Li W, Lu H, Wen Y, Zhou M, Shuai T, You Y, Zhao J, Liao K, Lu C, Li J, Li Z, Diao K, He Y. Reducing both radiation and contrast doses for overweight patients in coronary CT angiography with 80-kVp and deep learning image reconstruction. Eur J Radiol 2023; 161:110736. [PMID: 36804314 DOI: 10.1016/j.ejrad.2023.110736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 02/03/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023]
Abstract
PURPOSE To investigate the use of an 80-kVp tube voltage combined with a deep learning image reconstruction (DLIR) algorithm in coronary CT angiography (CCTA) for overweight patients to reduce radiation and contrast doses in comparison with the 120-kVp protocol and adaptive statistical iterative reconstruction (ASIR-V). METHODS One hundred consecutive CCTA patients were prospectively enrolled and randomly divided into a low-dose group (n = 50) with 80-kVp, smart mA for noise index (NI) of 36 HU, contrast dose rate of 18 mgI/kg/s and DLIR and 60 % ASIR-V and a standard-dose group (n = 50) with 120-kVp, smart mA for NI of 25 HU, contrast dose rate of 32 mgI/kg/s and 60 % ASIR-V. The radiation and contrast dose, subjective image quality score, attenuation values, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared. RESULTS The low-dose group achieved a significant reduction in the effective radiation dose (1.01 ± 0.45 mSv vs 1.85 ± 0.40 mSv, P < 0.001) and contrast dose (33.69 ± 3.87 mL vs 59.11 ± 5.60 mL, P < 0.001) compared to the standard-dose group. The low-dose group with DLIR presented similar enhancement but lower noise, higher SNR and CNR and higher subjective quality scores than the standard-dose group. Moreover, the same patient comparison in the low-dose group between different reconstructions showed that DLIR images had slightly and consistently higher CT values in small vessels, indicating better defined vessels, much lower image noise, higher SNR and CNR and higher subjective quality scores than ASIR-V images (all P < 0.001). CONCLUSIONS The application of 80-kVp and DLIR allows for significant radiation and dose reduction while further improving image quality in CCTA for overweight patients.
Collapse
Affiliation(s)
- Wanjiang Li
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Haiyan Lu
- Department of Respiratory and Critical Care Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Yuting Wen
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Minggang Zhou
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Tao Shuai
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Yongchun You
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Jin Zhao
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Kai Liao
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Chunyan Lu
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | | | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
| | - Kaiyue Diao
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China.
| | - Yong He
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
2
|
Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography. PLoS One 2020; 15:e0236108. [PMID: 32673356 PMCID: PMC7365455 DOI: 10.1371/journal.pone.0236108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/29/2020] [Indexed: 11/19/2022] Open
Abstract
Background To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30. Materials and methods A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100–350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100–450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed. Results The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all of p > 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 ± 0.48 mSv) and C (2.72 ± 0.54 mSv), compared with group A (3.58 ± 0.67 mSv) (p < 0.05). Conclusion CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.
Collapse
|
3
|
Li T, Tang T, Yang L, Zhang X, Li X, Luo C. Coronary CT Angiography with Knowledge-Based Iterative Model Reconstruction for Assessing Coronary Arteries and Non-Calcified Predominant Plaques. Korean J Radiol 2020; 20:729-738. [PMID: 30993924 PMCID: PMC6470089 DOI: 10.3348/kjr.2018.0435] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2018] [Accepted: 01/21/2019] [Indexed: 11/15/2022] Open
Abstract
Objective To assess the effects of iterative model reconstruction (IMR) on image quality for demonstrating non-calcific high-risk plaque characteristics of coronary arteries. Materials and Methods This study included 66 patients (53 men and 13 women; aged 39–76 years; mean age, 55 ± 13 years) having single-vessel disease with predominantly non-calcified plaques evaluated using prospective electrocardiogram-gated 256-slice CT angiography. Paired image sets were created using two types of reconstruction: hybrid iterative reconstruction (HIR) and IMR. Plaque characteristics were compared using the two algorithms. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images and the CNR between the plaque and adjacent adipose tissue were also compared between the two reformatted methods. Results Seventy-seven predominantly non-calcified plaques were detected. Forty plaques showed napkin-ring sign with the IMR reformatted method, while nineteen plaques demonstrated napkin-ring sign with HIR. There was no statistically significant difference in the presentation of positive remodeling, low attenuation plaque, and spotty calcification between the HIR and IMR reconstructed methods (all p > 0.5); however, there was a statistically significant difference in the ability to discern the napkin-ring sign between the two algorithms (χ2 = 12.12, p < 0.001). The image noise of IMR was lower than that of HIR (10 ± 2 HU versus 12 ± 2 HU; p < 0.01), and the SNR and CNR of the images and the CNR between plaques and surrounding adipose tissues on IMR were better than those on HIR (p < 0.01). Conclusion IMR can significantly improve image quality compared with HIR for the demonstration of coronary artery and atherosclerotic plaques using a 256-slice CT.
Collapse
Affiliation(s)
- Tao Li
- Department of Radiology, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Tian Tang
- Department of Radiology, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Li Yang
- Department of Radiology, Chinese People's Liberation Army General Hospital, Beijing, China.
| | - Xinghua Zhang
- Department of Radiology, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Xueping Li
- Department of Radiology, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Chuncai Luo
- Department of Radiology, Chinese People's Liberation Army General Hospital, Beijing, China
| |
Collapse
|
4
|
Lee J, Kim TH, Lee BK, Yoon YW, Kwon HM, Hong BK, Min PK, Choi EY, Oh CS, Park CH. Diagnostic accuracy of low-radiation coronary computed tomography angiography with low tube voltage and knowledge-based model reconstruction. Sci Rep 2019; 9:1308. [PMID: 30718631 PMCID: PMC6362232 DOI: 10.1038/s41598-018-37870-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 12/10/2018] [Indexed: 12/23/2022] Open
Abstract
We aimed to evaluate the accuracy of coronary computed tomography angiography (CCTA) with a low-radiation protocol and iterative model reconstruction (IMR), in comparison with invasive coronary angiography (ICA). Sixty-one patients (45 males; mean age, 61.9 ± 9.2 years) with suspected coronary artery disease who underwent CCTA and ICA were retrospectively enrolled. CCTA was performed with low tube voltage (80 or 100 kVp), low tube current (100–200 mAs), prospective ECG triggering, and IMR using a 64-slice computed tomography scanner. Coronary artery disease was defined as luminal narrowing of >50%, as assessed using CCTA and ICA. The sensitivity, specificity, positive (PPV) and negative (NPV) predictive value, and accuracy of CCTA were examined. The mean radiation dose of CCTA was 1.05 ± 0.36 mSv. No non-diagnostic segment was noted. The sensitivity, specificity, PPV, NPV, and accuracy of CCTA were 86.4%, 96.1%, 80.3%, 97.5%, and 94.6% on a per segment basis, 93.1%, 94.7%, 88.3%, 97.0%, and 94.2% on a per vessel basis, and 100%, 83.3%, 93.5%, 100%, and 95.1% on a per patient basis, respectively. In conclusion, a low-radiation CCTA protocol with IMR may be useful for diagnosing coronary artery disease, as it reduces the radiation dose while maintaining diagnostic accuracy.
Collapse
Affiliation(s)
- Joohee Lee
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Tae Hoon Kim
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Byoung Kwon Lee
- Division of Cardiology, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Young Won Yoon
- Division of Cardiology, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hyuck Moon Kwon
- Division of Cardiology, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Bum Kee Hong
- Division of Cardiology, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Pil-Ki Min
- Division of Cardiology, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Eui-Young Choi
- Division of Cardiology, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chi Suk Oh
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chul Hwan Park
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
| |
Collapse
|
5
|
Park IK, Park J, Kim TH, Lee J, Han K, Oh C, Park CH. Non-inferior low-dose coronary computed tomography angiography image quality with knowledge-based iterative model reconstruction for overweight patients. PLoS One 2018; 13:e0209243. [PMID: 30586449 PMCID: PMC6306215 DOI: 10.1371/journal.pone.0209243] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 12/03/2018] [Indexed: 11/29/2022] Open
Abstract
We investigated the feasibility of low-dose coronary computed tomography angiography (CCTA), using a prospective electrocardiogram (ECG)-triggered axial scan protocol, knowledge-based iterative model reconstruction (IMR), and fixed tube current, in overweight subjects. Forty non-overweight (group A; body-mass index [BMI] < 25 kg/m2) and 40 overweight individuals (group B; BMI = 25–30 kg/m2), who underwent CCTA for coronary artery disease screening, were retrospectively and consecutively enrolled. A 64-slice CT scanner was used at 100-kVp tube voltage and 150-mA tube current, and images were reconstructed using IMR techniques. Image noise, attenuation at the aorta, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) at the proximal right and left main coronary arteries (pRCA and LMCA) were calculated. CCTA images were qualitatively evaluated using a four-point scale (1, poor; 4, excellent) and analyzed using a non-inferiority test with a pre-defined non-inferiority margin of -0.2. The mean CCTA radiation dose (Group A: 1.33 ± 0.02 mSv; Group B: 1.35 ± 0.10 mSv; p = 0.151) and mean aortic root CT attenuation values (Group A: 447.9 ± 81.6 HU; Group B: 439.5 ± 63.6 HU; p = 0.571) did not differ significantly between the two groups. The mean noise in groups A and B was 26.0 ± 4.8 HU and 29.2 ± 4.4 HU, respectively (p = 0.005). The noise reduction ratio in the groups, compared to filtered back projection, was 65.0% and 68.1%, respectively. The mean grade of image quality did not differ significantly (3.75 ± 0.04 vs. 3.71 ± 0.04, p = 0.478). Group B CCTA image quality was non-inferior (mean difference = -0.043, 95% CI = -0.162–0.077) to that of Group A. We concluded that low-dose CCTA with prospective ECG-triggering and IMR might be applied to overweight subjects, as well as to normal-weight subjects, by using a fixed tube current without an increase in tube current based on the patient’s body size.
Collapse
Affiliation(s)
- In Kyung Park
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jeffrey Park
- College of Letters and Science, University of California Berkeley, Berkeley, CA, United States of America
| | - Tae Hoon Kim
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Joohee Lee
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chisuk Oh
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chul Hwan Park
- Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
- * E-mail:
| |
Collapse
|
6
|
Qu TT, Li JY, Jiao XJ, Zhang XL, Song ZF, Guo YX, Guo JX. Contrast dose reduction with shortened injection durations in coronary CT angiography on 16-cm Wide-detector CT scanner. Br J Radiol 2018; 91:20180580. [PMID: 30160183 PMCID: PMC6319827 DOI: 10.1259/bjr.20180580] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 08/12/2018] [Accepted: 08/14/2018] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVES: To investigate the use of shortened contrast injection with late triggering in coronary CT angiography (CCTA) for decreasing contrast dose and maintaining image quality. METHODS: 106 patients for CCTA on a 16-cm wide-detector CT were prospectively enrolled into groups A (n = 50) and B (n = 56) randomly. Patient weight-dependent contrast medium (Iopamiro, 370 mgI ml-1) at dose rate of 25 mgI/kg/s was used with 8 s and the standard 10 s injection time in groups A and B, respectively. CT values of the aortic sinus (AS), right coronary artery, left anterior descending and left circumflex at the proximal, middle and distal segments were measured and compared. Subjective image quality was evaluated and analyzed with Fisher exact test. Contrast dose, injection rate and enhancement duration (between the start of enhancement in AS and scan finish) were also compared. RESULTS: There was no difference in the injection rate and enhancement duration between the two groups (p > 0.05), while the total contrast dose in group A (36.2 ± 5.7 ml) was significantly lower than in group B (46.4 ± 6.3 ml) (p < 0.001). There was no difference for CT values in all major coronary vessels between the two groups and no difference in subjective image quality scores (all p > 0.05). CONCLUSION: It is feasible to shorten contrast injection to 8 s in CCTA on wide-detector CT systems to significantly reduce contrast dosage, maintain adequate enhancement and reduce contrast-related artifacts. ADVANCES IN KNOWLEDGE: (1) Coronary CT angiography (CCTA) scans with shortened contrast medium injection duration and late triggering are feasible with a 16-cm wide-detector CT system (2) Compared with the conventional CCTA with 10 s contrast injection duration, the new contrast injection protocol of using shortened injection duration (to 8 s) and late triggering reduces contrast dose to 36.2 ml, while maintaining adequate enhancement in vessels and reducing contrast-related artifacts.
Collapse
Affiliation(s)
- Ting-ting Qu
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, PR China
| | - Jian-ying Li
- CT Research Center, GE Healthcare China, Beijing, China
| | - Xi-jun Jiao
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, PR China
| | - Xiang-li Zhang
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, PR China
| | - Zhe-fan Song
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, PR China
| | - Yin-xia Guo
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, PR China
| | - Jian-xin Guo
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, PR China
| |
Collapse
|
7
|
Patel AA, Sutphin PD, Xi Y, Abbara S, Kalva SP. Arterial Phase CTA Replacement by a Virtual Arterial Phase Reconstruction from a Venous Phase CTA: Preliminary Results Using Detector-Based Spectral CT. Cardiovasc Intervent Radiol 2018; 42:250-259. [DOI: 10.1007/s00270-018-2096-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 10/12/2018] [Indexed: 11/25/2022]
|