1
|
Kreager BC, Wu H, Chang WY, Moon S, Mitchell J, Peng C, Huang CC, Muller M, Tian J, Jiang X. High-Performance PMN-PT Single-Crystal-Based 1-3 Composite Transducer Integrated with a Biopsy Needle. BIOSENSORS 2024; 14:74. [PMID: 38391993 PMCID: PMC10887013 DOI: 10.3390/bios14020074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 01/25/2024] [Accepted: 01/29/2024] [Indexed: 02/24/2024]
Abstract
To address the need for high-resolution imaging in lung nodule detection and overcome the limitations of the shallow imaging depth associated with high-frequency ultrasound and the complex structure of lung tissue, we successfully integrated 50 MHz ultrasound transducers with 18-gauge biopsy needles. Featuring a miniaturized size of 0.6 × 0.5 × 0.5 mm3, the 50 MHz micromachined 1-3 composite transducer was tested to perform mechanical scanning of a nodule within a lung-tissue-mimicking phantom in vitro. The high-frequency transducer demonstrated the ability to achieve imaging with an axial resolution of 30 μm for measuring nodule edges. Moreover, the integrated biopsy needle prototype exhibited high accuracy (1.74% discrepancy) in estimating nodule area compared to actual dimensions in vitro. These results underscore the promising potential of biopsy-needle-integrated transducers in enhancing the accuracy of endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNA) for clinical applications.
Collapse
Affiliation(s)
- Benjamin C. Kreager
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA; (B.C.K.); (H.W.); (S.M.); (J.M.); (M.M.)
| | - Huaiyu Wu
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA; (B.C.K.); (H.W.); (S.M.); (J.M.); (M.M.)
| | - Wei-Yi Chang
- CTS Advanced Materials, 4925 Indiana Ave, Lisle, IL 604532, USA; (W.-Y.C.); (J.T.)
| | - Sunho Moon
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA; (B.C.K.); (H.W.); (S.M.); (J.M.); (M.M.)
| | - Josh Mitchell
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA; (B.C.K.); (H.W.); (S.M.); (J.M.); (M.M.)
| | - Chang Peng
- School of Biomedical Engineering, ShanghaiTech University, Shanghai 201210, China;
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan;
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA; (B.C.K.); (H.W.); (S.M.); (J.M.); (M.M.)
| | - Jian Tian
- CTS Advanced Materials, 4925 Indiana Ave, Lisle, IL 604532, USA; (W.-Y.C.); (J.T.)
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA; (B.C.K.); (H.W.); (S.M.); (J.M.); (M.M.)
| |
Collapse
|
2
|
Trinh XT, Jeng JT, Nguyen HT, Luong VS, Lu CC. Two-Dimensional Position Tracking Using Gradient Magnetic Fields. SENSORS (BASEL, SWITZERLAND) 2022; 22:5459. [PMID: 35891131 PMCID: PMC9321341 DOI: 10.3390/s22145459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 07/08/2022] [Accepted: 07/19/2022] [Indexed: 06/15/2023]
Abstract
In this work, a two-dimensional (2D) position-detection device using a single axis magnetic sensor combined with orthogonal gradient coils was designed and fabricated. The sensors used were an induction coil and a GMR spin-valve sensor GF807 from Sensitec Inc. The field profiles generated by the two orthogonal gradient coils were analyzed numerically to achieve the maximum linear range, which corresponded to the detection area of the tracking system. The two coils were driven by 1-kHz sine wave currents with a 90° phase difference to generate the fields with uniform gradients along the x- and y-axis in the plane of the tracking stage. The gradient fields were detected by a single-axis sensor incorporated with a digital dual-phase lock-in detector to retrieve the position information. A linearity correction algorithm was used to improve the location accuracy and to extend the linear range for position sensing. The mean positioning error was found to be 0.417 mm, corresponding to the relative error of 0.21% in the working range of 200 mm × 200 mm, indicating that the proposed tracking system is promising for applications requiring accurate control of the two-dimensional position.
Collapse
Affiliation(s)
- Xuan Thang Trinh
- Faculty of Mechanical Engineering, Hung Yen University of Technology and Education, Hungyen 160000, Vietnam;
| | - Jen-Tzong Jeng
- Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 807618, Taiwan;
| | - Huu-Thang Nguyen
- Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 807618, Taiwan;
| | - Van Su Luong
- Faculty of Electrical and Electronic Engineering, Phenikaa University, Hanoi 12116, Vietnam;
| | - Chih-Cheng Lu
- Institute of Mechatronics Engineering, National Taipei University of Technology, Taipei 106344, Taiwan;
| |
Collapse
|
3
|
Marques MJ, Hughes MR, Uceda AF, Gelikonov G, Bradu A, Podoleanu A. Endoscopic en-face optical coherence tomography and fluorescence imaging using correlation-based probe tracking. BIOMEDICAL OPTICS EXPRESS 2022; 13:761-776. [PMID: 35284172 PMCID: PMC8884237 DOI: 10.1364/boe.444170] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 12/20/2021] [Accepted: 12/21/2021] [Indexed: 05/25/2023]
Abstract
Forward-viewing endoscopic optical coherence tomography (OCT) provides 3D imaging in vivo, and can be combined with widefield fluorescence imaging by use of a double-clad fiber. However, it is technically challenging to build a high-performance miniaturized 2D scanning system with a large field-of-view. In this paper we demonstrate how a 1D scanning probe, which produces cross-sectional OCT images (B-scans) and 1D fluorescence T-scans, can be transformed into a 2D scanning probe by manual scanning along the second axis. OCT volumes are assembled from the B-scans using speckle decorrelation measurements to estimate the out-of-plane motion along the manual scan direction. Motion within the plane of the B-scans is corrected using image registration by normalized cross correlation. En-face OCT slices and fluorescence images, corrected for probe motion in 3D, can be displayed in real-time during the scan. For a B-scan frame rate of 250 Hz, and an OCT lateral resolution of approximately 20 μ m , the approach can handle out-of-plane motion at speeds of up to 4 mm/s.
Collapse
Affiliation(s)
- Manuel J. Marques
- Applied Optics Group, Physics and Astronomy, Division of Natural Sciences, University of Kent, Canterbury CT2 7NH, United Kingdom
- Both authors contributed equally to this publication
| | - Michael R. Hughes
- Applied Optics Group, Physics and Astronomy, Division of Natural Sciences, University of Kent, Canterbury CT2 7NH, United Kingdom
- Both authors contributed equally to this publication
| | - Adrián F. Uceda
- Applied Optics Group, Physics and Astronomy, Division of Natural Sciences, University of Kent, Canterbury CT2 7NH, United Kingdom
| | | | - Adrian Bradu
- Applied Optics Group, Physics and Astronomy, Division of Natural Sciences, University of Kent, Canterbury CT2 7NH, United Kingdom
| | - Adrian Podoleanu
- Applied Optics Group, Physics and Astronomy, Division of Natural Sciences, University of Kent, Canterbury CT2 7NH, United Kingdom
| |
Collapse
|
4
|
Marsden M, Fukazawa T, Deng YC, Weyers BW, Bec J, Gregory Farwell D, Marcu L. FLImBrush: dynamic visualization of intraoperative free-hand fiber-based fluorescence lifetime imaging. BIOMEDICAL OPTICS EXPRESS 2020; 11:5166-5180. [PMID: 33014606 PMCID: PMC7510860 DOI: 10.1364/boe.398357] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 07/22/2020] [Accepted: 08/11/2020] [Indexed: 05/18/2023]
Abstract
A free-hand scanning approach to medical imaging allows for flexible, lightweight probes to image intricate anatomies for modalities such as fluorescence lifetime imaging (FLIm), optical coherence tomography (OCT) and ultrasound. While very promising, this approach faces several key challenges including tissue motion during imaging, varying lighting conditions in the surgical field, and sparse sampling of the tissue surface. These challenges limit the coregistration accuracy and interpretability of the acquired imaging data. Here we report FLImBrush as a robust method for the localization and visualization of intraoperative free-hand fiber optic fluorescence lifetime imaging (FLIm). FLImBrush builds upon an existing method while employing deep learning-based image segmentation, block-matching based motion correction, and interpolation-based visualization to address the aforementioned challenges. Current results demonstrate that FLImBrush can provide accurate localization of FLIm point-measurements while producing interpretable and complete visualizations of FLIm data acquired from a tissue surface. Each of the main processing steps was shown to be capable of real-time processing (> 30 frames per second), highlighting the feasibility of FLImBrush for intraoperative imaging and surgical guidance. Current findings show the feasibility of integrating FLImBrush into a range of surgical applications including cancer margins assessment during head and neck surgery.
Collapse
Affiliation(s)
- Mark Marsden
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
- Equal Contribution
| | - Takanori Fukazawa
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
- Sony Imaging Products and Solutions Inc., Japan
- Equal Contribution
| | - Yu-Cheng Deng
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
| | - Brent W Weyers
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
| | - Julien Bec
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
| | - D Gregory Farwell
- Department of Otolaryngology, University of California, Davis, CA 95817, USA
- Corresponding authors
| | - Laura Marcu
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
- Corresponding authors
| |
Collapse
|
5
|
Sanderson RW, Curatolo A, Wijesinghe P, Chin L, Kennedy BF. Finger-mounted quantitative micro-elastography. BIOMEDICAL OPTICS EXPRESS 2019; 10:1760-1773. [PMID: 31086702 PMCID: PMC6484987 DOI: 10.1364/boe.10.001760] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 01/17/2019] [Accepted: 02/05/2019] [Indexed: 05/14/2023]
Abstract
We present a finger-mounted quantitative micro-elastography (QME) probe, capable of measuring the elasticity of biological tissue in a format that avails of the dexterity of the human finger. Finger-mounted QME represents the first demonstration of a wearable elastography probe. The approach realizes optical coherence tomography-based elastography by focusing the optical beam into the sample via a single-mode fiber that is fused to a length of graded-index fiber. The fiber is rigidly affixed to a 3D-printed thimble that is mounted on the finger. Analogous to manual palpation, the probe compresses the tissue through the force exerted by the finger. The resulting deformation is measured using optical coherence tomography. Elasticity is estimated as the ratio of local stress at the sample surface, measured using a compliant layer, to the local strain in the sample. We describe the probe fabrication method and the signal processing developed to achieve accurate elasticity measurements in the presence of motion artifact. We demonstrate the probe's performance in motion-mode scans performed on homogeneous, bi-layer and inclusion phantoms and its ability to measure a thermally-induced increase in elasticity in ex vivo muscle tissue. In addition, we demonstrate the ability to acquire 2D images with the finger-mounted probe where lateral scanning is achieved by swiping the probe across the sample surface.
Collapse
Affiliation(s)
- Rowan W. Sanderson
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia, 6009, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia, 6009, Australia
| | - Andrea Curatolo
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia, 6009, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia, 6009, Australia
- Current address: Visual Optics and Biophotonics Group, Instituto de Óptica “Daza de Valdés”, Consejo Superior de Investigaciones Cientificas (IO, CSIC), C/Serrano, 121, Madrid 28006, Spain
| | - Philip Wijesinghe
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia, 6009, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia, 6009, Australia
- Current address: SUPA, School of Physics and Astronomy, University of St. Andrews, KY16 9SS, UK
| | - Lixin Chin
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia, 6009, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia, 6009, Australia
| | - Brendan F. Kennedy
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia, 6009, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia, 6009, Australia
| |
Collapse
|
6
|
Lee AMD, MacAulay C, Lane P. Depth-multiplexed optical coherence tomography dual-beam manually-actuated distortion-corrected imaging (DMDI) with a micromotor catheter. BIOMEDICAL OPTICS EXPRESS 2018; 9:5678-5690. [PMID: 30460155 PMCID: PMC6238937 DOI: 10.1364/boe.9.005678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Revised: 10/03/2018] [Accepted: 10/03/2018] [Indexed: 06/09/2023]
Abstract
We present a new micromotor catheter implementation of dual-beam manually-actuated distortion-corrected imaging (DMDI). The new catheter called a depth-multiplexed dual-beam micromotor catheter, or mDBMC, maintains the primary advantage of unlimited field-of-view distortion-corrected imaging along the catheter axis. The mDBMC uses a polarization beam splitter and cube mirror to create two beams that scan circularly with approximately constant separation at the catheter surface. This arrangement also multiplexes both imaging channels into a single optical coherence tomography channel by offsetting them in depth, requiring half the data bandwidth compared to previous DMDI demonstrations that used two parallel image acquisition systems. Furthermore, the relatively simple scanning pattern of the two beams enables a straightforward automated distortion correction algorithm. We demonstrate the imaging capabilities of this catheter with a printed paper phantom and in a section of dragon fruit.
Collapse
|
7
|
Schulz-Hildebrandt H, Pfeiffer T, Eixmann T, Lohmann S, Ahrens M, Rehra J, Draxinger W, König P, Huber R, Hüttmann G. High-speed fiber scanning endoscope for volumetric multi-megahertz optical coherence tomography. OPTICS LETTERS 2018; 43:4386-4389. [PMID: 30211870 DOI: 10.1364/ol.43.004386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We present a forward-viewing fiber scanning endoscope (FSE) for high-speed volumetric optical coherence tomography (OCT). The reduction in size of the probe was achieved by substituting the focusing optics by an all-fiber-based imaging system which consists of a combination of scanning single-mode fibers, a glass spacer, made from a step-index multi-mode fiber, and a gradient-index fiber. A lateral resolution of 11 μm was achieved at a working distance of 1.2 mm. The newly designed piezo-based FSE has an outer diameter of 1.6 mm and a rigid length of 13.5 mm. By moving the whole imaging optic in spirals for scanning the sample, the beam quality remains constant over the entire field of view with a diameter of 0.8 mm. The scanning frequency was adjusted to 1.22 kHz for use with a 3.28 MHz Fourier domain mode locked OCT system. Densely sampled volumes have been imaged at a rate of 6 volumes per second.
Collapse
|
8
|
Harlow M, MacAulay C, Lane P, Lee AMD. Dual-beam manually actuated distortion-corrected imaging (DMDI): two dimensional scanning with a single-axis galvanometer. OPTICS EXPRESS 2018; 26:18758-18772. [PMID: 30114048 DOI: 10.1364/oe.26.018758] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
We recently demonstrated a new two-dimensional imaging paradigm called dual-beam manually actuated distortion-corrected imaging (DMDI). This technique uses a single mechanical scanner and two spatially separated beams to determine relative sample velocity and simultaneously corrects image distortions due to manual actuation. DMDI was first demonstrated using a rotating dual-beam micromotor catheter. Here, we present a new implementation of DMDI using a single axis galvanometer to scan a pair of beams in approximately parallel lines onto a sample. Furthermore, we present a method for automated distortion correction based on frame co-registration between images acquired by the two beams. Distortion correction is possible for manually actuated motion both perpendicular and parallel to the galvanometer-scanned lines. Using en face OCT as the imaging modality, we demonstrate DMDI and the automated distortion correction algorithm for imaging a printed paper phantom, a dragon fruit, and a fingerprint.
Collapse
|
9
|
Lee AMD, Hohert G, Angkiriwang PT, MacAulay C, Lane P. Dual-beam manually-actuated distortion-corrected imaging (DMDI) with micromotor catheters. OPTICS EXPRESS 2017; 25:22164-22177. [PMID: 29041505 DOI: 10.1364/oe.25.022164] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 08/18/2017] [Indexed: 05/23/2023]
Abstract
We present a new paradigm for performing two-dimensional scanning called dual-beam manually-actuated distortion-corrected imaging (DMDI). DMDI operates by imaging the same object with two spatially-separated beams that are being mechanically scanned rapidly in one dimension with slower manual actuation along a second dimension. Registration of common features between the two imaging channels allows remapping of the images to correct for distortions due to manual actuation. We demonstrate DMDI using a 4.7 mm OD rotationally scanning dual-beam micromotor catheter (DBMC). The DBMC requires a simple, one-time calibration of the beam paths by imaging a patterned phantom. DMDI allows for distortion correction of non-uniform axial speed and rotational motion of the DBMC. We show the utility of this technique by demonstrating en face OCT image distortion correction of a manually-scanned checkerboard phantom and fingerprint scan.
Collapse
|
10
|
Pande P, Shelton RL, Monroy GL, Nolan RM, Boppart SA. Low-cost hand-held probe for depth-resolved low-coherence interferometry. BIOMEDICAL OPTICS EXPRESS 2017; 8:338-348. [PMID: 28101422 PMCID: PMC5231303 DOI: 10.1364/boe.8.000338] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 12/07/2016] [Accepted: 12/08/2016] [Indexed: 05/20/2023]
Abstract
We report on the development of a low-cost hand-held low-coherence interferometric imaging system based on the principle of linear optical coherence tomography (Linear OCT), a technique which was first proposed in the early 2000s as a simpler alternative to the conventional time-domain and Fourier-domain OCT. A bench-top implementation of the proposed technique is first presented and validated. The axial resolution, SNR, and sensitivity roll-of of the system was estimated to be 5.2 μm and 80 dB, and 3.7 dB over a depth of 0.15 mm, respectively. After validating the bench-top system, two hand-held probe implementations for contact-based imaging and in vivo human tympanic membrane imaging are presented. The performance of the proposed system was compared with a research-grade state-of-the-art Fourier-domain low coherence interferometry (LCI) system by imaging several biological and non-biological samples. The results of this study suggest that the proposed system might be a suitable choice for applications where imaging depth and SNR can be traded for lower cost and simpler optical design.
Collapse
Affiliation(s)
- Paritosh Pande
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Ryan L. Shelton
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Guillermo L. Monroy
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Ryan M. Nolan
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| |
Collapse
|
11
|
Pande P, Monroy GL, Nolan RM, Shelton RL, Boppart SA. Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging. JOURNAL OF SENSORS 2016; 2016:8154809. [PMID: 29033983 PMCID: PMC5636012 DOI: 10.1155/2016/8154809] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Hand-held optical coherence tomography (OCT) imaging probes offer flexibility to image sites that are otherwise challenging to access. While the majority of hand-held imaging probes utilize galvanometer- or MEMS-scanning mirrors to transversely scan the imaging beam, these probes are commonly limited to lateral fields-of-view (FOV) of only a few millimeters. The use of a freehand manually scanned probe can significantly increase the lateral FOV. However, using the traditional fixed-rate triggering scheme for data acquisition in a manually scanned probe results in imaging artifacts due to variations in the scan velocity of the imaging probe. These artifacts result in a structurally inaccurate image of the sample. In this paper, we present a sensor-based manual scanning technique for OCT imaging, where real-time feedback from an optical motion sensor is used to trigger data acquisition. This technique is able to circumvent the problem of motion artifacts during manual scanning by adaptively altering the trigger rate based on the instantaneous scan velocity, enabling OCT imaging over a large lateral FOV. The feasibility of the proposed technique is demonstrated by imaging several biological and nonbiological samples.
Collapse
Affiliation(s)
- Paritosh Pande
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Guillermo L. Monroy
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Ryan M. Nolan
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Ryan L. Shelton
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
12
|
Lee J, Chae Y, Ahn YC, Moon S. Ultra-thin and flexible endoscopy probe for optical coherence tomography based on stepwise transitional core fiber. BIOMEDICAL OPTICS EXPRESS 2015; 6:1782-96. [PMID: 26137380 PMCID: PMC4467695 DOI: 10.1364/boe.6.001782] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 04/09/2015] [Accepted: 04/16/2015] [Indexed: 05/18/2023]
Abstract
We present an ultra-thin fiber-body endoscopy probe for optical coherence tomography (OCT) which is based on a stepwise transitional core (STC) fiber. In a minimalistic design, our probe was made of spliced specialty fibers that could be directly used for beam probing optics without using a lens. In our probe, the OCT light delivered through a single-mode fiber was efficiently expanded to a large mode field of 24 μm diameter for a low beam divergence. The size of our probe was 85 μm in the probe's diameter while operated in a 160-μm thick protective tubing. Through theoretical and experimental analyses, our probe was found to exhibit various attractive features in terms of compactness, flexibility and reliability along with its excellent fabrication simplicity.
Collapse
Affiliation(s)
- Jangbeom Lee
- Department of Physics, Kookmin University, Seoul, 136-702,
South Korea
| | - Yugyeong Chae
- Department of Biomedical Engineering and Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan, 608-737,
South Korea
| | - Yeh-Chan Ahn
- Department of Biomedical Engineering and Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan, 608-737,
South Korea
| | - Sucbei Moon
- Department of Physics, Kookmin University, Seoul, 136-702,
South Korea
| |
Collapse
|
13
|
Liang K, Traverso G, Lee HC, Ahsen OO, Wang Z, Potsaid B, Giacomelli M, Jayaraman V, Barman R, Cable A, Mashimo H, Langer R, Fujimoto JG. Ultrahigh speed en face OCT capsule for endoscopic imaging. BIOMEDICAL OPTICS EXPRESS 2015; 6:1146-63. [PMID: 25909001 PMCID: PMC4399656 DOI: 10.1364/boe.6.001146] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Revised: 03/02/2015] [Accepted: 03/02/2015] [Indexed: 05/18/2023]
Abstract
Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.
Collapse
Affiliation(s)
- Kaicheng Liang
- Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA,
USA
| | - Giovanni Traverso
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge MA,
USA
- Division of Gastroenterology, Massachusetts General Hospital, Boston MA,
USA
- Harvard Medical School, Boston MA,
USA
| | - Hsiang-Chieh Lee
- Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA,
USA
| | - Osman Oguz Ahsen
- Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA,
USA
| | - Zhao Wang
- Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA,
USA
| | - Benjamin Potsaid
- Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA,
USA
- Advanced Imaging Group, Thorlabs Inc., Newton NJ,
USA
| | - Michael Giacomelli
- Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA,
USA
| | | | - Ross Barman
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge MA,
USA
| | - Alex Cable
- Advanced Imaging Group, Thorlabs Inc., Newton NJ,
USA
| | - Hiroshi Mashimo
- Harvard Medical School, Boston MA,
USA
- Veterans Affairs Boston Healthcare System, Boston MA,
USA
| | - Robert Langer
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge MA,
USA
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge MA,
USA
| | - James G. Fujimoto
- Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA,
USA
| |
Collapse
|
14
|
Wijesundara K, Zdanski C, Kimbell J, Price H, Iftimia N, Oldenburg AL. Quantitative upper airway endoscopy with swept-source anatomical optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2014; 5:788-99. [PMID: 24688814 PMCID: PMC3959831 DOI: 10.1364/boe.5.000788] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2013] [Revised: 02/03/2014] [Accepted: 02/03/2014] [Indexed: 05/15/2023]
Abstract
Minimally invasive imaging of upper airway obstructions in children and adults is needed to improve clinical decision-making. Toward this goal, we demonstrate an anatomical optical coherence tomography (aOCT) system delivered via a small-bore, flexible endoscope to quantify the upper airway lumen geometry. Helical scans were obtained from a proximally-scanned fiber-optic catheter of 820 μm outer diameter and >2 mm focal length. Coupled with a long coherence length wavelength-swept light source, the system exhibited an SNR roll-off of < 10 dB over a 10 mm range. Operating at 10 rotations/s, the average accuracy of segmented cross-sectional areas was found to be -1.4 ± 1.0%. To demonstrate the capability of this system, aOCT was performed on a pediatric airway phantom and on ex vivo swine trachea. The ability for quantitative endoscopy afforded by this system can aid in diagnosis, medical and surgical decision making, and predictive modeling of upper airway obstructive disorders.
Collapse
Affiliation(s)
- Kushal Wijesundara
- Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255, USA
| | - Carlton Zdanski
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7070, USA
| | - Julia Kimbell
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7070, USA
| | - Hillel Price
- Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255, USA
| | - Nicusor Iftimia
- Physical Sciences Inc., New England Business Center, Andover, MA 01810, USA
| | - Amy L. Oldenburg
- Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255, USA
- Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7513, USA
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7575, USA
| |
Collapse
|
15
|
McLaughlin RA, Yang X, Quirk BC, Lorenser D, Kirk RW, Noble PB, Sampson DD. Static and dynamic imaging of alveoli using optical coherence tomography needle probes. J Appl Physiol (1985) 2012; 113:967-74. [DOI: 10.1152/japplphysiol.00051.2012] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Imaging of alveoli in situ has for the most part been infeasible due to the high resolution required to discern individual alveoli and limited access to alveoli beneath the lung surface. In this study, we present a novel technique to image alveoli using optical coherence tomography (OCT). We propose the use of OCT needle probes, where the distal imaging probe has been miniaturized and encased within a hypodermic needle (as small as 30-gauge, outer diameter 310 μm), allowing insertion deep within the lung tissue with minimal tissue distortion. Such probes enable imaging at a resolution of ∼12 μm within a three-dimensional cylindrical field of view with diameter ∼1.5 mm centered on the needle tip. The imaging technique is demonstrated on excised lungs from three different species: adult rats, fetal sheep, and adult pigs. OCT needle probes were used to image alveoli, small bronchioles, and blood vessels, and results were matched to histological sections. We also present the first dynamic OCT images acquired with an OCT needle probe, allowing tracking of individual alveoli during simulated cyclical lung inflation and deflation.
Collapse
Affiliation(s)
- Robert A. McLaughlin
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Western Australia, Australia
| | - Xiaojie Yang
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Western Australia, Australia
| | - Bryden C. Quirk
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Western Australia, Australia
| | - Dirk Lorenser
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Western Australia, Australia
| | - Rodney W. Kirk
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Western Australia, Australia
| | - Peter B. Noble
- Centre for Neonatal Research and Education, School of Women's and Infants' Health, University of Western Australia, Crawley, Western Australia, Australia; and
| | - David D. Sampson
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, University of Western Australia, Crawley, Western Australia, Australia
- Centre for Microscopy, Characterisation and Analysis, University of Western Australia, Crawley Western Australia, Australia
| |
Collapse
|