Full-range depth-encoded swept source polarization sensitive optical coherence tomography. OPTICS EXPRESS 2024; 32:9374-9383. [PMID: 38571173 DOI: 10.1364/oe.510970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 02/09/2024] [Indexed: 04/05/2024]
Abstract
To realize the high sensitivity polarization sensitive optical coherence tomography (PS-OCT) imaging, a fiber-based full-range depth-encoded swept source PS-OCT (SS-PS-OCT) method is proposed. The two OCT images corresponding to the orthogonal polarized input light are located on the high sensitivity imaging region of the opposite sides relative to the zero optical path difference position. The full-range OCT images can be obtained by implementing the spatial phase modulation in the reference arm. The detection sensitivity of the system was measured experimentally to be 67 dB when the imaging depth approaching to 2 mm. The imaging of the biological tissue verifies that the proposed full-range depth-encoded SS-PS-OCT system has the higher detection sensitivity compared with the conventional depth encoded SS-PS-OCT system. Finally, we demonstrated the full-range high sensitivity phase retardation image of the bovine tendon and skin of human fingertip. The fiber-based full-range depth-encoded SS-PS-OCT method can realize the high sensitivity birefringence imaging in the medical diagnosis scenes with the requirements for long imaging range and high detection sensitivity.
Collapse
|
2
|
Tutorial on compressed ultrafast photography. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11524. [PMID: 38292055 PMCID: PMC10826888 DOI: 10.1117/1.jbo.29.s1.s11524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/23/2023] [Accepted: 12/28/2023] [Indexed: 02/01/2024]
Abstract
Significance Compressed ultrafast photography (CUP) is currently the world's fastest single-shot imaging technique. Through the integration of compressed sensing and streak imaging, CUP can capture a transient event in a single camera exposure with imaging speeds from thousands to trillions of frames per second, at micrometer-level spatial resolutions, and in broad sensing spectral ranges. Aim This tutorial aims to provide a comprehensive review of CUP in its fundamental methods, system implementations, biomedical applications, and prospect. Approach A step-by-step guideline to CUP's forward model and representative image reconstruction algorithms is presented with sample codes and illustrations in Matlab and Python. Then, CUP's hardware implementation is described with a focus on the representative techniques, advantages, and limitations of the three key components-the spatial encoder, the temporal shearing unit, and the two-dimensional sensor. Furthermore, four representative biomedical applications enabled by CUP are discussed, followed by the prospect of CUP's technical advancement. Conclusions CUP has emerged as a state-of-the-art ultrafast imaging technology. Its advanced imaging ability and versatility contribute to unprecedented observations and new applications in biomedicine. CUP holds great promise in improving technical specifications and facilitating the investigation of biomedical processes.
Collapse
|
3
|
Characterization of radiofrequency ablated myocardium with optical coherence tomography. Photodiagnosis Photodyn Ther 2022; 40:103151. [PMID: 36228980 DOI: 10.1016/j.pdpdt.2022.103151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 10/05/2022] [Accepted: 10/07/2022] [Indexed: 11/07/2022]
Abstract
Certain types of cardiac arrhythmias are best treated with radiofrequency (RF) ablation, in which an electrode is inserted into the targeted area of the myocardium and then RF electrical current is applied to heat and destroy surrounding tissue. The resulting ablation lesion usually consists of a coagulative necrotic core surrounded by a rim region of mixed viable and non-viable cells. The characterization of the RF ablated lesion is of potential clinical importance. Here we aim to elaborate optical coherence tomography (OCT) imaging for the characterization of RF-ablated myocardial tissue. In particular, the underlying principles of OCT and its polarization-sensitive counterpart (PS-OCT) are presented, followed by the knowledge needed to interpret their optical images. Studies focused on real-time monitoring of RF lesion formation in the myocardium using OCT systems are summarized. The design and development of various hybrid probes incorporating both OCT guidance and RF ablation catheters are also discussed. Finally, the challenges related to the transmission of OCT imaging systems to cardiac clinics for real-time monitoring of RF lesions are outlined.
Collapse
|
4
|
Two concepts for ultra-high-resolution polarization-sensitive optical coherence tomography with a single camera. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2022; 39:1295-1308. [PMID: 36215616 DOI: 10.1364/josaa.458631] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 06/12/2022] [Indexed: 06/16/2023]
Abstract
Two designs with a multiplexed superluminescent diode for ultra-high-resolution spectral-domain polarization-sensitive optical coherence tomography (UHR-PS-OCT) are introduced. In the first design, a Wollaston prism separates orthogonal polarization states next to each other on one linescan camera; the other design uses a beam displacer to separate orthogonal states onto two lines of a linescan camera with multiple rows of detectors. The coherence lengths measured with the two systems were 3.6 µm and 2.9 µm (n=1.38), respectively. Measurements were collected from the fovea of a healthy subject, a healthy subject with astigmatism, and a patient with central serous retinopathy (CSR). A single volumetric scan provides double pass retardance induced by the retinal nerve fiber layer birefringence (RNFL) and its birefringence, the cumulative double pass retardance induced by the Henle fiber layer, and the retardance that is induced by the retinal pigment epithelium-Bruch's membrane complex. The high axial resolution in UHR-PS-OCT is particularly helpful for the measurements of thin retinal tissue, such as the RNFL in the fovea, where birefringence values of around 1°/µm were found. Tilting of the retina due to a CSR or by off centering the imaging beam in the pupil causes an artificial increase in the double pass retardance induced by the RNFL and Henle fiber layer.
Collapse
|
5
|
Analysis and reduction of noise-induced depolarization in catheter based polarization sensitive optical coherence tomography. OPTICS EXPRESS 2022; 30:11130-11149. [PMID: 35473063 DOI: 10.1364/oe.453116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 03/08/2022] [Indexed: 06/14/2023]
Abstract
In catheter based polarization sensitive optical coherence tomography (PS-OCT), a optical fiber with a rapid rotation in the catheter can cause low signal-to-noise ratio (SNR), polarization state instability, phase change of PS-OCT signals and then heavy noise-induced depolarization, which has a strong impact on the phase retardation measurement of the sample. In this paper, we analyze the noise-induced depolarization and find that the effect of depolarization can be reduced by polar decomposition after incoherent averaging in the Mueller matrix averaging (MMA) method. Namely, MMA can reduce impact of noise on phase retardation mapping. We present a Monte Carlo method based on PS-OCT to numerically describe noise-induced depolarization effect and contrast phase retardation imaging results by MMA and Jones matrix averaging (JMA) methods. The peak signal to noise ratio (PSNR) of simulated images processed by MMA is higher than about 8.9 dB than that processed by JMA. We also implement experiments of multiple biological tissues using the catheter based PS-OCT system. From the simulation and experimental results, we find the polarization contrasts processed by the MMA are better than those by JMA, especially at areas with high depolarization, because the MMA can reduce effect of noise-induced depolarization on the phase retardation measurement.
Collapse
|
6
|
Excess comorbidities in gout: the causal paradigm and pleiotropic approaches to care. Nat Rev Rheumatol 2022; 18:97-111. [PMID: 34921301 DOI: 10.1038/s41584-021-00725-9] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/18/2021] [Indexed: 02/07/2023]
Abstract
Gout is a common hyperuricaemic metabolic condition that leads to painful inflammatory arthritis and a high comorbidity burden, especially cardiometabolic-renal (CMR) conditions, including hypertension, myocardial infarction, stroke, obesity, hyperlipidaemia, type 2 diabetes mellitus and chronic kidney disease. Substantial advances have been made in our understanding of the excess CMR burden in gout, ranging from pathogenesis underlying excess CMR comorbidities, inferring causal relationships from Mendelian randomization studies, and potentially discovering urate crystals in coronary arteries using advanced imaging, to clinical trials and observational studies. Despite many studies finding an independent association between blood urate levels and risk of incident CMR events, Mendelian randomization studies have largely found that serum urate is not causal for CMR end points or intermediate risk factors or outcomes (such as kidney function, adiposity, metabolic syndrome, glycaemic traits or blood lipid concentrations). Although limited, randomized controlled trials to date in adults without gout support this conclusion. If imaging studies suggesting that monosodium urate crystals are deposited in coronary plaques in patients with gout are confirmed, it is possible that these crystals might have a role in the inflammatory pathogenesis of increased cardiovascular risk in patients with gout; removing monosodium urate crystals or blocking the inflammatory pathway could reduce this excess risk. Accordingly, data for CMR outcomes with these urate-lowering or anti-inflammatory therapies in patients with gout are needed. In the meantime, highly pleiotropic CMR and urate-lowering benefits of sodium-glucose cotransporter 2 (SGLT2) inhibitors and key lifestyle measures could play an important role in comorbidity care, in conjunction with effective gout care based on target serum urate concentrations according to the latest guidelines.
Collapse
|
7
|
Abstract
Optical coherence tomography (OCT) is a non-contact method for imaging the topological and internal microstructure of samples in three dimensions. OCT can be configured as a conventional microscope, as an ophthalmic scanner, or using endoscopes and small diameter catheters for accessing internal biological organs. In this Primer, we describe the principles underpinning the different instrument configurations that are tailored to distinct imaging applications and explain the origin of signal, based on light scattering and propagation. Although OCT has been used for imaging inanimate objects, we focus our discussion on biological and medical imaging. We examine the signal processing methods and algorithms that make OCT exquisitely sensitive to reflections as weak as just a few photons and that reveal functional information in addition to structure. Image processing, display and interpretation, which are all critical for effective biomedical imaging, are discussed in the context of specific applications. Finally, we consider image artifacts and limitations that commonly arise and reflect on future advances and opportunities.
Collapse
|
8
|
Polarization sensitive optical coherence tomography with single input for imaging depth-resolved collagen organizations. LIGHT, SCIENCE & APPLICATIONS 2021; 10:237. [PMID: 34819490 PMCID: PMC8613400 DOI: 10.1038/s41377-021-00679-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 10/26/2021] [Accepted: 11/10/2021] [Indexed: 05/02/2023]
Abstract
Collagen organization plays an important role in maintaining structural integrity and determining tissue function. Polarization-sensitive optical coherence tomography (PSOCT) is a promising noninvasive three-dimensional imaging tool for mapping collagen organization in vivo. While PSOCT systems with multiple polarization inputs have demonstrated the ability to visualize depth-resolved collagen organization, systems, which use a single input polarization state have not yet demonstrated sufficient reconstruction quality. Herein we describe a PSOCT based polarization state transmission model that reveals the depth-dependent polarization state evolution of light backscattered within a birefringent sample. Based on this model, we propose a polarization state tracing method that relies on a discrete differential geometric analysis of the evolution of the polarization state in depth along the Poincare sphere for depth-resolved birefringent imaging using only one single input polarization state. We demonstrate the ability of this method to visualize depth-resolved myocardial architecture in both healthy and infarcted rodent hearts (ex vivo) and collagen structures responsible for skin tension lines at various anatomical locations on the face of a healthy human volunteer (in vivo).
Collapse
|
9
|
Ultimate Spatial Resolution Realisation in Optical Frequency Domain Reflectometry with Equal Frequency Resampling. SENSORS 2021; 21:s21144632. [PMID: 34300374 PMCID: PMC8309478 DOI: 10.3390/s21144632] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 06/28/2021] [Accepted: 06/29/2021] [Indexed: 11/17/2022]
Abstract
A method based on equal frequency resampling is proposed to suppress laser nonlinear frequency sweeping for the ultimate spatial resolution in optical frequency domain reflectometry. Estimation inaccuracy of the sweeping frequency distribution caused by the finite sampling rate in the auxiliary interferometer can be efficiently compensated by the equal frequency resampling method. With the sweeping range of 130 nm, a 12.1 µm spatial resolution is experimentally obtained. In addition, the sampling limitation of the auxiliary interferometer-based correction is discussed. With a 200 m optical path delay in the auxiliary interferometer, a 21.3 µm spatial resolution is realised at the 191 m fibre end. By employing the proposed resampling and a drawing tower FBG array to enhance the Rayleigh backscattering, a distributed temperature sensing over a 105 m fibre with a sensing resolution of 1 cm is achieved. The measured temperature uncertainty is limited to ±0.15 °C.
Collapse
|
10
|
Using image data to numerically correct the jitter in polarization depth encoding PS-OCT. OPTICS LETTERS 2021; 46:1692-1695. [PMID: 33793520 DOI: 10.1364/ol.420029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 03/06/2021] [Indexed: 06/12/2023]
Abstract
In swept source polarization depth encoding polarization sensitive optical coherence tomography (PS-OCT), the laser jitter induces additional noise to the polarization sensitive measurement. In this Letter, we developed a numerical algorithm to correct the jitter phases based on the image data using the Mueller matrix calculus. The algorithm was demonstrated on in vivo retina imaging of a guinea pig with a custom-built PS-OCT system. The performance of the proposed algorithm was almost comparable to the conventional method of using a physical calibration signal. By not requiring a hardware generated calibration signal and k-clock, the proposed algorithm is useful to reduce the complexity and the cost of a polarization depth encoding PS-OCT system.
Collapse
|
11
|
Punching holes in light: recent progress in single-shot coded-aperture optical imaging. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2020; 83:116101. [PMID: 33125347 DOI: 10.1088/1361-6633/abaf43] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Single-shot coded-aperture optical imaging physically captures a code-aperture-modulated optical signal in one exposure and then recovers the scene via computational image reconstruction. Recent years have witnessed dazzling advances in various modalities in this hybrid imaging scheme in concomitant technical improvement and widespread applications in physical, chemical and biological sciences. This review comprehensively surveys state-of-the-art single-shot coded-aperture optical imaging. Based on the detected photon tags, this field is divided into six categories: planar imaging, depth imaging, light-field imaging, temporal imaging, spectral imaging, and polarization imaging. In each category, we start with a general description of the available techniques and design principles, then provide two representative examples of active-encoding and passive-encoding approaches, with a particular emphasis on their methodology and applications as well as their advantages and challenges. Finally, we envision prospects for further technical advancement in this field.
Collapse
|
12
|
High-resolution polarization-sensitive optical coherence tomography for zebrafish muscle imaging. BIOMEDICAL OPTICS EXPRESS 2020; 11:5618-5632. [PMID: 33149975 PMCID: PMC7587288 DOI: 10.1364/boe.402267] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/18/2020] [Accepted: 09/07/2020] [Indexed: 05/20/2023]
Abstract
Zebrafish are an important animal model, whose structure and function information can be used to study development, pathologic changes and genetic mutations. However, limited by the penetration depth, the available optical methods are difficult to image the whole-body zebrafish in juvenile and adult stages. Based on a home-made high-resolution polarization-sensitive optical coherence tomography (PS-OCT) system, we finished in vivo volumetric imaging for zebrafish, and various muscles can be clearly discerned by scanning from dorsal, ventral, and lateral directions. Besides structure information, polarization properties extracted from PS-OCT images provide abundant function information to distinguish different muscles. Furthermore, we found local retardation and local optic axis of zebrafish muscle are related to their composition and fiber orientation. We think high-resolution PS-OCT will be a promising tool in studying myopathy models of zebrafish.
Collapse
|
13
|
Distinguishing Tumor from Associated Fibrosis to Increase Diagnostic Biopsy Yield with Polarization-Sensitive Optical Coherence Tomography. Clin Cancer Res 2019; 25:5242-5249. [PMID: 31175092 DOI: 10.1158/1078-0432.ccr-19-0566] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 04/09/2019] [Accepted: 06/03/2019] [Indexed: 12/20/2022]
Abstract
PURPOSE With recent advancements in personalized medicine, biopsies must contain sufficient tumor for histologic diagnosis and molecular testing. However, inadvertent biopsy of tumor-associated fibrosis compromises tumor yield, resulting in delayed diagnoses and/or repeat procedures when additional tumor is needed. The ability to differentiate tumor from fibrosis intraprocedurally during biopsy could significantly increase tumor yield. Polarization-sensitive optical coherence tomography (PS-OCT) is an imaging modality that is endoscope- and/or needle-compatible, and provides large volumetric views of tissue microstructure with high resolution (∼10 μm) while simultaneously measuring birefringence of organized tissues such as collagen. We aim to determine whether PS-OCT can accurately detect and distinguish tumor-associated fibrosis from tumor. EXPERIMENTAL DESIGN PS-OCT was obtained ex vivo in 64 lung nodule samples. PS-OCT birefringence was measured and correlated to collagen content in precisely matched histology, quantified on picrosirius red (PSR) staining. RESULTS There was a strong positive correlation between PS-OCT measurement of birefringent fibrosis and total collagen content by PSR (r = 0.793; P < 0.001). In addition, PS-OCT was able to accurately classify tumor regions with >20% fibrosis from those with low fibrosis (≤20%) that would likely yield higher tumor content (P < 0.0001). CONCLUSIONS PS-OCT enables accurate fibrosis detection and can distinguish tumor regions with low fibrosis. PS-OCT has significant potential for clinical impact, as the ability to differentiate tumor from fibrosis could be used to guide intraprocedural tissue sampling in vivo, or for rapid biopsy adequacy assessment ex vivo, to increase diagnostic tumor yield essential for patient care and research.
Collapse
|
14
|
Parallel detection of Jones-matrix elements in polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2019; 10:2318-2336. [PMID: 31149375 PMCID: PMC6524579 DOI: 10.1364/boe.10.002318] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/16/2019] [Accepted: 03/18/2019] [Indexed: 06/09/2023]
Abstract
The polarization properties of a sample can be characterized using a Jones matrix. To measure the Jones matrix without assumptions of the sample, two different incident states of polarization are usually used. This requirement often causes certain drawbacks in polarization-sensitive optical coherence tomography (PS-OCT), e.g., a decrease in the effective A-scan rate or axial depth range, if a multiplexing scheme is used. Because both the A-scan rate and axial depth range are important for clinical applications, including the imaging of an anterior eye segment, a new PS-OCT method that does not have these drawbacks is desired. Here, we present a parallel-detection approach that maintains the same A-scan rate and axial measurement range as conventional OCT. The interferometer consists of fiber-optic components, most of which are polarization-maintaining components with fast-axis blocking free from polarization management. When a parallel detection is implemented using swept-source OCT (SS-OCT), synchronization between the A-scans and synchronization between the detection channels have critical effects on the Jones-matrix measurement. Because it is difficult to achieve perfect synchronization using only hardware, we developed a solution using a numerical correction with signals from a static mirror. Using the developed system, we demonstrate the imaging of an anterior eye segment from the cornea to the back surface of the crystalline lens.
Collapse
|
15
|
Catheter-Based Polarization Sensitive Optical Coherence Tomography Using Similar Mueller Matrix Method. IEEE Trans Biomed Eng 2019; 67:60-68. [PMID: 30932827 DOI: 10.1109/tbme.2019.2908031] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Research of catheter-based polarization sensitive optical coherence tomography (PS-OCT) is a challenging field. In this paper, we present a new polarization determination method, similar Mueller matrix (SMM) method, for a catheter-based PS-OCT system using a standard clinical catheter probe with an outer diameter of 0.9 mm. METHODS The SMM method can remove the diattenuation and depolarization compositions by polar decomposition. By constructing the similarity between the measured Mueller matrices and sample matrices, the phase retardance of the sample can be determined from the trace of the measured matrices. RESULTS In the experiments, we find that images processed by the SMM method without any averaging or phase correction have a better polarization contrast of multiple biological tissues than those by the Jones matrix based method. We also preliminarily achieve phase retardance imaging of the ex vivo porcine cardiac blood vessel. CONCLUSION Compared with the Jones matrix based method, the presented SMM method can provide a more robust birefringence imaging of biological tissues under low signal-to-noise ratio, depolarization, diattenuation, and phase instability. SIGNIFICANCE The SMM method has a potential to become a widely accepted polarization determination method for catheter-based PS-OCT.
Collapse
|
16
|
Depolarization characteristics of spatial modes in imaging probe using short multimode fiber. APPLIED OPTICS 2018; 57:10083-10091. [PMID: 30645212 DOI: 10.1364/ao.57.010083] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Accepted: 10/29/2018] [Indexed: 06/09/2023]
Abstract
Optical coherence tomography is one of the standard imaging modalities at present, widely used in the medical and biological fields to obtain three-dimensional (3D) images with high spatial resolution. However, the depth up to which the 3D images can be directly obtained is limited to within 3 mm. Therefore, the suitability of many kinds of catheters and needles has been considered for minimally invasive imaging. We have examined the utility of a short multimode fiber (SMMF) using graded index optical fibers for minimal invasive imaging of deeper areas, up to 6-8 mm. The diameter and length of the SMMF are 125 μm and 6-8 mm, respectively. In the core of the SMMF, scattering and multirefraction occur due to small variations in the refractive index to generate deformations and depolarization of images. In order to investigate the depolarization characteristics, the images reflected at the facet of the SMMF were measured by changing the angle of the polarizer, using an LED as the light source. The reflection image almost corresponds to that obtained with combined linearly polarized modes with the ratio of LP01∶LP11∶LP21 equal to 1∶0.2∶0.7. Comparing the measured results with simulations in the simple model, the depolarization ratio was estimated at 0.7 in the core. The degrees of polarization were measured to be 0.15 around the center and increased to 0.90 at the periphery.
Collapse
|
17
|
Clinical prototype of pigment and flow imaging optical coherence tomography for posterior eye investigation. BIOMEDICAL OPTICS EXPRESS 2018; 9:4372-4389. [PMID: 30615718 PMCID: PMC6157782 DOI: 10.1364/boe.9.004372] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 08/10/2018] [Accepted: 08/10/2018] [Indexed: 05/18/2023]
Abstract
Measurements of the randomness of polarization (RP) obtained using polarization-sensitive optical coherence tomography (PS-OCT) are applied in several applications, and RP is attractive for posterior eye imaging. The addition of RP without retardation requires a minimal extension to standard OCT; therefore, we developed a prototype OCT system with a simplified scheme for RP measurement. A compact polarization-diversity receiver module is the only required hardware extension to a standard OCT system. All components were packed into the retinal scanning head. The degree-of-polarization uniformity and complex-decorrelation based OCT angiography were calculated using noise-corrected algorithms that accounted for the depth-dependent noise power. The structure, melanin, and blood flow distribution imaging of in vivo human eyes were demonstrated. Pathological eye imaging shows potential applications for combinations of these contrasts.
Collapse
|
18
|
Ultra low noise Fourier domain mode locked laser for high quality megahertz optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2018; 9:4130-4148. [PMID: 30615700 PMCID: PMC6157755 DOI: 10.1364/boe.9.004130] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 07/16/2018] [Accepted: 07/16/2018] [Indexed: 05/28/2023]
Abstract
We investigate the origin of high frequency noise in Fourier domain mode locked (FDML) lasers and present an extremely well dispersion compensated setup which virtually eliminates intensity noise and dramatically improves coherence properties. We show optical coherence tomography (OCT) imaging at 3.2 MHz A-scan rate and demonstrate the positive impact of the described improvements on the image quality. Especially in highly scattering samples, at specular reflections and for strong signals at large depth, the noise in optical coherence tomography images is significantly reduced. We also describe a simple model that suggests a passive physical stabilizing mechanism that leads to an automatic compensation of remaining cavity dispersion in FDML lasers.
Collapse
|
19
|
Optical coherence tomography in gastroenterology: a review and future outlook. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-17. [PMID: 29260538 DOI: 10.1117/1.jbo.22.12.121716] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 12/05/2017] [Indexed: 05/18/2023]
Abstract
Optical coherence tomography (OCT) is an imaging technique optically analogous to ultrasound that can generate depth-resolved images with micrometer-scale resolution. Advances in fiber optics and miniaturized actuation technologies allow OCT imaging of the human body and further expand OCT utilization in applications including but not limited to cardiology and gastroenterology. This review article provides an overview of current OCT development and its clinical utility in the gastrointestinal tract, including disease detection/differentiation and endoscopic therapy guidance, as well as a discussion of its future applications.
Collapse
|
20
|
|
21
|
Tissue-like phantoms for quantitative birefringence imaging. BIOMEDICAL OPTICS EXPRESS 2017; 8:4454-4465. [PMID: 29082077 PMCID: PMC5654792 DOI: 10.1364/boe.8.004454] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 08/27/2017] [Accepted: 08/29/2017] [Indexed: 05/07/2023]
Abstract
Birefringence imaging, including polarization sensitive optical coherence tomography (PS-OCT), can provide valuable insight into the microscopic structure and organization of many biological tissues. In this paper, we report on a method to fabricate tissue-like birefringence phantoms for such imaging modalities. We utilize the photo-elastic effect, wherein birefringence is induced by stretching a polymer sample after heating it above its glass-transition temperature. The cooled samples stably exhibit homogeneous birefringence, and were assembled into phantoms containing multiple well-defined regions of distinct birefringence. We present planar slab phantoms for microscopy applications and cylindrical phantoms for catheter-based imaging and demonstrate quantitative analysis of the birefringence within individual regions of interest. Birefringence phantoms enable testing, validating, calibrating, and improving PS-OCT acquisition systems and reconstruction strategies.
Collapse
|
22
|
Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7050474] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
23
|
Visualization of neuritic plaques in Alzheimer's disease by polarization-sensitive optical coherence microscopy. Sci Rep 2017; 7:43477. [PMID: 28262719 PMCID: PMC5337955 DOI: 10.1038/srep43477] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Accepted: 01/24/2017] [Indexed: 12/16/2022] Open
Abstract
One major hallmark of Alzheimer's disease (AD) and cerebral amyloid angiopathy (CAA) is the deposition of extracellular senile plaques and vessel wall deposits composed of amyloid-beta (Aβ). In AD, degeneration of neurons is preceded by the formation of Aβ plaques, which show different morphological forms. Most of them are birefringent owing to the parallel arrangement of amyloid fibrils. Here, we present polarization sensitive optical coherence microscopy (PS-OCM) for imaging mature neuritic Aβ plaques based on their birefringent properties. Formalin-fixed, post-mortem brain samples of advanced stage AD patients were investigated. In several cortical brain regions, neuritic Aβ plaques were successfully visualized in tomographic and three-dimensional (3D) images. Cortical grey matter appeared polarization preserving, whereas neuritic plaques caused increased phase retardation. Consistent with the results from PS-OCM imaging, the 3D structure of senile Aβ plaques was computationally modelled for different illumination settings and plaque sizes. Furthermore, the birefringent properties of cortical and meningeal vessel walls in CAA were investigated in selected samples. Significantly increased birefringence was found in smaller vessels. Overall, these results provide evidence that PS-OCM is able to assess amyloidosis based on intrinsic birefringent properties.
Collapse
|
24
|
Polarization sensitive optical coherence tomography - a review [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:1838-1873. [PMID: 28663869 PMCID: PMC5480584 DOI: 10.1364/boe.8.001838] [Citation(s) in RCA: 190] [Impact Index Per Article: 27.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/16/2017] [Accepted: 02/16/2017] [Indexed: 05/18/2023]
Abstract
Optical coherence tomography (OCT) is now a well-established modality for high-resolution cross-sectional and three-dimensional imaging of transparent and translucent samples and tissues. Conventional, intensity based OCT, however, does not provide a tissue-specific contrast, causing an ambiguity with image interpretation in several cases. Polarization sensitive (PS) OCT draws advantage from the fact that several materials and tissues can change the light's polarization state, adding an additional contrast channel and providing quantitative information. In this paper, we review basic and advanced methods of PS-OCT and demonstrate its use in selected biomedical applications.
Collapse
|
25
|
High resolution imaging of the fibrous microstructure in bovine common carotid artery using optical polarization tractography. JOURNAL OF BIOPHOTONICS 2017; 10:231-241. [PMID: 26663698 DOI: 10.1002/jbio.201500229] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Revised: 11/04/2015] [Accepted: 11/23/2015] [Indexed: 05/18/2023]
Abstract
The biomechanical properties of artery are primarily determined by the fibrous structures in the vessel wall. Many vascular diseases are associated with alternations in the orientation and alignment of the fibrous structure in the arterial wall. Knowledge on the structural features of the artery wall is crucial to our understanding of the biology of vascular diseases and the development of novel therapies. Optical coherence tomography (OCT) and polarization-sensitive OCT have shown great promise in imaging blood vessels due to their high resolution, fast acquisition, good imaging depth, and large field of view. However, the feasibility of using OCT based methods for imaging fiber orientation and distribution in the arterial wall has not been investigated. Here we show that the optical polarization tractography (OPT), a technology developed from Jones matrix OCT, can reveal the fiber orientation and alignment in the bovine common carotid artery. The fiber orientation and alignment data obtained in OPT provided a robust contrast marker to clearly resolve the intima and media boundary of the carotid artery wall. Optical polarization tractography can visualize fiber orientation and alignment in carotid artery.
Collapse
|
26
|
Abstract
Owing to their electromagnetic properties, tunability and biocompatibility, gold nanorods (GNRs) are being investigated as multifunctional probes for a range of biomedical applications. However, detection beyond the reach of traditional fluorescence and two-photon approaches and quantitation of their concentration in biological tissue remain challenging tasks in microscopy. Here we show how the size and aspect ratio that impart GNRs with their plasmonic properties also make them a source of entropy. We report on how depolarization can be exploited as a strategy to visualize GNR diffusion and distribution in biologically relevant scenarios ex vivo, in vitro and in vivo. We identify a deterministic relation between depolarization and nanoparticle concentration. As a result, some of the most stringent experimental conditions can be relaxed, and susceptibility to artefacts is reduced, enabling microscopic and macroscopic applications.
Collapse
|
27
|
Assessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery. J Ophthalmol 2016; 2016:4861837. [PMID: 27795855 PMCID: PMC5066020 DOI: 10.1155/2016/4861837] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Accepted: 09/01/2016] [Indexed: 12/04/2022] Open
Abstract
Purpose. To compare the changes of anterior segment parameters, assessed by swept source anterior segment optical coherence tomography (AS-OCT) after combined Trabectome-cataract surgery and Trabectome-only surgery in open angle glaucoma patients. Methods. Thirty-eight eyes of 24 patients with open angle glaucoma were scanned with swept source AS-OCT before and 4 weeks after combined Trabectome-cataract or Trabectome-only surgery. Intraocular pressure, number of medications, and AS-OCT parameters, such as angle opening distance at 500 and 750 μm from the scleral spur (AOD500 and AOD750), trabecular-iris space area at 500 and 750 mm2 (TISA500, TISA750), angle recess area at 500 and 750 mm2 (ARA500, ARA750), trabecular iris angle (TIA), anterior chamber depth (ACD), anterior chamber width (ACW), and anterior chamber volume (ACV), were obtained before the surgery. These parameters were compared to evaluate whether the outcome of the surgery differed among the patients after the surgery. The width of the trabecular cleft was also measured for both groups. Results. The reduction of IOP and number of medications was found to be statistically significant in both groups (p < 0.001). ACD, ACV, and angle parameters such as AOD 500/750, TISA 500/750, ARA 500/750, and TIA500 showed significantly greater changes from the preoperative values to postoperative 1st month values in combined Trabectome-cataract surgery group (p < 0.05), whereas Trabectome-only group did not show statistically significant difference (p > 0.05). There was no statistically significant difference between two groups for the width of the trabecular cleft (p = 0.7). Conclusion. Anterior chamber angle parameters measured with swept source AS-OCT may be useful for evaluating glaucoma patients before and after Trabectome surgery with or without cataract surgery.
Collapse
|
28
|
Development of birefringence imaging analysis method for observing cubic crystals in various phase transitions. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:073704. [PMID: 27475562 DOI: 10.1063/1.4958662] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Optical birefringence imaging systems demonstrate a high potential for comprehensively investigating various phase transitions. To completely demonstrate such abilities, the temperature dependence of birefringence (Δn) was measured in Δn ≃ 0 materials (i.e., cubic crystals with imperfect crystallization) via a background subtraction method. As a result, highly accurate birefringence imaging at 384 × 288 pixels was obtained using phase transition processes as well as varying temperatures visually characterized by the spatial distribution of not only the retardance level but also the optical fast-axis azimuth.
Collapse
|
29
|
Degree of polarization (uniformity) and depolarization index: unambiguous depolarization contrast for optical coherence tomography. OPTICS LETTERS 2015; 40:3954-7. [PMID: 26368685 PMCID: PMC4586115 DOI: 10.1364/ol.40.003954] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
The degree of polarization (uniformity) has attracted increased interest as a functional contrast in optical coherence tomography (OCT). However, its computation from a single polarization state suggests an ambiguity that is strongly dependent on a sample's orientation. We here propose an improved metric to present depolarization with respect to the optical system rather than the propagating field. Using numerical simulations and optical frequency domain imaging, we evaluate the conventional DOP(U) for different polarization states and compare its performance with the unambiguous depolarization index.
Collapse
|
30
|
Abstract
In the past decade, several functional extensions of optical coherence tomography (OCT) have emerged, and this review highlights key advances in instrumentation, theoretical analysis, signal processing and clinical application of these extensions. We review five principal extensions: Doppler OCT (DOCT), polarization-sensitive OCT (PS-OCT), optical coherence elastography (OCE), spectroscopic OCT (SOCT), and molecular imaging OCT. The former three have been further developed with studies in both ex vivo and in vivo human tissues. This review emphasizes the newer techniques of SOCT and molecular imaging OCT, which show excellent potential for clinical application but have yet to be well reviewed in the literature. SOCT elucidates tissue characteristics, such as oxygenation and carcinogenesis, by detecting wavelength-dependent absorption and scattering of light in tissues. While SOCT measures endogenous biochemical distributions, molecular imaging OCT detects exogenous molecular contrast agents. These newer advances in functional OCT broaden the potential clinical application of OCT by providing novel ways to understand tissue activity that cannot be accomplished by other current imaging methodologies.
Collapse
|
31
|
Dark-field polarization-sensitive optical coherence tomography. OPTICS EXPRESS 2015; 23:12874-86. [PMID: 26074541 DOI: 10.1364/oe.23.012874] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Polarization-sensitive optical coherence tomography (PS-OCT) is a functional OCT providing both structural and birefringent information of the sample, and it has been applied to the studies of various organs having polarization properties. Fiber-based PS-OCT is sensitive to specular reflection from the sample surface, because signal saturation due to the strong specular reflection can make the polarization measurement difficult. We developed a dark-field PS-OCT which can avoid the specular reflection problem. Dark-field PS-OCT was implemented by adapting a hybrid method of Bessel-beam illumination and Gaussian-beam detection, and a PS-OCT method based on passive delay unit (PDU). The new system was characterized in comparison with the conventional Gaussian-beam based method in both polarization components and various samples including the human skin. Dark-field PS-OCT performed as good as the conventional PS-OCT without the specular reflection artifact. Dark-field PS-OCT may be useful in practical situations where the specular reflection is unavoidable.
Collapse
|
32
|
Quantitative single-mode fiber based PS-OCT with single input polarization state using Mueller matrix. BIOMEDICAL OPTICS EXPRESS 2015; 6:1828-43. [PMID: 26137383 PMCID: PMC4467718 DOI: 10.1364/boe.6.001828] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Revised: 04/12/2015] [Accepted: 04/14/2015] [Indexed: 05/18/2023]
Abstract
We present a simple but effective method to quantitatively measure the birefringence of tissue by an all single-mode fiber (SMF) based polarization-sensitive optical coherence tomography (PS-OCT) with single input polarization state. We theoretically verify that our SMF based PS-OCT system can quantify the phase retardance and optic axis orientation after a simple calibration process using a quarter wave plate (QWP). Based on the proposed method, the quantification of the phase retardance and optic axis orientation of a Berek polarization compensator and biological tissues were demonstrated.
Collapse
|
33
|
Single input state, single-mode fiber-based polarization-sensitive optical frequency domain imaging by eigenpolarization referencing. OPTICS LETTERS 2015; 40:2025-8. [PMID: 25927775 PMCID: PMC4421894 DOI: 10.1364/ol.40.002025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Fiber-based polarization-sensitive optical frequency domain imaging is more challenging than free-space implementations. Using multiple input states, fiber-based systems provide sample birefringence information with the benefit of a flexible sample arm but come at the cost of increased system and acquisition complexity, and either reduce acquisition speed or require increased acquisition bandwidth. Here we show that with the calibration of a single polarization state, fiber-based configurations can approach the conceptual simplicity of traditional free-space configurations. We remotely control the polarization state of the light incident at the sample using the eigenpolarization states of a wave plate as a reference, and determine the Jones matrix of the output fiber. We demonstrate this method for polarization-sensitive imaging of biological samples.
Collapse
|
34
|
Multi-functional angiographic OFDI using frequency-multiplexed dual-beam illumination. OPTICS EXPRESS 2015; 23:8939-47. [PMID: 25968731 PMCID: PMC4523372 DOI: 10.1364/oe.23.008939] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Revised: 03/13/2015] [Accepted: 03/18/2015] [Indexed: 05/17/2023]
Abstract
Detection of blood flow inside the tissue sample can be achieved by measuring the local change of complex signal over time in angiographic optical coherence tomography (OCT). In conventional angiographic OCT, the transverse displacement of the imaging beam during the time interval between a pair of OCT signal measurements must be significantly reduced to minimize the noise due to the beam scanning-induced phase decorrelation at the expense of the imaging speed. Recent introduction of dual-beam scan method either using polarization encoding or two identical imaging systems in spectral-domain (SD) OCT scheme shows potential for high-sensitivity vasculature imaging without suffering from spurious phase noise caused by the beam scanning-induced spatial decorrelation. In this paper, we present multi-functional angiographic optical frequency domain imaging (OFDI) using frequency-multiplexed dual-beam illumination. This frequency multiplexing scheme, utilizing unique features of OFDI, provides spatially separated dual imaging beams occupying distinct electrical frequency bands that can be demultiplexed in the frequency domain processing. We demonstrate the 3D multi-functional imaging of the normal mouse skin in the dorsal skin fold chamber visualizing distinct layer structures from the intensity imaging, information about mechanical integrity from the polarization-sensitive imaging, and depth-resolved microvasculature from the angiographic imaging that are simultaneously acquired and automatically co-registered.
Collapse
|
35
|
Fiber-based polarization-sensitive OCT for birefringence imaging of the anterior eye segment. BIOMEDICAL OPTICS EXPRESS 2015; 6:369-89. [PMID: 25780730 PMCID: PMC4354580 DOI: 10.1364/boe.6.000369] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2014] [Revised: 12/22/2014] [Accepted: 12/23/2014] [Indexed: 05/21/2023]
Abstract
We demonstrate a prototype system of polarization-sensitive optical coherence tomography (PS-OCT) designed for clinical studies of the anterior eye segment imaging. The system can measure Jones matrices of the sample with depth-multiplexing of two orthogonal incident polarizations and polarization-sensitive detection. An optical clock is generated using a quadrature modulator and a logical circuit to double the clock frequency. Systematic artifacts in measured Jones matrices are theoretically analyzed and numerically compensated using signals at the surface of the sample. Local retardation images of filtering blebs after trabeculectomy show improved visualization of subconjunctival tissue, sclera, and scar tissue of the bleb wall in the anterior eye segment.
Collapse
|
36
|
One-step Jones matrix polarization holography for extraction of spatially resolved Jones matrix of polarization-sensitive materials. OPTICS LETTERS 2014; 39:6170-6173. [PMID: 25361306 DOI: 10.1364/ol.39.006170] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We propose, for the first time to our knowledge, a method for realizing one-step measurement of two-dimensional Jones matrix parameters of polarization-sensitive materials. This method could be called one-step Jones matrix polarization holography (JMPH). Our theoretical analysis and the experimental results demonstrate that a double-source polarization interferometer combined with angular multiplexing holography make it possible to realize one-step holographic measurements of four spatially resolved Jones matrix parameters. Compared with the existing methods, our one-step JMPH has a simpler optical arrangement and easier measuring procedure. We believe that it will provide a new approach for development of an integrated system suitable for measuring, in real-time, a Jones matrix or transmittance matrix, as well as dynamic polarization imaging.
Collapse
|
37
|
Fiber-Based Polarization Diversity Detection for Polarization-Sensitive Optical Coherence Tomography. PHOTONICS 2014. [DOI: 10.3390/photonics1040283] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
38
|
Coherent signal composition and global phase determination in signal multiplexed polarization sensitive optical coherence tomography. OPTICS EXPRESS 2014; 22:21382-92. [PMID: 25321516 DOI: 10.1364/oe.22.021382] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We present an analysis of the structural image information acquired with polarization sensitive optical coherence tomography (PS-OCT). In PS-OCT a total of four channels of data are acquired: two orthogonal polarization state components for each of two incident polarization states by which the sample is interrogated. Up to recently, the structural information of the sample was obtained by incoherent summation of these four channels. The four channels can be represented as a Jones matrix for each data point acquired from a sample. We show that the Signal to Noise ratio of the structural information can be improved by 2.3 dB by taking advantage of the structure of this Jones matrix, imposed by the propagation and scattering properties of the sample. We demonstrate that the Jones Matrices are all in the shape of an SU(2) matrix, which is key to understanding the coherent composition of the structural image in PS-OCT and the 2.3 dB SNR improvement. We also discuss a global phase of the Jones matrix in signal multiplexed PS-OCT.
Collapse
|
39
|
Fiber-optic catheter-based polarization-sensitive OCT for radio-frequency ablation monitoring. OPTICS LETTERS 2014; 39:5066-9. [PMID: 25166075 PMCID: PMC4424424 DOI: 10.1364/ol.39.005066] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
An all-fiber optic catheter-based polarization-sensitive optical coherence tomography system is demonstrated. A novel multiplexing method was used to illuminate the sample, splitting the light from a 58.5 kHz Fourier-domain mode-locked laser such that two different polarization states, alternated in time, are generated by two semiconductor optical amplifiers. A 2.3 mm forward-view cone-scanning catheter probe was designed, fabricated, and used to acquire sample scattering intensity and phase retardation images. The system was first verified with a quarter-wave plate and then by obtaining intensity and phase retardation images of high-birefringence plastic, human skin in vivo, and untreated and thermally ablated porcine myocardium ex vivo. The system can potentially in vivo image of the cardiac wall to aid radio-frequency ablation therapy for cardiac arrhythmias.
Collapse
|
40
|
Depth-encoded all-fiber swept source polarization sensitive OCT. BIOMEDICAL OPTICS EXPRESS 2014; 5:2931-49. [PMID: 25401008 PMCID: PMC4230879 DOI: 10.1364/boe.5.002931] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/23/2014] [Accepted: 07/24/2014] [Indexed: 05/18/2023]
Abstract
Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of conventional OCT and can assess depth-resolved tissue birefringence in addition to intensity. Most existing PS-OCT systems are relatively complex and their clinical translation remains difficult. We present a simple and robust all-fiber PS-OCT system based on swept source technology and polarization depth-encoding. Polarization multiplexing was achieved using a polarization maintaining fiber. Polarization sensitive signals were detected using fiber based polarization beam splitters and polarization controllers were used to remove the polarization ambiguity. A simplified post-processing algorithm was proposed for speckle noise reduction relaxing the demand for phase stability. We demonstrated systems design for both ophthalmic and catheter-based PS-OCT. For ophthalmic imaging, we used an optical clock frequency doubling method to extend the imaging range of a commercially available short cavity light source to improve polarization depth-encoding. For catheter based imaging, we demonstrated 200 kHz PS-OCT imaging using a MEMS-tunable vertical cavity surface emitting laser (VCSEL) and a high speed micromotor imaging catheter. The system was demonstrated in human retina, finger and lip imaging, as well as ex vivo swine esophagus and cardiovascular imaging. The all-fiber PS-OCT is easier to implement and maintain compared to previous PS-OCT systems and can be more easily translated to clinical applications due to its robust design.
Collapse
|
41
|
Single input state polarization sensitive swept source optical coherence tomography based on an all single mode fiber interferometer. BIOMEDICAL OPTICS EXPRESS 2014; 5:2798-809. [PMID: 25136503 PMCID: PMC4133007 DOI: 10.1364/boe.5.002798] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2014] [Revised: 06/24/2014] [Accepted: 07/18/2014] [Indexed: 05/19/2023]
Abstract
We present a newly developed single mode fiber based swept source polarization sensitive optical coherence tomography system using a single input state at 1040 nm. Two non-polarizing fiber based beam splitters are combined to form a Mach-Zehnder interferometer, while two polarizing beam splitters are used to obtain a polarization sensitive detection. Both types of beam splitters solely feature conventional single mode fibers. Polarization control paddles are used to set and maintain the polarization states in the fibers of the interferometer and detection unit. By use of a special paddle alignment scheme we are able to eliminate any bulk optic wave plates and polarization maintaining fibers in the interferometer and detection paths while preserving the advantages of a single input state system that illuminates the sample with circularly polarized light. To demonstrate the capabilities of our system, we performed retinal measurements on healthy human volunteers.
Collapse
|
42
|
Fiber-based polarization-sensitive OCT of the human retina with correction of system polarization distortions. BIOMEDICAL OPTICS EXPRESS 2014; 5:2736-58. [PMID: 25136498 PMCID: PMC4133002 DOI: 10.1364/boe.5.002736] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2014] [Revised: 07/11/2014] [Accepted: 07/14/2014] [Indexed: 05/18/2023]
Abstract
In polarization-sensitive optical coherence tomography (PS-OCT) the use of single-mode fibers causes unpredictable polarization distortions which can result in increased noise levels and erroneous changes in calculated polarization parameters. In the current paper this problem is addressed by a new Jones matrix analysis method that measures and corrects system polarization distortions as a function of wavenumber by spectral analysis of the sample surface polarization state and deeper located birefringent tissue structures. This method was implemented on a passive-component depth-multiplexed swept-source PS-OCT system at 1040 nm which was theoretically modeled using Jones matrix calculus. High-resolution B-scan images are presented of the double-pass phase retardation, diattenuation, and relative optic axis orientation to show the benefits of the new analysis method for in vivo imaging of the human retina. The correction of system polarization distortions yielded reduced phase retardation noise, and better estimates of the diattenuation and the relative optic axis orientation in weakly birefringent tissues. The clinical potential of the system is shown by en face visualization of the phase retardation and optic axis orientation of the retinal nerve fiber layer in a healthy volunteer and a glaucoma patient with nerve fiber loss.
Collapse
|
43
|
Polarization-sensitive OFDI using polarization-multiplexed wavelength-swept laser. OPTICS LETTERS 2014; 39:4065-4067. [PMID: 25121652 DOI: 10.1364/ol.39.004065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We demonstrate a novel polarization-sensitive optical frequency domain imaging system employing passive polarization multiplexing. Simple modification of a fiber delay line in the wavelength-swept light source enables illumination with two perpendicular polarizations that are required for determination of the Stokes vector components of the light reflected from each depth of the tissue. This simple all-passive approach provides a robust and low-cost solution for PS imaging replacing relatively complex conventional schemes such as polarization modulation or frequency-encoded polarization multiplexing.
Collapse
|
44
|
Fiber-optic polarization diversity detection for rotary probe optical coherence tomography. OPTICS LETTERS 2014; 39:3638-41. [PMID: 24978556 DOI: 10.1364/ol.39.003638] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We report a polarization diversity detection scheme for optical coherence tomography with a new, custom, miniaturized fiber coupler with single mode (SM) fiber inputs and polarization maintaining (PM) fiber outputs. The SM fiber inputs obviate matching the optical lengths of the X and Y OCT polarization channels prior to interference and the PM fiber outputs ensure defined X and Y axes after interference. Advantages for this scheme include easier alignment, lower cost, and easier miniaturization compared to designs with free-space bulk optical components. We demonstrate the utility of the detection system to mitigate the effects of rapidly changing polarization states when imaging with rotating fiber optic probes in Intralipid suspension and during in vivo imaging of human airways.
Collapse
|
45
|
|
46
|
Optical measurement of arterial mechanical properties: from atherosclerotic plaque initiation to rupture. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:121507. [PMID: 24296995 PMCID: PMC4696609 DOI: 10.1117/1.jbo.18.12.121507] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Revised: 10/09/2013] [Accepted: 10/10/2013] [Indexed: 05/19/2023]
Abstract
During the pathogenesis of coronary atherosclerosis, from lesion initiation to rupture, arterial mechanical properties are altered by a number of cellular, molecular, and hemodynamic processes. There is growing recognition that mechanical factors may actively drive vascular cell signaling and regulate atherosclerosis disease progression. In advanced plaques, the mechanical properties of the atheroma influence stress distributions in the fibrous cap and mediate plaque rupture resulting in acute coronary events. This review paper explores current optical technologies that provide information on the mechanical properties of arterial tissue to advance our understanding of the mechanical factors involved in atherosclerosis development leading to plaque rupture. The optical approaches discussed include optical microrheology and traction force microscopy that probe the mechanical behavior of single cell and extracellular matrix components, and intravascular imaging modalities including laser speckle rheology, optical coherence elastography, and polarization-sensitive optical coherence tomography to measure the mechanical properties of advanced coronary lesions. Given the wealth of information that these techniques can provide, optical imaging modalities are poised to play an increasingly significant role in elucidating the mechanical aspects of coronary atherosclerosis in the future.
Collapse
|
47
|
Spectral binning for mitigation of polarization mode dispersion artifacts in catheter-based optical frequency domain imaging. OPTICS EXPRESS 2013; 21:16353-69. [PMID: 23938487 PMCID: PMC3724396 DOI: 10.1364/oe.21.016353] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Revised: 04/19/2013] [Accepted: 04/21/2013] [Indexed: 05/18/2023]
Abstract
Polarization mode dispersion (PMD) has been recognized as a significant barrier to sensitive and reproducible birefringence measurements with fiber-based, polarization-sensitive optical coherence tomography systems. Here, we present a signal processing strategy that reconstructs the local retardation robustly in the presence of system PMD. The algorithm uses a spectral binning approach to limit the detrimental impact of system PMD and benefits from the final averaging of the PMD-corrected retardation vectors of the spectral bins. The algorithm was validated with numerical simulations and experimental measurements of a rubber phantom. When applied to the imaging of human cadaveric coronary arteries, the algorithm was found to yield a substantial improvement in the reconstructed birefringence maps.
Collapse
|
48
|
Seeing beyond the bronchoscope to increase the diagnostic yield of bronchoscopic biopsy. Am J Respir Crit Care Med 2013; 187:125-9. [PMID: 23322794 DOI: 10.1164/rccm.201208-1483oe] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
|
49
|
Assessment of trabecular meshwork width using swept source optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 2013; 251:1587-92. [PMID: 23436037 DOI: 10.1007/s00417-013-2285-8] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 01/03/2013] [Accepted: 02/07/2013] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Measurements of the angle width by ultrasound biomicroscopy or anterior segment optical coherence tomography are usually performed 500 μm from the scleral spur, as the anterior part of trabecular meshwork (TM) is assumed to lie within this distance. The aim of this study was to measure TM width using swept source optical coherence tomography (SS-OCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan), and to investigate factors influencing this measurement. METHODS Participants underwent gonioscopy and SS-OCT imaging in the dark. High-definition SS-OCT images were corrected for refractive distortion; and customized software (ImageJ; National Institutes of Health, Bethesda, MD, USA) was utilized to measure TM width (distance between the scleral spur and Schwalbe's line). Linear regression analysis was performed to assess the relationship between TM width with demographic and angle parameters. RESULTS One hundred and forty eight Chinese subjects were analyzed. The majority was female (62.4 %); the mean age was 59.2 ± 8.68 years. Identification of the scleral spur and Schwalbe's line with SS-OCT was possible in 590 (99.7 %) and 585 angle quadrants (98.8 %) respectively. TM width was wider in the inferior and superior quadrants (mean 889 [SD 138] and 793 [136] μm), compared to the nasal and temporal quadrants (712 [137] and 724 [115] μm, P<0.001). There was a difference in average TM width between open (789 [100]) and closed angle eyes (753 [86]) (P=0.048). There was no significant association between TM width and angle parameters, laterality, or demographic factors. CONCLUSIONS In SS-OCT HD images, the mean TM width varied from 710 to 890 μm in the different quadrants of the eye, and the inferior quadrant TM was the widest compared to other quadrants.
Collapse
|
50
|
Complex wavefront shaping for optimal depth-selective focusing in optical coherence tomography. OPTICS EXPRESS 2013; 21:2890-902. [PMID: 23481747 DOI: 10.1364/oe.21.002890] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
We report on an approach to exploit multiple light scattering by shaping the incident wavefront in optical coherence tomography (OCT). Most of the reflected signal from biological tissue consists of multiply scattered light, which is regarded as noise in OCT. A digital mirror device (DMD) is utilized to shape the incident wavefront such that the maximal energy is focused at a specific depth in a highly scattering sample using a coherence-gated reflectance signal as feedback. The proof-of-concept experiment demonstrates that this approach enhances depth-selective focusing in the presence of optical inhomogeneity, and thus extends the penetration depth in spectral domain-OCT (SD-OCT).
Collapse
|