1
|
Yang X, Jia M, Xiao G, Chai Q, Zhou R, Romashko RV, Zhang J. FBG array based wavelength calibration scheme for Fourier domain mode-locked laser with pm resolution and hourly stability. OPTICS EXPRESS 2022; 30:45393-45399. [PMID: 36522945 DOI: 10.1364/oe.475043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Accepted: 11/09/2022] [Indexed: 06/17/2023]
Abstract
We demonstrate a fiber Bragg grating (FBG) array based wavelength calibration scheme for Fourier domain mode-locked (FDML) laser. The wavelength interval and the temperature feedback module of the FBG array are designed to ensure the reference stability of the wavelength calibration scheme. Combined with the calibration scheme, the FDML laser with a tunable wavelength range of ∼60 nm, a center wavelength of 1300 nm and a sweep frequency of 39.63 kHz is built up to demonstrate its feasibility. The FBG wavelength demodulation based on the calibrated FDML laser system shows a wavelength resolution of 2.76 pm and hourly stability of 10.22 pm.
Collapse
|
2
|
Lee GH, Ahn S, Kim MS, Lee SW, Kim JS, Choi BK, Pagidi S, Jeon MY. Output Characterization of 220 nm Broadband 1250 nm Wavelength-Swept Laser for Dynamic Optical Fiber Sensors. SENSORS (BASEL, SWITZERLAND) 2022; 22:8867. [PMID: 36433461 PMCID: PMC9696297 DOI: 10.3390/s22228867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/14/2022] [Accepted: 11/15/2022] [Indexed: 06/16/2023]
Abstract
Broadband wavelength-swept lasers (WSLs) are widely used as light sources in biophotonics and optical fiber sensors. Herein, we present a polygonal mirror scanning wavelength filter (PMSWF)-based broadband WSL using two semiconductor optical amplifiers (SOAs) with different center wavelengths as the gain medium. The 10-dB bandwidth of the wavelength scanning range with 3.6 kHz scanning frequency was approximately 223 nm, from 1129 nm to 1352 nm. When the scanning frequency of the WSL was increased, the intensity and bandwidth decreased. The main reason for this is that the laser oscillation time becomes insufficient as the scanning frequency increases. We analyzed the intensity and bandwidth decrease according to the increase in the scanning frequency in the WSL through the concept of saturation limit frequency. In addition, optical alignment is important for realizing broadband WSLs. The optimal condition can be determined by analyzing the beam alignment according to the position of the diffraction grating and the lenses in the PMSWF. This broadband WSL is specially expected to be used as a light source in broadband distributed dynamic FBG fiber-optic sensors.
Collapse
Affiliation(s)
- Gi Hyen Lee
- Department of Physics, College of Natural Sciences, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Soyeon Ahn
- Department of Physics, College of Natural Sciences, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Min Su Kim
- Department of Physics, College of Natural Sciences, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Sang Won Lee
- Department of Physics, College of Natural Sciences, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Ji Su Kim
- Department of Physics, College of Natural Sciences, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Byeong Kwon Choi
- Department of Physics, College of Natural Sciences, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Srinivas Pagidi
- Institute of Quantum Systems (IQS), Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Min Yong Jeon
- Department of Physics, College of Natural Sciences, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
- Institute of Quantum Systems (IQS), Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| |
Collapse
|
3
|
Cense B, Maddipatla R, Cervantes Lozano FJ, Joo C. Two concepts for ultra-high-resolution polarization-sensitive optical coherence tomography with a single camera. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2022; 39:1295-1308. [PMID: 36215616 DOI: 10.1364/josaa.458631] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 06/12/2022] [Indexed: 06/16/2023]
Abstract
Two designs with a multiplexed superluminescent diode for ultra-high-resolution spectral-domain polarization-sensitive optical coherence tomography (UHR-PS-OCT) are introduced. In the first design, a Wollaston prism separates orthogonal polarization states next to each other on one linescan camera; the other design uses a beam displacer to separate orthogonal states onto two lines of a linescan camera with multiple rows of detectors. The coherence lengths measured with the two systems were 3.6 µm and 2.9 µm (n=1.38), respectively. Measurements were collected from the fovea of a healthy subject, a healthy subject with astigmatism, and a patient with central serous retinopathy (CSR). A single volumetric scan provides double pass retardance induced by the retinal nerve fiber layer birefringence (RNFL) and its birefringence, the cumulative double pass retardance induced by the Henle fiber layer, and the retardance that is induced by the retinal pigment epithelium-Bruch's membrane complex. The high axial resolution in UHR-PS-OCT is particularly helpful for the measurements of thin retinal tissue, such as the RNFL in the fovea, where birefringence values of around 1°/µm were found. Tilting of the retina due to a CSR or by off centering the imaging beam in the pupil causes an artificial increase in the double pass retardance induced by the RNFL and Henle fiber layer.
Collapse
|
4
|
Output Stabilization of Wavelength-Swept Laser Based on Closed-Loop Control of Fabry-Pérot Tunable Wavelength Filter for Fiber-Optic Sensors. SENSORS 2022; 22:s22124337. [PMID: 35746118 PMCID: PMC9230916 DOI: 10.3390/s22124337] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 05/30/2022] [Accepted: 06/07/2022] [Indexed: 01/18/2023]
Abstract
The output of a wavelength-swept laser (WSL) based on a fiber Fabry–Pérot tunable filter (FFP-TF) tends to shift the peak wavelength due to external temperature or heat generated by the FFP-TF itself. Therefore, when measuring the output of WSL for a long time, it is very difficult to accurately measure a signal in the temporal domain corresponding to a specific wavelength of the output of the WSL. If the wavelength variation of the WSL output can be predicted through the peak time information of the forward scan or the backward scan from the WSL, the variation of the peak wavelength can be compensated for by adjusting the offset voltage applied to the FFP-TF. This study presents a successful stabilization method for peak wavelength variation in WSLs by adjusting the offset voltage of the FFP-TF with closed-loop control. The closed-loop control is implemented by measuring the deviation in the WSL peak position in the temporal domain using the trigger signal of the function generator. The feedback repetition rate for WSL stabilization was approximately 0.2 s, confirming that the WSL output and the peak position for the fiber Bragg grating (FBG) reflection spectrum were kept constant within ±7 μs at the maximum when the stabilization loop was applied. The standard deviations of WSL output and reflection peak positions were 1.52 μs and 1.59 μs, respectively. The temporal and spectral domains have a linear relationship; the ±7 μs maximum variation of the peak position corresponded to ±0.035 nm of the maximum wavelength variation in the spectral domain. The proposed WSL system can be used as a light source for temperature or strain-dependent sensors as it compensates for the WSL wavelength variation in applications that do not require a fast scanning rate.
Collapse
|
5
|
de Wit J, Angelopoulos K, Kalkman J, Glentis GO. Fast and accurate spectral-estimation axial super-resolution optical coherence tomography. OPTICS EXPRESS 2021; 29:39946-39966. [PMID: 34809348 DOI: 10.1364/oe.439761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 10/28/2021] [Indexed: 06/13/2023]
Abstract
Spectral-estimation OCT (SE-OCT) is a computational method to enhance the axial resolution beyond the traditional bandwidth limit. However, it has not yet been used widely due to its high computational load, dependency on user-optimized parameters, and inaccuracy in intensity reconstruction. In this study, we implement SE-OCT using a fast implementation of the iterative adaptive approach (IAA). This non-parametric spectral estimation method is optimized for use on OCT data. Both in simulations and experiments we show an axial resolution improvement with a factor between 2 and 10 compared to standard discrete Fourier transform. Contrary to parametric methods, IAA gives consistent peak intensity and speckle statistics. Using a recursive and fast reconstruction scheme the computation time is brought to the sub-second level for a 2D scan. Our work shows that SE-OCT can be used for volumetric OCT imaging in a reasonable computation time, thus paving the way for wide-scale implementation of super-resolution OCT.
Collapse
|
6
|
Okawa Y, Hotate K. Computed tomography for distributed Brillouin sensing. OPTICS EXPRESS 2021; 29:35067-35077. [PMID: 34808950 DOI: 10.1364/oe.435320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 09/29/2021] [Indexed: 06/13/2023]
Abstract
A method to reconstruct the spatial distribution of Brillouin gain spectrum from its Radon transform is proposed, which is a type of optical computed tomography. To verify the concept, an experiment was performed on distributed Brillouin fiber sensing, which succeeded in detecting a 55-cm strain section along a 10-m fiber. The experimental system to obtain the Radon transform of the Brillouin gain spectrum is based on a Brillouin optical correlation-domain analysis with a linear frequency-modulated continuous-wave laser. Combining distributed fiber sensing with computed tomography, this method can realize a high signal-to-noise ratio Brillouin sensing.
Collapse
|
7
|
1.1-µm Band Extended Wide-Bandwidth Wavelength-Swept Laser Based on Polygonal Scanning Wavelength Filter. SENSORS 2021; 21:s21093053. [PMID: 33925592 PMCID: PMC8141112 DOI: 10.3390/s21093053] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/21/2021] [Accepted: 04/26/2021] [Indexed: 12/03/2022]
Abstract
We demonstrated a 1.1-µm band extended wideband wavelength-swept laser (WSL) that combined two semiconductor optical amplifiers (SOAs) based on a polygonal scanning wavelength filter. The center wavelengths of the two SOAs were 1020 nm and 1140 nm, respectively. Two SOAs were connected in parallel in the form of a Mach-Zehnder interferometer. At a scanning speed of 1.8 kHz, the 10-dB bandwidth of the spectral output and the average power were approximately 228 nm and 16.88 mW, respectively. Owing to the nonlinear effect of the SOA, a decrease was observed in the bandwidth according to the scanning speed. Moreover, the intensity of the WSL decreased because the oscillation time was smaller than the buildup time. In addition, a cholesteric liquid crystal (CLC) cell was fabricated as an application of WSL, and the dynamic change of the first-order reflection of the CLC cell in the 1-µm band was observed using the WSL. The pitch jumps of the reflection band occurred according to the electric field applied to the CLC cell, and instantaneous changes were observed.
Collapse
|
8
|
Soliton microcomb based spectral domain optical coherence tomography. Nat Commun 2021; 12:427. [PMID: 33462200 PMCID: PMC7813855 DOI: 10.1038/s41467-020-20404-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 11/05/2020] [Indexed: 12/22/2022] Open
Abstract
Spectral domain optical coherence tomography (OCT) is a widely employed, minimally invasive bio-medical imaging technique, which requires a broadband light source, typically implemented by super-luminescent diodes. Recent advances in soliton based photonic integrated frequency combs (soliton microcombs) have enabled the development of low-noise, broadband chipscale frequency comb sources, whose potential for OCT imaging has not yet been unexplored. Here, we explore the use of dissipative Kerr soliton microcombs in spectral domain OCT and show that, by using photonic chipscale Si3N4 resonators in conjunction with 1300 nm pump lasers, spectral bandwidths exceeding those of commercial OCT sources are possible. We characterized the exceptional noise properties of our source (in comparison to conventional OCT sources) and demonstrate that the soliton states in microresonators exhibit a residual intensity noise floor at high offset frequencies that is ca. 3 dB lower than a traditional OCT source at identical power, and can exhibit significantly lower noise performance for powers at the milli-Watt level. Moreover, we demonstrate that classical amplitude noise of all soliton comb teeth are correlated, i.e., common mode, in contrast to superluminescent diodes or incoherent microcomb states, which opens a new avenue to improve imaging speed and performance beyond the thermal noise limit. Superluminescent diodes, that provide a broadband spectrum are typically used in spectral domain coherence tomography. Here, the authors use chipscale silicon nitride resonators to generate soliton microcombs with a lower noise flor that could substitute the diode sources.
Collapse
|
9
|
Ko MO, Kim SJ, Kim JH, Jeon MY. In situobservation of dynamic pitch jumps of in-planar cholesteric liquid crystal layers based on wavelength-swept laser. OPTICS EXPRESS 2018; 26:28751-28762. [PMID: 30470047 DOI: 10.1364/oe.26.028751] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 10/15/2018] [Indexed: 06/09/2023]
Abstract
We report in situ observation of dynamic pitch jumps in cholesteric liquid crystal (CLC) layers that depend on the applied electric field. A high-speed and wide bandwidth wavelength-swept laser is used as an optical broadband source to measure the dynamic pitch jumps. We could not observe the dynamic pitch jump in the quasi-static pitch variation. Instead, we carry out two driving methods, a normal driving and an overdriving method, in order to measure the dynamic pitch jump in the CLC cell. For the case of normal driving, it has been confirmed that the reflection band from the measurement region is discontinuously shifted by movement of the defect wall. The reflection band was compressed and recovered before the band moved, but the dynamic pitch jump of the helix could not be observed. For the case of overdriving, however, it was possible to observe the unwinding of the helix during the dynamic pitch jump. The entire dynamic pitch jump process in the CLC cell could be observed by measuring the transmission spectra from the CLC cell by varying the applied electric field. We confirm that the entire reaction time with the overdriving method was about 800 ms, which was shorter than with the normal driving method. This study contributes to the development of fast in-plane switching research and the development of new CLC devices.
Collapse
|
10
|
DiLazaro T, Nehmetallah G. Large-volume, low-cost, high-precision FMCW tomography using stitched DFBs. OPTICS EXPRESS 2018; 26:2891-2904. [PMID: 29401823 DOI: 10.1364/oe.26.002891] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Accepted: 01/24/2018] [Indexed: 06/07/2023]
Abstract
Optical frequency-modulated continuous-wave (FMCW) reflectometry is a ranging technique that allows for high-resolution distance measurements over long ranges. Similarly, swept-source optical coherence tomography (SS-OCT) provides high-resolution depth imaging over typically shorter distances and higher scan speeds. In this work, we demonstrate a low-cost, low-bandwidth 3D imaging system that provides the high axial resolution imaging capability normally associated with SS-OCT over typical FMCW ranging depths. The imaging system combines 12 distributed feedback laser (DFB) elements from a single butterfly module to provide an axial resolution of 27.1 μm over 6 m of depth and up to 14 cubic meters of volume. Active sweep linearization is used, greatly reducing the signal processing overhead. Various sub-surface, OCT-style tomograms of semi-transparent objects are shown, as well as 3D maps of various objects over depths ranging from sub-millimeter to several meters. Such imaging capability would make long-distance, high-resolution surface interrogation possible in a low-cost, compact package.
Collapse
|