Truzzi S, Manns F, Parel JM, Ruggeri M. Handheld contact-type OCT and color fundus system for retinal imaging. BIOMEDICAL OPTICS EXPRESS 2024; 15:2681-2696. [PMID: 38633089 PMCID: PMC11019701 DOI: 10.1364/boe.520735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 03/21/2024] [Accepted: 03/21/2024] [Indexed: 04/19/2024]
Abstract
We present proof of concept for a handheld contact-type system capable of simultaneous optical coherence tomography (OCT) imaging of the retina and wide-field digital fundus color photography. The study focuses on demonstrating the feasibility of the proposed approach, particularly for eventual use in pediatric patients during examination under anesthesia in the operating room and in the neonatal intensive care unit. Direct contact of the probe with the cornea allows the photographer to maintain a stable position during imaging, reducing motion artifacts in the OCT images. Additionally, it simplifies the alignment process and increases the field of view of the optics. By integrating OCT and fundus imaging into a single device, the proposed compact modular design eliminates the need for separate, space-consuming systems dedicated to each imaging modality.
Collapse
Affiliation(s)
- Stefano Truzzi
- Ophthalmic Biophysics Center, Bascom Palmer
Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Department of Engineering “Enzo
Ferrari”, University of Modena and Reggio Emilia, Modena, Italy
| | - Fabrice Manns
- Ophthalmic Biophysics Center, Bascom Palmer
Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, FL, USA
| | - Jean-Marie Parel
- Ophthalmic Biophysics Center, Bascom Palmer
Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, FL, USA
- Brien Holden Vision Institute, Sydney, NSW, Australia
| | - Marco Ruggeri
- Ophthalmic Biophysics Center, Bascom Palmer
Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, FL, USA
| |
Collapse
|
2
|
Gan F, Wu FP, Zhong YL. Artificial intelligence method based on multi-feature fusion for automatic macular edema (ME) classification on spectral-domain optical coherence tomography (SD-OCT) images. Front Neurosci 2023; 17:1097291. [PMID: 36793539 PMCID: PMC9922866 DOI: 10.3389/fnins.2023.1097291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 01/09/2023] [Indexed: 01/31/2023] Open
Abstract
Purpose A common ocular manifestation, macular edema (ME) is the primary cause of visual deterioration. In this study, an artificial intelligence method based on multi-feature fusion was introduced to enable automatic ME classification on spectral-domain optical coherence tomography (SD-OCT) images, to provide a convenient method of clinical diagnosis. Methods First, 1,213 two-dimensional (2D) cross-sectional OCT images of ME were collected from the Jiangxi Provincial People's Hospital between 2016 and 2021. According to OCT reports of senior ophthalmologists, there were 300 images with diabetic (DME), 303 images with age-related macular degeneration (AMD), 304 images with retinal-vein occlusion (RVO), and 306 images with central serous chorioretinopathy (CSC). Then, traditional omics features of the images were extracted based on the first-order statistics, shape, size, and texture. After extraction by the alexnet, inception_v3, resnet34, and vgg13 models and selected by dimensionality reduction using principal components analysis (PCA), the deep-learning features were fused. Next, the gradient-weighted class-activation map (Grad-CAM) was used to visualize the-deep-learning process. Finally, the fusion features set, which was fused from the traditional omics features and the deep-fusion features, was used to establish the final classification models. The performance of the final models was evaluated by accuracy, confusion matrix, and the receiver operating characteristic (ROC) curve. Results Compared with other classification models, the performance of the support vector machine (SVM) model was best, with an accuracy of 93.8%. The area under curves AUC of micro- and macro-averages were 99%, and the AUC of the AMD, DME, RVO, and CSC groups were 100, 99, 98, and 100%, respectively. Conclusion The artificial intelligence model in this study could be used to classify DME, AME, RVO, and CSC accurately from SD-OCT images.
Collapse
Affiliation(s)
- Fan Gan
- Medical College of Nanchang University, Nanchang, China,Department of Ophthalmology, Jiangxi Provincial People’s Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, China
| | - Fei-Peng Wu
- Department of Ophthalmology, Jiangxi Provincial People’s Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, China
| | - Yu-Lin Zhong
- Department of Ophthalmology, Jiangxi Provincial People’s Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, China,*Correspondence: Yu-Lin Zhong,
| |
Collapse
|
3
|
Guo S. CSGNet: Cascade semantic guided net for retinal vessel segmentation. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
4
|
Rank EA, Agneter A, Schmoll T, Leitgeb RA, Drexler W. Miniaturizing optical coherence tomography. TRANSLATIONAL BIOPHOTONICS 2022. [DOI: 10.1002/tbio.202100007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Affiliation(s)
- Elisabet A. Rank
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| | - Anja Agneter
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| | - Tilman Schmoll
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
- Carl Zeiss Meditec, Inc. Dublin California USA
| | - Rainer A. Leitgeb
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| |
Collapse
|
5
|
Leitgeb R, Placzek F, Rank E, Krainz L, Haindl R, Li Q, Liu M, Andreana M, Unterhuber A, Schmoll T, Drexler W. Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210150-PER. [PMID: 34672145 PMCID: PMC8528212 DOI: 10.1117/1.jbo.26.10.100601] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 09/23/2021] [Indexed: 05/17/2023]
Abstract
SIGNIFICANCE After three decades, more than 75,000 publications, tens of companies being involved in its commercialization, and a global market perspective of about USD 1.5 billion in 2023, optical coherence tomography (OCT) has become one of the fastest successfully translated imaging techniques with substantial clinical and economic impacts and acceptance. AIM Our perspective focuses on disruptive forward-looking innovations and key technologies to further boost OCT performance and therefore enable significantly enhanced medical diagnosis. APPROACH A comprehensive review of state-of-the-art accomplishments in OCT has been performed. RESULTS The most disruptive future OCT innovations include imaging resolution and speed (single-beam raster scanning versus parallelization) improvement, new implementations for dual modality or even multimodality systems, and using endogenous or exogenous contrast in these hybrid OCT systems targeting molecular and metabolic imaging. Aside from OCT angiography, no other functional or contrast enhancing OCT extension has accomplished comparable clinical and commercial impacts. Some more recently developed extensions, e.g., optical coherence elastography, dynamic contrast OCT, optoretinography, and artificial intelligence enhanced OCT are also considered with high potential for the future. In addition, OCT miniaturization for portable, compact, handheld, and/or cost-effective capsule-based OCT applications, home-OCT, and self-OCT systems based on micro-optic assemblies or photonic integrated circuits will revolutionize new applications and availability in the near future. Finally, clinical translation of OCT including medical device regulatory challenges will continue to be absolutely essential. CONCLUSIONS With its exquisite non-invasive, micrometer resolution depth sectioning capability, OCT has especially revolutionized ophthalmic diagnosis and hence is the fastest adopted imaging technology in the history of ophthalmology. Nonetheless, OCT has not been completely exploited and has substantial growth potential-in academics as well as in industry. This applies not only to the ophthalmic application field, but also especially to the original motivation of OCT to enable optical biopsy, i.e., the in situ imaging of tissue microstructure with a resolution approaching that of histology but without the need for tissue excision.
Collapse
Affiliation(s)
- Rainer Leitgeb
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Medical University of Vienna, Christian Doppler Laboratory OPTRAMED, Vienna, Austria
| | - Fabian Placzek
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Elisabet Rank
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Lisa Krainz
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Richard Haindl
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Qian Li
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Mengyang Liu
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Marco Andreana
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Angelika Unterhuber
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Tilman Schmoll
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Carl Zeiss Meditec, Inc., Dublin, California, United States
| | - Wolfgang Drexler
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Address all correspondence to Wolfgang Drexler,
| |
Collapse
|
6
|
Ringel MJ, Tang EM, Tao YK. Advances in multimodal imaging in ophthalmology. Ther Adv Ophthalmol 2021; 13:25158414211002400. [PMID: 35187398 PMCID: PMC8855415 DOI: 10.1177/25158414211002400] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 02/23/2021] [Indexed: 12/12/2022] Open
Abstract
Multimodality ophthalmic imaging systems aim to enhance the contrast, resolution, and functionality of existing technologies to improve disease diagnostics and therapeutic guidance. These systems include advanced acquisition and post-processing methods using optical coherence tomography (OCT), combined scanning laser ophthalmoscopy and OCT systems, adaptive optics, surgical guidance, and photoacoustic technologies. Here, we provide an overview of these ophthalmic imaging systems and their clinical and basic science applications.
Collapse
Affiliation(s)
- Morgan J. Ringel
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Eric M. Tang
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Yuankai K. Tao
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA
| |
Collapse
|
7
|
Wang D, Haytham A, Pottenburgh J, Saeedi O, Tao Y. Hard Attention Net for Automatic Retinal Vessel Segmentation. IEEE J Biomed Health Inform 2020; 24:3384-3396. [DOI: 10.1109/jbhi.2020.3002985] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
8
|
Mozaffari S, LaRocca F, Jaedicke V, Tiruveedhula P, Roorda A. Wide-vergence, multi-spectral adaptive optics scanning laser ophthalmoscope with diffraction-limited illumination and collection. BIOMEDICAL OPTICS EXPRESS 2020; 11:1617-1632. [PMID: 32206432 PMCID: PMC7075605 DOI: 10.1364/boe.384229] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 02/11/2020] [Accepted: 02/15/2020] [Indexed: 05/06/2023]
Abstract
Visualizing and assessing the function of microscopic retinal structures in the human eye is a challenging task that has been greatly facilitated by ophthalmic adaptive optics (AO). Yet, as AO imaging systems advance in functionality by employing multiple spectral channels and larger vergence ranges, achieving optimal resolution and signal-to-noise ratios (SNR) becomes difficult and is often compromised. While current-generation AO retinal imaging systems have demonstrated excellent, near diffraction-limited imaging performance over wide vergence and spectral ranges, a full theoretical and experimental analysis of an AOSLO that includes both the light delivery and collection optics has not been done, and neither has the effects of extending wavefront correction from one wavelength to imaging performance in different spectral channels. Here, we report a methodology and system design for simultaneously achieving diffraction-limited performance in both the illumination and collection paths for a wide-vergence, multi-spectral AO scanning laser ophthalmoscope (SLO) over a 1.2 diopter vergence range while correcting the wavefront in a separate wavelength. To validate the design, an AOSLO was constructed to have three imaging channels spanning different wavelength ranges (543 ± 11 nm, 680 ± 11 nm, and 840 ± 6 nm, respectively) and one near-infrared wavefront sensing channel (940 ± 5 nm). The AOSLO optics and their alignment were determined via simulations in optical and optomechanical design software and then experimentally verified by measuring the AOSLO's illumination and collection point spread functions (PSF) for each channel using a phase retrieval technique. The collection efficiency was then measured for each channel as a function of confocal pinhole size when imaging a model eye achieving near-theoretical performance. Imaging results from healthy human adult volunteers demonstrate the system's ability to resolve the foveal cone mosaic in all three imaging channels despite a wide spectral separation between the wavefront sensing and imaging channels.
Collapse
Affiliation(s)
- Sanam Mozaffari
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
- Contributed equally to this work
| | - Francesco LaRocca
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
- Contributed equally to this work
| | - Volker Jaedicke
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
| | - Pavan Tiruveedhula
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
| | - Austin Roorda
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
| |
Collapse
|
9
|
Damodaran M, Amelink A, Feroldi F, Lochocki B, Davidoiu V, de Boer JF. In vivo subdiffuse scanning laser oximetry of the human retina. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-14. [PMID: 31571433 PMCID: PMC6997660 DOI: 10.1117/1.jbo.24.9.096009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2019] [Accepted: 09/09/2019] [Indexed: 06/10/2023]
Abstract
Scanning laser ophthalmoscopes (SLOs) have the potential to perform high speed, high contrast, functional imaging of the human retina for diagnosis and follow-up of retinal diseases. Commercial SLOs typically use a monochromatic laser source or a superluminescent diode for imaging. Multispectral SLOs using an array of laser sources for spectral imaging have been demonstrated in research settings, with applications mainly aiming at retinal oxygenation measurements. Previous SLO-based oximetry techniques are predominantly based on wavelengths that depend on laser source availability. We describe an SLO system based on a supercontinuum (SC) source and a double-clad fiber using the single-mode core for illumination and the larger inner cladding for quasi-confocal detection to increase throughput and signal-to-noise ratio. A balanced detection scheme was implemented to suppress the relative intensity noise of the SC source. The SLO produced dual wavelength, high-quality images at 10 frames / s with a maximum 20 deg imaging field-of-view with any desired combination of wavelengths in the visible spectrum. We demonstrate SLO-based dual-wavelength oximetry in vessels down to 50 μm in diameter. Reproducibility was demonstrated by performing three different imaging sessions of the same volunteer, 8 min apart. Finally, by performing a wavelength sweep between 485 and 608 nm, we determined, for our SLO geometry, an approximately linear relationship between the effective path length of photons through the blood vessels and the vessel diameter.
Collapse
Affiliation(s)
- Mathi Damodaran
- Vrije Universiteit Amsterdam, LaserLaB, Department of Physics and Astronomy, Amsterdam, The Netherlands
| | - Arjen Amelink
- Netherlands Organization for Applied Scientific Research TNO, Department of Optics, Delft, The Netherlands
| | - Fabio Feroldi
- Vrije Universiteit Amsterdam, LaserLaB, Department of Physics and Astronomy, Amsterdam, The Netherlands
| | - Benjamin Lochocki
- Vrije Universiteit Amsterdam, LaserLaB, Department of Physics and Astronomy, Amsterdam, The Netherlands
| | - Valentina Davidoiu
- Vrije Universiteit Amsterdam, LaserLaB, Department of Physics and Astronomy, Amsterdam, The Netherlands
| | - Johannes F. de Boer
- Vrije Universiteit Amsterdam, LaserLaB, Department of Physics and Astronomy, Amsterdam, The Netherlands
- Amsterdam UMC, Ophthalmology Department, Amsterdam, The Netherlands
| |
Collapse
|
10
|
DuBose T, Nankivil D, LaRocca F, Waterman G, Hagan K, Polans J, Keller B, Tran-Viet D, Vajzovic L, Kuo AN, Toth CA, Izatt JA, Farsiu S. Handheld Adaptive Optics Scanning Laser Ophthalmoscope. OPTICA 2018; 5:1027-1036. [PMID: 31745495 PMCID: PMC6863352 DOI: 10.1364/optica.5.001027] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 07/24/2018] [Indexed: 05/11/2023]
Abstract
Adaptive optics scanning laser ophthalmoscopy (AOSLO) has enabled in vivo visualization and enhanced understanding of retinal structure and function. Current generation AOSLOs have a large footprint and are mainly limited to imaging cooperative adult subjects. To extend the application of AOSLO to new patient populations, we have designed the first portable handheld AOSLO (HAOSLO) system. By incorporating a novel computational wavefront sensorless AO algorithm and custom optics, we have miniaturized our HAOSLO to weigh less than 200 grams. HAOSLO imaged the cones closest to the fovea with a handheld probe in adults and captured the first AO-enhanced image of cones in infants.
Collapse
Affiliation(s)
- Theodore DuBose
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Derek Nankivil
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Francesco LaRocca
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Gar Waterman
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Kristen Hagan
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - James Polans
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Brenton Keller
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Du Tran-Viet
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| | - Lejla Vajzovic
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| | - Anthony N. Kuo
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| | - Cynthia A. Toth
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| | - Joseph A. Izatt
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| | - Sina Farsiu
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| |
Collapse
|
11
|
Damodaran M, Amelink A, de Boer JF. Optimal wavelengths for subdiffuse scanning laser oximetry of the human retina. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-15. [PMID: 30152203 DOI: 10.1117/1.jbo.23.8.086003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Accepted: 08/02/2018] [Indexed: 06/08/2023]
Abstract
Retinal blood vessel oxygenation is considered to be an important marker for numerous eye diseases. Oxygenation is typically assessed by imaging the retinal vessels at different wavelengths using multispectral imaging techniques, where the choice of wavelengths will affect the achievable measurement accuracy. Here, we present a detailed analysis of the error propagation of measurement noise in retinal oximetry, to identify optimal wavelengths that will yield the lowest uncertainty in saturation estimation for a given measurement noise level. In our analysis, we also investigate the effect of hemoglobin packing in discrete blood vessels (pigment packaging), which may result in a nonnegligible bias in saturation estimation if unaccounted for under specific geometrical conditions, such as subdiffuse sampling of smaller blood vessels located deeper within the retina. Our analyses show that using 470, 506, and 592 nm, a fairly accurate estimation of the whole oxygen saturation regime [0 1] can be realized, even in the presence of the pigment packing effect. To validate the analysis, we developed a scanning laser ophthalmoscope to produce high contrast images with a maximum pixel rate of 60 kHz and a maximum 30-deg imaging field of view. Confocal reflectance measurements were then conducted on a tissue-mimicking scattering phantom with optical properties similar to retinal tissue including narrow channels filled with absorbing dyes to mimic blood vessels. By imaging at three optimal wavelengths, the saturation of the dye combination was calculated. The experimental values show good agreement with our theoretical derivations.
Collapse
Affiliation(s)
- Mathi Damodaran
- Vrije Universiteit Amsterdam, LaserLaB, Department of Physics and Astronomy, Amsterdam, The Netherlands
| | - Arjen Amelink
- Netherlands Organisation for Applied Scientific Research TNO, Department of Optics, Delft, The Netherlands
| | - Johannes F de Boer
- Vrije Universiteit Amsterdam, LaserLaB, Department of Physics and Astronomy, Amsterdam, The Netherlands
| |
Collapse
|
12
|
Song W, Zhou L, Zhang S, Ness S, Desai M, Yi J. Fiber-based visible and near infrared optical coherence tomography (vnOCT) enables quantitative elastic light scattering spectroscopy in human retina. BIOMEDICAL OPTICS EXPRESS 2018; 9:3464-3480. [PMID: 29984110 PMCID: PMC6033571 DOI: 10.1364/boe.9.003464] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 06/09/2018] [Accepted: 06/21/2018] [Indexed: 05/18/2023]
Abstract
Elastic light scattering spectroscopy (ELSS) has been proven a powerful method in measuring tissue structures with exquisite nanoscale sensitivity. However, ELSS contrast in the living human retina has been relatively underexplored, primarily due to the lack of imaging tools with a large spectral bandwidth. Here, we report a simple all fiber-based setup to implement dual-channel visible and near infrared (NIR) optical coherence tomography (vnOCT) for human retinal imaging, bridging over a 300nm spectral gap. Remarkably, the fiber components in our vnOCT system support single-mode propagation for both visible and NIR light, both of which maintain excellent interference efficiencies with fringe visibility of 97% and 90%, respectively. The longitudinal chromatic aberration from the eye is corrected by a custom-designed achromatizing lens. The elegant fiber-based design enables simultaneous imaging for both channels and allows comprehensive ELSS analysis on several important anatomical layers, including nerve fiber layer, outer segment of the photoreceptors and retinal pigment epithelium. This vnOCT platform and method of ELSS analysis open new opportunities in understanding structure-function relationship in the human retina and in exploring new biomarkers for retinal diseases.
Collapse
Affiliation(s)
- Weiye Song
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Libo Zhou
- College of Electronic Science and Engineering, Jilin University, Changchun, Jilin, 130012, China
| | - Sui Zhang
- Danna-Farber Cancer Institute, Boston, MA 02215, USA
| | - Steven Ness
- Department of Ophthalmology, Boston Medical Center, Boston University School of Medicine, Boston, MA 02118, USA
| | - Manishi Desai
- Department of Ophthalmology, Boston Medical Center, Boston University School of Medicine, Boston, MA 02118, USA
| | - Ji Yi
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
- Department of Biomedical Engineering, Boston University, Boston, MA 02118, USA
| |
Collapse
|
13
|
Li H, Liu W, Dong B, Kaluzny JV, Fawzi AA, Zhang HF. Snapshot hyperspectral retinal imaging using compact spectral resolving detector array. JOURNAL OF BIOPHOTONICS 2017; 10:830-839. [PMID: 27434875 PMCID: PMC5063234 DOI: 10.1002/jbio.201600053] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 05/17/2016] [Accepted: 06/14/2016] [Indexed: 05/07/2023]
Abstract
Hyperspectral retinal imaging captures the light spectrum from each imaging pixel. It provides spectrally encoded retinal physiological and morphological information, which could potentially benefit diagnosis and therapeutic monitoring of retinal diseases. The key challenges in hyperspectral retinal imaging are how to achieve snapshot imaging to avoid motions between the images from multiple spectral bands, and how to design a compact snapshot imager suitable for clinical use. Here, we developed a compact, snapshot hyperspectral fundus camera for rodents using a novel spectral resolving detector array (SRDA), on which a thin-film Fabry-Perot cavity filter was monolithically fabricated on each imaging pixel. We achieved hyperspectral retinal imaging with 16 wavelength bands (460 to 630 nm) at 20 fps. We also demonstrated false-color vessel contrast enhancement and retinal oxygen saturation (sO2 ) measurement through spectral analysis. This work could potentially bring hyperspectral retinal imaging from bench to bedside.
Collapse
Affiliation(s)
- Hao Li
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Wenzhong Liu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Biqin Dong
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Joel V. Kaluzny
- Department of Ophthalmology, Northwestern University, Chicago, IL 60611, USA
| | - Amani A. Fawzi
- Department of Ophthalmology, Northwestern University, Chicago, IL 60611, USA
- Corresponding authors: ;
| | - Hao F. Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Ophthalmology, Northwestern University, Chicago, IL 60611, USA
- Corresponding authors: ;
| |
Collapse
|
14
|
Yang J, Liu L, Campbell JP, Huang D, Liu G. Handheld optical coherence tomography angiography. BIOMEDICAL OPTICS EXPRESS 2017; 8:2287-2300. [PMID: 28736672 PMCID: PMC5516829 DOI: 10.1364/boe.8.002287] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Revised: 02/25/2017] [Accepted: 03/12/2017] [Indexed: 05/03/2023]
Abstract
We developed a handheld optical coherence tomography angiography (OCTA) system using a 100-kHz swept-source laser. The handheld probe weighs 0.4 kg and measures 20.6 × 12.8 × 4.6 cm3. The system has dedicated features for handheld operation. The probe is equipped with a mini iris camera for easy alignment. Real-time display of the en face OCT and cross-sectional OCT images in the system allows accurately locating the imaging target. Fast automatic focusing was achieved by an electrically tunable lens controlled by a golden-section search algorithm. An extended axial imaging range of 6 mm allows easy alignment. A registration algorithm using cross-correlation to register adjacent OCT B-frames with propagation from the central frame was used to effectively minimize motion artifacts in volumetric OCTA images captured in relatively short durations of 1 and 2.1 seconds. 2.5 × 2.5 mm (200 × 200 pixels) and 3.5 × 3.5 mm (300 × 300 pixels) retinal angiograms were demonstrated on two awake adult human subjects without the use of any mydriatic eye drops.
Collapse
|
15
|
Wijesinghe RE, Lee SY, Ravichandran NK, Han S, Jeong H, Han Y, Jung HY, Kim P, Jeon M, Kim J. Optical coherence tomography-integrated, wearable (backpack-type), compact diagnostic imaging modality for in situ leaf quality assessment. APPLIED OPTICS 2017; 56:D108-D114. [PMID: 28375377 DOI: 10.1364/ao.56.00d108] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We developed a compact, wearable diagnostic imaging modality employing optical coherence tomography for in situ plant leaf quality assessments. This system is capable of diagnosing infected leaves at the initial disease stages. Our system is a versatile backpack-type imaging modality with a compact spectrometer, miniature computer, rechargeable power source, and handheld inspection probe. This method enhances real-time in situ specimen inspection through direct implementation of the imaging modality in a plantation. To evaluate the initial performance, field experiments were conducted in apple, pear, and persimmon plantations. Based on the obtained results, we can conclude that the developed imaging modality can be considered as a promising, efficient, convenient, and fast in situ inspection technique for various agricultural fields, which minimizes the limitations of complex tabletop inspection modalities.
Collapse
|
16
|
Galvin J, Tran T, Rososinski A, Fung AT. Artefactual colour with confocal scanning laser ophthalmoscopy may lead to misdiagnosis. Clin Exp Ophthalmol 2016; 44:855-856. [DOI: 10.1111/ceo.12792] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 06/04/2016] [Accepted: 06/07/2016] [Indexed: 12/01/2022]
Affiliation(s)
| | - Tuan Tran
- Sydney Hospital; Sydney Eye Hospital; Sydney Australia
| | | | - Adrian T Fung
- Faculty of Medicine and Health Sciences; Macquarie University; Sydney New South Wales Australia
- Save Sight Institute; Sydney Eye Hospital, University of Sydney; Sydney New South Wales Australia
| |
Collapse
|
17
|
Yung M, Klufas MA, Sarraf D. Clinical applications of fundus autofluorescence in retinal disease. Int J Retina Vitreous 2016; 2:12. [PMID: 27847630 PMCID: PMC5088473 DOI: 10.1186/s40942-016-0035-x] [Citation(s) in RCA: 135] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Accepted: 02/15/2016] [Indexed: 12/30/2022] Open
Abstract
Fundus autofluorescence (FAF) is a non-invasive retinal imaging modality used in clinical practice to provide a density map of lipofuscin, the predominant ocular fluorophore, in the retinal pigment epithelium. Multiple commercially available imaging systems, including the fundus camera, the confocal scanning laser ophthalmoscope, and the ultra-widefield imaging device, are available to the clinician. Each offers unique advantages for evaluating various retinal diseases. The clinical applications of FAF continue to expand. It is now an essential tool for evaluating age related macular degeneration, macular dystrophies, retinitis pigmentosa, white dot syndromes, retinal drug toxicities, and various other retinal disorders. FAF may detect abnormalities beyond those detected on funduscopic exam, fluorescein angiography, or optical coherence tomography, and can be used to elucidate disease pathogenesis, form genotype-phenotype correlations, diagnose and monitor disease, and evaluate novel therapies. Given its ease of use, non-invasive nature, and value in characterizing retinal disease, FAF enjoys increasing clinical relevance. This review summarizes common ocular fluorophores, imaging modalities, and FAF findings for a wide spectrum of retinal disorders.
Collapse
Affiliation(s)
- Madeline Yung
- Stein Eye Institute, David Geffen School of Medicine at University of California, Los Angeles, CA 90095 USA
| | - Michael A. Klufas
- Stein Eye Institute, David Geffen School of Medicine at University of California, Los Angeles, CA 90095 USA
| | - David Sarraf
- Stein Eye Institute, David Geffen School of Medicine at University of California, Los Angeles, CA 90095 USA
- Greater Los Angeles VA Healthcare Center, Los Angeles, CA 90024 USA
| |
Collapse
|
18
|
LaRocca F, Nankivil D, DuBose T, Toth CA, Farsiu S, Izatt JA. In vivo cellular-resolution retinal imaging in infants and children using an ultracompact handheld probe. NATURE PHOTONICS 2016; 10:580-584. [PMID: 29479373 PMCID: PMC5822731 DOI: 10.1038/nphoton.2016.141] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Accepted: 06/20/2016] [Indexed: 05/20/2023]
Affiliation(s)
- Francesco LaRocca
- Department of Biomedical Engineering and Fitzpatrick Institute of Photonics, Duke University, Durham, North Carolina 27708, USA
| | - Derek Nankivil
- Department of Biomedical Engineering and Fitzpatrick Institute of Photonics, Duke University, Durham, North Carolina 27708, USA
| | - Theodore DuBose
- Department of Biomedical Engineering and Fitzpatrick Institute of Photonics, Duke University, Durham, North Carolina 27708, USA
| | - Cynthia A. Toth
- Department of Biomedical Engineering and Fitzpatrick Institute of Photonics, Duke University, Durham, North Carolina 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina 27710, USA
| | - Sina Farsiu
- Department of Biomedical Engineering and Fitzpatrick Institute of Photonics, Duke University, Durham, North Carolina 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina 27710, USA
| | - Joseph A. Izatt
- Department of Biomedical Engineering and Fitzpatrick Institute of Photonics, Duke University, Durham, North Carolina 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina 27710, USA
| |
Collapse
|
19
|
|
20
|
Nankivil D, Waterman G, LaRocca F, Keller B, Kuo AN, Izatt JA. Handheld, rapidly switchable, anterior/posterior segment swept source optical coherence tomography probe. BIOMEDICAL OPTICS EXPRESS 2015; 6:4516-28. [PMID: 26601014 PMCID: PMC4646558 DOI: 10.1364/boe.6.004516] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Revised: 10/15/2015] [Accepted: 10/16/2015] [Indexed: 05/20/2023]
Abstract
We describe the first handheld, swept source optical coherence tomography (SSOCT) system capable of imaging both the anterior and posterior segments of the eye in rapid succession. A single 2D microelectromechanical systems (MEMS) scanner was utilized for both imaging modes, and the optical paths for each imaging mode were optimized for their respective application using a combination of commercial and custom optics. The system has a working distance of 26.1 mm and a measured axial resolution of 8 μm (in air). In posterior segment mode, the design has a lateral resolution of 9 μm, 7.4 mm imaging depth range (in air), 4.9 mm 6dB fall-off range (in air), and peak sensitivity of 103 dB over a 22° field of view (FOV). In anterior segment mode, the design has a lateral resolution of 24 μm, imaging depth range of 7.4 mm (in air), 6dB fall-off range of 4.5 mm (in air), depth-of-focus of 3.6 mm, and a peak sensitivity of 99 dB over a 17.5 mm FOV. In addition, the probe includes a wide-field iris imaging system to simplify alignment. A fold mirror assembly actuated by a bi-stable rotary solenoid was used to switch between anterior and posterior segment imaging modes, and a miniature motorized translation stage was used to adjust the objective lens position to correct for patient refraction between -12.6 and + 9.9 D. The entire probe weighs less than 630 g with a form factor of 20.3 x 9.5 x 8.8 cm. Healthy volunteers were imaged to illustrate imaging performance.
Collapse
Affiliation(s)
- Derek Nankivil
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Gar Waterman
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Francesco LaRocca
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Brenton Keller
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Anthony N. Kuo
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| | - Joseph A. Izatt
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, 27710, USA
| |
Collapse
|