1
|
Guo J, Teymur A, Tang C, Saxena R, Wu T. Advancing Point-of-Care Diagnosis: Digitalizing Combinatorial Biomarker Signals for Lupus Nephritis. BIOSENSORS 2024; 14:147. [PMID: 38534254 DOI: 10.3390/bios14030147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/11/2024] [Accepted: 03/13/2024] [Indexed: 03/28/2024]
Abstract
To improve the efficiency and patient coverage of the current healthcare system, user-friendly novel homecare devices are urgently needed. In this work, we developed a smartphone-based analyzing and reporting system (SBARS) for biomarker detection in lupus nephritis (LN). This system offers a cost-effective alternative to traditional, expensive large equipment in signal detection and quantification. This innovative approach involves using a portable and affordable microscopic reader to capture biomarker signals. Through smartphone-based image processing techniques, the intensity of each biomarker signal is analyzed. This system exhibited comparable performance to a commercial Genepix scanner in the detection of two potential novel biomarkers of LN, VISG4 and TNFRSF1b. Importantly, this smartphone-based analyzing and reporting system allows for discriminating LN patients with active renal disease from healthy controls with the area-under-the-curve (AUC) value = 0.9 for TNFRSF1b and 1.0 for VSIG4, respectively, indicating high predictive accuracy.
Collapse
Affiliation(s)
- Jiechang Guo
- Department of Biomedical Engineering, University of Houston, Houston, TX 77024, USA
- Department of Computer Science, University of Houston, Houston, TX 77024, USA
| | - Aygun Teymur
- Department of Biomedical Engineering, University of Houston, Houston, TX 77024, USA
| | - Chenling Tang
- Department of Biomedical Engineering, University of Houston, Houston, TX 77024, USA
| | - Ramesh Saxena
- Department of Internal Medicine, UT Southwestern Medical Center, Dallas, TX 75390, USA
| | - Tianfu Wu
- Department of Biomedical Engineering, University of Houston, Houston, TX 77024, USA
| |
Collapse
|
2
|
Dikici E, Önal Acet B, Acet Ö, Odabaşı M. “Lab-on-pol” colormatic sensor platforms: Melamine detection with color change on melamine imprinted membranes. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
3
|
Yang G, Li Y, Tang C, Lin F, Wu T, Bao J. Smartphone-Based Quantitative Analysis of Protein Array Signals for Biomarker Detection in Lupus. CHEMOSENSORS (BASEL, SWITZERLAND) 2022; 10:330. [PMID: 36072130 PMCID: PMC9447405 DOI: 10.3390/chemosensors10080330] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Fluorescence-based microarray offers great potential in clinical diagnostics due to its high-throughput capability, multiplex capabilities, and requirement for a minimal volume of precious clinical samples. However, the technique relies on expensive and complex imaging systems for the analysis of signals. In the present study, we developed a smartphone-based application to analyze signals from protein microarrays to quantify disease biomarkers. The application adopted Android Studio open platform for its wide access to smartphones, and Python was used to design a graphical user interface with fast data processing. The application provides multiple user functions such as "Read", "Analyze", "Calculate" and "Report". For rapid and accurate results, we used ImageJ, Otsu thresholding, and local thresholding to quantify the fluorescent intensity of spots on the microarray. To verify the efficacy of the application, three antigens each with over 110 fluorescent spots were tested. Particularly, a positive correlation of over 0.97 was achieved when using this analytical tool compared to a standard test for detecting a potential biomarker in lupus nephritis. Collectively, this smartphone application tool shows promise for cheap, efficient, and portable on-site detection in point-of-care diagnostics.
Collapse
Affiliation(s)
- Guang Yang
- Materials Science & Engineering, University of Houston, Houston, TX 77204, USA
| | - Yaxi Li
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Chenling Tang
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Feng Lin
- Department of Electrical and Computer Engineering, Texas Center for Superconductivity (TCSUH), University of Houston, Houston, TX 77204, USA
| | - Tianfu Wu
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Jiming Bao
- Materials Science & Engineering, University of Houston, Houston, TX 77204, USA
- Department of Electrical and Computer Engineering, Texas Center for Superconductivity (TCSUH), University of Houston, Houston, TX 77204, USA
| |
Collapse
|
4
|
Microsphere Peptide-Based Immunoassay for the Detection of Recombinant Bovine Somatotropin in Injection Preparations. BIOSENSORS 2022; 12:bios12030138. [PMID: 35323408 PMCID: PMC8946150 DOI: 10.3390/bios12030138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 01/27/2022] [Accepted: 02/11/2022] [Indexed: 12/02/2022]
Abstract
The use of peptides in immunoassays can be favored over the use of the full protein when more cost effective or less toxic approaches are needed, or when access to the full protein is lacking. Due to restricted access to recombinant bovine somatotropin (rbST), a protein enhancing growth and lactating performances of livestock, which use has been banned in the EU, Canada and Australia (amongst others), we developed a peptide-based biorecognition assay on an imaging planar array analyzer. For this, we identified the rbST epitope that is responsible for binding to the rbST-targeting monoclonal antibody 4H12 (MAb 4H12) to be 115DLEEGILALMR125. This linear peptide was synthesized and coupled to microspheres, after which it was tested in a biorecognition competitive inhibition assay format. We observed IC50 values of approximately 0.11 μg mL−1, which are lower than observed for the full rbST protein (IC50 = 0.20 μg mL−1). Importantly, there was no binding with the scrambled peptide. Preliminary results of directly coupled peptides in a microsphere biorecognition assay for detection of rbST are presented. Real-life applicability for detection of somatotropins (STs) in injection preparations of bovine-, porcine- and equine ST are shown. This newly developed immunoassay strongly supports future developments of peptide-based immunoassays to circumvent the limited access to the full protein.
Collapse
|
5
|
Raux A, Bichon E, Benedetto A, Pezzolato M, Bozzetta E, Le Bizec B, Dervilly G. The Promise and Challenges of Determining Recombinant Bovine Growth Hormone in Milk. Foods 2022; 11:foods11030274. [PMID: 35159426 PMCID: PMC8834339 DOI: 10.3390/foods11030274] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 01/12/2022] [Accepted: 01/17/2022] [Indexed: 11/27/2022] Open
Abstract
Recombinant bovine growth hormone (rbGH) is produced in large quantities and widely used in a number of countries worldwide to stimulate milk production in dairy animals. The use of this compound in animal production is strictly regulated by food safety directives in force, in particular in the European Union (EU). Although analytical strategies for the detection of rbGH in blood have been successfully reported over the past 15 years, they do not fully answer the expectations of either competent authorities or industrials that would expect measuring its occurrence directly in the milk. As a matrix of excretion but also of consumption, milk appears indeed as the matrix of choice for detecting the use of rbGH in dairy animals. It also allows large volumes to be collected without presenting an invasive character for the animal. However, rbGH detection in milk presents several challenges, mainly related to the sensitivity required for its detection in a complex biological matrix. This review article presents the specific difficulties associated with milk and provides an overview of the analytical strategies reported in the literature and whether they concern indirect or direct approaches to the detection of rbGH administration to animals, with applications either for screening or confirmation purposes.
Collapse
Affiliation(s)
- Axel Raux
- Oniris, INRAE, LABERCA, 44300 Nantes, France; (A.R.); (E.B.); (B.L.B.)
| | - Emmanuelle Bichon
- Oniris, INRAE, LABERCA, 44300 Nantes, France; (A.R.); (E.B.); (B.L.B.)
| | - Alessandro Benedetto
- Istituto Zooprofilattico Sperimentale Del Piemonte, Liguria e Valle D’Aosta, Via Bologna 148, 10154 Torino, Italy; (A.B.); (M.P.); (E.B.)
| | - Marzia Pezzolato
- Istituto Zooprofilattico Sperimentale Del Piemonte, Liguria e Valle D’Aosta, Via Bologna 148, 10154 Torino, Italy; (A.B.); (M.P.); (E.B.)
| | - Elena Bozzetta
- Istituto Zooprofilattico Sperimentale Del Piemonte, Liguria e Valle D’Aosta, Via Bologna 148, 10154 Torino, Italy; (A.B.); (M.P.); (E.B.)
| | - Bruno Le Bizec
- Oniris, INRAE, LABERCA, 44300 Nantes, France; (A.R.); (E.B.); (B.L.B.)
| | - Gaud Dervilly
- Oniris, INRAE, LABERCA, 44300 Nantes, France; (A.R.); (E.B.); (B.L.B.)
- Correspondence: ; Tel.: +33-2-40-68-78-80
| |
Collapse
|
6
|
Thompson AJ, Bourke CD, Robertson RC, Shivakumar N, Edwards CA, Preston T, Holmes E, Kelly P, Frost G, Morrison DJ. Understanding the role of the gut in undernutrition: what can technology tell us? Gut 2021; 70:gutjnl-2020-323609. [PMID: 34103403 PMCID: PMC8292602 DOI: 10.1136/gutjnl-2020-323609] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 05/04/2021] [Indexed: 12/22/2022]
Abstract
Gut function remains largely underinvestigated in undernutrition, despite its critical role in essential nutrient digestion, absorption and assimilation. In areas of high enteropathogen burden, alterations in gut barrier function and subsequent inflammatory effects are observable but remain poorly characterised. Environmental enteropathy (EE)-a condition that affects both gut morphology and function and is characterised by blunted villi, inflammation and increased permeability-is thought to play a role in impaired linear growth (stunting) and severe acute malnutrition. However, the lack of tools to quantitatively characterise gut functional capacity has hampered both our understanding of gut pathogenesis in undernutrition and evaluation of gut-targeted therapies to accelerate nutritional recovery. Here we survey the technology landscape for potential solutions to improve assessment of gut function, focussing on devices that could be deployed at point-of-care in low-income and middle-income countries (LMICs). We assess the potential for technological innovation to assess gut morphology, function, barrier integrity and immune response in undernutrition, and highlight the approaches that are currently most suitable for deployment and development. This article focuses on EE and undernutrition in LMICs, but many of these technologies may also become useful in monitoring of other gut pathologies.
Collapse
Affiliation(s)
- Alex J Thompson
- Hamlyn Centre for Robotic Surgery, Department of Surgery and Cancer, Imperial College London, London, UK
| | - Claire D Bourke
- Blizard Institute, Barts & The London School of Medicine, Queen Mary University of London, London, UK
| | - Ruairi C Robertson
- Blizard Institute, Barts & The London School of Medicine, Queen Mary University of London, London, UK
| | - Nirupama Shivakumar
- Division of Nutrition, St John's National Academy of Health Sciences, Bangalore, Karnataka, India
| | | | - Tom Preston
- Stable Isotope Biochemistry Laboratory, Scottish Universities Environmental Research Centre, East Kilbride, UK
| | - Elaine Holmes
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Paul Kelly
- Blizard Institute, Barts & The London School of Medicine, Queen Mary University of London, London, UK
- Tropical Gastroenterology and Nutrition Group, University of Zambia School of Medicine, Lusaka, Zambia
| | - Gary Frost
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Douglas J Morrison
- Stable Isotope Biochemistry Laboratory, Scottish Universities Environmental Research Centre, East Kilbride, UK
| |
Collapse
|
7
|
Abstract
During the past few decades, there has been a growing trend towards the use of smartphone-based analysis systems. This is mainly due to its ubiquity, its increasing computing capacity, its relatively low cost and the ability to acquire and process data at the same time. Furthermore, there are many sensors integrated into a smartphone, for example a complementary metal-oxide semiconductor (CMOS) sensor. A CMOS sensor enables optical analysis for example by using it as a colorimeter, photometer or spectrometer. This review explores the current state-of-the-art smartphone-based optical analysis systems in various areas of application. It is organized into three sections, each of which investigates one class of smartphone-based devices: (i) smartphone-based colorimeters (ii) smartphone-based photo- and spectrometers and (iii) smartphone-based fluorimeters.
Collapse
Affiliation(s)
- Sarah Di Nonno
- TU Kaiserslautern, Chair of Bioprocess Engineering, Kaiserslautern, Germany.
| | - Roland Ulber
- TU Kaiserslautern, Chair of Bioprocess Engineering, Kaiserslautern, Germany.
| |
Collapse
|
8
|
Sami MA, Tayyab M, Parikh P, Govindaraju H, Hassan U. A modular microscopic smartphone attachment for imaging and quantification of multiple fluorescent probes using machine learning. Analyst 2021; 146:2531-2541. [PMID: 33899061 DOI: 10.1039/d0an02451a] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Portable smartphone-based fluorescent microscopes are becoming popular owing to their ability to provide major functionalities offered by regular benchtop microscopes at a fraction of the cost. However, smartphone-based microscopes are still limited to a single fluorophore, fixed magnification, the inability to work with a different smartphones, and limited usability to either glass slides or cover slips. To overcome these challenges, here we present a modular smartphone-based microscopic attachment. The modular design allows the user to easily swap between different sets of filters and lenses, thereby enabling utility of multiple fluorophores and magnification levels. Our microscopic smartphone attachment can also be used with different smartphones and was tested with Nokia Lumia 1020, Samsung Galaxy S9+, and an iPhone XS. Further, we showed imaging results of samples on glass slides, cover slips, and microfluidic devices. A 1951 USAF resolution test target was used to quantify the maximum resolution of the microscope which was found to be 3.9 μm. The performance of the smartphone-based microscope was compared with a benchtop microscope and we found an R2 value of 0.99 using polystyrene beads and blood cells isolated from human blood samples collected from Robert Wood Johnson Medical Hospital. Additionally, to count the particles (cells and beads) imaged from the smartphone-based fluorescent microscope, we developed artificial neural networks (ANNs) using multiple training algorithms, and evaluated their performances compared to the control (ImageJ). Finally, we did ANOVA and Tukey's post-hoc analysis and found a p-value of 0.97 which shows that no statistical significant difference exists between the performance of the trained ANN and control (ImageJ).
Collapse
Affiliation(s)
- Muhammad A Sami
- Department of Electrical and Computer Engineering, School of Engineering, Rutgers The State University of New Jersey, Piscataway, NJ, USA.
| | - Muhammad Tayyab
- Department of Electrical and Computer Engineering, School of Engineering, Rutgers The State University of New Jersey, Piscataway, NJ, USA.
| | - Priya Parikh
- Department of Electrical and Computer Engineering, School of Engineering, Rutgers The State University of New Jersey, Piscataway, NJ, USA.
| | - Harshitha Govindaraju
- Department of Biomedical Engineering, School of Engineering, Rutgers The State University of New Jersey, Piscataway, NJ, USA
| | - Umer Hassan
- Department of Electrical and Computer Engineering, School of Engineering, Rutgers The State University of New Jersey, Piscataway, NJ, USA. and Global Health Institute, Rutgers The State University of New Jersey, New Brunswick, NJ, USA
| |
Collapse
|
9
|
Smits NGE, Blokland MH, Wubs KL, Bovee TFH, Albada B, van Ginkel LA, Nielen MWF. Detection of methionine- and alanine-recombinant bovine somatotropins and their induced antibodies in serum and milk of cows suggests blood-milk barrier specificity for these compounds. J Dairy Sci 2021; 104:5069-5078. [PMID: 33663857 DOI: 10.3168/jds.2020-19209] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Accepted: 10/16/2020] [Indexed: 11/19/2022]
Abstract
The elimination of recombinant bovine somatotropin (rbST) and its induced antibodies through milk of 2 formulations is studied to propose a control strategy for its use or abuse. Two dairy cows were treated with alanine-rbST (Ala-rbST), which is identical to endogenous bovine somatotropin, and ten dairy cows were treated with methionine-rbST (Met-rbST), which differs by 1 amino acid from endogenous bovine somatotropin. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method able to measure rbST at a decision limit (CCα) of 0.8 ng/mL and 2.3 ng/mL for serum and milk, respectively. The results show that the administered Ala-rbST is transferred from blood to milk but that this is not the case for Met-rbST. This suggests a blood-milk barrier-related specificity for these compounds. In addition, rbST-induced antibodies were formed in animals treated with Ala-rbST and those treated with Met-rbST. In both treatments, the rbST-induced antibodies were transferred from blood to milk, showing no blood-milk barrier specificity for these antibodies. These elimination patterns show that, for enforcement purposes, the detection of rbST-induced antibodies in tank milk can serve to screen for rbST administration, and subsequent confirmatory serum analysis by LC-MS/MS is needed to identify whether Ala-rbST or Met-rbST has been used.
Collapse
Affiliation(s)
- Nathalie G E Smits
- Wageningen Food Safety Research, Wageningen University and Research, 6700 AE Wageningen, the Netherlands.
| | - Marco H Blokland
- Wageningen Food Safety Research, Wageningen University and Research, 6700 AE Wageningen, the Netherlands
| | - Klaas L Wubs
- Wageningen Food Safety Research, Wageningen University and Research, 6700 AE Wageningen, the Netherlands
| | - Toine F H Bovee
- Wageningen Food Safety Research, Wageningen University and Research, 6700 AE Wageningen, the Netherlands
| | - Bauke Albada
- Laboratory of Organic Chemistry, Wageningen University and Research, 6708 WE Wageningen, the Netherlands
| | - Leendert A van Ginkel
- Wageningen Food Safety Research, Wageningen University and Research, 6700 AE Wageningen, the Netherlands
| | - Michel W F Nielen
- Wageningen Food Safety Research, Wageningen University and Research, 6700 AE Wageningen, the Netherlands; Laboratory of Organic Chemistry, Wageningen University and Research, 6708 WE Wageningen, the Netherlands
| |
Collapse
|
10
|
FEAST of biosensors: Food, environmental and agricultural sensing technologies (FEAST) in North America. Biosens Bioelectron 2021; 178:113011. [PMID: 33517232 DOI: 10.1016/j.bios.2021.113011] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 01/04/2021] [Accepted: 01/16/2021] [Indexed: 02/08/2023]
Abstract
We review the challenges and opportunities for biosensor research in North America aimed to accelerate translational research. We call for platform approaches based on: i) tools that can support interoperability between food, environment and agriculture, ii) open-source tools for analytics, iii) algorithms used for data and information arbitrage, and iv) use-inspired sensor design. We summarize select mobile devices and phone-based biosensors that couple analytical systems with biosensors for improving decision support. Over 100 biosensors developed by labs in North America were analyzed, including lab-based and portable devices. The results of this literature review show that nearly one quarter of the manuscripts focused on fundamental platform development or material characterization. Among the biosensors analyzed for food (post-harvest) or environmental applications, most devices were based on optical transduction (whether a lab assay or portable device). Most biosensors for agricultural applications were based on electrochemical transduction and few utilized a mobile platform. Presently, the FEAST of biosensors has produced a wealth of opportunity but faces a famine of actionable information without a platform for analytics.
Collapse
|
11
|
Antibody Printing Technologies. Methods Mol Biol 2020. [PMID: 33237416 DOI: 10.1007/978-1-0716-1064-0_13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
Antibody microarrays are routinely employed in the lab and in the clinic for studying protein expression, protein-protein, and protein-drug interactions. The microarray format reduces the size scale at which biological and biochemical interactions occur, leading to large reductions in reagent consumption and handling times while increasing overall experimental throughput. Specifically, antibody microarrays, as a platform, offer a number of different advantages over traditional techniques in the areas of drug discovery and diagnostics. While a number of different techniques and approaches have been developed for creating micro and nanoscale antibody arrays, issues relating to sensitivity, cost, and reproducibility persist. The aim of this review is to highlight current state-of the-art techniques and approaches for creating antibody arrays by providing latest accounts of the field while discussing potential future directions.
Collapse
|
12
|
Validation of a Rapid Bronchoalveolar Lavage Fluid Colorimetric Evaluation for Assessing the Severity of Exercise-Induced Pulmonary Hemorrhage in Horses in Field Conditions. J Equine Vet Sci 2020; 95:103284. [PMID: 33276915 DOI: 10.1016/j.jevs.2020.103284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 08/22/2020] [Accepted: 09/29/2020] [Indexed: 11/24/2022]
Abstract
Diagnosis and assessment of severity of exercise-induced pulmonary hemorrhage (EIPH) relies on postexercise visualization of fresh blood in the airways via tracheobronchoscopic examination (TBE) and/or counting erythrocytes in bronchoalveolar lavage fluid (BALFRBC). Determining the BALFRBC is more sensitive than TBE but its usefulness is hampered by the need to have BALFRBC counted at a laboratory. We explored the feasibility of evaluating the severity of EIPH by using a color chart comprised of five shades of red and matching those colors with the color of BALF immediately following collection. To validate the technique, sets of ten BALF samples with known BALFRBC numbers were created and randomly shown to two groups of 18 observers who independently matched the color of the BALF with one of the shades of red displayed on the screen of a smartphone. Interobserver and intra-observer agreements regarding colors were > 0.9. The utility of the color chart was further validated under field conditions at two barrel racing events where 63 BALF samples were collected from 21 horses and BALF color was graded independently by three observers. The number of BALFRBC in the 63 samples ranged from 25-1,100,000/μL. EIPH was diagnosed in 39 samples based on the detection of color, and all 5 colors were matched multiple times with BALF samples. Overall, the color of the BALF was related to the number of BALFRBC. Colorimetric evaluation of BALF represents a practical and reliable option for rapid postexercise assessment of the presence and severity of EIPH.
Collapse
|
13
|
Aydindogan E, Ceylan AE, Timur S. Paper-based colorimetric spot test utilizing smartphone sensing for detection of biomarkers. Talanta 2020; 208:120446. [DOI: 10.1016/j.talanta.2019.120446] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 10/01/2019] [Accepted: 10/04/2019] [Indexed: 01/27/2023]
|
14
|
Nehra M, Lettieri M, Dilbaghi N, Kumar S, Marrazza G. Nano-Biosensing Platforms for Detection of Cow's Milk Allergens: An Overview. SENSORS (BASEL, SWITZERLAND) 2019; 20:E32. [PMID: 31861555 PMCID: PMC6982970 DOI: 10.3390/s20010032] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 12/07/2019] [Accepted: 12/16/2019] [Indexed: 12/16/2022]
Abstract
Among prevalent food allergies, cow milk allergy (CMA) is most common and may persist throughout the life. The allergic individuals are exposed to a constant threat due to milk proteins' presence in uncounted food products like yogurt, cheese, and bakery items. The problem can be more severe due to cross-reactivity of the milk allergens in the food products due to homologous milk proteins of diverse species. This problem can be overcome by proper and reliable food labeling in order to ensure the life quality of allergic persons. Therefore, highly sensitive and accurate analytical techniques should be developed to detect the food allergens. Here, significant research advances in biosensors (specifically immunosensors and aptasensors) are reviewed for detection of the milk allergens. Different allergic proteins of cow milk are described here along with the analytical standard methods for their detection. Additionally, the commercial status of biosensors is also discussed in comparison to conventional techniques like enzyme-linked immunosorbent assay (ELISA). The development of novel biosensing mechanisms/kits for milk allergens detection is imperative from the perspective of enforcement of labeling regulations and directives keeping in view the sensitive individuals.
Collapse
Affiliation(s)
- Monika Nehra
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India; (M.N.)
| | - Mariagrazia Lettieri
- Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia, 350019 Sesto Fiorentino (Fi), Italy;
| | - Neeraj Dilbaghi
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India; (M.N.)
| | - Sandeep Kumar
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India; (M.N.)
| | - Giovanna Marrazza
- Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia, 350019 Sesto Fiorentino (Fi), Italy;
| |
Collapse
|
15
|
Nelis JLD, Bura L, Zhao Y, Burkin KM, Rafferty K, Elliott CT, Campbell K. The Efficiency of Color Space Channels to Quantify Color and Color Intensity Change in Liquids, pH Strips, and Lateral Flow Assays with Smartphones. SENSORS 2019; 19:s19235104. [PMID: 31766483 PMCID: PMC6928750 DOI: 10.3390/s19235104] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 11/14/2019] [Accepted: 11/19/2019] [Indexed: 01/26/2023]
Abstract
Bottom-up, end-user based feed, and food analysis through smartphone quantification of lateral flow assays (LFA) has the potential to cause a paradigm shift in testing capabilities. However, most developed devices do not test the presence of and implications of inter-phone variation. Much discussion remains regarding optimum color space for smartphone colorimetric analyses and, an in-depth comparison of color space performance is missing. Moreover, a light-shielding box is often used to avoid variations caused by background illumination while the use of such a bulky add-on may be avoidable through image background correction. Here, quantification performance of individual channels of RGB, HSV, and LAB color space and ΔRGB was determined for color and color intensity variation using pH strips, filter paper with dropped nanoparticles, and colored solutions. LAB and HSV color space channels never outperformed the best RGB channels in any test. Background correction avoided measurement variation if no direct sunlight was used and functioned more efficiently outside a light-shielding box (prediction errors < 5%/35% for color/color intensity change). The system was validated using various phones for quantification of major allergens (i.e., gluten in buffer, bovine milk in goat milk and goat cheese), and, pH in soil extracts with commercial pH strips and LFA. Inter-phone variation was significant for LFA quantification but low using pH strips (prediction errors < 10% for all six phones compared). Thus, assays based on color change hold the strongest promise for end-user adapted smartphone diagnostics.
Collapse
Affiliation(s)
- Joost Laurus Dinant Nelis
- Institute for Global Food Security, School of Biological Sciences, Queen’s University of Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, UK; (Y.Z.); (C.T.E.)
- Correspondence: (J.L.D.N.); (K.C.)
| | - Laszlo Bura
- Department of Food and Drug, University of Parma, Parco Area delle Scienze 27/A, 43124 Parma, Italy;
| | - Yunfeng Zhao
- Institute for Global Food Security, School of Biological Sciences, Queen’s University of Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, UK; (Y.Z.); (C.T.E.)
- School of Electronics, Electrical Engineering and Computer Science, Queen’s University Belfast, 125 Stranmillis Road, Belfast BT9 5AH, UK;
| | - Konstantin M. Burkin
- Faculty of Chemistry, Lomonosov Moscow State University, 1-3 Leninskiye Gory, GSP-1, Moscow 119991, Russia;
| | - Karen Rafferty
- School of Electronics, Electrical Engineering and Computer Science, Queen’s University Belfast, 125 Stranmillis Road, Belfast BT9 5AH, UK;
| | - Christopher T. Elliott
- Institute for Global Food Security, School of Biological Sciences, Queen’s University of Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, UK; (Y.Z.); (C.T.E.)
| | - Katrina Campbell
- Institute for Global Food Security, School of Biological Sciences, Queen’s University of Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, UK; (Y.Z.); (C.T.E.)
- Correspondence: (J.L.D.N.); (K.C.)
| |
Collapse
|
16
|
Lamas A, Regal P, Vázquez B, Miranda JM, Cepeda A, Franco CM. Tracing recombinant bovine somatotropin ab(use) through transcriptomics: the potential of bovine somatic cells in a multi-dose longitudinal study. Sci Rep 2019; 9:4788. [PMID: 30886250 PMCID: PMC6423037 DOI: 10.1038/s41598-019-41343-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 03/07/2019] [Indexed: 12/15/2022] Open
Abstract
In the European Union, the use of recombinant bovine somatotropin (rbST) in dairy cattle is forbidden. Monitoring rbST (ab)use by its direct detection in animal matrices still remains a challenging task. New monitoring methods based on indirect detection of the substance are necessary. A new transcriptomic system based on the use of high-throughput real-time PCR in combination with somatic cells was developed to control rbST administration in dairy animals. A total of nine cows, separated into control and rbST-treated groups, were included in the study. A subcutaneous injection containing 500 mg of rbST was administered to the treated group every 14 days, up to a total of 12 doses. Milk somatic cells (MSCs) were sampled from each animal at different time points throughout 8 months of study. It was possible to obtain the transcriptomic profile of 18 genes in MSCs of rbST-treated and control groups, and using univariate and multivariate statistical analysis control and treated animals were discriminated. The transcription of CCND1, IGF-1R, TNF and IL-1β genes resulted strongly influenced by rbST treatment. The combination of MSCs, transcriptomic tools and statistical analysis has allowed the selection of four genes as potential biomarkers that could be used in a transcriptomic panel for monitoring rbST administration in cows.
Collapse
Affiliation(s)
- Alexandre Lamas
- Laboratorio de Higiene Inspección y Control de Alimentos. Departamento de Química Analítica, Nutrición y Bromatología. Universidade de Santiago de Compostela, 27002, Lugo, Spain.
| | - Patricia Regal
- Laboratorio de Higiene Inspección y Control de Alimentos. Departamento de Química Analítica, Nutrición y Bromatología. Universidade de Santiago de Compostela, 27002, Lugo, Spain
| | - Beatriz Vázquez
- Laboratorio de Higiene Inspección y Control de Alimentos. Departamento de Química Analítica, Nutrición y Bromatología. Universidade de Santiago de Compostela, 27002, Lugo, Spain
| | - José Manuel Miranda
- Laboratorio de Higiene Inspección y Control de Alimentos. Departamento de Química Analítica, Nutrición y Bromatología. Universidade de Santiago de Compostela, 27002, Lugo, Spain
| | - Alberto Cepeda
- Laboratorio de Higiene Inspección y Control de Alimentos. Departamento de Química Analítica, Nutrición y Bromatología. Universidade de Santiago de Compostela, 27002, Lugo, Spain
| | - Carlos Manuel Franco
- Laboratorio de Higiene Inspección y Control de Alimentos. Departamento de Química Analítica, Nutrición y Bromatología. Universidade de Santiago de Compostela, 27002, Lugo, Spain
| |
Collapse
|
17
|
Choi JR, Yong KW, Choi JY, Cowie AC. Emerging Point-of-care Technologies for Food Safety Analysis. SENSORS (BASEL, SWITZERLAND) 2019; 19:817. [PMID: 30781554 PMCID: PMC6412947 DOI: 10.3390/s19040817] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 02/14/2019] [Accepted: 02/14/2019] [Indexed: 02/08/2023]
Abstract
Food safety issues have recently attracted public concern. The deleterious effects of compromised food safety on health have rendered food safety analysis an approach of paramount importance. While conventional techniques such as high-performance liquid chromatography and mass spectrometry have traditionally been utilized for the detection of food contaminants, they are relatively expensive, time-consuming and labor intensive, impeding their use for point-of-care (POC) applications. In addition, accessibility of these tests is limited in developing countries where food-related illnesses are prevalent. There is, therefore, an urgent need to develop simple and robust diagnostic POC devices. POC devices, including paper- and chip-based devices, are typically rapid, cost-effective and user-friendly, offering a tremendous potential for rapid food safety analysis at POC settings. Herein, we discuss the most recent advances in the development of emerging POC devices for food safety analysis. We first provide an overview of common food safety issues and the existing techniques for detecting food contaminants such as foodborne pathogens, chemicals, allergens, and toxins. The importance of rapid food safety analysis along with the beneficial use of miniaturized POC devices are subsequently reviewed. Finally, the existing challenges and future perspectives of developing the miniaturized POC devices for food safety monitoring are briefly discussed.
Collapse
Affiliation(s)
- Jane Ru Choi
- Department of Mechanical Engineering, University of British Columbia, 2054⁻6250 Applied Science Lane, Vancouver, BC V6T 1Z4, Canada.
- Centre for Blood Research, Life Sciences Centre, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada.
| | - Kar Wey Yong
- Department of Chemical & Petroleum Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
| | - Jean Yu Choi
- Faculty of Medicine, University of Dundee, Dow Street, Dundee DD1 5EH, UK.
| | - Alistair C Cowie
- Faculty of Medicine, University of Dundee, Dow Street, Dundee DD1 5EH, UK.
| |
Collapse
|
18
|
Taghavian O, Jain A, Joyner CJ, Ketchum S, Nakajima R, Jasinskas A, Liang L, Fong R, King C, Greenhouse B, Murphy M, Bailey J, Galinski MR, Barnwell JW, Plowe CV, Davies DH, Felgner PL. Antibody Profiling by Proteome Microarray with Multiplex Isotype Detection Reveals Overlap between Human and Aotus nancymaae Controlled Malaria Infections. Proteomics 2019; 18. [PMID: 29266845 DOI: 10.1002/pmic.201700277] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Revised: 11/21/2017] [Indexed: 12/13/2022]
Abstract
The development of vaccines against malaria and serodiagnostic tests for detecting recent exposure requires tools for antigen discovery and suitable animal models. The protein microarray is a high-throughput, sample sparing technique, with applications in infectious disease research, clinical diagnostics, epidemiology, and vaccine development. We recently demonstrated Qdot-based indirect immunofluorescence together with portable optical imager ArrayCAM using single isotype detection could replicate data using the conventional laser confocal scanner system. We developed a multiplexing protocol for simultaneous detection of IgG, IgA, and IgM and compared samples from a controlled human malaria infection model with those from controlled malaria infections of Aotus nancymaae, a widely used non-human primate model of human malaria. IgG profiles showed the highest concordance in number of reactive antigens; thus, of the 139 antigens recognized by human IgG antibody, 111 were also recognized by Aotus monkeys. Interestingly, IgA profiles were largely non-overlapping. Finally, on the path toward wider deployment of the portable platform, we show excellent correlations between array data obtained in five independent laboratories around the United States using the multiplexing protocol (R2 : 0.60-0.92). This study supports the use of this platform for wider deployment, particularly in endemic areas where such a tool will have the greatest impact on global human health.
Collapse
Affiliation(s)
- Omid Taghavian
- Department of Medicine, Division of Infectious Diseases, University of California Irvine, Irvine, CA, USA
| | - Aarti Jain
- Department of Medicine, Division of Infectious Diseases, University of California Irvine, Irvine, CA, USA
| | - Chester J Joyner
- International Center for Malaria Research, Education and Development, Emory Vaccine Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA
| | | | - Rie Nakajima
- Department of Medicine, Division of Infectious Diseases, University of California Irvine, Irvine, CA, USA
| | - Algis Jasinskas
- Department of Medicine, Division of Infectious Diseases, University of California Irvine, Irvine, CA, USA
| | - Li Liang
- Department of Medicine, Division of Infectious Diseases, University of California Irvine, Irvine, CA, USA
| | - Rich Fong
- Center for Global Health and Diseases, Case Western Reserve University, Cleveland, OH, USA
| | - Christopher King
- Center for Global Health and Diseases, Case Western Reserve University, Cleveland, OH, USA
| | - Bryan Greenhouse
- Department of Medicine, University of California, San Francisco, CA, USA
| | - Maxwell Murphy
- Department of Medicine, University of California, San Francisco, CA, USA
| | - Jason Bailey
- Division of Infectious Diseases, Department of Medicine, Emory University, Atlanta, GA, USA
| | - Mary R Galinski
- International Center for Malaria Research, Education and Development, Emory Vaccine Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA.,Division of Infectious Diseases, Department of Medicine, Emory University, Atlanta, GA, USA
| | - John W Barnwell
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - Christopher V Plowe
- Howard Hughes Medical Institute/Center for Vaccine Development, University of Maryland School of Medicine, Baltimore, MD, USA
| | - D Huw Davies
- Department of Medicine, Division of Infectious Diseases, University of California Irvine, Irvine, CA, USA
| | - Philip L Felgner
- Department of Medicine, Division of Infectious Diseases, University of California Irvine, Irvine, CA, USA
| |
Collapse
|
19
|
Vietz C, Schütte ML, Wei Q, Richter L, Lalkens B, Ozcan A, Tinnefeld P, Acuna GP. Benchmarking Smartphone Fluorescence-Based Microscopy with DNA Origami Nanobeads: Reducing the Gap toward Single-Molecule Sensitivity. ACS OMEGA 2019; 4:637-642. [PMID: 30775643 PMCID: PMC6372172 DOI: 10.1021/acsomega.8b03136] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 12/24/2018] [Indexed: 05/18/2023]
Abstract
Smartphone-based fluorescence microscopy has been rapidly developing over the last few years, enabling point-of-need detection of cells, bacteria, viruses, and biomarkers. These mobile microscopy devices are cost-effective, field-portable, and easy to use, and benefit from economies of scale. Recent developments in smartphone camera technology have improved their performance, getting closer to that of lab microscopes. Here, we report the use of DNA origami nanobeads with predefined numbers of fluorophores to quantify the sensitivity of a smartphone-based fluorescence microscope in terms of the minimum number of detectable molecules per diffraction-limited spot. With the brightness of a single dye molecule as a reference, we compare the performance of color and monochrome sensors embedded in state-of-the-art smartphones. Our results show that the monochrome sensor of a smartphone can achieve better sensitivity, with a detection limit of ∼10 fluorophores per spot. The use of DNA origami nanobeads to quantify the minimum number of detectable molecules of a sensor is broadly applicable to evaluate the sensitivity of various optical instruments.
Collapse
Affiliation(s)
- Carolin Vietz
- Institute
for Physical & Theoretical Chemistry, Braunschweig Integrated
Centre of Systems Biology (BRICS), and Laboratory for Emerging Nanometrology
(LENA), Braunschweig University of Technology, Rebenring 56, 38106 Braunschweig, Germany
| | - Max L. Schütte
- Institute
for Physical & Theoretical Chemistry, Braunschweig Integrated
Centre of Systems Biology (BRICS), and Laboratory for Emerging Nanometrology
(LENA), Braunschweig University of Technology, Rebenring 56, 38106 Braunschweig, Germany
| | - Qingshan Wei
- Department
of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Lars Richter
- Institute
for Physical & Theoretical Chemistry, Braunschweig Integrated
Centre of Systems Biology (BRICS), and Laboratory for Emerging Nanometrology
(LENA), Braunschweig University of Technology, Rebenring 56, 38106 Braunschweig, Germany
| | - Birka Lalkens
- Department
Chemie and Center for NanoScience, Ludwig-Maximilians-Universitaet
Muenchen, Butenandtstr.
5-13 Haus E, 81377 Muenchen, Germany
| | - Aydogan Ozcan
- Electrical
& Computer Engineering Department, Bioengineering Department,
California NanoSystems Institute (CNSI), and Department of Surgery, University of California, Los Angeles, Los Angeles, California 90095, United States
- E-mail: . Tel: +1 310 825 0915 (A.O.)
| | - Philip Tinnefeld
- Department
Chemie and Center for NanoScience, Ludwig-Maximilians-Universitaet
Muenchen, Butenandtstr.
5-13 Haus E, 81377 Muenchen, Germany
- E-mail: . Tel: +49 89 2180 77549. Fax: +49 89 2180 77548 (P.T.)
| | - Guillermo P. Acuna
- Institute
for Physical & Theoretical Chemistry, Braunschweig Integrated
Centre of Systems Biology (BRICS), and Laboratory for Emerging Nanometrology
(LENA), Braunschweig University of Technology, Rebenring 56, 38106 Braunschweig, Germany
- Department
of Physics, University of Fribourg, Chemin du Musée 3, Fribourg CH-1700, Switzerland
- E-mail: . Tel: +41 26 300 9631. Fax: +41 26 300 9030 (G.P.A.)
| |
Collapse
|
20
|
Zhao Z, Wei L, Cao M, Lu M. A smartphone-based system for fluorescence polarization assays. Biosens Bioelectron 2018; 128:91-96. [PMID: 30640125 DOI: 10.1016/j.bios.2018.12.031] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 12/13/2018] [Accepted: 12/14/2018] [Indexed: 01/12/2023]
Abstract
This paper demonstrates the use of a smartphone-based sensor for fluorescence polarization (FP) analysis of biomolecules. The FP detection can rapidly sense ligand-analyte bindings by measuring molecule mobility, and thus, FP-based assays have been widely used for rapid diagnostics in clinics. Here, we implemented the FP detection apparatus using a 3D-printed compact holder and the built-in camera of a smartphone. The system offers accurate measurements of the degree of polarization by simultaneously detecting the fluorescence intensities parallel and perpendicular to the polarization of the excitation. The fluorescence signal of the sample is excited by a laser or light-emitting diode and separated by a polarization beam cube depending on the polarization. Parallel and perpendicular polarized emissions are projected onto two different regions of the sensor chip in the smartphone camera. A custom software app was developed to count the average intensity in the areas of interest and compute the degree of polarization. We validated the system by measuring the polarization of dye molecules dissolved in solutions with different viscosities. As an example of biomolecule sensing, a competitive FP immunoassay of Prostaglandin E2 was demonstrated using the developed system and exhibited the limit of detection of 1.57 ng/mL. The smartphone-based FP assay platform can also be implemented for the detection of toxins, disease biomarkers, and pathogens in resource-limited settings.
Collapse
Affiliation(s)
- Zijian Zhao
- Department of Electrical and Computer Engineering, Iowa State University, Ames, IA 50011, United States
| | - Le Wei
- Department of Electrical and Computer Engineering, Iowa State University, Ames, IA 50011, United States
| | - Mingfeng Cao
- Department of Chemical and Biomolecule Engineering, Iowa State University, Ames, IA 50011, United States
| | - Meng Lu
- Department of Electrical and Computer Engineering, Iowa State University, Ames, IA 50011, United States; Department of Mechanical Engineering, Iowa State University, Ames, IA 500110, United States.
| |
Collapse
|
21
|
Ross GMS, Bremer MGEG, Wichers JH, van Amerongen A, Nielen MWF. Rapid Antibody Selection Using Surface Plasmon Resonance for High-Speed and Sensitive Hazelnut Lateral Flow Prototypes. BIOSENSORS 2018; 8:E130. [PMID: 30558252 PMCID: PMC6316566 DOI: 10.3390/bios8040130] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Revised: 12/06/2018] [Accepted: 12/12/2018] [Indexed: 12/20/2022]
Abstract
Lateral Flow Immunoassays (LFIAs) allow for rapid, low-cost, screening of many biomolecules such as food allergens. Despite being classified as rapid tests, many LFIAs take 10⁻20 min to complete. For a really high-speed LFIA, it is necessary to assess antibody association kinetics. By using a label-free optical technique such as Surface Plasmon Resonance (SPR), it is possible to screen crude monoclonal antibody (mAb) preparations for their association rates against a target. Herein, we describe an SPR-based method for screening and selecting crude anti-hazelnut antibodies based on their relative association rates, cross reactivity and sandwich pairing capabilities, for subsequent application in a rapid ligand binding assay. Thanks to the SPR selection process, only the fast mAb (F-50-6B12) and the slow (S-50-5H9) mAb needed purification for labelling with carbon nanoparticles to exploit high-speed LFIA prototypes. The kinetics observed in SPR were reflected in LFIA, with the test line appearing within 30 s, almost two times faster when F-50-6B12 was used, compared with S-50-5H9. Additionally, the LFIAs have demonstrated their future applicability to real life samples by detecting hazelnut in the sub-ppm range in a cookie matrix. Finally, these LFIAs not only provide a qualitative result when read visually, but also generate semi-quantitative data when exploiting freely downloadable smartphone apps.
Collapse
Affiliation(s)
- Georgina M S Ross
- RIKILT, Wageningen University & Research. P.O Box 230, 6700 AE Wageningen, The Netherlands.
| | - Maria G E G Bremer
- RIKILT, Wageningen University & Research. P.O Box 230, 6700 AE Wageningen, The Netherlands.
| | - Jan H Wichers
- Wageningen Food & Biobased Research, BioSensing & Diagnostics, Wageningen University & Research, P.O Box 17, 6700 AA, Wageningen, The Netherlands.
| | - Aart van Amerongen
- Wageningen Food & Biobased Research, BioSensing & Diagnostics, Wageningen University & Research, P.O Box 17, 6700 AA, Wageningen, The Netherlands.
| | - Michel W F Nielen
- RIKILT, Wageningen University & Research. P.O Box 230, 6700 AE Wageningen, The Netherlands.
- Wageningen University, Laboratory of Organic Chemistry, Helix Building 124, Stippeneng 4. 6708 WE Wageningen, The Netherlands.
| |
Collapse
|
22
|
"The Smartphone's Guide to the Galaxy": In Situ Analysis in Space. BIOSENSORS-BASEL 2018; 8:bios8040096. [PMID: 30347742 PMCID: PMC6316803 DOI: 10.3390/bios8040096] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Revised: 10/05/2018] [Accepted: 10/13/2018] [Indexed: 01/02/2023]
Abstract
A human mission to Mars can be viewed as the apex of human technological achievement. However, to make this dream a reality several obstacles need to be overcome. One is devising practical ways to safeguard the crew health during the mission through the development of easy operable and compact sensors. Lately, several smartphone-based sensing devices (SBDs) with the purpose to enable the immediate sensitive detection of chemicals, proteins or pathogens in remote settings have emerged. In this critical review, the potential to piggyback these systems for in situ analysis in space has been investigated on application of a systematic keyword search whereby the most relevant articles were examined comprehensively and existing SBDs were divided into 4 relevant groups for the monitoring of crew health during space missions. Recently developed recognition elements (REs), which could offer the enhanced ability to tolerate those harsh conditions in space, have been reviewed with recommendations offered. In addition, the potential use of cell free synthetic biology to obtain long-term shelf-stable reagents was reviewed. Finally, a synopsis of the possibilities of combining novel SBD, RE and nanomaterials to create a compact sensor-platform ensuring adequate crew health monitoring has been provided.
Collapse
|
23
|
Li Z, Askim JR, Suslick KS. The Optoelectronic Nose: Colorimetric and Fluorometric Sensor Arrays. Chem Rev 2018; 119:231-292. [DOI: 10.1021/acs.chemrev.8b00226] [Citation(s) in RCA: 476] [Impact Index Per Article: 68.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Zheng Li
- Department of Chemistry, University of Illinois at Urbana−Champaign, Urbana, Illinois 61801, United States
| | - Jon R. Askim
- National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Kenneth S. Suslick
- Department of Chemistry, University of Illinois at Urbana−Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|
24
|
Ross GMS, Bremer MGEG, Nielen MWF. Consumer-friendly food allergen detection: moving towards smartphone-based immunoassays. Anal Bioanal Chem 2018; 410:5353-5371. [PMID: 29582120 PMCID: PMC6096701 DOI: 10.1007/s00216-018-0989-7] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 02/14/2018] [Accepted: 02/26/2018] [Indexed: 12/28/2022]
Abstract
In this critical review, we provide a comprehensive overview of immunochemical food allergen assays and detectors in the context of their user-friendliness, through their connection to smartphones. Smartphone-based analysis is centered around citizen science, putting analysis into the hands of the consumer. Food allergies represent a significant worldwide health concern and consumers should be able to analyze their foods, whenever and wherever they are, for allergen presence. Owing to the need for a scientific background, traditional laboratory-based detection methods are generally unsuitable for the consumer. Therefore, it is important to develop simple, safe, and rapid assays that can be linked with smartphones as detectors to improve user accessibility. Smartphones make excellent detection systems because of their cameras, embedded flash functions, portability, connectivity, and affordability. Therefore, this review has summarized traditional laboratory-based methods for food allergen detection such as enzyme-linked-immunosorbent assay, flow cytometry, and surface plasmon resonance, and the potential to modernize these methods by interfacing them with a smartphone readout system, based on the aforementioned smartphone characteristics. This is the first review focusing on smartphone-based food-allergen detection methods designed with the intention of being consumer-friendly. Graphical abstract A smartphone-based food allergen detection system in three easy steps (1) sample preparation, (2) allergen detection on a smartphone using antibodies, which then transmits the data wirelessly, (3) analytical results sent straight to smartphone.
Collapse
Affiliation(s)
- Georgina M S Ross
- RIKILT, Wageningen University and Research, P.O Box 230, 6700 AE, Wageningen, The Netherlands.
| | - Monique G E G Bremer
- RIKILT, Wageningen University and Research, P.O Box 230, 6700 AE, Wageningen, The Netherlands
| | - Michel W F Nielen
- RIKILT, Wageningen University and Research, P.O Box 230, 6700 AE, Wageningen, The Netherlands
- Laboratory of Organic Chemistry, Wageningen University, Helix Building 124, Stippeng 4, 6708 WE, Wageningen, The Netherlands
| |
Collapse
|
25
|
Motalebizadeh A, Bagheri H, Asiaei S, Fekrat N, Afkhami A. New portable smartphone-based PDMS microfluidic kit for the simultaneous colorimetric detection of arsenic and mercury. RSC Adv 2018; 8:27091-27100. [PMID: 35540017 PMCID: PMC9083246 DOI: 10.1039/c8ra04006k] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Accepted: 07/17/2018] [Indexed: 01/04/2023] Open
Abstract
A smartphone-based microfluidic platform was developed for point-of-care (POC) detection using surface plasmon resonance (SPR) of gold nanoparticles (GNPs). The simultaneous colorimetric detection of trace arsenic and mercury ions (As3+ and Hg2+) was performed using a new image processing application (app). To achieve this goal, a microfluidic kit was fabricated using a polydimethylsiloxane (PDMS) substrate with the configuration of two separated sensing regions for the quantitative measurement of the color changes in GNPs to blue/gray. To fabricate the microfluidic kit, a Plexiglas mold was cut using a laser based on the model obtained from AutoCAD and Comsol outputs. The colorimetric signals originated from the formation of nanoparticle aggregates through the interaction of GNPs with dithiothreitol - 10,12-pentacosadiynoic acid (DTT-PCDA) and lysine (Lys) in the presence of As3+ and Hg2+ ions. This assembly exhibited the advantages of simplicity, low cost, and high portability along with a low volume of reagents and multiplex detection. Heavy Metals Detector (HMD), as a new app for the RGB reader, was programmed for an Android smartphone to quantify colorimetric analyses. Compared with traditional image processing, this app provided significant improvements in sensitivity, time of analysis, and simplicity because the color intensity is measured through a new normalization equation by converting RGB to an Integer system. As a simple, real-time, and portable analytical kit, the fabricated sensor could detect low concentrations of As3+ (710 to 1278 μg L-1) and Hg2+ (10.77 to 53.86 μg L-1) ions in water samples at ambient conditions.
Collapse
Affiliation(s)
- Abbas Motalebizadeh
- School of Mechanical Engineering, Iran University of Science and Technology Tehran Iran 1684613114
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences Tehran Iran +98 2182482000 +98 2182482000
| | - Sasan Asiaei
- School of Mechanical Engineering, Iran University of Science and Technology Tehran Iran 1684613114
| | - Nasim Fekrat
- Department of Computer, Science and Research Branch, Islamic Azad University Tehran Iran
| | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University Hamedan Iran
| |
Collapse
|
26
|
Abstract
Meeting policy requirements is essential for advancing molecular diagnostic devices from the laboratory to real-world applications and commercialization. Considering policy as a starting point in the design of new technology is a winning strategy. Rapid developments have put mobile biosensors at the frontier of molecular diagnostics, at times outpacing policymakers, and therefore offering new opportunities for breakthroughs in global health. In this Perspective we survey influential global health policies and recent developments in mobile biosensing in order to gain a new perspective for the future of the field. We summarize the main requirements for mobile diagnostics outlined by policy makers such as the World Health Organization (WHO), the World Bank, the European Union (EU), and the Food and Drug Administration (FDA). We then classify current mobile diagnostic technologies according to the manner in which the biosensor interfaces with a smartphone. We observe a trend in reducing hardware components and substituting instruments and laborious data processing steps for user-friendly apps. From this perspective we see software application developers as key collaborators for bridging the gap between policy and practice.
Collapse
Affiliation(s)
- Steven M. Russell
- Department of Chemistry, University of the Balearic Islands, 07122 Palma de Mallorca, Illes Balears, Spain
| | - Roberto de la Rica
- Department of Chemistry, University of the Balearic Islands, 07122 Palma de Mallorca, Illes Balears, Spain
| |
Collapse
|
27
|
van Rosmalen M, Ni Y, Vervoort DFM, Arts R, Ludwig SKJ, Merkx M. Dual-Color Bioluminescent Sensor Proteins for Therapeutic Drug Monitoring of Antitumor Antibodies. Anal Chem 2018; 90:3592-3599. [PMID: 29443503 PMCID: PMC5843950 DOI: 10.1021/acs.analchem.8b00041] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Monitoring the levels of therapeutic antibodies in individual patients would allow patient-specific dose optimization, with the potential for major therapeutic and financial benefits. Our group recently developed a new platform of bioluminescent sensor proteins (LUMABS; LUMinescent AntiBody Sensor) that allow antibody detection directly in blood plasma. In this study, we targeted four clinically important therapeutic antibodies, the Her2-receptor targeting trastuzumab, the anti-CD20 antibodies rituximab and obinutuzumab, and the EGFR-blocking cetuximab. A strong correlation was found between the affinity of the antibody binding peptide and sensor performance. LUMABS sensors with physiologically relevant affinities and decent sensor responses were obtained for trastuzumab and cetuximab using mimotope and meditope peptides, respectively, with affinities in the 10-7 M range. The lower affinity of the CD20-derived cyclic peptide employed in the anti-CD20 LUMABS sensor ( Kd = 10-5 M), translated in a LUMABS sensor with a strongly attenuated sensor response. The trastuzumab and cetuximab sensors were further characterized with respect to binding kinetics and their performance in undiluted blood plasma. For both antibodies, LUMABS-based detection directly in plasma compared well to the analytical performance of commercial ELISA kits. Besides identifying important design parameters for the development of new LUMABS sensors, this work demonstrates the potential of the LUMABS platform for point-of-care detection of therapeutic antibodies.
Collapse
Affiliation(s)
- Martijn van Rosmalen
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Yan Ni
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Daan F M Vervoort
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Remco Arts
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Susann K J Ludwig
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Maarten Merkx
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| |
Collapse
|
28
|
Austerjost J, Marquard D, Raddatz L, Geier D, Becker T, Scheper T, Lindner P, Beutel S. A smart device application for the automated determination of E. coli colonies on agar plates. Eng Life Sci 2017; 17:959-966. [PMID: 32624845 DOI: 10.1002/elsc.201700056] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 06/04/2017] [Accepted: 07/14/2017] [Indexed: 12/15/2022] Open
Abstract
The manual counting of colonies on agar plates to estimate the number of viable organisms (so-called colony-forming units-CFUs) in a defined sample is a commonly used method in microbiological laboratories. The automation of this arduous and time-consuming process through benchtop devices with integrated image processing capability addresses the need for faster and higher sample throughput and more accuracy. While benchtop colony counter solutions are often bulky and expensive, we investigated a cost-effective way to automate the colony counting process with smart devices using their inbuilt camera features and a server-based image processing algorithm. The performance of the developed solution is compared to a commercially available smartphone colony counter app and the manual counts of two scientists trained in biological experiments. The comparisons show a high accuracy of the presented system and demonstrate the potential of smart devices to displace well-established laboratory equipment.
Collapse
Affiliation(s)
- Jonas Austerjost
- Institute of Technical Chemistry Leibniz University Hannover Hannover Germany.,Institute of Brewing and Beverage Technology, Forschungszentrum Weihenstephan Technische Universität München Munich Germany
| | - Daniel Marquard
- Institute of Technical Chemistry Leibniz University Hannover Hannover Germany
| | - Lukas Raddatz
- Institute of Technical Chemistry Leibniz University Hannover Hannover Germany.,Institute of Brewing and Beverage Technology, Forschungszentrum Weihenstephan Technische Universität München Munich Germany
| | - Dominik Geier
- Institute of Brewing and Beverage Technology, Forschungszentrum Weihenstephan Technische Universität München Munich Germany
| | - Thomas Becker
- Institute of Brewing and Beverage Technology, Forschungszentrum Weihenstephan Technische Universität München Munich Germany
| | - Thomas Scheper
- Institute of Technical Chemistry Leibniz University Hannover Hannover Germany
| | - Patrick Lindner
- Institute of Technical Chemistry Leibniz University Hannover Hannover Germany
| | - Sascha Beutel
- Institute of Technical Chemistry Leibniz University Hannover Hannover Germany
| |
Collapse
|
29
|
Chan HN, Tan MJA, Wu H. Point-of-care testing: applications of 3D printing. LAB ON A CHIP 2017; 17:2713-2739. [PMID: 28702608 DOI: 10.1039/c7lc00397h] [Citation(s) in RCA: 96] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Point-of-care testing (POCT) devices fulfil a critical need in the modern healthcare ecosystem, enabling the decentralized delivery of imperative clinical strategies in both developed and developing worlds. To achieve diagnostic utility and clinical impact, POCT technologies are immensely dependent on effective translation from academic laboratories out to real-world deployment. However, the current research and development pipeline is highly bottlenecked owing to multiple restraints in material, cost, and complexity of conventionally available fabrication techniques. Recently, 3D printing technology has emerged as a revolutionary, industry-compatible method enabling cost-effective, facile, and rapid manufacturing of objects. This has allowed iterative design-build-test cycles of various things, from microfluidic chips to smartphone interfaces, that are geared towards point-of-care applications. In this review, we focus on highlighting recent works that exploit 3D printing in developing POCT devices, underscoring its utility in all analytical steps. Moreover, we also discuss key advantages of adopting 3D printing in the device development pipeline and identify promising opportunities in 3D printing technology that can benefit global health applications.
Collapse
Affiliation(s)
- Ho Nam Chan
- Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China.
| | | | | |
Collapse
|
30
|
Meyer Z, Höflich C, Wirthgen E, Olm S, Hammon HM, Hoeflich A. Analysis of the IGF-system in milk from farm animals - Occurrence, regulation, and biomarker potential. Growth Horm IGF Res 2017; 35:1-7. [PMID: 28544872 DOI: 10.1016/j.ghir.2017.05.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 05/04/2017] [Accepted: 05/09/2017] [Indexed: 12/18/2022]
Abstract
IGFs and IGF-binding proteins (IGFBPs) are abundantly present in milk and in dairy products. Compared to the IGFs, the IGFBP have received less attention in milk, although truncated IGFBPs and IGFBP-glycosylation have been described in milk. Thereby, complex control of local IGF-effects can be assumed on the levels of IGFBPs, proteases, and protease inhibitors. The present review collects the current knowledge both on presence and regulation of IGFs and IGFBPs in milk particularly from dairy animal species. As a rule higher levels of IGF-I, IGF-II, and IGFBPs are measured around parturition if compared to later time-points of lactation. In all farm animal species included in this review, it is found that the relative abundancies of IGFBPs in milk and serum are similar, with IGFBP-3 and -2 characterized by higher concentrations if compared to IGFBP-4 or -5. The concentrations of IGFs and IGFBPs in milk or dairy products can be altered by hormones, dairy processing, or fermentation. Because milk can be used for non-invasive biomarker research, quality management, and health monitoring, we discuss novel directions of IGF-analysis and potential on-site biomarker research in milk.
Collapse
Affiliation(s)
- Zianka Meyer
- Institute of Genome Biology, Leibniz-Institute for Farm Animal Biology (FBN), Dummerstorf, Germany
| | | | - Elisa Wirthgen
- Institute of Genome Biology, Leibniz-Institute for Farm Animal Biology (FBN), Dummerstorf, Germany; Ligandis GbR, Gülzow-Prüzen, Germany
| | - Sven Olm
- MQD M-V mbH, Institut für Analytik und Hygiene, Güstrow, Germany
| | - Harald M Hammon
- Institute of Nutritional Physiology "Oskar Kellner", Leibniz-Institute for Farm Animal Biology (FBN), Dummerstorf, Germany
| | - Andreas Hoeflich
- Institute of Genome Biology, Leibniz-Institute for Farm Animal Biology (FBN), Dummerstorf, Germany.
| |
Collapse
|
31
|
Regal P, Lamas A, Fente CA, Franco CM, Cepeda A. Tracing (r)bST in cattle: Liquid-based options for extraction and separation. J LIQ CHROMATOGR R T 2017. [DOI: 10.1080/10826076.2017.1331453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- Patricia Regal
- Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Veterinary Science, Universidade de Santiago de Compostela, Lugo, Spain
| | - Alexandre Lamas
- Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Veterinary Science, Universidade de Santiago de Compostela, Lugo, Spain
| | - Cristina A. Fente
- Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Veterinary Science, Universidade de Santiago de Compostela, Lugo, Spain
| | - Carlos M. Franco
- Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Veterinary Science, Universidade de Santiago de Compostela, Lugo, Spain
| | - Alberto Cepeda
- Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Veterinary Science, Universidade de Santiago de Compostela, Lugo, Spain
| |
Collapse
|
32
|
Koydemir HC, Ozcan A. Mobile phones create new opportunities for microbiology research and clinical applications. Future Microbiol 2017; 12:641-644. [PMID: 28541094 DOI: 10.2217/fmb-2017-0046] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Affiliation(s)
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA.,Bioengineering Department, University of California, Los Angeles, CA 90095, USA.,California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| |
Collapse
|
33
|
Pohanka M. Small camera as a handheld colorimetric tool in the analytical chemistry. CHEMICAL PAPERS 2017. [DOI: 10.1007/s11696-017-0166-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
34
|
Li Z, Li Z, Zhao D, Wen F, Jiang J, Xu D. Smartphone-based visualized microarray detection for multiplexed harmful substances in milk. Biosens Bioelectron 2017; 87:874-880. [DOI: 10.1016/j.bios.2016.09.046] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 09/04/2016] [Accepted: 09/13/2016] [Indexed: 11/24/2022]
|
35
|
Feng S, Tseng D, Di Carlo D, Garner OB, Ozcan A. High-throughput and automated diagnosis of antimicrobial resistance using a cost-effective cellphone-based micro-plate reader. Sci Rep 2016; 6:39203. [PMID: 27976700 PMCID: PMC5156953 DOI: 10.1038/srep39203] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Accepted: 11/16/2016] [Indexed: 11/18/2022] Open
Abstract
Routine antimicrobial susceptibility testing (AST) can prevent deaths due to bacteria and reduce the spread of multi-drug-resistance, but cannot be regularly performed in resource-limited-settings due to technological challenges, high-costs, and lack of trained professionals. We demonstrate an automated and cost-effective cellphone-based 96-well microtiter-plate (MTP) reader, capable of performing AST without the need for trained diagnosticians. Our system includes a 3D-printed smartphone attachment that holds and illuminates the MTP using a light-emitting-diode array. An inexpensive optical fiber-array enables the capture of the transmitted light of each well through the smartphone camera. A custom-designed application sends the captured image to a server to automatically determine well-turbidity, with results returned to the smartphone in ~1 minute. We tested this mobile-reader using MTPs prepared with 17 antibiotics targeting Gram-negative bacteria on clinical isolates of Klebsiella pneumoniae, containing highly-resistant antimicrobial profiles. Using 78 patient isolate test-plates, we demonstrated that our mobile-reader meets the FDA-defined AST criteria, with a well-turbidity detection accuracy of 98.21%, minimum-inhibitory-concentration accuracy of 95.12%, and a drug-susceptibility interpretation accuracy of 99.23%, with no very major errors. This mobile-reader could eliminate the need for trained diagnosticians to perform AST, reduce the cost-barrier for routine testing, and assist in spatio-temporal tracking of bacterial resistance.
Collapse
Affiliation(s)
- Steve Feng
- Electrical Engineering Department, University of California, Los Angeles, California 90095, United States.,Bioengineering Department, University of California, Los Angeles, California 90095, United States
| | - Derek Tseng
- Electrical Engineering Department, University of California, Los Angeles, California 90095, United States.,Bioengineering Department, University of California, Los Angeles, California 90095, United States
| | - Dino Di Carlo
- Bioengineering Department, University of California, Los Angeles, California 90095, United States.,California NanoSystems Institute, University of California, Los Angeles, California 90095, United States.,Jonsson Comprehensive Cancer Center, University of California, Los Angeles, California 90095, United States
| | - Omai B Garner
- Department of Pathology and Laboratory Medicine, David Geffen School of Medicine, University of California, Los Angeles, California 90095, United States
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, California 90095, United States.,Bioengineering Department, University of California, Los Angeles, California 90095, United States.,California NanoSystems Institute, University of California, Los Angeles, California 90095, United States.,Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, California 90095 United States
| |
Collapse
|
36
|
Zhang Y, Ge S, Yu J. Chemical and biochemical analysis on lab-on-a-chip devices fabricated using three-dimensional printing. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.09.008] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
37
|
Sun AC, Yao C, Venkatesh AG, Hall DA. An Efficient Power Harvesting Mobile Phone-Based Electrochemical Biosensor for Point-of-Care Health Monitoring. SENSORS AND ACTUATORS. B, CHEMICAL 2016; 235:126-135. [PMID: 27725788 PMCID: PMC5055131 DOI: 10.1016/j.snb.2016.05.010] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Cellular phone penetration has grown continually over the past two decades with the number of connected devices rapidly approaching the total world population. Leveraging the worldwide ubiquity and connectivity of these devices, we developed a mobile phone-based electrochemical biosensor platform for point-of-care (POC) diagnostics and wellness tracking. The platform consists of an inexpensive electronic module (< $20) containing a low-power potentiostat that interfaces with and efficiently harvests power from a wide variety of phones through the audio jack. Active impedance matching improves the harvesting efficiency to 79%. Excluding loses from supply rectification and regulation, the module consumes 6.9 mW peak power and can measure < 1 nA bidirectional current. The prototype was shown to operate within the available power budget set by mobile devices and produce data that matches well with that of an expensive laboratory grade instrument. We demonstrate that the platform can be used to track the concentration of secretory leukocyte protease inhibitor (SLPI), a biomarker for monitoring lung infections in cystic fibrosis patients, in its physiological range via an electrochemical sandwich assay on disposable screen-printed electrodes with a 1 nM limit of detection.
Collapse
Affiliation(s)
- Alexander C. Sun
- Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
| | - Chengyang Yao
- Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
| | - A. G. Venkatesh
- Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
| | - Drew A. Hall
- Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
| |
Collapse
|
38
|
Sun A, Venkatesh AG, Hall DA. A Multi-Technique Reconfigurable Electrochemical Biosensor: Enabling Personal Health Monitoring in Mobile Devices. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:945-954. [PMID: 28113176 DOI: 10.1109/tbcas.2016.2586504] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper describes the design and characterization of a reconfigurable, multi-technique electrochemical biosensor designed for direct integration into smartphone and wearable technologies to enable remote and accurate personal health monitoring. By repurposing components from one mode to the next, the biosensor's potentiostat is able reconfigure itself into three different measurements modes to perform amperometric, potentiometric, and impedance spectroscopic tests all with minimal redundant devices. A [Formula: see text] PCB prototype of the module was developed with discrete components and tested using Google's Project Ara modular smartphone. The amperometric mode has a ±1 nA to [Formula: see text] measurement range. When used to detect pH, the potentiometric mode achieves a resolution of < 0.08 pH units. In impedance measurement mode, the device can measure 50 Ω-10 [Formula: see text] and has been shown to have of phase error. This prototype was used to perform several point-of-care health tracking assays suitable for use with mobile devices: 1) Blood glucose tests were conducted and shown to cover the diagnostic range for Diabetic patients ( ∼ 200 mg/dL). 2) Lactoferrin, a biomarker for urinary tract infections, was detected with a limit of detection of approximately 1 ng/mL. 3) pH tests of sweat were conducted to track dehydration during exercise. 4) EIS was used to determine the concentration of NeutrAvidin via a label-free assay.
Collapse
|
39
|
Yang H, Rahman T, Du D, Panat R, Lin Y. 3-D Printed Adjustable Microelectrode Arrays for Electrochemical Sensing and Biosensing. SENSORS AND ACTUATORS. B, CHEMICAL 2016; 230:600-606. [PMID: 27019550 PMCID: PMC4802967 DOI: 10.1016/j.snb.2016.02.113] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Printed Electronics has emerged as an important fabrication technique that overcomes several shortcomings of conventional lithography and provides custom rapid prototyping for various sensor applications. In this work, silver microelectrode arrays (MEA) with three different electrode spacing were fabricated using 3-D printing by the aerosol jet technology. The microelectrodes were printed at a length scale of about 15 μm, with the space between the electrodes accurately controlled to about 2 times (30 μm, MEA30), 6.6 times (100 μm, MEA100) and 12 times (180 μm, MEA180) the trace width, respectively. Hydrogen peroxide and glucose were chosen as model analytes to demonstrate the performance of the MEA for sensor applications. The electrodes are shown to reduce hydrogen peroxide with a reduction current proportional to the concentration of hydrogen peroxide for certain concentration ranges. Further, the sensitivity of the current for the three electrode configurations was shown to decrease with an increase in the microelectrode spacing (sensitivity of MEA30: MEA100: MEA180 was in the ratio of 3.7: 2.8: 1), demonstrating optimal MEA geometry for such applications. The noise of the different electrode configurations is also characterized and shows a dramatic reduction from MEA30 to MEA100 and MEA180 electrodes. Further, it is shown that the response current is proportional to MEA100 and MEA180 electrode areas, but not for the area of MEA30 electrode (the current density of MEA30 : MEA100 : MEA180 is 0.25 : 1 : 1), indicating that the MEA30 electrodes suffer from diffusion overlap from neighboring electrodes. The work thus establishes the lower limit of microelectrode spacing for our geometry. The lowest detection limit of the MEAs was calculated (with S/N = 3) to be 0.45 μM. Glucose oxidase was immobilized on MEA100 microelectrodes to demonstrate a glucose biosensor application. The sensitivity of glucose biosensor was 1.73 μAmM-1 and the calculated value of detection limit (S/N = 3) was 1.7 μM. The electrochemical response characteristics of the MEAs were in agreement with the predictions of existing models. The current work opens up the possibility of additive manufacturing as a fabrication technique for low cost custom-shaped MEA structures that can be used as electrochemical platforms for a wide range of sensor applications.
Collapse
Affiliation(s)
- Haipeng Yang
- School of Mechanical and Material Engineering, Washington State University, Pullman, WA 99164, United States
- College of Materials Science and Engineering, Nanshan District Key Lab for Biopolymers and Safety Evaluation, and Shenzhen Key Laboratory of Special Functional Materials, Shenzhen University, Shenzhen 518060, P.R. China
| | - Taibur Rahman
- School of Mechanical and Material Engineering, Washington State University, Pullman, WA 99164, United States
| | - Dan Du
- School of Mechanical and Material Engineering, Washington State University, Pullman, WA 99164, United States
- Corresponding author Tel: +1 509 335 8523, ; Tel: +1 509 335 9814,
| | - Rahul Panat
- School of Mechanical and Material Engineering, Washington State University, Pullman, WA 99164, United States
- Corresponding author Tel: +1 509 335 8523, ; Tel: +1 509 335 9814,
| | - Yuehe Lin
- School of Mechanical and Material Engineering, Washington State University, Pullman, WA 99164, United States
- Corresponding author Tel: +1 509 335 8523, ; Tel: +1 509 335 9814,
| |
Collapse
|
40
|
Mzava O, Taş Z, İçöz K. Magnetic micro/nanoparticle flocculation-based signal amplification for biosensing. Int J Nanomedicine 2016; 11:2619-31. [PMID: 27354793 PMCID: PMC4907731 DOI: 10.2147/ijn.s108692] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
We report a time and cost efficient signal amplification method for biosensors employing magnetic particles. In this method, magnetic particles in an applied external magnetic field form magnetic dipoles, interact with each other, and accumulate along the magnetic field lines. This magnetic interaction does not need any biomolecular coating for binding and can be controlled with the strength of the applied magnetic field. The accumulation can be used to amplify the corresponding pixel area that is obtained from an image of a single magnetic particle. An application of the method to the Escherichia coli 0157:H7 bacteria samples is demonstrated in order to show the potential of the approach. A minimum of threefold to a maximum of 60-fold amplification is reached from a single bacteria cell under a magnetic field of 20 mT.
Collapse
Affiliation(s)
- Omary Mzava
- BioMINDS (Bio Micro/Nano Devices and Sensors) Laboratory, Department of Electrical and Electronics Engineering, Abdullah Gül University, Kayseri, Turkey
| | - Zehra Taş
- BioMINDS (Bio Micro/Nano Devices and Sensors) Laboratory, Department of Electrical and Electronics Engineering, Abdullah Gül University, Kayseri, Turkey
| | - Kutay İçöz
- BioMINDS (Bio Micro/Nano Devices and Sensors) Laboratory, Department of Electrical and Electronics Engineering, Abdullah Gül University, Kayseri, Turkey; Bioengineering Department, Abdullah Gül University, Kayseri, Turkey
| |
Collapse
|
41
|
Serum responsiveness to recombinant bovine somatotropin in buffalo: a three-month lactation study using an acid-stripping ELISA for screening. Drug Test Anal 2016; 9:646-656. [DOI: 10.1002/dta.1994] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2016] [Revised: 03/26/2016] [Accepted: 04/12/2016] [Indexed: 11/07/2022]
|
42
|
McCracken KE, Angus SV, Reynolds KA, Yoon JY. Multimodal Imaging and Lighting Bias Correction for Improved μPAD-based Water Quality Monitoring via Smartphones. Sci Rep 2016; 6:27529. [PMID: 27283336 PMCID: PMC4901345 DOI: 10.1038/srep27529] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2016] [Accepted: 05/16/2016] [Indexed: 01/06/2023] Open
Abstract
Smartphone image-based sensing of microfluidic paper analytical devices (μPADs) offers low-cost and mobile evaluation of water quality. However, consistent quantification is a challenge due to variable environmental, paper, and lighting conditions, especially across large multi-target μPADs. Compensations must be made for variations between images to achieve reproducible results without a separate lighting enclosure. We thus developed a simple method using triple-reference point normalization and a fast-Fourier transform (FFT)-based pre-processing scheme to quantify consistent reflected light intensity signals under variable lighting and channel conditions. This technique was evaluated using various light sources, lighting angles, imaging backgrounds, and imaging heights. Further testing evaluated its handle of absorbance, quenching, and relative scattering intensity measurements from assays detecting four water contaminants – Cr(VI), total chlorine, caffeine, and E. coli K12 – at similar wavelengths using the green channel of RGB images. Between assays, this algorithm reduced error from μPAD surface inconsistencies and cross-image lighting gradients. Although the algorithm could not completely remove the anomalies arising from point shadows within channels or some non-uniform background reflections, it still afforded order-of-magnitude quantification and stable assay specificity under these conditions, offering one route toward improving smartphone quantification of μPAD assays for in-field water quality monitoring.
Collapse
Affiliation(s)
- Katherine E McCracken
- Department of Agricultural &Biosystems Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Scott V Angus
- Department of Agricultural &Biosystems Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kelly A Reynolds
- Mel and Enid Zuckerman College of Public Health, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jeong-Yeol Yoon
- Department of Agricultural &Biosystems Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
43
|
Rasooly R, Bruck HA, Balsam J, Prickril B, Ossandon M, Rasooly A. Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health. Diagnostics (Basel) 2016; 6:E19. [PMID: 27196933 PMCID: PMC4931414 DOI: 10.3390/diagnostics6020019] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 04/19/2016] [Accepted: 05/06/2016] [Indexed: 12/20/2022] Open
Abstract
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings.
Collapse
Affiliation(s)
- Reuven Rasooly
- Western Regional Research Center, Agricultural Research Service, U.S. Department of Agriculture, Albany, CA 94706, USA.
| | - Hugh Alan Bruck
- Department of Mechanical Engineering, University of Maryland College Park (UMCP), College Park, MD 20742, USA.
| | - Joshua Balsam
- Division of Chemistry and Toxicology Devices, Office of In Vitro Diagnostics and Radiological Health, FDA, Silver Spring, MD 20993, USA.
| | - Ben Prickril
- National Cancer Institute, Rockville, MD 208503, USA.
| | | | | |
Collapse
|
44
|
Cummins BM, Ligler FS, Walker GM. Point-of-care diagnostics for niche applications. Biotechnol Adv 2016; 34:161-76. [PMID: 26837054 PMCID: PMC4833668 DOI: 10.1016/j.biotechadv.2016.01.005] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 01/28/2016] [Accepted: 01/28/2016] [Indexed: 01/26/2023]
Abstract
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted.
Collapse
Affiliation(s)
- Brian M Cummins
- Joint Department of Biomedical Engineering, University of North Carolina - Chapel Hill and North Carolina State University, Raleigh, NC, 27695, USA
| | - Frances S Ligler
- Joint Department of Biomedical Engineering, University of North Carolina - Chapel Hill and North Carolina State University, Raleigh, NC, 27695, USA
| | - Glenn M Walker
- Joint Department of Biomedical Engineering, University of North Carolina - Chapel Hill and North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
45
|
Nanoscale Extracellular Vesicle Analysis in Alzheimer's Disease Diagnosis and Therapy. Int J Alzheimers Dis 2016; 2016:8053139. [PMID: 27213078 PMCID: PMC4861781 DOI: 10.1155/2016/8053139] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Accepted: 03/24/2016] [Indexed: 12/21/2022] Open
Abstract
Diagnostic assays that leverage bloodborne neuron-derived (neuronal) nanoscale extracellular vesicles (nsEVs) as “windows into the brain” can predict incidence of Alzheimer's Disease (AD) many years prior to onset. Beyond diagnostics, bloodborne neuronal nsEVs analysis may have substantial translational impact by revealing mechanisms of AD pathology; such knowledge could enlighten new drug targets and lead to new therapeutic approaches. The potential to establish three-dimensional nsEV analysis methods that characterize highly purified bloodborne nsEV populations in method of enrichment, cell type origin, and protein or RNA abundance dimensions could bring this promise to bear by yielding nsEV “omics” datasets that uncover new AD biomarkers and enable AD therapeutic development. In this review we provide a survey of both the current status of and new developments on the horizon in the field of neuronal nsEV analysis. This survey is supplemented by a discussion of the potential to translate such neuronal nsEV analyses to AD clinical diagnostic applications and drug development.
Collapse
|
46
|
Arts R, den Hartog I, Zijlema SE, Thijssen V, van der Beelen SHE, Merkx M. Detection of Antibodies in Blood Plasma Using Bioluminescent Sensor Proteins and a Smartphone. Anal Chem 2016; 88:4525-32. [PMID: 27018236 DOI: 10.1021/acs.analchem.6b00534] [Citation(s) in RCA: 105] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Antibody detection is of fundamental importance in many diagnostic and bioanalytical assays, yet current detection techniques tend to be laborious and/or expensive. We present a new sensor platform (LUMABS) based on bioluminescence resonance energy transfer (BRET) that allows detection of antibodies directly in solution using a smartphone as the sole piece of equipment. LUMABS are single-protein sensors that consist of the blue-light emitting luciferase NanoLuc connected via a semiflexible linker to the green fluorescent acceptor protein mNeonGreen, which are kept close together using helper domains. Binding of an antibody to epitope sequences flanking the linker disrupts the interaction between the helper domains, resulting in a large decrease in BRET efficiency. The resulting change in color of the emitted light from green-blue to blue can be detected directly in blood plasma, even at picomolar concentrations of antibody. Moreover, the modular architecture of LUMABS allows changing of target specificity by simple exchange of epitope sequences, as demonstrated here for antibodies against HIV1-p17, hemagglutinin (HA), and dengue virus type I. The combination of sensitive ratiometric bioluminescent detection and the intrinsic modularity of the LUMABS design provides an attractive generic platform for point-of-care antibody detection that avoids the complex liquid handling steps associated with conventional immunoassays.
Collapse
Affiliation(s)
- Remco Arts
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Ilona den Hartog
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Stefan E Zijlema
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Vito Thijssen
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Stan H E van der Beelen
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Maarten Merkx
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
47
|
Finetti C, Plavisch L, Chiari M. Use of quantum dots as mass and fluorescence labels in microarray biosensing. Talanta 2015; 147:397-401. [PMID: 26592624 DOI: 10.1016/j.talanta.2015.10.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Revised: 09/30/2015] [Accepted: 10/04/2015] [Indexed: 02/07/2023]
Abstract
In this work, we demonstrate the efficacy of a Quantum Dot (QD) mass label strategy to enhance sensitivity in an interferometric technique called interferometric reflectance imaging sensor (IRIS). This biomass detection platform confers the advantage of absolute mass quantification and lower cost, easily implementable equipment. We discuss the advantages of this label when used in parallel with fluorescence detection. QDs represent a unique opportunity to improve sensitivity in both mass-label detection methods due to their large detectable mass, as well as in fluorescence detection, as they fluoresce without quenching. Streptavidin-conjugated QDs (SA-QDs) have been investigated as such a dual-role probe because of their large shape and mass, their 655nm emission peak for fluorescent detection platforms, and their robust insensitivity to photobleaching and quenching. In particular we explored their dual role in a microarrays immunoassay designed to detect antibodies against β-lactoglobulin, a common milk allergen. The SA-QDs formed a large detectable monolayer of 6.2ng/mm(2) in the saturation conditions, a mass signal corroborated by previous studies by Platt et al..
Collapse
Affiliation(s)
- Chiara Finetti
- Consiglio Nazionale delle Ricerche, Istituto di Chimica del Riconoscimento Molecolare, 20131 Milano, Italy
| | - Lauren Plavisch
- Consiglio Nazionale delle Ricerche, Istituto di Chimica del Riconoscimento Molecolare, 20131 Milano, Italy
| | - Marcella Chiari
- Consiglio Nazionale delle Ricerche, Istituto di Chimica del Riconoscimento Molecolare, 20131 Milano, Italy.
| |
Collapse
|