1
|
Lozano-Garcia M, Paredes FA, Jolley CJ, Jane R. Respiratory Sound Intensity as a Noninvasive Acoustic Biomarker in COPD. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40040117 DOI: 10.1109/embc53108.2024.10782895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
Chronic obstructive pulmonary disease (COPD) is a common respiratory disease and a leading cause of death worldwide. Due to the clinical heterogeneity of COPD and the low specificity of the spirometric tests currently used for diagnosing COPD, it is often under-diagnosed. The aim of this work is to explore the potential use of respiratory sound (RS) intensity as a noninvasive acoustic biomarker for the diagnosis and monitoring of COPD. Flow and RS signals were recorded in 15 healthy controls, 7 mild COPD patients, and 5 severe COPD patients, during the performance of a variable inspiratory flow protocol. RS intensity was estimated using fixed sample entropy. RS intensity showed a very strong correlation with respiratory flow in all participants. RS intensity and flow increased similarly during the variable inspiratory flow protocol. However, the increasing pattern of the two measures was different between healthy controls and COPD patients, with lower increases in COPD patients. RS intensity is therefore sensitive to altered respiratory mechanics in COPD and could therefore be used as a noninvasive acoustic biomarker for monitoring COPD patients.
Collapse
|
2
|
Gu X, Zhao X, Mao Z, Shi Y, Xu M, Cai M, Xie F. Effect of different anesthetic dose of pentobarbital on respiratory activity in rabbits. Comput Biol Med 2022; 145:105501. [DOI: 10.1016/j.compbiomed.2022.105501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 03/04/2022] [Accepted: 04/04/2022] [Indexed: 11/16/2022]
|
3
|
Borwankar S, Verma JP, Jain R, Nayyar A. Improvise approach for respiratory pathologies classification with multilayer convolutional neural networks. MULTIMEDIA TOOLS AND APPLICATIONS 2022; 81:39185-39205. [PMID: 35505670 PMCID: PMC9047583 DOI: 10.1007/s11042-022-12958-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 02/16/2022] [Accepted: 03/09/2022] [Indexed: 06/01/2023]
Abstract
Every respiratory-related checkup includes audio samples collected from the individual, collected through different tools (sonograph, stethoscope). This audio is analyzed to identify pathology, which requires time and effort. The research work proposed in this paper aims at easing the task with deep learning by the diagnosis of lung-related pathologies using Convolutional Neural Network (CNN) with the help of transformed features from the audio samples. International Conference on Biomedical and Health Informatics (ICBHI) corpus dataset was used for lung sound. Here a novel approach is proposed to pre-process the data and pass it through a newly proposed CNN architecture. The combination of pre-processing steps MFCC, Melspectrogram, and Chroma CENS with CNN improvise the performance of the proposed system, which helps to make an accurate diagnosis of lung sounds. The comparative analysis shows how the proposed approach performs better with previous state-of-the-art research approaches. It also shows that there is no need for a wheeze or a crackle to be present in the lung sound to carry out the classification of respiratory pathologies.
Collapse
Affiliation(s)
- Saumya Borwankar
- Institute of Technology, Nirma University, Ahmedabad, Gujarat India
| | | | - Rachna Jain
- IT department, Bhagwan Parshuram Institute of Technology, New Delhi, India
| | - Anand Nayyar
- Graduate School, Faculty of Information Technology, Duy Tan University, Da Nang, 550000 Vietnam
| |
Collapse
|
4
|
Blanco-Almazan D, Groenendaal W, Lozano-Garcia M, Estrada-Petrocelli L, Lijnen L, Smeets C, Ruttens D, Catthoor F, Jane R. Combining Bioimpedance and Myographic Signals for the Assessment of COPD During Loaded Breathing. IEEE Trans Biomed Eng 2020; 68:298-307. [PMID: 32746014 DOI: 10.1109/tbme.2020.2998009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Chronic Obstructive Pulmonary Disease (COPD) is one of the most common chronic conditions. The current assessment of COPD requires a maximal maneuver during a spirometry test to quantify airflow limitations of patients. Other less invasive measurements such as thoracic bioimpedance and myographic signals have been studied as an alternative to classical methods as they provide information about respiration. Particularly, strong correlations have been shown between thoracic bioimpedance and respiratory volume. The main objective of this study is to investigate bioimpedance and its combination with myographic parameters in COPD patients to assess the applicability in respiratory disease monitoring. We measured bioimpedance, surface electromyography and surface mechanomyography in forty-three COPD patients during an incremental inspiratory threshold loading protocol. We introduced two novel features that can be used to assess COPD condition derived from the variation of bioimpedance and the electrical and mechanical activity during each respiratory cycle. These features demonstrate significant differences between mild and severe patients, indicating a lower inspiratory contribution of the inspiratory muscles to global respiratory ventilation in the severest COPD patients. In conclusion, the combination of bioimpedance and myographic signals provides useful indices to noninvasively assess the breathing of COPD patients.
Collapse
|
5
|
Lozano-Garcia M, Davidson CM, Prieto-Ramon C, Moxham J, Rafferty GF, Jolley CJ, Jane R. Spatial Distribution of Normal Lung Sounds in Healthy Individuals under Varied Inspiratory Load and Flow Conditions. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2744-2747. [PMID: 33018574 DOI: 10.1109/embc44109.2020.9175992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Respiratory sounds yield pertinent information about respiratory function in both health and disease. Normal lung sound intensity is a characteristic that correlates well with airflow and it can therefore be used to quantify the airflow changes and limitations imposed by respiratory diseases. The dual aims of this study are firstly to establish whether previously reported asymmetries in normal lung sound intensity are affected by varying the inspiratory threshold load or the airflow of respiration, and secondly to investigate whether fixed sample entropy can be used as a valid measure of lung sound intensity. Respiratory sounds were acquired from twelve healthy individuals using four contact microphones on the posterior skin surface during an inspiratory threshold loading protocol and a varying airflow protocol. The spatial distribution of the normal lung sounds intensity was examined. During the protocols explored here the normal lung sound intensity in the left and right lungs in healthy populations was found to be similar, with asymmetries of less than 3 dB. This agrees with values reported in other studies. The fixed sample entropy of the respiratory sound signal was also calculated and compared with the gold standard root mean square representation of lung sound intensity showing good agreement.
Collapse
|
6
|
Lozano-Garcia M, Nuhic J, Moxham J, Rafferty GF, Jolley CJ, Jane R. Performance Evaluation of Fixed Sample Entropy for Lung Sound Intensity Estimation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2740-2743. [PMID: 33018573 DOI: 10.1109/embc44109.2020.9176215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Lung sound (LS) signals are often contaminated by impulsive artifacts that complicate the estimation of lung sound intensity (LSI) using conventional amplitude estimators. Fixed sample entropy (fSampEn) has proven to be robust to cardiac artifacts in myographic respiratory signals. Similarly, fSampEn is expected to be robust to artifacts in LS signals, thus providing accurate LSI estimates. However, the choice of fSampEn parameters depends on the application and fSampEn has not previously been applied to LS signals. This study aimed to perform an evaluation of the performance of the most relevant fSampEn parameters on LS signals, and to propose optimal fSampEn parameters for LSI estimation. Different combinations of fSampEn parameters were analyzed in LS signals recorded in a heterogeneous population of healthy subjects and chronic obstructive pulmonary disease patients during loaded breathing. The performance of fSampEn was assessed by means of its cross-covariance with flow signals, and optimal fSampEn parameters for LSI estimation were proposed.
Collapse
|
7
|
Blanco-Almazán D, Groenendaal W, Catthoor F, Jané R. Chest Movement and Respiratory Volume both Contribute to Thoracic Bioimpedance during Loaded Breathing. Sci Rep 2019; 9:20232. [PMID: 31882841 PMCID: PMC6934864 DOI: 10.1038/s41598-019-56588-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 12/10/2019] [Indexed: 11/22/2022] Open
Abstract
Bioimpedance has been widely studied as alternative to respiratory monitoring methods because of its linear relationship with respiratory volume during normal breathing. However, other body tissues and fluids contribute to the bioimpedance measurement. The objective of this study is to investigate the relevance of chest movement in thoracic bioimpedance contributions to evaluate the applicability of bioimpedance for respiratory monitoring. We measured airflow, bioimpedance at four electrode configurations and thoracic accelerometer data in 10 healthy subjects during inspiratory loading. This protocol permitted us to study the contributions during different levels of inspiratory muscle activity. We used chest movement and volume signals to characterize the bioimpedance signal using linear mixed-effect models and neural networks for each subject and level of muscle activity. The performance was evaluated using the Mean Average Percentage Errors for each respiratory cycle. The lowest errors corresponded to the combination of chest movement and volume for both linear models and neural networks. Particularly, neural networks presented lower errors (median below 4.29%). At high levels of muscle activity, the differences in model performance indicated an increased contribution of chest movement to the bioimpedance signal. Accordingly, chest movement contributed substantially to bioimpedance measurement and more notably at high muscle activity levels.
Collapse
Affiliation(s)
- Dolores Blanco-Almazán
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028, Barcelona, Spain.
- Universitat Politècnica de Catalunya · BarcelonaTech (UPC), Barcelona, Spain.
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain.
| | - Willemijn Groenendaal
- imec the Netherlands/Holst Centre, High tech campus 31, 5656AE, Eindhoven, The Netherlands
| | | | - Raimon Jané
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028, Barcelona, Spain
- Universitat Politècnica de Catalunya · BarcelonaTech (UPC), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
| |
Collapse
|
8
|
Muthusamy PD, Sundaraj K, Abd Manap N. Computerized acoustical techniques for respiratory flow-sound analysis: a systematic review. Artif Intell Rev 2019. [DOI: 10.1007/s10462-019-09769-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
9
|
Nabi FG, Sundaraj K, Lam CK. Identification of asthma severity levels through wheeze sound characterization and classification using integrated power features. Biomed Signal Process Control 2019. [DOI: 10.1016/j.bspc.2019.04.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
10
|
Ghulam Nabi F, Sundaraj K, Chee Kiang L, Palaniappan R, Sundaraj S. Wheeze sound analysis using computer-based techniques: a systematic review. ACTA ACUST UNITED AC 2019; 64:1-28. [PMID: 29087951 DOI: 10.1515/bmt-2016-0219] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Accepted: 08/24/2017] [Indexed: 11/15/2022]
Abstract
Wheezes are high pitched continuous respiratory acoustic sounds which are produced as a result of airway obstruction. Computer-based analyses of wheeze signals have been extensively used for parametric analysis, spectral analysis, identification of airway obstruction, feature extraction and diseases or pathology classification. While this area is currently an active field of research, the available literature has not yet been reviewed. This systematic review identified articles describing wheeze analyses using computer-based techniques on the SCOPUS, IEEE Xplore, ACM, PubMed and Springer and Elsevier electronic databases. After a set of selection criteria was applied, 41 articles were selected for detailed analysis. The findings reveal that 1) computerized wheeze analysis can be used for the identification of disease severity level or pathology, 2) further research is required to achieve acceptable rates of identification on the degree of airway obstruction with normal breathing, 3) analysis using combinations of features and on subgroups of the respiratory cycle has provided a pathway to classify various diseases or pathology that stem from airway obstruction.
Collapse
Affiliation(s)
- Fizza Ghulam Nabi
- School of Mechatronic Engineering, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia, Phone: +601111519452
| | - Kenneth Sundaraj
- Faculty of Electronics and Computer Engineering, Universiti Teknikal Malaysia Melaka (UTeM), 76100 Durian Tunggal, Melaka, Malaysia
| | - Lam Chee Kiang
- School of Mechatronic Engineering, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia
| | - Rajkumar Palaniappan
- School of Electronics Engineering, Vellore Institute of Technology (VIT), Tamil Nadu 632014, India
| | - Sebastian Sundaraj
- Department of Anesthesiology, Hospital Tengku Ampuan Rahimah (HTAR), 41200 Klang, Selangor, Malaysia
| |
Collapse
|
11
|
Weiss D, Erie C, Butera J, Copt R, Yeaw G, Harpster M, Hughes J, Salem DN. An in vitro acoustic analysis and comparison of popular stethoscopes. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2019; 12:41-52. [PMID: 30697087 PMCID: PMC6339642 DOI: 10.2147/mder.s186076] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare the performance of various commercially available stethoscopes using standard acoustic engineering criteria, under recording studio conditions. Materials and methods Eighteen stethoscopes (11 acoustic, 7 electronic) were analyzed using standard acoustic analysis techniques under professional recording studio conditions. An organic phantom that accurately simulated chest cavity acoustics was developed. Test sounds were played via a microphone embedded within it and auscultated at its surface by the stethoscopes. Recordings were made through each stethoscope’s binaurals and/or downloaded (electronic models). Recordings were analyzed using standard studio techniques and software, including assessing ambient noise (AMB) rejection. Frequency ranges were divided into those corresponding to various standard biological sounds (cardiac, respiratory, and gastrointestinal). Results Loudness and AMB rejection: Overall, electronic stethoscopes, when set to a maximum volume, exhibited greater values of perceived loudness compared to acoustic stethoscopes. Significant variation was seen in AMB rejection capability. Frequency detection: Marked variation was also seen, with some stethoscopes performing better for different ranges (eg, cardiac) vs others (eg, gastrointestinal). Conclusion The acoustic properties of stethoscopes varied considerably in loudness, AMB rejection, and frequency response. Stethoscope choice should take into account clinical conditions to be auscultated and the noise level of the environment.
Collapse
Affiliation(s)
- Daniel Weiss
- Department of Medicine, Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA, .,Bongiovi Medical & Health Technologies, Inc., Port St Lucie, FL, USA,
| | - Christine Erie
- Department of Medicine, Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA, .,Bongiovi Medical & Health Technologies, Inc., Port St Lucie, FL, USA,
| | - Joseph Butera
- Bongiovi Medical & Health Technologies, Inc., Port St Lucie, FL, USA,
| | - Ryan Copt
- Bongiovi Medical & Health Technologies, Inc., Port St Lucie, FL, USA,
| | - Glenn Yeaw
- Bongiovi Medical & Health Technologies, Inc., Port St Lucie, FL, USA,
| | - Mark Harpster
- Bongiovi Medical & Health Technologies, Inc., Port St Lucie, FL, USA,
| | - James Hughes
- Bongiovi Medical & Health Technologies, Inc., Port St Lucie, FL, USA, .,Department of Surgery, University of Mississippi Medical Center, Jackson, MS, USA
| | - Deeb N Salem
- Department of Medicine, Tufts Medical Center, Boston, MA, USA
| |
Collapse
|
12
|
Lozano-García M, Sarlabous L, Moxham J, Rafferty GF, Torres A, Jané R, Jolley CJ. Surface mechanomyography and electromyography provide non-invasive indices of inspiratory muscle force and activation in healthy subjects. Sci Rep 2018; 8:16921. [PMID: 30446712 PMCID: PMC6240075 DOI: 10.1038/s41598-018-35024-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 10/28/2018] [Indexed: 11/30/2022] Open
Abstract
The current gold standard assessment of human inspiratory muscle function involves using invasive measures of transdiaphragmatic pressure (Pdi) or crural diaphragm electromyography (oesEMGdi). Mechanomyography is a non-invasive measure of muscle vibration associated with muscle contraction. Surface electromyogram and mechanomyogram, recorded transcutaneously using sensors placed over the lower intercostal spaces (sEMGlic and sMMGlic respectively), have been proposed to provide non-invasive indices of inspiratory muscle activation, but have not been directly compared to gold standard Pdi and oesEMGdi measures during voluntary respiratory manoeuvres. To validate the non-invasive techniques, the relationships between Pdi and sMMGlic, and between oesEMGdi and sEMGlic were measured simultaneously in 12 healthy subjects during an incremental inspiratory threshold loading protocol. Myographic signals were analysed using fixed sample entropy (fSampEn), which is less influenced by cardiac artefacts than conventional root mean square. Strong correlations were observed between: mean Pdi and mean fSampEn |sMMGlic| (left, 0.76; right, 0.81), the time-integrals of the Pdi and fSampEn |sMMGlic| (left, 0.78; right, 0.83), and mean fSampEn oesEMGdi and mean fSampEn sEMGlic (left, 0.84; right, 0.83). These findings suggest that sMMGlic and sEMGlic could provide useful non-invasive alternatives to Pdi and oesEMGdi for the assessment of inspiratory muscle function in health and disease.
Collapse
Affiliation(s)
- Manuel Lozano-García
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain.
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain.
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain.
| | - Leonardo Sarlabous
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain
| | - John Moxham
- Faculty of Life Sciences & Medicine, King's College London, King's Health Partners, London, United Kingdom
| | - Gerrard F Rafferty
- King's College Hospital NHS Foundation Trust, King's Health Partners, London, United Kingdom
- Centre for Human & Applied Physiological Sciences, School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, King's Health Partners, London, United Kingdom
| | - Abel Torres
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain
| | - Raimon Jané
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain
| | - Caroline J Jolley
- King's College Hospital NHS Foundation Trust, King's Health Partners, London, United Kingdom
- Centre for Human & Applied Physiological Sciences, School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, King's Health Partners, London, United Kingdom
| |
Collapse
|
13
|
Characterization and classification of asthmatic wheeze sounds according to severity level using spectral integrated features. Comput Biol Med 2018; 104:52-61. [PMID: 30439599 DOI: 10.1016/j.compbiomed.2018.10.035] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 10/31/2018] [Accepted: 10/31/2018] [Indexed: 11/21/2022]
Abstract
OBJECTIVE This study aimed to investigate and classify wheeze sounds of asthmatic patients according to their severity level (mild, moderate and severe) using spectral integrated (SI) features. METHOD Segmented and validated wheeze sounds were obtained from auscultation recordings of the trachea and lower lung base of 55 asthmatic patients during tidal breathing manoeuvres. The segments were multi-labelled into 9 groups based on the auscultation location and/or breath phases. Bandwidths were selected based on the physiology, and a corresponding SI feature was computed for each segment. Univariate and multivariate statistical analyses were then performed to investigate the discriminatory behaviour of the features with respect to the severity levels in the various groups. The asthmatic severity levels in the groups were then classified using the ensemble (ENS), support vector machine (SVM) and k-nearest neighbour (KNN) methods. RESULTS AND CONCLUSION All statistical comparisons exhibited a significant difference (p < 0.05) among the severity levels with few exceptions. In the classification experiments, the ensemble classifier exhibited better performance in terms of sensitivity, specificity and positive predictive value (PPV). The trachea inspiratory group showed the highest classification performance compared with all the other groups. Overall, the best PPV for the mild, moderate and severe samples were 95% (ENS), 88% (ENS) and 90% (SVM), respectively. With respect to location, the tracheal related wheeze sounds were most sensitive and specific predictors of asthma severity levels. In addition, the classification performances of the inspiratory and expiratory related groups were comparable, suggesting that the samples from these locations are equally informative.
Collapse
|
14
|
Palaniappan R, Sundaraj K, Sundaraj S, Huliraj N, Revadi S. Classification of pulmonary pathology from breath sounds using the wavelet packet transform and an extreme learning machine. ACTA ACUST UNITED AC 2018; 63:383-394. [DOI: 10.1515/bmt-2016-0097] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Accepted: 04/20/2017] [Indexed: 11/15/2022]
Abstract
Abstract
Background:
Auscultation is a medical procedure used for the initial diagnosis and assessment of lung and heart diseases. From this perspective, we propose assessing the performance of the extreme learning machine (ELM) classifiers for the diagnosis of pulmonary pathology using breath sounds.
Methods:
Energy and entropy features were extracted from the breath sound using the wavelet packet transform. The statistical significance of the extracted features was evaluated by one-way analysis of variance (ANOVA). The extracted features were inputted into the ELM classifier.
Results:
The maximum classification accuracies obtained for the conventional validation (CV) of the energy and entropy features were 97.36% and 98.37%, respectively, whereas the accuracies obtained for the cross validation (CRV) of the energy and entropy features were 96.80% and 97.91%, respectively. In addition, maximum classification accuracies of 98.25% and 99.25% were obtained for the CV and CRV of the ensemble features, respectively.
Conclusion:
The results indicate that the classification accuracy obtained with the ensemble features was higher than those obtained with the energy and entropy features.
Collapse
|
15
|
Inspiratory muscle activation increases with COPD severity as confirmed by non-invasive mechanomyographic analysis. PLoS One 2017; 12:e0177730. [PMID: 28542364 PMCID: PMC5436747 DOI: 10.1371/journal.pone.0177730] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Accepted: 05/02/2017] [Indexed: 11/19/2022] Open
Abstract
There is a lack of instruments for assessing respiratory muscle activation during the breathing cycle in clinical conditions. The aim of the present study was to evaluate the usefulness of the respiratory muscle mechanomyogram (MMG) for non-invasively assessing the mechanical activation of the inspiratory muscles of the lower chest wall in both patients with chronic obstructive pulmonary disease (COPD) and healthy subjects, and to investigate the relationship between inspiratory muscle activation and pulmonary function parameters. Both inspiratory mouth pressure and respiratory muscle MMG were simultaneously recorded under two different respiratory conditions, quiet breathing and incremental ventilatory effort, in 13 COPD patients and 7 healthy subjects. The mechanical activation of the inspiratory muscles was characterised by the non-linear multistate Lempel–Ziv index (MLZ) calculated over the inspiratory time of the MMG signal. Subsequently, the efficiency of the inspiratory muscle mechanical activation was expressed as the ratio between the peak inspiratory mouth pressure to the amplitude of the mechanical activation. This activation estimated using the MLZ index correlated strongly with peak inspiratory mouth pressure throughout the respiratory protocol in both COPD patients (r = 0.80, p<0.001) and healthy (r = 0.82, p<0.001). Moreover, the greater the COPD severity in patients, the greater the level of muscle activation (r = -0.68, p = 0.001, between muscle activation at incremental ventilator effort and FEV1). Furthermore, the efficiency of the mechanical activation of inspiratory muscle was lower in COPD patients than healthy subjects (7.61±2.06 vs 20.42±10.81, respectively, p = 0.0002), and decreased with increasing COPD severity (r = 0.78, p<0.001, between efficiency of the mechanical activation at incremental ventilatory effort and FEV1). These results suggest that the respiratory muscle mechanomyogram is a good reflection of inspiratory effort and can be used to estimate the efficiency of the mechanical activation of the inspiratory muscles. Both, inspiratory muscle activation and inspiratory muscle mechanical activation efficiency are strongly correlated with the pulmonary function. Therefore, the use of the respiratory muscle mechanomyogram can improve the assessment of inspiratory muscle activation in clinical conditions, contributing to a better understanding of breathing in COPD patients.
Collapse
|
16
|
Lozano-García M, Fiz JA, Martínez-Rivera C, Torrents A, Ruiz-Manzano J, Jané R. Novel approach to continuous adventitious respiratory sound analysis for the assessment of bronchodilator response. PLoS One 2017; 12:e0171455. [PMID: 28178317 PMCID: PMC5298277 DOI: 10.1371/journal.pone.0171455] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Accepted: 01/20/2017] [Indexed: 11/19/2022] Open
Abstract
Background A thorough analysis of continuous adventitious sounds (CAS) can provide distinct and complementary information about bronchodilator response (BDR), beyond that provided by spirometry. Nevertheless, previous approaches to CAS analysis were limited by certain methodology issues. The aim of this study is to propose a new integrated approach to CAS analysis that contributes to improving the assessment of BDR in clinical practice for asthma patients. Methods Respiratory sounds and flow were recorded in 25 subjects, including 7 asthma patients with positive BDR (BDR+), assessed by spirometry, 13 asthma patients with negative BDR (BDR-), and 5 controls. A total of 5149 acoustic components were characterized using the Hilbert spectrum, and used to train and validate a support vector machine classifier, which distinguished acoustic components corresponding to CAS from those corresponding to other sounds. Once the method was validated, BDR was assessed in all participants by CAS analysis, and compared to BDR assessed by spirometry. Results BDR+ patients had a homogenous high change in the number of CAS after bronchodilation, which agreed with the positive BDR by spirometry, indicating high reversibility of airway obstruction. Nevertheless, we also found an appreciable change in the number of CAS in many BDR- patients, revealing alterations in airway obstruction that were not detected by spirometry. We propose a categorization for the change in the number of CAS, which allowed us to stratify BDR- patients into three consistent groups. From the 13 BDR- patients, 6 had a high response, similar to BDR+ patients, 4 had a noteworthy medium response, and 1 had a low response. Conclusions In this study, a new non-invasive and integrated approach to CAS analysis is proposed as a high-sensitive tool for assessing BDR in terms of acoustic parameters which, together with spirometry parameters, contribute to improving the stratification of BDR levels in patients with obstructive pulmonary diseases.
Collapse
Affiliation(s)
- Manuel Lozano-García
- Biomedical Signal Processing and Interpretation Group, Institute for Bioengineering of Catalonia (IBEC), Barcelona, Spain.,Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
| | - José Antonio Fiz
- Biomedical Signal Processing and Interpretation Group, Institute for Bioengineering of Catalonia (IBEC), Barcelona, Spain.,Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain.,Pulmonology Service, Germans Trias i Pujol University Hospital, Badalona, Spain
| | | | - Aurora Torrents
- Pulmonology Service, Germans Trias i Pujol University Hospital, Badalona, Spain
| | - Juan Ruiz-Manzano
- Pulmonology Service, Germans Trias i Pujol University Hospital, Badalona, Spain
| | - Raimon Jané
- Biomedical Signal Processing and Interpretation Group, Institute for Bioengineering of Catalonia (IBEC), Barcelona, Spain.,Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain.,Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain
| |
Collapse
|
17
|
A telemedicine tool to detect pulmonary pathology using computerized pulmonary acoustic signal analysis. Appl Soft Comput 2015. [DOI: 10.1016/j.asoc.2015.05.031] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
18
|
Palaniappan R, Sundaraj K, Sundaraj S, Huliraj N, Revadi S. A novel approach to detect respiratory phases from pulmonary acoustic signals using normalised power spectral density and fuzzy inference system. CLINICAL RESPIRATORY JOURNAL 2015; 10:486-94. [DOI: 10.1111/crj.12250] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2014] [Revised: 11/11/2014] [Accepted: 12/07/2014] [Indexed: 11/29/2022]
Affiliation(s)
| | - Kenneth Sundaraj
- AI-Rehab Research Group; Universiti Malaysia Perlis; Arau Malaysia
| | | | - N. Huliraj
- Department of Pulmonary Medicine; Kempegowda Institute of Medical Sciences; Bangalore India
| | - S.S. Revadi
- Department of Pulmonary Medicine; Kempegowda Institute of Medical Sciences; Bangalore India
| |
Collapse
|
19
|
Palaniappan R, Sundaraj K, Sundaraj S. A comparative study of the SVM and K-nn machine learning algorithms for the diagnosis of respiratory pathologies using pulmonary acoustic signals. BMC Bioinformatics 2014; 15:223. [PMID: 24970564 PMCID: PMC4094993 DOI: 10.1186/1471-2105-15-223] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Accepted: 06/18/2014] [Indexed: 11/24/2022] Open
Abstract
Background Pulmonary acoustic parameters extracted from recorded respiratory sounds provide valuable information for the detection of respiratory pathologies. The automated analysis of pulmonary acoustic signals can serve as a differential diagnosis tool for medical professionals, a learning tool for medical students, and a self-management tool for patients. In this context, we intend to evaluate and compare the performance of the support vector machine (SVM) and K-nearest neighbour (K-nn) classifiers in diagnosis respiratory pathologies using respiratory sounds from R.A.L.E database. Results The pulmonary acoustic signals used in this study were obtained from the R.A.L.E lung sound database. The pulmonary acoustic signals were manually categorised into three different groups, namely normal, airway obstruction pathology, and parenchymal pathology. The mel-frequency cepstral coefficient (MFCC) features were extracted from the pre-processed pulmonary acoustic signals. The MFCC features were analysed by one-way ANOVA and then fed separately into the SVM and K-nn classifiers. The performances of the classifiers were analysed using the confusion matrix technique. The statistical analysis of the MFCC features using one-way ANOVA showed that the extracted MFCC features are significantly different (p < 0.001). The classification accuracies of the SVM and K-nn classifiers were found to be 92.19% and 98.26%, respectively. Conclusion Although the data used to train and test the classifiers are limited, the classification accuracies found are satisfactory. The K-nn classifier was better than the SVM classifier for the discrimination of pulmonary acoustic signals from pathological and normal subjects obtained from the RALE database.
Collapse
Affiliation(s)
- Rajkumar Palaniappan
- AI-Rehab Research Group, Kampus Pauh Putra, Universiti Malaysia Perlis (UniMAP), Perlis, Malaysia.
| | | | | |
Collapse
|