1
|
Zhang Z, Jiang H, Zhou H, Zhou F. Comparative Efficacy Between Trifocal and Bifocal Intraocular Lens Among Patients Undergoing Cataract Surgery: A Systematic Review and Meta-Analysis. Front Med (Lausanne) 2021; 8:647268. [PMID: 34660614 PMCID: PMC8514957 DOI: 10.3389/fmed.2021.647268] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Accepted: 09/06/2021] [Indexed: 11/24/2022] Open
Abstract
The comparative efficacy of trifocal and bifocal intraocular lenses (IOLs) remained uncertain among patients undergoing cataract surgery. A systematic review and meta-analysis was performed to answer this question. PubMed, Cochrane Library and Embase were searched to capture relevant randomized controlled trials (RCTs). Visual acuity (VA) and patient's satisfaction were regarded as primary outcomes. Secondary outcomes included residual sphere, spherical equivalence, residual cylinder, posterior capsular opacification (PCO), spectacle independence, and other complications. Statistical analysis was done using RevMan 5.2.0. A total of 9 studies (11 RCTs) with 297 participants (558 eyes) were included. Meta-analysis showed significant differences between trifocal and bifocal IOLs in the uncorrected near VA (mean difference [MD], −0.008; 95% confidence interval [Cl], −0.015 to −0.001; P = 0.028) and uncorrected intermediate VA (MD, −0.06; 95% CI, −0.10 to −0.02; P < 0.01). Trifocal IOLs were associated with decreased PCO incidence when compared to bifocal IOLs (relative risk [RR], 0.54; 95% CI, 0.31 to 0.95; P = 0.03). Trifocal IOLs may be superior to bifocal IOLs because of its improved intermediate VA and reduced incidence of PCO.
Collapse
Affiliation(s)
- Ziran Zhang
- Department of Clinical Medicine, First Clinical Medical College, Nanjing Medical University, Nanjing, China
| | - Haiyang Jiang
- Department of Geriatrics, Huai'an Medical Area, Affiliated General Hospital of Eastern Theater Command, Huai'an, China
| | - Hongwei Zhou
- Department of Ophthalmology, The Affiliated Lianshui County People's Hospital of Kangda College of Nanjing Medical Universty, Huai'an, China
| | - Fang Zhou
- Beijing Key Laboratory of Megaregions Sustainable Development Modeling, Capital University of Economics and Business, Beijing, China.,Department of Public Affairs, College of Urban Economics and Public Administration, Capital University of Economics and Business, Beijing, China
| |
Collapse
|
2
|
Yang JJ, Qin YZ, Qin L, Li JM. Comparison of the clinical efficacy of AcrySof ® IQ and TECNIS ® toric intraocular lenses: A real-world study. Exp Ther Med 2020; 20:25. [PMID: 32934690 PMCID: PMC7471847 DOI: 10.3892/etm.2020.9153] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Accepted: 05/13/2020] [Indexed: 11/23/2022] Open
Abstract
Corneal astigmatism significantly compromises uncorrected visual acuity (UCVA) after phacoemulsification with implantation of traditional spherical or non-spherical monofocal intraocular lens (IOL). Toric IOL provides an effective way to gain favorable postoperative UCVA for the patients with cataracts with corneal astigmatism. There are numerous types of toric IOLs; however AcrySof® IQ toric IOL (Alcon Laboratories, Inc.) and TECNIS® toric IOL (Johnson & Johnson Vision; Johnson & Johnson) are most frequently used in our clinical practice. The purpose of the current study was to compare the clinical efficacy of AcrySof IQ with TECNIS toric IOL implantation, and to provide a clinical basis on selecting an appropriate toric IOL before cataract surgery for patients with corneal astigmatism. A total of 30 patients with cataract (44 eyes) with corneal astigmatism [0.82-7.27 diopters (D)], who have undergone phacoemulsification with toric IOL implantation between October 2012 and December 2017, were included in the current retrospective cohort study. Patients were divided into two groups: One group (26 eyes) received the AcrySof IQ toric IOL (AcrySof group) and the other group (18 eyes) received the TECNIS toric IOL (Tecnis group). The indexes of curative effect, such as uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively), refractive outcomes, contrast sensitivity (CS), IOL rotation, and satisfaction, were evaluated. Both toric IOLs significantly improved UDVA and CDVA. Postoperative mean residual astigmatism was similar in the AcrySof group and in the Tecnis group (0.75±0.50 and 0.78±0.90 D; P=0.896). There was no statistically significant between postoperative CS in the AcrySof and Tecnis groups. Rotations of >10˚ were considered to be significant and were identified in three eyes. The mean IOL rotation showed no statistically significant difference (AcrySof group, 0.24±5.54˚; Tecnis group, -0.19±6.28˚; P=0.416). The mean patient satisfaction score was 8.46±1.21 in the AcrySof group and 8.78±1.44 in the Tecnis group (P=0.260). The results of the current study indicated that patients with cataracts with corneal astigmatism undergoing phacoemulsification with AcrySof IQ and TECNIS toric IOL implantation achieved similar clinical efficacy in term of visual outcomes, refraction correction, CS, rotational stability and satisfaction.
Collapse
Affiliation(s)
- Juan-Juan Yang
- Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Ya-Zhou Qin
- Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Li Qin
- Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Jing-Ming Li
- Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| |
Collapse
|
3
|
Du W, Lou W, Wu Q. Personalized aspheric intraocular lens implantation based on corneal spherical aberration: a review. Int J Ophthalmol 2019; 12:1788-1792. [PMID: 31741870 DOI: 10.18240/ijo.2019.11.19] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Accepted: 08/28/2019] [Indexed: 01/19/2023] Open
Abstract
With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses (IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attributed to negative or zero spherical aberrations with unique optical designs, which counteract some of the positive spherical aberrations of the cornea. These alterations reduce the total spherical aberration of human eyes and improve the visual acuity in patients with cataract postoperatively. At present, various types of aspheric IOLs are used worldwide. Although the implantation of aspheric IOL is beneficial to the patients who need correction of spherical aberrations, much controversy is still associated with ocular residual spherical aberrations that facilitate the best visual quality for patients postoperatively. In order to provide reference for future clinical work and scientific research, this report reviews the relationship between the ocular residual spherical aberration of human eyes and visual quality.
Collapse
Affiliation(s)
- Wei Du
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Wei Lou
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Qiang Wu
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| |
Collapse
|
4
|
Golozar A, Chen Y, Lindsley K, Rouse B, Musch DC, Lum F, Hawkins BS, Li T. Identification and Description of Reliable Evidence for 2016 American Academy of Ophthalmology Preferred Practice Pattern Guidelines for Cataract in the Adult Eye. JAMA Ophthalmol 2019; 136:514-523. [PMID: 29800249 DOI: 10.1001/jamaophthalmol.2018.0786] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Importance Trustworthy clinical practice guidelines require reliable systematic reviews of the evidence to support recommendations. Since 2016, the American Academy of Ophthalmology (AAO) has partnered with Cochrane Eyes and Vision US Satellite to update their guidelines, the Preferred Practice Patterns (PPP). Objective To describe experiences and findings related to identifying reliable systematic reviews that support topics likely to be addressed in the 2016 update of the 2011 AAO PPP guidelines on cataract in the adult eye. Design, Setting, and Participants Cross-sectional study. Systematic reviews on the management of cataract were searched for in an established database. Each relevant systematic review was mapped to 1 or more of the 24 management categories listed under the Management section of the table of contents of the 2011 AAO PPP guidelines. Data were extracted to determine the reliability of each systematic review using prespecified criteria, and the reliable systematic reviews were examined to find whether they were referenced in the 2016 AAO PPP guidelines. For comparison, we assessed whether the reliable systematic reviews published before February 2010 the last search date of the 2011 AAO PPP guidelines were referenced in the 2011 AAO PPP guidelines. Cochrane Eyes and Vision US Satellite did not provide systematic reviews to the AAO during the development of the 2011 AAO PPP guidelines. Main Outcomes and Measures Systematic review reliability was defined by reporting eligibility criteria, performing a comprehensive literature search, assessing methodologic quality of included studies, using appropriate methods for meta-analysis, and basing conclusions on review findings. Results From 99 systematic reviews on management of cataract, 46 (46%) were classified as reliable. No evidence that a comprehensive search had been conducted was the most common reason a review was classified as unreliable. All 46 reliable systematic reviews were cited in the 2016 AAO PPP guidelines, and 8 of 15 available reliable reviews (53%) were cited in the 2011 PPP guidelines. Conclusions and Relevance The partnership between Cochrane Eyes and Vision US Satellite and the AAO provides the AAO access to an evidence base of relevant and reliable systematic reviews, thereby supporting robust and efficient clinical practice guidelines development to improve the quality of eye care.
Collapse
Affiliation(s)
- Asieh Golozar
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | - Yujiang Chen
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | - Kristina Lindsley
- Department of Epidemiology, Center for Clinical Trials and Evidence Synthesis, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | - Benjamin Rouse
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | - David C Musch
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor.,Department of Epidemiology, University of Michigan, Ann Arbor
| | - Flora Lum
- American Academy of Ophthalmology, San Francisco, California
| | - Barbara S Hawkins
- Department of Epidemiology, Center for Clinical Trials and Evidence Synthesis, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland.,Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland
| | - Tianjing Li
- Department of Epidemiology, Center for Clinical Trials and Evidence Synthesis, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| |
Collapse
|
5
|
Yang JJ, Liu QP, Li JM, Qin L. Comparison of visual outcomes with implantation of trifocal versus bifocal intraocular lens after phacoemulsification: a Meta-analysis. Int J Ophthalmol 2018; 11:484-492. [PMID: 29600184 DOI: 10.18240/ijo.2018.03.20] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2017] [Accepted: 01/08/2018] [Indexed: 11/23/2022] Open
Abstract
AIM To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS Eligible literatures were systematically searched through EMBASE and PubMed databases. The inclusion criteria were prospective comparative clinical trials on cataract surgery comparing trifocal IOL with bifocal IOL implantation that assessed visual acuity, contrast sensitivity and subjective vision quality. The effects were computed as standardized mean differences and pooled using fixed-effect or random-effect models. RESULTS Four prospective randomized controlled trials (RCTs) and five cohorts provided data were included by a systematic review, comprising 265 eyes implanted with trifocal IOLs and 264 eyes implanted with bifocal IOLs. Monocular distance visual acuity (VA) showed a statistically significant but small difference that favored trifocal IOLs (MD=-0.06; 95%CI, -0.10 to -0.02; Z=2.90, P=0.004 for uncorrected distance VA, and MD= -0.02; 95%CI, -0.03 to -0.00; Z=2.02, P=0.04 for corrected distance VA), but the data did not suggest that the effect of trifocal IOL implantation would clinically outperform bifocal IOL implantation. There was no significant difference in monocular near VA (MD=-0.01; 95%CI, -0.07 to 0.04; Z=0.42, P=0.68 for distance-corrected near VA, and MD=-0.01; 95%CI, -0.06 to 0.03; Z=0.55, P=0.58 for corrected near VA) or refraction between two groups. Contrast sensitivity and subjective visual quality had no conclusive results. CONCLUSION All results indicate that trifocal IOL and bifocal IOL had similar levels of monocular distance and near VA.
Collapse
Affiliation(s)
- Juan-Juan Yang
- Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Qiu-Ping Liu
- Department of Ophthalmology, Affiliated Eye Hospital of Nanchang University, Nanchang 330006, Jiangxi Province, China
| | - Jing-Ming Li
- Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Li Qin
- Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| |
Collapse
|
6
|
Clinical study inpatient-reported outcomes after binocular implantation of aspheric intraocular lens of different negative spherical aberrations. ASIAN PAC J TROP MED 2017; 10:710-713. [DOI: 10.1016/j.apjtm.2017.07.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 06/30/2017] [Accepted: 07/05/2017] [Indexed: 11/19/2022] Open
|
7
|
Chen Y, Wang X, Zhou CD, Wu Q. Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System. Int J Ophthalmol 2017; 10:914-918. [PMID: 28730082 DOI: 10.18240/ijo.2017.06.13] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Accepted: 01/20/2017] [Indexed: 12/12/2022] Open
Abstract
AIM To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS There were no significant differences in visual acuity (P>0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (r=-0.634, P=0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.5±0.8 before and 1d, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P<0.01) between the two groups. CONCLUSION Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.
Collapse
Affiliation(s)
- Yan Chen
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Xue Wang
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Chuan-Di Zhou
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated First People's Hospital, Shanghai 200080, China
| | - Qiang Wu
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| |
Collapse
|
8
|
Hiraoka T, Miyata K, Hayashidera T, Iida M, Takada K, Minami K, Oshika T. Influence of intraocular lens subsurface nanoglistenings on functional visual acuity. PLoS One 2017; 12:e0173574. [PMID: 28328997 PMCID: PMC5362055 DOI: 10.1371/journal.pone.0173574] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 02/23/2017] [Indexed: 11/22/2022] Open
Abstract
To investigate the influence of intraocular lens subsurface nanoglistenings (SSNGs) on functional visual acuity (FVA), thirty-nine eyes of 29 patients were examined in this study. The SSNG group comprised 19 eyes of 14 patients (75.7± 5.4 years, mean ± standard deviation), and the control group comprised 20 eyes of 15 patients (73.6 ± 6.5 years). The SSNGs were diagnosed on the basis of the typical whitish IOL appearance upon slit-lamp examination and results of densitometry regarding surface light scattering using Scheimpflug images. The FVA measurement system (AS-28; Kowa, Aichi, Japan) was used to examine changes in continuous visual acuity (VA) over time, and visual function parameters such as FVA, visual maintenance ratio (VMR), maximum VA, minimum VA, standard deviation of VA, and number of blinks were assessed. The results were compared between the SSNG and control groups, and correlations of FVA parameters with the intensity of surface light scattering, time after surgery, and age were also evaluated. There were significant differences in VMR (P = 0.035) and standard deviation of VAs (P = 0.031) between the two groups, although no significant differences were found in baseline VA, FVA, maximum VA, minimum VA, and number of blinks. None of the FVA parameters showed any significant correlations with the intensity of surface light scattering, time after surgery, or age. There is a possibility that VA is unstable during a continuous gazing task in patients with SSNGs.
Collapse
Affiliation(s)
- Takahiro Hiraoka
- Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
- * E-mail:
| | - Kazunori Miyata
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki, Japan
| | - Takeshi Hayashidera
- Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| | - Masaharu Iida
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki, Japan
| | - Keita Takada
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki, Japan
| | - Keiichiro Minami
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki, Japan
| | - Tetsuro Oshika
- Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| |
Collapse
|
9
|
Influence of uncomplicated phacoemulsification on central macular thickness in diabetic patients: a meta-analysis. PLoS One 2015; 10:e0126343. [PMID: 25965404 PMCID: PMC4428827 DOI: 10.1371/journal.pone.0126343] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2015] [Accepted: 04/01/2015] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVE To evaluate the effect of uncomplicated phacoemulsification on central macular thickness (CMT) and best corrected visual acuity (BCVA) in both diabetic patients without diabetic retinopathy (DR) and diabetic patients with mild to moderate non-proliferative diabetic retinopathy (NPDR). METHODS Potential prospective observational studies were searched through PubMed and EMBASE. Standardized mean difference (SMD) and 95% confidence interval (CI) for changes in CMT and BCVA were evaluated at postoperative 1, 3 and 6 months. The pooled effect estimates were calculated in the use of a random-effects model. RESULTS A total of 10 studies involving 190 eyes of diabetic patients without diabetic retinopathy and 143 eyes of diabetic patients with NPDR were identified. CMT values demonstrated a statistically significant increase after uncomplicated phacoemulsification at 1 month (SMD, -0.814; 95%CI, -1.230 to -0.399), 3 months (SMD, -0.565; 95%CI, -0.927 to -0.202) and 6 months (SMD, -0.458; 95%CI, -0.739 to -0.177) in diabetic patients with NPDR. There was no statistical difference in CMT values at postoperative 1 month (SMD, -1.206; 95%CI, -2.433 to 0.021)and no statistically significant increase in CMT values at postoperative3 months (SMD, -0.535; 95%CI, -1.252 to 0.182) and 6 months (SMD, -1.181; 95%CI, -2.625 to 0.263) in diabetic patients without DR.BCVA was significantly increased at postoperative 1 month (SMD, 1.149; 95%CI, 0.251 to 2.047; and SMD,1.349; 95%CI, 0.264 to 2.434, respectively) and 6 months (SMD, 1.295; 95%CI, 0.494 to 2.096; and SMD, 2.146; 95%CI, 0.172 to 4.120, respectively) in both diabetic patients without DR and diabetic patients with NPDR. Sensitivity analysis showed that the results were relatively stable and reliable. CONCLUSION Uncomplicated phacoemulsification in diabetic patients with mild to moderate NPDR seemed to influence significantly the subclinical thickening of the macular zones at postoperative 1, 3 and 6 months compared with diabetic patients without DR. BCVA was significantly improved in both diabetic patients without DR and diabetic patients with mild to moderate NPDR.
Collapse
|
10
|
Uchida A, Inoue M, Bissen-Miyajima H, Hirakata A. Dynamic changes of optical aberrations during restoration of optical properties of hydrophobic acrylic intraocular lens ejected through cartridge. Br J Ophthalmol 2015; 99:1143-8. [PMID: 25868789 DOI: 10.1136/bjophthalmol-2014-306592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2015] [Accepted: 03/19/2015] [Indexed: 11/03/2022]
Abstract
AIM To evaluate the effect of temperature on the restoration of the optical properties of hydrophobic acrylic intraocular lenses (IOLs) after ejection through a cartridge into a temperature-controlled water chamber. METHODS Acrylic IOLs (SA60AT; iSert 251; W-60; X-70; and VA-70AD) were loaded into a cartridge with viscoelastic material and ejected into a water chamber at 24°C or 34°C. A wavefront analyser was used to measure the spherical and cylindrical powers, and the higher-order aberrations of the optics of the IOLs. The time to restore the cylindrical power to within 0.1 dioptres of the baseline power was determined. RESULTS Surface irregularities of the IOLs after ejection were detected in the dioptric power maps but not in the higher-order aberration maps. The cylindrical power and the astigmatic and coma aberrations recovered immediately at 34°C but were delayed at 24°C. The restoration time of all IOLs at 24°C was significantly longer than that at 34°C (p<0.05). CONCLUSIONS The dioptric power maps determined by the wavefront analyser can detect and follow the restoration of the optical properties of hydrophobic acrylic IOLs immediately after ejection. The restoration time was dependent on the temperature of the water chamber.
Collapse
Affiliation(s)
- Atsuro Uchida
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Makoto Inoue
- Kyorin Eye Center, Kyorin University School of Medicine, Tokyo, Japan Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan
| | | | - Akito Hirakata
- Kyorin Eye Center, Kyorin University School of Medicine, Tokyo, Japan
| |
Collapse
|