1
|
Xu T, Zeng Y, Yang X, Liu G, Lv T, Yang H, Jiang F, Chen Y. Application of 68Ga-citrate PET/CT for differentiating periprosthetic joint infection from aseptic loosening after joint replacement surgery. Bone Joint Res 2022; 11:398-408. [PMID: 35731211 PMCID: PMC9233412 DOI: 10.1302/2046-3758.116.bjr-2021-0464.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIMS We aimed to evaluate the utility of 68Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with 99mTc-methylene bisphosphonates (99mTc-MDP) bone scan. METHODS We studied 39 patients with suspected PJI or AL. These patients underwent 68Ga-citrate PET/CT, 99mTc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations. RESULTS Overall, 23 and 16 patients were diagnosed with PJI and AL, respectively. The sensitivity and specificity of three-phase bone scan and SPECT/CT were 100% and 62.5%, 82.6%, and 100%, respectively. Attenuation correction (AC) at 60 minutes and non-AC at 60 minutes of PET/CT had the same highest sensitivity and specificity (91.3% and 100%), and AC at 60 minutes combined with SPECT/CT could improve the diagnostic efficiency (sensitivity = 95.7%). Diagnostic efficacy of the SUVmax was low (area under the curve (AUC) of ten minutes and 60 minutes was 0.814 and 0.806, respectively), and SUVmax of the lesion/SUVmean of the normal bone at 60 minutes was the best semi-quantitative parameter (AUC = 0.969). CONCLUSION 68Ga-citrate showed the potential to differentiate PJI from AL, and visual analysis based on uptake pattern of tracer was reliable. The visual analysis method of AC at 60 minutes, combined with 99mTc-MDP SPECT/CT, could improve the sensitivity from 91.3% to 95.7%. In addition, a major limitation of our study was that it had a limited sample size, and more detailed studies with a larger sample size are warranted. Cite this article: Bone Joint Res 2022;11(6):398-408.
Collapse
Affiliation(s)
- Tingting Xu
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China.,Institute of Nuclear Medicine, Southwest Medical University, Luzhou, Sichuan, China
| | - Yalan Zeng
- Department of Orthopedics, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Xiao Yang
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China.,Institute of Nuclear Medicine, Southwest Medical University, Luzhou, Sichuan, China
| | - Guangfu Liu
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China.,Institute of Nuclear Medicine, Southwest Medical University, Luzhou, Sichuan, China
| | - Taiyong Lv
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China.,Institute of Nuclear Medicine, Southwest Medical University, Luzhou, Sichuan, China
| | - Hongbin Yang
- Department of Orthopedics, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Fei Jiang
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China.,Institute of Nuclear Medicine, Southwest Medical University, Luzhou, Sichuan, China
| | - Yue Chen
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China.,Institute of Nuclear Medicine, Southwest Medical University, Luzhou, Sichuan, China
| |
Collapse
|
2
|
Logoluso N, Pellegrini A, Suardi V, Morelli I, Battaglia AG, D'Anchise R, De Vecchi E, Zagra L. Can the Leukocyte Esterase Strip Test Predict Persistence of Periprosthetic Joint Infection at Second-Stage Reimplantation? J Arthroplasty 2022; 37:565-573. [PMID: 34822929 DOI: 10.1016/j.arth.2021.11.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 11/05/2021] [Accepted: 11/15/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND We evaluated the reliability of intraoperative assessment of leukocyte esterase (LE) in synovial fluid samples from patients undergoing reimplantation following implant removal and spacer insertion for periprosthetic joint infection (PJI). Our hypothesis was that a positive intraoperative LE test would be a better predictor of persistent infection than either serum C-reactive protein (CRP) or erythrocyte sedimentation rate (ESR) or the combination of serum CRP and ESR. METHODS The records of 76 patients who received a 2-stage exchange for PJI were retrospectively reviewed. Synovial fluid was collected for LE measurement during surgery before arthrotomy in 79 procedures. Receiver operating characteristic curves were generated. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and area under the curve (AUC) of LE, CRP, ESR, and CRP + ESR were calculated. RESULTS Sensitivity, specificity, positive predictive value, and negative predictive value of the LE assay were 82%, 99%, 90%, and 97%, respectively. Receiver operating characteristic analysis revealed an LE threshold of 1.5 between the first (negative) and the second (positive) level of the ordinal variable, so that a grade starting from 1+ was accurate for a diagnosis of persistent infection (AUC 0.9044). The best thresholds for the CRP and the ESR assay were 8.25 mg/L (82% sensitivity, 84% specificity, AUC 0.8416) and 45 mm/h (55% sensitivity, 87% specificity, AUC 0.7493), respectively. CONCLUSION The LE strip test proved a reliable tool to diagnose persistence of infection and outperformed the serum CRP and ESR assays. The strip test provides a valuable intraoperative diagnostic during second-stage revision for PJI.
Collapse
Affiliation(s)
- Nicola Logoluso
- Department of Reconstructive Surgery of Osteo-articular Infections, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Antonio Pellegrini
- Department of Reconstructive Surgery of Osteo-articular Infections, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Virginia Suardi
- Department of Reconstructive Surgery of Osteo-articular Infections, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Ilaria Morelli
- ASST Ovest Milanese, UOC Ortopedia e Traumatologia, Ospedale di Legnano, Milan, Italy
| | | | | | - Elena De Vecchi
- IRCCS Istituto Ortopedico Galeazzi, Laboratory of Clinical Chemistry and Microbiology, Milan, Italy
| | - Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| |
Collapse
|