of Western Ontario, 339 Windermere Road, London, Ontario, Canada N6A 5A5
| | - S. J. MacDonald
- London Health Sciences Centre, University of Western Ontario, 339 Windermere Road, London, Ontario, Canada N6A 5A5
| |
Collapse
|
40
|
Pluot E, Davis ET, Revell M, Davies AM, James SLJ. Hip arthroplasty. Part 2: normal and abnormal radiographic findings. Clin Radiol 2009; 64:961-71. [PMID: 19748001 DOI: 10.1016/j.crad.2009.05.002] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2009] [Revised: 05/08/2009] [Accepted: 05/11/2009] [Indexed: 02/07/2023]
Abstract
This review addresses the normal and abnormal radiographic findings that can be encountered during the follow-up of patients with total hip arthroplasty (THA). The relative significance of different patterns of radiolucency, bone sclerosis, and component position is discussed. The normal or pathological significance of these findings is correlated with design, surface, and fixation of the prosthetic components. It is essential to have a good knowledge of expected and unexpected radiological evolution according to the different types of prostheses. This paper emphasizes the importance of serial studies compared with early postoperative radiographs during follow-up in order to report accurately any sign of prosthetic failure and trigger prompt specialist referral. Basic technical guidelines and schedule recommendations for radiological follow-up are summarized.
Collapse
Affiliation(s)
- E Pluot
- Department of Radiology, The Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, UK
| | | | | | | | | |
Collapse
|
41
|
Ollivere B, Darrah C, Brankin RC, Donnell ST, Walton NP. The continued value of clinical and radiological surveillance. ACTA ACUST UNITED AC 2009; 91:720-4. [DOI: 10.1302/0301-620x.91b6.21417] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We report the follow-up at 12 years of the use of the Elite Plus total hip replacement (THR). We have previously reported the results at a mean of 6.4 years. Of the 217 patients (234 THRs), 83 had died and nine had been lost to follow-up. The patients were reviewed radiologically and clinically using the Oxford hip score. Of the 234 THRs, 19 (8.1%) had required a revision by the final follow-up in all but one for aseptic loosening. Survivorship analysis for revision showed a survival of 93.9% (95% confidence interval (CI) 89.2 to 96.5) at ten years, and of 88.0% (95% CI 81.8 to 92.3) at 12 years. At the final follow-up survival analysis showed that 37% (95% CI 37.3 to 44.7) of the prostheses had either failed radiologically or had been revised. Patients with a radiologically loose femoral component had a significantly poorer Oxford hip score than those with a well-fixed component (p = 0.03). Radiological loosening at 6.4 years was predictive of failure at 12 years. Medium-term radiographs and clinical scores should be included in the surveillance of THR to give an early indication of the performance of specific implants.
Collapse
Affiliation(s)
- B. Ollivere
- Institute of Orthopaedics Norfolk & Norwich University Hospital, Colney Lane, Colney, Norwich NR4 7UY, UK
| | - C. Darrah
- Institute of Orthopaedics Norfolk & Norwich University Hospital, Colney Lane, Colney, Norwich NR4 7UY, UK
| | - R. C. Brankin
- Institute of Orthopaedics Norfolk & Norwich University Hospital, Colney Lane, Colney, Norwich NR4 7UY, UK
| | - S. T. Donnell
- Institute of Orthopaedics Norfolk & Norwich University Hospital, Colney Lane, Colney, Norwich NR4 7UY, UK
| | - N. P. Walton
- Institute of Orthopaedics Norfolk & Norwich University Hospital, Colney Lane, Colney, Norwich NR4 7UY, UK
| |
Collapse
|