1
|
Bekmurzayeva A, Nurlankyzy M, Abdossova A, Myrkhiyeva Z, Tosi D. All-fiber label-free optical fiber biosensors: from modern technologies to current applications [Invited]. BIOMEDICAL OPTICS EXPRESS 2024; 15:1453-1473. [PMID: 38495725 PMCID: PMC10942689 DOI: 10.1364/boe.515563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/16/2024] [Accepted: 01/26/2024] [Indexed: 03/19/2024]
Abstract
Biosensors are established as promising analytical tools for detecting various analytes important in biomedicine and environmental monitoring. Using fiber optic technology as a sensing element in biosensors offers low cost, high sensitivity, chemical inertness, and immunity to electromagnetic interference. Optical fiber sensors can be used in in vivo applications and multiplexed to detect several targets simultaneously. Certain configurations of optical fiber technology allow the detection of analytes in a label-free manner. This review aims to discuss recent advances in label-free optical fiber biosensors from a technological and application standpoint. First, modern technologies used to build label-free optical fiber-based sensors will be discussed. Then, current applications where these technologies are applied are elucidated. Namely, examples of detecting soluble cancer biomarkers, hormones, viruses, bacteria, and cells are presented.
Collapse
Affiliation(s)
- Aliya Bekmurzayeva
- National Laboratory Astana, Nazarbayev University, Astana, 010000, Kazakhstan
| | - Marzhan Nurlankyzy
- National Laboratory Astana, Nazarbayev University, Astana, 010000, Kazakhstan
- School of Engineering and Digital Sciences, Nazarbayev University, Astana, 010000, Kazakhstan
| | - Albina Abdossova
- School of Engineering and Digital Sciences, Nazarbayev University, Astana, 010000, Kazakhstan
| | - Zhuldyz Myrkhiyeva
- National Laboratory Astana, Nazarbayev University, Astana, 010000, Kazakhstan
- School of Sciences and Humanities, Nazarbayev University, Astana, 010000, Kazakhstan
| | - Daniele Tosi
- National Laboratory Astana, Nazarbayev University, Astana, 010000, Kazakhstan
- School of Engineering and Digital Sciences, Nazarbayev University, Astana, 010000, Kazakhstan
| |
Collapse
|
2
|
Wu X, Wang Y, Zhang J, Zhang Y, Rao X, Chen C, Liu H, Deng Y, Liao C, Smietana MJ, Chen GY, Liu L, Qu J, Wang Y. A D-Shaped Polymer Optical Fiber Surface Plasmon Resonance Biosensor for Breast Cancer Detection Applications. BIOSENSORS 2023; 14:15. [PMID: 38248392 PMCID: PMC10813458 DOI: 10.3390/bios14010015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/18/2023] [Accepted: 12/21/2023] [Indexed: 01/23/2024]
Abstract
Fiber-optic biosensors have garnered significant attention and witnessed rapid development in recent years owing to their remarkable attributes such as high sensitivity, immunity to electromagnetic interference, and real-time monitoring. They have emerged as a potential tool in the realm of biomarker detection for low-concentration and small molecules. In this paper, a portable and cost-effective optical fiber biosensor based on surface plasmon resonance for the early detection of breast cancer is demonstrated. By utilizing the aptamer human epidermal growth factor receptor 2 (HER2) as a specific biomarker for breast cancer, the presence of the HER2 protein can be detected through an antigen-antibody binding technique. The detection method was accomplished by modifying a layer of HER2 aptamer on the flat surface of a gold-coated D-shaped polymer optical fiber (core/cladding diameter 120/490 μm), of which the residual thickness after side-polishing was about 245 μm, the thickness of the coated gold layer was 50 nm, and the initial wavelength in pure water was around 1200 nm. For low-concentration detection of the HER2 protein, the device exhibited a wavelength shift of ~1.37 nm with a concentration of 1 μg/mL (e.g., 5.5 nM), which corresponded to a limit of detection of ~5.28 nM. Notably, the response time of the biosensor was measured to be as fast as 5 s. The proposed biosensor exhibits the potential for early detection of HER2 protein in initial cancer serum and offers a pathway to early prevention of breast cancer.
Collapse
Affiliation(s)
- Xun Wu
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Ying Wang
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
- Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China
| | - Jiaxiong Zhang
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Yunfang Zhang
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Xing Rao
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Chen Chen
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Han Liu
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Yubin Deng
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Changrui Liao
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
- Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China
| | - Mateusz Jakub Smietana
- Division of Microsystem & Electronic Materials Technology, Institute of Microelectronics & Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland
| | - George Yuhui Chen
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
- Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China
| | - Liwei Liu
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Junle Qu
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Yiping Wang
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen 518060, China
- Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
- Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China
| |
Collapse
|
3
|
Lobry M, Guyot C, Kinet D, Chah K, Caucheteur C. Plasmonic biosensing with tilted fiber Bragg gratings interrogated using a 512-pixel spectrometer. OPTICS LETTERS 2023; 48:976-979. [PMID: 36790993 DOI: 10.1364/ol.476445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Plasmonic tilted fiber Bragg gratings (TFBGs) are very efficient for fast, accurate, and minimally invasive biosensing. Their transmitted amplitude spectrum is a dense comb of narrowband cladding mode resonances (full width at half maximum < 1 nm) that is usually demodulated using highly resolved (wavelength resolution < 10 pm) devices. This work demonstrates the possibility of using a coarsely resolved spectrometer (166 pm) to read out the amplitude spectrum of a gold-coated TFBG. A refined analysis of the spectral content has allowed us to develop signal processing that provides a refractometric sensitivity of 2656 nm/RIU. This is a fivefold improvement compared to previously reported read-out techniques. Biosensing has then been successfully implemented with gold-coated TFBGs implemented in reflection mode for the detection of insulin, with specific antibodies grafted on the gold surface. Our experimental work is a first step toward the industrialization of the FBG technology, as it opens the door to fast parallel biosensing, profiting from the multiple sensing channels (up to 64) of the interrogator and its high processing speed (repetition rate up to 3 kHz).
Collapse
|
4
|
Saha B, Goswami N, Saha A. Wave-theory-based analysis of a fiber optic bio-sensor illuminated by radially polarized Bessel-Gauss beam: an approach for early diagnosis of breast cancer with a high-resolution wavelength-interrogation technique. APPLIED OPTICS 2022; 61:10408-10417. [PMID: 36607099 DOI: 10.1364/ao.471283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 11/05/2022] [Indexed: 06/17/2023]
Abstract
With the establishment of validity using authoritative experimental results, an analytical investigation of an SPR-based fiber optic sensor, employing a wave-theory-based technique for determining breast cancer by shining a radially polarized Bessel-Gauss (RPBG) beam, is proposed. First, by using a radially polarized Gaussian (RPG) beam, the observed sensitivity is 9404.61 dB/RIU, where the acquired results are in good concurrence with the experimental data reported by Yan et al. [Chin. Opt. Lett.7, 909 (2009)COLHBT1671-7694]. Thus, the proposed theory has been validated with the reported experimental data. This theoretical analysis is further extended by utilizing an RPBG beam, where the observed sensitivity is 21,699.26 dB/RIU and 5846 nm/RIU, with a resolution of 4.61×10-7, which is 2.5 times superior to the reported results to date. By using an RPBG beam, the proposed method, to our best knowledge, is the first to achieve much higher sensitivity in the area of fiber optic breast cancer detection. The higher sensitivity achieved at lower concentrations of an HER2 biomarker has led to the idea of early diagnosis of breast cancer by optically assessing it at its earlier stage using a high-resolution wavelength-interrogation technique.
Collapse
|
5
|
Lobry M, Loyez M, Debliquy M, Chah K, Goormaghtigh E, Caucheteur C. Electro-plasmonic-assisted biosensing of proteins and cells at the surface of optical fiber. Biosens Bioelectron 2022; 220:114867. [DOI: 10.1016/j.bios.2022.114867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 10/16/2022] [Accepted: 10/27/2022] [Indexed: 11/16/2022]
|
6
|
Li D, Weng C, Chen C, Li K, Lin Q, Ruan Y, Zhang J, Wang S, Yao J. Optical biosensor based on weak value amplification for the high sensitivity detection of Pertuzumab in combination with Trastuzumab binding to the extracellular domain of HER2. OPTICS EXPRESS 2022; 30:36839-36848. [PMID: 36258605 DOI: 10.1364/oe.472012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Accepted: 09/04/2022] [Indexed: 06/16/2023]
Abstract
A real-time optical phase sensing scheme based on weak value amplification was proposed to monitor the especially binding process of Pertuzumab combined with Trastuzumab on HER2 positive cells. From the wavelength shift of output spectrum, the phase difference between measuring and referential path related to the concentration of Pertuzumab as well as Trastuzumab could be calculated. With this approach, the limit of detection (LOD) of 5.54 × 10-13 M for Pertuzumab assay was achieved. Besides, the kinetics signal of Pertuzumab in combination with Trastuzumab binding to HER2 was detected in real time. Experimental results demonstrated that both Trastuzumab and Pertuzumab can be captured by HER2, but the former was significantly superior to the latter in terms of the target number. Additionally, the binding speed was analyzed and demonstrated to be closely correlated with the initial concentration of the targeting agents.
Collapse
|
7
|
Sypabekova M, Amantayeva A, Vangelista L, González-Vila Á, Caucheteur C, Tosi D. Ultralow Limit Detection of Soluble HER2 Biomarker in Serum with a Fiber-Optic Ball-Tip Resonator Assisted by a Tilted FBG. ACS MEASUREMENT SCIENCE AU 2022; 2:309-316. [PMID: 36785571 PMCID: PMC9885947 DOI: 10.1021/acsmeasuresciau.2c00008] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
An optical-fiber biosensor has been developed for the detection of the breast cancer biomarker soluble human epidermal growth factor receptor-2 (sHER2). The sensor was fabricated by combining a tilted fiber Bragg grating (TFBG) with a ball resonator, allowing us to achieve an excellent sensitivity compared to other optical-fiber-based sensors. The sensor exhibits a resonance comb excited by the TFBG and the spectral profile of the ball resonator. The detection of sHER2 at extremely low concentrations was carried out by tracking the amplitude change of selected resonances. The therapeutic anti-HER2 monoclonal antibody Trastuzumab has been used to functionalize the biosensor with silane surface chemistry. The sensor features a sensitivity of 4034 dB/RIU with a limit of detection (LoD) in buffer and in a 1/10 diluted serum of 151.5 ag/mL and 3.7 pg/mL, respectively. At relatively high protein concentrations (64 ng/mL) binding to sHER (7.36 dB) as compared to control proteins (below 0.7 dB) attested the high specificity of sHER2 detection.
Collapse
Affiliation(s)
- Marzhan Sypabekova
- Nazarbayev
University School of Medicine, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan
- Nazarbayev
University School of Engineering and Digital Sciences, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan
- Baylor
Research and Innovative Collaborative, Baylor
University, 100 Research
Pkwy, Waco, Texas 76704, United States
| | - Aida Amantayeva
- Nazarbayev
University School of Engineering and Digital Sciences, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan
| | - Luca Vangelista
- Nazarbayev
University School of Medicine, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan
| | - Álvaro González-Vila
- Electromagnetism
and Telecommunication Department, University
of Mons, Boulevard Dolez 31, 7000 Mons, Belgium
| | - Christophe Caucheteur
- Electromagnetism
and Telecommunication Department, University
of Mons, Boulevard Dolez 31, 7000 Mons, Belgium
| | - Daniele Tosi
- Nazarbayev
University School of Engineering and Digital Sciences, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan
- National
Laboratory Astana, Laboratory of Biosensors and Bioinstruments, 010000 Nur-Sultan, Kazakhstan
| |
Collapse
|
8
|
Sharma AK, Kumar P, Prajapati YK. Plasmonics-based gas sensor with photonic spin hall effect in broad terahertz frequency range under variable chemical potential of graphene. OPTICAL AND QUANTUM ELECTRONICS 2022; 54:328. [PMID: 35578635 PMCID: PMC9096770 DOI: 10.1007/s11082-022-03626-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 02/22/2022] [Indexed: 06/15/2023]
Abstract
UNLABELLED Graphene monolayer of sub-nanometer thickness possesses strong metallic and plasmonic behavior in a broad terahertz (THz) frequency range. This plasmonic effect can be considerably manipulated when graphene layer is subjected to a variable chemical potential (Ef) via chemical doping or electrical gating. The strong adsorption characteristics of graphene layer is another important advantage. In this work, a photonic spin Hall effect (PSHE) based plasmonic sensor consisting of germanium prism, organic dielectric layer, and graphene monolayer is simulated and analyzed in THz range aiming at highly sensitive and reliable gas sensing. Modified Otto configuration and Kubo formulation for graphene at room temperature are considered. The sensor's performance is examined in terms of figure of merit (FOM). The analysis indicates that under angular interrogation scheme of sensor operation, the FOM improves for smaller chemical potential (moderate doping) and higher THz frequency. Moreover, the influence of temperature on gas sensor's performance (FOM) is negligible, which suggests that the sensor is capable of providing stable sensing performance against temperature variation. The sensor design is highly flexible in terms of selection of THz frequency as an alternative interrogation scheme (i.e., measuring the variation in spin-dependent shift peak value of PSHE spectrum upon change in gas medium refractive index) can also be implemented. It is found that there is no need to change the moderate doping of graphene monolayer (i.e., Ef remains around its normal value ~ 0.1 eV) as the sensitivity achievable with this alternative method has considerably greater magnitude at smaller THz frequency (e.g., 2 THz). The magnitudes of FOM (with angular interrogation method) and sensitivity (with alternative method) are found to be significantly greater for rarer gaseous media, which might possibly assist in early detection of airborne viruses such as SARS-Cov-2 (while using appropriate specificity method) and to measure the concentration of a particular gas in a given gaseous mixture. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s11082-022-03626-7.
Collapse
Affiliation(s)
- Anuj K. Sharma
- Physics Division, Department of Applied Sciences, National Institute of Technology (NIT) Delhi, GT Karnal Road, Delhi, 110036 India
| | - Parmod Kumar
- Physics Division, Department of Applied Sciences, National Institute of Technology (NIT) Delhi, GT Karnal Road, Delhi, 110036 India
| | | |
Collapse
|
9
|
Cladding Mode Fitting-Assisted Automatic Refractive Index Demodulation Optical Fiber Sensor Probe Based on Tilted Fiber Bragg Grating and SPR. SENSORS 2022; 22:s22083032. [PMID: 35459016 PMCID: PMC9032900 DOI: 10.3390/s22083032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 04/02/2022] [Accepted: 04/11/2022] [Indexed: 02/01/2023]
Abstract
In the paper based on surface plasmon resonance (SPR) in a tilted fiber Bragg grating (TFBG), a novel algorithm is proposed, which facilitates demodulation of surrounding refractive index (SRI) via cladding mode interrogation and accelerates calibration and measurement of SRI. Refractive indices with a tiny index step of 2.2 × 10−5 are prepared by the dilution of glucose aqueous solution for the test and the calibration of this fiber sensor probe. To accelerate the calibration process, automatic selection of the most sensitive cladding mode is demonstrated. First, peaks of transmitted spectrum are identified and numbered. Then, sensitivities of several potentially sensitive cladding modes in amplitude adjacent to the left of the SPR area are calculated and compared. After that, we focus on the amplitudes of the cladding modes as a function of a SRI, and the highest sensitivity of −6887 dB/RIU (refractive index unit) is obtained with a scanning time of 15.77 s in the range from 1520 nm to 1620 nm. To accelerate the scanning speed of the optical spectrum analyzer (OSA), the wavelength resolution is reduced from 0.028 nm to 0.07 nm, 0.14 nm, and 0.28 nm, and consequently the scanning time is shortened to 6.31 s, 3.15 s, and 1.58 s, respectively. However, compared to 0.028 nm, the SRI sensitivity for 0.07 nm, 0.14 nm, and 0.28 nm is reduced to −5685 dB/RIU (17.5% less), −5415 dB/RIU (21.4% less), and −4359 dB/RIU (36.7% less), respectively. Thanks to the calculation of parabolic equation and weighted Gauss fitting based on the original data, the sensitivity is improved to −6332 dB/RIU and −6721 dB/RIU, respectively, for 0.07 nm, and the sensitivity is increased to −5850 dB/RIU and −6228 dB/RIU, respectively, for 0.14 nm.
Collapse
|
10
|
Chupradit S, Jasim SA, Bokov D, Mahmoud MZ, Roomi AB, Hachem K, Rudiansyah M, Suksatan W, Bidares R. Recent advances in biosensor devices for HER-2 cancer biomarker detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1301-1310. [PMID: 35318477 DOI: 10.1039/d2ay00111j] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The human epidermal growth factor receptor 2 (HER-2) protein is a member of the epidermal growth factor receptor (EGFR or ErbB) family and is a transmembrane tyrosine kinase receptor. HER-2 is highly regulated in ovarian, lung, gastric, oral, and breast cancers. The low specificity, complexity, expensiveness and the lack of sensitivity are essential restrictions in traditional diagnosis methods such as FISH, immunohistochemistry and PCR and these disadvantages led to the need for more studies on alternative methods. Biosensor technology has greatly affected the quality of human life owing to its features including, sensitivity, specificity, and rapid diagnosis and monitoring of different patient diseases. In this review article, we examine various biosensors, considering that they have been categorized based on the transducers used including piezoelectric biosensors, optical sensors such as fluorescence and surface plasmon resonance, and electrochemical types for the diagnosis of HER-2 and the effectiveness of some drugs against that. Attention to developing some types of biosensor devices such as colorimetric biosensors for HER-2 detection can be an important point in future studies.
Collapse
Affiliation(s)
- Supat Chupradit
- Department of Occupational Therapy, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, 50200, Thailand
| | | | - Dmitry Bokov
- Institute of Pharmacy, Sechenov First Moscow State Medical University, 8 Trubetskaya St., Bldg. 2, Moscow, 119991, Russian Federation
- Laboratory of Food Chemistry, Federal Research Center of Nutrition, Biotechnology and Food Safety, 2/14 Ustyinsky pr., Moscow, 109240, Russian Federation
| | - Mustafa Z Mahmoud
- Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia
- Faculty of Health, University of Canberra, Canberra, ACT, Australia
| | - Ali B Roomi
- PhD Biochemistry, Ministry of Education, Directorate of Education Thi-Qar, Thi-Qar, 64001, Iraq
- Biochemistry and Biological Engineering Research Group, Scientific Research Center, Al-Ayen University, Thi-Qar, 64001, Iraq
| | - Kadda Hachem
- Laboratory of Biotoxicology, Pharmacognosy and Biological Valorization of Plants (LBPVBP), Faculty of Sciences, University of Saida - Dr Moulay Tahar, 20000 Saida, Algeria
| | - Mohammad Rudiansyah
- Division of Nephrology & Hypertension, Department of Internal Medicine, Faculty of Medicine, Universitas Lambung Mangkurat, Banjarmasin, Indonesia
| | - Wanich Suksatan
- Faculty of Nursing, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, 10210, Thailand
| | - Ramtin Bidares
- Department of Anatomy, Histology Forensic Medicine, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
11
|
Optimization of Cladding Diameter for Refractive Index Sensing in Tilted Fiber Bragg Gratings. SENSORS 2022; 22:s22062259. [PMID: 35336430 PMCID: PMC8953173 DOI: 10.3390/s22062259] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 03/07/2022] [Accepted: 03/14/2022] [Indexed: 12/20/2022]
Abstract
This work presents an experimental investigation of the effect of chemical etching on the refractive index (RI) sensitivity of tilted fiber Bragg gratings (TFBGs). Hydrofluoric acid (HF) was used stepwise in order to reduce the optical fiber diameter from 125 µm to 13 µm. After each etching step, TFBGs were calibrated using two ranges of RI solutions: the first one with high RI variation (from 1.33679 RIU to 1.37078 RIU) and the second with low RI variation (from 1.34722 RIU to 1.34873 RIU). RI sensitivity was analyzed in terms of wavelength shift and intensity change of the grating resonances. The highest amplitude sensitivities obtained are 1008 dB/RIU for the high RI range and 8160 dB/RIU for the low RI range, corresponding to the unetched TFBG. The highest wavelength sensitivities are 38.8 nm/RIU for a fiber diameter of 100 µm for the high RI range, and 156 nm/RIU for a diameter of 40 µm for the small RI range. In addition, the effect of the etching process on the spectral intensity of the cladding modes, their wavelength separation and sensor linearity (R2) were studied as well. As a result, an optimization of the etching process is provided, so that the best trade-off between sensitivity, intensity level, and fiber thickness can be obtained.
Collapse
|
12
|
Vidal M, Soares MS, Loyez M, Costa FM, Caucheteur C, Marques C, Pereira SO, Leitão C. Relevance of the Spectral Analysis Method of Tilted Fiber Bragg Grating-Based Biosensors: A Case-Study for Heart Failure Monitoring. SENSORS 2022; 22:s22062141. [PMID: 35336312 PMCID: PMC8954114 DOI: 10.3390/s22062141] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 02/23/2022] [Accepted: 03/08/2022] [Indexed: 01/16/2023]
Abstract
Optical fiber technology has rapidly progressed over the years, providing valuable benefits for biosensing purposes such as sensor miniaturization and the possibility for remote and real-time monitoring. In particular, tilted fiber Bragg gratings (TFBGs) are extremely sensitive to refractive index variations taking place on their surface. The present work comprises a case-study on the impact of different methods of analysis applied to decode spectral variations of bare and plasmonic TFBGs during the detection of N-terminal B-type natriuretic peptide (NT-proBNP), a heart failure biomarker, namely by following the most sensitive mode, peaks of the spectral envelopes, and the envelopes’ crossing point and area. Tracking the lower envelope resulted in the lowest limits of detection (LOD) for bare and plasmonic TFBGs, namely, 0.75 ng/mL and 0.19 ng/mL, respectively. This work demonstrates the importance of the analysis method on the outcome results, which is crucial to attain the most reliable and sensitive method with lower LOD sensors. Furthermore, it makes the scientific community aware to take careful attention when comparing the performance of different biosensors in which different analysis methods were used.
Collapse
Affiliation(s)
- Miguel Vidal
- Physics Department & I3N, University of Aveiro, 3810-193 Aveiro, Portugal; (M.V.); (M.S.S.); (F.M.C.); (C.M.); (S.O.P.)
| | - Maria Simone Soares
- Physics Department & I3N, University of Aveiro, 3810-193 Aveiro, Portugal; (M.V.); (M.S.S.); (F.M.C.); (C.M.); (S.O.P.)
| | - Médéric Loyez
- Electromagnetism and Telecommunication Department, University of Mons, 31 Bld Dolez, 7000 Mons, Belgium; (M.L.); (C.C.)
| | - Florinda M. Costa
- Physics Department & I3N, University of Aveiro, 3810-193 Aveiro, Portugal; (M.V.); (M.S.S.); (F.M.C.); (C.M.); (S.O.P.)
| | - Christophe Caucheteur
- Electromagnetism and Telecommunication Department, University of Mons, 31 Bld Dolez, 7000 Mons, Belgium; (M.L.); (C.C.)
| | - Carlos Marques
- Physics Department & I3N, University of Aveiro, 3810-193 Aveiro, Portugal; (M.V.); (M.S.S.); (F.M.C.); (C.M.); (S.O.P.)
| | - Sónia O. Pereira
- Physics Department & I3N, University of Aveiro, 3810-193 Aveiro, Portugal; (M.V.); (M.S.S.); (F.M.C.); (C.M.); (S.O.P.)
| | - Cátia Leitão
- Physics Department & I3N, University of Aveiro, 3810-193 Aveiro, Portugal; (M.V.); (M.S.S.); (F.M.C.); (C.M.); (S.O.P.)
- Correspondence:
| |
Collapse
|
13
|
Sousa DA, Carneiro M, Ferreira D, Moreira FTC, Sales MGFV, Rodrigues LR. Recent advances in the selection of cancer-specific aptamers for the development of biosensors. Curr Med Chem 2022; 29:5850-5880. [PMID: 35209816 DOI: 10.2174/0929867329666220224155037] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 11/30/2021] [Accepted: 12/19/2021] [Indexed: 11/22/2022]
Abstract
An early diagnosis has the potential to greatly decrease cancer mortality. For that purpose, specific cancer biomarkers have been molecularly targeted by aptamer sequences to enable an accurate and rapid detection. Aptamer-based biosensors for cancer diagnostics are a promising alternative to those using antibodies, due to their high affinity and specificity to the target molecules and advantageous production. Synthetic nucleic acid aptamers are generated by in vitro Systematic Evolution of Ligands by Exponential enrichment (SELEX) methodologies that have been improved over the years to enhance the efficacy and to shorten the selection process. Aptamers have been successfully applied in electrochemical, optical, photoelectrochemical and piezoelectrical-based detection strategies. These aptasensors comprise a sensitive, accurate and inexpensive option for cancer detection being used as point-of-care devices. This review highlights the recent advances in cancer biomarkers, achievements and optimizations made in aptamer selection, as well as the different aptasensors developed for the detection of several cancer biomarkers.
Collapse
Affiliation(s)
- Diana A Sousa
- CEB- Centre of Biological Engineering, University of Minho, Campus de Gualtar, Braga, Portugal
- MIT-Portugal Program, Lisbon, Portugal
| | - Mariana Carneiro
- CEB- Centre of Biological Engineering, University of Minho, Campus de Gualtar, Braga, Portugal
- BioMark@ISEP, School of Engineering, Polytechnic of Porto, Porto, Portugal
| | - Débora Ferreira
- CEB- Centre of Biological Engineering, University of Minho, Campus de Gualtar, Braga, Portugal
- MIT-Portugal Program, Lisbon, Portugal
| | - Felismina T C Moreira
- CEB- Centre of Biological Engineering, University of Minho, Campus de Gualtar, Braga, Portugal
- BioMark@ISEP, School of Engineering, Polytechnic of Porto, Porto, Portugal
| | - Maria Goreti F V Sales
- CEB- Centre of Biological Engineering, University of Minho, Campus de Gualtar, Braga, Portugal
- MIT-Portugal Program, Lisbon, Portugal
- BioMark@UC, Faculty of Sciences and Technology, University of Coimbra, Coimbra, Portugal
| | - Lígia R Rodrigues
- CEB- Centre of Biological Engineering, University of Minho, Campus de Gualtar, Braga, Portugal
| |
Collapse
|
14
|
In-Situ Li-Ion Pouch Cell Diagnostics Utilising Plasmonic Based Optical Fibre Sensors. SENSORS 2022; 22:s22030738. [PMID: 35161487 PMCID: PMC8838023 DOI: 10.3390/s22030738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 01/14/2022] [Accepted: 01/16/2022] [Indexed: 11/30/2022]
Abstract
As the drive to improve the cost, performance characteristics and safety of lithium-ion batteries increases with adoption, one area where significant value could be added is that of battery diagnostics. This paper documents an investigation into the use of plasmonic-based optical fibre sensors, inserted internally into 1.4 Ah lithium-ion pouch cells, as a real time and in-situ diagnostic technique. The successful implementation of the fibres inside pouch cells is detailed and promising correlation with battery state is reported, while having negligible impact on cell performance in terms of capacity and columbic efficiency. The testing carried out includes standard cycling and galvanostatic intermittent titration technique (GITT) tests, and the use of a reference electrode to correlate with the anode and cathode readings separately. Further observations are made around the sensor and analyte interaction mechanisms, robustness of sensors and suggested further developments. These finding show that a plasmonic-based optical fibre sensor may have potential as an opto-electrochemical diagnostic technique for lithium-ion batteries, offering an unprecedented view into internal cell phenomena.
Collapse
|
15
|
Loyez M, DeRosa MC, Caucheteur C, Wattiez R. Overview and emerging trends in optical fiber aptasensing. Biosens Bioelectron 2022; 196:113694. [PMID: 34637994 DOI: 10.1016/j.bios.2021.113694] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/30/2021] [Accepted: 10/01/2021] [Indexed: 12/16/2022]
Abstract
Optical fiber biosensors have attracted growing interest over the last decade and quickly became a key enabling technology, especially for the detection of biomarkers at extremely low concentrations and in small volumes. Among the many and recent fiber-optic sensing amenities, aptamers-based sensors have shown unequalled performances in terms of ease of production, specificity, and sensitivity. The immobilization of small and highly stable bioreceptors such as DNA has bolstered their use for the most varied applications e.g., medical diagnosis, food safety and environmental monitoring. This review highlights the recent advances in aptamer-based optical fiber biosensors. An in-depth analysis of the literature summarizes different fiber-optic structures and biochemical strategies for molecular detection and immobilization of receptors over diverse surfaces. In this review, we analyze the features offered by those sensors and discuss about the next challenges to be addressed. This overview investigates both biochemical and optical parameters, drawing the guiding lines for forthcoming innovations and prospects in this ever-growing field of research.
Collapse
Affiliation(s)
- Médéric Loyez
- Proteomics and Microbiology Department, University of Mons, Avenue du Champ de Mars 6, 7000, Mons, Belgium; Electromagnetism and Telecommunication Department, University of Mons, Bld. Dolez 31, 7000, Mons, Belgium.
| | - Maria C DeRosa
- Department of Chemistry, 203 Steacie Building, Carleton University, 1125, Colonel By Drive, Ottawa, ON K1S 5B6, Canada
| | - Christophe Caucheteur
- Electromagnetism and Telecommunication Department, University of Mons, Bld. Dolez 31, 7000, Mons, Belgium
| | - Ruddy Wattiez
- Proteomics and Microbiology Department, University of Mons, Avenue du Champ de Mars 6, 7000, Mons, Belgium
| |
Collapse
|
16
|
Brooks AK, Chakravarty S, Yadavalli VK. Flexible Sensing Systems for Cancer Diagnostics. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1379:275-306. [DOI: 10.1007/978-3-031-04039-9_11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
17
|
Loyez M, Wells M, Hambÿe S, Hubinon F, Blankert B, Wattiez R, Caucheteur C. PfHRP2 detection using plasmonic optrodes: performance analysis. Malar J 2021; 20:332. [PMID: 34320995 PMCID: PMC8320217 DOI: 10.1186/s12936-021-03863-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 07/23/2021] [Indexed: 12/11/2022] Open
Abstract
Background Early malaria diagnosis and its profiling require the development of new sensing platforms enabling rapid and early analysis of parasites in blood or saliva, aside the widespread rapid diagnostic tests (RDTs). Methods This study shows the performance of a cost-effective optical fiber-based solution to target the presence of Plasmodium falciparum histidine-rich protein 2 (PfHRP2). Unclad multimode optical fiber probes are coated with a thin gold film to excite Surface Plasmon Resonance (SPR) yielding high sensitivity to bio-interactions between targets and bioreceptors grafted on the metal surface. Results Their performances are presented in laboratory conditions using PBS spiked with growing concentrations of purified target proteins and within in vitro cultures. Two probe configurations are studied through label-free detection and amplification using secondary antibodies to show the possibility to lower the intrisic limit of detection. Conclusions As malaria hits millions of people worldwide, the improvement and multiplexing of this optical fiber technique can be of great interest, especially for a future purpose of using multiple receptors on the fiber surface or several coated-nanoparticles as amplifiers. Supplementary Information The online version contains supplementary material available at 10.1186/s12936-021-03863-3.
Collapse
Affiliation(s)
- Médéric Loyez
- Proteomics and Microbiology Department, University of Mons, Champ de Mars 6, 7000, Mons, Belgium. .,Electromagnetism and Telecommunications Department, University of Mons, Bld. Dolez 31, 7000, Mons, Belgium.
| | - Mathilde Wells
- Laboratory of Pharmaceutical Analysis, University of Mons, Avenue Maistriau 15, 7000, Mons, Belgium
| | - Stéphanie Hambÿe
- Laboratory of Pharmaceutical Analysis, University of Mons, Avenue Maistriau 15, 7000, Mons, Belgium
| | - François Hubinon
- Electromagnetism and Telecommunications Department, University of Mons, Bld. Dolez 31, 7000, Mons, Belgium
| | - Bertrand Blankert
- Laboratory of Pharmaceutical Analysis, University of Mons, Avenue Maistriau 15, 7000, Mons, Belgium
| | - Ruddy Wattiez
- Proteomics and Microbiology Department, University of Mons, Champ de Mars 6, 7000, Mons, Belgium
| | - Christophe Caucheteur
- Electromagnetism and Telecommunications Department, University of Mons, Bld. Dolez 31, 7000, Mons, Belgium
| |
Collapse
|
18
|
Ortega-Gomez A, Loyez M, Lobry M, Chah K, Zubia J, Villatoro J, Caucheteur C. Plasmonic sensors based on tilted Bragg gratings in multicore optical fibers. OPTICS EXPRESS 2021; 29:18469-18480. [PMID: 34154102 DOI: 10.1364/oe.430181] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 05/25/2021] [Indexed: 06/13/2023]
Abstract
Bare and gold-coated tilted fiber Bragg gratings (TFBGs) can nowadays be considered as a mature technology for volume and surface refractometric sensing, respectively. As for other technologies, a continuous effort is made towards the production of even more sensitive sensors, thereby enabling a high-resolution screening of the surroundings and the possible detection of rare events. To this aim, we study in this work the development of TFBG refractometers in 4-core fibers. In particular, we show that the refractometric sensitivity of the cut-off mode can reach 100 nm/RIU for a bare grating. Using another demodulation method, a tenfold sensitivity increase is obtained when tracking the extremum of the SPR (surface plasmon resonance) envelope for a gold-coated TFBG configuration. Immobilization of DNA probes was performed as a proof-of-concept to assess the high surface sensitivity of the device.
Collapse
|
19
|
Lee SB, Jung YJ, Choi HK, Sohn IB, Lee JH. Hybrid LPG-FBG Based High-Resolution Micro Bending Strain Sensor. SENSORS 2020; 21:s21010022. [PMID: 33375146 PMCID: PMC7792977 DOI: 10.3390/s21010022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 12/16/2020] [Accepted: 12/18/2020] [Indexed: 12/29/2022]
Abstract
Sensitivity and reliability are essential factors for the practical implementation of a wearable sensor. This study explores the possibility of using a hybrid high-resolution Bragg grating sensor for achieving a fast response to dynamic, continuous motion and Bragg signal pattern monitoring measurement. The wavelength shift pattern for real-time monitoring in picometer units was derived by using femtosecond laser Bragg grating processing on an optical wave path with long-period grating. The possibility of measuring the demodulation system's Bragg signal pattern on the reflection spectrum of the femtosecond laser precision Bragg process and the long-period grating was confirmed. By demonstrating a practical method of wearing the sensor, the application of wearables was also explored. It is possible to present the applicability of sophisticated micro transformation measurement applications in picometer units.
Collapse
Affiliation(s)
- Song-Bi Lee
- Department of Cognitive Science, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea;
| | - Young-Jun Jung
- Advanced Photonics Research Institute (APRI), Gwangju Institute of Science and Technology (GIST), 1 Oryong-dong, Buk-gu, Gwangju 500-712, Korea; (Y.-J.J.); (H.-K.C.); (I.-B.S.)
| | - Hun-Kook Choi
- Advanced Photonics Research Institute (APRI), Gwangju Institute of Science and Technology (GIST), 1 Oryong-dong, Buk-gu, Gwangju 500-712, Korea; (Y.-J.J.); (H.-K.C.); (I.-B.S.)
| | - Ik-Bu Sohn
- Advanced Photonics Research Institute (APRI), Gwangju Institute of Science and Technology (GIST), 1 Oryong-dong, Buk-gu, Gwangju 500-712, Korea; (Y.-J.J.); (H.-K.C.); (I.-B.S.)
| | - Joo-Hyeon Lee
- Department of Cognitive Science, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea;
- Correspondence:
| |
Collapse
|
20
|
Nath P, Kabir A, Khoubafarin Doust S, Kreais ZJ, Ray A. Detection of Bacterial and Viral Pathogens Using Photonic Point-of-Care Devices. Diagnostics (Basel) 2020; 10:diagnostics10100841. [PMID: 33086578 PMCID: PMC7603237 DOI: 10.3390/diagnostics10100841] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 10/05/2020] [Accepted: 10/15/2020] [Indexed: 12/15/2022] Open
Abstract
Infectious diseases caused by bacteria and viruses are highly contagious and can easily be transmitted via air, water, body fluids, etc. Throughout human civilization, there have been several pandemic outbreaks, such as the Plague, Spanish Flu, Swine-Flu, and, recently, COVID-19, amongst many others. Early diagnosis not only increases the chance of quick recovery but also helps prevent the spread of infections. Conventional diagnostic techniques can provide reliable results but have several drawbacks, including costly devices, lengthy wait time, and requirement of trained professionals to operate the devices, making them inaccessible in low-resource settings. Thus, a significant effort has been directed towards point-of-care (POC) devices that enable rapid diagnosis of bacterial and viral infections. A majority of the POC devices are based on plasmonics and/or microfluidics-based platforms integrated with mobile readers and imaging systems. These techniques have been shown to provide rapid, sensitive detection of pathogens. The advantages of POC devices include low-cost, rapid results, and portability, which enables on-site testing anywhere across the globe. Here we aim to review the recent advances in novel POC technologies in detecting bacteria and viruses that led to a breakthrough in the modern healthcare industry.
Collapse
|