Ye X, Gu Y, Bai Y, Xia S, Zhang Y, Lou Y, Zhu Y, Dai Y, Tsoi JKH, Wang S. Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies. Front Bioeng Biotechnol 2021; 9:626892. [PMID: 33987172 PMCID: PMC8111077 DOI: 10.3389/fbioe.2021.626892] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 03/29/2021] [Indexed: 01/19/2023] Open
Abstract
Being as a non-pharmacological medical intervention, low-magnitude high-frequency vibration (LMHFV) has shown a positive effect on bone induction and remodeling for various muscle diseases in animal studies, among which dental implants osteointegration were reported to be improved as well. However, whether LMHFV can be clinically used in dental implant is still unknown. In this study, efficacy, parameters and side effects of LMHFV were analyzed via data before 15th July 2020, collecting from MEDLINE/PubMed, Embase, Ovid and Cochrane Library databases. In the screened 1,742 abstracts and 45 articles, 15 animal studies involving 972 implants were included. SYRCLE's tool was performed to assess the possible risk of bias for each study. The GRADE approach was applied to evaluate the quality of evidence. Random effects meta-analysis detected statistically significant in total BIC (P < 0.0001) and BV/TV (P = 0.001) upon loading LMHFV on implants. To conclude, LMHFV played an active role on BIC and BV/TV data according to the GRADE analysis results (medium and low quality of evidence). This might illustrate LMHFV to be a worthy way in improving osseointegration clinically, especially for osteoporosis. Systematic Review Registration:https://www.crd.york.ac.uk/PROSPERO, identifier: NCT02612389
Collapse
Affiliation(s)
- Xinjian Ye
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| | - Ying Gu
- Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Pokfulam, Hong Kong
| | - Yijing Bai
- The First Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, China
| | - Siqi Xia
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| | - Yujia Zhang
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| | - Yuwei Lou
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| | - Yuchi Zhu
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| | - Yuwei Dai
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| | - James Kit-Hon Tsoi
- Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Pokfulam, Hong Kong
| | - Shuhua Wang
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China.,Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| |
Collapse
|
2
|
Nelson K, Hesse B, Addison O, Morrell AP, Gross C, Lagrange A, Suárez VI, Kohal R, Fretwurst T. Distribution and Chemical Speciation of Exogenous Micro- and Nanoparticles in Inflamed Soft Tissue Adjacent to Titanium and Ceramic Dental Implants. Anal Chem 2020; 92:14432-14443. [PMID: 32970419 DOI: 10.1021/acs.analchem.0c02416] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Degradation of the implant surface and particle release/formation as an inflammation catalyst mechanism is an emerging concept in dental medicine that may help explain the pathogenesis of peri-implantitis. The aim of the present study was a synchrotron-based characterization of micro- and nanosized implant-related particles in inflamed human tissues around titanium and ceramic dental implants that exhibited signs of peri-implantitis. Size, distribution, and chemical speciation of the exogenous micro- and nanosized particle content were evaluated using synchrotron μ-X-ray fluorescence spectroscopy (XRF), nano-XRF, and μ-X-ray absorption near-edge structure (XANES). Titanium particles, with variable speciation, were detected in all tissue sections associated with titanium implants. Ceramic particles were found in five out of eight tissue samples associated with ceramic implants. Particles ranged in size from micro- to nanoscale. The local density of both titanium and ceramic particles was calculated to be as high as ∼40 million particles/mm3. μ-XANES identified titanium in predominantly two different chemistries, including metallic and titanium dioxide (TiO2). The findings highlight the propensity for particle accumulation in the inflamed tissues around dental implants and will help in guiding toxicological studies to determine the biological significance of such exposures.
Collapse
Affiliation(s)
- Katja Nelson
- Department of Oral- and Craniomaxillofacial Surgery/Translational Implantology, Faculty of Medicine, Medical Center-University of Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany
| | - Bernhard Hesse
- Xploraytion GmbH, Bismarckstrasse 10-12, 10625 Berlin, Germany.,European Synchrotron Radiation Facility (ESRF), 71 avenue des Martyrs, 38043 Grenoble, France
| | - Owen Addison
- Centre for Oral, Clinical & Translational Sciences, Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, Guy's Hospital, Great Maze Pond, SE1 9RT London, U.K
| | - Alexander P Morrell
- Centre for Oral, Clinical & Translational Sciences, Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, Guy's Hospital, Great Maze Pond, SE1 9RT London, U.K
| | - Christian Gross
- Department of Oral- and Craniomaxillofacial Surgery/Translational Implantology, Faculty of Medicine, Medical Center-University of Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany
| | - Adrien Lagrange
- Xploraytion GmbH, Bismarckstrasse 10-12, 10625 Berlin, Germany
| | - Vanessa I Suárez
- European Synchrotron Radiation Facility (ESRF), 71 avenue des Martyrs, 38043 Grenoble, France
| | - Ralf Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center-University of Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany
| | - Tobias Fretwurst
- Department of Oral- and Craniomaxillofacial Surgery/Translational Implantology, Faculty of Medicine, Medical Center-University of Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany
| |
Collapse
|
3
|
Zhou C, Chen Y, Zhu Y, Lin G, Zhang L, Liu X, He F. Antiadipogenesis and Osseointegration of Strontium-Doped Implant Surfaces. J Dent Res 2019; 98:795-802. [PMID: 31136719 DOI: 10.1177/0022034519850574] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The decreased bone density and increased marrow adiposity that occur with aging may influence the outcome of dental implants. Strontium (Sr), an anabolic agent for the treatment of osteoporosis, has an inhibitory effect on adipogenesis but favors osteogenesis of bone marrow–derived mesenchymal stem cells (BMSCs). However, little is known about the effects and mechanisms of local Sr release on adipogenesis during bone formation in aged bone. In this study, a potential dental implant material, Sr-doped titanium, was developed via a sandblasted, large-grit, and acid-etched (SLA) method combined with a hydrothermal process. The effects of Sr-SLA on initial adhesion, proliferation, intracellular redox state, and adipogenic differentiation of senescent BMSCs were investigated. The in vitro results showed that Sr-SLA promoted spreading of senescent BMSCs via upregulation of the gene and protein expression of integrin β1. In addition, it was revealed that Sr-SLA could reduce intracellular oxidative stress by decreasing the levels of reactive oxygen species and oxygen radicals and increasing the content of glutathione peroxidase. More important, Sr-SLA suppressed lipid droplet production and adipokines expression via downregulation of transcription peroxisome proliferator-activated receptor γ (PPARγ) and signal transducer and activator of transcription 1, thus inhibiting adipogenesis. Finally, the Sr-SLA implants were implanted in tibiae of aged (18-mo-old) Sprague-Dawley rats for 2 and 8 wk. Histomorphometric analysis demonstrated that Sr-SLA implants significantly enhanced osseointegration, and the inhibition effect on marrow adipose tissue formation was moderate. All these results suggest that due to the multiple functions produced by Sr, antiadipogenesis capability and rapid osseointegration were enhanced by the Sr-SLA coatings, which have potential application in dental implantation in the aged population.
Collapse
Affiliation(s)
- C. Zhou
- Department of Prothodontics, The Affiliated Stomatology Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Y.Q. Chen
- Department of Prothodontics, The Affiliated Stomatology Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Y.H. Zhu
- Department of Prothodontics, The Affiliated Stomatology Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - G.F. Lin
- Department of General Dentistry, The Affiliated Stomatology Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - L.F. Zhang
- Department of Prothodontics, The Affiliated Stomatology Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - X.C. Liu
- Department of Prothodontics, The Affiliated Stomatology Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - F.M. He
- Department of Oral Implantology and Prosthodontics, The Affiliated Stomatology Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|
4
|
Wang S, Ogawa T, Zheng S, Miyashita M, Tenkumo T, Gu Z, Lian W, Sasaki K. The effect of low-magnitude high-frequency loading on peri-implant bone healing and implant osseointegration in Beagle dogs. J Prosthodont Res 2018; 62:497-502. [PMID: 30139715 DOI: 10.1016/j.jpor.2018.07.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 06/04/2018] [Accepted: 07/10/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE Low-magnitude, high-frequency (LMHF) loading plays an important role in bone healing. The present study aimed to evaluate the effect of LMHF loading applied directly to titanium dental implants on peri-implant bone healing and implant osseointegration. METHODS The mandibular premolars and molars were extracted from six male Beagle dogs. Three months post-extraction, each of the six dogs had three titanium implants (Aadva Standard Implant Narrow, Φ3.3×8mm) inserted into the mandibular premolar and molar area (three implants per side). In each animal, one side was randomly selected to undergo daily LMHF loading (treatment group), while the other side had no further intervention (control). The loading was applied directly to the implant abutment using an individual jig and a custom-made loading device (8μm, 100Hz). The implant stability quotient (ISQ) was tested every week. Three dogs were euthanized after 2 weeks, and three were euthanized after 8 weeks. Tissue samples were fixed and stained for micro-computed tomography (micro-CT) and histomorphometric analyses. Data were analyzed statistically, with significance set at p<0.05. RESULTS The treatment group had significantly increased peri-implant bone volume relative to tissue volume in region of interest 2 (100-500μm) compared with the control group after 2 weeks of loading (p<0.05); however, there was no significant difference between groups after 8 weeks. The ISQ value and the micro-CT results did not differ between groups during the study period. CONCLUSIONS LMHF loading positively influenced peri-implant bone healing in the early healing period.
Collapse
Affiliation(s)
- Shuhua Wang
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan; School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Toru Ogawa
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan.
| | - Sheng Zheng
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan; School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Makiko Miyashita
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Taichi Tenkumo
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Zhiyuan Gu
- School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Wenhai Lian
- School of Stomatology, Hangzhou Normal University, Hangzhou, Zhejiang, China
| | - Keiichi Sasaki
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
| |
Collapse
|
5
|
Ida H, Seiryu M, Takeshita N, Iwasaki M, Yokoyama Y, Tsutsumi Y, Ikeda E, Sasaki S, Miyashita S, Sasaki S, Fukunaga T, Deguchi T, Takano-Yamamoto T. Biosafety, stability, and osteogenic activity of novel implants made of Zr 70Ni 16Cu 6Al 8 bulk metallic glass for biomedical application. Acta Biomater 2018; 74:505-517. [PMID: 29772348 DOI: 10.1016/j.actbio.2018.05.020] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Revised: 05/11/2018] [Accepted: 05/12/2018] [Indexed: 01/22/2023]
Abstract
Superior mechanical and chemical properties of Zr70Ni16Cu6Al8 bulk metallic glass (BMG) demonstrate its promise as a novel biomaterial for fabrication of implants. The aim of the present study was to validate mechanical, chemical, and biological properties of Zr70Ni16Cu6Al8 BMG through comparison with titanium (Ti). Our data indicated higher tensile strength, lower Young's modulus, and reduced metal ion release of Zr70Ni16Cu6Al8 BMG compared with Ti. Biosafety of bone marrow mesenchymal cells on Zr70Ni16Cu6Al8 BMG was comparable to that of Ti. Next, screw-type implant prototypes made of Zr70Ni16Cu6Al8 BMG were fabricated and inserted into rat long bones. Zr70Ni16Cu6Al8 BMG implants indicated a higher removal-torque value and lower Periotest value compared with Ti implants. In addition, higher amounts of new bone formation and osseointegration were observed around Zr70Ni16Cu6Al8 BMG implants compared with Ti implants. Moreover, gene expression analysis displayed higher expression of osteoblast- and osteoclast-associated genes in the Zr70Ni16Cu6Al8 BMG group compared with the Ti group. Importantly, loading to implants upregulated bone formation, as well as osteoblast- and osteoclast-associated gene expression in the peri-implant area. No significant difference in concentrations of Ni, Al, Cu, and Zr in various organs was shown between in the Zr70Ni16Cu6Al8 BMG and Ti groups. Collectively, these findings suggest that Zr70Ni16Cu6Al8 BMG is suitable for fabricating novel implants with superior mechanical properties, biocompatibility, stability, and biosafety compared with Ti. STATEMENT OF SIGNIFICANCE Titanium is widely used to fabricate orthopedic and dental implants. However, Titanium has disadvantages for biomedical applications in regard to strength, elasticity, and biosafety. Recently, we developed a novel hypoeutectic Zr70Ni16Cu6Al8 BMG, which has superior mechanical and chemical properties. However, the validity of Zr70Ni16Cu6Al8 BMG for biomedical application has not been cleared. The aim of the present study was to validate the mechanical, chemical, and biological properties of Zr70Ni16Cu6Al8 BMG for biomedical applications through comparison with Titanium. The present study clarifies that Zr70Ni16Cu6Al8 BMG has good mechanical properties, corrosion resistance, and osteogenic activity, which are necessary features for biomedical applications. The present study provides for the first time the superiority of Zr70Ni16Cu6Al8 BMG implants to Titanium implants for biomedical applications.
Collapse
|
6
|
Shibamoto A, Ogawa T, Duyck J, Vandamme K, Naert I, Sasaki K. Effect of high-frequency loading and parathyroid hormone administration on peri-implant bone healing and osseointegration. Int J Oral Sci 2018. [PMID: 29531334 PMCID: PMC5944597 DOI: 10.1038/s41368-018-0009-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The objective of this study is to examine the effect of low-magnitude, high-frequency (LMHF) loading, and anti-osteoporosis medications such as parathyroid hormone (PTH) and bisphosphonates on peri-implant bone healing in an osteoporosis model, and to assess their combined effects on these processes. Thirteen-week-old ovariectomized rats (n = 44) were divided into three groups: PTH, alendronate, and saline. After 3 weeks of drug administration, titanium implants were inserted into the tibiae. Each group was subdivided into two groups: with or without LMHF loading via whole-body vibration (50 Hz at 0.5 g, 15 min per day, 5 days per week). Rats were killed 4 weeks following implantation. Removal torque test, micro-CT analyses (relative gray (RG) value, water = 0, and implant = 100), and histomorphometric analyses (bone-to-implant contact (BIC) and peri-implant bone formation (bone volume/tissue volume (BV/TV))) were performed. Removal torque values and BIC were significantly differed by loading and drug administration (ANOVA). Post hoc analysis showed that PTH-treated groups were significantly higher than the other drug-treated groups. BV/TV was significantly enhanced by PTH administration. In cortical bone, RG values were significantly increased by loading. In trabecular bone, however, RG values were significantly increased by PTH administration. These findings suggest that LMHF loading and PTH can act locally and additively on the bone healing process, improving the condition of implant osseointegration. Whole-body vibration and administration of a hormone used to treat osteoporosis can enhance bone healing at the site of a titanium implant. Toru Ogawa of Tohoku University Graduate School of Dentistry in Sendai, Japan, and colleagues gave anti-osteoporosis medications, either parathyroid hormone or the bisphosphonate drug alendronate, to female rat models of osteoporosis. After three weeks of drug administration or a saline control, the researchers inserted titanium implants into the rats’ leg bones. Half the rats were then exposed to whole-body vibration, which applies low-magnitude, high-frequency mechanical forces. A multitude of tests showed that parathyroid hormone improved bone healing at the implant more than alendronate or saline did. The vibrational stimulus further increased the healing. The findings suggest that these treatments could aid in oral bone healing for patients receiving dental implants.
Collapse
Affiliation(s)
- Aya Shibamoto
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Toru Ogawa
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan.
| | - Joke Duyck
- Department of Oral Health Sciences, Prosthetic Dentistry, BIOMAT-Biomaterials, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Katleen Vandamme
- Department of Oral Health Sciences, Prosthetic Dentistry, BIOMAT-Biomaterials, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Ignace Naert
- Department of Oral Health Sciences, Prosthetic Dentistry, BIOMAT-Biomaterials, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Keiichi Sasaki
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
| |
Collapse
|
7
|
Histochemical examination on the peri-implant bone with early occlusal loading after the immediate placement into extraction sockets. Histochem Cell Biol 2018; 149:433-447. [DOI: 10.1007/s00418-018-1644-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/30/2018] [Indexed: 01/20/2023]
|
8
|
Li Z, Müller R, Ruffoni D. Bone remodeling and mechanobiology around implants: Insights from small animal imaging. J Orthop Res 2018; 36:584-593. [PMID: 28975660 DOI: 10.1002/jor.23758] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Accepted: 09/27/2017] [Indexed: 02/04/2023]
Abstract
Anchorage of orthopedic implants depends on the interfacial bonding between the implant and the host bone as well as on the mass and microstructure of peri-implant bone, with all these factors being continuously regulated by the biological process of bone (re)modeling. In osteoporotic bone, implant integration may be jeopardized not only by lower peri-implant bone quality but also by reduced intrinsic regeneration ability. The first aim of this review is to provide a critical overview of the influence of osteoporosis on bone regeneration post-implantation. Mechanical stimulation can trigger bone formation and inhibit bone resorption; thus, judicious administration of mechanical loading can be used as an effective non-pharmacological treatment to enhance implant anchorage. Our second aim is to report recent achievements on the application of external mechanical stimulation to improve the quantity of peri-implant bone. The review focuses on peri-implant bone changes in osteoporotic conditions and following mechanical loading, prevalently using small animals and in vivo monitoring approaches. We intend to demonstrate the necessity to reveal new biological information on peri-implant bone mechanobiology to better target implant anchorage and fracture fixation in osteoporotic conditions. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:584-593, 2018.
Collapse
Affiliation(s)
- Zihui Li
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Ralph Müller
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Davide Ruffoni
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland.,Mechanics of Biological and Bioinspired Materials Laboratory, Department of Aerospaceand Mechanical Engineering, University of Liège, Liège, Belgium
| |
Collapse
|
9
|
Feng SW, Ho KN, Chan YH, Chang KJ, Lai WY, Huang HM. Damping Factor as a Diagnostic Parameter for Assessment of Osseointegration during the Dental Implant Healing Process: An Experimental Study in Rabbits. Ann Biomed Eng 2016; 44:3668-3678. [DOI: 10.1007/s10439-016-1675-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2016] [Accepted: 06/07/2016] [Indexed: 11/30/2022]
|
10
|
Liang YQ, Qi MC, Xu J, Xu J, Liu HW, Dong W, Li JY, Hu M. Low-magnitude high-frequency loading, by whole-body vibration, accelerates early implant osseointegration in ovariectomized rats. Mol Med Rep 2014; 10:2835-42. [PMID: 25270245 PMCID: PMC4227418 DOI: 10.3892/mmr.2014.2597] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2013] [Accepted: 07/04/2014] [Indexed: 01/12/2023] Open
Abstract
Osteoporosis deteriorates jaw bone quality and may compromise early implant osseointegration and early implant loading. The influence of low-magnitude, high-frequency (LMHF) vibration on peri-implant bone healing and implant integration in osteoporotic bones remains poorly understood. LMHF loading via whole-body vibration (WBV) for 8 weeks has previously been demonstrated to significantly enhance bone-to-implant contact, peri-implant bone fraction and implant mechanical properties in osteoporotic rats. In the present study, LMHF loading by WBV was performed in osteoporotic rats, with a loading duration of 4 weeks during the early stages of bone healing. The results indicated that 4-week LMHF loading by WBV partly reversed the negative effects of osteoporosis and accelerated early peri-implant osseointegration in ovariectomized rats.
Collapse
Affiliation(s)
- Yong-Qiang Liang
- Department of Stomatology, Chinese PLA General Hospital, Beijing 100853, P.R. China
| | - Meng-Chun Qi
- College of Stomatology, Hebei United University, Tangshan, Hebei 063000, P.R. China
| | - Jiang Xu
- Department of Stomatology, Tongchuan City People's Hospital, Tongchuan, Shaanxi 727100, P.R. China
| | - Juan Xu
- Department of Stomatology, Chinese PLA General Hospital, Beijing 100853, P.R. China
| | - Hua-Wei Liu
- Department of Stomatology, Chinese PLA General Hospital, Beijing 100853, P.R. China
| | - Wei Dong
- College of Stomatology, Hebei United University, Tangshan, Hebei 063000, P.R. China
| | - Jin-Yuan Li
- College of Stomatology, Hebei United University, Tangshan, Hebei 063000, P.R. China
| | - Min Hu
- Department of Stomatology, Chinese PLA General Hospital, Beijing 100853, P.R. China
| |
Collapse
|
11
|
Wang S, Liu Y, Tang Y, Zhao W, Li J, Yang Y, Du W, Yu H. Direct Radial LMHF Microvibration Induced Bone Formation and Promoted Implant Osseointegration. Clin Implant Dent Relat Res 2014; 18:401-9. [PMID: 24852608 DOI: 10.1111/cid.12220] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Mechanical loading is known to play an important role in bone remodeling. PURPOSE This study aimed to evaluate the effect of direct low-magnitude high-frequency (LMHF) microvibration on dental implant bone formation and osseointegration. MATERIALS AND METHODS Titanium implants were installed in rabbit tibiae. The implants in the left legs were loaded with mechanical vibration (15 μm) at 10, 20, 30, and 40 Hz (10, 20, 30, and 40 Hz groups, respectively) for 30 minutes every day. The implants on the right legs were used as a sham control and did not receive a vibration load. RESULTS After 20 days, the 10, 20, and 30 Hz groups showed significantly greater newly formed bone volume, density, ratio of the bone surface area to the trabecular bone surface area, and ratio of the bone surface area in direct contact with osteoclasts versus the total bone surface area in the region of interest compared with the sham control group, especially the 20 Hz group. However, the 40 Hz group did not. CONCLUSIONS In conclusion, the application of direct LMHF (10, 20, or 30 Hz) vibration on the implants promoted bone formation and osseointegration, especially at 20 Hz; however, the use of 40 Hz did not result in any significant improvement.
Collapse
Affiliation(s)
- Shirui Wang
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yang Liu
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yi Tang
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Wei Zhao
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Junying Li
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yang Yang
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Wen Du
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Haiyang Yu
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
12
|
Mathieu V, Vayron R, Richard G, Lambert G, Naili S, Meningaud JP, Haiat G. Biomechanical determinants of the stability of dental implants: influence of the bone-implant interface properties. J Biomech 2013; 47:3-13. [PMID: 24268798 DOI: 10.1016/j.jbiomech.2013.09.021] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 09/18/2013] [Accepted: 09/24/2013] [Indexed: 12/19/2022]
Abstract
Dental implants are now widely used for the replacement of missing teeth in fully or partially edentulous patients and for cranial reconstructions. However, risks of failure, which may have dramatic consequences, are still experienced and remain difficult to anticipate. The stability of biomaterials inserted in bone tissue depends on multiscale phenomena of biomechanical (bone-implant interlocking) and of biological (mechanotransduction) natures. The objective of this review is to provide an overview of the biomechanical behavior of the bone-dental implant interface as a function of its environment by considering in silico, ex vivo and in vivo studies including animal models as well as clinical studies. The biomechanical determinants of osseointegration phenomena are related to bone remodeling in the vicinity of the implants (adaptation of the bone structure to accommodate the presence of a biomaterial). Aspects related to the description of the interface and to its space-time multiscale nature will first be reviewed. Then, the various approaches used in the literature to measure implant stability and the bone-implant interface properties in vitro and in vivo will be described. Quantitative ultrasound methods are promising because they are cheap, non invasive and because of their lower spatial resolution around the implant compared to other biomechanical approaches.
Collapse
Affiliation(s)
- Vincent Mathieu
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Romain Vayron
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Gilles Richard
- Septodont, 58 Rue Pont de Créteil, 94100 Saint-Maur-des-Fossés, France
| | - Grégory Lambert
- Septodont, 58 Rue Pont de Créteil, 94100 Saint-Maur-des-Fossés, France
| | - Salah Naili
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Jean-Paul Meningaud
- Service de Chirurgie Plastique, Reconstructrice et Esthétique, CHU H. Mondor, 94017 Créteil cedex, France
| | - Guillaume Haiat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France.
| |
Collapse
|