1
|
Ma Y, Chen R, Zhang R, Liang J, Ren S, Gao Z. Application of DNA-fueled molecular machines in food safety testing. Compr Rev Food Sci Food Saf 2024; 23:1-22. [PMID: 38284608 DOI: 10.1111/1541-4337.13299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 01/30/2024]
Abstract
Food is consumed by humans, which is indispensable to human life. Therefore, considerable attention of the whole society has been paid to food safety. Over the last few years, dramatic social development has brought new challenges to food safety, making developing new and quick methods for on-site food safety testing an important necessity. As a result, DNA-fueled molecular machines, characterized by high efficiency, accuracy, and sensitivity in testing, have come into the spotlight, based on which sensors can be constructed to detect toxic and harmful substances in food products. This study reviewed recent research on several DNA-fueled molecular machines, including DNA tweezers, DNA walkers, and DNA origami, for rapidly detecting toxic and harmful substances. Based on the above studies, the sensitivity and timeliness of several DNA molecular machines were summarized and compared, and the development prospect of DNA fuel molecular machines in the field of food safety detection was prospected.
Collapse
Affiliation(s)
- Yujing Ma
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin, China
| | - Ruipeng Chen
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
| | - Rui Zhang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin, China
| | - Jun Liang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin, China
| | - Shuyue Ren
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
| | - Zhixian Gao
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
| |
Collapse
|
2
|
Manage DP, Lauzon J, Pilarski LM, Pilarski PM, McMullen LM. Comparison of a Miniaturized Cassette PCR System with a Commercially Available Platform for Detecting Escherichia coli in Beef Carcass Swabs. MICROMACHINES 2021; 12:mi12080959. [PMID: 34442581 PMCID: PMC8398369 DOI: 10.3390/mi12080959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 08/07/2021] [Accepted: 08/08/2021] [Indexed: 12/05/2022]
Abstract
Detection sensitivity of cassette PCR was compared with a commercial BAX® PCR system for detection of eae and stx genes in Escherichia coli from 806 beef carcass swabs. Cassette PCR detects multiple genetic markers on multiple samples using PCR and melt curve analysis. Conventional PCR served as a gold standard. Overall, for positive and negative concordance, cassette PCR was 98.6% concordant with conventional PCR, and BAX PCR was 65.4% concordant. Of 806 beef carcass swabs, 339 by cassette PCR and 84 by BAX PCR harbored eae + stx+E. coli. For BAX PCR reactions, 84% of eae+ swabs, 79% of stx+ swabs, and 86% of eae + stx+ swabs were also detected by cassette PCR. For cassette PCR reactions, 457 swabs were eae+ with only 117 scored as eae+ using BAX PCR for 26% positive concordance. For stx primers, cassette PCR scored 480 samples as stx+ but only 215 samples were stx+ by BAX PCR, giving 45% positive concordance. Importantly, cassette PCR scored 339 swabs as harboring eae + stx+ E. coli, but BAX PCR detected only 71 positives giving only 21% positive concordance, with many false negatives. Cassette PCR is a highly sensitive method for detection of STEC genes in E. coli found in carcass swabs.
Collapse
Affiliation(s)
- Dammika P. Manage
- Department of Agricultural, Food and Nutritional Science, University of Alberta, 4-10 Ag/For Centre, Edmonton, AB T6G 2P5, Canada; (D.P.M.); (J.L.)
| | - Jana Lauzon
- Department of Agricultural, Food and Nutritional Science, University of Alberta, 4-10 Ag/For Centre, Edmonton, AB T6G 2P5, Canada; (D.P.M.); (J.L.)
| | - Linda M. Pilarski
- Department of Oncology, University of Alberta and Cross Cancer Institute, 11560 University Ave, Edmonton, AB T6G 1Z2, Canada;
| | - Patrick M. Pilarski
- 5-005 Katz Group Centre for Pharmacy and Health Research, Department of Medicine, Division of Physical Medicine & Rehabilitation, University of Alberta, Edmonton, AB T6G 2E1, Canada;
| | - Lynn M. McMullen
- Department of Agricultural, Food and Nutritional Science, University of Alberta, 4-10 Ag/For Centre, Edmonton, AB T6G 2P5, Canada; (D.P.M.); (J.L.)
- Correspondence:
| |
Collapse
|
3
|
Manage DP, Lauzon J, Jones CM, Ward PJ, Pilarski LM, Pilarski PM, McMullen LM. Detection of pathogenic Escherichia coli on potentially contaminated beef carcasses using cassette PCR and conventional PCR. BMC Microbiol 2019; 19:175. [PMID: 31362696 PMCID: PMC6668150 DOI: 10.1186/s12866-019-1541-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2018] [Accepted: 07/11/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Over a one year period, swabs of 820 beef carcasses were tested for the presence of Shiga toxin-producing Escherichia coli by performing Polymerase Chain Reaction (PCR) in a novel technology termed "cassette PCR", in comparison to conventional liquid PCR. Cassette PCR is inexpensive and ready-to-use. The operator need only add the sample and press "go". Cassette PCR can simultaneously test multiple samples for multiple targets. Carcass swab samples were first tested for the presence of STEC genes (O157, eae, stx1 and stx2). Samples were considered to be pathogenic if positive for eae plus stx1 and/or stx2. For samples scored as pathogenic, further testing screened for 6 additional high frequency O-antigens (O26, O45, O103, O111, O121, and O145). RESULTS Of the 820 samples, 41% were pathogenic and 30% were O157 positive. Of these, 19% of samples were positive for O157 and carried potentially pathogenic E. coli (eae plus stx1 and/or stx2). Of all samples identified as carrying pathogenic E. coli, 18.9, 38.8, 41.4, 0, 36.1, and 4.1% respectively were positive for O26, O45, O103, O111, O121, and O145. To validate cassette PCR testing, conventional PCR using STEC primers was performed on each of the 820 samples. Only 148 of 3280 cassette PCR tests were discordant with conventional PCR results. However, further fractional testing showed that 110 of these 148 PCRs reflected low numbers of E. coli in the enrichment broth and could be explained as due to Poisson limiting dilution of the template, affecting both cassette PCR and conventional PCR. Of the remaining 38 discordant tests, 27 initial capillary PCRs and 10 initial conventional tests were nominally discordant between cassette and conventional PCR, perhaps reflecting human/technical error on both sides of the comparison. CONCLUSIONS Contaminated beef carcass swabs were often complex, likely harboring more than one strain of pathogenic E. coli. Cassette PCR had 98.8% concordance with parallel conventional PCR for detection of STEC genes. This indicates that cassette PCR is highly reliable for detecting multiple pathogens in beef carcass swabs from processing plants.
Collapse
Affiliation(s)
- Dammika P Manage
- Department of Oncology, University of Alberta and Cross Cancer Institute, 11560 University Ave, Edmonton, AB, T6G 1Z2, Canada
| | - Jana Lauzon
- Department of Oncology, University of Alberta and Cross Cancer Institute, 11560 University Ave, Edmonton, AB, T6G 1Z2, Canada
| | - Christina M Jones
- Department of Oncology, University of Alberta and Cross Cancer Institute, 11560 University Ave, Edmonton, AB, T6G 1Z2, Canada
| | - Patrick J Ward
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, T6G 2P5, Canada
| | - Linda M Pilarski
- Department of Oncology, University of Alberta and Cross Cancer Institute, 11560 University Ave, Edmonton, AB, T6G 1Z2, Canada
| | - Patrick M Pilarski
- Division of Physical Medicine & Rehabilitation, Department of Medicine, University of Alberta, 5-005 Katz Group Centre for Pharmacy and Health Research, Edmonton, AB, T6G 2E1, Canada
| | - Lynn M McMullen
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, T6G 2P5, Canada.
| |
Collapse
|
4
|
Manage DP, Lauzon J, McMullen LM, Pilarski LM. Application of lab-on-a-chip multiplex cassette PCR for the detection of enterohemorrhagic Escherichia coli. BMC Microbiol 2019; 19:93. [PMID: 31088365 PMCID: PMC6515682 DOI: 10.1186/s12866-019-1463-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Accepted: 04/23/2019] [Indexed: 11/20/2022] Open
Abstract
Background Fast molecular detection methods benefit from ready-to-run lab-on-a-chip molecular assays with minimum preparation time. Detection efficiency of such methods can improve if multiple targets are detected simultaneously per given reaction. Detection of food pathogens, i.e. Escherichia coli (E. coli), is generally performed in two stages with the detection of multiple targets in each stage.With simultaneous testing, screening for pathogens is fast and efficient. Results In this study, we show the application of multiplex PCR performed on a ready-made cassette to detect 10 targets each for eight samples known to harbor E. coli. In cassette PCR, the aluminum cassette (38.6 mm × 31.4 mm) contains 10 trenches having a total of 50 capillaries with microliter volumes of desiccated acrylamide gels holding all reagents required for the PCR including internal positive and negative controls. The gel contains LCGreen dye to detect double stranded DNA. Fluorescence monitoring allows the detection of the amplified products by melt curve analysis. In this application, each of the five capillaries in a given trench contains two of the primer sets for the detection of 10 targets in pathogenic E. coli, namely, O157, Eae, Stx1, Stx2 and six O-antigen genes. Primer specificity was confirmed. Each trench tests one sample. Eight minimally processed enriched beef carcass swab samples were analyzed for parallel detection of 10 targets within 1 h and 15 min. Samples were delivered to the capillaries by capillary forces thereby hydrating the gels. Multiplex cassette PCR results were confirmed with conventional multiplex PCRs performed in a commercial real-time PCR system. Conclusions Cassette PCR technology is ideally suited to multi-target detection of pathogens in food products. The cassette performs multiple PCR reactions in parallel, with multiplex detection of targets within each reaction unit. Cassette PCR/ melt curve analysis results for the simultaneous detection of 10 targets of pathogenic E.coli in beef carcass swab samples were confirmed with a conventional real-time PCR/ melt curve analysis as well as with agarose gel electrophoresis. Although designed for the detection of E. coli, this multiplex cassette PCR technique can be applied to any other assay where the fast detection of multiple targets is required.
Collapse
Affiliation(s)
- Dammika P Manage
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, AB, T6G 2P5, Canada.
| | - Jana Lauzon
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, AB, T6G 2P5, Canada
| | - Lynn M McMullen
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, AB, T6G 2P5, Canada
| | - Linda M Pilarski
- Department of Oncology, University of Alberta and Cross Cancer Institute, 11560 University Ave, Edmonton, AB, T6G 1Z2, Canada
| |
Collapse
|