1
|
Ahmedt-Aristizabal D, Armin MA, Hayder Z, Garcia-Cairasco N, Petersson L, Fookes C, Denman S, McGonigal A. Deep learning approaches for seizure video analysis: A review. Epilepsy Behav 2024; 154:109735. [PMID: 38522192 DOI: 10.1016/j.yebeh.2024.109735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 02/06/2024] [Accepted: 03/03/2024] [Indexed: 03/26/2024]
Abstract
Seizure events can manifest as transient disruptions in the control of movements which may be organized in distinct behavioral sequences, accompanied or not by other observable features such as altered facial expressions. The analysis of these clinical signs, referred to as semiology, is subject to observer variations when specialists evaluate video-recorded events in the clinical setting. To enhance the accuracy and consistency of evaluations, computer-aided video analysis of seizures has emerged as a natural avenue. In the field of medical applications, deep learning and computer vision approaches have driven substantial advancements. Historically, these approaches have been used for disease detection, classification, and prediction using diagnostic data; however, there has been limited exploration of their application in evaluating video-based motion detection in the clinical epileptology setting. While vision-based technologies do not aim to replace clinical expertise, they can significantly contribute to medical decision-making and patient care by providing quantitative evidence and decision support. Behavior monitoring tools offer several advantages such as providing objective information, detecting challenging-to-observe events, reducing documentation efforts, and extending assessment capabilities to areas with limited expertise. The main applications of these could be (1) improved seizure detection methods; (2) refined semiology analysis for predicting seizure type and cerebral localization. In this paper, we detail the foundation technologies used in vision-based systems in the analysis of seizure videos, highlighting their success in semiology detection and analysis, focusing on work published in the last 7 years. We systematically present these methods and indicate how the adoption of deep learning for the analysis of video recordings of seizures could be approached. Additionally, we illustrate how existing technologies can be interconnected through an integrated system for video-based semiology analysis. Each module can be customized and improved by adapting more accurate and robust deep learning approaches as these evolve. Finally, we discuss challenges and research directions for future studies.
Collapse
Affiliation(s)
- David Ahmedt-Aristizabal
- Imaging and Computer Vision Group, CSIRO Data61, Australia; SAIVT Laboratory, Queensland University of Technology, Australia.
| | | | - Zeeshan Hayder
- Imaging and Computer Vision Group, CSIRO Data61, Australia.
| | - Norberto Garcia-Cairasco
- Physiology Department and Neuroscience and Behavioral Sciences Department, Ribeirão Preto Medical School, University of São Paulo, Brazil.
| | - Lars Petersson
- Imaging and Computer Vision Group, CSIRO Data61, Australia.
| | - Clinton Fookes
- SAIVT Laboratory, Queensland University of Technology, Australia.
| | - Simon Denman
- SAIVT Laboratory, Queensland University of Technology, Australia.
| | - Aileen McGonigal
- Neurosciences Centre, Mater Hospital, Australia; Queensland Brain Institute, The University of Queensland, Australia.
| |
Collapse
|
2
|
Brown BM, Boyne AMH, Hassan AM, Allam AK, Cotton RJ, Haneef Z. Computer vision for automated seizure detection and classification: A systematic review. Epilepsia 2024; 65:1176-1202. [PMID: 38426252 DOI: 10.1111/epi.17926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/08/2024] [Accepted: 02/09/2024] [Indexed: 03/02/2024]
Abstract
Computer vision (CV) shows increasing promise as an efficient, low-cost tool for video seizure detection and classification. Here, we provide an overview of the fundamental concepts needed to understand CV and summarize the structure and performance of various model architectures used in video seizure analysis. We conduct a systematic literature review of the PubMed, Embase, and Web of Science databases from January 1, 2000 to September 15, 2023, to identify the strengths and limitations of CV seizure analysis methods and discuss the utility of these models when applied to different clinical seizure phenotypes. Reviews, nonhuman studies, and those with insufficient or poor quality data are excluded from the review. Of the 1942 records identified, 45 meet inclusion criteria and are analyzed. We conclude that the field has shown tremendous growth over the past 2 decades, leading to several model architectures with impressive accuracy and efficiency. The rapid and scalable detection offered by CV models holds the potential to reduce sudden unexpected death in epilepsy and help alleviate resource limitations in epilepsy monitoring units. However, a lack of standardized, thorough validation measures and concerns about patient privacy remain important obstacles for widespread acceptance and adoption. Investigation into the performance of models across varied datasets from clinical and nonclinical environments is an essential area for further research.
Collapse
Affiliation(s)
- Brandon M Brown
- Department of Neurology, Baylor College of Medicine, Houston, Texas, USA
| | - Aidan M H Boyne
- Department of Neurology, Baylor College of Medicine, Houston, Texas, USA
| | - Adel M Hassan
- Department of Neurology, Baylor College of Medicine, Houston, Texas, USA
| | - Anthony K Allam
- Department of Neurology, Baylor College of Medicine, Houston, Texas, USA
| | - R James Cotton
- Shirley Ryan Ability Lab, Chicago, Illinois, USA
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, Illinois, USA
| | - Zulfi Haneef
- Department of Neurology, Baylor College of Medicine, Houston, Texas, USA
- Neurology Care Line, Michael E. DeBakey VA Medical Center, Houston, Texas, USA
| |
Collapse
|
3
|
Ho R, Carrazana EJ. The history of motion photography to video electroencephalography in the study of functional seizures and related seizure disorders: The first 100 years. Seizure 2023; 112:68-71. [PMID: 37769546 DOI: 10.1016/j.seizure.2023.09.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 08/29/2023] [Accepted: 09/23/2023] [Indexed: 10/03/2023] Open
Abstract
This historical note highlights pivotal events of technology progressing between the late 19th and the 20th century to capture functional seizures and other related seizure episodes. From Charcot's initial use of photography for his study of hysteria at the Salpêtrière to the development of cinematography by Muybridge and Marey to study motion to the initial use of video electroencephalography (vEEG) through a pairing of cinematography with EEG, and the advent of EEG telemetry to eventually the development of modern epilepsy monitoring unit through the adoption of cameras and an improved long-term monitoring vEEG system.
Collapse
Affiliation(s)
- Richard Ho
- University of Hawai`i, John A. Burns School of Medicine (JABSOM), USA; Hawaii Pacific Neuroscience, Honolulu, HI, USA
| | - Enrique J Carrazana
- University of Hawai`i, John A. Burns School of Medicine (JABSOM), USA; Hawaii Pacific Neuroscience, Honolulu, HI, USA; Neurelis, Inc. San Diego, California, USA.
| |
Collapse
|
4
|
Bigalke A, Hansen L, Diesel J, Hennigs C, Rostalski P, Heinrich MP. Anatomy-guided domain adaptation for 3D in-bed human pose estimation. Med Image Anal 2023; 89:102887. [PMID: 37453235 DOI: 10.1016/j.media.2023.102887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 06/16/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023]
Abstract
3D human pose estimation is a key component of clinical monitoring systems. The clinical applicability of deep pose estimation models, however, is limited by their poor generalization under domain shifts along with their need for sufficient labeled training data. As a remedy, we present a novel domain adaptation method, adapting a model from a labeled source to a shifted unlabeled target domain. Our method comprises two complementary adaptation strategies based on prior knowledge about human anatomy. First, we guide the learning process in the target domain by constraining predictions to the space of anatomically plausible poses. To this end, we embed the prior knowledge into an anatomical loss function that penalizes asymmetric limb lengths, implausible bone lengths, and implausible joint angles. Second, we propose to filter pseudo labels for self-training according to their anatomical plausibility and incorporate the concept into the Mean Teacher paradigm. We unify both strategies in a point cloud-based framework applicable to unsupervised and source-free domain adaptation. Evaluation is performed for in-bed pose estimation under two adaptation scenarios, using the public SLP dataset and a newly created dataset. Our method consistently outperforms various state-of-the-art domain adaptation methods, surpasses the baseline model by 31%/66%, and reduces the domain gap by 65%/82%. Source code is available at https://github.com/multimodallearning/da-3dhpe-anatomy.
Collapse
Affiliation(s)
- Alexander Bigalke
- Institute of Medical Informatics, University of Lübeck, Ratzeburger Allee 160, 23538 Lübeck, Germany.
| | - Lasse Hansen
- EchoScout GmbH, Maria-Goeppert-Str. 3, 23562 Lübeck, Germany
| | - Jasper Diesel
- Drägerwerk AG & Co. KGaA, Moislinger Allee 53-55, 23558 Lübeck, Germany
| | - Carlotta Hennigs
- Institute for Electrical Engineering in Medicine, University of Lübeck, Moislinger Allee 53-55, 23558 Lübeck, Germany
| | - Philipp Rostalski
- Institute for Electrical Engineering in Medicine, University of Lübeck, Moislinger Allee 53-55, 23558 Lübeck, Germany
| | - Mattias P Heinrich
- Institute of Medical Informatics, University of Lübeck, Ratzeburger Allee 160, 23538 Lübeck, Germany
| |
Collapse
|
5
|
Novel 3D video action recognition deep learning approach for near real time epileptic seizure classification. Sci Rep 2022; 12:19571. [PMID: 36379994 PMCID: PMC9666544 DOI: 10.1038/s41598-022-23133-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 10/25/2022] [Indexed: 11/16/2022] Open
Abstract
Seizure semiology is a well-established method to classify epileptic seizure types, but requires a significant amount of resources as long-term Video-EEG monitoring needs to be visually analyzed. Therefore, computer vision based diagnosis support tools are a promising approach. In this article, we utilize infrared (IR) and depth (3D) videos to show the feasibility of a 24/7 novel object and action recognition based deep learning (DL) monitoring system to differentiate between epileptic seizures in frontal lobe epilepsy (FLE), temporal lobe epilepsy (TLE) and non-epileptic events. Based on the largest 3Dvideo-EEG database in the world (115 seizures/+680,000 video-frames/427GB), we achieved a promising cross-subject validation f1-score of 0.833±0.061 for the 2 class (FLE vs. TLE) and 0.763 ± 0.083 for the 3 class (FLE vs. TLE vs. non-epileptic) case, from 2 s samples, with an automated semi-specialized depth (Acc.95.65%) and Mask R-CNN (Acc.96.52%) based cropping pipeline to pre-process the videos, enabling a near-real-time seizure type detection and classification tool. Our results demonstrate the feasibility of our novel DL approach to support 24/7 epilepsy monitoring, outperforming all previously published methods.
Collapse
|
6
|
Ojanen P, Zabihi M, Knight A, Roivainen R, Lamusuo S, Peltola J. Feasibility of video/audio monitoring in the analysis of motion and treatment effects on night-time seizures - Interventional study. Epilepsy Res 2022; 184:106949. [PMID: 35661573 DOI: 10.1016/j.eplepsyres.2022.106949] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 05/17/2022] [Accepted: 05/25/2022] [Indexed: 11/03/2022]
Abstract
THE AIM OF THE STUDY This pilot study assessed the ability of a video/audio-based seizure monitoring system to evaluate (I) baseline frequency and severity of nocturnal seizures with motor features in patients with drug-resistant epilepsy (DRE) and (II) the individual effect of brivaracetam (BRV) treatment on number, duration and movement intensity of these seizure types. Algorithmic feature analysis was developed for assessment of qualitative changes in movement intensity measurements within seizure types before and after BRV intervention. MATERIALS AND METHODS Night-time motor seizures of recruited patients were recorded in two separate four-week monitoring periods. The first period defined a prescreening phase (n = 13 patients) to establish a baseline, and the second period defined the intervention phase (n = 9 patients), with BRV initiated during the second week of the second monitoring period. All recorded nights were analyzed by an expert video reviewer, and all unequivocal seizures were classified by an epileptologist. Seizure frequencies using both seizure diaries and video monitoring were compared. The effect of BRV on both seizure duration and movement intensity was assessed by numerical comparison of visual features calculated from motion characteristics of the video, as well as spectral features from the recorded audio. The statistical significance of changes in seizure duration and intensity before and after the intervention were investigated by Wilcoxon rank-sum test and visual inspection of Kernel density estimation. RESULTS 8 patients marked seizures in their seizure diaries during the prescreening phase. During the three-week follow-up, three patients achieved > 50% seizure decrease, four patients did not respond to treatment, and two patients experienced worsening of seizures. Five patients were able to document 40-70% of their seizures compared to the video/audio monitoring system. According to the signal feature analysis the intervention decreased movement intensity with clear clinical significance in three patients, whereas statistically significant differences in features appeared in 8 out of 9 patients. CONCLUSIONS The novel video/audio monitoring system improved the evaluation of treatment effect compared to the seizure diaries and succeeded in providing a comparative intra-patient assessment of the movement intensity and duration of the recorded seizures.
Collapse
Affiliation(s)
- Petri Ojanen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
| | | | | | - Reina Roivainen
- Helsinki University Hospital, Neurocenter, Epilepsia Helsinki, Finland
| | - Salla Lamusuo
- Clinical Neurosciences, University of Turku and Neurocenter, Turku University Hospital, Finland
| | - Jukka Peltola
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland; Department of Neurology, Tampere University Hospital, Tampere, Finland
| |
Collapse
|
7
|
Scott B, Seyres M, Philp F, Chadwick EK, Blana D. Healthcare applications of single camera markerless motion capture: a scoping review. PeerJ 2022; 10:e13517. [PMID: 35642200 PMCID: PMC9148557 DOI: 10.7717/peerj.13517] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 05/09/2022] [Indexed: 01/17/2023] Open
Abstract
Background Single camera markerless motion capture has the potential to facilitate at home movement assessment due to the ease of setup, portability, and affordable cost of the technology. However, it is not clear what the current healthcare applications of single camera markerless motion capture are and what information is being collected that may be used to inform clinical decision making. This review aims to map the available literature to highlight potential use cases and identify the limitations of the technology for clinicians and researchers interested in the collection of movement data. Survey Methodology Studies were collected up to 14 January 2022 using Pubmed, CINAHL and SPORTDiscus using a systematic search. Data recorded included the description of the markerless system, clinical outcome measures, and biomechanical data mapped to the International Classification of Functioning, Disability and Health Framework (ICF). Studies were grouped by patient population. Results A total of 50 studies were included for data collection. Use cases for single camera markerless motion capture technology were identified for Neurological Injury in Children and Adults; Hereditary/Genetic Neuromuscular Disorders; Frailty; and Orthopaedic or Musculoskeletal groups. Single camera markerless systems were found to perform well in studies involving single plane measurements, such as in the analysis of infant general movements or spatiotemporal parameters of gait, when evaluated against 3D marker-based systems and a variety of clinical outcome measures. However, they were less capable than marker-based systems in studies requiring the tracking of detailed 3D kinematics or fine movements such as finger tracking. Conclusions Single camera markerless motion capture offers great potential for extending the scope of movement analysis outside of laboratory settings in a practical way, but currently suffers from a lack of accuracy where detailed 3D kinematics are required for clinical decision making. Future work should therefore focus on improving tracking accuracy of movements that are out of plane relative to the camera orientation or affected by occlusion, such as supination and pronation of the forearm.
Collapse
Affiliation(s)
- Bradley Scott
- School of Medicine, Medical Sciences and Nutrition, University of Aberdeen, Aberdeen, United Kingdom
| | - Martin Seyres
- School of Engineering, University of Aberdeen, Aberdeen, United Kingdom
| | - Fraser Philp
- School of Health Sciences, University of Liverpool, Liverpool, United Kingdom
| | | | - Dimitra Blana
- School of Medicine, Medical Sciences and Nutrition, University of Aberdeen, Aberdeen, United Kingdom
| |
Collapse
|
8
|
Martin JR, Gabriel P, Gold J, Haas R, Davis S, Gonda D, Sharpe C, Wilson S, Nierenberg N, Scheuer M, Wang S. Optical Flow Estimation Improves Automated Seizure Detection in Neonatal EEG. J Clin Neurophysiol 2022; 39:235-239. [PMID: 32810002 PMCID: PMC7887141 DOI: 10.1097/wnp.0000000000000767] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE Existing automated seizure detection algorithms report sensitivities between 43% and 77% and specificities between 56% and 90%. The algorithms suffer from false alarms when applied to neonatal EEG because of the high degree of nurse handling and rhythmic patting used to soothe neonates. Computer vision technology that quantifies movement in real time could distinguish artifactual motion and improve automated neonatal seizure detection algorithms. METHODS The authors used video EEG recordings from 43 neonates undergoing monitoring for seizures as part of the NEOLEV2 clinical trial. The Persyst neonatal automated seizure detection algorithm ran in real time during study EEG acquisitions. Computer vision algorithms were applied to extract detailed accounts of artifactual movement of the neonate or people near the neonate though dense optical flow estimation. RESULTS Using the methods mentioned above, 197 periods of patting activity were identified and quantified, of which 45 generated false-positive automated seizure detection events. A binary patting detection algorithm was trained with a subset of 470 event videos. This supervised detection algorithm was applied to a testing subset of 187 event videos with 8 false-positive events, which resulted in a 24% reduction in false-positive automated seizure detections and a 50% reduction in false-positive events caused by neonatal care patting, while maintaining 11 of 12 true-positive seizure detection events. CONCLUSIONS This work presents a novel approach to improving automated seizure detection algorithms used during neonatal video EEG monitoring. This artifact detection mechanism can improve the ability of a seizure detector algorithm to distinguish between artifact and true seizure activity.
Collapse
Affiliation(s)
- Joel R Martin
- Department of Electrical Engineering, University of California, San Diego, La Jolla, CA
| | - Paolo Gabriel
- Department of Electrical Engineering, University of California, San Diego, La Jolla, CA
| | - Jeffrey Gold
- Department of Neurosciences, University of California, San Diego, La Jolla, CA
| | - Richard Haas
- Department of Pediatrics, University of California, San Diego, La Jolla, CA
| | - Sue Davis
- Auckland District Health Board, Auckland, New Zealand
| | - David Gonda
- Department of Surgery, University of California, San Diego, La Jolla, CA
| | - Cia Sharpe
- Department of Pediatrics, University of California, San Diego, La Jolla, CA
| | | | | | | | - Sonya Wang
- Department of Neurology, University of Minnesota, Minneapolis, MN
| |
Collapse
|
9
|
Estimating pose from pressure data for smart beds with deep image-based pose estimators. APPL INTELL 2022. [DOI: 10.1007/s10489-021-02418-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
10
|
Chiang S, Picard RW, Chiong W, Moss R, Worrell GA, Rao VR, Goldenholz DM. Guidelines for Conducting Ethical Artificial Intelligence Research in Neurology: A Systematic Approach for Clinicians and Researchers. Neurology 2021; 97:632-640. [PMID: 34315785 PMCID: PMC8480407 DOI: 10.1212/wnl.0000000000012570] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 07/08/2021] [Indexed: 11/15/2022] Open
Abstract
Pre-emptive recognition of the ethical implications of study design and algorithm choices in artificial intelligence (AI) research is an important but challenging process. AI applications have begun to transition from a promising future to clinical reality in neurology. As the clinical management of neurology is often concerned with discrete, often unpredictable, and highly consequential events linked to multimodal data streams over long timescales, forthcoming advances in AI have great potential to transform care for patients. However, critical ethical questions have been raised with implementation of the first AI applications in clinical practice. Clearly, AI will have far-reaching potential to promote, but also to endanger, ethical clinical practice. This article employs an anticipatory ethics approach to scrutinize how researchers in neurology can methodically identify ethical ramifications of design choices early in the research and development process, with a goal of pre-empting unintended consequences that may violate principles of ethical clinical care. First, we discuss the use of a systematic framework for researchers to identify ethical ramifications of various study design and algorithm choices. Second, using epilepsy as a paradigmatic example, anticipatory clinical scenarios that illustrate unintended ethical consequences are discussed, and failure points in each scenario evaluated. Third, we provide practical recommendations for understanding and addressing ethical ramifications early in methods development stages. Awareness of the ethical implications of study design and algorithm choices that may unintentionally enter AI is crucial to ensuring that incorporation of AI into neurology care leads to patient benefit rather than harm.
Collapse
Affiliation(s)
- Sharon Chiang
- Department of Neurology and Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, CA
| | - Rosalind W Picard
- Empatica Inc., Boston, MA and The Media Lab, Massachusetts Institute of Technology, Cambridge, MA
| | - Winston Chiong
- Department of Neurology and Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, CA
| | | | | | - Vikram R Rao
- Department of Neurology and Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, CA
| | | |
Collapse
|
11
|
Vilas-Boas MDC, Rocha AP, Cardoso MN, Fernandes JM, Coelho T, Cunha JPS. Supporting the Assessment of Hereditary Transthyretin Amyloidosis Patients Based On 3-D Gait Analysis and Machine Learning. IEEE Trans Neural Syst Rehabil Eng 2021; 29:1350-1362. [PMID: 34252029 DOI: 10.1109/tnsre.2021.3096433] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Hereditary Transthyretin Amyloidosis (vATTR-V30M) is a rare and highly incapacitating sensorimotor neuropathy caused by an inherited mutation (Val30Met), which typically affects gait, among other symptoms. In this context, we investigated the possibility of using machine learning (ML) techniques to build a model(s) that can be used to support the detection of the Val30Met mutation (possibility of developing the disease), as well as symptom onset detection for the disease, given the gait characteristics of a person. These characteristics correspond to 24 gait parameters computed from 3-D body data, provided by a Kinect v2 camera, acquired from a person while walking towards the camera. To build the model(s), different ML algorithms were explored: k-nearest neighbors, decision tree, random forest, support vector machines (SVM), and multilayer perceptron. For a dataset corresponding to 66 subjects (25 healthy controls, 14 asymptomatic mutation carriers, and 27 patients) and several gait cycles per subject, we were able to obtain a model that distinguishes between controls and vATTR-V30M mutation carriers (with or without symptoms) with a mean accuracy of 92% (SVM). We also obtained a model that distinguishes between asymptomatic and symptomatic carriers with a mean accuracy of 98% (SVM). These results are very relevant, since this is the first study that proposes a ML approach to support vATTR-V30M patient assessment based on gait, being a promising foundation for the development of a computer-aided diagnosis tool to help clinicians in the identification and follow-up of this disease. Furthermore, the proposed method may also be used for other neuropathies.
Collapse
|
12
|
McGonigal A, Bartolomei F, Chauvel P. On seizure semiology. Epilepsia 2021; 62:2019-2035. [PMID: 34247399 DOI: 10.1111/epi.16994] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/23/2021] [Accepted: 06/23/2021] [Indexed: 12/30/2022]
Abstract
The clinical expression of seizures represents the main symptomatic burden of epilepsy. Neural mechanisms of semiologic production in epilepsy, especially for complex behaviors, remain poorly known. In a framework of epilepsy as a network rather than as a focal disorder, we can think of semiology as being dynamically produced by a set of interconnected structures, in which specific rhythmic interactions, and not just anatomical localization, are likely to play an important part in clinical expression. This requires a paradigm shift in how we think about seizure organization, including from a presurgical evaluation perspective. Semiology is a key data source, albeit with significant methodological challenges for its use in research, including observer bias and choice of semiologic categories. Better understanding of semiologic categorization and pathophysiological correlates is relevant to seizure classification systems. Advances in knowledge of neural mechanisms as well as anatomic correlates of different semiologic patterns could help improve knowledge of epilepsy networks and potentially contribute to therapeutic innovations.
Collapse
Affiliation(s)
- Aileen McGonigal
- Inserm, INS, Institut de Neurosciences des Systèmes, Aix Marseille Univ, Marseille, France.,Clinical Neurophysiology, APHM, Timone Hospital, Marseille, France
| | - Fabrice Bartolomei
- Inserm, INS, Institut de Neurosciences des Systèmes, Aix Marseille Univ, Marseille, France.,Clinical Neurophysiology, APHM, Timone Hospital, Marseille, France
| | - Patrick Chauvel
- Department of Neurology, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| |
Collapse
|
13
|
Benson A, Shahwan A. Monitoring the frequency and duration of epileptic seizures: "A journey through time". Eur J Paediatr Neurol 2021; 33:168-178. [PMID: 34120833 DOI: 10.1016/j.ejpn.2021.05.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 01/19/2021] [Accepted: 05/25/2021] [Indexed: 11/28/2022]
Abstract
Seizure monitoring plays an undeniably important role in diagnosing and managing epileptic seizures. Establishing the frequency and duration of seizures is crucial for assessing the burden of this chronic neurological disease, selecting treatment methods, determining how frequently these methods are applied, and informing short and long-term therapeutic decisions. Over the years, seizure monitoring tools and methods have evolved and become increasingly sophisticated; from home seizure diaries to EEG monitoring to cutting-edge responsive neurostimulation systems. In this article, the various methods of seizure monitoring are reviewed.
Collapse
Affiliation(s)
- Ailbhe Benson
- Department of Clinical Neurophysiology & Neurology, CHI at Temple Street, Dublin, Ireland.
| | - Amre Shahwan
- Department of Clinical Neurophysiology & Neurology, CHI at Temple Street, Dublin, Ireland.
| |
Collapse
|
14
|
Pediaditis M, Ciubotaru AN, Brunschwiler T, Hilfiker P, Grunwald T, Ha Berlin M, Imbach L, Muroi C, Stra Ssle C, Keller E, Gabrani M. Machine Learning Techniques for Personalized Detection of Epileptic Events in Clinical Video Recordings. AMIA ... ANNUAL SYMPOSIUM PROCEEDINGS. AMIA SYMPOSIUM 2021; 2020:1003-1011. [PMID: 33936476 PMCID: PMC8075529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Continuous patient monitoring is essential to achieve an effective and optimal patient treatment in the intensive care unit. In the specific case of epilepsy it is the only way to achieve a correct diagnosis and a subsequent optimal medication plan if possible. In addition to automatic vital sign monitoring, epilepsy patients need manual monitoring by trained personnel, a task that is very difficult to be performed continuously for each patient. Moreover, epileptic manifestations are highly personalized even within the same type of epilepsy. In this work we assess two machine learning methods, dictionary learning and an autoencoder based on long short-term memory (LSTM) cells, on the task of personalized epileptic event detection in videos, with a set of features that were specifically developed with an emphasis on high motion sensitivity. According to the strengths of each method we have selected different types of epilepsy, one with convulsive behaviour and one with very subtle motion. The results on five clinical patients show a highly promising ability of both methods to detect the epileptic events as anomalies deviating from the stable/normal patient status.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Lukas Imbach
- Neurology Clinic, University Hospital, Zurich, Switzerland
| | - Carl Muroi
- Neuro-Intensive Care Unit, Dept. of Neurosrgery and Institute for Intensive Care Medicine, University Hospital Zurich, Switzerland
| | - Christian Stra Ssle
- Neuro-Intensive Care Unit, Dept. of Neurosrgery and Institute for Intensive Care Medicine, University Hospital Zurich, Switzerland
| | - Emanuela Keller
- Neuro-Intensive Care Unit, Dept. of Neurosrgery and Institute for Intensive Care Medicine, University Hospital Zurich, Switzerland
| | | |
Collapse
|
15
|
Ojanen P, Knight A, Hakala A, Bondarchik J, Noachtar S, Peltola J, Kaufmann E. An integrative method to quantitatively detect nocturnal motor seizures. Epilepsy Res 2020; 169:106486. [PMID: 33310414 DOI: 10.1016/j.eplepsyres.2020.106486] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 08/14/2020] [Accepted: 10/12/2020] [Indexed: 11/28/2022]
Abstract
In this proof-of-concept investigation, we demonstrate a marker-free video-based method to detect nocturnal motor seizures across a spectrum of motor seizure types, in a nighttime setting with a single adult female with refractory epilepsy. In doing so, we further explore the intermediate biosignals, visually mapping seizure "fingerprints" to seizure types. The method is designed to be flexible enough to generalize to unseen data, and shows promising performance characteristics for low-cost seizure detection and classification. The dataset contained recordings from 27 recorded nights. Seizure events were observed in 22 of these nights, with 36 unequivocally confirmed seizures. Each seizure was classified by an expert epileptologist according to both the ILAE 2017 standard and the Lüders semiological classification guidelines, yielding 5 of the ILAE-recognized seizure types and 7 distinct seizure semiologies. Evaluation was based on inference of motion, oscillation, and sound signals extracted from the recordings. The model architecture consisted of two feature extraction and event determination layers and one thresholding layer, establishing a simple framework for multimodal seizure analysis. Training of the optimal parameters was done by randomly resampling the event hits for each signal, and choosing a threshold that kept an expected 90 % sensitivity for the sample distribution. With the cut-off values selected, statistical performance was calculated for two target seizure groups: those containing a clonic component, and those containing a tonic component. When tuned to 90 % sensitivity, the system achieved a very low false discovery rate of 0.038/hour when targeting seizures with a clonic component, and a clinically-relevant rate of 1.02/hour when targeting seizures with a tonic component. These results indicate a sensitive method for detecting various nocturnal motor seizure types, and a high potential to differentiate motor seizures based on their video and audio signal characteristics. Paired with the low cost of this technique, both cost savings and improved quality of care might be achieved through further development and commercialization of this method.
Collapse
Affiliation(s)
- Petri Ojanen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
| | | | | | | | | | - Jukka Peltola
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland; Department of Neurology, Tampere University Hospital, Tampere, Finland
| | | |
Collapse
|
16
|
Brunnhuber F, Slater J, Goyal S, Amin D, Thorvardsson G, Freestone DR, Richardson MP. Past, Present and Future of Home video‐electroencephalographic telemetry: A review of the development of in‐home video‐electroencephalographic recordings. Epilepsia 2020; 61 Suppl 1:S3-S10. [DOI: 10.1111/epi.16578] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 05/21/2020] [Accepted: 05/21/2020] [Indexed: 02/06/2023]
Affiliation(s)
| | | | - Sushma Goyal
- King's College Hospital London UK
- Evelina Children's Hospital London UK
| | | | | | | | | |
Collapse
|
17
|
Rhythmic rocking stereotypies in frontal lobe seizures: A quantified video study. Neurophysiol Clin 2020; 50:75-80. [DOI: 10.1016/j.neucli.2020.02.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 02/15/2020] [Accepted: 02/15/2020] [Indexed: 11/23/2022] Open
|
18
|
Ahmedt-Aristizabal D, Sarfraz MS, Denman S, Nguyen K, Fookes C, Dionisio S, Stiefelhagen R. Motion Signatures for the Analysis of Seizure Evolution in Epilepsy. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:2099-2105. [PMID: 31946315 DOI: 10.1109/embc.2019.8857743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In epilepsy, semiology refers to the study of patient behavior and movement, and their temporal evolution during epileptic seizures. Understanding semiology provides clues to the cerebral networks underpinning the epileptic episode and is a vital resource in the pre-surgical evaluation. Recent advances in video analytics have been helpful in capturing and quantifying epileptic seizures. Nevertheless, the automated representation of the evolution of semiology, as examined by neurologists, has not been appropriately investigated. From initial seizure symptoms until seizure termination, motion patterns of isolated clinical manifestations vary over time. Furthermore, epileptic seizures frequently evolve from one clinical manifestation to another, and their understanding cannot be overlooked during a presurgery evaluation. Here, we propose a system capable of computing motion signatures from videos of face and hand semiology to provide quantitative information on the motion, and the correlation between motions. Each signature is derived from a sparse saliency representation established by the magnitude of the optical flow field. The developed computer-aided tool provides a novel approach for physicians to analyze semiology as a flow of signals without interfering in the healthcare environment. We detect and quantify semiology using detectors based on deep learning and via a novel signature scheme, which is independent of the amount of data and seizure differences. The system reinforces the benefits of computer vision for non-obstructive clinical applications to quantify epileptic seizures recorded in real-life healthcare conditions.
Collapse
|
19
|
Validation of a Single RGB-D Camera for Gait Assessment of Polyneuropathy Patients. SENSORS 2019; 19:s19224929. [PMID: 31726742 PMCID: PMC6891607 DOI: 10.3390/s19224929] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 10/29/2019] [Accepted: 11/08/2019] [Indexed: 12/26/2022]
Abstract
Motion analysis systems based on a single markerless RGB-D camera are more suitable for clinical practice than multi-camera marker-based reference systems. Nevertheless, the validity of RGB-D cameras for motor function assessment in some diseases affecting gait, such as Transthyretin Familial Amyloid Polyneuropathy (TTR-FAP), is yet to be investigated. In this study, the agreement between the Kinect v2 and a reference system for obtaining spatiotemporal and kinematic gait parameters was evaluated in the context of TTR-FAP. 3-D body joint data provided by both systems were acquired from ten TTR-FAP symptomatic patients, while performing ten gait trials. For each gait cycle, we computed several spatiotemporal and kinematic gait parameters. We then determined, for each parameter, the Bland Altman’s bias and 95% limits of agreement, as well as the Pearson’s and concordance correlation coefficients, between systems. The obtained results show that an affordable, portable and non-invasive system based on an RGB-D camera can accurately obtain most of the studied gait parameters (excellent or good agreement for eleven spatiotemporal and one kinematic). This system can bring more objectivity to motor function assessment of polyneuropathy patients, potentially contributing to an improvement of TTR-FAP treatment and understanding, with great benefits to the patients’ quality of life.
Collapse
|
20
|
Ahmedt-Aristizabal D, Nguyen K, Denman S, Sridharan S, Dionisio S, Fookes C. Deep Motion Analysis for Epileptic Seizure Classification. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2018:3578-3581. [PMID: 30441151 DOI: 10.1109/embc.2018.8513031] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Visual motion clues such as facial expression and pose are natural semiology features which an epileptologist observes to identify epileptic seizures. However, these cues have not been effectively exploited for automatic detection due to the diverse variations in seizure appearance within and between patients. Here we present a multi-modal analysis approach to quantitatively classify patients with mesial temporal lobe (MTLE) and extra-temporal lobe (ETLE) epilepsy, relying on the fusion of facial expressions and pose dynamics. We propose a new deep learning approach that leverages recent advances in Convolutional Neural Networks (CNN) and Long Short-Term Memory (LSTM) networks to automatically extract spatiotemporal features from facial and pose semiology using recorded videos. A video dataset from 12 patients with MTLE and 6 patients with ETLEin an Australian hospital has been collected for experiments. Our experiments show that facial semiology and body movements can be effectively recognized and tracked, and that they provide useful evidence to identify the type of epilepsy. A multi-fold cross-validation of the fusion model exhibited an average test accuracy of 92.10%, while a leave-one-subject-out cross-validation scheme, which is the first in the literature, achieves an accuracy of 58.49%. The proposed approach is capable of modelling semiology features which effectively discriminate between seizures arising from temporal and extra-temporal brain areas. Our approach can be used as a virtual assistant, which will save time, improve patient safety and provide objective clinical analysis to assist with clinical decision making.
Collapse
|
21
|
Vilas-Boas MDC, Choupina HMP, Rocha AP, Fernandes JM, Cunha JPS. Full-body motion assessment: Concurrent validation of two body tracking depth sensors versus a gold standard system during gait. J Biomech 2019; 87:189-196. [PMID: 30914189 DOI: 10.1016/j.jbiomech.2019.03.008] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 03/04/2019] [Accepted: 03/08/2019] [Indexed: 11/25/2022]
Abstract
RGB-D cameras provide 3-D body joint data in a low-cost, portable and non-intrusive way, when compared with reference motion capture systems used in laboratory settings. In this contribution, we evaluate the validity of both Microsoft Kinect versions (v1 and v2) for motion analysis against a Qualisys system in a simultaneous protocol. Two different walking directions in relation to the Kinect (towards - WT, and away - WA) were explored. For each gait trial, measures related with all body parts were computed: velocity of all joints, distance between symmetrical joints, and angle at some joints. For each measure, we compared each Kinect version and Qualisys by obtaining the mean true error and mean absolute error, Pearson's correlation coefficient, and optical-to-depth ratio. Although both Kinect v1 and v2 and/or WT and WA data present similar accuracy for some measures, better results were achieved, overall, when using WT data provided by the Kinect v2, especially for velocity measures. Moreover, the velocity and distance presented better results than angle measures. Our results show that both Kinect versions can be an alternative to more expensive systems such as Qualisys, for obtaining distance and velocity measures as well as some angles metrics (namely the knee angles). This conclusion is important towards the off-lab non-intrusive assessment of motor function in different areas, including sports and healthcare.
Collapse
Affiliation(s)
- Maria do Carmo Vilas-Boas
- Institute for Systems Engineering and Computers - Technology and Science (INESC TEC), and Faculty of Engineering (FEUP), University of Porto, 4200-391 Porto, Portugal
| | - Hugo Miguel Pereira Choupina
- Institute for Systems Engineering and Computers - Technology and Science (INESC TEC), and Faculty of Engineering (FEUP), University of Porto, 4200-391 Porto, Portugal
| | - Ana Patrícia Rocha
- Institute of Electronics and Informatics Engineering of Aveiro (IEETA), and Department of Electronics, Telecommunications and Informatics, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
| | - José Maria Fernandes
- Institute of Electronics and Informatics Engineering of Aveiro (IEETA), and Department of Electronics, Telecommunications and Informatics, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
| | - João Paulo Silva Cunha
- Institute for Systems Engineering and Computers - Technology and Science (INESC TEC), and Faculty of Engineering (FEUP), University of Porto, 4200-391 Porto, Portugal.
| |
Collapse
|
22
|
Ahmedt-Aristizabal D, Denman S, Nguyen K, Sridharan S, Dionisio S, Fookes C. Understanding Patients' Behavior: Vision-Based Analysis of Seizure Disorders. IEEE J Biomed Health Inform 2019; 23:2583-2591. [PMID: 30714935 DOI: 10.1109/jbhi.2019.2895855] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A substantial proportion of patients with functional neurological disorders (FND) are being incorrectly diagnosed with epilepsy because their semiology resembles that of epileptic seizures (ES). Misdiagnosis may lead to unnecessary treatment and its associated complications. Diagnostic errors often result from an overreliance on specific clinical features. Furthermore, the lack of electrophysiological changes in patients with FND can also be seen in some forms of epilepsy, making diagnosis extremely challenging. Therefore, understanding semiology is an essential step for differentiating between ES and FND. Existing sensor-based and marker-based systems require physical contact with the body and are vulnerable to clinical situations such as patient positions, illumination changes, and motion discontinuities. Computer vision and deep learning are advancing to overcome these limitations encountered in the assessment of diseases and patient monitoring; however, they have not been investigated for seizure disorder scenarios. Here, we propose and compare two marker-free deep learning models, a landmark-based and a region-based model, both of which are capable of distinguishing between seizures from video recordings. We quantify semiology by using either a fusion of reference points and flow fields, or through the complete analysis of the body. Average leave-one-subject-out cross-validation accuracies for the landmark-based and region-based approaches of 68.1% and 79.6% in our dataset collected from 35 patients, reveal the benefit of video analytics to support automated identification of semiology in the challenging conditions of a hospital setting.
Collapse
|
23
|
Ahmedt-Aristizabal D, Fookes C, Denman S, Nguyen K, Fernando T, Sridharan S, Dionisio S. A hierarchical multimodal system for motion analysis in patients with epilepsy. Epilepsy Behav 2018; 87:46-58. [PMID: 30173017 DOI: 10.1016/j.yebeh.2018.07.028] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 07/30/2018] [Accepted: 07/30/2018] [Indexed: 10/28/2022]
Abstract
During seizures, a myriad of clinical manifestations may occur. The analysis of these signs, known as seizure semiology, gives clues to the underlying cerebral networks involved. When patients with drug-resistant epilepsy are monitored to assess their suitability for epilepsy surgery, semiology is a vital component to the presurgical evaluation. Specific patterns of facial movements, head motions, limb posturing and articulations, and hand and finger automatisms may be useful in distinguishing between mesial temporal lobe epilepsy (MTLE) and extratemporal lobe epilepsy (ETLE). However, this analysis is time-consuming and dependent on clinical experience and training. Given this limitation, an automated analysis of semiological patterns, i.e., detection, quantification, and recognition of body movement patterns, has the potential to help increase the diagnostic precision of localization. While a few single modal quantitative approaches are available to assess seizure semiology, the automated quantification of patients' behavior across multiple modalities has seen limited advances in the literature. This is largely due to multiple complicated variables commonly encountered in the clinical setting, such as analyzing subtle physical movements when the patient is covered or room lighting is inadequate. Semiology encompasses the stepwise/temporal progression of signs that is reflective of the integration of connected neuronal networks. Thus, single signs in isolation are far less informative. Taking this into account, here, we describe a novel modular, hierarchical, multimodal system that aims to detect and quantify semiologic signs recorded in 2D monitoring videos. Our approach can jointly learn semiologic features from facial, body, and hand motions based on computer vision and deep learning architectures. A dataset collected from an Australian quaternary referral epilepsy unit analyzing 161 seizures arising from the temporal (n = 90) and extratemporal (n = 71) brain regions has been used in our system to quantitatively classify these types of epilepsy according to the semiology detected. A leave-one-subject-out (LOSO) cross-validation of semiological patterns from the face, body, and hands reached classification accuracies ranging between 12% and 83.4%, 41.2% and 80.1%, and 32.8% and 69.3%, respectively. The proposed hierarchical multimodal system is a potential stepping-stone towards developing a fully automated semiology analysis system to support the assessment of epilepsy.
Collapse
Affiliation(s)
- David Ahmedt-Aristizabal
- The Speech, Audio, Image and Video Technologies (SAIVT) research group, School of Electrical Engineering & Computer Science, Queensland University of Technology, Australia.
| | - Clinton Fookes
- The Speech, Audio, Image and Video Technologies (SAIVT) research group, School of Electrical Engineering & Computer Science, Queensland University of Technology, Australia
| | - Simon Denman
- The Speech, Audio, Image and Video Technologies (SAIVT) research group, School of Electrical Engineering & Computer Science, Queensland University of Technology, Australia
| | - Kien Nguyen
- The Speech, Audio, Image and Video Technologies (SAIVT) research group, School of Electrical Engineering & Computer Science, Queensland University of Technology, Australia
| | - Tharindu Fernando
- The Speech, Audio, Image and Video Technologies (SAIVT) research group, School of Electrical Engineering & Computer Science, Queensland University of Technology, Australia
| | - Sridha Sridharan
- The Speech, Audio, Image and Video Technologies (SAIVT) research group, School of Electrical Engineering & Computer Science, Queensland University of Technology, Australia
| | - Sasha Dionisio
- Department of Mater Advanced Epilepsy Unit, Mater Centre for Neurosciences, Brisbane, Australia
| |
Collapse
|
24
|
Rasche L, Scheel M, Otte K, Althoff P, van Vuuren AB, Gieß RM, Kuchling J, Bellmann-Strobl J, Ruprecht K, Paul F, Brandt AU, Schmitz-Hübsch T. MRI Markers and Functional Performance in Patients With CIS and MS: A Cross-Sectional Study. Front Neurol 2018; 9:718. [PMID: 30210439 PMCID: PMC6123531 DOI: 10.3389/fneur.2018.00718] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 08/08/2018] [Indexed: 01/04/2023] Open
Abstract
Introduction: Brain atrophy is a widely accepted marker of disease severity with association to clinical disability in multiple sclerosis (MS). It is unclear to which extent this association reflects common age effects on both atrophy and function. Objective: To explore how functional performance in gait, upper extremities and cognition is associated with brain atrophy in patients with Clinically Isolated Syndrome (CIS) and relapsing-remitting MS (RRMS), controlling for effects of age and sex. Methods: In 27 patients with CIS, 59 with RRMS (EDSS ≤3) and 63 healthy controls (HC), 3T MRI were analyzed for T2 lesion count (T2C), volume (T2V) and brain volumes [normalized brain volume (NBV), gray matter volume (NGMV), white matter volume (NWMV), thalamic volume (NThalV)]. Functional performance was measured with short maximum walking speed (SMSW speed), 9-hole peg test (9HPT) and symbol digit modalities test (SDMT). Linear regression models were created for functional variables with stepwise inclusion of age, sex and MR imaging markers. Results: CIS differed from HC only in T2C and T2V. RRMS differed from HC in NBV, NGMV and NThalV, T2C and T2V, but not in NWMV. A strong association with age was seen in HC, CIS and RRMS groups for NBV (r = -0.5 to -0.6) and NGMV (r = -0.6 to -0.8). Associations with age were seen in HC and RRMS but not CIS for NThalV (r = -0.3; r = -0.5), T2C (rs = 0.3; rs = 0.2) and T2V (rs = 0.3; rs = 0.3). No effect of age was seen on NWMV. Correlations of functional performance with age in RRMS were seen for SMSW speed, 9HPTand SDMT (r = -0.27 to -0.46). Regression analyses yielded significant models only in the RRMS group for 9HPT, SMSW speed and EDSS. These included NBV, NGMV, NThalV, NWMV, logT2V, age and sex as predictors. NThalV was the only MRI variable predicting a functional measure (9HPTr) with a higher standardized beta than age and sex (R2 = 0.36, p < 1e-04). Conclusion: Thalamic atrophy was a stronger predictor of hand function (9HPT) in RRMS, than age and sex. This underlines the clinical relevance of thalamic atrophy and the relevance of hand function as a clinical marker even in mildly disabled patients.
Collapse
Affiliation(s)
- Ludwig Rasche
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
| | - Michael Scheel
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
- Department of Neuroradiology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Karen Otte
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
- Motognosis GmbH, Berlin, Germany
| | - Patrik Althoff
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
| | - Annemieke B. van Vuuren
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
- VU University Medical Center, Amsterdam, Netherlands
| | - Rene M. Gieß
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
| | - Joseph Kuchling
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
- Department of Neurology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Judith Bellmann-Strobl
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
- Experimental and Clinical Research Center, Charité - Universitätsmedizin Berlin Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health and Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Klemens Ruprecht
- Department of Neurology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Friedemann Paul
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
- Department of Neurology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Experimental and Clinical Research Center, Charité - Universitätsmedizin Berlin Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health and Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Alexander U. Brandt
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
- Department of Neurology, University of California, Irvine, Irvine, CA, United States
| | - Tanja Schmitz-Hübsch
- NeuroCure Clinical Research Center, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, NeuroCure Cluster of Excellence, Berlin, Germany
| |
Collapse
|
25
|
Macedonia M, Hammer F, Weichselbaum O. Guided Embodiment and Potential Applications of Tutor Systems in Language Instruction and Rehabilitation. Front Psychol 2018; 9:927. [PMID: 29951017 PMCID: PMC6008518 DOI: 10.3389/fpsyg.2018.00927] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Accepted: 05/22/2018] [Indexed: 11/13/2022] Open
Abstract
Intelligent tutor systems (ITSs) in mobile devices take us through learning tasks and make learning ubiquitous, autonomous, and at low cost (Nye, 2015). In this paper, we describe guided embodiment as an ITS essential feature for second language learning (L2) and aphasia rehabilitation (ARe) that enhances efficiency in the learning process. In embodiment, cognitive processes, here specifically language (re)learning are grounded in actions and gestures (Pecher and Zwaan, 2005; Fischer and Zwaan, 2008; Dijkstra and Post, 2015). In order to guide users through embodiment, ITSs must track action and gesture, and give corrective feed-back to achieve the users' goals. Therefore, sensor systems are essential to guided embodiment. In the next sections, we describe sensor systems that can be implemented in ITS for guided embodiment.
Collapse
Affiliation(s)
- Manuela Macedonia
- Information Engineering, Johannes Kepler Universität Linz, Linz, Austria.,Neural Mechanisms of Human Communication, Max-Planck-Institut für Kognitions- und Neurowissenschaften, Leipzig, Germany
| | | | - Otto Weichselbaum
- Information Engineering, Johannes Kepler Universität Linz, Linz, Austria.,Sew Systems Gmbh, Linz, Austria
| |
Collapse
|
26
|
Do Carmo Vilas-Boas M, Rocha AP, Pereira Choupina HM, Fernandes JM, Coelho T, Silva Cunha JP. The first Transthyretin Familial Amyloid Polyneuropathy gait quantification study - preliminary results. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:1368-1371. [PMID: 29060131 DOI: 10.1109/embc.2017.8037087] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Transthyretin Familial Amyloid Polyneuropathy (TTR-FAP) is a rare neurological disease caused by a genetic mutation with a variable presentation and consequent challenging diagnosis, complex follow-up and treatment. At this moment, this condition has no cure and treatment options are under development. One of the disease's implications is a definite and progressive motor impairment that from the early stages compromises walking ability and daily life activities. The detection of this impairment is key for the disease onset diagnosis. With the goal of improving diagnosis of the symptoms and patients' quality of life, the authors have assessed the gait characteristics of subjects suffering from this condition. This contribution shows the results of a preliminary study, using a non-intrusive, markerless vision-based gait analysis tool. To the best of our knowledge, the reported results constitute the first gait analysis data of TTR-FAP mutation carriers.
Collapse
|
27
|
Ahmedt-Aristizabal D, Fookes C, Dionisio S, Nguyen K, Cunha JPS, Sridharan S. Automated analysis of seizure semiology and brain electrical activity in presurgery evaluation of epilepsy: A focused survey. Epilepsia 2017; 58:1817-1831. [DOI: 10.1111/epi.13907] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/28/2017] [Indexed: 11/28/2022]
Affiliation(s)
- David Ahmedt-Aristizabal
- The Speech, Audio, Image and Video Technologies (SAIVT) and Science and Engineering Faculty; Queensland University of Technology; Brisbane Queensland Australia
| | - Clinton Fookes
- The Speech, Audio, Image and Video Technologies (SAIVT) and Science and Engineering Faculty; Queensland University of Technology; Brisbane Queensland Australia
| | - Sasha Dionisio
- Mater Centre for Neurosciences; Brisbane Queensland Australia
| | - Kien Nguyen
- The Speech, Audio, Image and Video Technologies (SAIVT) and Science and Engineering Faculty; Queensland University of Technology; Brisbane Queensland Australia
| | - João Paulo S. Cunha
- The Institute of Systems and Computer Engineering; Technology and Science; and Faculty of Engineering; University of Porto; Porto Portugal
| | - Sridha Sridharan
- The Speech, Audio, Image and Video Technologies (SAIVT) and Science and Engineering Faculty; Queensland University of Technology; Brisbane Queensland Australia
| |
Collapse
|
28
|
Silva Cunha JP, Rocha AP, Pereira Choupina HM, Fernandes JM, Rosas MJ, Vaz R, Achilles F, Loesch AM, Vollmar C, Hartl E, Noachtar S. A novel portable, low-cost kinect-based system for motion analysis in neurological diseases. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:2339-2342. [PMID: 28268795 DOI: 10.1109/embc.2016.7591199] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Many neurological diseases, such as Parkinson's disease and epilepsy, can significantly impair the motor function of the patients, often leading to a dramatic loss of their quality of life. Human motion analysis is regarded as fundamental towards an early diagnosis and enhanced follow-up in this type of diseases. In this contribution, we present NeuroKinect, a novel system designed for motion analysis in neurological diseases. This system includes an RGB-D camera (Microsoft Kinect) and two integrated software applications, KiT (KinecTracker) and KiMA (Kinect Motion Analyzer). The applications enable the preview, acquisition, review and management of data provided by the sensor, which are then used for motion analysis of relevant events. NeuroKinect is a portable, low-cost and markerless solution that is suitable for use in the clinical environment. Furthermore, it is able to provide quantitative support to the clinical assessment of different neurological diseases with movement impairments, as demonstrated by its usage in two different clinical routine scenarios: gait analysis in Parkinson's disease and seizure semiology analysis in epilepsy.
Collapse
|
29
|
Vilas-Boas MDC, Cunha JPS. Movement Quantification in Neurological Diseases: Methods and Applications. IEEE Rev Biomed Eng 2016; 9:15-31. [PMID: 27008673 DOI: 10.1109/rbme.2016.2543683] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
30
|
Achilles F, Ichim AE, Coskun H, Tombari F, Noachtar S, Navab N. Patient MoCap: Human Pose Estimation Under Blanket Occlusion for Hospital Monitoring Applications. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION – MICCAI 2016 2016. [DOI: 10.1007/978-3-319-46720-7_57] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|