She Z, Yang F, Zhang S, Yang L, Wang X. A novel intramedullary nail design of intertrochanteric fracture fixation improved by proximal femoral nail antirotation. Comput Methods Biomech Biomed Engin 2023:1-11. [PMID: 38006389 DOI: 10.1080/10255842.2023.2286917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 11/18/2023] [Indexed: 11/27/2023]
Abstract
A proper and reliable fracture fixation is important for fracture healing. The proximal femoral intramedullary nail (IN), such as proximal femoral nail anti-rotation (PFNA) or Gamma nail, is widely used for intertrochanteric fracture fixation. However, it still suffers considerable stress concentrations, especially at the junction between the nail and the blade or lag screw. In this study, we propose a novel intramedullary nail design to enhance the intramedullary nail integrity by introducing a bolt screw to form a stable triangular structure composed of the nail, the lag screw, and the bolt screw (PFTN, Proximal femoral triangle nail). Systematic finite element numerical simulations were carried out to compare the biomechanical performances of PFTN and PFNA under both static and dynamic loads during the postures of ascending and descending stairs. The simulation results highlight the advantages of the proposed PFTN design with lower stresses, less stress concentration, and higher structure stability.
Collapse
Affiliation(s)
- Ze She
- School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai, China
| | - Fan Yang
- School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai, China
| | - Siyuan Zhang
- School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai, China
| | - Liang Yang
- Tongji Hospital of Tongji University, Shanghai, China
- School of Medicine, Tongji University, Shanghai, China
| | - Xin Wang
- Tongji Hospital of Tongji University, Shanghai, China
- School of Medicine, Tongji University, Shanghai, China
| |
Collapse
|
2
|
Muriuki MG, Sonn KA, Brinkmann EJ, Blank KR, Havey RM, Patwardhan AG, Bernstein M. Comparison of the biomechanical stability of transverse and oblique screw trajectories in retrograde intramedullary nailing of supracondylar femur fractures. Clin Biomech (Bristol, Avon) 2022; 100:105795. [PMID: 36252452 DOI: 10.1016/j.clinbiomech.2022.105795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 09/22/2022] [Accepted: 10/06/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND The goal was to determine the effect of addition of oblique trajectory distal interlock screws to a retrograde intramedullary femoral nail on implant stability (stiffness), cycles to failure and mode of failure. The hypothesis was that addition of oblique screws would increase implant stability and number of loading cycles to failure. METHODS Eight matched pairs were tested; one femur implanted with a femoral nail with only transverse distal interlock screws and the other with transverse and oblique interlock screws. Axial compressive load was applied to the femoral head and the gluteal tendon was tensioned vertically to simulate standing or at 45° to the sagittal plane to simulate stair climbing. Loads were cycled to increasing amplitude until failure of fixation (10 mm displacement or 10° rotation). FINDINGS In simulated standing, oblique screw specimen had greater sagittal bending (bowing) than transverse only specimen. Transverse (axial) plane motion was higher in simulated stair climbing in oblique screw specimen. Oblique screw specimen had higher sagittal plane translation at 600 N of load. At 300 N, oblique screw specimen had lower internal-external rotation than transverse only specimen. A larger number of cycles to failure were observed in four oblique screw of seven paired specimen. Failure (10 mm or 10 degrees of motion) was only achieved during simulated stair climbing. INTERPRETATION Our hypothesis that adding oblique screws improves fixation was rejected. Activities of daily living other than standing may constitute a challenge to fracture fixation; fixation failure occurred at lower loads in simulated stair climbing than standing.
Collapse
Affiliation(s)
- Muturi G Muriuki
- Musculoskeletal Biomechanics Laboratory, Edward Hines Jr. VA Hospital. P.O. Box 5000 (151L), Hines, IL 60141, USA.
| | - Kevin A Sonn
- Department of Orthopaedic Surgery and Rehabilitation, Loyola University Medical Center, 2160 S. 1(st) Avenue, Maywood, IL 60153, USA
| | - Elyse J Brinkmann
- Department of Orthopaedic Surgery and Rehabilitation, Loyola University Medical Center, 2160 S. 1(st) Avenue, Maywood, IL 60153, USA
| | - Kenneth R Blank
- Musculoskeletal Biomechanics Laboratory, Edward Hines Jr. VA Hospital. P.O. Box 5000 (151L), Hines, IL 60141, USA
| | - Robert M Havey
- Musculoskeletal Biomechanics Laboratory, Edward Hines Jr. VA Hospital. P.O. Box 5000 (151L), Hines, IL 60141, USA
| | - Avinash G Patwardhan
- Musculoskeletal Biomechanics Laboratory, Edward Hines Jr. VA Hospital. P.O. Box 5000 (151L), Hines, IL 60141, USA; Department of Orthopaedic Surgery and Rehabilitation, Loyola University Medical Center, 2160 S. 1(st) Avenue, Maywood, IL 60153, USA
| | - Mitchell Bernstein
- Department of Orthopaedic Surgery and Rehabilitation, Loyola University Medical Center, 2160 S. 1(st) Avenue, Maywood, IL 60153, USA
| |
Collapse
|
3
|
Wilson JL, Squires M, McHugh M, Ahn J, Perdue A, Hake M. The geriatric distal femur fracture: nail, plate or both? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2022:10.1007/s00590-022-03337-5. [PMID: 35895117 DOI: 10.1007/s00590-022-03337-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
Surgical fixation of distal femur fractures in geriatric patients is an evolving topic. Unlike hip fractures, treatment strategies for distal femur fractures are ill-defined and lack substantive high-quality evidence. With an increasing incidence and an association with significant morbidity and mortality, it is essential to understand existing treatment options and their supporting evidence. Current fixation methods include the use of either retrograde intramedullary nails, or plate and screw constructs. Due to the variability in fracture patterns, the unique anatomy of the distal femur, and the presence or absence or pre-existing implants, decision-making as to which method to use can be challenging. Recent literature has sought to describe the advantages and disadvantages of each, however, there is currently no consensus on a standard of care, and little randomized evidence is available that directly compares intramedullary nails with plating. Future randomized studies comparing intramedullary nails with plating constructs are necessary in order to develop a standard of care based on injury characteristics.
Collapse
Affiliation(s)
- Jenna L Wilson
- Orthopaedic Surgery Department, 1500 East Medical Center Drive, TC2912, SPC 5328, Ann Arbor, MI, 48109, USA.
| | - Mathieu Squires
- Orthopaedic Surgery Department, 1500 East Medical Center Drive, TC2912, SPC 5328, Ann Arbor, MI, 48109, USA
| | - Michael McHugh
- Orthopaedic Surgery Department, 1500 East Medical Center Drive, TC2912, SPC 5328, Ann Arbor, MI, 48109, USA
| | - Jaimo Ahn
- Orthopaedic Surgery Department, 1500 East Medical Center Drive, TC2912, SPC 5328, Ann Arbor, MI, 48109, USA
| | - Aaron Perdue
- Orthopaedic Surgery Department, 1500 East Medical Center Drive, TC2912, SPC 5328, Ann Arbor, MI, 48109, USA
| | - Mark Hake
- Orthopaedic Surgery Department, 1500 East Medical Center Drive, TC2912, SPC 5328, Ann Arbor, MI, 48109, USA
| |
Collapse
|
4
|
Nail diameter significantly impacts stability in combined plate-nail constructs used for fixation of supracondylar distal femur fractures. OTA Int 2022; 5:e174. [PMID: 35187412 PMCID: PMC8846389 DOI: 10.1097/oi9.0000000000000174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 11/17/2021] [Accepted: 12/10/2021] [Indexed: 11/30/2022]
Abstract
Objectives: Plate-nail (PN) combinations have been described for fixation of supracondylar distal femur fractures. Small diameter retrograde intramedullary nails (rIMN) are commonly used. The purpose of this study was to investigate the effect of nail diameter on construct stability. We hypothesized that a larger diameter rIMN would not significantly change the stiffness of the PN construct when tested in torsional or axial loading. Methods: Twelve synthetic osteoporotic femurs were used to compare nail diameters in an extraarticular supracondylar distal femur fracture model (Orthopaedic Trauma Association/Arbeitsgemeinschaft für Osteosynthesefragen type 33-A3). Constructs were fixed with a 12-hole 4.5 mm pre-contoured lateral distal femoral locking plate combined with either a 9 mm (n = 6) or an 11 mm (n = 6) retrograde intramedullary nail (rIMN). Specimens were cyclically loaded in torsion and axial compression. The primary outcome was construct stiffness, calculated using the average slope of the force-displacement curves. Results: The 11 mm PN construct was approximately 1.6 times stiffer than the 9 mm PN construct averaged across all torsional loads (2.39 +/− 0.41 Nm/deg vs 1.44 +/− 0.17 Nm/deg) and approximately 1.3 times stiffer than the 9 mm PN construct averaged across all axial loads (506.84 +/− 44.50 N/mm vs 376.77 +/− 37.65 N/mm). There were no construct failures. Conclusions: In this biomechanical model, nail diameter had a significant effect on both torsional and axial stiffness in PN constructs. While the use of smaller diameter rIMNs has been proposed to allow for easier placement of implants, the effect on overall construct stiffness should be considered in the context of the patient, their fracture and desired postoperative weight bearing recommendations. Level of Evidence: N/A
Collapse
|
5
|
Bonnomet F, Favreau H, Bonnevialle P, Adam P, Ehlinger M. Interimplant femoral fractures. Orthop Traumatol Surg Res 2022; 108:103117. [PMID: 34666198 DOI: 10.1016/j.otsr.2021.103117] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 03/20/2021] [Accepted: 03/22/2021] [Indexed: 02/03/2023]
Abstract
The number of hip or knee arthroplasties, and internal fixations of the proximal and distal femur, is increasing in proportion to the growing and ageing population, whose life expectancy is lengthening. Thus, fractures of the femur between proximal and distal implants, although rare, are becoming more frequent. Women over the age of 70, with fragile bones and whose ends of the two implants are close to each other ("kissing implants") are particularly vulnerable to them. Reliable and reproducible fracture classifications exist when it comes to 2 prostheses, but they are less well established in the presence of one, or even two, non-prosthetic implants. Their treatment is difficult and must consider the possibility of fracture consolidation while ensuring or restoring the stability and role of the implants. Whether it is the main element of treatment or a complement to prosthesis revision, locked plating forms the basis of the treatment but it must be rigorous, considering that failures are mainly the result of technical errors. Other more invasive treatments (total femoral arthroplasty, cortical sleeves) are offered more rarely if consolidation appears compromised.
Collapse
Affiliation(s)
- François Bonnomet
- Service d'orthopédie et de traumatologie, hôpital de Hautepierre, hôpitaux universitaires de Strasbourg, 67098 Strasbourg, France.
| | - Henri Favreau
- Service d'orthopédie et de traumatologie, hôpital de Hautepierre, hôpitaux universitaires de Strasbourg, 67098 Strasbourg, France
| | - Paul Bonnevialle
- Département universitaire d'orthopédie traumatologie, hôpital Paul-Riquet, place Baylac, 31052 Toulouse, France
| | - Philippe Adam
- Service d'orthopédie et de traumatologie, hôpital de Hautepierre, hôpitaux universitaires de Strasbourg, 67098 Strasbourg, France
| | - Matthieu Ehlinger
- Service d'orthopédie et de traumatologie, hôpital de Hautepierre, hôpitaux universitaires de Strasbourg, 67098 Strasbourg, France
| |
Collapse
|
6
|
Nam DJ, Kim MS, Kim TH, Kim MW, Kweon SH. Fractures of the distal femur in elderly patients: retrospective analysis of a case series treated with single or double plate. J Orthop Surg Res 2022; 17:55. [PMID: 35093125 PMCID: PMC8800239 DOI: 10.1186/s13018-022-02944-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 01/20/2022] [Indexed: 11/10/2022] Open
Abstract
Introduction We evaluated the radiologic and clinical outcomes of a lateral incision single plate with and a single-incision double plating in elderly patients with osteoporotic distal femoral fractures. Materials and methods We performed a retrospective study of 82 cases of distal femoral fractures from May 2004 to June 2018. Group A consisted of 42 patients who underwent single-plate fixation. Group B consisted of 40 patients who underwent double-plate fixation. The mean patient age was 77 years (67–87 years) and 76 years (64–86 years) in groups A and B, respectively. All patients were evaluated for procedure duration, time to union, range of knee motion, Lysholm knee score, and presence of complications. Results The average procedure time was 81 min (66–92 min) and 110 min (95–120 min) in groups A and B, respectively (p = 0.33). One case in group B required bone grafting after 5 months. The average time to union was 14 weeks (9–19 weeks) and 12.2 weeks (8–19 weeks) (p = 0.63), and the mean range of knee motion was 105° (90–125°) and 110.7° (90°–130°) (p = 0.37) in groups A and B, respectively. There was no significant statistical difference between the two groups in the Lysholm knee score (p = 0.44) and knee society score (p = 0.53). Conclusion The clinical and radiological outcomes were similar in the 2 groups. In elderly patients, double plate fixation for distal femoral fractures is an useful method for several advantages such as adequate exposure, easy manipulation, anatomical reduction and stable fixation.
Collapse
|
7
|
Meccariello L, Bisaccia M, Ronga M, Falzarano G, Caraffa A, Rinonapoli G, Grubor P, Pace V, Rollo G. Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes. J Orthop Traumatol 2021; 22:33. [PMID: 34350532 PMCID: PMC8339178 DOI: 10.1186/s10195-021-00593-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Accepted: 07/24/2021] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Distal third femoral shaft fractures are characterized by increasing incidence and complexity and are still considered a challenging problem (high morbidity and mortality). No consensus on best surgical option has been achieved. This study aims to investigate radiographic, mineral bone densitometry and clinical outcomes of locking retrograde intramedullary (LRN) nailing, non-locking retrograde intramedullary nailing and anatomical locking plate to surgically treat distal third femoral shaft fractures in young adults. Our hypothesis was that there is no significant statistical difference among the surgical options in terms of results (radiographic, bone densitometry and outcomes assessment). METHODS Retrospective study: 90 patients divided into three groups (group 1 LRN, group 2 NLRN, group 3 plating). Average age was respectively 42.67 (± 18.32), 44.27 (± 15.11) and 42.84 (± 18.32) years. Sex ratio F:M was respectively 2.75, 2.33 and 2.00. AO Classification, KOOS, NUSS and RUSH score, VAS, DEXA scans and plain radiographs were used. Evaluation endpoint: 12 months after surgery. RESULTS There were no statistical differences in terms of surgery time, transfusions, and wound healing. Results were similar with regard to average time of bone healing, RUSH scores, VAS, KOOS, regression between RUSH and VAS, average correlation clinical-radiographic results and patients outcomes. CONCLUSIONS Our results showed no statistical difference in the use of LNR, NLNR and plating for treatment of distal third femur shaft fractures in terms of radiographic, bone densitometry and clinical outcomes. Good subjective and objective results are provided by all three techniques. The choice among the studied techniques must be based on surgeons' experience, indications and subjective patients' aspects. The absence of relevant similar data in the published literature does not allow definitive validation (or rejection) of our hypothesis. A more powered study with a bigger cohort is needed for definitive validation.
Collapse
Affiliation(s)
- Luigi Meccariello
- Department of Orthopedics and Traumatology, AORN San Pio, Via Cupa dell'Angelo, Block: Moscati Floor:2, 82100, Benevento, Italy.
| | - Michele Bisaccia
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
| | - Mario Ronga
- Orthopaedic and Trauma Operative Unit, Department of Biomedical and Dental Sciences and Morpho-Functional Imaging, University of Messina, University Hospital G. Martino, Messina, Italy
| | - Gabriele Falzarano
- Department of Orthopedics and Traumatology, Azienda Ospedaliera "Gaetano Rummo", Benevento, Italy
| | - Auro Caraffa
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
| | - Giuseppe Rinonapoli
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
| | - Predrag Grubor
- School of Medicine, University of Banja Luka, Banja Luka, Bosnia and Herzegovina
| | - Valerio Pace
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
- Orthopaedic and Trauma Operative Unit, Department of Biomedical and Dental Sciences and Morpho-Functional Imaging, University of Messina, University Hospital G. Martino, Messina, Italy
- Department of Orthopedics and Traumatology, Azienda Ospedaliera "Gaetano Rummo", Benevento, Italy
- School of Medicine, University of Banja Luka, Banja Luka, Bosnia and Herzegovina
- The Royal National Orthopaedic Hospital, Stanmore, London, UK
| | - Giuseppe Rollo
- Department of Orthopedics and Traumatology, Vito Fazzi Hospital, Lecce, Italy
| |
Collapse
|
8
|
Albareda-Albareda J, Gabarre-Raso S, Rosell-Pradas J, Puértolas-Broto S, Ibarz-Montaner E, Redondo-Trasobares B, Gómez-Vallejo J, Blanco-Rubio N, Sánchez-Gimeno M, Herrera-Rodríguez A, Gracia-Villa L. Biomechanical behavior of retrograde intramedullary nails in distal femoral fractures. Injury 2021; 52 Suppl 4:S76-S86. [PMID: 33642084 DOI: 10.1016/j.injury.2021.01.052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Accepted: 01/25/2021] [Indexed: 02/02/2023]
Abstract
Fractures of the distal femur affect three different groups of individuals: younger people suffering high-energy trauma, elderly people with fragile bones and people with periprosthetic fractures around previous total knee arthroplasty. Main indications of intramedullary nailing are for supracondylar fractures type A or type C of the AO classification. The main objective of the present work is to analyze, by means of FE simulation, the influence of retrograde nail length, considering different blocking configurations and fracture gaps, on the biomechanical behavior of supracondylar fractures of A type. A three dimensional (3D) finite element model of the femur from 55-year-old male donor was developed, and then a stability analysis was performed for the fixation provided by the retrograde nail at a distal fracture with different fracture gaps: 0.5 mm, 3 mm y 20 mm, respectively. Besides, for each gap, three nail lengths were studied with a general extent (320 mm, 280 mm and 240 mm), considering two transversal screws (M/L) at the distal part and different screw combinations above the fracture. The study was focused on the immediately post-operative stage, without any biological healing process. In view of the obtained results, it has been demonstrated new possibilities of blocking configuration in addition to the usual ones, which allows establishing recommendations for nail design and clinical practice, avoiding excessive stress concentrations both in screws, with the problem of rupture and loss of blocking, and in the contact of nail tip with cortical bone, with the problem of a new stress fracture.
Collapse
Affiliation(s)
- J Albareda-Albareda
- Department of Surgery, University of Zaragoza. Zaragoza, Spain; Aragón Health Research Institute. Zaragoza, Spain; Department of Orthopaedic Surgery and Traumatology, Lozano Blesa University Hospital, Spain
| | | | - J Rosell-Pradas
- Department of Mechanical Engineering, University of Zaragoza. Zaragoza, Spain
| | - S Puértolas-Broto
- Department of Mechanical Engineering, University of Zaragoza. Zaragoza, Spain; Aragón Institute for Engineering Research. Zaragoza, Spain
| | - E Ibarz-Montaner
- Department of Mechanical Engineering, University of Zaragoza. Zaragoza, Spain; Aragón Institute for Engineering Research. Zaragoza, Spain
| | - B Redondo-Trasobares
- Aragón Health Research Institute. Zaragoza, Spain; Department of Orthopaedic Surgery and Traumatology, Lozano Blesa University Hospital, Spain.
| | - J Gómez-Vallejo
- Department of Surgery, University of Zaragoza. Zaragoza, Spain; Aragón Health Research Institute. Zaragoza, Spain; Department of Orthopaedic Surgery and Traumatology, Lozano Blesa University Hospital, Spain
| | - N Blanco-Rubio
- Department of Surgery, University of Zaragoza. Zaragoza, Spain; Aragón Health Research Institute. Zaragoza, Spain; Department of Orthopaedic Surgery and Traumatology, Lozano Blesa University Hospital, Spain
| | - M Sánchez-Gimeno
- Department of Surgery, University of Zaragoza. Zaragoza, Spain; Aragón Health Research Institute. Zaragoza, Spain; Department of Orthopaedic Surgery and Traumatology, Lozano Blesa University Hospital, Spain
| | - A Herrera-Rodríguez
- Department of Surgery, University of Zaragoza. Zaragoza, Spain; Aragón Health Research Institute. Zaragoza, Spain; Aragón Institute for Engineering Research. Zaragoza, Spain
| | - L Gracia-Villa
- Department of Mechanical Engineering, University of Zaragoza. Zaragoza, Spain; Aragón Institute for Engineering Research. Zaragoza, Spain
| |
Collapse
|
9
|
Lian X, Zhao K, Chen W, Zhang J, Li J, Meng H, Hou Z, Zhang Y. Application of a double reverse traction repositor in the retrograde intramedullary nailing of distal femur fractures. J Orthop Surg Res 2021; 16:168. [PMID: 33658059 PMCID: PMC7927219 DOI: 10.1186/s13018-021-02324-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 02/22/2021] [Indexed: 11/10/2022] Open
Abstract
Objective The purpose of this prospective study was to introduce the application of a double reverse traction repositor (DRTR) in the retrograde intramedullary nailing (RE-IMN) of AO/OTA 33A distal femur fractures. Patients and methods A total of 27 patients with AO/OTA type 33A distal femur fractures who were admitted from January 2015 to May 2017 to a level I trauma center of a tertiary university hospital were enrolled in this prospective study. A DRTR was used to facilitate RE-IMN for the reduction of distal femur fractures in all patients. The demographic and fracture characteristics, surgical data, postoperative complications, and prognostic indicators of 24 patients were recorded. Results The DRTR helped achieve and maintain the reduction of all distal femur fractures in the present study. All surgeries were conducted by closed reduction, and excellent alignment was observed in the postoperative X-ray images. In the present study, 18 males and 6 females were included, and the average age of all patients was 51.3 years (range, 24–68 years). The mean operation time, intraoperative blood loss, intraoperative fluoroscopy time, and length of postoperative hospital stay were 137 min (range from 80 to 210 min), 320 ml (range from 200 to 600 ml), 28 (from 24 to 33), and 9 days (from 5 to 14 days), respectively. Eleven patients were found to have postoperative deep venous thrombosis before discharge. No cases of wound infection were observed. No cases of nonunion or malunion were observed. The average follow-up duration was 21 months (18–30 months). The average HHS, LKFS, and VAS scores at the 1-year follow-up were 89.9 (86–97), 79.1 (75–87), and 2.1 (from 0 to 5). No complications associated with DRTR were found. Conclusions A DRTR can be successfully applied in the treatment of distal femur fractures with RE-IMN, and it can not only help achieve or maintain the reduction of distal femur fractures with closed methods but also promote fixation with RE-IMN.
Collapse
Affiliation(s)
- Xiaodong Lian
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China
| | - Kuo Zhao
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China
| | - Wei Chen
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China
| | - Junzhe Zhang
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China
| | - Junyong Li
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China
| | - Hongyu Meng
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China
| | - Zhiyong Hou
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China.,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China.,NHC Key Laboratory of Intelligent Orthopaedic Equipment, The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Yingze Zhang
- Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, PR China. .,Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, PR China. .,Orthopaedic Research Institution of Hebei Province, Shijiazhuang, Hebei, 050051, PR China. .,NHC Key Laboratory of Intelligent Orthopaedic Equipment, The Third Hospital of Hebei Medical University, Shijiazhuang, China. .,Chinese Academy of Engineering, Beijing, 10088, P.R. China.
| |
Collapse
|
10
|
Tazawa R, Minehara H, Matsuura T, Kawamura T, Sakai R, Yoshida K, Inoue G, Takaso M. Biomechanical evaluation of internal fixation for the treatment of comminuted subtrochanteric femur fractures. J Orthop Sci 2021; 26:261-265. [PMID: 32245694 DOI: 10.1016/j.jos.2020.03.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 01/22/2020] [Accepted: 03/03/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND Several biomechanical studies on subtrochanteric femur fractures have reported that use of an intramedullary nail is superior to extramedullary implant. However, the optimal choice of intramedullary nail for the treatment of comminuted subtrochanteric femur fracture remains unclear. Here, we evaluated the biomechanical properties of comminuted subtrochanteric femur fracture treated with four different internal fixations. METHODS A comminuted subtrochanteric femur fracture model was created with a 2-cm gap below the lessor trochanter in 20 synthetic femurs. The fractures were fixed with one of four implants - Antegrade Femoral Nail (AFN), Trochanteric Fixation Nail Advanced with a femoral neck blade (TFNA blade), TFNA with a femoral neck screw (TFNA screw), and the reversed distal femoral locking compression plate (DF-LCP) - all manufactured by DePuy Synthes. Axial compression tests and torsion tests were performed and the stiffness of each implant was compared. RESULTS For compression, the TFNA blade, TFNA screw, and AFN provided significantly higher stiffness than DF-LCP (p < 0.001, p < 0.001, p = 0.001, respectively), and the TFNA blade provided significantly higher stiffness than AFN (p = 0.049). For torsion, there were no significant differences among the groups in internal rotation, while the TFNA screw had significantly lower torsional stiffness than the AFN, TFNA blade and DF-LCP in external rotation (p = 0.036, p = 0.034, p = 0.037, respectively). CONCLUSIONS These findings could help to provide biomechanical evidence regarding choice of implant for the treatment of comminuted subtrochanteric femur fracture. The TFNA blade may be more suitable for the treatment of comminuted subtrochanteric femur fracture.
Collapse
Affiliation(s)
- Ryo Tazawa
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0374, Japan.
| | - Hiroaki Minehara
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0374, Japan
| | - Terumasa Matsuura
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0374, Japan
| | - Tadashi Kawamura
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0374, Japan
| | - Rina Sakai
- Department of Medical Engineering and Technology, Kitasato University, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Kazuhiro Yoshida
- Department of Medical Engineering and Technology, Kitasato University, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Gen Inoue
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0374, Japan
| | - Masashi Takaso
- Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa 252-0374, Japan
| |
Collapse
|
11
|
Lu J, Guo SC, Wang QY, Sheng JG, Tao SC. J-bone graft with double locking plate: a symphony of mechanics and biology for atrophic distal femoral non-union with bone defect. J Orthop Surg Res 2020; 15:144. [PMID: 32293488 PMCID: PMC7161247 DOI: 10.1186/s13018-020-01636-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 03/13/2020] [Indexed: 12/13/2022] Open
Abstract
Objective Atrophic distal femur non-union with bone defect (ADFNBD) has been a worldwide challenge to treat due to the associated biological and mechanical problems. The purpose of this study was to introduce a new solution involving the use of a J-shaped iliac crest bone graft (J-bone) combined with double-plate (DP) in the treatment of femoral non-union. Methods Clinically, 18 patients with ADFNBD were included in this retrospective study and were treated with a combination of J-bone graft and DP. The average follow-up time was 22.1 ± 5.5 months (range, 14 to 34 months). The imaging information and knee joint activity tests and scores were used to evaluate the time to weight-bearing, the time to non-union healing, and the knee joint mobility. A finite element analysis was used to evaluate the differences between the following: (1) the use of a lateral locking plate (LLP) only group (LLP-only), (2) a DP only group (DP-only), (3) a DP with a J-bone group (DP+J-bone), and (4) an LLP with a J-bone group (LLP+J-bone) in the treatment of ADFNBD. A finite element analysis ABAQUS 6.14 (Dassault systems, USA) was used to simulate the von Mises stress distribution and model displacement of the plate during standing and normal walking. Result All patients with non-union and bone defect in the distal femur achieved bone healing at an average of 22.1 ± 5.5 months (range, 14 to 34 months) postoperatively. The average healing time was 6.72 ± 2.80 months. The knee Lysholm score was significantly improved compared with that before surgery. Under both 750 N and 1800 N axial stress, the maximum stress with the DP+J-bone structure was less than that of the LLP+J-bone and DP-only structures, and the maximum stress of J-bone in the DP+J-bone was significantly less than that of the LLP+J-bone+on structure. The fracture displacement of the DP+J-bone structure was also smaller than that of the LLP+J-bone and DP-only structures. Conclusion J-bone combined with DP resulted in less maximum stress and less displacement than did a J-bone combined with an LLP or a DP-only graft for the treatment of ADFNBD. This procedure was associated with less surgical trauma, early rehabilitation exercise after surgery, a high bone healing rate, and a satisfactory rate of functional recovery. Therefore, a combination of J-bone and DP is an effective and important choice for the treatment of ADFNBD.
Collapse
Affiliation(s)
- Jian Lu
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.,The Third Affiliated Hospital of Soochow University, Changzhou, 213003, Jiangsu, China
| | - Shang-Chun Guo
- Institute of Microsurgery on Extremities, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China
| | - Qi-Yang Wang
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China
| | - Jia-Gen Sheng
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
| | - Shi-Cong Tao
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
| |
Collapse
|
12
|
Comparative analysis of the biomechanical behavior of anterograde/retrograde nailing in supracondylar femoral fractures. Injury 2020; 51 Suppl 1:S80-S88. [PMID: 32067772 DOI: 10.1016/j.injury.2020.02.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 02/08/2020] [Indexed: 02/02/2023]
Abstract
Supracondylar femoral fractures account for a noticeable percentage of the femoral shaft fractures, affecting two etiological groups: high energy trauma in young men, with good bone quality, and older women with osteoporotic femur. Surgical treatment of those kind of fractures remains controversial, with different surgical options such as plate and sliding barrel locking condylar plate, less invasive stabilization system (LISS) or intramedullary nailing, which has emerged as a new fixation choice in the treatment of that type of fractures. The present work performs a comparative study about the biomechanical behavior of anterograde and retrograde nailing in supracondylar femoral fractures type A, in order to determine the best choice of nailing and locking configuration. A three-dimensional finite element model of the femur was developed, modeling femoral supracondylar fracture and different nailing configurations, both for anterograde and retrograde nails. The study was focused on the immediately post-operative stage, verifying the appropriate stability of the osteosynthesis. The obtained results show a better biomechanical behavior for anterograde nails, providing a better stability from the point of view of global movements, lower stresses in screws, and less stress concentration in cortical bone. So, for the analyzed fractures and osteosyntheses types, anterograde nailing has demonstrated to be a better surgical option, being an excellent indication in supracondylar fractures of femur, with clear benefits compared to retrograde nailing, providing a better stabilization which enables for a more satisfactory fracture healing.
Collapse
|
13
|
Abstract
OBJECTIVES To investigate the biomechanical properties of a lateral locked plate alone or in combination with a supplemental medial plate or an intramedullary nail (IMN). METHODS Intra-articular distal femur fractures with metaphyseal comminution (OTA/AO 33-C) were simulated with a standardized model in 28 synthetic femora and divided into 4 groups. Group I was instrumented with a 4.5-mm lateral locked distal femoral plate alone, group II with a lateral locked plate plus a low-profile precontoured 3.5-mm medial distal tibial plate, group III with a lateral locked plate plus a medial 3.5-mm reconstruction plate, and group IV with a lateral locked plate plus a retrograde IMN. Specimens were then axially loaded and cycled to failure or runout. Outcomes of interest were baseline stiffness, survivability, and cycles to failure. RESULTS Groups III and IV have a significantly higher baseline stiffness (P < 0.001) when compared with groups I and II. Furthermore, groups III and IV had a higher max load to failure (P < 0.01) when compared with groups I and II. The survivability in groups III and IV was 71% and 100%, respectively, while no specimens in group I or II survived maximum loading. There was no significant difference between group III and IV regarding stiffness, survivability, and cycles to failure. CONCLUSION When considering fixation for intra-articular distal femur fractures with metaphyseal comminution (OTA/AO 33-C), we found that supplementation of a lateral locked plate with a medial plate or an IMN to be biomechanically superior to lateral locked plating alone regarding stiffness, survivability, and cycles to failure. A low-profile precontoured plate did not add significantly to the construct stiffness in this study.
Collapse
|
14
|
Abstract
Distal femur fractures occur in a periarticular fracture pattern and disproportionately afflict an aging population. Although the goals of treatment have not changed, the emergence of new surgical techniques and devices has recently been developed and refined to treat this challenging fracture pattern. Treatment options include open reduction and internal fixation with periarticular locking plates, intramedullary nails, or distal femur replacement. Despite rapid adoption, these modern solutions display a concerning complication rate, specifically from nonunion and malunion. The indications for each of these treatment strategies are not well defined and are the subject of current debate. As with the use of any orthopaedic implant, the knowledge of the strengths and weaknesses of each construct is paramount to successful treatment of these fractures. Recently, as the understanding of the biomechanics of distal femur fracture healing has improved, the literature has demonstrated clinical and theoretical improvements in the outcomes after distal femur fracture repair.
Collapse
|
15
|
Chen Y, Yu XC. Efficacy of a Modified Scoring System to Facilitate Surgical Decision-making for Diaphyseal Malignancies: When is Devitalized Tumor-bearing Autograft of Value? Orthop Surg 2019; 11:586-594. [PMID: 31402605 PMCID: PMC6712409 DOI: 10.1111/os.12502] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 06/03/2019] [Accepted: 06/15/2019] [Indexed: 02/01/2023] Open
Abstract
Objectives To evaluate the validity of a modified scoring system (MSS) for inferring the bony quality of tumor‐bearing diaphyses and predicting the risk of reconstructive failure after devitalized bone replantation (DBR). Methods In this retrospective cohort study, we reviewed the records of 30 patients surgically treated for diaphyseal malignancies between 1996 and 2015. There were 18 male and 12 female subjects; the average age was 34.0 ± 24.5 years (8–82 years). Tumor locations comprised the femur (21), the humerus (4), the tibia (3), the radius (1), and the fibula (1). Histological diagnoses included osteosarcoma (13), metastases (4), Ewing sarcoma (3), chondrosarcoma (3), malignant fibrohistiocytoma (2), periosteal osteosarcoma (1), Langerhans cell sarcoma (1), lymphoma (1), rhabdomyosarcoma (1), and malignant giant cell tumor (1). All primary tumors were rated as stage IIB. Twenty patients underwent DBR. Prosthetic procedures and segmental autografting/allografting were performed in 7 and 3 cases, respectively. MSS (comprising 5 elements: pain, tumor location, bone destruction, localized dimension, and longitudinal dimension) for each patient was calculated in accordance with their preoperative presentations. Outcome measurements included oncological results, outcomes of reconstructions, complications, and functional preservation, presented using the musculoskeletal tumor society (MSTS) scale. Results Follow up was available in 29 cases for an average duration of 61.0 ± 49.9 months (12–152 months). Infection occurred in 2 patients (6.9%), primary nonunion in 6 (27.3%), metastases in 9 (31.9%), recurrences in 4 (13.8%), and deaths in 7 (24.1%); 1 subject underwent amputation due to recurrence following endoprosthetic replacement (3.4%). In the DBR group, fractures occurred in 4 cases (21.1%) and nonunion in 5 (25%); internal fixation was related to nonunion (nails, 44.4% vs plates, 9.1%, P = 0.02). MSS was associated with fractures of devitalized autografts (11.0 ± 1.2 vs 8.3 ± 1.8, P = 0.01); the system was efficacious in predicting chances of fractures of these grafts (P = 0.02). MSS ≥ 10 (with false positive rate ≤ 6.7%) suggested increased fracture probability (≥22.7%) after DBR; therefore, 10 was considered a cutoff value. Conclusions Diaphyseal malignancies with MSS ≥10 may contraindicate DBR for increased chances of reconstructive failure. In this situation, alternative procedures are advisable. Further investigations are warranted to assess the efficacy of MSS in implying the validity of DBR for diaphyseal malignancies.
Collapse
Affiliation(s)
- Yu Chen
- Orthopaedic Department, 960 Hospital of People's Liberation Army, Jinan, China
| | - Xiu-Chun Yu
- Orthopaedic Department, First Hospital of China Medical University, Shenyang, China
| |
Collapse
|
16
|
Alzheimer Dementia in the Orthopaedic Patient. J Am Acad Orthop Surg 2019; 27:e311-e318. [PMID: 30320729 DOI: 10.5435/jaaos-d-17-00661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Alzheimer disease is a neurologic disorder characterized by the progressive cognitive decline. As the population continues to age, orthopaedic surgeons need to become familiar with surgical and nonsurgical treatment considerations in this complex population. Despite the advances in geriatric and dementia care, surgical and postoperative management of both elective and emergent surgery remain complex and controversial in this patient population. Appropriate perioperative and postoperative management can optimize outcomes, and the management can significantly affect the quality of life of patient and caregiver and limit disease burden. Any treatment decision should be guided first and foremost by the goals of care as agreed between the surgeon, other providers, and family. Surgical management must be demand matched to the patient accounting for the severity of disease, life expectancy, and the social support system. The authors conducted a literature review of Alzheimer dementia care in orthopaedic patients via a Pubmed search of relevant articles published since 1980.
Collapse
|
17
|
Long Segment Blocking Screws Increase the Stability of Retrograde Nail Fixation in Geriatric Supracondylar Femur Fractures: Eliminating the "Bell-Clapper Effect". J Orthop Trauma 2018; 32:559-564. [PMID: 30086037 DOI: 10.1097/bot.0000000000001284] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES To determine the change in stiffness and horizontal translations of a geriatric supracondylar femur fracture model with the addition of distal segment blocking screws versus proximal (long) segment blocking screws to the standard retrograde intramedullary nail construct. METHODS Unstable supracondylar femur fractures (OTA/AO 33-A3) were created; all specimens were instrumented with a retrograde intramedullary nail. Specimens were divided into 2 groups (6 matched pairs per group). Group 1 compared the standard construct (1 proximal screw and 3 distal screws) to a distally augmented construct, with blocking screws placed in the distal metaphyseal segment. Group 2 compared the distally augmented construct to one in which blocking screws were placed just proximal to the fracture (long segment blocking screws). Specimens were then axially loaded and cycled to failure or run-out. RESULTS There was no significant difference in baseline stiffness, survival through cyclic loading, stiffness after cyclic loading, or cycles to failure between femurs treated with distal blocking screws and femurs treated without blocking screws (group 1). Femurs with blocking screws in the long proximal segment had significantly greater baseline stiffness, stiffness after cyclic loading, and less horizontal translation at the fracture site (group 2). There was no difference in survival through cyclic loading or cycles to failure. CONCLUSION Long segment blocking screws are biomechanically superior to blocking screws in the distal segment or no blocking screws initially and after cyclic loading in an unstable geriatric supracondylar femur fracture model treated with intramedullary nail. CLINICAL RELEVANCE Surgeons may use blocking screws to aid in fracture alignment during retrograde nail fixation. In addition, the placement of long segment blocking screws can help resist failure of fixation in geriatric patients by eliminating the "Bell-clapper effect."
Collapse
|
18
|
Chen J, Lu H. [Current status and progress of clinical research on distal femoral fractures]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2018; 32:242-247. [PMID: 29806419 DOI: 10.7507/1002-1892.201704132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To investigate current status and latest progress of clinical research on distal femoral fractures. Methods The related literature was extensively reviewed to summarize the trend of the researches and their clinical application in the treatment of distal femoral fractures. Results Distal femoral fractures are likely to occur in young people who suffer from high-energy damage and the elderly with osteoporosis, which is always comminuted and unstable fractures, and often involved in the articular surface and combined with serious soft tissue injury. Therefore, the treatment faces many challenges. External fixation is now used as a temporary means of controlling injury. The vast majority of patients are feasible to internal fixation, including plates system and intramedullary nail system. Different internal fixator also has its own characteristics, such as double plates can strengthen the medial support of the femur, less invasive stabilization system protects the blood supply of fractures, distal cortial locking plate is theoretically more fit for the requirements of bone healing, retrograde intramedullary nail can resist varus and valgus. Conclusion The treatment of distal femoral fractures should be based on the type of fracture and the characteristics of internal fixators.
Collapse
Affiliation(s)
- Jishizhan Chen
- Department of Orthopaedics, Xin Hua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, 200092, P.R.China
| | - Hua Lu
- Department of Orthopaedics, Xin Hua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, 200092,
| |
Collapse
|
19
|
Steinberg EL, Elis J, Steinberg Y, Salai M, Ben-Tov T. A double-plating approach to distal femur fracture: A clinical study. Injury 2017; 48:2260-2265. [PMID: 28768571 DOI: 10.1016/j.injury.2017.07.025] [Citation(s) in RCA: 73] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2017] [Revised: 07/16/2017] [Accepted: 07/24/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND Locked plating is one of the latest innovative options for treating supracondylar femur fractures with relatively low failure rates. Single lateral plating was often found to have a relative higher failure rate. No clinical studies of double-plating distal femur fixation have thus far been reported. The aim of this study is to present our clinical experience with this surgical approach. PATIENTS AND METHODS Thirty-two patients (26 females and 6 males, mean age 76 years, range 44-101) were included in the study. Eight of them patients had a periprosthetic stable implant fracture and two patients were treated for a nonunion. RESULTS All fractures, excluding one that needed bone grafting and one refracture, healed within 12 weeks. One patient needed bone grafting for delayed union and one patient needed fixation exchange due to femur re-fracture at the site of the most proximal screw. Two patients developed superficial wound infection and one patient required medial plate removal after union due to deep infection. CONCLUSIONS Based on these promising results, we propose that the double-plating technique should be considered in the surgeon's armamentarium for the treatment of supracondylar femur fractures, particularly in patients with poor bone quality, comminuted fractures and very low periprosthetic fractures.
Collapse
Affiliation(s)
- Ely L Steinberg
- Orthopaedic Division, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel.
| | - Jacov Elis
- Orthopaedic Division, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel
| | - Yohai Steinberg
- Orthopaedic Division, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel
| | - Moshe Salai
- Orthopaedic Division, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel
| | - Tomer Ben-Tov
- Orthopaedic Division, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel
| |
Collapse
|
20
|
Shin YS, Kim HJ, Lee DH. Similar outcomes of locking compression plating and retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 2017; 25:2921-2928. [PMID: 26897137 DOI: 10.1007/s00167-016-4050-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Accepted: 02/05/2016] [Indexed: 12/19/2022]
Abstract
PURPOSE This meta-analysis was designed to compare clinical outcomes, including knee scale score and nonunion rate, of patients with periprosthetic supracondylar fractures of the distal femur after total knee arthroplasty (TKA) who were treated using locking compression plates and retrograde intramedullary nails. METHODS Studies were included in this meta-analysis if they compared clinical outcomes, including operation time, Knee Society Score (KSS), time to union, nonunion rate, and revision rate due to nonunion, in patients who underwent locking compression plate or retrograde intramedullary nail for periprosthetic distal femur fractures following TKA. RESULTS Eight studies were included in this meta-analysis. Mean operation time was 11 min shorter (95 % CI -9.56 to 31.33 min; n.s.) and KSS one point higher (95 % CI -8.88 to 11.10; n.s.) with retrograde intramedullary nail than with locking compression plate, but these differences were not statistically significant. The two groups were also similar in mean time to union (0.46 weeks 95 % CI -1.17 to 2.08 weeks; n.s.), the proportion of subjects with nonunion (OR 0.83, 95 % CI 0.26-2.60; n.s.) and the proportion that underwent revision surgery (OR 0.88, 95 % CI 0.32-2.40; n.s.). CONCLUSIONS Clinical outcomes, including nonunion and revision rates, were similar in patients who underwent locking compression plate and retrograde intramedullary nail fixation for periprosthetic supracondylar femoral fracture following TKA. Orthopaedic surgeons must train to master both the retrograde intramedullary nail and locking compression plate techniques because both approaches can be considered for periprosthetic distal femur fracture after TKA as they have similar clinicoradiologic outcomes. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Young-Soo Shin
- Department of Orthopedic Surgery, Seoul Veterans Hospital, Seoul, Korea
| | - Hyun-Jung Kim
- Department of Preventive Medicine, Korea University College of Medicine, Seoul, Korea
| | - Dae-Hee Lee
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 135-710, Korea.
| |
Collapse
|
21
|
Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis. J Orthop Trauma 2017; 31:e241-e246. [PMID: 28394844 DOI: 10.1097/bot.0000000000000860] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. METHODS An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. RESULTS Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. CONCLUSIONS Using the same plate design, the study showed that implant material, screw type, and position of the plate affect the construct stiffness and fatigue life of the fixation construct. With this knowledge, the surgeon can decide the optimal construct based on a given fracture pattern, bone strength, and reduction quality.
Collapse
|
22
|
Atrey A, Hussain N, Gosling O, Giannoudis P, Shepherd A, Young S, Waite J. A 3 year minimum follow up of Endoprosthetic replacement for distal femoral fractures - An alternative treatment option. J Orthop 2017; 14:216-222. [PMID: 28115800 DOI: 10.1016/j.jor.2016.12.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Accepted: 12/25/2016] [Indexed: 01/16/2023] Open
Abstract
INTRODUCTION Although the use of an endoprosthesis for distal femoral fractures remains a valid treatment option the widespread use is in its infancy. METHODOLOGY In this retrospective case series, we review cases of distal femoral fracture treated with endoprosthetic replacement (EPR). The outcomes we assessed were the time to start mobilising, the time to discharge, morbidity and mortality as well as an Oxford knee score to assess pain and function and also the early survivorship. 6 of the 11 from the cohort had existing Total Knee Replacements (TKRs) in situ. RESULTS There were 11 knees in our cohort with a mean age of 81.5 years (range 52-102 years). The median time to follow up was 3.5 years (range 1.6 to 5.5 years). The median times to theatre was 3 days and to discharge was 16 days. Oxford functional and pain scores were 32/48. DISCUSSION In the appropriate patient and fracture pattern, Endoprosthetic knee replacement is an excellent option in the treatment of distal femoral fractures whether associated with an existing TKR or not. The implant is more costly than traditional open reduction and internal fixation, but the earlier return to full mobility post-operatively may save on hospital/care home stay and free up hospital space and minimise complications.
Collapse
Affiliation(s)
- A Atrey
- St Michael's Hospital, Toronto, Canada
| | | | | | | | - A Shepherd
- Warwick Hospital Orthopaedic Research Unit, UK
| | - S Young
- Warwick Hospital Orthopaedic Research Unit, UK
| | - J Waite
- Warwick Hospital Orthopaedic Research Unit, UK
| |
Collapse
|
23
|
Konan S, Sandiford N, Unno F, Masri BS, Garbuz DS, Duncan CP. Periprosthetic fractures associated with total knee arthroplasty. Bone Joint J 2016; 98-B:1489-1496. [PMID: 27803224 DOI: 10.1302/0301-620x.98b11.bjj-2016-0029.r1] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Accepted: 06/30/2016] [Indexed: 11/05/2022]
Abstract
Fractures around total knee arthroplasties pose a significant surgical challenge. Most can be managed with osteosynthesis and salvage of the replacement. The techniques of fixation of these fractures and revision surgery have evolved and so has the assessment of outcome. This specialty update summarises the current evidence for the classification, methods of fixation, revision surgery and outcomes of the management of periprosthetic fractures associated with total knee arthroplasty. Cite this article: Bone Joint J 2016;98-B:1489–96.
Collapse
Affiliation(s)
- S. Konan
- University of British Columbia, Vancouver
General Hospital, JP North 3rd floor, Room 3114, 910
West 10th Avenue, Vancouver, BC
V5Z 4E3, Canada
| | - N. Sandiford
- University of British Columbia, Vancouver
General Hospital, JP North 3rd floor, Room 3114, 910
West 10th Avenue, Vancouver, BC
V5Z 4E3, Canada
| | - F. Unno
- University of British Columbia, Vancouver
General Hospital, JP North 3rd floor, Room 3114, 910
West 10th Avenue, Vancouver, BC
V5Z 4E3, Canada
| | - B. S. Masri
- University of British Columbia, Vancouver
General Hospital, JP North 3rd floor, Room 3114, 910
West 10th Avenue, Vancouver, BC
V5Z 4E3, Canada
| | - D. S. Garbuz
- University of British Columbia, Vancouver
General Hospital, JP North 3rd floor, Room 3114, 910
West 10th Avenue, Vancouver, BC
V5Z 4E3, Canada
| | - C. P. Duncan
- University of British Columbia, Vancouver
General Hospital, JP North 3rd floor, Room 3114, 910
West 10th Avenue, Vancouver, BC
V5Z 4E3, Canada
| |
Collapse
|
24
|
Pean CA, Konda SR, Fields AC, Christiano A, Egol KA. Perioperative adverse events in distal femur fractures treated with intramedullary nail versus plate and screw fixation. J Orthop 2015; 12:S195-9. [PMID: 27047223 PMCID: PMC4796573 DOI: 10.1016/j.jor.2015.10.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Accepted: 10/04/2015] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND To compare 30-day outcomes in patients treated for a distal femur (DF) fracture with plate fixation (PF) or intramedullary nail (IMN). METHODS Differences in rates of any adverse events (AAE), serious adverse events (SAE), infectious complications, and mortality were explored between groups in the ACS-NSQIP database. RESULTS There were 511 PF and 44 IMN patients. The PF group and IMN groups had similar rates of AAEs (p = 0.35), SAEs (p = 0.46), infectious complications (p = 1.00), and mortality (p = 0.39). CONCLUSIONS DF fractures treated with IMN have equivalent short-term outcomes compared to those treated with PF.
Collapse
Affiliation(s)
- Christian A. Pean
- NYU Hospital for Joint Diseases, Department of Orthopaedic Surgery, New York, NY 10003, USA
| | - Sanjit R. Konda
- NYU Hospital for Joint Diseases, Department of Orthopaedic Surgery, New York, NY 10003, USA
- Jamaica Hospital Medical Center, Queens, NY, USA
| | - Adam C. Fields
- NYU Hospital for Joint Diseases, Department of Orthopaedic Surgery, New York, NY 10003, USA
| | - Anthony Christiano
- NYU Hospital for Joint Diseases, Department of Orthopaedic Surgery, New York, NY 10003, USA
| | - Kenneth A. Egol
- NYU Hospital for Joint Diseases, Department of Orthopaedic Surgery, New York, NY 10003, USA
| |
Collapse
|
25
|
Lampropoulou-Adamidou K, Tosounidis TH, Kanakaris NK, Ekkernkamp A, Wich M, Giannoudis PV. The outcome of Polyax Locked Plating System for fixation distal femoral non-implant related and periprosthetic fractures. Injury 2015; 46 Suppl 5:S18-24. [PMID: 26343298 DOI: 10.1016/j.injury.2015.08.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The objective of this study was to report on the safety, efficacy and clinical outcomes of the Polyax Locked Plating System (Biomet, Warsaw, IN, USA) in the management of acute (non-implant related and periprosthetic) distal femoral fractures. We retrospectively reviewed 71 patients with 73 distal femoral fractures. Thirty-three of the included fractures occurred around previously placed implants. The average patients' age was 67 years (range 18-98). There were 7 early postoperative complications (9.5%) including one deep surgical site infection, 2 pulmonary embolisms and 4 urinary or respiratory infections. At final follow-up (mean 12, range 9-55 months) all fractures progressed to clinical and radiological union. However, major revision surgery for healing problems was required in 5 cases (6.8%) and minor in 3 cases (4.1%). The average time to healing was 6 (range 3-23) months. Angulation less than 5 degrees in any plane was observed in 66 cases (89.7%), within 5-10 degrees in 5 cases (7.3%) and within 10-15 degrees in 2 cases (2.9%). The mean pre-injury and final follow-up values of Glasgow Outcome Scale were 1.5(1-3) and 1.7(1-3) respectively. Overall 61 patients (83.53%) retained their pre-injury activity status. The Polyax Locked Plating System offers a safe and efficient fixation in distal femoral fractures.
Collapse
Affiliation(s)
- Kalliopi Lampropoulou-Adamidou
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK
| | - Theodoros H Tosounidis
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK; NIHR Leeds Biomedical Research Unit, Chapel Allerton Hospital, West Yorkshire, LS7 4SA Leeds, UK
| | - Nikolaos K Kanakaris
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK
| | - Axel Ekkernkamp
- Department of Trauma and Orthopedic Surgery, Unfallkrankenhaus Berlin, Warener Str. 7, 12683 Berlin, Germany
| | - Michael Wich
- Department of Trauma and Orthopedic Surgery, Unfallkrankenhaus Berlin, Warener Str. 7, 12683 Berlin, Germany; Klinikum Dahme-Spreewald, Koepenicker Str. 29, 15711 Koenigs Wusterhausen, Germany
| | - Peter V Giannoudis
- Academic Department of Trauma & Orthopaedic Surgery, University of Leeds, Clarendon Wing, Floor A, Great George Street, Leeds General Infirmary, LS1 3EX Leeds, UK; NIHR Leeds Biomedical Research Unit, Chapel Allerton Hospital, West Yorkshire, LS7 4SA Leeds, UK.
| |
Collapse
|
26
|
Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation. INTERNATIONAL ORTHOPAEDICS 2015; 39:1737-42. [DOI: 10.1007/s00264-015-2764-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Accepted: 03/17/2015] [Indexed: 12/22/2022]
|