1
|
Grating-based x-ray dark-field CT for lung cancer diagnosis in mice. Eur Radiol Exp 2024; 8:12. [PMID: 38270720 PMCID: PMC10810771 DOI: 10.1186/s41747-023-00399-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 10/20/2023] [Indexed: 01/26/2024] Open
Abstract
BACKGROUND The low absorption of x-rays in lung tissue and the poor resolution of conventional computed tomography (CT) limits its use to detect lung disease. However, x-ray dark-field imaging can sense the scattered x-rays deflected by the structures being imaged. This technique can facilitate the detection of small alveolar lesions that would be difficult to detect with conventional CT. Therefore, it may provide an alternative imaging modality to diagnose lung disease at an early stage. METHODS Eight mice were inoculated with lung cancers simultaneously. Each time two mice were scanned using a grating-based dark-field CT on days 4, 8, 12, and 16 after the introduction of the cancer cells. The detectability index was calculated between nodules and healthy parenchyma for both attenuation and dark-field modalities. High-resolution micro-CT and pathological examinations were used to crosscheck and validate our results. Paired t-test was used for comparing the ability of dark-field and attenuation modalities in pulmonary nodule detection. RESULTS The nodules were shown as a signal decrease in the dark-field modality and a signal increase in the attenuation modality. The number of nodules increased from day 8 to day 16, indicating disease progression. The detectability indices of dark-field modality were higher than those of attenuation modality (p = 0.025). CONCLUSIONS Compared with the standard attenuation CT, the dark-field CT improved the detection of lung nodules. RELEVANCE STATEMENT Dark-field CT has a higher detectability index than conventional attenuation CT in lung nodule detection. This technique could improve the early diagnosis of lung cancer. KEY POINTS • Lung cancer progression was observed using x-ray dark-field CT. • Dark-field modality complements with attenuation modality in lung nodule detection. • Dark-field modality showed a detectability index higher than that attenuation in nodule detection.
Collapse
|
2
|
Iterative signal retrieval for X-ray grating interferometry with dual-shot. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:891-901. [PMID: 35694949 DOI: 10.3233/xst-221162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND X-ray grating interferometry normally requires multiple steps and exposures, causing a prolonged imaging time. There is motivation to use fewer steps to reduce scanning time and complexity, while keeping fidelity of the retrieved signals. OBJECTIVE We propose an iterative signal retrieval method, extracting attenuation, dark field contrast (DFC), and differential phase contrast (DPC) signals from two X-ray exposures. METHODS Two shots were captured at G2 grating positions with difference of 1/4 grating period. The algorithm consists of two stages. At the first stage, amplitude of sample phase stepping curve retrieved by virtual phase stepping (VPS) method, visibility and local phase of background phase stepping curve are used to limit the results to the proximity of the ground truth. After the second stage, three high-quality parameters, amplitude, visibility, and local phase, are retrieved through finetuning, and three signals are calculated. Simulated and real-sample experiments were conducted to validate this method. RESULTS We used standard phase stepping result as benchmark and calculated structural similarity (SSIM) and peak signal-to-noise ratio (PSNR) between benchmark and parameters retrieved by our dual-shot method and virtual phase stepping (VPS) method. For both simulated and real-sample experiments, the SSIM and PSNR value of dual-shot method are higher than those of VPS method. For real-sample method, we also conducted a three-step PS, and the SSIM and PSNR value of dual-shot method are slightly lower than those of three-step PS. CONCLUSION Using our dual-shot method demonstrates higher performance than other single-shot method in retrieving high-quality signals, and it also reduces radiation dose and time.
Collapse
|
3
|
Tomoscopy: Time-Resolved Tomography for Dynamic Processes in Materials. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2104659. [PMID: 34558111 DOI: 10.1002/adma.202104659] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 08/26/2021] [Indexed: 06/13/2023]
Abstract
The structure and constitution of opaque materials can be studied with X-ray imaging methods such as 3D tomography. To observe the dynamic evolution of their structure and the distribution of constituents, for example, during processing, heating, mechanical loading, etc., 3D imaging has to be fast enough. In this paper, the recent developments of time-resolved X-ray tomography that have led to what one now calls "tomoscopy" are briefly reviewed A novel setup is presented and applied that pushes temporal resolution down to just 1 ms, that is, 1000 tomograms per second (tps) are acquired, while maintaining spatial resolutions of micrometers and running experiments for minutes without interruption. Applications recorded at different acquisition rates ranging from 50 to 1000 tps are presented. The authors observe and quantify the immiscible hypermonotectic reaction of AlBi10 (in wt%) alloy and dendrite evolution in AlGe10 (in wt%) casting alloy during fast solidification. The combustion process and the evolution of the constituents are analyzed in a burning sparkler. Finally, the authors follow the structure and density of two metal foams over a long period of time and derive details of bubble formation and bubble ageing including quantitative analyses of bubble parameters with millisecond temporal resolution.
Collapse
|
4
|
Single-Shot Multicontrast X-ray Imaging for In Situ Visualization of Chemical Reaction Products. J Imaging 2021; 7:jimaging7110221. [PMID: 34821852 PMCID: PMC8621068 DOI: 10.3390/jimaging7110221] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 10/14/2021] [Accepted: 10/18/2021] [Indexed: 12/02/2022] Open
Abstract
We present the application of single-shot multicontrast X-ray imaging with an inverted Hartmann mask to the time-resolved in situ visualization of chemical reaction products. The real-time monitoring of an illustrative chemical reaction indicated the formation of the precipitate by the absorption, differential phase, and scattering contrast images obtained from a single projection. Through these contrast channels, the formation of the precipitate along the mixing line of the reagents, the border between the solid and the solution, and the presence of the scattering structures of 100–200 nm sizes were observed. The measurements were performed in a flexible and robust setup, which can be tailored to various imaging applications at different time scales.
Collapse
|
5
|
Time-resolved x-ray stroboscopic phase tomography using Talbot interferometer for dynamic deformation measurements. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:043702. [PMID: 34243370 DOI: 10.1063/5.0030811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Accepted: 03/14/2021] [Indexed: 06/13/2023]
Abstract
Time-resolved x-ray phase tomography using a Talbot interferometer and white synchrotron radiation can provide a three-dimensional movie for visualizing the structural change of materials consisting of light elements. In this study, time-resolved x-ray stroboscopic phase tomography using a Talbot interferometer is demonstrated for a vibrating object under 24 Hz compression-stretch fatigue loading. Moiré patterns are recorded by synchronizing drivers for a shutter, grating displacement, and sample rotation with an x-ray camera with a 200 µs exposure, and phase tomograms are reconstructed at specific motion phases of the vibration. The measurement lasts for a few minutes and the δ value changes before breaking, which is considered due to plastic deformation of soft materials under external vibration are depicted three-dimensionally.
Collapse
|
6
|
Proof-of-concept Talbot-Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source. APPLIED OPTICS 2020; 59:8380-8387. [PMID: 32976425 DOI: 10.1364/ao.398839] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 08/17/2020] [Indexed: 06/11/2023]
Abstract
Talbot-Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot-Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot-Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.
Collapse
|
7
|
Abstract
Under the JST-ERATO project in progress to develop X-ray and neutron phase-imaging methods together, recent achievements have been selected and reviewed after describing the merit and the principle of the phase imaging method. For X-ray phase imaging, recent developments of four-dimensional phase tomography and phase microscopy at SPring-8, Japan are mainly presented. For neutron phase imaging, an approach in combination with the time-of-flight method developed at J-PARC, Japan is described with the description of new Gd grating fabrication.
Collapse
|
8
|
Abstract
Since their discovery by Wilhelm Conrad Röntgen in 1895, X-rays have become the most widely available, typically fastest, and usually most cost-effective medical imaging modality today. From the early radiographic approaches using X-ray films as detectors, the portfolio of medical X-ray imaging devices developed into a large range of dedicated instrumentation for various applications. While X-ray imaging has come a long way, there are some physical properties of X-rays, which have not yet been fully exploited, and which may offer quite some room for further enhancements of current X-ray imaging equipment. Firstly, X-ray imaging today is mainly black and white, despite the fact that X-ray generators actually create a full spectrum of X-ray energies, and that the interactions of X-rays that occur within the human body are not the same for all energies and every material. Exploiting these spectral dependencies allows to not only obtain a black and white CT image, but also to obtain more molecularly specific information, which is relevant particularly in oncological precision radiology. The second aspect of X-rays, and so far in radiology mainly neglected and unused, is the physical fact that X-rays can also be interpreted in the wave picture, and not only as presently been done in the particle picture. If interpreted as waves, X-rays-just like visible light-experience a phase shift in matter, and this-if exploited correctly-can produce a new class of X-ray images, which then depict the wave interactions of X-rays with matter, rather than only the attenuating properties, as done until now.
Collapse
|
9
|
Using X-ray tomoscopy to explore the dynamics of foaming metal. Nat Commun 2019; 10:3762. [PMID: 31434878 PMCID: PMC6704127 DOI: 10.1038/s41467-019-11521-1] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 07/15/2019] [Indexed: 11/18/2022] Open
Abstract
The complex flow of liquid metal in evolving metallic foams is still poorly understood due to difficulties in studying hot and opaque systems. We apply X-ray tomoscopy –the continuous acquisition of tomographic (3D) images– to clarify key dynamic phenomena in liquid aluminium foam such as nucleation and growth, bubble rearrangements, liquid retraction, coalescence and the rupture of films. Each phenomenon takes place on a typical timescale which we cover by obtaining 208 full tomograms per second over a period of up to one minute. An additional data processing algorithm provides information on the 1 ms scale. Here we show that bubble coalescence is not only caused by gravity-induced drainage, as experiments under weightlessness show, and by stresses caused by foam growth, but also by local pressure peaks caused by the blowing agent. Moreover, details of foam expansion and phenomena such as rupture cascades and film thinning before rupture are quantified. These findings allow us to propose a way to obtain foams with smaller and more equally sized bubbles. Understanding fast phenomena that happen in hot and opaque environments, such as during metal foaming, remains a challenge. Here, the authors use ultra-fast imaging of more than 200 three-dimensional volumes per second to explore bubble coalescence in an aluminium alloy.
Collapse
|
10
|
High-energy, high-resolution, fly-scan X-ray phase tomography. Sci Rep 2019; 9:8913. [PMID: 31222085 PMCID: PMC6586786 DOI: 10.1038/s41598-019-45561-w] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Accepted: 06/05/2019] [Indexed: 12/03/2022] Open
Abstract
High energy X-ray phase contrast tomography is tremendously beneficial to the study of thick and dense materials with poor attenuation contrast. Recently, the X-ray speckle-based imaging technique has attracted widespread interest because multimodal contrast images can now be retrieved simultaneously using an inexpensive wavefront modulator and a less stringent experimental setup. However, it is time-consuming to perform high resolution phase tomography with the conventional step-scan mode because the accumulated time overhead severely limits the speed of data acquisition for each projection. Although phase information can be extracted from a single speckle image, the spatial resolution is deteriorated due to the use of a large correlation window to track the speckle displacement. Here we report a fast data acquisition strategy utilising a fly-scan mode for near field X-ray speckle-based phase tomography. Compared to the existing step-scan scheme, the data acquisition time can be significantly reduced by more than one order of magnitude without compromising spatial resolution. Furthermore, we have extended the proposed speckle-based fly-scan phase tomography into the previously challenging high X-ray energy region (120 keV). This development opens up opportunities for a wide range of applications where exposure time and radiation dose are critical.
Collapse
|
11
|
A comparative study of information retrieval in grating-based x-ray phase-contrast imaging. ACTA ACUST UNITED AC 2019; 64:125010. [DOI: 10.1088/1361-6560/ab0d5a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
12
|
Development of pink-beam 4D phase CT for in-situ observation of polymers under infrared laser irradiation. Sci Rep 2019; 9:7404. [PMID: 31118428 PMCID: PMC6531456 DOI: 10.1038/s41598-019-43589-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Accepted: 04/24/2019] [Indexed: 11/09/2022] Open
Abstract
Four-dimensional phase computed tomography (4D phase CT) by an X-ray Talbot interferometer (XTI) with white synchrotron radiation has ever been demonstrated at a temporal resolution of about 1 s for soft-matter samples. However, the radiation damage to samples caused by white synchrotron radiation occasionally hampers our understanding of the sample dynamical properties. Based on the fact that XTI functions with X-rays of a bandwidth up to ca. 10% with performance comparable to that by monochromatic X-rays, filtering white synchrotron radiation to generate a 'pink-beam' of a 10% bandwidth is effective to reduce radiation damage without degrading the image quality and temporal resolution. We have therefore developed pink-beam 4D phase CT at SPring-8, Japan by installing a multilayer mirror with a 10% bandwidth and a 25 keV central photon energy. XTI optimal at this photon energy was built downstream, and a CMOS-based X-ray detector was used to achieve fast image acquisitions with an exposure time of 1 ms (or 0.5 ms) per moiré image. The resultant temporal resolution of pink-beam 4D phase CT was 2 s (1 s). We applied the pink-beam 4D phase CT to in-situ observation of polypropylene, poly(methyl methacrylate), and polycarbonate under infrared laser irradiation (1064 nm). The dynamics of melting, bubbling, and ashing were successfully visualized in 3D movies without problematic radiation damage by synchrotron radiation.
Collapse
|
13
|
Technical Note: Single-shot phase retrieval method for synchrotron-based high-energy x-ray grating interferometry. Med Phys 2019; 46:1317-1322. [DOI: 10.1002/mp.13399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 11/20/2018] [Accepted: 01/18/2019] [Indexed: 01/31/2023] Open
|
14
|
Single-image phase retrieval for hard X-ray grating interferometry. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:215-219. [PMID: 30655487 DOI: 10.1107/s1600577518016727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 11/24/2018] [Indexed: 06/09/2023]
Abstract
A single-image method is proposed for quantitative phase retrieval in hard X-ray grating interferometry. This novel method assumes a quasi-homogeneous sample, with a constant ratio between the real and imaginary parts of its complex refractive index. The method is first theoretically derived and presented, and then validated by synchrotron radiation experiments. Compared with the phase-stepping method, the presented approach abandons grating scanning and multiple image acquisition, and is therefore advantageous in terms of its simplified acquisition procedure and reduced data-collection times, which are especially important for applications such as in vivo imaging and phase tomography. Moreover, the sample's phase image, instead of its first derivative, is directly retrieved. In particular, the stripe artifacts encountered in the integrated phase images are significantly suppressed. The improved quality of the retrieved phase images can be beneficial for image interpretation and subsequent processing. Owing to its requirement for a single image and its robustness against noise, the present method is expected to find use in potential investigations in diverse applications.
Collapse
|
15
|
Hard X-ray imaging microscopy with self-imaging phenomenon. Microscopy (Oxf) 2018; 67:303-316. [PMID: 30307556 DOI: 10.1093/jmicro/dfy040] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Accepted: 09/11/2018] [Indexed: 11/12/2022] Open
Abstract
The self-imaging phenomenon referred to as the Talbot effect in the field of optics was discovered by H.F. Talbot in the 1830s, and is now widely used for imaging using not only visible light but also X-rays, electrons, neutrons, and matter waves. In this review, the author introduces the current progress being made in hard-X-ray imaging microscopy based on the self-imaging phenomenon. Hard-X-ray imaging microscopy is a promising technique for non-destructively visualizing internal structures in specimens with a spatial resolution up to a few tens of nanometers. The use of the self-imaging phenomenon makes it possible to realize highly sensitive phase-contrast X-ray imaging microscopes. These approaches have several advantages over conventional X-ray imaging microscopes, including the widely used Zernike X-ray phase-contrast microscopes, and can provide a powerful way of quantitative visualization with a high spatial resolution and a high sensitivity even for thick specimens.
Collapse
|
16
|
Simultaneous X-ray radioscopy/tomography and energy-dispersive diffraction applied to liquid aluminium alloy foams. JOURNAL OF SYNCHROTRON RADIATION 2018; 25:1790-1796. [PMID: 30407191 DOI: 10.1107/s1600577518011657] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Accepted: 08/17/2018] [Indexed: 06/08/2023]
Abstract
High-speed X-ray imaging in two dimensions (radioscopy) and three dimensions (tomography) is combined with fast X-ray diffraction in a new experimental setup at the synchrotron radiation source BESSY II. It allows for in situ studies of time-dependent phenomena in complex systems. As a first application, the foaming process of an aluminium alloy was studied in three different experiments. Radioscopy, optical expansion measurements and diffraction were used to correlate the change of foam morphology to the various phases formed during heating of an AlMg15Cu10 alloy to 620°C in the first experiment. Radioscopy was then replaced by tomography. Acquiring tomograms and diffraction data at 2 Hz allows even more details of foam evolution to be captured, for example, bubble size distribution. In a third experiment, 4 Hz tomography yields dynamic insights into fast phenomena in evolving metal foam.
Collapse
|
17
|
Single-shot Talbot-Lau x-ray dark-field imaging of a porcine lung applying the moiré imaging approach. Phys Med Biol 2018; 63:185010. [PMID: 30117437 DOI: 10.1088/1361-6560/aadafe] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Talbot-Lau x-ray imaging provides additionally to the conventional attenuation image, two further images: the differential phase-contrast image which is especially sensitive to differences in refractive properties and the dark-field image which is showing the x-ray scattering properties of the object. Thus, in the dark-field image sub-pixeled object information can be observed. As it has been shown in recent studies, this is of special interest for lung imaging. Changes in the alveoli structure, which are in the size of one detector pixel, can be seen in the dark-field images. A fast acquisition process is crucial to avoid motion artifacts due to heartbeat and breathing of the patient. Using moiré imaging the images can be acquired with a single-shot exposure. Nevertheless, the spatial resolution is reduced compared to the phase-stepping acquisition. We evaluate the results of both imaging techniques towards their feasibility in clinical routine. Furthermore, we analyse the influence of artificial linear object movement on the image quality, in order to simulate the heartbeat of a patient.
Collapse
|
18
|
Time-resolved in situ tomography for the analysis of evolving metal-foam granulates. JOURNAL OF SYNCHROTRON RADIATION 2018; 25:1505-1508. [PMID: 30179190 DOI: 10.1107/s1600577518008949] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Accepted: 06/19/2018] [Indexed: 06/08/2023]
Abstract
An experimental setup has been developed that allows for capturing up to 25 tomograms s-1 using the white X-ray beam at the experimental station EDDI of BESSY II, Berlin, Germany. The key points are the use of a newly developed, precise and fast rotation stage, a very efficient scintillator and a fast CMOS camera. As a first application, the foaming of aluminium alloy granules at 923 K was investigated in situ. Formation and growth of bubbles in the liquid material were observed and found to be influenced by the limited thermal conductivity in the bulk granules. Changes that took place between two tomographic frames separated in time by 39 ms could be detected and analysed quantitatively.
Collapse
|
19
|
A Shack-Hartmann Sensor for Single-Shot Multi-Contrast Imaging with Hard X-rays. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8050737] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
20
|
Improved Reconstruction Technique for Moiré Imaging Using an X-Ray Phase-Contrast Talbot–Lau Interferometer. J Imaging 2018. [DOI: 10.3390/jimaging4050062] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
21
|
Diagnosis of breast cancer based on microcalcifications using grating-based phase contrast CT. Eur Radiol 2018; 28:3742-3750. [DOI: 10.1007/s00330-017-5158-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Revised: 10/19/2017] [Accepted: 10/26/2017] [Indexed: 10/18/2022]
|
22
|
Effect of insufficient temporal coherence on visibility contrast in X-ray grating interferometry. OPTICS EXPRESS 2018; 26:1012-1027. [PMID: 29401974 DOI: 10.1364/oe.26.001012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Accepted: 01/04/2018] [Indexed: 06/07/2023]
Abstract
X-ray grating interferometry, which has been spotlighted in the last decade as a multi-modal X-ray imaging technique, can provide three independent images, i.e., absorption, differential-phase, and visibility-contrast images. We report on a cause of the visibility contrast, an effect of insufficient temporal coherence, that can be observed when continuous-spectrum X-rays are used. This effect occurs even for a sample without unresolvable random structures, which are known as the main causes of visibility contrast. We performed an experiment using an acrylic cylinder and quantitatively explained the visibility contrast due to this effect.
Collapse
|
23
|
Talbot-Lau x-ray deflectometry phase-retrieval methods for electron density diagnostics in high-energy density experiments. APPLIED OPTICS 2018; 57:138-145. [PMID: 29328157 DOI: 10.1364/ao.57.000138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Talbot-Lau x-ray interferometry uses incoherent x-ray sources to measure refraction index changes in matter. These measurements can provide accurate electron density mapping through phase retrieval. An adaptation of the interferometer has been developed in order to meet the specific requirements of high-energy density experiments. This adaptation is known as a moiré deflectometer, which allows for single-shot capabilities in the form of interferometric fringe patterns. The moiré x-ray deflectometry technique requires a set of object and reference images in order to provide electron density maps, which can be costly in the high-energy density environment. In particular, synthetic reference phase images obtained ex situ through a phase-scan procedure, can provide a feasible solution. To test this procedure, an object phase map was retrieved from a single-shot moiré image obtained from a plasma-produced x-ray source. A reference phase map was then obtained from phase-stepping measurements using a continuous x-ray tube source in a small laboratory setting. The two phase maps were used to retrieve an electron density map. A comparison of the moiré and phase-stepping phase-retrieval methods was performed to evaluate single-exposure plasma electron density mapping for high-energy density and other transient plasma experiments. It was found that a combination of phase-retrieval methods can deliver accurate refraction angle mapping. Once x-ray backlighter quality is optimized, the ex situ method is expected to deliver electron density mapping with improved resolution. The steps necessary for improved diagnostic performance are discussed.
Collapse
|
24
|
In situ X-ray tomography of aqueous foams: Analysis of columnar foam generation. Colloids Surf A Physicochem Eng Asp 2017. [DOI: 10.1016/j.colsurfa.2017.03.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
25
|
Grating-based phase-contrast and dark-field computed tomography: a single-shot method. Sci Rep 2017; 7:7476. [PMID: 28785015 PMCID: PMC5547164 DOI: 10.1038/s41598-017-06729-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 06/15/2017] [Indexed: 11/19/2022] Open
Abstract
Grating-based X-ray interferometry offers vast potential for imaging materials and tissues that are not easily visualised using conventional X-ray imaging. Tomographic reconstruction based on X-ray interferometric data provides not only access to the attenuation coefficient of an object, but also the refractive index and information about ultra-small-angle scattering. This improved functionality comes at the cost of longer measurement times because existing projection-based signal extraction algorithms require not only a single measurement per projection angle but several with precise grating movements in between. This obstacle hinders the adaptation of grating-based interferometry into a continuously rotating gantry. Several solutions to this problem have been proposed but all suffer from major drawbacks. We present results using an iterative reconstruction algorithm working directly on the interferograms. The suggested direct approach enables improved image quality, since interpolations and unnecessary assumptions about the object are circumvented. Our results demonstrate that it is possible to successfully reconstruct the linear attenuation coefficient, the refractive index and the linear diffusion coefficient, which is a measure related to ultra-small-angle scattering, using a single measurement per projection angle and without any grating movements. This is a milestone for future clinical implementation of grating-based phase-contrast and dark-field contrast X-ray computed tomography.
Collapse
|
26
|
Phase retrieval with the reverse projection method in the presence of object's scattering. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2015.12.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
27
|
Four dimensional material movies: High speed phase-contrast tomography by backprojection along dynamically curved paths. Sci Rep 2017; 7:6487. [PMID: 28747663 PMCID: PMC5529574 DOI: 10.1038/s41598-017-06333-6] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Accepted: 06/12/2017] [Indexed: 11/09/2022] Open
Abstract
We present an approach towards four dimensional (4d) movies of materials, showing dynamic processes within the entire 3d structure. The method is based on tomographic reconstruction on dynamically curved paths using a motion model estimated by optical flow techniques, considerably reducing the typical motion artefacts of dynamic tomography. At the same time we exploit x-ray phase contrast based on free propagation to enhance the signal from micron scale structure recorded with illumination times down to a millisecond (ms). The concept is demonstrated by observing the burning process of a match stick in 4d, using high speed synchrotron phase contrast x-ray tomography recordings. The resulting movies reveal the structural changes of the wood cells during the combustion.
Collapse
|
28
|
Development toward high-resolution X-ray phase imaging. Microscopy (Oxf) 2017; 66:155-166. [PMID: 28430991 DOI: 10.1093/jmicro/dfx013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Accepted: 03/27/2017] [Indexed: 06/07/2023] Open
Abstract
Since the 1990s, the use of X-ray phase contrast has been extensively studied for imaging weakly absorbing objects consisting of low-Z elements such as biological soft tissues and polymers. The development of X-ray microscopy was also progressing during this time, although absorption contrast was only available. It was straightforward and important to develop phase-contrast X-ray microscopy. One characteristic in the development is that quantitative phase measurement is possible through the acquisition of phase-contrast images under a specific procedure, thanks to digital X-ray image detectors. Therefore, such a technique is called 'phase imaging' rather than phase-contrast imaging in this review. Highly sensitive three-dimensional phase imaging is feasible in combination with tomography. This article reviews the progress in X-ray phase imaging, especially with regards to X-ray microscopy.
Collapse
|
29
|
Increased x-ray attenuation in malignant vs. benign mediastinal nodes in an orthotopic model of lung cancer. Diagn Interv Radiol 2017; 22:35-9. [PMID: 26611258 DOI: 10.5152/dir.2015.15220] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE Staging of lung cancer is typically performed with fluorodeoxyglucose-positron emission tomography-computed tomography (FDG-PET/CT); however, false positive PET scans can occur due to inflammatory disease. The CT scan is used for anatomic registration and attenuation correction. Herein, we evaluated x-ray attenuation (XRA) within nodes on CT and correlated this with the presence of malignancy in an orthotopic lung cancer model in rats. METHODS 1×10⁶ NCI-H460 cells were injected transthoracically in six National Institutes of Health nude rats and six animals served as controls. After two weeks, animals were sacrificed; lymph nodes were extracted and scanned with a micro-CT to determine their XRA prior to histologic analysis. RESULTS Median CT density in malignant lymph nodes (n=20) was significantly higher than benign lymph nodes (n=12; P = 0.018). Short-axis diameter of metastatic lymph nodes was significantly different than benign nodes (3.4 mm vs. 2.4 mm; P = 0.025). Area under the curve for malignancy was higher for density-based lymph node analysis compared with size measurements (0.87 vs. 0.7). CONCLUSION XRA of metastatic mediastinal lymph nodes is significantly higher than benign nodes in this lung cancer model. This suggests that information on nodal density may be useful when used in combination with the results of FDG-PET in determining the likelihood of malignant adenopathy.
Collapse
|
30
|
Monochromatic-beam-based dynamic X-ray microtomography based on OSEM-TV algorithm. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2017; 25:1007-1017. [PMID: 28777770 DOI: 10.3233/xst-17279] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Monochromatic-beam-based dynamic X-ray computed microtomography (CT) was developed to observe evolution of microstructure inside samples. However, the low flux density results in low efficiency in data collection. To increase efficiency, reducing the number of projections should be a practical solution. However, it has disadvantages of low image reconstruction quality using the traditional filtered back projection (FBP) algorithm. In this study, an iterative reconstruction method using an ordered subset expectation maximization-total variation (OSEM-TV) algorithm was employed to address and solve this problem. The simulated results demonstrated that normalized mean square error of the image slices reconstructed by the OSEM-TV algorithm was about 1/4 of that by FBP. Experimental results also demonstrated that the density resolution of OSEM-TV was high enough to resolve different materials with the number of projections less than 100. As a result, with the introduction of OSEM-TV, the monochromatic-beam-based dynamic X-ray microtomography is potentially practicable for the quantitative and non-destructive analysis to the evolution of microstructure with acceptable efficiency in data collection and reconstructed image quality.
Collapse
|
31
|
4D x-ray phase contrast tomography for repeatable motion of biological samples. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:093705. [PMID: 27782563 DOI: 10.1063/1.4962405] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm3. A maximum volume size of 13 × 13 × 6 mm3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.
Collapse
|
32
|
Anisotropic shrinkage of insect air sacs revealed in vivo by X-ray microtomography. Sci Rep 2016; 6:32380. [PMID: 27580585 PMCID: PMC5007674 DOI: 10.1038/srep32380] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2016] [Accepted: 07/26/2016] [Indexed: 11/09/2022] Open
Abstract
Air sacs are thought to be the bellows for insect respiration. However, their exact mechanism of action as a bellows remains unclear. A direct way to investigate this problem is in vivo observation of the changes in their three-dimensional structures. Therefore, four-dimensional X-ray phase contrast microtomography is employed to solve this puzzle. Quantitative analysis of three-dimensional image series reveals that the compression of the air sac during respiration in bell crickets exhibits obvious anisotropic characteristics both longitudinally and transversely. Volumetric changes of the tracheal trunks in the prothorax further strengthen the evidence of this finding. As a result, we conclude that the shrinkage and expansion of the insect air sac is anisotropic, contrary to the hypothesis of isotropy, thereby providing new knowledge for further research on the insect respiratory system.
Collapse
|
33
|
Abstract
OBJECTIVE The objective of this study was to assess the potential of grating-based phase-contrast computed tomography (gb-PCCT) for the detection and characterization of human coronary artery disease in an experimental ex vivo validation study. MATERIALS AND METHODS The study was approved by the institutional review board, and informed consent was obtained from all patients. Specimens were examined using a conventional low-coherence x-ray tube (40 kV) and a Talbot-Lau grating interferometer. Histopathologic assessment was used as the standard of reference. Signal characteristics of calcified, fibrous (FIB), and lipid-rich (LIP) tissue were visually and quantitatively assessed by phase-contrast Hounsfield units (HU). Conventional absorption-based HU values were also measured. Conservative measurements of diagnostic accuracy for the detection and differentiation of plaque components as well as quantitative measurements of vessel dimensions were obtained, and receiver operating characteristic curve analysis for plaque differentiation was performed. RESULTS A total of 15 coronary arteries from 5 subjects were available for analysis (386 sections). Calcified, FIB, and LIP displayed distinct gb-PCCT signal criteria. The diagnostic accuracy of gb-PCCT was high with sensitivity, specificity, and negative and positive predictive values of 0.89 or greater for all plaque components with good interrater agreement (к ≥ 0.88). In addition, quantitative measurements of vessel dimensions in gb-PCCT were strongly correlated with measurements obtained from histopathology (Pearson R ≥ 0.86). Finally, phase-contrast Hounsfield units were superior to conventional HU in differentiating FIB and LIP (receiver operating characteristic analysis, 0.86 vs. 0.77, respectively; P < 0.05). CONCLUSIONS In an ex vivo setting, gb-PCCT provides improved differentiation and quantification of coronary atherosclerotic plaque and may thus serve as a tool for nondestructive histopathology.
Collapse
|
34
|
Abstract
Microscopy techniques using visible photons, x-rays, neutrons, and electrons have made remarkable impact in many scientific disciplines. The microscopic data can often be expressed as the convolution of the spatial distribution of certain properties of the specimens and the inherent response function of the imaging system. The x-ray grating interferometer (XGI), which is sensitive to the deviation angle of the incoming x-rays, has attracted significant attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the comprehensive and analytical theoretical framework is yet to be presented. Herein, we propose a theoretical framework termed angular signal radiography (ASR) to describe the imaging process of the XGI system in a classical, comprehensive and analytical manner. We demonstrated, by means of theoretical deduction and synchrotron based experiments, that the spatial distribution of specimens' physical properties, including absorption, refraction and scattering, can be extracted by ASR in XGI. Implementation of ASR in XGI offers advantages such as simplified phase retrieval algorithm, reduced overall radiation dose, and improved image acquisition speed. These advantages, as well as the limitations of the proposed method, are systematically investigated in this paper.
Collapse
|
35
|
AHA classification of coronary and carotid atherosclerotic plaques by grating-based phase-contrast computed tomography. Eur Radiol 2015; 26:3223-33. [PMID: 26679184 DOI: 10.1007/s00330-015-4143-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2015] [Revised: 07/20/2015] [Accepted: 11/30/2015] [Indexed: 10/22/2022]
Abstract
OBJECTIVES To evaluate the potential of grating-based phase-contrast computed-tomography (gb-PCCT) to classify human carotid and coronary atherosclerotic plaques according to modified American Heart Association (AHA) criteria. METHODS Experiments were carried out at a laboratory-based set-up consisting of X-ray tube (40 kVp), grating-interferometer and detector. Eighteen human carotid and coronary artery specimens were examined. Histopathology served as the standard of reference. Vessel cross-sections were classified as AHA lesion type I/II, III, IV/V, VI, VII or VIII plaques by two independent reviewers blinded to histopathology. Conservative measurements of diagnostic accuracies for the detection and differentiation of plaque types were evaluated. RESULTS A total of 127 corresponding gb-PCCT/histopathology sections were analyzed. Based on histopathology, lesion type I/II was present in 12 (9.5 %), III in 18 (14.2 %), IV/V in 38 (29.9 %), VI in 16 (12.6 %), VII in 34 (26.8 %) and VIII in 9 (7.0 %) cross-sections. Sensitivity, specificity and positive and negative predictive value were ≥0.88 for most analyzed plaque types with a good level of agreement (Cohen's kappa = 0.90). Overall, results were better in carotid (kappa = 0.97) than in coronary arteries (kappa = 0.85). Inter-observer agreement was high with kappa = 0.85, p < 0.0001. CONCLUSIONS These results indicate that gb-PCCT can reliably classify atherosclerotic plaques according to modified AHA criteria with excellent agreement to histopathology. KEY POINTS • Different atherosclerotic plaque types display distinct morphological features in phase-contrast CT. • Phase-contrast CT can detect and differentiate AHA plaque types. • Calcifications caused streak artefacts and reduced sensitivity in type VI lesions. • Overall agreement was higher in carotid than in coronary arteries.
Collapse
|
36
|
Abstract
X-rays are commonly used as a means to image the inside of objects opaque to visible light, as their short wavelength allows penetration through matter and the formation of high spatial resolution images. This physical effect has found particular importance in medicine where x-ray based imaging is routinely used as a diagnostic tool. Increasingly, however, imaging modalities that provide functional as well as morphological information are required. In this study the potential to use x-ray phase based imaging as a functional modality through the use of microbubbles that can be targeted to specific biological processes is explored. We show that the concentration of a microbubble suspension can be monitored quantitatively whilst in flow using x-ray phase contrast imaging. This could provide the basis for a dynamic imaging technique that combines the tissue penetration, spatial resolution, and high contrast of x-ray phase based imaging with the functional information offered by targeted imaging modalities.
Collapse
|
37
|
Abstract
Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. The method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.
Collapse
|
38
|
Slit-scanning differential x-ray phase-contrast mammography: Proof-of-concept experimental studies. Med Phys 2015; 42:1959-65. [DOI: 10.1118/1.4914420] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
39
|
Quantitative and dynamic measurements of biological fresh samples with X-ray phase contrast tomography. JOURNAL OF SYNCHROTRON RADIATION 2014; 21:1347-57. [PMID: 25343804 PMCID: PMC4421879 DOI: 10.1107/s1600577514018128] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Accepted: 08/07/2014] [Indexed: 05/24/2023]
Abstract
X-ray phase contrast tomography using a Talbot grating interferometer was applied to biological fresh samples which were not fixed by any fixatives. To achieve a high-throughput measurement for the fresh samples the X-ray phase contrast tomography measurement procedure was improved. The three-dimensional structure of a fresh mouse fetus was clearly depicted as a mass density map using X-ray phase contrast tomography. The mouse fetus measured in the fresh state was then fixed by formalin and measured in the fixed state. The influence of the formalin fixation on soft tissue was quantitatively evaluated by comparing the fresh and fixed samples. X-ray phase contrast tomography was also applied to the dynamic measurement of a biological fresh sample. Morphological changes of a ring-shaped fresh pig aorta were measured tomographically under different degrees of stretching.
Collapse
|
40
|
Phase contrast portal imaging using synchrotron radiation. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:073704. [PMID: 25085143 DOI: 10.1063/1.4885755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Microbeam radiation therapy is an experimental form of radiation treatment with great potential to improve the treatment of many types of cancer. We applied a synchrotron radiation phase contrast technique to portal imaging to improve targeting accuracy for microbeam radiation therapy in experiments using small animals. An X-ray imaging detector was installed 6.0 m downstream from an object to produce a high-contrast edge enhancement effect in propagation-based phase contrast imaging. Images of a mouse head sample were obtained using therapeutic white synchrotron radiation with a mean beam energy of 130 keV. Compared to conventional portal images, remarkably clear images of bones surrounding the cerebrum were acquired in an air environment for positioning brain lesions with respect to the skull structure without confusion with overlapping surface structures.
Collapse
|
41
|
|
42
|
A phase demodulation method for two-dimensional grating-based X-ray interferometry. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2014; 372:20130034. [PMID: 24470416 DOI: 10.1098/rsta.2013.0034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This paper presents a novel approach to achieving high spatial resolution in the demodulation of images produced by a two-dimensional X-ray Talbot interferometry (XTI) system. Currently, demodulation of XTI images is mainly performed by either phase-stepping (PS) or Fourier transform (FT) methods. However, the PS method for two-dimensional XTI demodulation requires a larger number of exposures and a more complex grating control process than that of one-dimensional XTI. On the other hand, although the FT method uses only a single-fringe image, it gives lower spatial resolution than the PS method. For practical application of two-dimensional XTI, a simpler exposure process with high spatial resolution is required. In this paper, we introduce a hybrid method combining the PS and FT methods. This method simplifies the exposure process in comparison with the PS method required in two-dimensional XTI while achieving higher spatial resolution than the FT method in the demodulation of images. The method works by using additional exposures to eliminate unnecessary spectral components that appear in the FT method. Furthermore, the proposed method is demonstrated by using actual two-dimensional XTI data and shown to achieve high spatial resolution in the demodulation of images for both the x- and y-differential phase components.
Collapse
|
43
|
Abstract
Scientific cinematography using ultrafast optical imaging is a common tool to study motion. In opaque organisms or structures, X-ray radiography captures sequences of 2D projections to visualize morphological dynamics, but for many applications full four-dimensional (4D) spatiotemporal information is highly desirable. We introduce in vivo X-ray cine-tomography as a 4D imaging technique developed to study real-time dynamics in small living organisms with micrometer spatial resolution and subsecond time resolution. The method enables insights into the physiology of small animals by tracking the 4D morphological dynamics of minute anatomical features as demonstrated in this work by the analysis of fast-moving screw-and-nut-type weevil hip joints. The presented method can be applied to a broad range of biological specimens and biotechnological processes.
Collapse
|
44
|
Phase-contrast CT: qualitative and quantitative evaluation of atherosclerotic carotid artery plaque. Radiology 2014; 271:870-8. [PMID: 24588675 DOI: 10.1148/radiol.14131554] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the potential of phase-contrast computed tomography (CT) for atherosclerotic plaque imaging in human carotid arteries in an experimental ex vivo study. MATERIALS AND METHODS The study was approved by the institutional review board, and informed consent was obtained from the patients' relatives. Seven postmortem human carotid artery specimens were imaged at a laboratory setup by using a conventional x-ray tube and grating interferometer. After histologic processing, phase-contrast imaging and histopathologic data were matched. Characteristics of the necrotic core (NC) covered by a fibrous cap (FC), intraplaque hemorrhage (IPH), and calcifications (CAs) were established, and sensitivity, specificity, and accuracy of phase-contrast CT for plaque detection and the potential for accurate quantification were assessed. The Cohen κ and Pearson correlation coefficient R were used to determine the agreement between phase-contrast imaging and histopathologic findings for plaque characterization and correlation of quantitative plaque measurements, respectively. A difference with a P value of less than .05 was considered significant. RESULTS Characteristic criteria were found in all analyzed plaque components. Applying these criteria, phase-contrast CT had a good sensitivity for the detection of the FC and NC, IPH, and CAs (all, >80%) and excellent specificity and accuracy (all, >90%), with good interreader agreement (κ ≥ 0.72, P < .0001). There were excellent correlations for quantitative measurements of FC, NC, and CAs between phase-contrast imaging and histopathologic findings (R ≥ 0.92). Interreader reproducibility was excellent, with an intraclass correlation coefficient of 0.98 or higher for all measurements. CONCLUSION The results of this study indicate that ex vivo phase-contrast CT can help identify and quantify atherosclerotic plaque components, with excellent correlation to histopathologic findings. Although not yet applicable in vivo, phase-contrast CT may become a valuable tool to monitor atherosclerotic disease process noninvasively.
Collapse
|
45
|
Single-shot x-ray phase imaging with grating interferometry and photon-counting detectors. OPTICS LETTERS 2014; 39:877-879. [PMID: 24562230 DOI: 10.1364/ol.39.000877] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this Letter, we present a single-shot approach to quantitatively retrieve x-ray absorption and phase shift in grating interferometry. The proposed approach makes use of the energy-resolving capability of x-ray photon-counting detectors. The retrieval method is derived and presented and is tested based on numerical simulations, including photon shot noise. The good agreement between retrieval results and theoretical values confirms the feasibility of the presented approach.
Collapse
|
46
|
|
47
|
Non-binary phase gratings for x-ray imaging with a compact Talbot interferometer. OPTICS EXPRESS 2014; 22:547-556. [PMID: 24515015 DOI: 10.1364/oe.22.000547] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
X-ray imaging using a Talbot-Lau interferometer, consisting of three binary gratings, is a well-established approach to acquire x-ray phase-contrast and dark-field images with a polychromatic source. However, challenges in the production of high aspect ratio gratings limit the construction of a compact setup for high x-ray energies. In this study we consider the use of phase gratings with triangular-shaped structures in an x-ray interferometer and show that such gratings can yield high visibilities for significantly shorter propagation distances than conventional gratings with binary structures. The findings are supported by simulation and experimental results for both cases of a monochromatic and a polychromatic source.
Collapse
|
48
|
|
49
|
|
50
|
Grating-based X-ray phase contrast for biomedical imaging applications. Z Med Phys 2013; 23:176-85. [PMID: 23453793 DOI: 10.1016/j.zemedi.2013.02.002] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2012] [Revised: 01/31/2013] [Accepted: 02/05/2013] [Indexed: 02/01/2023]
Abstract
In this review article we describe the development of grating-based X-ray phase-contrast imaging, with particular emphasis on potential biomedical applications of the technology. We review the basics of image formation in grating-based phase-contrast and dark-field radiography and present some exemplary multimodal radiography results obtained with laboratory X-ray sources. Furthermore, we discuss the theoretical concepts to extend grating-based multimodal radiography to quantitative transmission, phase-contrast, and dark-field scattering computed tomography.
Collapse
|