1
|
Adedokun TA, Kwaghe VG, Adedokun O, Badru T, Odili AN, Alfa J, Kolade-Yunusa HO, Ojji DB. Prevalence and risk factors for subclinical atherosclerosis amongst adults living with HIV in University of Abuja Teaching Hospital, Gwagwalada. FRONTIERS IN REPRODUCTIVE HEALTH 2023; 5:1092211. [PMID: 36819143 PMCID: PMC9935581 DOI: 10.3389/frph.2023.1092211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 01/10/2023] [Indexed: 02/05/2023] Open
Abstract
Background Subclinical atherosclerosis characterizes cardiovascular diseases (CVD), and Human Immunodeficiency Virus (HIV) infection and antiretroviral therapy (ART) are identified risk factors for atherosclerosis. Meanwhile, data on HIV and atherosclerosis in Nigeria are limited. Objectives We sought to estimate the prevalence of subclinical atherosclerosis and associated risk factors amongst adult persons living with HIV/AIDS (PLHIV) enrolled at University of Abuja Teaching Hospital, Gwagwalada, Abuja (UATH). Methods This was a cross-sectional study of 277 consecutively selected PLHIV ≥18 years enrolled for HIV care and treatment at UATH. Pretested structured questionnaire was used to collect data from consenting ART-experienced and ART-naïve patients on risk factors of atherosclerosis. Carotid intima media thickness (CIMT) ≥0.71 mm as measured by Doppler ultrasonography was used to identify patients with sub-clinical atherosclerosis. Two logistic regression models with (Model-A) and without (Model-B) traditional risk factors were fitted to identify risk factors of subclinical atherosclerosis. Results Participants' mean age was 39.44 ± 10.71 years with female preponderance (64.26%). Overall prevalence of subclinical atherosclerosis was 43.32% (62.25% in ART-experienced). Model-A identified male sex [AOR 4.33(1.74-10.76), p = 0.002], advancing age [30-39 years AOR 5.95(1.31-26.96), p = 0.021]; ≥40 years AOR 19.51(4.30-88.56), p ≤ 0.001), advancing HIV infection [≥WHO stage II AOR 4.19(1.11-15.92), p = 0.035], hypercholesterolemia [AOR 3.88(1.47-10.25), p ≤ 0.001] and ≥5 year duration on ART [AOR 9.05(3.16-25.92), p ≤ 0.001] as risk factors of subclinical atherosclerosis. In Model-B (excluding traditional risk factors) on the other hand, advancing HIV infection [≥WHO stage II AOR 3.93(1.19-13.042), p = 0.025] and duration on ART [≥5 years AOR 11.43(4.62-28.29), p = 0.001] were found as risk factors of subclinical atherosclerosis. Conclusion Subclinical atherosclerosis was higher in ART-experienced patients, and this was irrespective of presence or absence of traditional risk factors. And advancing HIV disease and duration on ART were found as significant risk factors for subclinical atherosclerosis. We therefore recommend routine CVD risk screening in PLHIV.
Collapse
Affiliation(s)
- Taiwo A. Adedokun
- Department of Internal Medicine, University of Abuja Teaching Hospital, Gwagwalada, FCT, Nigeria,Correspondence: Taiwo A. Adedokun
| | - Vivian G. Kwaghe
- Department of Internal Medicine, University of Abuja Teaching Hospital, Gwagwalada, FCT, Nigeria
| | - Oluwasanmi Adedokun
- Center for International Health, Education, and Biosecurity (Ciheb), Maryland Global Initiatives Corporation (MGIC) - an Affiliate of University of Maryland Baltimore, Abuja, Nigeria
| | - Titilope Badru
- Strategic Information Department, FHI360, Abuja, Nigeria
| | - Augustine N. Odili
- Department of Internal Medicine, University of Abuja Teaching Hospital, Gwagwalada, FCT, Nigeria
| | - Jacob Alfa
- Department of Internal Medicine, University of Abuja Teaching Hospital, Gwagwalada, FCT, Nigeria
| | - Hadijat O. Kolade-Yunusa
- Department of Internal Medicine, University of Abuja Teaching Hospital, Gwagwalada, FCT, Nigeria
| | - Dike B. Ojji
- Department of Internal Medicine, University of Abuja Teaching Hospital, Gwagwalada, FCT, Nigeria
| |
Collapse
|
2
|
Adams P, Vancutsem E, Nicolaizeau C, Servais JY, Piérard D, François JH, Schneider T, Paxinos EE, Marins EG, Canchola JA, Seguin-Devaux C. Multicenter evaluation of the cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system for the quantification of HIV-1 plasma viral load. J Clin Virol 2019; 114:43-49. [PMID: 30991164 DOI: 10.1016/j.jcv.2019.03.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 03/07/2019] [Accepted: 03/11/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND AND OBJECTIVES Measurement of HIV-1 viral load (VL) is necessary to monitor treatment efficacy in patients receiving antiretroviral therapy. We evaluated the performance of the cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system ("cobas 4800 HIV-1"). METHODS Limit of detection, linearity, accuracy, precision, and specificity of cobas 4800 HIV-1, COBAS® AmpliPrep/COBAS® Taqman® HIV-1 version 2.0 (CAP/CTM HIV-1 v2) and Abbott RealTime HIV-1 were determined in one or two out of three sites. RESULTS The limit of detection of the cobas 4800 HIV-1 for 400 μL and 200 μL input volumes was 14.2 copies/mL (95% CI: 12.5-16.6 copies/mL) and 43.9 copies/mL (37.7-52.7 copies/mL), respectively. Cobas 4800 HIV-1 demonstrated 100% specificity, and results were linear for all analyzed group M HIV-1 subtypes. Precision was high (SD < 0.19 log10) across all measured ranges, reagent lots and input volumes. Correlation between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 or RealTime HIV-1 was high (R2 ≥ 0.95). Agreement between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 was 96.5% (95.0%-97.7%) at a threshold of 50 copies/mL, and 97.2% (95.8%-98.3%) at 200 copies/mL. Agreement between cobas 4800 HIV-1 and RealTime HIV-1 was 96.6% (93.4%-98.5%) at 50 copies/mL, and 97.0% (94.0%-98.8%) at 200 copies/mL. The mean difference between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 or RealTime HIV-1 was -0.10 log10 or 0.01 log10, respectively. CONCLUSIONS The cobas 4800 HIV-1 test is highly sensitive, accurate and correlated well with other assays, including agreement around clinically relevant thresholds, indicating minimal overall VL quantification differences between tested platforms.
Collapse
Affiliation(s)
- Phillip Adams
- Department of Infection and Immunity, Luxembourg Institute of Health, Luxembourg
| | - Ellen Vancutsem
- AIDS Reference Laboratory, Dept. Microbiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Cyrielle Nicolaizeau
- Department of Infection and Immunity, Luxembourg Institute of Health, Luxembourg
| | - Jean-Yves Servais
- Department of Infection and Immunity, Luxembourg Institute of Health, Luxembourg
| | - Denis Piérard
- AIDS Reference Laboratory, Dept. Microbiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | | | | | | | - Ed G Marins
- Roche Molecular Systems, Pleasanton, CA, USA
| | | | - Carole Seguin-Devaux
- Department of Infection and Immunity, Luxembourg Institute of Health, Luxembourg.
| |
Collapse
|
3
|
Farzan VM, Kvach MV, Aparin IO, Kireev DE, Prikazchikova TA, Ustinov AV, Shmanai VV, Shipulin GA, Korshun VA, Zatsepin TS. Novel homo Yin-Yang probes improve sensitivity in RT-qPCR detection of low copy HIV RNA. Talanta 2019; 194:226-232. [DOI: 10.1016/j.talanta.2018.10.043] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2018] [Revised: 10/09/2018] [Accepted: 10/11/2018] [Indexed: 12/31/2022]
|
4
|
Noorbazargan H, Nadji SA, Mirab Samiee S, Paryan M, Mohammadi-Yeganeh S. Comparison of a new in-house HIV-1 TaqMan real-time PCR and three commercial HIV-1 RNA quantitative assays. Comp Immunol Microbiol Infect Dis 2018; 59:1-7. [PMID: 30290882 DOI: 10.1016/j.cimid.2018.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Revised: 07/03/2018] [Accepted: 09/04/2018] [Indexed: 10/28/2022]
Abstract
OBJECTIVES The aim of this study was to compare the analytical performance of an In-House HIV-1 viral load determination technique with three commercial kits including COBAS® AmpliPrep, RealStar®, and RTA® HIV-1 Real-Time PCR. RESULTS A total of 100 HIV-1 suspicious plasma samples were tested by the In-House TaqMan® Real-Time PCR assay along with the above-mentioned kits. Comparative analysis between In-House and reference method (COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Test version 2.0) showed high concordance with a mean difference of 0.08 log10 copies/ml. All samples results were within -0.16-0.31 log10 copies/ml. A suitable correlation was obtained with a coefficient (R2) of 0.82 between the In-House assay and RTA® Kit, however, two positive samples were not detected. The lowest agreement was detected with RealStar® HIV Kit 1.0 (R2 = 0.49, r = 0.7). CONCLUSIONS The newly developed method has suitable sensitivity, accuracy, and precision. In addition, it is cost-effective and can be an alternative in all laboratories.
Collapse
Affiliation(s)
- Hassan Noorbazargan
- Department of Biotechnology, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Seyed Alireza Nadji
- Virology Research Center (VRC), National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | | | - Mahdi Paryan
- Department of Research and Development, Production and Research Complex, Pasteur Institute of Iran, Tehran, Iran.
| | - Samira Mohammadi-Yeganeh
- Cellular and Molecular Biology Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Department of Biotechnology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
5
|
Leierer G, Grabmeier-Pfistershammer K, Steuer A, Sarcletti M, Geit M, Haas B, Taylor N, Kanatschnig M, Rappold M, Ledergerber B, Zangerle R. A Single Quantifiable Viral Load Is Predictive of Virological Failure in Human Immunodeficiency Virus (HIV)-Infected Patients on Combination Antiretroviral Therapy: The Austrian HIV Cohort Study. Open Forum Infect Dis 2016; 3:ofw089. [PMID: 27419163 PMCID: PMC4943568 DOI: 10.1093/ofid/ofw089] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Accepted: 04/29/2016] [Indexed: 01/13/2023] Open
Abstract
Background. Viral loads (VLs) detectable at low levels are not uncommon in patients on combination antiretroviral therapy (cART). We investigated whether a single quantifiable VL predicted virological failure (VF). Methods. We analyzed patients receiving standard regimens with at least 1 VL measurement below the limit of quantification (BLQ) in their treatment history. The first VL measurement after 6 months of unmodified cART served as baseline VL for the subsequent analyses of the time to reach single VL levels of ≥200, ≥400, and ≥1000 copies/mL. Roche TaqMan 2.0 was used to quantify human immunodeficiency virus-1 ribonucleic acid. Factors associated with VF were determined by Cox proportional hazards models. Results. Of 1614 patients included in the study, 68, 44, and 34 experienced VF ≥200, ≥400, and ≥1000 copies/mL, respectively. In multivariable analyses, compared with patients who were BLQ, a detectable VL ≤ 50 and VL 51-199 copies/mL predicted VF ≥ 200 copies/mL (hazards ratio [HR] = 2.19, 95% confidence interval [CI] = 1.06-4.55 and HR = 4.21, 95% CI = 2.15-8.22, respectively). In those with VL 51-199 copies/mL, a trend for an increased risk of VF ≥400 and VF ≥1000 copies/mL could be found (HR = 2.13, 95% CI = 0.84-5.39 and HR = 2.52, 95% CI = 0.96-6.60, respectively). Conclusions. These findings support closer monitoring and adherence counseling for patients with a single measurement of quantifiable VL <200 copies/mL.
Collapse
Affiliation(s)
- Gisela Leierer
- Department of Dermatology and Venereology, Medical University of Innsbruck,; Austrian HIV Cohort Study, Innsbruck
| | | | | | - Mario Sarcletti
- Department of Dermatology and Venereology , Medical University of Innsbruck
| | - Maria Geit
- Department of Dermatology , General Hospital Linz
| | - Bernhard Haas
- Department of Internal Medicine , General Hospital Graz-West
| | - Ninon Taylor
- Department of Internal Medicine III With Hematology, Medical Oncology, Hemostaseology, Infectious Diseases, Rheumatology , Oncologic Center, Laboratory for Immunological and Molecular Cancer Research, Paracelsus Medical University , Salzburg
| | | | - Michaela Rappold
- Department of Dermatology and Venereology, Medical University of Innsbruck,; Austrian HIV Cohort Study, Innsbruck
| | - Bruno Ledergerber
- Division of Infectious Diseases and Hospital Epidemiology , University Hospital Zurich, University of Zurich , Switzerland
| | - Robert Zangerle
- Department of Dermatology and Venereology , Medical University of Innsbruck
| |
Collapse
|
6
|
Nair SV, Kim HC, Fortunko J, Foote T, Peling T, Tran C, Nugent CT, Joo S, Kang Y, Wilkins B, Lednovich K, Worlock A. Aptima HIV-1 Quant Dx--A fully automated assay for both diagnosis and quantification of HIV-1. J Clin Virol 2016; 77:46-54. [PMID: 26896710 DOI: 10.1016/j.jcv.2016.02.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 01/29/2016] [Accepted: 02/02/2016] [Indexed: 10/22/2022]
Abstract
BACKGROUND Separate assays are available for diagnosis and viral load (VL) monitoring of HIV-1. Studies have shown that using a single test for both confirmatory diagnosis and VL increases linkage to care. OBJECTIVE To validate a single assay for both diagnosis and VL monitoring of HIV-1 on the fully automated Panther platform. STUDY DESIGN Validate the assay by assessing specificity, sensitivity, subtype detection, seroconversion, reproducibility and linearity. Also assess diagnostic agreement with the Procleix(®) Ultrio Elite™ discriminatory assay (Procleix), and agreement of VL results (method comparison) with Ampliprep/COBAS TaqMan HIV-1 version 2.0 (CAP/CTM), using clinical samples. RESULTS The assay was specific (100%) and sensitive with a 95% limit of detection of 12 copies/mL with the 3rd WHO standards. Aptima detected HIV in seroconversion panels 6 and 11 days before p24 antigen and antibody tests, respectively. Diagnostic agreement with Procleix, was 100%. Regression analysis showed good agreement of VL results between Aptima and CAP/CTM with a slope of 1.02, intercept of 0.07, and correlation coefficient (R(2)) of 0.97. Aptima was more sensitive than CAP/CTM. Equivalent quantification was seen on testing clinical samples and isolates belonging to HIV group M, N, O and P and commercially available subtype panels. Assay results were linear (R(2) 0.9994) with standard deviation of <0.17 log copies across assay range. CONCLUSIONS The good specificity, sensitivity, precision, subtype performance and clinical agreement with other assays demonstrated by Aptima combined with the complete automation provided by the Panther platform makes Aptima a good candidate for both VL monitoring and diagnosis of HIV-1.
Collapse
Affiliation(s)
| | | | | | | | | | - Cuong Tran
- Hologic Incorporated, San Diego, CA, USA
| | | | | | - Youna Kang
- Hologic Incorporated, San Diego, CA, USA
| | | | | | | |
Collapse
|
7
|
Leierer G, Grabmeier-Pfistershammer K, Steuer A, Geit M, Sarcletti M, Haas B, Kanatschnig M, Rappold M, Zangerle R, Ledergerber B, Taylor N. Factors Associated with Low-Level Viraemia and Virological Failure: Results from the Austrian HIV Cohort Study. PLoS One 2015; 10:e0142923. [PMID: 26566025 PMCID: PMC4643888 DOI: 10.1371/journal.pone.0142923] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Accepted: 10/28/2015] [Indexed: 12/20/2022] Open
Abstract
Background In human immunodeficiency virus treatment adequate virological suppression is warranted, nevertheless for some patients it remains a challenge. We investigated factors associated with low-level viraemia (LLV) and virological failure (VF) under combined antiretroviral therapy (cART). Materials and Methods We analysed patients receiving standard regimens between 1st July 2012 and 1st July 2013 with at least one viral load (VL) measurement below the quantification limit (BLQ) in their treatment history. After a minimum of 6 months of unmodified cART, the next single VL measurement within 6 months was analysed. VF was defined as HIV RNA levels ≥200 copies/mL and all other quantifiable measurements were classified as LLV. Factors associated with LLV and VF compared to BLQ were identified by logistic regression models. Results Of 2276 participants, 1972 (86.6%) were BLQ, 222 (9.8%) showed LLV and 82 (3.6%) had VF. A higher risk for LLV and VF was shown in patients with cART interruptions and in patients with boosted PI therapy. The risk for LLV and VF was lower in patients from centres using the Abbott compared to the Roche assay to measure VL. A higher risk for LLV but not for VF was found in patients with a higher VL before cART [for >99.999 copies/mL: aOR (95% CI): 4.19 (2.07–8.49); for 10.000–99.999 copies/mL: aOR (95% CI): 2.52 (1.23–5.19)] and shorter cART duration [for <9 months: aOR (95% CI): 2.59 (1.38–4.86)]. A higher risk for VF but not for LLV was found in younger patients [for <30 years: aOR (95% CI): 2.76 (1.03–7.35); for 30–50 years: aOR (95% CI): 2.70 (1.26–5.79)], people originating from high prevalence countries [aOR (95% CI): 2.20 (1.09–4.42)] and in male injecting drug users [aOR (95% CI): 2.72 (1.38–5.34)]. Conclusions For both VF and LLV, factors associated with adherence play a prominent role. Furthermore, performance characteristics of the diagnostic assay used for VL quantification should also be taken into consideration.
Collapse
Affiliation(s)
- Gisela Leierer
- Department of Dermatology and Venereology, Medical University of Innsbruck, Innsbruck, Austria
- Austrian HIV Cohort Study, Innsbruck, Austria
- * E-mail: (NT); (GL)
| | | | - Andrea Steuer
- Otto-Wagner Hospital, Department of Pulmonology, Vienna, Austria
| | - Maria Geit
- Department of Dermatology, General Hospital Linz, Linz, Austria
| | - Mario Sarcletti
- Department of Dermatology and Venereology, Medical University of Innsbruck, Innsbruck, Austria
| | - Bernhard Haas
- Department of Internal Medicine, General Hospital Graz-West, Graz, Austria
| | | | - Michaela Rappold
- Department of Dermatology and Venereology, Medical University of Innsbruck, Innsbruck, Austria
- Austrian HIV Cohort Study, Innsbruck, Austria
| | - Robert Zangerle
- Department of Dermatology and Venereology, Medical University of Innsbruck, Innsbruck, Austria
| | - Bruno Ledergerber
- Division of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Ninon Taylor
- Department of Internal Medicine III with Hematology, Medical Oncology, Hemostaseology, Infectious Diseases, Rheumatology, Oncologic Center, Laboratory of Immunological and Molecular Cancer Research, Paracelsus Medical University, Salzburg, Austria
- * E-mail: (NT); (GL)
| | | |
Collapse
|
8
|
Young J, Rickenbach M, Calmy A, Bernasconi E, Staehelin C, Schmid P, Cavassini M, Battegay M, Günthard HF, Bucher HC. Transient detectable viremia and the risk of viral rebound in patients from the Swiss HIV Cohort Study. BMC Infect Dis 2015; 15:382. [PMID: 26392270 PMCID: PMC4578247 DOI: 10.1186/s12879-015-1120-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Accepted: 09/11/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Temporary increases in plasma HIV RNA ('blips') are common in HIV patients on combination antiretroviral therapy (cART). Blips above 500 copies/mL have been associated with subsequent viral rebound. It is not clear if this relationship still holds when measurements are made using newer more sensitive assays. METHODS We selected antiretroviral-naive patients that then recorded one or more episodes of viral suppression on cART with HIV RNA measurements made using more sensitive assays (lower limit of detection below 50 copies/ml). We estimated the association in these episodes between blip magnitude and the time to viral rebound. RESULTS Four thousand ninety-four patients recorded a first episode of viral suppression on cART using more sensitive assays; 1672 patients recorded at least one subsequent suppression episode. Most suppression episodes (87 %) were recorded with TaqMan version 1 or 2 assays. Of the 2035 blips recorded, 84 %, 12 % and 4 % were of low (50-199 copies/mL), medium (200-499 copies/mL) and high (500-999 copies/mL) magnitude respectively. The risk of viral rebound increased as blip magnitude increased with hazard ratios of 1.20 (95 % CI 0.89-1.61), 1.42 (95 % CI 0.96-2.19) and 1.93 (95 % CI 1.24-3.01) for low, medium and high magnitude blips respectively; an increase of hazard ratio 1.09 (95 % CI 1.03 to 1.15) per 100 copies/mL of HIV RNA. CONCLUSIONS With the more sensitive assays now commonly used for monitoring patients, blips above 200 copies/mL are increasingly likely to lead to viral rebound and should prompt a discussion about adherence.
Collapse
Affiliation(s)
- Jim Young
- Basel Institute for Clinical Epidemiology and Biostatistics, University Hospital Basel, Basel, Switzerland.
| | - Martin Rickenbach
- Institute of Social and Preventive Medicine, University of Lausanne, Lausanne, Switzerland.
| | - Alexandra Calmy
- Division of Infectious Diseases, University Hospital Geneva, Geneva, Switzerland.
| | - Enos Bernasconi
- Division of Infectious Diseases, Regional Hospital of Lugano, Lugano, Switzerland.
| | - Cornelia Staehelin
- Department of Infectious Diseases, Bern University Hospital and University of Bern, Bern, Switzerland.
| | - Patrick Schmid
- Division of Infectious Diseases and Hospital Epidemiology, Cantonal Hospital St. Gallen, St Gallen, Switzerland.
| | - Matthias Cavassini
- Division of Infectious Diseases, University Hospital Lausanne, Lausanne, Switzerland.
| | - Manuel Battegay
- Division of Infectious Diseases and Hospital Epidemiology, University Hospital Basel, Basel, Switzerland.
| | - Huldrych F Günthard
- Division of Infectious Diseases and Hospital Epidemiology, University Hospital and University of Zürich, Zurich, Switzerland.
| | - Heiner C Bucher
- Basel Institute for Clinical Epidemiology and Biostatistics, University Hospital Basel, Basel, Switzerland. .,Division of Infectious Diseases and Hospital Epidemiology, University Hospital Basel, Basel, Switzerland.
| | | |
Collapse
|
9
|
Hopkins M, Hau S, Tiernan C, Papadimitropoulos A, Chawla A, Beloukas A, Geretti AM. Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays. J Clin Virol 2015. [PMID: 26209380 DOI: 10.1016/j.jcv.2015.05.020] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Quantitative measurement of HIV-1 RNA levels in plasma ('viral load') plays a central role in clinical management. The choice of assay platform can influence results and treatment decisions. OBJECTIVE To compare the analytical performance of the new TMA-based Hologic Aptima(®) HIV-1 Quant Dx assay with that of three PCR-based assays: Abbott RealTime HIV-1, Qiagen Artus(®) HI Virus-1 QS-RGQ, and Roche CAP/CTM HIV-1 Test v2. STUDY DESIGN Assay performance was evaluated using Acrometrix HIV-1 RNA Standard panels; the 3rd WHO HIV-1 RNA International Standard (12-500 copies/ml; 6 dilutions; 9 replicates); and plasma samples from 191 HIV-positive patients. RESULTS Aptima showed high (>0.99) precision, accuracy and concordance with the Acrometrix Standards across a wide dynamic range (2.0-6.7 log10copies/ml). Variance caused up to 2.1 (Aptima), 1.7 (RealTime), 7.5 (Artus), and 1.9 (CAP/CTM) fold changes in the International Standard quantifications at 50-500 copies/ml. HIV-1 RNA detection rates in plasma samples were 141/191 (74%), 119/191 (62%), 108/191 (57%), and 145/191 (76%) for Aptima, RealTime, Artus and CAP/CTM, respectively. For categorising samples either side of 50 copies/ml, Aptima had excellent agreement with RealTime (kappa 0.92; 95% CI 0.87-0.98); lowest agreement was with Artus (kappa 0.79; 95%CI 0.70-0.88). Aptima quantifications were mean 0.12 and 0.06 log10copies/ml higher compared with RealTime and CAP/CTM, respectively, and 0.05 log10copies/ml lower compared with Artus. Limits of agreement were narrowest when comparing Aptima to RealTime. CONCLUSIONS The new Aptima HIV assay is sensitive, precise, and accurate. HIV assays exhibit discordance at low HIV-1 RNA copy numbers.
Collapse
Affiliation(s)
- Mark Hopkins
- Liverpool Clinical Laboratories, Liverpool, United Kingdom.
| | - Sarah Hau
- Liverpool Clinical Laboratories, Liverpool, United Kingdom
| | | | | | - Anu Chawla
- Liverpool Clinical Laboratories, Liverpool, United Kingdom
| | | | | |
Collapse
|
10
|
Muenchhoff M, Madurai S, Hempenstall AJ, Adland E, Carlqvist A, Moonsamy A, Jaggernath M, Mlotshwa B, Siboto E, Ndung'u T, Goulder PJR. Evaluation of the NucliSens EasyQ v2.0 assay in comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in quantification of C-clade HIV-1 in plasma. PLoS One 2014; 9:e103983. [PMID: 25157919 PMCID: PMC4144839 DOI: 10.1371/journal.pone.0103983] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Accepted: 07/04/2014] [Indexed: 01/16/2023] Open
Abstract
Human immunodeficiency virus type 1 (HIV-1) genetic diversity poses a challenge to reliable viral load monitoring. Discrepancies between different testing platforms have been observed, especially for non-clade-B virus. Therefore we compare, in antiretroviral therapy (ART)-naïve South African subjects predominantly infected with HIV-1 clade-C, three commercially available assays: the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test version 2.0 by Roche (CAP/CTM v2.0), the BioMérieux NucliSens Version 2.0 Easy Q/Easy Mag (NucliSens v2.0) and the Roche COBAS Amplicor HIV-1 Monitor Test Version 1.5 (Amplicor v1.5). Strong linear correlation was observed and Bland-Altman analyses showed overall good agreement between the assays with mean viral load differences of 0.078 log cp/ml (NucliSens v2.0 – Amplicor v1.5), 0.260 log cp/ml (CAP/CTM v2.0 – Amplicor v1.5) and 0.164 log cp/ml (CAP/CTM v2.0 – NucliSens v2.0), indicating lower mean viral load results for the Amplicor v1.5 and higher mean readings for the CAP/CTM v2.0. Consistent with observations following previous comparisons of CAP/CTM v2.0 versus Amplicor v1.5, the CAP/CTM v2.0 assay detected low-level viremia (median 65 cp/ml) in more than one-third of those in whom viremia had been undetectable (<20 cp/ml) in assays using the NucliSens platform. These levels of viremia are of uncertain clinical significance but may be of importance in early detection of ART resistance in those on treatment. Overall the three assays showed good comparability of results but with consistent, albeit relatively small, discrepancies for HIV-1 clade-C samples, especially in the low-viremic range that should be taken into account when interpreting viral load data.
Collapse
Affiliation(s)
- Maximilian Muenchhoff
- Department of Paediatrics, University of Oxford, Oxford, Oxfordshire, United Kingdom
- HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
| | - Savathee Madurai
- Global Clinical and Viral Laboratories, Amanzimtoti, KwaZulu-Natal, South Africa
| | | | - Emily Adland
- Department of Paediatrics, University of Oxford, Oxford, Oxfordshire, United Kingdom
| | - Anna Carlqvist
- Department of Paediatrics, University of Oxford, Oxford, Oxfordshire, United Kingdom
| | - Angeline Moonsamy
- HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
| | - Manjeetha Jaggernath
- HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
| | - Busisiwe Mlotshwa
- HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
| | - Emma Siboto
- HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
| | - Thumbi Ndung'u
- HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
- KwaZulu-Natal Research Institute for Tuberculosis and HIV (K-RITH), University of KwaZulu-Natal, Durban, South Africa
- Max Planck Institute for Infection Biology, Berlin, Berlin, Germany
- The Ragon Institute of Massachusetts General Hospital, Massachusetts Institute of Technology and Harvard University, Boston, Massachusetts, United States of America
| | - Philip Jeremy Renshaw Goulder
- Department of Paediatrics, University of Oxford, Oxford, Oxfordshire, United Kingdom
- HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
- The Ragon Institute of Massachusetts General Hospital, Massachusetts Institute of Technology and Harvard University, Boston, Massachusetts, United States of America
- * E-mail:
| |
Collapse
|
11
|
Amendola A, Marsella P, Bloisi M, Forbici F, Angeletti C, Capobianchi MR. Ability of two commercially available assays (Abbott RealTime HIV-1 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2.0) to quantify low HIV-1 RNA Levels (<1,000 copies/milliliter): comparison with clinical samples and NIBSC working reagent for nucleic acid testing assays. J Clin Microbiol 2014; 52:2019-26. [PMID: 24671791 PMCID: PMC4042785 DOI: 10.1128/jcm.00288-14] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2014] [Accepted: 03/21/2014] [Indexed: 11/20/2022] Open
Abstract
Concordance between molecular assays may be suboptimal at low HIV-1 viremia levels (<1,000 copies/ml); therefore, it may be difficult to define and compare virologic endpoints for successful and failed therapy. We compared two commercial assays (the Abbott RealTime HIV-1 and the Roche Cobas AmpliPrep/TaqMan HIV-1 version 2.0) for their ability to detect and quantify low viral loads. A comparison was performed using 167 residual clinical samples (with values ranging from "not detected" to 1,000 copies/ml, as measured by the Abbott assay) and the National Institute and Biological Standards and Control (NIBSC) HIV-1 RNA working reagent 1 for nucleic acid amplification techniques (NAT) assays (serially diluted to a range from 1 to 1,000 copies/ml). Quantitative results were compared using Lin's concordance correlation coefficient and a Bland-Altman plot. Concordance with the qualitative results was measured by Cohen's kappa statistic. With clinical samples, the degree of interassay concordance of the qualitative results at a 40-copies/ml HIV-1 RNA threshold was substantial (κ = 0.762); the correlation among the quantified samples was suboptimal (concordance correlation coefficient, 0.728; P < 0.0001); the mean difference of the values between the Roche and Abbott assays was 0.193 log10 copies/ml. Using the HIV-1 RNA working reagent 1 for NAT assays, the results provided by the Roche assay were, on average, 3 times higher than expected, while the Abbott assay showed high accuracy. The Roche assay was highly sensitive, being able to detect a level as low as 3.5 copies/ml HIV-1 RNA with 95% probability. The performance characteristics of each molecular assay should be taken into account when HIV-1 RNA threshold values for "virologic suppression," "virologic failure," "persistent low viral loads," etc., are defined and indicated in the support of clinical decisions.
Collapse
Affiliation(s)
| | - Patrizia Marsella
- National Institute for Infectious Diseases Lazzaro Spallanzani, Rome, Italy
| | - Maria Bloisi
- National Institute for Infectious Diseases Lazzaro Spallanzani, Rome, Italy
| | - Federica Forbici
- National Institute for Infectious Diseases Lazzaro Spallanzani, Rome, Italy
| | - Claudio Angeletti
- National Institute for Infectious Diseases Lazzaro Spallanzani, Rome, Italy
| | | |
Collapse
|
12
|
Swenson LC, Cobb B, Geretti AM, Harrigan PR, Poljak M, Seguin-Devaux C, Verhofstede C, Wirden M, Amendola A, Boni J, Bourlet T, Huder JB, Karasi JC, Zidovec Lepej S, Lunar MM, Mukabayire O, Schuurman R, Tomažič J, Van Laethem K, Vandekerckhove L, Wensing AMJ. Comparative performances of HIV-1 RNA load assays at low viral load levels: results of an international collaboration. J Clin Microbiol 2014; 52:517-23. [PMID: 24478482 PMCID: PMC3911321 DOI: 10.1128/jcm.02461-13] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Accepted: 11/26/2013] [Indexed: 11/20/2022] Open
Abstract
Low-level viremia during antiretroviral therapy and its accurate measurement are increasingly relevant. Here, we present an international collaboration of 4,221 paired blood plasma viral load (pVL) results from four commercial assays, emphasizing the data with low pVL. The assays compared were the Abbott RealTime assay, the Roche Amplicor assay, and the Roche TaqMan version 1 and version 2 assays. The correlation between the assays was 0.90 to 0.97. However, at a low pVL, the correlation fell to 0.45 to 0.85. The observed interassay concordance was higher when detectability was defined as 200 copies/ml than when it was defined as 50 copies/ml. A pVL of ∼100 to 125 copies/ml by the TaqMan version 1 and version 2 assays corresponded best to a 50-copies/ml threshold with the Amplicor assay. Correlation and concordance between the viral load assays were lower at a low pVL. Clear guidelines are needed on the clinical significance of low-level viremia.
Collapse
Affiliation(s)
- Luke C. Swenson
- BC Centre for Excellence in HIV/AIDS, Vancouver, British Columbia, Canada
| | - Bryan Cobb
- Roche Molecular Systems, Pleasanton, California, USA
| | - Anna Maria Geretti
- Institute of Infection and Global Health, University of Liverpool, United Kingdom
| | | | - Mario Poljak
- University of Ljubljana, Institute of Microbiology and Immunology, Ljubljana, Slovenia
| | | | | | - Marc Wirden
- AP-HP, Pitié-Salpêtrière Hospital, INSERM U 943, and Pierre et Marie Curie University Paris, Paris, France
| | - Alessandra Amendola
- Laboratory of Virology, National Institute for Infectious Diseases Lazzaro Spallanzani, Rome, Italy
| | - Jurg Boni
- Institute of Medical Virology, Swiss National Center for Retroviruses, University of Zurich, Zurich, Switzerland
| | - Thomas Bourlet
- Laboratory of Virology, CHU de Saint-Etienne, Saint-Etienne, France
| | - Jon B. Huder
- Institute of Medical Virology, Swiss National Center for Retroviruses, University of Zurich, Zurich, Switzerland
| | | | | | - Maja M. Lunar
- University of Ljubljana, Institute of Microbiology and Immunology, Ljubljana, Slovenia
| | | | - Rob Schuurman
- University Medical Center Utrecht, Utrecht, Netherlands
| | - Janez Tomažič
- University of Ljubljana, Institute of Microbiology and Immunology, Ljubljana, Slovenia
| | - Kristel Van Laethem
- Clinical and Epidemiological Virology, Rega Institute for Medical Research, KU Leuven, Leuven, Belgium
| | | | | |
Collapse
|