1
|
Grote L, Jonzon YA, Barta P, Murto T, Nilsson Z, Nygren A, Theorell-Haglöw J, Sunnergren O, Ulander M, Ekström M, Palm A, Hedner J. The Swedish sleep apnea registry (SESAR) cohort - "Real world data" on a national level. Sleep Med 2024; 124:362-370. [PMID: 39378545 DOI: 10.1016/j.sleep.2024.09.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 09/12/2024] [Accepted: 09/28/2024] [Indexed: 10/10/2024]
Abstract
INTRODUCTION The Swedish Sleep Apnea Registry (SESAR) collects clinical data from individual obstructive sleep apnea (OSA) patients since 2010. SESAR has recently been integrated with additional national healthcare data. The current analysis presents the SESAR structure and representative clinical data of a national sleep apnea cohort. METHODS Clinical data from unselected patients with a diagnosis of OSA are submitted to the SESAR registry. 48 sleep centers report data from diagnosis, treatment starts with Continuous Positive Airway Pressure (CPAP), oral devices (OD), and Upper Airway Surgery (UAS). Data from follow-up are included. SESAR is linked to mandatory national healthcare data (mortality, comorbidities, procedures, prescriptions) and diagnosis-specific quality registries (e.g. stroke, heart failure, diabetes) within the DISCOVERY project. RESULTS 83,404 OSA patients have been reported during the diagnostic workup (age 55.4 ± 14.1 years, BMI 30.8 ± 6.5 kg/m2, AHI 25.8 ± 21.6n/h, respectively). At least one cardiometabolic and respiratory comorbidity is recognized in 57 % of female and 53 % of male OSA patients with a linear increase across OSA severity. In 54,468, 7,797, and 390 patients, start of CPAP, OD or UAS treatment is reported, respectively. OD patients have 4 units lower BMI and 10 units lower AHI compared to patients started on CPAP. UAS patients are characterized by 10 years lower age. The degree of daytime sleepiness is comparable between treatment groups with mean Epworth Sleepiness Scale Scores between 9 and 10. CONCLUSION SESAR is introduced as a large national registry of OSA patients. SESAR provides a useful tool to highlight OSA management and to perform relevant outcome research.
Collapse
Affiliation(s)
- Ludger Grote
- Center for Sleep and Wake Disorders, Institute of Medicine, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden; Pulmonary Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden.
| | | | - Peter Barta
- Home Mechanical Ventilation Unit, Pulmonary Medicine, University Hospital, Örebro, Sweden.
| | - Tarmo Murto
- Sleep Apnea Unit, Respiratory Medicine, Umeå University Hospital, Umeå, Sweden.
| | - Zarita Nilsson
- Sleep Apnea Unit, ENT Department, Ystad Hospital, Ystad, Sweden.
| | - Anna Nygren
- Sleep Apnea Unit, Pulmonary Department, Central Hospital, Västerås, Sweden.
| | - Jenny Theorell-Haglöw
- Respiratory, Allergy and Sleep Research, Department of Medical Sciences, Uppsala University, Uppsala, Sweden.
| | - Ola Sunnergren
- Department of Otorhinolaryngology, Head and Neck Surgery, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Otorhinolaryngology- Head and Neck Surgery, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg, Sweden.
| | - Martin Ulander
- Department for Clinical Neurophysiology, Linköping University Hospital, Linköping, Sweden; Division of Neurobiology, Department of Biomedicine and Clinical Sciences, Linköping University, Linköping, Sweden.
| | - Magnus Ekström
- Department of Clinical Sciences Lund, Respiratory Medicine, Lund University, Lund, Sweden.
| | - Andreas Palm
- Respiratory, Allergy and Sleep Research, Department of Medical Sciences, Uppsala University, Uppsala, Sweden.
| | - Jan Hedner
- Center for Sleep and Wake Disorders, Institute of Medicine, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden; Pulmonary Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden.
| |
Collapse
|
2
|
Vidal C, Bertelli F, Mallet JP, Gilson R, Borel JC, Gagnadoux F, Bourdin A, Molinari N, Jaffuel D. Mask side-effects are related to gender in long-term CPAP: results from the InterfaceVent real-life study. Respir Res 2024; 25:331. [PMID: 39243031 PMCID: PMC11380403 DOI: 10.1186/s12931-024-02965-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2024] [Accepted: 08/31/2024] [Indexed: 09/09/2024] Open
Abstract
BACKGROUND Over the past three decades, our understanding of sleep apnea in women has advanced, revealing disparities in pathophysiology, diagnosis, and treatment compared to men. However, no real-life study to date has explored the relationship between mask-related side effects (MRSEs) and gender in the context of long-term CPAP. METHODS The InterfaceVent-CPAP study is a prospective real-life cross-sectional study conducted in an apneic adult cohort undergoing at least 3 months of CPAP with unrestricted mask-access (34 different masks, no gender specific mask series). MRSE were assessed by the patient using visual analog scales (VAS). CPAP-non-adherence was defined as a mean CPAP-usage of less than 4 h per day. The primary objective of this ancillary study was to investigate the impact of gender on the prevalence of MRSEs reported by the patient. Secondary analyses assessed the impact of MRSEs on CPAP-usage and CPAP-non-adherence depending on the gender. RESULTS A total of 1484 patients treated for a median duration of 4.4 years (IQ25-75: 2.0-9.7) were included in the cohort, with women accounting for 27.8%. The prevalence of patient-reported mask injury, defined as a VAS score ≥ 5 (p = 0.021), was higher in women than in men (9.6% versus 5.3%). For nasal pillow masks, the median MRSE VAS score for dry mouth was higher in women (p = 0.039). For oronasal masks, the median MRSE VAS score for runny nose was higher in men (p = 0.039). Multivariable regression analyses revealed that, for both women and men, dry mouth was independently and negatively associated with CPAP-usage, and positively associated with CPAP-non-adherence. CONCLUSION In real-life patients treated with long-term CPAP, there are gender differences in patient reported MRSEs. In the context of personalized medicine, these results suggest that the design of future masks should consider these gender differences if masks specifically for women are developed. However, only dry mouth, a side effect not related to mask design, impacts CPAP-usage and non-adherence. TRIAL REGISTRATION INTERFACEVENT IS REGISTERED WITH CLINICALTRIALS.GOV (NCT03013283).FIRST REGISTRATION DATE IS 2016-12-23.
Collapse
Affiliation(s)
- Celia Vidal
- IDESP, INSERM, PreMEdical INRIA, CHU Montpellier, Montpellier University, Montpellier, France
- Groupe Adène, Montpellier, France
| | | | - Jean-Pierre Mallet
- Groupe Adène, Montpellier, France
- Department of Respiratory Diseases, Arnaud de Villeneuve Hospital, CHRU Montpellier, Montpellier University Hospital, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France
- PhyMedExp (INSERM U 1046, CNRS UMR9214), Montpellier University, Montpellier, France
| | | | | | - Frédéric Gagnadoux
- Departement of Respiratory and Sleep Medicine, University Hospital of Angers, Angers, France
| | - Arnaud Bourdin
- Groupe Adène, Montpellier, France
- Department of Respiratory Diseases, Arnaud de Villeneuve Hospital, CHRU Montpellier, Montpellier University Hospital, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France
- PhyMedExp (INSERM U 1046, CNRS UMR9214), Montpellier University, Montpellier, France
| | - Nicolas Molinari
- IDESP, INSERM, PreMEdical INRIA, CHU Montpellier, Montpellier University, Montpellier, France
- Groupe Adène, Montpellier, France
| | - Dany Jaffuel
- Groupe Adène, Montpellier, France.
- Department of Respiratory Diseases, Arnaud de Villeneuve Hospital, CHRU Montpellier, Montpellier University Hospital, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France.
- PhyMedExp (INSERM U 1046, CNRS UMR9214), Montpellier University, Montpellier, France.
| |
Collapse
|
3
|
Tankéré P, Georges M, Abdulmalak C, Schenesse D, Beltramo G, Berrier A, Bonniaud P, Rabec C. Residual upper airway obstruction during nocturnal noninvasive ventilation despite high positive expiratory pressure. Impact of oronasal mask to nasal mask switch. Respir Med Res 2024; 85:101083. [PMID: 38232657 DOI: 10.1016/j.resmer.2023.101083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 12/08/2023] [Accepted: 12/15/2023] [Indexed: 01/19/2024]
Abstract
BACKGROUND Nasal mask (NM) and oronasal masks (OM) can be used to provide noninvasive ventilation (NIV). Recent studies suggested that OM is the most used interface and that there is no difference in efficacy or in tolerance between OM and NM for chronic use. However, studies focusing on video laryngoscopy underlined the impact of OM in residual upper airway obstruction (UAO) under NIV. We sought to assess the real-life practice of switching from OM to NM when UAO events persist despite high EPAP levels. METHODS In an open-label single center prospective cohort study, data from files and full night polysomnography on NM and OM were collected for patients wearing OM and presenting an UAO index ≥15/h despite an EPAP level ≥ 10 cmH20. RESULTS Forty-four patients were included in the study. In 31 patients (74 %), switching to a NM reduced UAOi to ≥10/h. Interestingly, 92 % of these patients still had NM at 3 to 12 months of follow-up. Switching to a NM was also associated with a trend in paCO2 reduction and significant improvements in Epworth, sleep quality and NIV compliance. Successful interface switching was significantly associated with female gender, and a trend was observed in non-smokers. CONCLUSION As for CPAP, switching to a NM improved NIV efficacy in a selected group of patients presenting residual UAO events despite high EPAP levels. Additionally, this switch has an impact on compliance and subjective sleepiness. Thus, in patients with persisting UAO on OM, switching to a NM could be a first-line intervention before considering further investigation such as polygraphy or video laryngoscopy. We also derive an algorithm for mask allocation and adaptation in acute and chronic NIV use.
Collapse
Affiliation(s)
- Pierre Tankéré
- Dept of Pneumology and Intensive Care Unit, Reference Centre for Rare Lung Diseases, Dijon University Hospital, Dijon, France
| | - Marjolaine Georges
- Dept of Pneumology and Intensive Care Unit, Reference Centre for Rare Lung Diseases, Dijon University Hospital, Dijon, France; University of Bourgogne Franche-Comté, Dijon, France; Centre des Sciences du Goût et de l'Alimentation, INRA, UMR 6265 CNRS 1234, University of Bourgogne Franche-Comté, Dijon, France
| | - Caroline Abdulmalak
- Department of Intensive Care Medicine, William Morey General Hospital, Chalon-Sur-Saône, France
| | - Deborah Schenesse
- Dept of Pneumology and Intensive Care Unit, Reference Centre for Rare Lung Diseases, Dijon University Hospital, Dijon, France
| | - Guillaume Beltramo
- Dept of Pneumology and Intensive Care Unit, Reference Centre for Rare Lung Diseases, Dijon University Hospital, Dijon, France; University of Bourgogne Franche-Comté, Dijon, France; INSERM, LNC UMR1231, LipSTIC LabEx Team, Dijon, France
| | - Amaury Berrier
- Dept of Pneumology and Intensive Care Unit, Reference Centre for Rare Lung Diseases, Dijon University Hospital, Dijon, France
| | - Philippe Bonniaud
- Dept of Pneumology and Intensive Care Unit, Reference Centre for Rare Lung Diseases, Dijon University Hospital, Dijon, France; University of Bourgogne Franche-Comté, Dijon, France; INSERM, LNC UMR1231, LipSTIC LabEx Team, Dijon, France
| | - Claudio Rabec
- Dept of Pneumology and Intensive Care Unit, Reference Centre for Rare Lung Diseases, Dijon University Hospital, Dijon, France.
| |
Collapse
|
4
|
Franke C, Piezonna F, Schäfer R, Grimm A, Loris LM, Schwaibold M. Effect of a digital patient motivation and support tool on CPAP/APAP adherence and daytime sleepiness: a randomized controlled trial. Sleep Biol Rhythms 2024; 22:49-63. [PMID: 38469583 PMCID: PMC10899947 DOI: 10.1007/s41105-023-00479-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 07/22/2023] [Indexed: 03/13/2024]
Abstract
The purpose of this study was to assess the effect of a digital patient support (DPS) tool, complementary to standard care on continuous or automatic positive airway pressure (auto)CPAP adherence and daytime sleepiness after 12 weeks in patients diagnosed with severe obstructive sleep apnea (OSA). All patients with apnea-hypopnea index (AHI) ≥ 30 per hour were prospectively included and randomized to receive standard care (SC) or standard care with personalized DPS via a mobile app prototype version (SC + DPS). Patients in the SC + DPS arm received additionally automated feedback on their therapy, motivational messages and therapy recommendations. 100 patients completed the study (SC: 50, SC + DPS: 50). No differences were found in characteristics of SC vs. SC + DPS (mean ± SD) for age (53.9 ± 10.8 vs. 51.7 ± 12.3 years), initial diagnostic apnea-hypopnea index (51.1 ± 15.5 vs. 50.9 ± 17.7 events/h), BMI (33.8 ± 6.7 vs. 33.5 ± 4.5 kg/m), and Epworth Sleepiness Scale (ESS) baseline score (9.5 ± 4.2 vs. 9.1 ± 5.2). After 12 weeks, mean ESS score was significantly lower (SC: 7.6 ± 4.1 vs. SC + DPS: 5.5 ± 3.9; p = 0.006) in the SC + DPS group vs. standard care group. Therapy adherence was significantly higher (SC: 268.7 ± 122.1 vs. SC + DPS: 338.8 ± 106.8 min; p = 0.002) in the SC + DPS group compared to standard care group. No difference was found in the residual AHI between both groups. However, SC + DPS group showed a trend towards fewer phases with increased leakage compared to SC group. Intention-to-treat analysis (112 (56/56) patients) showed similar results. After 12 weeks, (auto)CPAP adherence and daytime sleepiness improved significantly in patients with severe OSA using the digital patient support tool. Clinical Trial Registration (retrospectively registered): Registry: NCT05440279; Title: Effects of Telemedical Support on Therapeutic Results of CPAP Patients; URL: https://clinicaltrials.gov/ct2/show/NCT05440279; Date of registration: June 30, 2022. Supplementary Information The online version contains supplementary material available at 10.1007/s41105-023-00479-9.
Collapse
Affiliation(s)
- Christian Franke
- Medizinisches Versorgungszentrum GbR Sonneberg, 96515 Sonneberg, Germany
| | - Franziska Piezonna
- Medizinisches Versorgungszentrum GbR Sonneberg, 96515 Sonneberg, Germany
| | - Regina Schäfer
- Loewenstein Medical Technology GmbH+Co. KG, 76135 Karlsruhe, Germany
| | - Alexander Grimm
- Loewenstein Medical Technology GmbH+Co. KG, 76135 Karlsruhe, Germany
| | - Lisa-Marie Loris
- Loewenstein Medical Technology GmbH+Co. KG, 76135 Karlsruhe, Germany
| | | |
Collapse
|
5
|
Blanco M, Ernst G, Rabino A, Salvado A, Borsini EE. Performance of the NOSE Questionnaire in Mask Selection for Home CPAP Titration. Sleep Sci 2023; 16:e425-e429. [PMID: 38197029 PMCID: PMC10773520 DOI: 10.1055/s-0043-1776769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 01/31/2023] [Indexed: 01/11/2024] Open
Abstract
Introduction Many patients abandon CPAP treatment because they find the mask uncomfortable. Therefore, specialists may benefit from the predictive value of airway assessment tools. Objective To identify nasal ventilation failure through the Nasal Obstruction Symptom Evaluation (NOSE) scale in patients with obstructive sleep apnea (OSA) who undergo home-based auto-adjusting CPAP titration and to determine whether there is a correlation between NOSE score and the type of mask selected. Materials and Methods In this prospective correlational study, the NOSE scale was used in terms of mask selection and titration indicators. Patients were classified based on their NOSE score: > or < 50. Results We included 303 patients; 226 men (74.5%), BMI: 33.2 ± 6.1 kg/m 2 , neck circumference (cm): 42.8 ± 3.6 and Epworth (ESS) score: 9.2 ± 5.6, mild OSA: 12 (3.9%), moderate OSA: 127 (41.9%), and severe OSA: 164 (54.1%). The mean NOSE score was 24.3 ± 22.8 and 42 patients (13.8%) had NOSE scores > 50. Indicators for both groups were: compliance (5.9 ± 1.3 vs. 5.8 ± 1.4 hours) p: 0.41, therapeutic pressure (9.1 ± 2.0 vs. 8.8 ± 1.6 cm of H 2 O) p: 0.23, residual AHI (2.3 ± 1.8 vs. 2.8 ± 2.6 events/hour) p: 0.25, and leaks (20.5 ± 10.6 vs. 21.3 ± 10.7 liters/minute) p: 0.64. According to adjusted multiple regression, a NOSE of > 50 was not a predictor of mask selection. Conclusions A > 50 NOSE score was not a predictor of mask selection, and it was not correlated to titration performance.
Collapse
Affiliation(s)
- Magalí Blanco
- Sleep and Ventilation Unit, Hospital Britanico, Buenos Aires, Buenos Aires City, Argentina
| | - Glenda Ernst
- Sleep and Ventilation Unit, Hospital Britanico, Buenos Aires, Buenos Aires City, Argentina
| | - Alberto Rabino
- Otorhinolaryngology Department, Hospital Britanico, Buenos Aires, Buenos Aires City, Argentina
| | - Alejandro Salvado
- Sleep and Ventilation Unit, Hospital Britanico, Buenos Aires, Buenos Aires City, Argentina
| | | |
Collapse
|
6
|
Deng B, Lai F, Zhang M, Xiong C, Chen F, Zhang H, Ma Y, Zhou D. Nasal pillow vs. standard nasal mask for treatment of OSA: a systematic review and meta-analysis. Sleep Breath 2023; 27:1217-1226. [PMID: 36214944 DOI: 10.1007/s11325-022-02721-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 09/23/2022] [Accepted: 09/30/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE The purpose of this study was to compare the effectiveness of nasal pillows with standard nasal masks in the treatment of patients with obstructive sleep apnea (OSA). METHODS A digitalized search was carried out in four different databases including PubMed, Scopus, EMBASE, and CENTRAL using relevant keywords along with a manual search in relevant journals. All comparative studies comparing outcomes of using a nasal pillow with the use of standard nasal masks for continuous positive airway pressure (CPAP) treatment in patients with OSA were included. The qualitative analysis was carried out by tabulating the demographic data. The quantitative data were subjected to meta-analysis. The quality of comparative studies (both retrospective and prospective cohorts) was evaluated using New-castle Ottawa scale (NOS). RESULTS A total of 14 studies (eight prospective and six retrospective) were included in the review. Of them, five studies were randomized and were of cross-over study design. No significant differences were observed in achieved CPAP and residual apnea-hypopnea index (AHI) levels between the nasal pillow and nasal mask with SMD - 0.05 95% CI [- 0.18, 0.09], p = 0.50 and SMD - 0.13 95% CI [- 0.28, 0.03], p = 0.12, respectively. However, nasal pillow usage was associated with better CPAP adherence with a difference of only + 0.29 min/night as compared to a standard nasal mask, with SMD 0.29 95% CI [0.07, 0.50], p = 0.009. CONCLUSION Nasal pillow and standard nasal mask were equally effective in terms of residual AHI level and achieved similar therapeutic CPAP pressures. However, the difference in CPAP adherence between groups, though statistically significant, is of questionable clinical significance.
Collapse
Affiliation(s)
- Bo Deng
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Fei Lai
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Manman Zhang
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Chenyili Xiong
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Feng Chen
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Heng Zhang
- Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China.
| | - Yuanyuan Ma
- Department of Orthopedics, Chengdu Longquanyi First People's Hospital, Chengdu, China
| | - Daiying Zhou
- Department of Orthopedics, Chengdu Longquanyi First People's Hospital, Chengdu, China
| |
Collapse
|
7
|
Tinoco HA, Perdomo-Hurtado L, Henao-Cruz JA, Escobar-Serna JF, Jaramillo-Robledo O, Aguirre-Ospina OD, Hurtado-Hernández M, Lopez-Guzman J. Evaluation and Performance of a Positive Airway Pressure Device (CPAP-AirFlife™): A Randomized Crossover Non-Inferiority Clinical Study in Normal Subjects. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1372. [PMID: 37629662 PMCID: PMC10456951 DOI: 10.3390/medicina59081372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/21/2023] [Accepted: 07/21/2023] [Indexed: 08/27/2023]
Abstract
Background and Objectives: During the COVID-19, the demand for non-invasive ventilatory support equipment significantly increased. In response, a novel non-invasive ventilatory support model called CPAP-AirFlife™ was developed utilizing existing technologies. This model offers technological advantages, including an aerosol-controlled helmet suitable for high-risk environments such as ambulances. Additionally, it is cost-effective and does not require medical air, making it accessible for implementation in low-level hospitals, particularly in rural areas. This study aimed to assess the efficacy of CPAP-AirFlife™ by conducting a non-inferiority comparison with conventional ventilation equipment used in the Intensive Care Unit. Materials and Methods: A clinical study was conducted on normal subjects in a randomized and sequential manner. Parameters such as hemoglobin oxygen saturation by pulse oximetry, exhaled PCO2 levels, vital signs, and individual tolerance were compared between the CPAP-AirFlife™ and conventional equipment. The study population was described in terms of demographic characteristics and included in the analysis. Results: It was shown that the CPAP-AirFlife™ was not inferior to conventional equipment in terms of efficacy or tolerability. Hemoglobin oxygen saturation levels, exhaled PCO2 levels, vital signs, and individual tolerance did not significantly differ between the two models. Conclusions: The findings suggest that CPAP-AirFlife™ is a practical and cost-effective alternative for non-invasive ventilatory support. Its technological advantages, including the aerosol-controlled helmet, make it suitable for high-risk environments. The device's accessibility and affordability make it a promising solution for implementation in low-level hospitals, particularly in rural areas. This study supports using CPAP-AirFlife™ as a practical option for non-invasive ventilatory support, providing a valuable contribution to respiratory care during the COVID-19 pandemic and beyond.
Collapse
Affiliation(s)
- Héctor A. Tinoco
- Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Fundadores, Manizales-Caldas 170001, Colombia
| | - Luis Perdomo-Hurtado
- Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Fundadores, Manizales-Caldas 170001, Colombia
| | | | | | | | | | - Mateo Hurtado-Hernández
- Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Fundadores, Manizales-Caldas 170001, Colombia
| | - Juliana Lopez-Guzman
- Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Fundadores, Manizales-Caldas 170001, Colombia
| |
Collapse
|
8
|
Chang JL, Goldberg AN, Alt JA, Alzoubaidi M, Ashbrook L, Auckley D, Ayappa I, Bakhtiar H, Barrera JE, Bartley BL, Billings ME, Boon MS, Bosschieter P, Braverman I, Brodie K, Cabrera-Muffly C, Caesar R, Cahali MB, Cai Y, Cao M, Capasso R, Caples SM, Chahine LM, Chang CP, Chang KW, Chaudhary N, Cheong CSJ, Chowdhuri S, Cistulli PA, Claman D, Collen J, Coughlin KC, Creamer J, Davis EM, Dupuy-McCauley KL, Durr ML, Dutt M, Ali ME, Elkassabany NM, Epstein LJ, Fiala JA, Freedman N, Gill K, Boyd Gillespie M, Golisch L, Gooneratne N, Gottlieb DJ, Green KK, Gulati A, Gurubhagavatula I, Hayward N, Hoff PT, Hoffmann OM, Holfinger SJ, Hsia J, Huntley C, Huoh KC, Huyett P, Inala S, Ishman SL, Jella TK, Jobanputra AM, Johnson AP, Junna MR, Kado JT, Kaffenberger TM, Kapur VK, Kezirian EJ, Khan M, Kirsch DB, Kominsky A, Kryger M, Krystal AD, Kushida CA, Kuzniar TJ, Lam DJ, Lettieri CJ, Lim DC, Lin HC, Liu SY, MacKay SG, Magalang UJ, Malhotra A, Mansukhani MP, Maurer JT, May AM, Mitchell RB, Mokhlesi B, Mullins AE, Nada EM, Naik S, Nokes B, Olson MD, Pack AI, Pang EB, Pang KP, Patil SP, Van de Perck E, Piccirillo JF, Pien GW, Piper AJ, Plawecki A, Quigg M, Ravesloot MJ, Redline S, Rotenberg BW, Ryden A, Sarmiento KF, Sbeih F, Schell AE, Schmickl CN, Schotland HM, Schwab RJ, Seo J, Shah N, Shelgikar AV, Shochat I, Soose RJ, Steele TO, Stephens E, Stepnowsky C, Strohl KP, Sutherland K, Suurna MV, Thaler E, Thapa S, Vanderveken OM, de Vries N, Weaver EM, Weir ID, Wolfe LF, Tucker Woodson B, Won CH, Xu J, Yalamanchi P, Yaremchuk K, Yeghiazarians Y, Yu JL, Zeidler M, Rosen IM. International Consensus Statement on Obstructive Sleep Apnea. Int Forum Allergy Rhinol 2023; 13:1061-1482. [PMID: 36068685 PMCID: PMC10359192 DOI: 10.1002/alr.23079] [Citation(s) in RCA: 76] [Impact Index Per Article: 76.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 08/12/2022] [Accepted: 08/18/2022] [Indexed: 11/08/2022]
Abstract
BACKGROUND Evaluation and interpretation of the literature on obstructive sleep apnea (OSA) allows for consolidation and determination of the key factors important for clinical management of the adult OSA patient. Toward this goal, an international collaborative of multidisciplinary experts in sleep apnea evaluation and treatment have produced the International Consensus statement on Obstructive Sleep Apnea (ICS:OSA). METHODS Using previously defined methodology, focal topics in OSA were assigned as literature review (LR), evidence-based review (EBR), or evidence-based review with recommendations (EBR-R) formats. Each topic incorporated the available and relevant evidence which was summarized and graded on study quality. Each topic and section underwent iterative review and the ICS:OSA was created and reviewed by all authors for consensus. RESULTS The ICS:OSA addresses OSA syndrome definitions, pathophysiology, epidemiology, risk factors for disease, screening methods, diagnostic testing types, multiple treatment modalities, and effects of OSA treatment on multiple OSA-associated comorbidities. Specific focus on outcomes with positive airway pressure (PAP) and surgical treatments were evaluated. CONCLUSION This review of the literature consolidates the available knowledge and identifies the limitations of the current evidence on OSA. This effort aims to create a resource for OSA evidence-based practice and identify future research needs. Knowledge gaps and research opportunities include improving the metrics of OSA disease, determining the optimal OSA screening paradigms, developing strategies for PAP adherence and longitudinal care, enhancing selection of PAP alternatives and surgery, understanding health risk outcomes, and translating evidence into individualized approaches to therapy.
Collapse
Affiliation(s)
- Jolie L. Chang
- University of California, San Francisco, California, USA
| | | | | | | | - Liza Ashbrook
- University of California, San Francisco, California, USA
| | | | - Indu Ayappa
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | | | | | - Maurits S. Boon
- Sidney Kimmel Medical Center at Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Pien Bosschieter
- Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Itzhak Braverman
- Hillel Yaffe Medical Center, Hadera Technion, Faculty of Medicine, Hadera, Israel
| | - Kara Brodie
- University of California, San Francisco, California, USA
| | | | - Ray Caesar
- Stone Oak Orthodontics, San Antonio, Texas, USA
| | | | - Yi Cai
- University of California, San Francisco, California, USA
| | | | | | | | | | | | | | | | | | - Susmita Chowdhuri
- Wayne State University and John D. Dingell VA Medical Center, Detroit, Michigan, USA
| | - Peter A. Cistulli
- Faculty of Medicine and Health, University of Sydney, Sydney, Australia
| | - David Claman
- University of California, San Francisco, California, USA
| | - Jacob Collen
- Uniformed Services University, Bethesda, Maryland, USA
| | | | | | - Eric M. Davis
- University of Virginia, Charlottesville, Virginia, USA
| | | | | | - Mohan Dutt
- University of Michigan, Ann Arbor, Michigan, USA
| | - Mazen El Ali
- University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | | | | | | | - Kirat Gill
- Stanford University, Palo Alto, California, USA
| | | | - Lea Golisch
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | | | | | | | - Arushi Gulati
- University of California, San Francisco, California, USA
| | | | | | - Paul T. Hoff
- University of Michigan, Ann Arbor, Michigan, USA
| | - Oliver M.G. Hoffmann
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | | | - Jennifer Hsia
- University of Minnesota, Minneapolis, Minnesota, USA
| | - Colin Huntley
- Sidney Kimmel Medical Center at Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | | | | | - Sanjana Inala
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | | | | | | | | | | | | | | | - Meena Khan
- Ohio State University, Columbus, Ohio, USA
| | | | - Alan Kominsky
- Cleveland Clinic Head and Neck Institute, Cleveland, Ohio, USA
| | - Meir Kryger
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | | | | | - Derek J. Lam
- Oregon Health and Science University, Portland, Oregon, USA
| | | | | | | | | | | | | | - Atul Malhotra
- University of California, San Diego, California, USA
| | | | - Joachim T. Maurer
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | - Anna M. May
- Case Western Reserve University, Cleveland, Ohio, USA
| | - Ron B. Mitchell
- University of Texas, Southwestern and Children’s Medical Center Dallas, Texas, USA
| | | | | | | | | | - Brandon Nokes
- University of California, San Diego, California, USA
| | | | - Allan I. Pack
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | | | | | | - Mark Quigg
- University of Virginia, Charlottesville, Virginia, USA
| | | | - Susan Redline
- Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | | | - Armand Ryden
- Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, California, USA
| | | | - Firas Sbeih
- Cleveland Clinic Head and Neck Institute, Cleveland, Ohio, USA
| | | | | | | | | | - Jiyeon Seo
- University of California, Los Angeles, California, USA
| | - Neomi Shah
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | - Ryan J. Soose
- University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | - Erika Stephens
- University of California, San Francisco, California, USA
| | | | | | | | | | - Erica Thaler
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Sritika Thapa
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | - Nico de Vries
- Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | | | - Ian D. Weir
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | | | | | - Josie Xu
- University of Toronto, Ontario, Canada
| | | | | | | | | | | | - Ilene M. Rosen
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
9
|
Karagiannis A, Tzitiridou M, Kafkia T, Kourakos M. Monitoring Seasonal Compliance of Patients with Obstructive Sleep Apnea Using CPAP Systems via SD Card. Acta Inform Med 2023; 31:96-101. [PMID: 37711489 PMCID: PMC10498369 DOI: 10.5455/aim.2023.31.96-101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 06/22/2023] [Indexed: 09/16/2023] Open
Abstract
Background Obstructive sleep apnea (OSA) is a common disorder characterized by recurrent upper airway collapse during sleep, leading to neurological and cardiovascular adverse effects. Objective The present study aimed to explore seasonal compliance with Continuous Positive Airway Pressure (CPAP) therapy among OSA patients in Greece. Methods Data from 954 OSA patients using CPAP devices were collected during summer and winter months. Factors evaluated included the Apnea-Hypopnea Index (AHI), mask type, mask leaks, and hours of CPAP device usage. Results The majority of patients were male (78.2%) and aged 60 years or above (58.5%). Most patients had been using CPAP for over 2 years (82.8%), with auto CPAP devices and nasal or pillow masks being most common. Compliance was observed in 57.7% of patients, while 22.1% were non-compliant. A significant number of patients (8.2% and 12%) were compliant only in summer or winter, respectively. Compliance was influenced by duration of CPAP use, BMI up to 25, and the use of nasal/pillow masks. Higher compliance was associated with lower summer severity and both low and severe winter severity. Logistic regression analysis confirmed these findings. Conclusion The findings suggest that utilizing CPAP device data can provide actionable insights on seasonal compliance among OSA patients. Summer compliance is lower, and the use of nasal/pillow masks and auto CPAP devices is recommended for improved compliance.
Collapse
Affiliation(s)
| | - Maria Tzitiridou
- Faculty of Midwifery, University of Western Macedonia, Ptolemaida, Greece
| | - Theodora Kafkia
- Faculty of Nursing, International Hellenic University, Thessaloniki, Greece
| | | |
Collapse
|
10
|
Ji KH. Unexpected Resolution of Obstructive Sleep Apnea after Nasal Surgery in a Patient Nonadherent to Continuous Positive Airway Pressure Therapy. Sleep Sci 2023; 16:127-130. [PMID: 37151766 PMCID: PMC10157802 DOI: 10.1055/s-0043-1767758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 05/31/2022] [Indexed: 05/09/2023] Open
Abstract
Continuous positive airway pressure (CPAP) is recommended as first-line therapy in cases of moderate-to-severe obstructive sleep apnea (OSA). Continuous positive airway pressure (CPAP) prevents upper airway obstruction and abolishes apnea or hypopnea events during sleep. But up to 50% of OSA patients may be nonadherent to CPAP due to various causes, including nasal obstruction. Nasal surgery may improve CPAP compliance in some OSA patients but is not regarded as OSA therapy. Here, I report a patient non-adherent to CPAP whose sleep apnea resolved unexpectedly after nasal surgery to increase adherence to CPAP.
Collapse
Affiliation(s)
- Ki-Hwan Ji
- Busan Paik Hospital, Inje University College of Medicine, Department of Neurology, Busan, South Korea
- Address for correspondence Ki-Hwan Ji
| |
Collapse
|
11
|
Palot A, Nguyên XL, Launois S, Prigent A, Graml A, Aversenq E, Koltes C, Recart D, Lavergne F. Effect of switching from continuous to bilevel positive airway pressure on sleep quality in patients with obstructive sleep apnea: the prospective POP IN VAuto study. J Thorac Dis 2023; 15:918-927. [PMID: 36910096 PMCID: PMC9992565 DOI: 10.21037/jtd-22-825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 12/02/2022] [Indexed: 03/05/2023]
Abstract
Background Issues with tolerability and side effects can decrease continuous positive airway pressure (CPAP) device usage and the benefits of therapy. Different positive airway pressure (PAP) therapy modes providing expiratory pressure relief or using a different pressure during inspiration vs. expiration (bilevel PAP) may alleviate some of these issues. This multicenter, prospective study evaluated the effects of switching from CPAP to bilevel PAP (VAuto mode) on respiratory parameters, device usage, side effects and patient-reported outcomes in patients with obstructive sleep apnea (OSA). Methods Eligible OSA patients had started CPAP ≥3 months previously, had good compliance (mean 6.1±2.0 h/night) and well-controlled OSA [residual apnea-hypopnea index (AHI) 4.9±3.1/h] but had pressure tolerance issues or persistent side effects/discomfort. All were switched from CPAP to bilevel PAP (AirCurve 10 VAuto; ResMed). Effectiveness (residual AHI), sleep quality, daytime sleepiness, fatigue, therapy-related side effects, and patient satisfaction/preference were assessed after 3 months and 1 year. Results Forty patients were analyzed (68% male, age 64±11 years, body mass index 30.7±5.8 kg/m2). At 3 months and 1 year after switching to bilevel PAP, median [interquartile range] residual AHI was 4/h [2-5.3] and 3.7/h [1.8-5], respectively, and device usage was 7.0 [4.9-7.5] and 6.4 [4.4-7.3] h/night, respectively. Device switch was associated with significant reductions from baseline in expiratory PAP {from 12 [11-13] to 8 [7-9] cmH2O at 3 months (P<0.001) and 9 [8-12] cmH2O at 1 year (P=0.005)}, 95th percentile pressure {from 14 [12-14] to 10 [9-11] and 10 [8-11] cmH2O; P<0.001 and P=0.001, respectively} and leak {from 1 [0-6] to 0 [0-1] and 0 [0-2] L/min; P=0.049 and P=0.033, respectively}. The Pittsburgh Sleep Quality Index score decreased significantly from baseline to 3 and 6 months [7.2±4.0 to 5.0±3.2 (P=0.005) and 4.5±2.7 (P<0.001), respectively]. CPAP-related mouth dryness, choking sensation and aerophagia were significantly improved one year after switching to bilevel PAP. Bilevel PAP was preferred over CPAP by 90% of patients. Conclusions Switching to bilevel PAP had several benefits in patients struggling with CPAP, facilitating therapy acceptance and ongoing device usage.
Collapse
|
12
|
Rossetto A, Midelet A, Baillieul S, Tamisier R, Borel JC, Prigent A, Bailly S, Pépin JL. Factors Associated With Residual Apnea-Hypopnea Index Variability During CPAP Treatment. Chest 2023; 163:1258-1265. [PMID: 36642368 DOI: 10.1016/j.chest.2022.12.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 12/12/2022] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND CPAP is the first-line therapy for OSA. A high or variable residual apnea-hypopnea index (rAHI) reflects treatment failure and potentially is triggered by exacerbation of cardiovascular comorbidities. Previous studies showed that high rAHI and large rAHI variability are associated with underlying comorbidities, OSA characteristics at diagnosis, and CPAP equipment, including mask type and settings. RESEARCH QUESTION What factors are associated with predefined groups with low to high rAHI variability? STUDY DESIGN AND METHODS This registry-based study included patients with a diagnosis of OSA who were receiving CPAP treatment with at least 90 days of CPAP remote monitoring. We applied the hidden Markov model to analyze the day-to-day trajectories of rAHI variability using telemonitoring data. An ordinal logistic regression analysis identified factors associated with a risk of having a higher and more variable rAHI with CPAP treatment. RESULTS The 1,126 included patients were middle-aged (median age, 66 years; interquartile range [IQR], 57-73 years), predominantly male (n = 791 [70.3%]), and obese (median BMI, 30.6 kg/m2 (IQR, 26.8-35.2 kg/m2). Three distinct groups of rAHI trajectories were identified using hidden Markov modeling: low rAHI variability (n = 393 [35%]), moderate rAHI variability group (n = 420 [37%]), and high rAHI variability group (n = 313 [28%]). In multivariate analysis, factors associated with high rAHI variability were age, OSA severity at diagnosis, heart failure, opioids and alcohol consumption, mental and behavioral disorders, transient ischemic attack and stroke, an oronasal mask, and level of leaks when using CPAP. INTERPRETATION Identifying phenotypic traits and factors associated with high rAHI variability will allow early intervention and the development of personalized follow-up pathways for CPAP treatment.
Collapse
Affiliation(s)
- Anaïs Rossetto
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France
| | - Alphanie Midelet
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France; Probayes, Montbonnot-Saint-Martin, France
| | - Sébastien Baillieul
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France; Service Universitaire de Pneumologie Physiologie, CHU Grenoble Alpes, Grenoble, France
| | - Renaud Tamisier
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France; Service Universitaire de Pneumologie Physiologie, CHU Grenoble Alpes, Grenoble, France
| | - Jean-Christian Borel
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France; AGIR à dom. HomeCare Charity, Meylan, France
| | - Arnaud Prigent
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France; Groupe Medical de Pneumologie, Polyclinique Saint-Laurent, Rennes, France
| | - Sébastien Bailly
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France; Service Universitaire de Pneumologie Physiologie, CHU Grenoble Alpes, Grenoble, France
| | - Jean-Louis Pépin
- HP2 Laboratory, Inserm U1300, Université Grenoble Alpes, Grenoble, France; Service Universitaire de Pneumologie Physiologie, CHU Grenoble Alpes, Grenoble, France.
| |
Collapse
|
13
|
Chen L, Chen Y, Hu S, Lin M, Lee P, Chiang AA, Tu Y. In search of a better CPAP interface: A network meta-analysis comparing nasal masks, nasal pillows and oronasal masks. J Sleep Res 2022; 31:e13686. [PMID: 35821391 PMCID: PMC9787466 DOI: 10.1111/jsr.13686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 05/28/2022] [Accepted: 06/17/2022] [Indexed: 12/30/2022]
Abstract
Until now, no study has directly network meta-analysed the impact of nasal masks, nasal pillows and oronasal masks on continuous positive airway pressure therapy in patients with obstructive sleep apnea. This study aimed to meta-analyse the impact of three kinds of nasal interfaces with both network meta-analysis and pairwise comparison. PubMed, EMBASE, CENTRAL and ClinicalTrials.gov were systematically searched from inception to December 2020 for studies that compared the three types of nasal interfaces for treating obstructive sleep apnea with continuous positive airway pressure. The outcomes were residual apnea-hypopnea index, continuous positive airway pressure, and nightly average usage. The network meta-analysis was conducted using multivariate random-effects in a frequentist framework where three interfaces were ranked with the surface under the cumulative ranking probabilities. The pairwise comparison was conducted using random-effects meta-analysis. Twenty-nine articles comprising 6378 participants were included. The pairwise comparison showed both nasal masks and nasal pillows were associated with lower residual apnea-hypopnea index, lower continuous positive airway pressure, and higher continuous positive airway pressure adherence compared with oronasal masks. The surface under the cumulative ranking confirmed that nasal masks were associated with the lowest residual apnea-hypopnea index and highest adherence, while pillows were associated with the lowest continuous positive airway pressure. The meta-regression identified that lower pretreatment apnea-hypopnea index and continuous positive airway pressure determined during continuous positive airway pressure titration (versus determined during continuous positive airway pressure therapy) was associated with lower continuous positive airway pressure with nasal masks and nasal pillows. In conclusion, compared with oronasal masks, nasal masks and nasal pillows are better interfaces, especially in patients with lower pretreatment apnea-hypopnea index and those with the therapeutic pressure determined during continuous positive airway pressure titration.
Collapse
Affiliation(s)
- Li‐Yang Chen
- Department of Internal MedicineTainan Sin Lau HospitalTainanTaiwan
| | - Yung‐Hsuan Chen
- Center of Sleep DisorderNational Taiwan University HospitalTaipeiTaiwan,Department of Internal MedicineNational Taiwan University HospitalTaipeiTaiwan
| | | | - Ming‐Tzer Lin
- Center of Sleep DisorderNational Taiwan University HospitalTaipeiTaiwan,Department of Internal MedicineHsiao Chung‐Cheng HospitalNew TaipeiTaiwan
| | - Pei‐Lin Lee
- Center of Sleep DisorderNational Taiwan University HospitalTaipeiTaiwan,Department of Internal MedicineNational Taiwan University HospitalTaipeiTaiwan,School of MedicineNational Taiwan UniversityTaipeiTaiwan,Center for Electronics Technology Integration, National Taiwan UniversityTaipeiTaiwan
| | - Ambrose A. Chiang
- Division of Sleep Medicine, Louis Stokes VA Medical Center; Department of MedicineCase Western Reserve UniversityClevelandOhioUSA
| | - Yu‐Kang Tu
- Institute of Epidemiology and Preventive Medicine, College of Public Health, National Taiwan UniversityTaipeiTaiwan
| |
Collapse
|
14
|
Clinical Decision-making for Continuous Positive Airway Pressure Mask Selection. Sleep Med Clin 2022; 17:569-576. [DOI: 10.1016/j.jsmc.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
15
|
Genzor S, Prasko J, Vanek J, Asswad AG, Nadjarpour S, Sova M. Adherence of obstructive sleep apnoea syndrome patients to positive airway pressure therapy - 10-year follow-up. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2022; 166:441-446. [PMID: 34282803 DOI: 10.5507/bp.2021.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 06/15/2021] [Indexed: 12/16/2022] Open
Abstract
PURPOSE Continuous positive airway pressure (CPAP) is the most effective therapy for obstructive sleep apnoea syndrome (OSAS). Long-term adherence is necessary; however, it may be widely variable based on current literature, where the predicting factors are also not well defined. The aim of this study was to assess ten-year adherence to CPAP and to define factors influencing it. METHODS In total, 107 patients (91 males) were enrolled in this study, with an average age of 53.5 years (SD 10.1), with CPAP therapy being indicated (Apnoea-Hypopnoea Index - AHI > 15). Anthropometric and social status data have been obtained as well as the average use of CPAP through device memory. RESULTS Sufficient adherence (> 4 h per night) was found in 57% of patients in the first year with no subsequent significant change during the next 9 years. Adherence correlated significantly with the severity of OSAS - AHI (r = 0.321 over 5 years) and Epworth Sleepiness Scale (r = 0.317 over ten years) but did not correlate with the pressure used or the age of the patient. No statistically significant differences have been found between the sexes, the different mask groups, or the social status groups. CONCLUSION Good adherence to CPAP therapy in OSAS patients is essential. According to our results, patients with more severe OSAS or more severe sleepiness seem to have better adherence.
Collapse
Affiliation(s)
- Samuel Genzor
- Department of Respiratory Medicine, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, Czech Republic
| | - Jan Prasko
- Department of Psychiatry, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
| | - Jakub Vanek
- Department of Psychiatry, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
| | - Amjad Ghazal Asswad
- Department of Respiratory Medicine West Middlesex University Hospital, London, United Kingdom of Great Britain and Northern Ireland
| | - Shayan Nadjarpour
- Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, Czech Republic
| | - Milan Sova
- Department of Respiratory Medicine, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, Czech Republic
| |
Collapse
|
16
|
Ahonen H, Broström A, Fransson EI, Neher M, Lindmark U. "The terrible dryness woke me up, I had some trouble breathing"-Critical situations related to oral health as described by CPAP-treated persons with obstructive sleep apnea. J Sleep Res 2022; 31:e13670. [PMID: 35765213 PMCID: PMC10909513 DOI: 10.1111/jsr.13670] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 05/04/2022] [Accepted: 05/24/2022] [Indexed: 11/30/2022]
Abstract
Continuous positive airway pressure is a common and effective treatment for obstructive sleep apnea, but adherence remains an issue. Both obstructive sleep apnea and oral diseases are associated with cardiovascular diseases, and as oral dryness contributes to treatment abandonment, oral health is of importance for this patient group. The aim was therefore to explore how persons with continuous positive airway pressure-treated obstructive sleep apnea experience situations associated with their oral health, and which actions they take to manage these. An explorative and descriptive design was adopted using the critical incident technique. Based on a purposeful selection, 18 adults with long-term experience of continuous positive airway pressure-treatment were interviewed using a semi-structured interview guide. Both negative and positive situations were described. Negative situations consisted of challenges with breathing, including mouth-breathing, choking sensations, problems with night-time and daytime oral dryness, changes in the saliva composition, and deteriorating oral health. Positive situations included experiences of reduced mouth-breathing and oral dryness. The situations were often successfully managed by mimicking daytime movements, changing sleeping position, adjusting the CPAP-device and mask, increasing oral hygiene efforts, drinking water, using a humidifier or chinstrap, or contacting their oral healthcare clinic. Long-term experience of persons with continuous positive airway pressure-treated obstructive sleep apnea regard situations and actions from everyday life. Successful management can contribute to long-term adherence and decrease negative effects on oral health. More interdisciplinary collaborations could enable identification and adequate recommendations for persons who experience negative situations during their continuous positive airway pressure treatment.
Collapse
Affiliation(s)
- Hanna Ahonen
- Centre for Oral Health, School of Health and WelfareJönköping UniversityJönköpingSweden
| | - Anders Broström
- A.D.U.L.T., School of Health and WelfareJönköping UniversityJönköpingSweden
- Department of Clinical NeurophysiologyUniversity Hospital LinköpingLinköpingSweden
| | | | - Margit Neher
- A.D.U.L.T., School of Health and WelfareJönköping UniversityJönköpingSweden
| | - Ulrika Lindmark
- Centre for Oral Health, School of Health and WelfareJönköping UniversityJönköpingSweden
- Department of Health SciencesKarlstad UniversityKarlstadSweden
| |
Collapse
|
17
|
Frange C, Franco AM, Brasil E, Hirata RP, Lino JA, Mortari DM, Ykeda DS, Leocádio-Miguel MA, D’Aurea CVR, Silva LOE, Telles SCL, Furlan SF, Peruchi BB, Leite CF, Yagihara FT, Campos LD, Ulhôa MA, Cruz MGDR, Beidacki R, Santos RB, de Queiroz SS, Barreto S, Piccin VS, Coelho FMS, Studart L, Assis M, Drager LF. Practice recommendations for the role of physiotherapy in the management of sleep disorders: the 2022 Brazilian Sleep Association Guidelines. Sleep Sci 2022; 15:515-573. [PMID: 36419815 PMCID: PMC9670776 DOI: 10.5935/1984-0063.20220083] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 09/19/2022] [Indexed: 08/13/2024] Open
Abstract
This clinical guideline supported by the Brazilian Sleep Association comprises a brief history of the development of Brazilian sleep physiotherapy, outlines the role of the physiotherapist as part of a sleep health team, and describes the clinical guidelines in respect of the management of some sleep disorders by the physiotherapist (including sleep breathing disorders, i.e., obstructive sleep apnea, central sleep apnea, upper airway resistance syndrome, hypoventilation syndromes and overlap syndrome, and pediatric sleep breathing disorders; sleep bruxism; circadian rhythms disturbances; insomnia; and Willis-Ekbom disease/periodic limb movement disorder. This clinical practice guideline reflects the state of the art at the time of publication and will be reviewed and updated as new information becomes available.
Collapse
Affiliation(s)
- Cristina Frange
- Departamento de Neurologia e Neurocirurgia, Escola Paulista de
Medicina (EPM), Universidade Federal de São Paulo (UNIFESP) - São
Paulo - SP - Brazil
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
| | - Aline Marques Franco
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Neurociências e Ciências do
Comportamento, Faculdade de Medicina de Ribeirão Preto, Universidade de
São Paulo (FMRP-USP) - Ribeirão Preto - SP - Brazil
| | - Evelyn Brasil
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Terapia Intensiva, Hospital Israelita Albert
Einstein (HIAE) - São Paulo - SP - Brazil
| | - Raquel Pastrello Hirata
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Laboratório de Pesquisa em Fisioterapia Pulmonar,
Departamento de Fisioterapia, Universidade Estadual de Londrina (UEL) - Londrina -
PR - Brazil
| | - Juliana Arcanjo Lino
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Ciências Médicas, Universidade Federal do
Ceará (UFC) - Fortaleza - CE - Brazil
| | - Daiana Moreira Mortari
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Universidade Federal do Rio Grande do Sul - Porto Alegre - RS -
Brazil
| | - Daisy Satomi Ykeda
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Curso de Fisioterapia, Universidade Estadual do Piauí
(UESPI) - Teresina - PI - Brazil
| | - Mario André Leocádio-Miguel
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Fisiologia e Comportamento, Universidade Federal do
Rio Grande do Norte - Natal - RN - Brazil
| | | | - Luciana Oliveira e Silva
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Ciências da Saúde, Universidade
Federal de Uberlândia (UFU) - Uberlândia - MG - Brazil
| | | | - Sofia Fontanello Furlan
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Unidade de Hipertensão, Instituto do Coração
(InCor), Faculdade de Medicina, Universidade de São Paulo (USP) - São
Paulo - SP - Brazil
| | - Bruno Búrigo Peruchi
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Laboratório de Neurociência, Universidade do Estado
de Santa Catarina (UNESC) - Criciúma - SC - Brazil
| | - Camila Ferreira Leite
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Fisioterapia, UFC; Programas de Mestrado em
Fisioterapia e Funcionalidade, e Mestrado em Ciências Cardiovasculares, UFC -
Fortaleza - CE - Brazil
| | - Fabiana Tokie Yagihara
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Setor de Neurofisiologia Clínica, Departamento de
Neurologia e Neurocirurgia, EPM, UNIFESP - São Paulo - SP - Brazil
| | | | - Melissa Araújo Ulhôa
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Instituto Metropolitano de Ensino Superior, Faculdade de Medicina
do Vale do Aço (UNIVAÇO) - Ipatinga - MG - Brazil
| | | | - Ricardo Beidacki
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Faculdade Inspirar, Unidade Porto Alegre - Porto Alegre - RS -
Brazil
| | - Ronaldo Batista Santos
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Fisioterapia, Hospital Universitário, USP -
São Paulo - Brazil
| | | | - Simone Barreto
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Instituto do Sono, Associação Fundo Incentivo
à Pesquisa - São Paulo - Brazil
| | - Vivien Schmeling Piccin
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Laboratório do Sono, Divisão de Pneumologia do
Instituto do Coração (InCor), FMUSP, USP - São Paulo - SP -
Brazil
| | - Fernando Morgadinho Santos Coelho
- Departamento de Neurologia e Neurocirurgia, Escola Paulista de
Medicina (EPM), Universidade Federal de São Paulo (UNIFESP) - São
Paulo - SP - Brazil
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Departamento de Psicobiologia, EPM, UNIFESP - São Paulo -
SP - Brazil
| | - Luciana Studart
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Universidade Federal de Pernambuco - Recife - PE - Brazil
| | - Marcia Assis
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Clínica do Sono de Curitiba, Hospital São Lucas -
Curitiba - PR - Brazil
| | - Luciano F. Drager
- Associação Brasileira do Sono - São Paulo - SP
- Brazil
- Unidade de Hipertensão, Instituto do Coração
(InCor), Faculdade de Medicina, Universidade de São Paulo (USP) - São
Paulo - SP - Brazil
| |
Collapse
|
18
|
Aghadavoudi O, Beheshtiparvar D, Shafa A. Evaluation of Ventilation with Nasal Versus Face Mask After General Anesthesia Induction in Pediatric Patients. Anesth Pain Med 2022; 12:e123205. [PMID: 36818486 PMCID: PMC9923338 DOI: 10.5812/aapm-123205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 04/10/2022] [Accepted: 07/19/2022] [Indexed: 11/16/2022] Open
Abstract
Background Because of some difficulties during face mask ventilation in unconscious patients, such as upper airway obstruction patients, we conducted this study to compare nasal and face mask ventilation during general anesthesia induction. Methods In this clinical trial study, 70 patients between 3 and 12 years old undergoing elective lower abdominal surgery with general anesthesia were randomly divided into two groups. After administration of induction agents, one group was ventilated with the face mask and 100% oxygenation in three minutes and the other with the nasal mask. The mean expiratory volume, airway pressure, end-tidal CO2 (EtCO2), blood oxygen saturation (SpO2), and hemodynamic factors were recorded and compared in the baseline, two minutes after mask ventilation, and five minutes after intubation. Results The mean EtCO2 in the second minute after ventilation was significantly higher in the nasal mask group than in the face mask group (P = 0.04). However, in the fifth minute after intubation, there was no significant difference between the two groups (P = 0.31). Other factors related to ventilation did not significantly differ between the two groups. Conclusions It can be concluded that nasal mask ventilation is as effective as facial mask ventilation. The nasal mask can replace the face mask if there is difficult face mask ventilation or airway obstruction.
Collapse
Affiliation(s)
- Omid Aghadavoudi
- Department of Anesthesiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | | | - Amir Shafa
- Anesthesiology Department, Isfahan University of Medical Sciences, Isfahan, Iran
- Corresponding Author: Anesthesiology Department, Isfahan University of Medical Sciences, Isfahan, Iran.
| |
Collapse
|
19
|
Telemonitoring for the Follow-Up of Obstructive Sleep Apnea Patients Treated with CPAP: Accuracy and Impact on Therapy. SENSORS 2022; 22:s22072782. [PMID: 35408395 PMCID: PMC9002933 DOI: 10.3390/s22072782] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 03/27/2022] [Accepted: 03/31/2022] [Indexed: 12/28/2022]
Abstract
Continuous positive airway pressure (CPAP) telemonitoring (TMg) has become widely implemented in routine clinical care. Objective measures of CPAP compliance, residual respiratory events, and leaks can be easily monitored, but limitations exist. This review aims to assess the role of TMg in CPAP-treated obstructive sleep apnea (OSA) patients. We report recent data related to the accuracy of parameters measured by CPAP and try to determine the role of TMg in CPAP treatment follow-up, from the perspective of both healthcare professionals and patients. Measurement and accuracy of CPAP-recorded data, clinical management of these data, and impacts of TMg on therapy are reviewed in light of the current literature. Moreover, the crucial questions of who and how to monitor are discussed. TMg is a useful tool to support, fine-tune, adapt, and control both CPAP efficacy and compliance in newly-diagnosed OSA patients. However, clinicians should be aware of the limits of the accuracy of CPAP devices to measure residual respiratory events and leaks and issues such as privacy and cost-effectiveness are still a matter of concern. The best methods to focus our efforts on the patients who need TMg support should be properly defined in future long-term studies.
Collapse
|
20
|
Nasal Symptoms in Patients with Obstructive Sleep Apnoea and Their Association with Continuous Positive Airway Pressure Usage. Life (Basel) 2022; 12:life12020305. [PMID: 35207592 PMCID: PMC8877853 DOI: 10.3390/life12020305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/06/2022] [Accepted: 02/16/2022] [Indexed: 11/24/2022] Open
Abstract
The role of nasal symptoms in continuous positive airway pressure (CPAP) tolerance is not completely clear. This study aimed to investigate the association between CPAP usage and nasal symptoms, either prior to, or developing during, CPAP use in patients with obstructive sleep apnoea (OSA). Two hundred thirty patients were studied and divided into high-, low-, and non-CPAP users. Nasal symptoms and related quality of life parameters were evaluated prior to CPAP initiation and after three months. We also investigated predictive factors for CPAP usage. Non-CPAP users had significantly worse baseline scores for runny nose compared with high and low users (1.34 vs. 0.68 and 0.75, respectively, p = 0.006). There were no other significant differences between the groups. Runny nose was an independent predictive factor for lower CPAP usage (p = 0.036). An evaluation after three months showed worsening in runny nose score in high-CPAP users (p = 0.025) but not in low- and non-users. There were no significant changes in other nasal symptoms. Our study demonstrates that nasal symptoms were very common in this population but rhinorrhoea was the only symptom associated with poorer CPAP adherence. Moreover, rhinorrhoea worsened after a three-month trial of high-CPAP usage.
Collapse
|
21
|
Narang I, Kendzerska T, Heffernan A, Malik U, Carvalho CG, Ryan CM. Positive Airway Pressure Usage in Youth with Obstructive Sleep Apnea Following Transition to Adult Health Care. Nat Sci Sleep 2022; 14:153-163. [PMID: 35140537 PMCID: PMC8818969 DOI: 10.2147/nss.s345143] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 01/14/2022] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND There is increasing prevalence of moderate to severe obstructive sleep apnea (OSA) in adolescents, the majority of whom receive treatment with positive airway pressure (PAP). Adherence to PAP is sub-optimal in adolescents with OSA. Moreover, the impact of transition from pediatric to adult healthcare system on PAP adherence is unknown. This is relevant as the transition period is a time of increased stress for youth with chronic illnesses. RESEARCH QUESTION Does PAP adherence decrease during the 1-year transition period from pediatric to adult healthcare system in those with OSA? STUDY DESIGN AND METHODS Youth previously diagnosed with persistent OSA and treated with PAP in a large academic center (Toronto, Canada) between 2017 and 2019 were enrolled on transfer from the pediatric to adult sleep clinic and followed at 12 months. Mixed-effects linear regression models were used to investigate the effect of time since the transfer on objective PAP adherence with adjustment for confounders. RESULTS Among the 45 enrolled participants, 42.2% were female, the median age was 18 years (interquartile range [IQR]: 17-18), median BMI was 30.3 (IQR: 24.0-37.1), and the median apnea-hypopnea index (AHI) was 17.8 events/hour (11.8-30.7). In univariate analysis, we observed a significant reduction in the 12-month average PAP usage in days used at follow-up compared to PAP use at the time of enrolment: median of 5.0 hours/day (IQR: 1.3-8.0) vs 2.6 hours/day (0.0-6.4), p < 0.0001. Following adjustment for age, level of education, employment status and living arrangement, the 12-month average PAP usage in days remained significantly decreased at follow-up compared to at the time of enrolment: change in hours of -1.14; 95% CI -2.27 to -0.01. INTERPRETATION Among youth with OSA treated with PAP, there is a clinically significant reduction in PAP adherence over the first year during the transition from pediatric to adult health care.
Collapse
Affiliation(s)
- Indra Narang
- Department of Pediatrics, University of Toronto, Toronto, Canada.,The Hospital for Sick Children, Toronto, Canada
| | - Tetyana Kendzerska
- Department of Medicine, Faculty of Medicine, University of Ottawa, Ottawa, Canada.,The Ottawa Hospital Research Institute, Ottawa, Canada
| | | | - Uzair Malik
- RCSI University of Medicine and Health Sciences, Dublin, Ireland
| | | | - Clodagh M Ryan
- Department of Medicine, University of Toronto, Toronto, Canada.,Sleep Research laboratory, KITE-UHN
| |
Collapse
|
22
|
Kang YJ, Cho JH, Park CS. Analysis of risk factors for air leakage in auto-titrating positive airway pressure users: a single-center study. J Clin Sleep Med 2022; 18:75-88. [PMID: 34170231 PMCID: PMC8807919 DOI: 10.5664/jcsm.9504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
STUDY OBJECTIVES Because air leakage from masks is known as a common cause of low adherence to continuous positive airway pressure therapy, we analyzed the risk factors for air leakage related to parameters associated with auto-titrating positive airway pressure, polysomnography, InBody Test, and rhinomanometry. METHODS Usage data and medical records of 120 auto-titrating positive airway pressure users were reviewed retrospectively. All patients used a nasal or pillow mask and were carefully monitored at scheduled follow-ups. RESULTS Use of a pillow mask, sex (male), age, and abdominal fat percentage were significantly associated with high average air leakage. The higher the auto-titrating positive airway pressure average and mean pressure, the more likely patients exhibited high rates of air leakage. The percentage of patients with high average air leakage increased over time (up to 6 months of follow-up). CONCLUSIONS Older male patients using a pillow mask and those with a high abdominal fat percentage and high auto-titrating positive airway pressure may require close follow-up and continuous monitoring for air leakage. Because air leakage from a mask can change over time, mask-sealing capacity should be reassessed and masks should be changed regularly. CITATION Kang YJ, Cho J-H, Park C-S. Analysis of risk factors for air leakage in auto-titrating positive airway pressure users: a single-center study. J Clin Sleep Med. 2022;18(1):75-88.
Collapse
Affiliation(s)
- Yun Jin Kang
- Department of Otolaryngology-Head and Neck Surgery, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, Suwon, Republic of Korea
| | - Jin-Hee Cho
- Department of Otolaryngology-Head and Neck Surgery, Yeouido St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Chan-Soon Park
- Department of Otolaryngology-Head and Neck Surgery, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, Suwon, Republic of Korea,Address correspondence to: Chan-Soon Park, MD, PhD, Department of Otorhinolaryngology-Head and Neck Surgery, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, 93 Jungbu Daero (Ji-dong), Suwon Si, Paldal-gu, Gyeonggi-Do, 16247, Republic of Korea; Tel: +82-31-249-8968; Fax: +82-31-257-3752;
| |
Collapse
|
23
|
Midelet A, Bailly S, Tamisier R, Borel JC, Baillieul S, Le Hy R, Schaeffer MC, Pépin JL. Hidden Markov model segmentation to demarcate trajectories of residual apnoea-hypopnoea index in CPAP-treated sleep apnoea patients to personalize follow-up and prevent treatment failure. EPMA J 2021; 12:535-544. [PMID: 34956425 PMCID: PMC8648940 DOI: 10.1007/s13167-021-00264-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/02/2021] [Indexed: 12/26/2022]
Abstract
BACKGROUND Continuous positive airway pressure (CPAP), the reference treatment for obstructive sleep apnoea (OSA), is used by millions of individuals worldwide with remote telemonitoring providing daily information on CPAP usage and efficacy, a currently underused resource. Here, we aimed to implement data science methods to provide tools for personalizing follow-up and preventing treatment failure. METHODS We analysed telemonitoring data from adults prescribed CPAP treatment. Our primary objective was to use Hidden Markov models (HMMs) to identify the underlying state of treatment efficacy and enable early detection of deterioration. Secondary goals were to identify clusters of rAHI trajectories which need distinct therapeutic strategies. RESULTS From telemonitoring records of 2860 CPAP-treated patients (age: 66.31 ± 12.92 years, 69.9% male), HMM estimated three states differing in variability within a given state and probability of shifting from one state to another. The daily inferred state informs on the need for a personalized action, while the sequence of states is a predictive indicator of treatment failure. Six clusters of rAHI trajectories were identified ranging from well-controlled patients (cluster 0: 669 (23%); mean rAHI 0.58 ± 0.59 events/h) to the most unstable (cluster 5: 470 (16%); mean rAHI 9.62 ± 5.62 events/h). CPAP adherence was 30 min higher in cluster 0 compared to clusters 4 and 5 (P value < 0.01). CONCLUSION This new approach based on HMM might constitute the backbone for deployment of patient-centred CPAP management improving the personalized interpretation of telemonitoring data, identifying individuals for targeted therapy and preventing treatment failure or abandonment. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s13167-021-00264-z.
Collapse
Affiliation(s)
- Alphanie Midelet
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- Probayes, Montbonnot-Saint-Martin, France
| | - Sébastien Bailly
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| | - Renaud Tamisier
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| | - Jean-Christian Borel
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- AGIR à dom. HomeCare Charity, 38240 Meylan, France
| | - Sébastien Baillieul
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| | | | | | - Jean-Louis Pépin
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| |
Collapse
|
24
|
Laaka A, Hollmén M, Bachour A. Evaluation of CPAP mask performance during 3 years of mask usage: time for reconsideration of renewal policies? BMJ Open Respir Res 2021; 8:8/1/e001104. [PMID: 34799354 PMCID: PMC8606764 DOI: 10.1136/bmjresp-2021-001104] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Accepted: 11/02/2021] [Indexed: 11/22/2022] Open
Abstract
Background Continuous positive airway pressure (CPAP) mask renewal policies vary inside and between countries. There are no independent studies on the optimal mask renewal frequency. We aimed to evaluate CPAP mask function over time in a real-life clinical setting, and to compare the results against current renewal policies. Methods Daily performance data of 1846 CPAP masks (65% nasal, 22% nasal pillows, 12% oronasal) were recorded from 450 participants (68% male, mean age 59 years) with obstructive sleep apnoea. The unintentional leak, Apnoea-Hypopnoea Index (CPAP-AHI) and usage data were exported from the CPAP device. Results Of 656 324 nights of CPAP usage, the mean renewal time was 497 days (SD 327), mean leak 5.7 L/min (SD 8.1) and CPAP-AHI 3.8 events/h (SD 3.6). The difference in mean leak between one (5.2 L/min, SD 7.5), 12 (6.0 L/min, SD 10.2) and 24 months (5.8 L/min, SD 7.5) was minimal (p=0.59). Mean CPAP-AHI remained normal and unchanged in nasal masks and pillows up to 30 months, and was highest in oronasal masks. Different mask manufacturers performed similarly. Masks’ daily or total usage did not affect the results. Shifting the mask renewal policy to 24 months could reduce the mask-related cost up to 50%–88%. Conclusions Nasal masks and pillows could be used at least 2 years without significant changes in unintentional leak and CPAP-AHI. We suggest updating the mask renewal policies of nasal masks and pillows; results on oronasal masks and other manufacturers CPAP devices need further verification.
Collapse
Affiliation(s)
- Atte Laaka
- Sleep Unit, Helsinki University Hospital Heart and Lung Center, Helsinki, Finland
| | - Maria Hollmén
- Faculty of Medicine, University of Helsinki, Helsinki, Finland.,Sleep Unit, Helsinki University Hospital Heart and Lung Center, Helsinki, Finland
| | - Adel Bachour
- Sleep Unit, Helsinki University Hospital Heart and Lung Center, Helsinki, Finland
| |
Collapse
|
25
|
Lepine J, Berthier F, Lorillou M, Maincent C, Perrin C. [Impact of AMARA VIEW™ interface on upper airway during nocturnal non invasive ventilation]. Rev Mal Respir 2021; 38:980-985. [PMID: 34763958 DOI: 10.1016/j.rmr.2021.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 08/16/2021] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Nasal masks can result in mouth leaks with implications on sleep quality. To reduce these leaks, oronasal masks are proposed. It has been shown that an oronasal mask can induce obstructive events in the upper airways (UA). Because of its fit around the nose, the Amara View™ facial mask may have less consequence on UA obstruction. METHODS This retrospective study assessed the impact of the Amara View™ mask on UA. The study was conducted on patients with chronic respiratory failure treated by home NIV with standard facial mask. Replacement of the standard facial mask by an Amara View™ mask was performed when the residual apnea hypopnea index recorded from the ventilator software exceeded 5/h. All patients underwent nocturnal respiratory polygraphy when on NIV with a standard facial mask and with an Amara View™ mask. Respiratory polygraphic traces were interpreted following the analysis methods published by the SomnoNIV Group. RESULTS Seven patients were studied. Although nocturnal oxygen saturation was similar between both masks, the index of UA obstruction without ventilatory blunting was significantly lower during NIV with the Amara View™ mask compared to the standard facial mask (P=0.01). CONCLUSIONS Nocturnal NIV using an Amara View™ facial interface may avoid UA obstruction without ventilatory command blunting.
Collapse
Affiliation(s)
- J Lepine
- Service de pneumologie, centre hospitalier Princesse-Grace, 1, avenue Pasteur, 98000 Monaco, Monaco
| | - F Berthier
- Département d'information médicale, Principauté de Monaco, centre hospitalier Princesse Grace, 1, avenue Pasteur, 98000 Monaco, Monaco
| | - M Lorillou
- Service de pneumologie, centre hospitalier Princesse-Grace, 1, avenue Pasteur, 98000 Monaco, Monaco
| | - C Maincent
- Service de pneumologie, centre hospitalier Princesse-Grace, 1, avenue Pasteur, 98000 Monaco, Monaco
| | - C Perrin
- Service de pneumologie, centre hospitalier Princesse-Grace, 1, avenue Pasteur, 98000 Monaco, Monaco.
| |
Collapse
|
26
|
The Importance of Mask Selection on Continuous Positive Airway Pressure Outcomes for Obstructive Sleep Apnea. An Official American Thoracic Society Workshop Report. Ann Am Thorac Soc 2021; 17:1177-1185. [PMID: 33000960 PMCID: PMC7640631 DOI: 10.1513/annalsats.202007-864st] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Continuous positive airway pressure (CPAP) remains the major treatment option for obstructive sleep apnea (OSA). The American Thoracic Society organized a workshop to discuss the importance of mask selection for OSA treatment with CPAP. In this workshop report, we summarize available evidence about the breathing route during nasal and oronasal CPAP and the importance of nasal symptoms for CPAP outcomes. We explore the mechanisms of air leaks during CPAP treatment and possible alternatives for leak control. The impact of nasal and oronasal CPAP on adherence, residual apnea-hypopnea index, unintentional leaks, and pressure requirements are also compared. Finally, recommendations for patient and partner involvement in mask selection are presented, and future directions to promote personalized mask selection are discussed.
Collapse
|
27
|
Ercelik M, Balbay EG, Gulhan PY, Cangur S, Arbak PM, Aytekin F, Elverisli MF. Factors affecting compliance with positive airway pressure therapy in obstructive sleep apnea. Sleep Breath 2021; 26:725-732. [PMID: 34328605 DOI: 10.1007/s11325-021-02447-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 07/12/2021] [Accepted: 07/14/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To investigate the factors affecting compliance with positive airway pressure (PAP) therapy and establish the relationship between compliance and pulmonary function tests (PFT) in patients with OSA. MATERIAL AND METHODS In this prospective study, patients with OSA using PAP devices were questioned about the complaints related to the device. Depression and anxiety scales along with PFT parameters were also assessed. RESULTS Of 98 participants, 63% were men. The mean age was 52.0 ± 9.6 years. Sixty-seven percent of the patients were compliant with their devices. A significant difference was observed between the proportion of the participants compliant or non-compliant with the device, based on OSA severity (p < 0.05). Beck depression inventory (BDI) and Beck anxiety inventory (BAI) scores of the compliant patients were significantly lower than those of the non-compliant patients (p < 0.001, p = 0.044, respectively). No statistically significant difference was detected between the groups regarding individual pulmonary function tests (p > 0.05). The rates of nasal mask use, not having difficulty in tolerating CPAP, falling asleep, absence of abdominal distension, no facial sores, no air leakage, patients benefiting from the device, reduction in daytime sleepiness, and the belief that they are receiving appropriate therapy in participants compliant with the device were higher than those in non-compliant participants (p < 0.05). The rates of claustrophobia and discomfort due to pressure were significantly lower in patients compliant with the device than in the non-compliant patients (p < 0.05). CONCLUSION While no relationship was detected between PFT parameters and PAP therapy compliance, significant factors affecting the device compliance were detected.
Collapse
Affiliation(s)
- Merve Ercelik
- Department of Chest Diseases, Afyonkarahisar Dinar State Hospital, 03400, Dinar, Afyonkarahisar, Turkey.
| | - Ege Gulec Balbay
- Department of Chest Diseases, Faculty of Medicine, Duzce University, Duzce, Turkey
| | - Pınar Yıldız Gulhan
- Department of Chest Diseases, Faculty of Medicine, Duzce University, Duzce, Turkey
| | - Sengul Cangur
- Department of Biostatistics and Medical Informatics, Faculty of Medicine, Duzce University, Düzce, Turkey
| | - Peri Meram Arbak
- Department of Chest Diseases, Faculty of Medicine, Duzce University, Duzce, Turkey
| | - Fuat Aytekin
- Department of Chest Diseases, Silopi State Hospital, Şırnak, Turkey
| | | |
Collapse
|
28
|
Pelletier-Fleury N, Le Vaillant M, Goupil F, Paris A, Pigeane T, Gagnadoux F, Meslier N. Risk-seeking attitude in health and safety domain is associated with continuous positive airway pressure discontinuation in patients with obstructive sleep apnea-a multicenter prospective cohort study. Sleep 2021; 44:5896478. [PMID: 32832982 DOI: 10.1093/sleep/zsaa156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 07/03/2020] [Indexed: 11/12/2022] Open
Abstract
STUDY OBJECTIVES Many studies have already looked at factors that may influence adherence to continuous positive airway pressure (CPAP) (severity of obstructive sleep apnea (OSA), patients' age, technical aspects, socioeconomic factors, living conditions, psychological factors). Although it has been shown that individuals' preference for risky behaviors in daily life can influence the use of care or adherence to drug therapies in care settings, this has never been tested in OSA. This study aims to analyze the association between risk attitude in the health/safety domain and CPAP discontinuation in a cohort of OSA patients. METHODS In a prospective multicenter cohort study nested within the IRSR sleep cohort, consecutive patients who were prescribed CPAP were monitored for at least 6 months. In addition to the data usually collected in the IRSR sleep cohort at baseline, patients also completed a risk-taking questionnaire using the Domain-Specific Risk-Taking (DOSPERT) scale. Cox's proportional hazards regression was used to model the risk of CPAP discontinuation as a function of a linear combination of variables hypothetically related to this risk including health risk attitude. RESULTS Of the 489 patients under CPAP, 12.1% (n = 59) were risk-seeking, 87.9% (n = 430) were risk-neutral, and none were risk-averse. Cox's model indicated that a risk-seeking attitude (p = 0.04) and an AHI <30 (p < 0.01) were significantly associated with CPAP discontinuation. CONCLUSIONS Patients with risk-seeking behaviors in daily life have been shown to be more likely to discontinue CPAP. The DOSPERT scale can be a useful tool for screening this specific group of patients in clinical practice.
Collapse
Affiliation(s)
- Nathalie Pelletier-Fleury
- Institut National de la Santé Et de la Recherche Médicale (INSERM UMR 1018), Université Paris-Saclay, Centre de Recherche en Epidémiologie et Santé des Populations, Hôpital Paul Brousse, 16 av Paul Vaillant Couturier, Villejuif, France
| | - Marc Le Vaillant
- Institut de Recherche en Santé Respiratoire des Pays de la Loire, Beaucouzé, France
| | - François Goupil
- Département de pneumologie, Centre Hospitalier, Le Mans, France
| | - Audrey Paris
- Département de pneumologie, Centre Hospitalier, Le Mans, France
| | | | - Frédéric Gagnadoux
- Département de pneumologie, Centre hospitalier universitaire, Angers, France
| | - Nicole Meslier
- Département de pneumologie, Centre hospitalier universitaire, Angers, France
| | | |
Collapse
|
29
|
Lebret M, Léotard A, Pépin JL, Windisch W, Ekkernkamp E, Pallero M, Sánchez-Quiroga MÁ, Hart N, Kelly JL, Patout M, Funk GC, Duiverman ML, Masa JF, Simonds A, Murphy PB, Wijkstra PJ, Dreher M, Storre J, Khouri C, Borel JC. Nasal versus oronasal masks for home non-invasive ventilation in patients with chronic hypercapnia: a systematic review and individual participant data meta-analysis. Thorax 2021; 76:1108-1116. [PMID: 33859049 DOI: 10.1136/thoraxjnl-2020-215613] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 01/31/2021] [Accepted: 03/12/2021] [Indexed: 11/04/2022]
Abstract
BACKGROUND The optimal interface for the delivery of home non-invasive ventilation (NIV) to treat chronic respiratory failure has not yet been determined. The aim of this individual participant data (IPD) meta-analysis was to compare the effect of nasal and oronasal masks on treatment efficacy and adherence in patients with COPD and obesity hypoventilation syndrome (OHS). METHODS We searched Medline and Cochrane Central Register of Controlled Trials for prospective randomised controlled trials (RCTs) of at least 1 month's duration, published between January 1994 and April 2019, that assessed NIV efficacy in patients with OHS and COPD. The main outcomes were diurnal PaCO2, PaO2 and NIV adherence (PROSPERO CRD42019132398). FINDINGS Of 1576 articles identified, 34 RCTs met the inclusion criteria and IPD were obtained for 18. Ten RCTs were excluded because only one type of mask was used, or mask data were missing. Data from 8 RCTs, including 290 IPD, underwent meta-analysis. Oronasal masks were used in 86% of cases. There were no differences between oronasal and nasal masks for PaCO2 (0.61 mm Hg (95% CI -2.15 to 3.38); p=0.68), PaO2 (-0.00 mm Hg (95% CI -4.59 to 4.58); p=1) or NIV adherence (0·29 hour/day (95% CI -0.74 to 1.32); p=0.58). There was no interaction between the underlying pathology and the effect of mask type on any outcome. INTERPRETATION Oronasal masks are the most used interface for the delivery of home NIV in patients with OHS and COPD; however, there is no difference in the efficacy or tolerance of oronasal or nasal masks.
Collapse
Affiliation(s)
- Marius Lebret
- Pneumology Department, Institut universitaire de cardiologie et de pneumologie de Québec, Quebec, Quebec, Canada
| | | | - Jean Louis Pépin
- HP2 Laboratory INSERM U1042, Univ. Grenoble Alpes, Grenoble, France
| | - Wolfram Windisch
- Department of Pneumology and Critical Care Medicine, Cologne Merheim Hospital, Cologne, Germany.,Depatment of Pneumology, Kliniken der Stadt Köln gGmbH, Cologne, Germany.,Faculty of Health, Witten/Herdecke University, Witten, Germany
| | - Emelie Ekkernkamp
- Department of Pneumology, University Hospital Freiburg, Freiburg, Germany
| | - Mercedes Pallero
- Respiratory Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain.,CIBER de Enfermedades Respiratorias (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
| | | | - Nicholas Hart
- Lane Fox Respiratory Service, Guy's & St Thomas' NHS Foundation Trust, London, UK
| | - Julia L Kelly
- NIHR Respiratory Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust and Imperial College, London, UK
| | - Maxime Patout
- Departement of pneumology and intensive care, University Hospital, Rouen, France
| | - Georg Chistian Funk
- Karl-Landsteiner-Institute for Lung Research and Pulmonary Oncology, Vienna, Austria
| | - Marieke L Duiverman
- Pulmonary Diseases and Home Mechanical Ventilation, University Medical Centre Groningen, Groningen, Netherlands
| | - Juan F Masa
- San Pedro de Alcantara Hospital, Caceres, Spain
| | - Anita Simonds
- National Institute of Health Research Respiratory Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK.,Respiratory Medicine, Imperial College London, London, UK
| | | | - Peter J Wijkstra
- Pulmonary Diseases, University of Groningen, University Medical Centre Groningen, Groningen, Netherlands
| | - Michael Dreher
- Pneumology and Intensive Care Medicine, Universitatsklinikum Aachen, Aachen, Nordrhein-Westfalen, Germany
| | - Jan Storre
- Pneumology Department, University Medical Center Freiburg, Freiburg, Germany.,Praxis Pneumologie Solln, Munich, Germany
| | - Charles Khouri
- HP2 Laboratory INSERM 1042, Grenoble Universites, Saint-Martin-d'Heres, France
| | | |
Collapse
|
30
|
Carlier S, Bruyneel AV, Bruyneel M. Pressure adjustment is the most useful intervention for improving compliance in telemonitored patients treated with CPAP in the first 6 months of treatment. Sleep Breath 2021; 26:125-132. [PMID: 33846930 DOI: 10.1007/s11325-021-02367-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/14/2021] [Accepted: 04/01/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE Telemonitoring (TMg) for patients treated with continuous positive airway pressure (CPAP) is now routine care in some sleep labs. The purpose of the present study was to identify technical interventions associated with improved CPAP compliance in a real-life cohort of newly telemonitored patients with obstructive sleep apnea (OSA) during the first 6 months of treatment. METHODS All patients with moderate-to-severe OSA (apnea-hypopnea index (AHI) ≥ 15/h) who were newly treated with CPAP were included in the study and telemonitored. A group educational session was scheduled after 1 month. Technical interventions were performed at the patient's request and during scheduled visits and the impact of each intervention on CPAP therapy compliance was collected. RESULTS Between May 2018 and Dec 2019, 349 patients newly diagnosed with OSA were hospitalized in the sleep lab for CPAP titration and 212 patients were included (mean age 54.6 ± 13.1 years, mean BMI 31.7 ± 5.8 kg/m2, mean AHI 42.8 ± 22.0). TMg acceptance rate was 87%. Mean 6-month compliance was 275 ± 154 min, 13% stopped CPAP, and 17% were non-compliant. Correlations were observed between BMI (r = 0.15, p = 0.029), median and 95th percentile leaks (r = -0.23 and -0.18, p = 0.016 and 0.002), and CPAP compliance. During follow-up, 92 interventions were required, mainly for mask change (n = 80). Pressure modification (n = 16) was the only intervention that increased CPAP use > 30 min/night, p = 0.021. CONCLUSION Pressure modification was the only adaptation that significantly increased CPAP compliance during the first 6 months. Remote TMg allows providing daily, accurate, and immediate feedback that could help clinicians to confirm that the CPAP treatment is effective.
Collapse
Affiliation(s)
- Sarah Carlier
- Department of Pulmonary Medicine, CHU Saint-Pierre, Brussels, Belgium.,Université Libre de Bruxelles (ULB), Brussels, Belgium
| | | | - Marie Bruyneel
- Department of Pulmonary Medicine, CHU Saint-Pierre, Brussels, Belgium. .,Université Libre de Bruxelles (ULB), Brussels, Belgium.
| |
Collapse
|
31
|
Yui MS, Tominaga Q, Lopes BCP, Eckeli AL, de Almeida LA, Rabelo FAW, Küpper DS, Valera FCP. Can drug-induced sleep endoscopy (DISE) predict compliance with positive airway pressure therapy? A pilot study. Sleep Breath 2021; 26:109-116. [PMID: 33829370 DOI: 10.1007/s11325-021-02360-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 01/07/2021] [Accepted: 03/24/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Drug-induced sleep endoscopy (DISE) has been poorly explored as an examination to assess positive airway pressure (PAP) therapy in patients with obstructive sleep apnea (OSA). The present study aimed to identify by DISE possible characteristics related to low compliance with PAP therapy due to respiratory complaints. METHODS Patients using PAP for OSA underwent DISE in two conditions: (1) baseline (without PAP) and (2) PAP (with the same mask and airway pressure used at home). We compared patients reporting low compliance to PAP due to respiratory complaints to those well-adapted to therapy. VOTE classification (assessment of velopharynx, oropharynx, tongue base, and epiglottis) and TOTAL VOTE score (the sum of VOTE scores at each anatomical site) were assessed. ROC curve analyzed the accuracy of TOTAL VOTE to predict low compliance due to persistent pharyngeal obstruction in both conditions. RESULTS Of 19 patients enrolled, all presented multilevel pharyngeal obstruction at baseline condition, with no difference between groups at this study point. When PAP was added, the median VOTE value was higher in the epiglottis (P value=0.02) and tended to be higher at the velum and tongue base in the poorly adapted group; TOTAL VOTE score was also significantly increased in patients with low compliance (P value<0.001). ROC curve demonstrated that patients with TOTAL VOTE scored 2.5 or more during DISE with PAP presented a 4.6-fold higher risk for low compliance with PAP therapy due to pharyngeal obstruction (AUC: 0.88±0.07; P value<0.01; sensitivity: 77%; specificity: 83%). CONCLUSIONS Adding PAP during a DISE examination may help to predict persistent pharyngeal obstruction during PAP therapy.
Collapse
Affiliation(s)
- Mariane S Yui
- ENT Division, Clinics Hospital, Ribeirao Preto Medical School, University of Sao Paulo, Av. Bandeirantes, 3900-12o andar, CEP 14049-900, Ribeirão Preto, São Paulo, Brazil
| | - Quedayr Tominaga
- ENT Division, Clinics Hospital, Ribeirao Preto Medical School, University of Sao Paulo, Av. Bandeirantes, 3900-12o andar, CEP 14049-900, Ribeirão Preto, São Paulo, Brazil
| | - Bruno C P Lopes
- Anesthesiology Division, Clinics Hospital, Ribeirao Preto Medical School, University of Sao Paulo, Ribeirao Preto, Brazil
| | - Alan L Eckeli
- Neurosciences Division, Clinics Hospital, Ribeirao Preto Medical School, University of Sao Paulo, Ribeirao Preto, Brazil
| | - Leila A de Almeida
- Neurosciences Division, Clinics Hospital, Ribeirao Preto Medical School, University of Sao Paulo, Ribeirao Preto, Brazil
| | | | - Daniel S Küpper
- ENT Division, Clinics Hospital, Ribeirao Preto Medical School, University of Sao Paulo, Av. Bandeirantes, 3900-12o andar, CEP 14049-900, Ribeirão Preto, São Paulo, Brazil
| | - Fabiana C P Valera
- ENT Division, Clinics Hospital, Ribeirao Preto Medical School, University of Sao Paulo, Av. Bandeirantes, 3900-12o andar, CEP 14049-900, Ribeirão Preto, São Paulo, Brazil.
| |
Collapse
|
32
|
Pahkala R, Suominen AL. Adherence to oral appliance treatment and its determinants in obstructive sleep apnoea patients. Eur J Orthod 2021; 43:408-414. [PMID: 33555322 DOI: 10.1093/ejo/cjaa084] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND AND OBJECTIVES Treatment effectiveness, in terms of health benefits, is a composite of efficacy and adherence. Oral appliance (OA) usage is mainly based on self-reports, but nowadays, objective adherence monitoring for OAs is available. This study investigated the objective OA adherence and its determinants in obstructive sleep apnoea (OSA) patients. MATERIALS AND METHODS There were 29 subjects who were treated with OA; mean [SD] age 51.4 [11.1]; mean apnoea-hypopnoea index (AHI) [SD] 19.5 [10.0]. Anthropometric and sociodemographic parameters, AHI, daytime sleepiness, snoring, and adverse effects of OA as potential determinants were evaluated. Patients were classified as regular users if they wore OA at least 4 hours nightly 5-7 nights a week. Statistical analyses included the chi-square test, t-test, Mann-Whitney U-test, and linear regression analyses. RESULTS At the 3-month follow-up, 68% of subjects were regular users and at 12-month follow-up, 64%. AHI, sociodemographic parameters, or adverse effects were not associated with OA adherence. Snoring seemed to improve weakly adherence, whereas mandibular retrusion reduced the weekly use, and smoking the nightly use of OAs. LIMITATIONS The follow-up time was short, and there were a relatively small number of patients with obtainable adherence data, therefore it is difficult to establish if OA therapy alone is a successful long-term treatment option for OSA patients. CONCLUSIONS/IMPLICATIONS Adherence to OA therapy is mainly the outcome of patients' subjective comfort in everyday life through eliminating social disturbance of snoring. To best meet a subject's individual treatment need and to prevent suboptimal use of OA, a patient-tailored therapy including digital wear-time documentation is recommended.
Collapse
Affiliation(s)
- Riitta Pahkala
- Department of Oral and Maxillofacial Diseases, Kuopio University Hospital, Kuopio, Finland
| | - Anna Liisa Suominen
- Department of Oral Public Health, Institute of Dentistry, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
33
|
Fujino Y, Oka Y, Wakamura T. Seasonal effects on the continuous positive airway pressure adherence of patients with obstructive sleep apnea. Sleep Med 2021; 80:126-133. [PMID: 33596526 DOI: 10.1016/j.sleep.2021.01.024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 01/12/2021] [Accepted: 01/15/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This study examined seasonal differences in continuous positive airway pressure (CPAP) therapy adherence among patients with obstructive sleep apnea (OSA). METHODS Patients aged ≥20 years with OSA who had used CPAP devices on the automatic setting for >12 consecutive months (n = 141) were included in this retrospective study from December 2015-2016. The information of CPAP use (pressure, hours of actual use) was extracted from database downloaded from patients' CPAP devices. Patients were divided into adherent and non-adherent groups using the cutoff point of 70% CPAP use for ≥4 h daily over the 1-year study period. CPAP use data were averaged for each season. RESULTS Patients in the adherent group were significantly older than those in the non-adherent group (p < 0.001). In the adherent group, the rate of ≥4 h daily CPAP use was significantly lower, the daily duration of CPAP use was significantly shorter, and the residual apnea-hypopnea index (AHI; events/hour) was significantly higher in summer than in other seasons (all p < 0.001). In the non-adherent group, the duration of daily CPAP use and the AHI differed significantly between winter and summer (p = 0.008 and p < 0.001, respectively). CONCLUSIONS Seasonal changes were associated with the CPAP adherence of patients with OSA. The study findings suggest that there is possibility of increasing the duration of CPAP use by adjusting the bedroom environment in hot and humid seasons.
Collapse
Affiliation(s)
- Yoko Fujino
- Environmental Health Nursing, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan; Center for Sleep Medicine, Ehime University Hospital, 454, Toon-city, Ehime, 791-0204, Japan.
| | - Yasunori Oka
- Center for Sleep Medicine, Ehime University Hospital, 454, Toon-city, Ehime, 791-0204, Japan
| | - Tomoko Wakamura
- Environmental Health Nursing, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
34
|
Rotty MC, Suehs CM, Mallet JP, Martinez C, Borel JC, Rabec C, Bertelli F, Bourdin A, Molinari N, Jaffuel D. Mask side-effects in long-term CPAP-patients impact adherence and sleepiness: the InterfaceVent real-life study. Respir Res 2021; 22:17. [PMID: 33451313 PMCID: PMC7809735 DOI: 10.1186/s12931-021-01618-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 01/06/2021] [Indexed: 02/06/2023] Open
Abstract
Background For some patients, Continuous Positive Airway Pressure (CPAP) remains an uncomfortable therapy despite the constant development of technological innovations. To date, no real life study has investigated the relationship between mask related side-effects (MRSEs) and CPAP-non-adherence (defined as < 4 h/day) or residual-excessive-sleepiness (RES, Epworth-Sleepiness-Scale (ESS) score ≥ 11) in the long-term. Methods The InterfaceVent-CPAP study is a prospective real-life cross-sectional study conducted in an apneic adult cohort undergoing at least 3 months of CPAP with unrestricted mask-access (34 different masks). MRSEs were evaluated using visual-analogue-scales, CPAP-data using CPAP-software, sleepiness using ESS. Results 1484 patients were included in the analysis (72.2% male, median age 67 years (IQ25–75: 60–74), initial Apnea–Hypopnea-Index (AHI) of 39 (31–56)/h, residual AHIflow was 1.9 (0.9–4) events/h), CPAP-treatment lasted 4.4 (2.0–9.7) years, CPAP-usage was 6.8 (5.5–7.8) h/day, the prevalence of CPAP-non-adherence was 8.6%, and the prevalence of RES was 16.17%. Leak-related side-effects were the most prevalent side-effects (patient-reported leaks concerned 75.4% of responders and had no correlation with CPAP-reported-leaks). Multivariable logistic regression analyses evaluating explanatory-variable (demographic data, device/mask data and MRSEs) effects on variables-of-interest (CPAP-non-adherence and RES), indicated for patient-MRSEs significant associations between: (i) CPAP-non-adherence and dry-mouth (p = 0.004); (ii) RES and patient-reported leaks (p = 0.007), noisy mask (p < 0.001), dry nose (p < 0.001) and harness pain (p = 0.043). Conclusion In long-term CPAP-treated patients, leak-related side-effects remain the most prevalent side-effects, but patient-reported leaks cannot be predicted by CPAP-reported-leaks. Patient-MRSEs can be independently associated with CPAP-non-adherence and RES, thus implying a complementary role for MRSE questionnaires alongside CPAP-device-reported-data for patient monitoring. Trial registration InterfaceVent is registered with ClinicalTrials.gov (NCT03013283).
Collapse
Affiliation(s)
- Marie-Caroline Rotty
- IMAG, CNRS, Montpellier University, Montpellier University Hospital, Montpellier, France.,Apard Groupe Adène, Montpellier, France
| | - Carey M Suehs
- Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, CHRU Montpellier, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France.,Department of Medical Information, Montpellier University Hospital, Montpellier, France
| | - Jean-Pierre Mallet
- Apard Groupe Adène, Montpellier, France.,Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, CHRU Montpellier, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France
| | | | - Jean-Christian Borel
- Inserm U1042, HP2 (Hypoxia PhysioPathology) LaboratoryCentre Hospitalier Universitaire Grenoble Alpes, Grenoble Alps University, Grenoble, France
| | - Claudio Rabec
- Pulmonary Department and Respiratory Critical Care Unit, University Hospital Dijon, Dijon, France
| | - Fanny Bertelli
- IMAG, CNRS, Montpellier University, Montpellier University Hospital, Montpellier, France.,Apard Groupe Adène, Montpellier, France
| | - Arnaud Bourdin
- Apard Groupe Adène, Montpellier, France.,Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, CHRU Montpellier, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France.,PhyMedExp (INSERM U 1046, CNRS UMR9214), Montpellier University, Montpellier, France
| | - Nicolas Molinari
- IMAG, CNRS, Montpellier University, Montpellier University Hospital, Montpellier, France.,Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, CHRU Montpellier, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France
| | - Dany Jaffuel
- Apard Groupe Adène, Montpellier, France. .,Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, CHRU Montpellier, 371, Avenue Doyen Giraud, 34295, Montpellier Cedex 5, France. .,PhyMedExp (INSERM U 1046, CNRS UMR9214), Montpellier University, Montpellier, France. .,Pulmonary Disorders and Respiratory Sleep Disorders Unit, Polyclinic Saint-Privat, Boujan sur Libron, France.
| |
Collapse
|
35
|
Premaraj TS, Stadiem J, Premaraj SA, Davies CR, Dennis M, Harrington JJ. Continuous Positive Airway Pressure-Mandibular Advancement Device Combination Therapy for Moderate-to-Severe Obstructive Sleep Apnea: A Preliminary Study. Eur J Dent 2021; 16:749-755. [PMID: 33412609 PMCID: PMC9683874 DOI: 10.1055/s-0040-1719220] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objectives
The purpose of this pilot study was to determine whether compliance to auto-adjusting positive airway pressure (APAP) improves with the addition of a mandibular advancement device (MAD). Secondary outcome measures included were APAP pressure, subjective daytime sleepiness, apnea–hypopnea index (AHI), and mask leaks.
Setting and Sample Population
Participants included were diagnosed with moderate-to-severe obstructive sleep apnea (OSA) and became noncompliant to prescribed APAP. Thirteen participants with a mean age of 61.6 years were recruited for this study.
Materials and Methods
All participants were given a MAD to use with their APAP. Parameters measured included APAP pressure, AHI, mask leak reported via ResMed AirViewTM software, and self-reported daytime sleepiness (Epworth Sleepiness Scale [ESS]). A paired two-sample for mean
t
-test was performed to determine significance.
Results
The mean difference of pre- and postintervention APAP compliance was 23.1%, which was statistically significant (
p
= 0.015). The mean APAP air pressures were unchanged. The difference between pre- and postintervention mean ESS scores was 1.4 and was statistically significant (
p
= 0.027). The mean difference between pre- and postintervention AHI values and mask leak showed no significant difference.
Conclusion
This study showed that combination of APAP-MAD therapy, for patients with moderate-to-severe OSA who were noncompliant to APAP use, significantly increased compliance with APAP therapy, and significantly decreased the daytime sleepiness of participants.
Collapse
Affiliation(s)
- Thyagaseely Sheela Premaraj
- Department of Orthodontics, College of Dentistry, University of Nebraska Medical Center, Lincoln, Nebraska, United States
| | - Jacob Stadiem
- Department of Orthodontics, University of Nebraska Medical Center, Lincoln, Nebraska, United States
| | - Shyamaly Arya Premaraj
- College of Dentistry, University of Nebraska Medical Center, Lincoln, Nebraska, United States
| | - Charles R Davies
- Carle Neuroscience Institute, Carle Physician Group, University of Illinois at Urbana, Illinois, United States
| | - Matthew Dennis
- Division of Pediatric Pulmonology & Sleep Medicine, University of Nebraska Medical Center, Children's Hospital & Medical Center, Omaha, Nebraska, United States
| | - John J Harrington
- Division of Pulmonary, Critical Care and Sleep Medicine, University of Nebraska Medical Center, Omaha, Nebraska, United States
| |
Collapse
|
36
|
Efficacy of nasal masks versus nasal pillows masks during continuous positive airway pressure titration for patients with obstructive sleep apnea. Sleep Breath 2021; 25:1-8. [PMID: 33403598 DOI: 10.1007/s11325-020-02251-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 11/02/2020] [Accepted: 11/12/2020] [Indexed: 10/22/2022]
Abstract
PURPOSE Nasal masks are usually the first choice for CPAP therapy, but patients may experience side effects. There are limited data regarding the efficacy of nasal pillows masks during CPAP titration. This study aimed to compare the polysomnography outcomes during CPAP titration while comparing two types of masks (nasal and pillows) and to assess whether or not the patient characteristics differed between mask preferences. METHODS In a sleep-disorders clinic, we prospectively analyzed all patients undergoing CPAP titration for three consecutive months. CPAP pressures were manually titrated. Anthropometric data (age, sex, body mass index, and neck and waist circumferences) and OSA severity were documented. Patients completed a self-administered questionnaire that measured nasal obstruction (NOSE scale). Before titration, both types of masks were presented to patients, and each of them chose the one they preferred. RESULTS Of 157 patients, 55% (n = 86) used nasal masks, and 45% (n = 71) used nasal pillows masks. There was no difference according to mask type chosen by age, sex, body mass index, neck and waist circumferences, and NOSE scale. Polysomnography outcomes were similar between the mask groups. The mean CPAP level was 9.4 ± 1.8 cm H2O for nasal masks and 9.1 ± 2.0 cm H2O for nasal pillows (p = 0.61). Residual apnea-hypopnea index was 3.0 ± 2.8 events/h for nasal mask and 3.5 ± 4.1 events/h for pillow mask (p = 0.28). Baseline AHI, body mass index, neck and waist circumferences, and residual AHI were independent predictors of a higher CPAP pressure for both groups (p < 0.0001). CONCLUSIONS Nasal pillows masks seem to be as effective as nasal masks and may be considered to be an initial choice for CPAP titration.
Collapse
|
37
|
Treatment of Obstructive Sleep Apnea: Achieving Adherence to Positive Airway Pressure Treatment and Dealing with Complications. Sleep Med Clin 2020; 15:227-240. [PMID: 32386697 DOI: 10.1016/j.jsmc.2020.02.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Obstructive sleep apnea is a common and treatable condition, but therapeutic adherence is limited by numerous factors. Despite advances in positive airway pressure (PAP) technology and a multitude of effective pharmacologic and behavioral therapeutic interventions to overcome the most common barriers to PAP, adherence has not increased significantly over the past 30 years. This review aims to identify the most important factors that impact adherence, common barriers to treatment, and evidence-based treatment strategies to maximize the effectiveness of PAP treatment. Complications of PAP treatment and mitigation techniques are also discussed.
Collapse
|
38
|
Bros J, Poulet C, Methni JE, Deschaux C, Gandit M, Pauwels PJ, Charavel M. Determination of risks of lower adherence to CPAP treatment before their first use by patients. J Health Psychol 2020; 27:223-235. [PMID: 32783470 DOI: 10.1177/1359105320942862] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
A better understanding of Continuous Positive Airway Pressure (CPAP) adherence is a priority in improving patient care. To Identify adherence typology with a longitudinal approach, and explore the early determinants of lower adherence to CPAP. Obstructive sleep apnea patients (N = 204). Prospective and longitudinal study.A classification into four profiles was observed: "Regular Adherents," "Non-Regular Adherents," "Persistent Non-Adherents," and "Non-Persistent Non-Adherents." Specific biopsychosocial factors make it possible to evaluate the risk of belonging to a lower adherence profile. We propose a novel approach of CPAP treatment adherence. Several pre-determinants have been identified.
Collapse
Affiliation(s)
- Julie Bros
- Université Grenoble Alpes, LIP/PC2S, Grenoble, Saint-Martin-d'Hères, France
| | - Caroline Poulet
- Université Grenoble Alpes, LIP/PC2S, Grenoble, Saint-Martin-d'Hères, France
| | - Jonathan El Methni
- Université Paris Descartes, Sorbonne Paris Cité, Laboratoire MAP 5, UMR CNRS 8145., Paris, France
| | | | - Marc Gandit
- Université Grenoble Alpes, LIP/PC2S, Grenoble, Saint-Martin-d'Hères, France
| | | | - Marie Charavel
- Université Grenoble Alpes, LIP/PC2S, Grenoble, Saint-Martin-d'Hères, France
| |
Collapse
|
39
|
Duarte RLM, Mendes BA, Oliveira-E-Sá TS, Magalhães-da-Silveira FJ, Gozal D. Nasal versus oronasal mask in patients under auto-adjusting continuous positive airway pressure titration: a real-life study. Eur Arch Otorhinolaryngol 2020; 277:3507-3512. [PMID: 32725272 DOI: 10.1007/s00405-020-06242-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 07/22/2020] [Indexed: 01/04/2023]
Abstract
PURPOSE Mask type (nasal versus oronasal) can affect the optimal pressure required to correct the apnea/hypopnea index (AHI) in obstructive sleep apnea (OSA) subjects treated with CPAP. Our objective was to evaluate if mask type influenced CPAP titration outcomes in OSA patients. METHODS A retrospective study of individuals with a baseline AHI ≥ 15.0/h, who received an auto-adjusting CPAP titrating device (S9 AutoSet ResMed®) in a sleep-lab setting. The mask type oronasal (OM) or nasal (NM) was always selected by the patients. Optimal pressure requirements, leak, and residual AHI were compared based on mask type. RESULTS Overall, 436 patients were included: 283 with NM (64.9%) and 153 with OM (35.1%). At baseline, NM and OM cohorts had similar AHI (p = 0.160). Patients allocated to the OM cohort had a higher 95th percentile pressure, a higher 95th percentile leak, and a higher residual AHI than those with a NM: pressure requirement: 12.9 cm H2O (IQR: 10.6-15.0) versus 10.7 cm H2O (IQR: 9.2-12.3); leak: 21.6 L/min (IQR: 9.6-37.2) versus 9.6 L/min (IQR: 3.6-19.2); and residual AHI: 4.9/h (IQR: 2.4-10.2) versus 2.2/h (IQR: 1.0-4.4), respectively (p < 0.001 for all). CONCLUSIONS CPAP mask type based on individual preferences exerts profound effects on optimal CPAP pressures and efficacy. Patients titrated with OM showed higher pressure requirements, had higher a leak, and higher residual AHI when compared to NM, which may adversely impact treatment adherence and other health outcomes.
Collapse
Affiliation(s)
- Ricardo L M Duarte
- SleepLab, Laboratório de Estudo dos Distúrbios do Sono, Centro Médico BarraShopping, Avenida das Américas 4666, sala 309, Barra da Tijuca, Rio de Janeiro, 22649-900, Brazil. .,Instituto de Doenças do Tórax, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil.
| | - Bruno A Mendes
- Hospital de Santa Marta, Centro Hospitalar Universitário Lisboa Central, Lisbon, Portugal
| | - Tiago S Oliveira-E-Sá
- Hospital de Santa Marta, Centro Hospitalar Universitário Lisboa Central, Lisbon, Portugal.,NOVA Medical School, Faculdade de Ciências Médicas, Universidade Nova de Lisboa, Lisbon, Portugal
| | - Flavio J Magalhães-da-Silveira
- SleepLab, Laboratório de Estudo dos Distúrbios do Sono, Centro Médico BarraShopping, Avenida das Américas 4666, sala 309, Barra da Tijuca, Rio de Janeiro, 22649-900, Brazil
| | - David Gozal
- Department of Child Health, University of Missouri School of Medicine, Columbia, USA
| |
Collapse
|
40
|
Epstein M, Musa T, Chiu S, Costanzo J, Dunne C, Cerrone F, Capone R. Use of the WatchPAT to detect occult residual sleep-disordered breathing in patients on CPAP for obstructive sleep apnea. J Clin Sleep Med 2020; 16:1073-1080. [PMID: 32118574 DOI: 10.5664/jcsm.8406] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
STUDY OBJECTIVES To determine the accuracy of the apnea-hypopnea index (AHI) as measured by continuous positive airway pressure (CPAP) machines by simultaneously employing a home sleep apnea testing device (WatchPAT 200, Itamar Medical, Israel [WPAT]) in patients suspected of having residual sleep-disordered breathing (SDB). METHODS Patients with new, recurrent, or worsening signs, symptoms, or comorbidities associated with obstructive sleep apnea underwent home sleep apnea testing using WPAT while simultaneously using CPAP at their usual prescribed settings. CPAP AHI and WPAT AHI, respiratory disturbance index, and oximetry readings were then compared. RESULTS We identified an elevated AHI with WPAT testing in nearly half of patients with clinically suspected residual SDB and a normal CPAP AHI. WPAT detected additional respiratory events as well, including rapid eye movement-related apneas, respiratory effort-related arousals, and hypoxemia. CONCLUSIONS WPAT AHI was significantly higher than simultaneous CPAP AHI in nearly half of those patients with clinically suspected residual SDB being treated with CPAP. Additional respiratory disturbances, including rapid eye movement-related respiratory events, respiratory effort-related arousals, and hypoxemia, were elucidated only with the use of the WPAT. Residual SDB may have potential clinical consequences, including reduced CPAP adherence, ongoing hypersomnolence, and other health-related sequelae. Simultaneous WPAT testing of patients with a normal CPAP AHI may represent a valuable tool to detect clinically suspected residual SDB or to ensure adequate treatment in high-risk patients with obstructive sleep apnea in general.
Collapse
Affiliation(s)
- Matthew Epstein
- Atlantic Health Sleep Centers, Livingston, New Jersey.,Atlantic Health System, Morristown, New Jersey.,New Jersey Medical School, Newark, New Jersey
| | - Tariq Musa
- Atlantic Health System, Morristown, New Jersey
| | | | | | - Christine Dunne
- Atlantic Health Sleep Centers, Livingston, New Jersey.,Atlantic Health System, Morristown, New Jersey
| | - Federico Cerrone
- Atlantic Health Sleep Centers, Livingston, New Jersey.,Atlantic Health System, Morristown, New Jersey
| | - Robert Capone
- Atlantic Health Sleep Centers, Livingston, New Jersey.,Atlantic Health System, Morristown, New Jersey
| |
Collapse
|
41
|
Adler D, Bailly S, Benmerad M, Joyeux-Faure M, Jullian-Desayes I, Soccal PM, Janssens JP, Sapène M, Grillet Y, Stach B, Tamisier R, Pépin JL. Clinical presentation and comorbidities of obstructive sleep apnea-COPD overlap syndrome. PLoS One 2020; 15:e0235331. [PMID: 32645005 PMCID: PMC7347183 DOI: 10.1371/journal.pone.0235331] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Accepted: 06/14/2020] [Indexed: 12/21/2022] Open
Abstract
Background More advanced knowledge is needed on how COPD alters the clinical presentation of obstructive sleep apnea (OSA) and how the association of both diseases, known as ‘overlap syndrome’ (OVS), impacts on cardiovascular health. Objective To investigate differences between patients with OVS and those with moderate-to-severe OSA alone. Methods A cross-sectional study conducted in the French National Sleep Apnea Registry between January 1997 and January 2017. Univariable and multivariable logistic regression models were used to compare OVS versus OSA alone on symptoms and cardiovascular health. Results 46,786 patients had moderate-to-severe OSA. Valid spirometry was available for 16,466 patients: 14,368 (87%) had moderate-to-severe OSA alone and 2098 (13%) had OVS. A lower proportion of OVS patients complained of snoring, morning headaches and excessive daytime sleepiness compared to OSA alone (median Epworth Sleepiness Scale score: 9 [interquartile range (IQR) 6–13] versus 10 (IQR 6–13), respectively; P <0.02). Similarly, a lower proportion of OVS patients (35.6% versus 39.4%, respectively; P <0.01) experienced sleepiness while driving. In contrast, 63.5% of the OVS population experienced nocturia compared to 58.0% of the OSA population (P<0.01). Apnea hypopnea index (36 [25; 52] vs 33.1 [23.3; 50]), oxygen desaturation index (28 [15; 48] vs 25.2 [14; 45]) and mean nocturnal SaO2 (92 [90; 93.8] vs 93 [91.3; 94]) were significantly more altered in the OVS group. Associated COPD had no effect on the prevalence of hypertension and stroke. After controlling for main confounders, COPD severity was associated in a dose-response relationship with a higher prevalence of coronary heart disease, heart failure and peripheral arteriopathy. Conclusions In adults with moderate-to-severe OSA, OVS was minimally symptomatic, but exhibited higher odds for prevalent coronary heart disease, heart failure and peripheral arteriopathy.
Collapse
Affiliation(s)
- Dan Adler
- Division of Pneumology, Geneva University Hospitals, Geneva, Switzerland.,University of Geneva Faculty of Medicine, Geneva, Switzerland
| | - Sébastien Bailly
- HP2 Laboratory, INSERM U1042, University Grenoble Alpes, Grenoble, France.,EFCR Laboratory, Pole Thorax et Vaisseaux, Grenoble Alpes University Hospital, Grenoble, France
| | - Meriem Benmerad
- HP2 Laboratory, INSERM U1042, University Grenoble Alpes, Grenoble, France.,EFCR Laboratory, Pole Thorax et Vaisseaux, Grenoble Alpes University Hospital, Grenoble, France
| | - Marie Joyeux-Faure
- HP2 Laboratory, INSERM U1042, University Grenoble Alpes, Grenoble, France.,EFCR Laboratory, Pole Thorax et Vaisseaux, Grenoble Alpes University Hospital, Grenoble, France
| | - Ingrid Jullian-Desayes
- HP2 Laboratory, INSERM U1042, University Grenoble Alpes, Grenoble, France.,EFCR Laboratory, Pole Thorax et Vaisseaux, Grenoble Alpes University Hospital, Grenoble, France
| | - Paola Marina Soccal
- Division of Pneumology, Geneva University Hospitals, Geneva, Switzerland.,University of Geneva Faculty of Medicine, Geneva, Switzerland
| | - Jean Paul Janssens
- Division of Pneumology, Geneva University Hospitals, Geneva, Switzerland.,University of Geneva Faculty of Medicine, Geneva, Switzerland
| | - Marc Sapène
- Private Practice Sleep and Respiratory Disease Centre, Nouvelle Clinique Bel Air, Bordeaux, France
| | - Yves Grillet
- Private Practice Sleep and Respiratory Disease Centre, Valence, France
| | - Bruno Stach
- Private Practice Sleep and Respiratory Disease Centre, Valenciennes, France
| | - Renaud Tamisier
- HP2 Laboratory, INSERM U1042, University Grenoble Alpes, Grenoble, France.,EFCR Laboratory, Pole Thorax et Vaisseaux, Grenoble Alpes University Hospital, Grenoble, France
| | - Jean-Louis Pépin
- Division of Pneumology, Geneva University Hospitals, Geneva, Switzerland.,HP2 Laboratory, INSERM U1042, University Grenoble Alpes, Grenoble, France.,EFCR Laboratory, Pole Thorax et Vaisseaux, Grenoble Alpes University Hospital, Grenoble, France
| |
Collapse
|
42
|
Lebret M, Jaffuel D, Suehs CM, Mallet JP, Lambert L, Rotty MC, Pépin JL, Matzner-Lober E, Molinari N, Borel JC. Feasibility of Type 3 Polygraphy for Evaluating Leak Determinants in CPAP-Treated OSA Patients: A Step Toward Personalized Leak Management. Chest 2020; 158:2165-2171. [PMID: 32544491 DOI: 10.1016/j.chest.2020.05.593] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 04/01/2020] [Accepted: 05/17/2020] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Unintentional leaks (ULs) are frequent adverse effects in CPAP-treated patients. We previously published a novel methodology for analyzing the determinants of UL using polysomnography. We now propose a simplified recording system using a type 3 polygraphic device (Somnolter; Nomics S.A.). RESEARCH QUESTION (1) To describe individual UL determinants provided by the Somnolter software in automatic-CPAP-treated OSA patients; (2) To subsequently describe the clinical consensus of four physicians on how to manage each individual UL situation. STUDY DESIGN AND METHODS Somnoler recordings performed under nasal automatic-CPAP were automatically analyzed with APIOS software. For each polygraphic recording, APIOS provided the OR and the CIs for potential determinants of UL: mouth opening, CPAP pressure, body position, and mandibular oscillation. Based on these results, each of four physicians was asked to choose one of four strategies: (1) increase or decrease therapeutic pressure; (2) change nasal mask for oro-nasal mask/chinstrap; (3) favor a nonsupine or supine position; (4) no action for individual leak management. Subsequently, a meeting was held to determine a consensus choice for each individual case. RESULTS Seventy-eight consecutive patients underwent home-polygraphy with Somnolter. Fifty recordings were analyzed (16 females; 65 [57-75] years of age; BMI = 31.1 [27.4-35.3]). Individual diagnosis of UL was routinely feasible. The determinants of UL were heterogeneous in the population, and diagnosis of UL was not feasible in 10 patients. Based on the results from this analysis, we established consensus leak management strategies at the individual level. The average Cohen κ coefficient for the four raters was 0.58. Pressure modification was proposed in 36% of patients, no action in 24%, installation of a facial mask/chinstrap in 22%, and positional treatment in 18%. INTERPRETATION The use of type 3 polygraphy for characterizing leak determinants in patients treated with nasal automatic-CPAP is feasible in routine practice. Leak determinants are patient specific. Interrater concordance for determining individual leak management strategies demonstrated a "fair" level of agreement. TRIAL REGISTRY ClinicalTrials.gov; No.: NCT03381508; URL: www.clinicaltrials.gov).
Collapse
Affiliation(s)
- Marius Lebret
- University of Grenoble Alpes, Grenoble, France; AGIR à dom. Association, Meylan, France.
| | - Dany Jaffuel
- APARD, groupe Adène, Montpellier, France; Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, Montpellier, France; Pulmonary Disorders and Respiratory Sleep Disorders Unit, Polyclinic Saint-Privat, Boujan sur Libron, France
| | - Carey M Suehs
- Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, Montpellier, France
| | - Jean-Pierre Mallet
- Department of Respiratory Diseases, Montpellier University Hospital, Arnaud de Villeneuve Hospital, Montpellier, France
| | | | - Marie-Caroline Rotty
- APARD, groupe Adène, Montpellier, France; IMAG, CNRS, Montpellier University, Montpellier University Hospital, Montpellier, France
| | - Jean-Louis Pépin
- University of Grenoble Alpes, Grenoble, France; Sleep Laboratory, Thorax and Vessels Division, Grenoble Alpes University Hospital, France
| | | | - Nicolas Molinari
- IMAG, CNRS, Montpellier University, Montpellier University Hospital, Montpellier, France
| | - Jean-Christian Borel
- University of Grenoble Alpes, Grenoble, France; AGIR à dom. Association, Meylan, France; Sleep Laboratory, Thorax and Vessels Division, Grenoble Alpes University Hospital, France
| |
Collapse
|
43
|
Prigent A, Gentina T, Launois S, Meurice JC, Pia d'Ortho M, Philippe C, Tamisier R, Gagnadoux F, Jaffuel D. [Telemonitoring in continuous positive airway pressure-treated patients with obstructive sleep apnoea syndrome: An algorithm proposal]. Rev Mal Respir 2020; 37:550-560. [PMID: 32402599 DOI: 10.1016/j.rmr.2020.04.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 12/20/2019] [Indexed: 12/19/2022]
Abstract
Most of the continuous positive airway pressure (CPAP) devices currently in use allow telemonitoring of observance, leaks and the apnoea-hypopnoea index (AHI). La Société française de recherche et de médecine du sommeil (SFRMS) and La Société de pneumologie de langue française (SPLF) workgroup offer to CPAP prescribers and to home care providers a scientific document which has the following purposes: to underline the relevance of the telemonitoring of leaks and the AHI, to define alert thresholds, to describe the principal mechanisms generating excessive leaks and high AHI, and to propose a diagnostic algorithm.
Collapse
Affiliation(s)
- A Prigent
- Groupe médical de pneumologie, polyclinique Saint-Laurent, 35000 Rennes, France.
| | - T Gentina
- Centre CESAL groupe Ramsay générale de Santé, hôpital privé Louvière, Lille, France
| | - S Launois
- CEREVES Paris Jean-Jaurès, hôpital Jean-Jaurès, 75019 Paris, France
| | - J C Meurice
- Département de pneumologie, CHU de Poitiers, Poitiers, France
| | - M Pia d'Ortho
- NeuroDiderot, Inserm, université de Paris, 75019 Paris, France; Département de physiologie - explorations fonctionnelles, hôpital Bichat, AP-HP, 75018 Paris, France
| | - C Philippe
- Unité des pathologies du sommeil, groupe hospitalier Pitié-Salpêtrière, Paris, France
| | - R Tamisier
- Inserm, HP2, université Grenoble Alpes, CHU Grenoble Alpes, 38000 Grenoble, France
| | - F Gagnadoux
- Département de pneumologie et médecine du sommeil, CHU d'Angers, Angers, France; Inserm UMR 1063, université d'Angers, Angers, France
| | - D Jaffuel
- Département des maladies respiratoires, hôpital Arnaud-de-Villeneuve, CHU de Montpellier, 34000 Montpellier, France; Unité des maladies respiratoires/troubles respiratoires du sommeil, polyclinique Saint-Privat, 34760 Boujan-sur-Libron, France
| | | |
Collapse
|
44
|
Yui MS, Tominaga Q, Lopes BCP, Eckeli AL, Rabelo FAW, Küpper DS, Valera FCP. Nasal vs. oronasal mask during PAP treatment: a comparative DISE study. Sleep Breath 2019; 24:1129-1136. [PMID: 31797217 DOI: 10.1007/s11325-019-01976-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 11/02/2019] [Accepted: 11/12/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE The present study evaluated the upper airway pattern of obstruction in individuals undergoing drug-induced sleep endoscopy (DISE) exam with positive airway pressure (PAP), and compared this effect through a nasal or oronasal mask. METHODS Prospective study. Patients requiring PAP due to obstructive sleep apnea (OSA) were evaluated through DISE at three different moments: (1) a baseline condition (without PAP); (2) PAP treatment with a nasal mask; and (3) PAP with an oronasal mask at the same pressure. The conditions were compared intra-individually, following VOTE classification. A TOTAL VOTE score (the sum of VOTE scores observed for each anatomical site) was also applied to compare intra-individual results. RESULTS Thirteen patients were enrolled in the study. All patients presented multi-level pharyngeal obstruction at baseline condition. In six patients, the pattern of obstruction differed according to the mask. Nasal mask significantly decreased the obstruction score when compared with baseline condition both in velum (P value < 0.05) and oropharynx regions (P value < 0.005). TOTAL VOTE score was also significantly lower during nasal mask evaluation when compared with basal condition (P value < 0.005). Remarkably, oronasal mask with the same pressure was not as effective as nasal masks. Obstruction levels observed at the tongue base or epiglottis levels were more resistant to PAP treatment. CONCLUSIONS Collapse in velum and oropharyngeal sites is more compliant to PAP than obstruction at lower levels of the pharynx, either with nasal or oronasal masks. Nasal mask is superior to prevent pharyngeal collapse than oronasal devices under the same pressure.
Collapse
Affiliation(s)
- Mariane S Yui
- ENT Division, Clinics Hospital, Medical School of Ribeirão Preto, University of São Paulo, Av. Bandeirantes, 3900-12o andar, Ribeirão Preto-São Paulo, CEP 14049-900, Brazil
| | - Quedayr Tominaga
- ENT Division, Clinics Hospital, Medical School of Ribeirão Preto, University of São Paulo, Av. Bandeirantes, 3900-12o andar, Ribeirão Preto-São Paulo, CEP 14049-900, Brazil
| | - Bruno C P Lopes
- Anesthesiology Division, Clinics Hospital, Medical School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Alan L Eckeli
- Neurosciences Department, Clinics Hospital, Medical School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | | | - Daniel S Küpper
- ENT Division, Clinics Hospital, Medical School of Ribeirão Preto, University of São Paulo, Av. Bandeirantes, 3900-12o andar, Ribeirão Preto-São Paulo, CEP 14049-900, Brazil
| | - Fabiana C P Valera
- ENT Division, Clinics Hospital, Medical School of Ribeirão Preto, University of São Paulo, Av. Bandeirantes, 3900-12o andar, Ribeirão Preto-São Paulo, CEP 14049-900, Brazil.
| |
Collapse
|
45
|
Practical Aspects of Interface Application in CPAP Treatment. Can Respir J 2019; 2019:7215258. [PMID: 31781315 PMCID: PMC6874967 DOI: 10.1155/2019/7215258] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 08/01/2019] [Indexed: 02/07/2023] Open
Abstract
While continuous positive airway pressure (CPAP) is an effective first-line therapy for sleep apnea, CPAP fails in one third of patients mainly due to poor adherence to the CPAP device and masks. The role of the medical team is to guide the patient in choosing the best mask, thus insuring good CPAP therapy adherence. Once a suitable mask is found, the brand of the mask does not affect patient satisfaction or CPAP adherence. For the majority of patients, nasal masks are by far more suitable than oronasal masks. Orosanal masks are indicated in case of nasal stuffiness or when an air leak manifests through the mouth. Re-evaluation of the efficacy of CPAP therapy is recommended when switching to oronasal masks.
Collapse
|
46
|
Nascimento JA, Genta PR, Fernandes PHS, Barroso LP, Carvalho TS, Moriya HT, Madeiro F, Lorenzi-Filho G, Nakagawa NK. Predictors of oronasal breathing among obstructive sleep apnea patients and controls. J Appl Physiol (1985) 2019; 127:1579-1585. [PMID: 31465714 DOI: 10.1152/japplphysiol.00964.2018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Oronasal breathing may adversely impact obstructive sleep apnea (OSA) patients either by increasing upper airway collapsibility or by influencing continuous positive airway pressure (CPAP) treatment outcomes. Predicting a preferential breathing route would be helpful to guide CPAP interface prescription. We hypothesized that anthropometric measurements but not self-reported oronasal breathing are predictors of objectively measured oronasal breathing. Seventeen OSA patients and nine healthy subjects underwent overnight polysomnography with an oronasal mask with two sealed compartments attached to independent pneumotacographs. Subjects answered questionnaires about nasal symptoms and perceived breathing route. Oronasal breathing was more common (P = <0.001) among OSA patients than controls while awake (62 ± 44 vs. 5 ± 6%) and during sleep (59 ± 39 vs. 25 ± 21%, respectively). Oronasal breathing was associated with OSA severity (P = 0.009), age (P = 0.005), body mass index (P = 0.044), and neck circumference (P = 0.004). There was no agreement between objective measurement and self-reported breathing route among OSA patients while awake (κ = -0.12) and asleep (κ = -0.02). The breathing route remained unchanged after 92% of obstructive apneas. These results suggest that oronasal breathing is more common among OSA patients than controls during both wakefulness and sleep and is associated with OSA severity and anthropometric measures. Self-reporting is not a reliable predictor of oronasal breathing and should not be considered an indication for oronasal CPAP.NEW & NOTEWORTHY Continuous positive airway pressure (CPAP) interface choice for obstructive sleep apnea (OSA) patients is often guided by nasal symptoms and self-reported breathing route. We showed that oronasal breathing can be predicted by anthropometric measurements and OSA severity but not by self-reported oronasal breathing. Self-reported breathing and nasal symptoms should not be considered for CPAP interface choice.
Collapse
Affiliation(s)
- Juliana A Nascimento
- Department of Physiotherapy, LIM-54, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil.,Sleep Laboratory, Pulmonary Division, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Pedro R Genta
- Sleep Laboratory, Pulmonary Division, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Paulo H S Fernandes
- Sleep Laboratory, Pulmonary Division, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Lucia P Barroso
- Departament of Statistics, Instituto de Matemática e Estatística da Universidade de São Paulo, São Paulo, Brazil
| | - Tômas S Carvalho
- Department of Physiotherapy, LIM-54, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil.,Sleep Laboratory, Pulmonary Division, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Henrique T Moriya
- Biomedical Engineering Laboratory, Telecommunication and Control Engineering Department, Escola Politécnica da Universidade de São Paulo, São Paulo, Brazil
| | - Fernanda Madeiro
- Sleep Laboratory, Pulmonary Division, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Geraldo Lorenzi-Filho
- Sleep Laboratory, Pulmonary Division, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Naomi Kondo Nakagawa
- Department of Physiotherapy, LIM-54, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil.,Sleep Laboratory, Pulmonary Division, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| |
Collapse
|
47
|
Genta PR, Lorenzi-Filho G. Sealing the Leak: A Step Forward in Improving CPAP Adherence. Chest 2019; 153:774-775. [PMID: 29626967 DOI: 10.1016/j.chest.2017.10.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 10/19/2017] [Accepted: 10/20/2017] [Indexed: 11/15/2022] Open
Affiliation(s)
- Pedro R Genta
- Pulmonary Division, Heart Institute (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, São Paulo, Brazil
| | - Geraldo Lorenzi-Filho
- Pulmonary Division, Heart Institute (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, São Paulo, Brazil.
| |
Collapse
|
48
|
Comparison of Auto- and Fixed-Continuous Positive Airway Pressure on Air Leak in Patients with Obstructive Sleep Apnea: Data from a Randomized Controlled Trial. Can Respir J 2019; 2019:6310956. [PMID: 31485282 PMCID: PMC6702837 DOI: 10.1155/2019/6310956] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2019] [Revised: 06/23/2019] [Accepted: 07/10/2019] [Indexed: 11/18/2022] Open
Abstract
Auto-CPAP may cause sleep fragmentation due to variations in pressure and unintentional leaks. The aim of this study was to compare air leak between fixed-CPAP and auto-CPAP after 4 months of CPAP treatment. This study is an ancillary analysis of a randomized, double-blind, parallel, controlled trial over 4 months, comparing fixed- and auto-CPAP in newly diagnosed patients with OSA. The following data were extracted from the CPAP devices: mean and 90th percentile pressure, residual apnea-hypopnea index, mean CPAP use, and amount of leak. Within each arm, patients were also randomly allocated to use of one of the three different brands of devices. Since the leak was reported differently for each device, median leak value was determined for each brand and leaks were classified as “above the median” or “below the median”. Data from 269 patients were analyzed. The univariate analysis showed that tobacco consumption, CPAP level, and oronasal masks were associated with leaks above the median value but not the type of CPAP. The multivariate analysis showed that only CPAP level and oronasal masks were associated with leaks below the median. There were no differences in the types of mask used between fixed- and auto-CPAP. There was no impact of the type of CPAP on leaks or the type of interface used. We used a method based on the median leak value to standardize comparisons across devices which report leaks with different definitions.
Collapse
|
49
|
Foellner S, Guth P, Jorde I, Lücke E, Ganzert C, Stegemann-Koniszewski S, Schreiber J. Prevention of leakage due to mouth opening through applying an oral shield device (Sominpax™) during nasal CPAP therapy of patients with obstructive sleep apnea. Sleep Med 2019; 66:168-173. [PMID: 31884409 DOI: 10.1016/j.sleep.2019.06.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 06/22/2019] [Accepted: 06/24/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND/OBJECTIVE The first line treatment for obstructive sleep apnea (OSA) is nasal continuous positive airway pressure (nCPAP), for which a variety of masks are available. While nasal masks (NM) are the first choice; oronasal masks (ONM) are also frequently used to prevent mouth dryness resulting from mouth opening. Our cross-sectional, prospective, randomized, un-blinded study addressed the efficacy of wearing an oral shield in addition to NM in preventing mouth leakage METHODS: Patients with OSA and established therapy using NM and complaining about mouth dryness (n = 29) underwent three polysomnographies (PSGs) using NM, ONM or a nose mask in combination with an oral shield (NMS). Mask leakage was continuously documented and objective sleep quality was assessed. RESULTS There were significant differences in the apnea-hypopnea-index (AHI) between ONM (8.5/h; SD 6,7) and NM/nasal mask combined with oral shield device (NMS) (2.6/h; SD 2,3; 2.7/h; SD 2,6) (p < 0,05) as well as in leakage [ONM (39.7 l/min SD 12,4); NM (34.6 l/min SD 9,4); NMS (33.1 l/min SD 9,6)] (p = 0.011). Furthermore, analysis of sleep quality (NREM3) favored NM and NMS over ONM (p = 0.02). There were no significant differences between NM and NMS in any objective outcome. CONCLUSIONS Our data consistently confirmed the NM as the first choice for continuous positive airway pressure (CPAP) therapy of OSA. Notably, we demonstrated a high potential of the oral shield for patients with mouth opening to achieve additional comfort and thereby possibly compliance, without affecting nCPAP therapy effectiveness.
Collapse
Affiliation(s)
- Sebastian Foellner
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany.
| | - Patricia Guth
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Ilka Jorde
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Eva Lücke
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Christine Ganzert
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Sabine Stegemann-Koniszewski
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| | - Jens Schreiber
- Otto - von - Guericke University Magdeburg, Dept. of Pneumonology, Centre for Sleep Medicine, Magdeburg, Germany
| |
Collapse
|
50
|
Bailly S, Daabek N, Jullian-Desayes I, Joyeux-Faure M, Sapène M, Grillet Y, Borel JC, Tamisier R, Pépin JL. Partial failure of CPAP treatment for sleep apnoea: Analysis of the French national sleep database. Respirology 2019; 25:104-111. [PMID: 31336407 DOI: 10.1111/resp.13650] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 06/03/2019] [Accepted: 06/11/2019] [Indexed: 01/01/2023]
Abstract
BACKGROUND AND OBJECTIVE Continuous positive airway pressure (CPAP) is the first-line therapy for obstructive sleep apnoea (OSA). Residual apnoea and/or hypopnoea events, that is an apnoea-hypopnoea index (AHI) > 5, during CPAP contribute to treatment drop-out. The clinical scenarios triggering residual events during CPAP use are poorly described. Underlying co-morbidities, especially cardiovascular diseases, lifestyle factors, OSA characteristics at diagnosis and type of mask have been suggested as potential contributors. METHODS Patients from the prospective French sleep apnoea registry diagnosed with OSA (AHI ≥ 15 events/h) treated with CPAP were included. Logistic regression analysis identified factors associated with a risk of residual AHI > 5 events/h on CPAP. RESULTS The 12 285 OSA patients were predominantly men (n = 8715, 70.9%), middle-aged (58.2 (49.8; 66.1) years) and obese (median body mass index: 31.3 (27.7; 35.6) kg/m2 ). Most had an AHI ≤ 5 events/h (n = 9573, 77.9%) versus 22.1% with AHI > 5/h. The latter were less CPAP adherent (5.75 (4.01; 7.00) vs 6.00 (4.53; 7.00) h/night). In multivariable analysis, factors associated with residual AHI >5/h were male sex, age, sedentary lifestyle, OSA severity, cardiovascular co-morbidities (heart failure and arrhythmia) and type of interface (orofacial mask versus nasal mask: OR = 2.15 (95%CI: 1.95; 2.37)). A subgroup analysis found that patients using pressures above 10 cm H2 O were 1.43 (95% CI: 1.3; 1.57) times more likely to have residual AHI > 5/h. CONCLUSION Knowing about risk factors for residual apnoeic-hypopnoeic events may assist in the timely provision of personalized care including the type of PAP therapy, attention to co-morbidities and choice of interface.
Collapse
Affiliation(s)
- Sébastien Bailly
- HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France.,EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France
| | - Najeh Daabek
- HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France.,AGIR à dom, Non-Profit Homecare Organisation, Meylan, France
| | - Ingrid Jullian-Desayes
- HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France.,EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France
| | - Marie Joyeux-Faure
- HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France.,EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France
| | - Marc Sapène
- Private Practice Sleep and Respiratory Disease Centre, Nouvelle Clinique Bel Air, Bordeaux, France
| | - Yves Grillet
- Private Practice Sleep and Respiratory Disease Centre, Valence, France
| | - Jean-Christian Borel
- HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France.,EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France.,AGIR à dom, Non-Profit Homecare Organisation, Meylan, France
| | - Renaud Tamisier
- HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France.,EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France
| | - Jean-Louis Pépin
- HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France.,EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France
| |
Collapse
|