Julius L, Saeed MM, Kuijpers T, Sandu S, Henihan G, Dreo T, Schoen CD, Mishra R, Dunne NJ, Carthy E, Ducrée J, Kinahan DJ. Low-High-Low Rotationally Pulse-Actuated Serial Dissolvable Film Valves Applied to Solid Phase Extraction and LAMP Isothermal Amplification for Plant Pathogen Detection on a Lab-on-a-Disc. ACS OMEGA 2024; 9:3262-3275. [PMID: 38284094 PMCID: PMC10809376 DOI: 10.1021/acsomega.3c05117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 12/13/2023] [Accepted: 12/14/2023] [Indexed: 01/30/2024]
Abstract
The ability of the centrifugal Lab-on-a-Disc (LoaD) platform to closely mimic the "on bench" liquid handling steps (laboratory unit operations (LUOs)) such as metering, mixing, and aliquoting supports on-disc automation of bioassay without the need for extensive biological optimization. Thus, well-established bioassays, normally conducted manually using pipettes or using liquid handling robots, can be relatively easily automated in self-contained microfluidic chips suitable for use in point-of-care or point-of-use settings. The LoaD's ease of automation is largely dependent on valves that can control liquid movement on the rotating disc. The optimum valving strategy for a true low-cost and portable device is rotationally actuated valves, which are actuated by changes in the disc spin-speed. However, due to tolerances in disc manufacturing and variations in reagent properties, most of these valving technologies have inherent variation in their actuation spin-speed. Most valves are actuated through stepped increases in disc spin-speed until the motor reaches its maximum speed (rarely more than 6000 rpm). These manufacturing tolerances combined with this "analogue" mechanism of valve actuation limits the number of LUOs that can be placed on-disc. In this work, we present a novel valving mechanism called low-high-low serial dissolvable film (DF) valves. In these valves, a DF membrane is placed in a dead-end pneumatic chamber. Below an actuation spin-speed, the trapped air prevents liquid wetting and dissolving the membrane. Above this spin-speed, the liquid will enter and wet the DF and open the valve. However, as DFs take ∼40 s to dissolve, the membrane can be wetted, and the disc spin-speed reduced before the film opens. Thus, by placing valves in a series, we can govern on which "digital pulse" in spin-speeding a reagent is released; a reservoir with one serial valve will open on the first pulse, a reservoir with two serial valves on the second, and so on. This "digital" flow control mechanism allows the automation of complex assays with high reliability. In this work, we first describe the operation of the valves, outline the theoretical basis for their operation, and support this analysis with an experiment. Next, we demonstrate how these valves can be used to automate the solid-phase extraction of DNA on on-disc LAMP amplification for applications in plant pathogen detection. The disc was successfully used to extract and detect, from a sample lysed off-disc, DNA indicating the presence of thermally inactivated Clavibacter michiganensis ssp. michiganensis (Cmm), a bacterial pathogen on tomato leaf samples.
Collapse
Affiliation(s)
- Lourdes
AN Julius
- Fraunhofer
Project Centre at Dublin City University, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
- School
of Physical Sciences, Dublin City University, Dublin D09 V209, Ireland
- National
Centre for Sensor Research (NCSR), Dublin
City University, Dublin D09 V209, Ireland
| | - Muhammad Mubashar Saeed
- Biodesign
Europe, Dublin City University, Dublin D09 V209, Ireland
- School
of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
- SFI Centre
for Research Training in Machine Learning (ML-Laboratories), Dublin City University, Dublin D09 V209, Ireland
| | - Tim Kuijpers
- Biodesign
Europe, Dublin City University, Dublin D09 V209, Ireland
- School
of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
| | - Sergei Sandu
- Biodesign
Europe, Dublin City University, Dublin D09 V209, Ireland
- School
of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
| | - Grace Henihan
- Fraunhofer
Project Centre at Dublin City University, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
- School
of Physical Sciences, Dublin City University, Dublin D09 V209, Ireland
- National
Centre for Sensor Research (NCSR), Dublin
City University, Dublin D09 V209, Ireland
| | - Tanja Dreo
- National
Institute of Biology, 1000 Ljubljana, Slovenia
| | - Cor D Schoen
- Wageningen
University and Research, 6708 PB Wageningen, The Netherlands
| | - Rohit Mishra
- Fraunhofer
Project Centre at Dublin City University, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
- School
of Physical Sciences, Dublin City University, Dublin D09 V209, Ireland
- National
Centre for Sensor Research (NCSR), Dublin
City University, Dublin D09 V209, Ireland
| | - Nicholas J Dunne
- Biodesign
Europe, Dublin City University, Dublin D09 V209, Ireland
- School
of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
| | - Eadaoin Carthy
- National
Centre for Sensor Research (NCSR), Dublin
City University, Dublin D09 V209, Ireland
- Biodesign
Europe, Dublin City University, Dublin D09 V209, Ireland
- School
of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
| | - Jens Ducrée
- School
of Physical Sciences, Dublin City University, Dublin D09 V209, Ireland
- National
Centre for Sensor Research (NCSR), Dublin
City University, Dublin D09 V209, Ireland
- Biodesign
Europe, Dublin City University, Dublin D09 V209, Ireland
| | - David J Kinahan
- National
Centre for Sensor Research (NCSR), Dublin
City University, Dublin D09 V209, Ireland
- Biodesign
Europe, Dublin City University, Dublin D09 V209, Ireland
- School
of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin D09 V209, Dublin, Ireland
| |
Collapse
|
2
|
Carthy É, Hughes B, Higgins E, Early P, Merne C, Walsh D, Parle-McDermott A, Kinahan DJ. Automated solid phase DNA extraction on a lab-on-a-disc with two-degrees of freedom instrumentation. Anal Chim Acta 2023; 1280:341859. [PMID: 37858565 DOI: 10.1016/j.aca.2023.341859] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/15/2023] [Accepted: 09/29/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND Lab-on-a-disc (LoaD) technology has emerged as a transformative approach for point-of-care diagnostics and high-throughput testing. The promise of integrating multiple laboratory functions onto a single integrated platform has significant implications for healthcare, especially in resource-limited settings. However, one of the primary challenges faced in the design and manufacture of LoaD devices is the integration of effective valving mechanisms. These valves are essential for fluid control and routing, but their intricacy often leads to complexities in design and increased vulnerability to failure. This emphasizes the need for improved designs and manufacturing processes without complex, integrated valving mechanisms. (96) RESULTS: We describe a fully automated biological workflow and reagent actuation on a LoaD device without an integrated valving system. The Two Degrees-of-Freedom (2DoF) custom centrifuge alters the centre of rotation, facilitating fluid flow direction changes on the microfluidic platform through a custom programmed interface. A novel 360-degree fluid manipulation approach via secondary planetary gear motion enabled sequential assay reagent actuation without embedded valve triggering, with the addition of infinite incubation times and efficient use of platform realty. The simplified LoaD platform uses clever design, with intermediate flow chambers to avoid cross contamination between reagent steps. Notably, the optimized LoaD platform demonstrated a two-fold DNA yield at higher HEK-293 cell concentrations compared to commercially available spin-column kits. This significantly simplified LoaD platform successfully automated a common, complex workflow without inhibiting DNA purification. (129) SIGNIFICANCE: This system exhibits the clever coupling of both 2DoF and centrifugal microfluidics to create an autonomous testing package capable of eradicating the need for complex valving systems to automate biological workflows on LoaDs. This automated system has outperformed commercially available DNA extraction kits for higher cell counts. The platform's elimination of valve requirements ensures unlimited sample incubation times and enhances reliability, making it a straightforward option for automated biological workflows, particularly in diagnostics. (73).
Collapse
Affiliation(s)
- Éadaoin Carthy
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland.
| | - Brian Hughes
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Eimear Higgins
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Phil Early
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Cian Merne
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Darren Walsh
- School of Biotechnology, Dublin City University, Glasnevin, Dublin, Ireland
| | - Anne Parle-McDermott
- National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; School of Biotechnology, Dublin City University, Glasnevin, Dublin, Ireland
| | - David J Kinahan
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland
| |
Collapse
|