1
|
Wong J, Kutschera P, Lau KK. Spectral Shaping Computed Tomography Applications. J Comput Assist Tomogr 2025:00004728-990000000-00426. [PMID: 40008966 DOI: 10.1097/rct.0000000000001738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2024] [Accepted: 01/14/2025] [Indexed: 02/27/2025]
Abstract
Spectral shaping (also known as spectral filtration) has been utilized in some of the latest computed tomography (CT) systems. This technique involves using tin (Sn) or silver (Ag) filters, which selectively absorb low-energy photons. This review aims to demonstrate the utility of spectral shaping across a wide range of protocols and clinical situations. Spectral-shaped CT protocols using tin filters allow for the acquisition of diagnostic images and greatly reduce the radiation dose, metal artifacts, and photon starvation. These features make spectral shaping suitable for various clinical situations in diagnostic and interventional CT imaging.
Collapse
Affiliation(s)
| | - Peter Kutschera
- Monash Imaging, Monash Health, Melbourne
- Faculty of Medicine, Nursing & Health Sciences, Monash University, Melbourne, VIC, Australia
| | - Kenneth K Lau
- Monash Imaging, Monash Health, Melbourne
- Faculty of Medicine, Nursing & Health Sciences, Monash University, Melbourne, VIC, Australia
- Sir Peter MacCallum Department of Oncology, University of Melbourne, VIC, Australia
| |
Collapse
|
2
|
Schüle S, Hackenbroch C, Beer M, Ostheim P, Hermann C, Muhtadi R, Stewart S, Port M, Scherthan H, Abend M. Tin prefiltration in computed tomography does not significantly alter radiation-induced gene expression and DNA double-strand break formation. PLoS One 2024; 19:e0315808. [PMID: 39705301 DOI: 10.1371/journal.pone.0315808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2024] [Accepted: 12/02/2024] [Indexed: 12/22/2024] Open
Abstract
BACKGROUND The tin (Sn) prefilter technique is a recently introduced dose-saving technique in computed tomography (CT). This study investigates whether there is an altered molecular biological response in blood cells using the tin prefiltering technique. METHODS Blood from 6 donors was X-irradiated ex-vivo with 20 mGy full dose (FD) protocols (Sn 150 kV, 150 kV, and 120 kV) and a tin prefiltered 16.5 mGy low dose (LD) protocol on a CT scanner. Biological changes were determined by quantification of γH2AX DNA double-strand break (DSB) foci, and differential gene expression (DGE) relative to unexposed samples were examined for seven known radiation-induced genes (FDXR, DDB2, BAX, CDKN1A, AEN, EDA2R, APOBEC3H) and 667 microRNAs (miRNA). RESULTS EDA2R and DDB2 gene expression (GE) increased 1.7-6-fold (p = 0.0004-0.02) and average DNA DSB foci value (0.31±0.02, p<0.0001) increased significantly relative to unexposed samples, but similarly for the applied radiation protocols. FDXR upregulation (2.2-fold) was significant for FD protocols (p = 0.01-0.02) relative to unexposed samples. miRNA GE changes were not significant (p = 0.15-1.00) and DGE were similar for the examined protocols (p = 0.10-1.00). An increased frequency of lower DGE values was seen in the Sn 150 kV LD protocol compared to the 120 kV FD and Sn 150 kV FD protocols (p = 0.001-0.008). CONCLUSIONS The current ex-vivo study indicates no changes regarding transcriptional and post-transcriptional DGE and DNA DSB induction when using the tin prefilter technique and even a significant tendency to lower radiation-induced DGE-changes due to the dose reduction of the tin prefilter with equal image quality compared to classical CT scan protocols was found.
Collapse
Affiliation(s)
- Simone Schüle
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
- Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital of Ulm, Ulm, Baden-Württemberg, Germany
- Department of Radiology, University Hospital of Ulm, Ulm, Baden-Württemberg, Germany
| | - Carsten Hackenbroch
- Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital of Ulm, Ulm, Baden-Württemberg, Germany
- Department of Radiology, University Hospital of Ulm, Ulm, Baden-Württemberg, Germany
| | - Meinrad Beer
- Department of Radiology, University Hospital of Ulm, Ulm, Baden-Württemberg, Germany
| | - Patrick Ostheim
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
- Department of Radiology, University Hospital Regensburg, Regensburg, Bavaria, Germany
| | - Cornelius Hermann
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
| | - Razan Muhtadi
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
| | - Samantha Stewart
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
| | - Matthias Port
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
| | - Harry Scherthan
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
| | - Michael Abend
- Bundeswehr Institute of Radiobiology Affiliated to the University of Ulm, Munich, Bavaria, Germany
| |
Collapse
|
3
|
Kaatsch HL, Fulisch F, Dillinger D, Kubitscheck L, Becker BV, Piechotka J, Brockmann MA, Froelich MF, Schoenberg SO, Overhoff D, Waldeck S. Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT. Dentomaxillofac Radiol 2024; 53:103-108. [PMID: 38330501 DOI: 10.1093/dmfr/twad010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/29/2023] [Accepted: 11/16/2023] [Indexed: 02/10/2024] Open
Abstract
PURPOSE This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy. METHODS This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques. RESULTS Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv ± 0.009 vs. 0.14 mSv ± 0.011; P < .001). CONCLUSION In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT.
Collapse
Affiliation(s)
- Hanns Leonhard Kaatsch
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz 56072, Germany
| | - Florian Fulisch
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz 56072, Germany
| | - Daniel Dillinger
- Department of Vascular Surgery and Endovascular Surgery, Bundeswehr Central Hospital, Koblenz 56072, Germany
| | - Laura Kubitscheck
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz 56072, Germany
- Bundeswehr Institute of Radiobiology affiliated to Ulm University, Munich 80937, Germany
| | - Benjamin V Becker
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz 56072, Germany
- Department of Neuroradiology, University Medical Center Mainz, Mainz 55131, Germany
| | - Joel Piechotka
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz 56072, Germany
| | - Marc A Brockmann
- Department of Neuroradiology, University Medical Center Mainz, Mainz 55131, Germany
| | - Matthias F Froelich
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim 68167, Germany
| | - Stefan O Schoenberg
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim 68167, Germany
| | - Daniel Overhoff
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz 56072, Germany
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim 68167, Germany
| | - Stephan Waldeck
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz 56072, Germany
- Department of Neuroradiology, University Medical Center Mainz, Mainz 55131, Germany
| |
Collapse
|
4
|
Mostafapour S, Greuter M, van Snick JH, Brouwers AH, Dierckx RAJO, van Sluis J, Lammertsma AA, Tsoumpas C. Ultra-low dose CT scanning for PET/CT. Med Phys 2024; 51:139-155. [PMID: 38047554 DOI: 10.1002/mp.16862] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 11/07/2023] [Accepted: 11/13/2023] [Indexed: 12/05/2023] Open
Abstract
BACKGROUND The use of computed tomography (CT) for attenuation correction (AC) in whole-body PET/CT can result in a significant contribution to radiation exposure. This can become a limiting factor for reducing considerably the overall radiation exposure of the patient when using the new long axial field of view (LAFOV) PET scanners. However, recent CT technology have introduced features such as the tin (Sn) filter, which can substantially reduce the CT radiation dose. PURPOSE The purpose of this study was to investigate the ultra-low dose CT for attenuation correction using the Sn filter together with other dose reduction options such as tube current (mAs) reduction. We explore the impact of dose reduction in the context of AC-CT and how it affects PET image quality. METHODS The study evaluated a range of ultra-low dose CT protocols using five physical phantoms that represented a broad collection of tissue electron densities. A long axial field of view (LAFOV) PET/CT scanner was used to scan all phantoms, applying various CT dose reduction parameters such as reducing tube current (mAs), increasing the pitch value, and applying the Sn filter. The effective dose resulting from the CT scans was determined using the CTDIVol reported by the scanner. Several voxel-based and volumes of interest (VOI)-based comparisons were performed to compare the ultra-low dose CT images, the generated attenuation maps, and corresponding PET images against those images acquired with the standard low dose CT protocol. Finally, two patient datasets were acquired using one of the suggested ultra-low dose CT settings. RESULTS By incorporating the Sn filter and adjusting mAs to the lowest available value, the radiation dose in CT images of PBU-60 phantom was significantly reduced; resulting in an effective dose of nearly 2% compared to the routine low dose CT protocols currently in clinical use. The assessment of PET images using VOI and voxel-based comparisons indicated relative differences (RD%) of under 6% for mean activity concentration (AC) in the torso phantom and patient dataset and under 8% for a source point in the CIRS phantom. The maximum RD% value of AC was 14% for the point source in the CIRS phantom. Increasing the tube current from 6 mAs to 30 mAs in patients with high BMI, or with arms down, can suppress the photon starvation artifact, whilst still preserving a dose reduction of 90%. CONCLUSIONS Introducing a Sn filter in CT imaging lowers radiation dose by more than 90%. This reduction has minimal effect on PET image quantification at least for patients without Body Mass Index (BMI) higher than 30. Notably, this study results need validation using a larger clinical PET/CT dataset in the future, including patients with higher BMI.
Collapse
Affiliation(s)
- Samaneh Mostafapour
- Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Marcel Greuter
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Johannes H van Snick
- Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Adrienne H Brouwers
- Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Rudi A J O Dierckx
- Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Joyce van Sluis
- Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Adriaan A Lammertsma
- Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Charalampos Tsoumpas
- Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
5
|
Hackenbroch C, Strobel JRB, Lorenz KJ, Beer M, Schüle S. Dose development in sinonasal imaging over the last decade - a retrospective patient study. Head Face Med 2023; 19:28. [PMID: 37430304 PMCID: PMC10332007 DOI: 10.1186/s13005-023-00378-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 07/01/2023] [Indexed: 07/12/2023] Open
Abstract
BACKGROUND Computed tomography (CT) has become the primary imaging modality for visualization of the paranasal sinuses. In this retrospective, single center patient study the radiation dose development in the past 12 years in CT imaging of the paranasal sinuses was assessed. METHODS The computed tomography dose index (CTDIVol) and dose length product (DLP) of a total of 1246 patients (average age: 41 ± 18 years, 361 females, 885 males) were evaluated, who received imaging of the paranasal sinuses either for chronic sinusitis diagnostic, preoperatively or posttraumatically. Scans were performed on three different CT scanners (Somatom Definition AS, Somatom Definition AS+, Somatom Force, all from Siemens Healthineers) and on one CBCT (Morita) ranging from 2010 to 2022. Reconstruction techniques were filtered back projection and three generations of iterative reconstruction (IRIS, SAFIRE, ADMIRE, all from Siemens Healthineers). Group comparisons were performed using either parametrical (ANOVA) or non-parametrical tests (Kruskal-Wallis Test), where applicable. RESULTS Over the past 12 years, there was a 73%, 54%, and 66% CTDIVol reduction and a significant (p < 0.001) 72%, 33%, and 67% DLP reduction in assessing the paranasal sinuses for chronic sinusitis, preoperatively and posttraumatically, respectively. CONCLUSION Technological developments in CT imaging, both hardware and software based, have led to a significant reduction in dose exposure in recent years. Particularly in imaging of the paranasal sinuses, the reduction of radiation exposure is of great interest due to the often young patient age and radiation-sensitive organs in the area of radiation exposure.
Collapse
Affiliation(s)
- Carsten Hackenbroch
- Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital Ulm, Ulm, Baden-Wurttemberg, Germany.
- Department of Radiology, University Hospital of Ulm, Ulm, Baden-Wurttemberg, Germany.
| | - Joachim Rudolf Balthasar Strobel
- Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital Ulm, Ulm, Baden-Wurttemberg, Germany
| | - Kai Johannes Lorenz
- Department of Otorhinolaryngology and Head and Neck Surgery, German Armed Forces Central Hospital Koblenz, Koblenz, Rhineland-Palatinate, Germany
| | - Meinrad Beer
- Department of Radiology, University Hospital of Ulm, Ulm, Baden-Wurttemberg, Germany
| | - Simone Schüle
- Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital Ulm, Ulm, Baden-Wurttemberg, Germany
| |
Collapse
|