1
|
Nishioka N, Fujima N, Tsuneta S, Yoneyama M, Matsumoto R, Abe T, Kimura R, Sakamoto K, Kato F, Kudo K. Clinical utility of single-shot echo-planar diffusion-weighted imaging using L1-regularized iterative sensitivity encoding in prostate MRI. Medicine (Baltimore) 2023; 102:e33639. [PMID: 37115048 PMCID: PMC10146059 DOI: 10.1097/md.0000000000033639] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 04/05/2023] [Accepted: 04/06/2023] [Indexed: 04/29/2023] Open
Abstract
We investigated the ability of echo-planar imaging with L1-regularized iterative sensitivity encoding-based diffusion-weighted imaging (DWI) to improve the image quality and reduce the scanning time in prostate magnetic resonance imaging. We retrospectively analyzed 109 cases of prostate magnetic resonance imaging. We compared variables in the quantitative and qualitative assessments among 3 imaging groups: conventional parallel imaging-based DWI (PI-DWI) with an acquisition time of 3 minutes 15 seconds; echo-planar imaging with L1-regularized iterative sensitivity encoding-based DWI (L1-DWI) with a normal acquisition time (L1-DWINEX12) of 3 minutes 15 seconds; and L1-DWI with a half acquisition time (L1-DWINEX6) of 1 minute 45 seconds. As a quantitative assessment, the signal-to-noise ratio (SNR) of DWI (SNR-DWI), the contrast-to-noise ratio (CNR) of DWI (CNR-DWI), and the CNR of apparent diffusion coefficient were measured. As a qualitative assessment, the image quality and visual detectability of prostate carcinoma were evaluated. In the quantitative analysis, L1-DWINEX12 showed significantly higher SNR-DWI than PI-DWI (P = .0058) and L1-DWINEX6 (P < .0001). In the qualitative analysis, the image quality score for L1-DWINEX12 was significantly higher than those of PI-DWI and L1-DWINEX6. A non-inferiority assessment demonstrated that L1-DWINEX6 was non-inferior to PI-DWI in terms of both quantitative CNR-DWI and qualitative grading of image quality with a <20% inferior margin. L1-DWI successfully demonstrated a reduced scanning time while maintaining good image quality.
Collapse
Affiliation(s)
- Noriko Nishioka
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita-Ku, Sapporo, Japan
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-Ku, Sapporo, Japan
| | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita-Ku, Sapporo, Japan
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita-Ku, Sapporo, Japan
| | | | - Ryuji Matsumoto
- Department of Renal and Genitourinary Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-Ku, Sapporo, Japan
| | - Takashige Abe
- Department of Renal and Genitourinary Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-Ku, Sapporo, Japan
| | - Rina Kimura
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita-Ku, Sapporo, Japan
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-Ku, Sapporo, Japan
| | - Keita Sakamoto
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita-Ku, Sapporo, Japan
| | - Fumi Kato
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita-Ku, Sapporo, Japan
| | - Kohsuke Kudo
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita-Ku, Sapporo, Japan
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-Ku, Sapporo, Japan
- Department of Advanced Diagnostic Imaging Development, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-Ku, Sapporo, Japan
- Global Center for Biomedical Science and Engineering, Faculty of Medicine, Hokkaido University, Kita-Ku, Sapporo, Hokkaido, Japan
| |
Collapse
|
2
|
He W, Chen X, Hu R, Sun W, Tan W. Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging. Front Surg 2022; 9:862697. [PMID: 35449554 PMCID: PMC9018106 DOI: 10.3389/fsurg.2022.862697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 02/21/2022] [Indexed: 11/13/2022] Open
Abstract
Objective To explore the influence of a contrast agent injection scheme customized by dual-source CT based on automatic tube voltage technology on coronary imaging image quality and radiation dose. Methods A total of 205 patients who underwent coronary CT angiography (CCTA) in our hospital from June 2021 to September 2021 were selected. 105 patients in the control group who underwent routine scanning according to body mass (BMI) and 100 patients in the observation group who set tube voltage and contrast agent dosage according to automatic tube voltage selection technology. CT values of the aortic root (AO); left anterior descending (LAD) branch; proximal, middle, and distal segments of the right coronary artery (RCA); and proximal and distal segments of left circumflex (LCX) branch were measured. We calculated the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the image. Image quality scoring and effective dose (ED) calculation were carried out. Results There was no significant difference in the CT value, SNR value, and CNR value of each part of the artery between the two groups (P > 0.05). Image quality scores of the control group and the observation group were 1.28 ± 0.25 and 1.25 ± 0.23, respectively, and there was no significant difference in scores (P > 0.05). In the control group, the dosage of comparator was 43.81 ± 6.74 ml, and the ED was 4.92 ± 1.26 mSv. The dosage of contrast agent in the observation group was 34.23 ± 6.39 ml, and ED was 3.05 ± 0.94 mSv. The dosage of contrast agent and ED in the observation group were lower than those in the control group (P < 0.05). Conclusion The contrast agent injection scheme customized by dual-source CT based on automatic tube voltage technology can meet the clinical requirements of coronary image quality, reduce the radiation dose and contrast agent consumption, and help doctors choose a more accurate and reasonable examination scheme, which has certain clinical application value.
Collapse
Affiliation(s)
- Weiling He
- Department of Radiology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Xin Chen
- Diagnostic Radiology Department, Hunan Cancer Hospital, Changsha, China
| | - Rui Hu
- Interventional Vascular Surgery Department, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Wenjie Sun
- Department of Radiology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Weili Tan
- Diagnostic Radiology Department, Hunan Cancer Hospital, Changsha, China
- *Correspondence: Weili Tan
| |
Collapse
|
3
|
Ki HJ, Kim BS, Kim JK, Choi JH, Shin YS, Choi Y, Shin NY, Jang J, Ahn KJ. Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose. Korean J Radiol 2022; 23:256-263. [PMID: 35029071 PMCID: PMC8814704 DOI: 10.3348/kjr.2021.0162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 09/29/2021] [Accepted: 09/30/2021] [Indexed: 11/25/2022] Open
Abstract
Objective This study aimed to evaluate the image quality and dose reduction of low-dose three-dimensional (3D) rotational angiography (RA) for evaluating intracranial aneurysms. Materials and Methods We retrospectively evaluated the clinical data and 3D RA datasets obtained from 146 prospectively registered patients (male:female, 46:100; median age, 58 years; range, 19–81 years). The subjective image quality of 79 examinations obtained from a conventional method and 67 examinations obtained from a low-dose (5-seconds and 0.10-µGy/frame) method was assessed by two neurointerventionists using a 3-point scale for four evaluation criteria. The total image quality score was then obtained as the average of the four scores. The image quality scores were compared between the two methods using a noninferiority statistical testing, with a margin of -0.2 (i.e., score of low-dose group – score of conventional group). For the evaluation of dose reduction, dose-area product (DAP) and air kerma (AK) were analyzed and compared between the two groups. Results The mean total image quality score ± standard deviation of the 3D RA was 2.97 ± 0.17 by reader 1 and 2.95 ± 0.20 by reader 2 for conventional group and 2.92 ± 0.30 and 2.95 ± 0.22, respectively, for low-dose group. The image quality of the 3D RA in the low-dose group was not inferior to that of the conventional group according to the total image quality score as well as individual scores for the four criteria in both readers. The mean DAP and AK per rotation were 5.87 Gy-cm2 and 0.56 Gy, respectively, in the conventional group, and 1.32 Gy-cm2 (p < 0.001) and 0.17 Gy (p < 0.001), respectively, in the low-dose group. Conclusion Low-dose 3D RA was not inferior in image quality and reduced the radiation dose by 70%–77% compared to the conventional 3D RA in evaluating intracranial aneurysms.
Collapse
Affiliation(s)
- Hee Jong Ki
- Department of Neurosurgery, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Bum-Soo Kim
- Department of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
| | - Jun-Ki Kim
- Department of Neurosurgery, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Jai Ho Choi
- Department of Neurosurgery, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Yong Sam Shin
- Department of Neurosurgery, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Yangsean Choi
- Department of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Na-Young Shin
- Department of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Jinhee Jang
- Department of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Kook-Jin Ahn
- Department of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| |
Collapse
|
4
|
Liu ZC, Zhao S, Ma ZP, Zhang TL, Zhao YX. Comparing feasibility of different tube voltages and different concentrations of contrast medium in coronary CT angiography of overweight patients. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:1261-1272. [PMID: 36214032 DOI: 10.3233/xst-221263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
OBJECTIVES To compare image quality, radiation dose, and iodine intake of coronary computed tomography angiography (CCTA) acquired by wide-detector using different tube voltages and different concentrations of contrast medium (CM) for overweight patients. MATERIALS AND METHODS A total of 150 overweight patients (body mass index≥25 kg/m2) who underwent CCTA are enrolled and divided into three groups according to scan protocols namely, group A (120 kVp, 370 mgI/ml CM); group B (100 kVp, 350 mgI/ml CM); and group C (80 kVp, 320 mgI/ml CM). The CT values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure-of-merit (FOM) of all images are calculated. Images are subjectively assessed using a 5-point scale. In addition, the CT dose index volume (CTDIvol) and dose length product (DLP) of each patient are recorded. The effective radiation dose (ED) is also calculated. Above data are then statistically analyzed. RESULTS The mean CT values, SNR, CNR, and subjective image quality of group A are significantly lower than those of groups B and C (P < 0.001), but there is no significant difference between groups B and C (P > 0.05). FOMs show a significantly increase trend from group A to C (P < 0.001). The ED values and total iodine intake in groups B and C are 30.34% and 68.53% and 10.22% and 16.85% lower than those in group A, respectively (P < 0.001). CONCLUSION The lower tube voltage and lower concentration of CM based on wide-detector allows for significant reduction in iodine load and radiation dose in CCTA for overweight patients comparing to routine scan protocols. It also enhances signal intensity of CCTA and maintains image quality.
Collapse
Affiliation(s)
- Zhi-Chao Liu
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Sai Zhao
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Ze-Peng Ma
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Tian-Le Zhang
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Yong-Xia Zhao
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| |
Collapse
|