1
|
Van Ravestyn A, Frantz T, Vandemeulebroucke J, Jansen B, Duerinck J, Scheerlinck T. Determination of rotation center and diameter of femoral heads using off-the-shelf augmented reality hardware for navigation. Sci Rep 2024; 14:15458. [PMID: 38965266 PMCID: PMC11224340 DOI: 10.1038/s41598-024-64957-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Accepted: 06/14/2024] [Indexed: 07/06/2024] Open
Abstract
In total hip arthroplasty (THA), determining the center of rotation (COR) and diameter of the hip joint (acetabulum and femoral head) is essential to restore patient biomechanics. This study investigates on-the-fly determination of hip COR and size, using off-the-shelf augmented reality (AR) hardware. An AR head-mounted device (HMD) was configured with inside-out infrared tracking enabling the determination of surface coordinates using a handheld stylus. Two investigators examined 10 prosthetic femoral heads and cups, and 10 human femurs. The HMD calculated the diameter and COR through sphere fitting. Results were compared to data obtained from either verified prosthetic geometry or post-hoc CT analysis. Repeated single-observer measurements showed a mean diameter error of 0.63 mm ± 0.48 mm for the prosthetic heads and 0.54 mm ± 0.39 mm for the cups. Inter-observer comparison yielded mean diameter errors of 0.28 mm ± 0.71 mm and 1.82 mm ± 1.42 mm for the heads and cups, respectively. Cadaver testing found a mean COR error of 3.09 mm ± 1.18 mm and a diameter error of 1.10 mm ± 0.90 mm. Intra- and inter-observer reliability averaged below 2 mm. AR-based surface mapping using HMD proved accurate and reliable in determining the diameter of THA components with promise in identifying COR and diameter of osteoarthritic femoral heads.
Collapse
Affiliation(s)
- Antoine Van Ravestyn
- Department of Orthopedic Surgery and Traumatology, Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium.
- Vrije Universiteit Brussel (VUB), Research Group BEFY-ORTHO, Laarbeeklaan 103, 1090, Brussels, Belgium.
| | - Taylor Frantz
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050, Brussels, Belgium
- IMEC, Kapeldreef 75, 3001, Leuven, Belgium
| | - Jef Vandemeulebroucke
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050, Brussels, Belgium
- IMEC, Kapeldreef 75, 3001, Leuven, Belgium
- Department of Radiology, Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Bart Jansen
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050, Brussels, Belgium
- IMEC, Kapeldreef 75, 3001, Leuven, Belgium
| | - Johnny Duerinck
- Department of Neurosurgery, Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Thierry Scheerlinck
- Department of Orthopedic Surgery and Traumatology, Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium
- Vrije Universiteit Brussel (VUB), Research Group BEFY-ORTHO, Laarbeeklaan 103, 1090, Brussels, Belgium
| |
Collapse
|
2
|
Zajc J, Fokter SK. Bimodular femoral stems in primary total hip arthroplasty. Expert Rev Med Devices 2023; 20:1051-1064. [PMID: 37753590 DOI: 10.1080/17434440.2023.2264177] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 09/25/2023] [Indexed: 09/28/2023]
Abstract
INTRODUCTION This review critically examines the efficacy of dual-modular stems in primary total hip arthroplasty. Given the variability and non-comparability of certain femoral stem designs and stem-neck couplings, with some even being withdrawn from the market, this review offers an in-depth analysis of predominant implant performances. AREAS COVERED The paper explores a brief historical summary related to dual-modular stems, including the complications associated with their use, diagnostic tools for evaluation, analysis of both recalled and currently available models, as well as alternative therapeutic options. This information is pertinent for both clinical and research domains. EXPERT OPINION While dual-modular systems were initially touted to offer several advantages, the evidence substantiating these benefits has been ambiguous. Further, these systems introduce the risk of alternative complications. In specific cases involving patients with developmental hip dysplasia and certain proximal femoral deformities requiring complex reconstructions, dual-modular systems might be relevant. Nonetheless, the use of long interchangeable necks in patients with a body mass index above 30 kg/m2 is discouraged, and pairing a long varus-oriented neck with an extra-long femoral head should be avoided in all patients.
Collapse
Affiliation(s)
- Jan Zajc
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| | - Samo K Fokter
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| |
Collapse
|
3
|
Imaging in Hip Arthroplasty Management-Part 1: Templating: Past, Present and Future. J Clin Med 2022; 11:jcm11185465. [PMID: 36143112 PMCID: PMC9503653 DOI: 10.3390/jcm11185465] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 09/11/2022] [Accepted: 09/15/2022] [Indexed: 11/17/2022] Open
Abstract
Hip arthroplasty is a frequently used procedure with high success rates. Its main indications are primary or secondary advanced osteoarthritis, due to acute fracture, osteonecrosis of the femoral head, and hip dysplasia. The goals of HA are to reduce pain and restore normal hip biomechanics, allowing a return to the patient’s normal activities. To reach those goals, the size of implants must suit, and their positioning must meet, quality criteria, which can be determined by preoperative imaging. Moreover, mechanical complications can be influenced by implant size and position, and could be avoided by precise preoperative templating. Templating used to rely on standard radiographs, but recently the use of EOS® imaging and CT has been growing, given the 3D approach provided by these methods. However, there is no consensus on the optimal imaging work-up, which may have an impact on the outcomes of the procedure. This article reviews the current principles of templating, the various imaging techniques used for it, as well as their advantages and drawbacks, and their expected results.
Collapse
|