1
|
Beaumont AJ, Campbell AK, Unnithan VB, Oxborough D, Grace F, Knox A, Sculthorpe NF. The Influence of Age and Exercise Training Status on Left Ventricular Systolic Twist Mechanics in Healthy Males-An Exploratory Study. J Cardiovasc Dev Dis 2024; 11:321. [PMID: 39452291 PMCID: PMC11508667 DOI: 10.3390/jcdd11100321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 10/04/2024] [Accepted: 10/06/2024] [Indexed: 10/26/2024] Open
Abstract
Age-related differences in twist may be mitigated with exercise training, although this remains inconclusive. Moreover, temporal left ventricular (LV) systolic twist mechanics, including early-systolic (twistearly), and beyond peak twist (twistpeak) alone, have not been considered. Therefore, further insights are required to ascertain the influence of age and training status on twist mechanics across systole. Forty males were included and allocated into 1 of 4 groups based on age and training status: young recreationally active (YRA, n = 9; 28 ± 5 years), old recreationally active (ORA, n = 10; 68 ± 6 years), young trained (YT, n = 10; 27 ± 6 years), and old trained (OT, n = 11, 64 ± 4 years) groups. Two-dimensional speckle-tracking echocardiography was performed to determine LV twist mechanics, including twistearly, twistpeak, and total twist (twisttotal), by considering the nadir on the twist time-curve during early systole. Twisttotal was calculated by subtracting twistearly from their peak values. LV twistpeak was higher in older than younger men (p = 0.036), while twistpeak was lower in the trained than recreationally-active (p = 0.004). Twistpeak is underestimated compared with twisttotal (p < 0.001), and when early-systolic mechanics were considered, to calculate twisttotal, the age effect (p = 0.186) was dampened. LV twist was higher in older than younger age, with lower twist in exercise-trained than recreationally-active males. Twistpeak is underestimated when twistearly is not considered, with novel observations demonstrating that the age effect was dampened when considering twistearly. These findings elucidated a smaller age effect when early phases of systole are considered, while lower LV systolic mechanics were observed in older aged trained than recreationally-active males.
Collapse
Affiliation(s)
- Alexander J. Beaumont
- School of Science, Technology and Health, York St. John University, York YO31 7EX, UK;
| | - Amy K. Campbell
- School of Science, Technology and Health, York St. John University, York YO31 7EX, UK;
| | - Viswanath B. Unnithan
- Institute of Clinical Exercise and Health Sciences, School of Health and Life Sciences, University of the West of Scotland, Hamilton G72, 0LH, UK; (V.B.U.); (N.F.S.)
| | - David Oxborough
- Research Institute of Sport and Exercise Science, Liverpool John Moores University, Liverpool L3 3AF, UK;
| | - Fergal Grace
- Faculty of Health, School of Health Science and Psychology, Federation University Australia, Ballarat, VIC 3350, Australia;
| | - Allan Knox
- Exercise Science Department, California Lutheran University, Thousand Oaks, CA 91360, USA;
| | - Nicholas F. Sculthorpe
- Institute of Clinical Exercise and Health Sciences, School of Health and Life Sciences, University of the West of Scotland, Hamilton G72, 0LH, UK; (V.B.U.); (N.F.S.)
| |
Collapse
|
2
|
Hjertaas JJ, Einarsen E, Gerdts E, Kokorina M, Moen CA, Urheim S, Saeed S, Matre K. Impact of aortic valve stenosis on myocardial deformation in different left ventricular levels: A three-dimensional speckle tracking echocardiography study. Echocardiography 2023; 40:1028-1039. [PMID: 37543718 DOI: 10.1111/echo.15668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 07/05/2023] [Accepted: 07/27/2023] [Indexed: 08/07/2023] Open
Abstract
BACKGROUND Global systolic left ventricular (LV) myocardial function progressively declines as degenerative aortic valve stenosis (AS) progresses. Whether this results in uniformly distributed deformation changes from base to apex has not been investigated. METHODS Eighty-five AS patients underwent three-dimensional (3D) echocardiography in this cross-sectional study. Patients were grouped by peak jet velocity into mild (n = 32), moderate (n = 31), and severe (n = 22) AS. 3D speckle tracking derived strain, rotation, twist, and torsion were obtained to assess global LV function and myocardial function at the apical, mid, and basal levels. RESULTS Global longitudinal strain (GLS) was lower in patients with severe AS (-16.1 ± 2.4% in mild, -15.5 ± 2.5% in moderate, and -13.5 ± 3.0% in severe AS [all p < .01]). Peak basal and mid longitudinal strain (LS), basal rotation and twist from apical to basal level followed the same pattern, while peak apical LS was higher in moderate AS compared to severe AS (all p < .05). In multivariate analyses, lower GLS was particularly associated with male sex, higher body mass index and peak aortic jet velocity, lower basal LS with higher filling pressure (E/e') and LV mass, lower mid LS with higher RWT and presence of AS symptoms, and lower apical LS with male sex and higher systolic blood pressure, respectively (all p < .05). CONCLUSION Using 3D speckle tracking echocardiography reveals regional and global changes in LV mechanics in AS related to the severity of AS, LV remodeling and presence of cardiovascular risk factors.
Collapse
Affiliation(s)
| | - Eigir Einarsen
- Department of Clinical Science, University of Bergen, Bergen, Norway
| | - Eva Gerdts
- Department of Clinical Science, University of Bergen, Bergen, Norway
- Department of Heart Disease, Haukeland University Hospital, Bergen, Norway
| | - Marina Kokorina
- Department of Heart Disease, Haukeland University Hospital, Bergen, Norway
| | | | - Stig Urheim
- Department of Clinical Science, University of Bergen, Bergen, Norway
- Department of Heart Disease, Haukeland University Hospital, Bergen, Norway
| | - Sahrai Saeed
- Department of Heart Disease, Haukeland University Hospital, Bergen, Norway
| | - Knut Matre
- Department of Clinical Science, University of Bergen, Bergen, Norway
| |
Collapse
|
3
|
Al Saikhan L, Park C, Tillin T, Lloyd G, Mayet J, Chaturvedi N, Hughes AD. Relationship Between Image Quality and Bias in 3D Echocardiographic Measures: Data From the SABRE (Southall and Brent Revisited) Study. J Am Heart Assoc 2022; 11:e019183. [PMID: 35475343 PMCID: PMC9238620 DOI: 10.1161/jaha.120.019183] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Background Image‐quality (IQ) compromises left ventricle assessment by 3‐dimensional echocardiography (3DE). Sicker/frailer patients often have suboptimal IQ, and therefore observed associations may be biased by IQ. We investigated its effect in an observational study of older people and when IQ was modified experimentally in healthy volunteers. Methods and Results 3DE feasibility by IQ was assessed in 1294 individuals who attended the second wave of the Southall and Brent Revisited study and was compared with 2‐dimensional (2D)‐echocardiography feasibility in 147 individuals. Upon successful analysis, means of ejection fraction (3D‐EF) and global longitudinal strain (3D‐GLS) (plus 2D‐EF) were compared in individuals with poor versus good IQ. In 2 studies of healthy participants, 3DE‐IQ was impaired by (1) intentionally poor echocardiographic technique, and (2) use of a sheet of ultrasound‐attenuating material (neoprene rubber; 2–4 mm). The feasibility was 41% (529/1294) for 3DE versus 61% (89/147) for 2D‐EF, P<0.0001. Among acceptable images (n=529), good IQ by the 2015 American Society of Echocardiography/European Association of Cardiovascular Imaging criteria was 33.6% (178/529) and 71.3% (377/529) for 3D‐EF and 3D‐GLS, respectively. Individuals with poor IQ had lower 3D‐EF and 3D‐GLS (absolute) than those with good IQ (3D‐EF: 52.8±6.0% versus 55.7±5.7%, Mean‐Δ −2.9 [−3.9, 1.8]; 3D‐GLS: 18.6±3.2% versus 19.2±2.9%, Mean‐Δ −0.6 [−1.1, 0.0]). In 2 experimental models of poor IQ (n=36 for both), mean differences were (−2.6 to −3.2) for 3D‐EF and (−1.2 to −2.0) for 3D‐GLS. Similar findings were found for other 3DE left ventricle volumes and strain parameters. Conclusions 3DE parameters have low feasibility and values are systematically lower in individuals with poor IQ. Although 3D‐EF and 3D‐GLS have potential advantages over conventional echocardiography, further technical improvements are required to improve the utility of 3DE in clinical practice.
Collapse
Affiliation(s)
- Lamia Al Saikhan
- Department of Cardiac TechnologyCollege of Applied Medial SciencesImam Abdulrahman Bin Faisal UniversityDammamKingdom of Saudi Arabia
| | - Chloe Park
- MRC Unit for Lifelong Health and AgeingDepartment of Population Science & Experimental MedicineUCL Institute of Cardiovascular ScienceUniversity College LondonLondonUnited Kingdom
| | - Therese Tillin
- MRC Unit for Lifelong Health and AgeingDepartment of Population Science & Experimental MedicineUCL Institute of Cardiovascular ScienceUniversity College LondonLondonUnited Kingdom
| | - Guy Lloyd
- Department of Cardiovascular ImagingBarts Heart CentreBarts Health NHS TrustLondonUnited Kingdom
| | - Jamil Mayet
- NIHR Imperial Biomedical Research CentreImperial College London and Imperial College Healthcare NHS TrustHammersmith HospitalLondonUnited Kingdom
| | - Nish Chaturvedi
- MRC Unit for Lifelong Health and AgeingDepartment of Population Science & Experimental MedicineUCL Institute of Cardiovascular ScienceUniversity College LondonLondonUnited Kingdom
| | - Alun D. Hughes
- MRC Unit for Lifelong Health and AgeingDepartment of Population Science & Experimental MedicineUCL Institute of Cardiovascular ScienceUniversity College LondonLondonUnited Kingdom
| |
Collapse
|
4
|
Raslan M, Elkhashab KA, Mousa MG, Alghamdi YA, Ghareb HS. A Comparison Between Two-Dimensional and Three-Dimensional Regional and Global Longitudinal Strain Echocardiography to Evaluate Complex Coronary Lesions in Patients With Non-ST-Segment Elevation Acute Coronary Syndrome. Cureus 2022; 14:e24025. [PMID: 35444922 PMCID: PMC9010239 DOI: 10.7759/cureus.24025] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2022] [Indexed: 11/05/2022] Open
Abstract
Introduction A preliminary assessment of patients who suffer from severe and complex coronary artery lesions, such as three-vessel disease and/or a left main (LM) artery lesion, plays a critical contribution in determining prognosis and treatment plans for non-ST-segment elevation acute coronary syndrome (NSTE-ACS). Therefore, a pre-angiography (i.e., before angiography) predictor was required to cost-effectively evaluate severe and complex coronary lesions to efficiently direct our subsequent dealing. Aim This study aimed to compare two-dimensional (2D) and three-dimensional (3D) global longitudinal strain (GLS) at the regional level to assess extremely complicated coronary lesions using the SYNTAX score as a standard of reference in 100 patients with NSTE-ACS. Materials and methods This research included 100 patients with non-ST-segment elevation acute coronary syndrome who presented at the Cardiology Department at Fayoum University from December 2019 to July 2020. All patients underwent a complete history and physical examination, hemoglobin A1c (HbA1c), lipid profile, creatinine assessment, 12-lead electrocardiogram (ECG), and transthoracic echocardiography (TTE) to detect global and regional longitudinal strain by 2D and 3D speckle-tracking echocardiography (STE). Coronary angiography was done on all patients within 24 hours of admission after acquiring echo images. Then, the results of 2D and 3D regional and global longitudinal strain (GLS) to predict the severity and coronary lesion complexity in terms of the SYNTAX score were compared. Results This study revealed that 2D GLS was −12.10 ± 3.51, which is significantly higher than 3D GLS of −11.64 ± 4.05 (p < 0. 001). The left anterior descending coronary artery (LAD) and left circumflex artery (LCX) territories revealed a significantly higher value using 2D regional longitudinal strain (−11.13 ± 4.47 and −12.54 ± 4.11, respectively) than using 3D regional longitudinal strain (−10.84 ± 5.18 and −12.05 ± 4.29, respectively) (p= 0.017 and p < 0.001, respectively). There were significantly lower 2D GLS, 3D GLS, global circumferential strain (GCS), area strain, and global radial strain (GRS) in the intermediate and high score group than in the low score group of patients (p < 0.001 for all). Conclusion 2D and 3D strain echocardiography including GLS, GCS, GRS, and area strain are a noninvasive and rapid tool with clinical utility for evaluating coronary lesions in patients with NSTE-ACS. They can be routinely used to diagnose and stratify high-risk patients with NSTE-ACS, thereby potentially resulting in improved patient assessment. GLS as measured by 2D and 3D STE at minimal effort is a significant risk factor for patients with complex NSTE-ACS. In NSTE-ACS cases, the GLS absolute value is significantly associated with the degree of complexity of coronary artery lesions.
Collapse
|
5
|
Skaarup KG, Lassen MCH, Johansen ND, Olsen FJ, Lind JN, Jørgensen PG, Jensen G, Schnohr P, Prescott E, Søgaard P, Møgelvang R, Biering-Sørensen T. Age- and sex-based normal values of layer-specific longitudinal and circumferential strain by speckle tracking echocardiography: the Copenhagen City Heart Study. Eur Heart J Cardiovasc Imaging 2021; 23:629-640. [PMID: 33624014 DOI: 10.1093/ehjci/jeab032] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 02/09/2021] [Indexed: 11/12/2022] Open
Abstract
AIMS Technical advancements in 2D-speckle tracking echocardiography (2DSTE) have allowed for quantification of layer-specific global longitudinal strain (GLS) and circumferential strain (GCS) of the left ventricle (LV). The aim of this study was to establish age- and sex-based reference ranges of peak systolic layer-specific GLS and GCS and to assess normal values of regional strain. METHODS AND RESULTS We performed 2DSTE analysis of 1997 members of the general population from the fifth round of the Copenhagen City Heart Study, who were free of cardiovascular disease and risk factors. The mean age was 46 ± 16 years (range 21-97) and 62% were female. Mean values for peak systolic whole wall GLS (GLSWW.Sys), endomycardial (GLSEndo.Sys), and epimyocardial (GLSEpi.Sys) were 19.9 ± 2.1% (prediction interval [PI]: 15.8-24.0%), 23.5 ± 2.5% (PI: 18.6-28.4%), and 17.3 ± 1.9% (PI: 13.6-21.1%), respectively. Mean peak systolic whole wall GCS (GCSWW.Sys), was 21.6 ± 3.7% (PI: 14.3-28.9%), endomyocardial (GCSEndo.Sys) was 31.9 ± 4.7% (PI: 22.7-41.1%), and epimyocardial (GCSEpi.Sys) was 14.3 ± 3.8% (PI: 6.8-21.8%). A significant discrepancy in normal strain values between males and females was observed. Men had lower mean values and lower reference limits for all strain parameters. Furthermore, GLS and GCS changed differently with age in males and females. Finally, regional LS decreased from the apical to the basal LV region in both sexes, and regional CS varied significantly by LV segment. CONCLUSION In this study, we reported age- and sex-based reference ranges of layer-specific GLS and GCS. These reference ranges varied significantly with sex and age.
Collapse
Affiliation(s)
- Kristoffer Grundtvig Skaarup
- Department of Cardiology, Herlev and Gentofte University Hospital, Kildegårdsvej 28, DK-2900, Post 835, Copenhagen, Denmark
| | - Mats Christian Højbjerg Lassen
- Department of Cardiology, Herlev and Gentofte University Hospital, Kildegårdsvej 28, DK-2900, Post 835, Copenhagen, Denmark
| | - Niklas Dyrby Johansen
- Department of Cardiology, Herlev and Gentofte University Hospital, Kildegårdsvej 28, DK-2900, Post 835, Copenhagen, Denmark
| | - Flemming Javier Olsen
- Department of Cardiology, Herlev and Gentofte University Hospital, Kildegårdsvej 28, DK-2900, Post 835, Copenhagen, Denmark
| | - Jannie Nørgaard Lind
- Department of Cardiology, Herlev and Gentofte University Hospital, Kildegårdsvej 28, DK-2900, Post 835, Copenhagen, Denmark
| | - Peter Godsk Jørgensen
- Department of Cardiology, Herlev and Gentofte University Hospital, Kildegårdsvej 28, DK-2900, Post 835, Copenhagen, Denmark.,The Copenhagen City Heart Study, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark
| | - Gorm Jensen
- The Copenhagen City Heart Study, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark
| | - Peter Schnohr
- The Copenhagen City Heart Study, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark
| | - Eva Prescott
- The Copenhagen City Heart Study, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark.,Department of Cardiology, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark
| | - Peter Søgaard
- The Copenhagen City Heart Study, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark.,Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark.,Institute of Clinical Medicine, Faculty of Medicine, University of Aalborg, Aalborg, Denmark
| | - Rasmus Møgelvang
- The Copenhagen City Heart Study, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark.,Department of Cardiology, Rigshospitalet, Copenhagen, Denmark.,Cardiovascular Research Unit, University of Southern Denmark, Odense, Denmark.,Institute of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Tor Biering-Sørensen
- Department of Cardiology, Herlev and Gentofte University Hospital, Kildegårdsvej 28, DK-2900, Post 835, Copenhagen, Denmark.,The Copenhagen City Heart Study, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark.,Institute of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
6
|
Abdelrazek G, Yassin A, Elkhashab K. Correlation between global longitudinal strain and SYNTAX score in coronary artery disease evaluation. Egypt Heart J 2020; 72:22. [PMID: 32415353 PMCID: PMC7229084 DOI: 10.1186/s43044-020-00064-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 05/03/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Speckle tracking echocardiography may allow the evaluation of myocardial systolic and diastolic dynamics across different physiologic and pathologic conditions beyond traditional echocardiographic techniques. The use of STE longitudinal strain in identification and risk stratification of CAD has good reproducibility and accuracy. The study aims to detect the relationship between SYNTAX score and global longitudinal peak systolic strain (GLPSS) in patients undergoing coronary angiography, with no history of myocardial infarction. RESULTS The study included 70 symptomatic patients suspected to have chronic coronary syndrome aging 20-80 years (excluding those with significant structural heart disease). All patients underwent clinical evaluation, surface ECG, laboratory assessment, transthoracic echocardiographic (TTE), color TDI tracings, two-dimensional speckle tracking, and conventional coronary angiography with SYNTAX score calculation. Patients were divided into 3 groups based on the results of the coronary angiogram: normal CAD on angiogram (n = 10, control group), low SS (n = 25, SS < 22), and high SS (n = 35, SS ≥ 22). The mean age was 55 ± 9.6 years; 54% were males; two third of patients were hypertensive; 52% were diabetic; high percentage of high syntax score were noticed among males, diabetic patients, and smokers; and also low mean of GLS was noticed among diabetic patients and smokers. There was a statistically significant positive correlation between syntax score and each of LVEDD and LVESD and, on the other hand, statistically significant negative correlation between syntax score and each of E/A, GLS, AP2LS, AP3LS, and AP4LS was noticed. Peak GLS cutoff value of 17.8 and 16.5 showed 84% and 93% sensitivity and 70% and 91% specificity to detect high and low syntax score, respectively. CONCLUSION 2D longitudinal strain analysis has incremental diagnostic value over visual assessment during echocardiography in predicting significant coronary artery disease; GLS may offer a potential sensitive tool to detect significant CAD.
Collapse
|
7
|
Hjertaas JJ, Matre K. A left ventricular phantom for 3D echocardiographic twist measurements. BIOMED ENG-BIOMED TE 2020; 65:209-218. [DOI: 10.1515/bmt-2019-0096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Accepted: 07/08/2019] [Indexed: 11/15/2022]
Abstract
AbstractTraditional two-dimensional (2D) ultrasound speckle tracking echocardiography (STE) studies have shown a wide range of twist values, also for normal hearts, which is due to the limitations of short-axis 2D ultrasound. The same limitations do not apply to three-dimensional (3D) ultrasound, and several studies have shown 3D ultrasound to be superior to 2D ultrasound, which is unreliable for measuring twist. The aim of this study was to develop a left ventricular twisting phantom and to evaluate the accuracy of 3D STE twist measurements using different acquisition methods and volume rates (VR). This phantom was not intended to simulate a heart, but to function as a medium for ultrasound deformation measurement. The phantom was made of polyvinyl alcohol (PVA) and casted using 3D printed molds. Twist was obtained by making the phantom consist of two PVA layers with different elastic properties in a spiral pattern. This gave increased apical rotation with increased stroke volume in a mock circulation. To test the accuracy of 3D STE twist, both single-beat, as well as two, four and six multi-beat acquisitions, were recorded and compared against twist from implanted sonomicrometry crystals. A custom-made software was developed to calculate twist from sonomicrometry. The phantom gave sonomicrometer twist values from 2.0° to 13.8° depending on the stroke volume. STE software tracked the phantom wall well at several combinations of temporal and spatial resolution. Agreement between the two twist methods was best for multi-beat acquisitions in the range of 14.4–30.4 volumes per second (VPS), while poorer for single-beat and higher multi-beat VRs. Smallest offset was obtained at six-beat multi-beat at 17.1 VPS and 30.4 VPS. The phantom proved to be a useful tool for simulating cardiac twist and gave different twist at different stroke volumes. Best agreement with the sonomicrometer reference method was obtained at good spatial resolution (high beam density) and a relatively low VR. 3D STE twist values showed better agreement with sonomicrometry for most multi-beat recordings compared with single-beat recordings.
Collapse
Affiliation(s)
- Johannes Just Hjertaas
- Department of Clinical Science, University of Bergen, Haukeland University Hospital, 5021 Bergen, Norway
| | - Knut Matre
- Department of Clinical Science, University of Bergen, Haukeland University Hospital, 5021 Bergen, Norway
| |
Collapse
|
8
|
Patey O, Carvalho JS, Thilaganathan B. Left ventricular torsional mechanics in term fetuses and neonates. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 55:233-241. [PMID: 30887619 DOI: 10.1002/uog.20261] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/01/2019] [Revised: 03/07/2019] [Accepted: 03/12/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVE Left ventricular (LV) torsion is an important aspect of cardiac mechanics and is fundamental to normal ventricular function. The myocardial mechanics of the fetal heart and the changes that occur during the transition to the neonatal period have not been explored previously. The aim of this study was to evaluate perinatal changes in LV torsion and its relationship with myocardial function. METHODS This was a prospective study of 36 women with an uncomplicated term pregnancy. Fetal and neonatal conventional, spectral tissue Doppler and two-dimensional (2D) speckle tracking echocardiography were performed a few days before and within hours after delivery to measure cardiac indices including LV rotational parameters derived from short-axis views at the base and apex of the heart. Linear regression analysis was used to examine the relationship between LV rotational parameters and cardiac geometric and functional indices in term fetuses and neonates. Perinatal changes in LV rotational parameters were assessed. RESULTS There were three patterns of LV twist in term fetuses: those with reversed-apex-type LV twist had the lowest median values of LV torsion (0.1°/cm), with higher values (1.6°/cm) in those with infant-type LV twist and the highest values (4.4°/cm) in those with adult-type LV twist. LV torsion was associated significantly with cardiac geometric and functional indices. Perinatal evaluation revealed a significant increase in LV torsion following delivery in fetuses exhibiting reversed-apex-type LV twist (increase of 2.8°/cm, P = 0.009) and a significant decrease in those with adult-type LV twist (decrease of 3.2°/cm, P = 0.008). CONCLUSIONS This study demonstrates the feasibility of 2D speckle tracking imaging for accurate assessment of rotational cardiac parameters in term fetuses. There are unique perinatal patterns of LV twist that demonstrate different values of LV torsion, which was found to correlate with indices of ventricular geometry and myocardial function. Differences in patterns of LV twist may therefore reflect differences in compensatory myocardial adaptation to the physiological environment/loading conditions in late gestation in fetuses and postnatal cardiac adjustment to the acute loading changes that occur at delivery. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- O Patey
- Vascular Biology Research Centre, Molecular & Clinical Sciences Research Institute, St George's University of London, London, UK
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, University of London, London, UK
- Brompton Centre for Fetal Cardiology, Royal Brompton and Harefield Hospitals NHS Foundation Trust, London, UK
| | - J S Carvalho
- Vascular Biology Research Centre, Molecular & Clinical Sciences Research Institute, St George's University of London, London, UK
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, University of London, London, UK
- Brompton Centre for Fetal Cardiology, Royal Brompton and Harefield Hospitals NHS Foundation Trust, London, UK
| | - B Thilaganathan
- Vascular Biology Research Centre, Molecular & Clinical Sciences Research Institute, St George's University of London, London, UK
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, University of London, London, UK
| |
Collapse
|
9
|
Intervendor Discordance of Fetal and Neonatal Myocardial Tissue Doppler and Speckle-Tracking Measurements. J Am Soc Echocardiogr 2019; 32:1339-1349.e23. [PMID: 31351791 DOI: 10.1016/j.echo.2019.05.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 05/23/2019] [Accepted: 05/24/2019] [Indexed: 12/15/2022]
Abstract
BACKGROUND Fetal and neonatal studies report a wide range of cardiac parameters derived by pulsed-wave Doppler tissue imaging (DTI) and two-dimensional speckle-tracking echocardiographic (STE) imaging. The use of different ultrasound systems and their vendor-specific software compromises the ability to compare echocardiographic findings among various studies. The aim of this study was to evaluate intervendor reproducibility as well as intra- and interobserver repeatability of DTI and STE measurements in normal-term fetuses and neonates. METHODS A prospective study was conducted of term fetuses (n = 196) from uncomplicated pregnancies assessed days before the onset of labor and a few hours after birth. Fetal and neonatal DTI and STE parameters were obtained and analyzed using vendor-specific software on three ultrasound systems: Toshiba Aplio MX versus GE Vivid E9 and GE Vivid E9 versus Philips EPIQ. A reproducibility study in fetuses and neonates (n = 118) was performed by systematic scanning with head-to-head comparison. RESULTS DTI reproducibility showed moderate to good correlation, with good agreement for fetuses and neonates on Toshiba versus GE (intraclass correlation coefficient [ICC] = 0.4-0.8). Correlation of DTI measurements on GE versus Philips was poor to moderate for fetuses (ICC = 0.1-0.6) and moderate to good for neonates (ICC = 0.5-0.8), with wider limits of agreement. Fetal and neonatal STE parameters revealed very poor correlation (ICC = 0.1-0.3) and agreement among ultrasound vendors. Intra- and interobserver repeatability demonstrated good to excellent correlation of all fetal and neonatal DTI and STE measurements, with good agreement irrespective of the ultrasound platform used. CONCLUSIONS These findings demonstrate reliable assessment of fetal and neonatal DTI and STE measurements when performed on the same ultrasound platform, whereas ultrasound machines and software from different vendors give significantly divergent estimates of DTI and STE parameters in fetuses and neonates. These intervendor discrepancies have significant clinical and research implications and should be considered when interpreting and comparing study findings, establishing reference standards, or performing systematic reviews.
Collapse
|
10
|
Kowallick JT, Morton G, Lamata P, Jogiya R, Kutty S, Lotz J, Hasenfuß G, Nagel E, Chiribiri A, Schuster A. Inter-study reproducibility of left ventricular torsion and torsion rate quantification using MR myocardial feature tracking. J Magn Reson Imaging 2015; 43:128-37. [PMID: 26114731 DOI: 10.1002/jmri.24979] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Accepted: 06/02/2015] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND To determine the inter-study reproducibility of MR feature tracking (MR-FT) derived left ventricular (LV) torsion and torsion rates for a combined assessment of systolic and diastolic myocardial function. METHODS Steady-state free precession (SSFP) cine LV short-axis stacks were acquired at 9:00 (Exam A), 9:30 (Exam B), and 14:00 (Exam C) in 16 healthy volunteers at 3 Tesla. SSFP images were analyzed offline using MR-FT to assess rotational displacement in apical and basal slices. Global peak torsion, peak systolic and peak diastolic torsion rates were calculated using different definitions ("twist", "normalized twist" and "circumferential-longitudinal (CL) shear angle"). Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to address possible diurnal variation. RESULTS The different methods showed good inter-study reproducibility for global peak torsion (intraclass correlation coefficient [ICC]: 0.90-0.92; coefficient of variation [CoV]: 19.0-20.3%) and global peak systolic torsion rate (ICC: 0.82-0.84; CoV: 25.9-29.0%). Conversely, global peak diastolic torsion rate showed little inter-study reproducibility (ICC: 0.34-0.47; CoV: 40.8-45.5%). Global peak torsion as determined by the CL shear angle showed the best inter-study reproducibility (ICC: 0.90;CoV: 19.0%). MR-FT results were not measurably affected by diurnal variation between morning and afternoon scans (CL shear angle: 4.8 ± 1.4°, 4.8 ± 1.5°, and 4.1 ± 1.6° for Exam A, B, and C, respectively; P = 0.21). CONCLUSION MR-FT based derivation of myocardial peak torsion and peak systolic torsion rate has high inter-study reproducibility as opposed to peak diastolic torsion rate. The CL shear angle was the most reproducible parameter independently of cardiac anatomy and may develop into a robust tool to quantify cardiac rotational mechanics in longitudinal MR-FT patient studies.
Collapse
Affiliation(s)
- Johannes T Kowallick
- Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, St Thomas' Hospital, King's College London, London, United Kingdom.,Institute for Diagnostic and Interventional Radiology, Georg-August-University Göttingen, Göttingen, Germany.,DZHK (German Centre for Cardiovascular Research), partner site Göttingen, Germany
| | - Geraint Morton
- Portsmouth Hospitals NHS Trust, Portsmouth, United Kingdom
| | - Pablo Lamata
- Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, St Thomas' Hospital, King's College London, London, United Kingdom.,Department of Computer Science, University of Oxford, Oxford, United Kingdom
| | - Roy Jogiya
- Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Shelby Kutty
- Children's Hospital and Medical Center, University of Nebraska College of Medicine, Omaha, Nebraska, USA
| | - Joachim Lotz
- Institute for Diagnostic and Interventional Radiology, Georg-August-University Göttingen, Göttingen, Germany.,DZHK (German Centre for Cardiovascular Research), partner site Göttingen, Germany
| | - Gerd Hasenfuß
- DZHK (German Centre for Cardiovascular Research), partner site Göttingen, Germany.,Department of Cardiology and Pneumology, Georg-August-University Göttingen, Göttingen, Germany
| | - Eike Nagel
- Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Amedeo Chiribiri
- Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Andreas Schuster
- Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, St Thomas' Hospital, King's College London, London, United Kingdom.,DZHK (German Centre for Cardiovascular Research), partner site Göttingen, Germany.,Department of Cardiology and Pneumology, Georg-August-University Göttingen, Göttingen, Germany
| |
Collapse
|
11
|
Chang SA. Ventricular torsion: research tool or novel clinical indicator? J Cardiovasc Ultrasound 2014; 21:163-4. [PMID: 24459562 PMCID: PMC3894366 DOI: 10.4250/jcu.2013.21.4.163] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2013] [Revised: 12/04/2013] [Accepted: 12/05/2013] [Indexed: 11/22/2022] Open
Affiliation(s)
- Sung-A Chang
- Division of Cardiology, Department of Medicine, Cardiovascular Imaging Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|