1
|
Wang G, Rhodes TL, Peebles WA. Analysis method for calculating radial correlation length of electron temperature turbulence from correlation electron cyclotron emission radiometer. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:113511. [PMID: 36461495 DOI: 10.1063/5.0101680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 09/01/2022] [Indexed: 06/17/2023]
Abstract
The radial correlation length (Lr) is one of the essential quantities to measure in order to more fully characterize and understand turbulence and anomalous transport in magnetic fusion plasmas. The analysis method for calculating Lr of electron temperature (Te) turbulence from correlation electron cyclotron emission (correlation ECE or CECE) radiometer measurements has not been fully developed partly due to the fact that the turbulent electron temperature fluctuations are generally imbedded in much larger amplitude thermal noise, which leads to a greatly reduced cross correlation coefficient (ϱ) between two spatially separated ECE signals. This work finds that this ϱ reduction factor due to thermal noise is a function of the local relative temperature fluctuation power and CECE system bandwidths of intermediate and video frequencies, independent of radial separations. This indicates that under the approximation of constant relative temperature fluctuation power for a small radial range of local CECE measurements, the original shape of ϱ as a function of radial separation without thermal noise is preserved in the CECE data with thermal noise present. For Te turbulence with a Gaussian radial wavenumber spectrum, a fit function using the product of Gaussian and sinusoidal functions is derived for calculating Lr. This analysis method has been numerically tested using simulated ECE radiometer data over a range of parameters. Using this method, the experimental temperature turbulence correlation length Lr in a DIII-D L-mode plasma is found to be ∼10 times the local ion gyroradius.
Collapse
Affiliation(s)
- G Wang
- Department of Physics and Astronomy, University of California, Los Angeles, California 90095, USA
| | - T L Rhodes
- Department of Physics and Astronomy, University of California, Los Angeles, California 90095, USA
| | - W A Peebles
- Department of Physics and Astronomy, University of California, Los Angeles, California 90095, USA
| |
Collapse
|
2
|
Wang G, Rhodes TL, Peebles WA. New, improved analysis of correlation ECE data to accurately determine turbulent electron temperature spectra and magnitudes (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:043523. [PMID: 34243388 DOI: 10.1063/5.0041858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Accepted: 03/23/2021] [Indexed: 06/13/2023]
Abstract
Turbulent electron temperature fluctuation measurement using a correlation electron cyclotron emission (CECE) radiometer has become an important diagnostic for studying energy transport in fusion plasmas, and its use is widespread in tokamaks (DIII-D, ASDEX Upgrade, Alcator C-Mod, Tore Supra, EAST, TCV, HL-2A, etc.). The CECE diagnostic typically performs correlation analysis between two closely spaced (within the turbulent correlation length) ECE channels that are dominated by uncorrelated thermal noise emission. This allows electron temperature fluctuations embedded in the thermal noise to be revealed and fluctuation level and spectra determined. We have demonstrated a new, improved CECE coherency-based analysis for calculating the temperature fluctuation frequency spectrum and level, which has been verified both numerically through the simulation of synthetic ECE radiometer data and through analysis of experimental data from the CECE system on DIII-D. The new formulation places coherency-based analysis on a firm foundational footing and corrects some currently published methodologies. This new method accurately accounts for bias error in the coherence function and correctly calculates noise levels for a fixed data record length. It provides excellent accuracy in determining temperature fluctuation level (e.g., <10% error) even for a small realization number in the ensemble average. The method also has a smaller uncertainty (i.e., error bar) in the power spectrum when compared to the more standard cross-power method when evaluated at low coherency. Direct calculation of system noise level using correlation between randomized intermediate frequency signals is recommended.
Collapse
Affiliation(s)
- G Wang
- Department of Physics and Astronomy, University of California, Los Angeles, California 90095, USA
| | - T L Rhodes
- Department of Physics and Astronomy, University of California, Los Angeles, California 90095, USA
| | - W A Peebles
- Department of Physics and Astronomy, University of California, Los Angeles, California 90095, USA
| |
Collapse
|
3
|
Hicks NK, Suttrop W, Behler K, García-Muñoz M, Giannone L, Maraschek M, Raupp G, Reich M, Sips ACC, Stober J, Treutterer W, Volpe F, Cirant S, D’Antona G. Fast Sampling Upgrade and Real-Time NTM Control Application of the ECE Radiometer on ASDEX Upgrade. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.13182/fst57-1-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- N. K. Hicks
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - W. Suttrop
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - K. Behler
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - M. García-Muñoz
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - L. Giannone
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - M. Maraschek
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - G. Raupp
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - M. Reich
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - A. C. C. Sips
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - J. Stober
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - W. Treutterer
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - F. Volpe
- Max Planck Institut für Plasmaphysik EURATOM Association, 85748 Garching, Germany
| | - S. Cirant
- Istituto di Fisica del Plasma Associazione EURATOM-ENEA-CNR, 20125 Milano, Italy
| | - G. D’Antona
- Politecnico di Milano, Dip. di Elettrotecnica P.za L. da Vinci 32, 20133 Milano, Italy
| | | |
Collapse
|
4
|
Yang ZJ, Pan XM, Ma XD, Ruan BW, Zhou RB, Zhang C. Electron cyclotron emission radiometer upgrade on the J-TEXT tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E112. [PMID: 27910414 DOI: 10.1063/1.4960167] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
To meet experimental requirements, the J-TEXT electron cyclotron emission (ECE) diagnostic is being upgraded. The front end antenna and transmission line have been modified and a new 8-channel W-band detecting unit has been developed. The improved ECE system will extend the frequency range from 94.5-124.5 GHz to 80.5-124.5 GHz. This will enable the system to cover the most plasma in the radius direction for BT = 1.8-2.2 T, and it even can cover almost the whole plasma range ρ = - 0.8-0.9 (minus means the high field side) at BT = 1.8 T. A new auxiliary channel bank with 8 narrow band, tunable yttrium iron garnet filters is planned to add to the ECE system. Due to observations along a major radius, perpendicular to BT, and relatively low electron temperature, Doppler and relativistic broadening are minimal and thus high spatial resolution measurements can be made at variable locations with these tunable channels.
Collapse
Affiliation(s)
- Z J Yang
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - X M Pan
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - X D Ma
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - B W Ruan
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - R B Zhou
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - C Zhang
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| |
Collapse
|
5
|
Schmuck S, Fessey J, Boom JE, Meneses L, Abreu P, Belonohy E, Lupelli I. Electron cyclotron emission spectra in X- and O-mode polarisation at JET: Martin-Puplett interferometer, absolute calibration, revised uncertainties, inboard/outboard temperature profile, and wall properties. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:093506. [PMID: 27782550 DOI: 10.1063/1.4962809] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
At the tokamak Joint European Torus (JET), the electron cyclotron emission spectra in O-mode and X-mode polarisations are diagnosed simultaneous in absolute terms for several harmonics with two Martin-Puplett interferometers. From the second harmonic range in X-mode polarisation, the electron temperature profile can be deduced for the outboard side (low magnetic field strength) of JET but only for some parts of the inboard side (high magnetic field strength). This spatial restriction can be bypassed, if a cutoff is not present inside the plasma for O-mode waves in the first harmonic range. Then, from this spectral domain, the profile on the entire inboard side is accessible. The profile determination relies on the new absolute and independent calibration for both interferometers. During the calibration procedure, the antenna pattern was investigated as well, and, potentially, an increase in the diagnostic responsivity of about 5% was found for the domain 100-300 GHz. This increase and other uncertainty sources are taken into account in the thorough revision of the uncertainty for the diagnostic absolute calibration. The uncertainty deduced and the convolution inherent for Fourier spectroscopy diagnostics have implications for the temperature profile inferred. Having probed the electron cyclotron emission spectra in orthogonal polarisation directions for the first harmonic range, a condition is derived for the reflection and polarisation-scrambling coefficients of the first wall on the outboard side of JET.
Collapse
Affiliation(s)
- S Schmuck
- CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom
| | - J Fessey
- CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom
| | - J E Boom
- Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, D-85748 Garching, Germany
| | - L Meneses
- Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - P Abreu
- Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - E Belonohy
- Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, D-85748 Garching, Germany
| | - I Lupelli
- CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom
| |
Collapse
|
6
|
Schmuck S, Fessey J, Gerbaud T, Alper B, Beurskens MNA, de la Luna E, Sirinelli A, Zerbini M. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:125101. [PMID: 23282107 DOI: 10.1063/1.4768246] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron temperature is determined from the measurements. The current state of the interferometer hardware, the calibration setup, and the analysis technique for calibration and plasma operation are described. A new, full-system, absolute calibration employing continuous data acquisition has been performed recently and the calibration method and results are presented. The noise level in the measurement is very low and as a result the electron cyclotron emission spectrum and thus the spatial profile of the electron temperature are determined to within ±5% and in the most relevant region to within ±2%. The new calibration shows that the absolute response of the system has decreased by about 15% compared to that measured previously and possible reasons for this change are presented. Temperature profiles measured with the Michelson interferometer are compared with profiles measured independently using Thomson scattering diagnostics, which have also been recently refurbished and recalibrated, and agreement within experimental uncertainties is obtained.
Collapse
Affiliation(s)
- S Schmuck
- Max-Planck-Institut fuer Plasmaphysik, Teilinsitut Greifswald, EURATOM-Assoziation, D-17491 Greifswald, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Yang ZJ, Phillips PE, Zhuang G, Xiao JS, Huang H, Rowan WL, Wang ZJ. A 16-channel heterodyne electron cyclotron emission radiometer on J-TEXT. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:10E313. [PMID: 23126973 DOI: 10.1063/1.4732069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
To study equilibrium temporal dynamics and the mechanisms of magnetohydrodynamic instabilities, a 16-channel heterodyne electron cyclotron emission (ECE) radiometer has been developed to view the J-TEXT tokamak from the low field side. The ECE radiometer detects second-harmonic extraordinary mode in the frequency band of 94-125 GHz which corresponds to resonances from 1.8 T to 2.2 T. This ECE system consists of an ECE transmission line, a radio frequency unit, and two 8-channel intermediate frequency units. An in situ blackbody calibration source is applied for system calibration by comparison of hot and cold sources in order to provide an absolute temperature measurement.
Collapse
Affiliation(s)
- Z J Yang
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | | | | | | | | | | | | |
Collapse
|
8
|
Simonetto A, Sozzi C, Garavaglia S, Fessey JA, Nowak S. A fast multichannel Martin-Puplett interferometer for electron cyclotron emission measurements on JET. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2011; 82:113506. [PMID: 22133575 DOI: 10.1063/1.3660276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A Martin Puplett interferometer for electron cyclotron emission (ECE) measurements from JET tokamak plasmas was extended to multichannel operation for simultaneous radial and oblique ECE measurements. This paper describes the new optics and the instrument's performance.
Collapse
Affiliation(s)
- A Simonetto
- Istituto di Fisica del Plasma CNR, Euratom-ENEA-CNR Association, 20125 Milano, Italy
| | | | | | | | | |
Collapse
|