1
|
Noise-Reducing Fabric Electrode for ECG Measurement. SENSORS 2021; 21:s21134305. [PMID: 34201874 PMCID: PMC8271945 DOI: 10.3390/s21134305] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 06/21/2021] [Accepted: 06/22/2021] [Indexed: 12/03/2022]
Abstract
In this work, we propose a fabric electrode with a special structure that can play the role of a noise reduction filter. Fabric electrodes made of the conductive fabric have been used for long-term ECG measurements because of their flexibility and non-invasiveness; however, due to the large impedance between the skin and the fabric electrodes, noise is easily introduced into the ECG signal. In contrast to conventional work, in which chip-type passive elements are glued to the electrode to reduce noise, the proposed electrode can obtain a noise-reduced ECG by changing the structure of fabric. Specifically, the proposed electrode was folded multiple times to form a capacitor with a capacitance of about 3 nF. It is combined with the skin-electrode impedance to form a low-pass filter. In the experiment, we made a prototype of the electrodes and measured ECG at rest and during EMG-induced exercise. As a result, the SNR values at rest and during exercise were improved about 12.02 and 10.29 dB, respectively, compared with the fabric electrode without special structure. In conclusion, we have shown that changing the fabric electrode structure effectively removes noise in ECG measurement.
Collapse
|
2
|
Piuzzi E, Pisa S, Pittella E, Podestà L, Sangiovanni S. Wearable Belt With Built-In Textile Electrodes for Cardio-Respiratory Monitoring. SENSORS 2020; 20:s20164500. [PMID: 32806534 PMCID: PMC7472108 DOI: 10.3390/s20164500] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 08/02/2020] [Accepted: 08/10/2020] [Indexed: 12/27/2022]
Abstract
Unobtrusive and continuous monitoring of vital signs is becoming more and more important both for patient monitoring in the home environment and for sports activity tracking. Even though many gadgets and clinical systems exist, the need for simple, low-cost and easily applicable solutions still remains, especially in view of a more widespread use within everyone’s reach. The paper presents a fully wearable and wireless sensorized belt, suitable to simultaneously acquire respiratory and cardiac signals employing a single acquisition channel. The adopted method relies on a 50-kHz current injected in the subject thorax through a couple of textile electrodes and on envelope detection of the trans-thoracic voltage acquired from a couple of different embedded electrodes. The resulting signal contains both the baseband electrocardiogram (ECG) signal and the trans-thoracic impedance signal, which encodes respiratory acts. The two signals can be easily separated through suitable filtering and the cardio–respiratory rates extracted. The proposed solution yields performances comparable to those of a spirometer and a two-lead ECG. The whole system, with a realization cost below 100 €, a wireless interface, and several hours (or even days) of autonomy, is a suitable candidate for everyday use, especially if complemented by motion artifact removal techniques, currently under implementation.
Collapse
Affiliation(s)
- Emanuele Piuzzi
- Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, via Eudossiana 18, 00184 Rome, Italy;
- Correspondence:
| | - Stefano Pisa
- Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, via Eudossiana 18, 00184 Rome, Italy;
| | - Erika Pittella
- Department of Legal and Economic Sciences, Pegaso University, via di S. Pantaleo 66, 00186 Rome, Italy;
| | - Luca Podestà
- Department of Astronautics, Electrical and Energetics Engineering (DIAEE), Sapienza University of Rome, via Eudossiana 18, 00184 Rome, Italy; (L.P.); (S.S.)
| | - Silvia Sangiovanni
- Department of Astronautics, Electrical and Energetics Engineering (DIAEE), Sapienza University of Rome, via Eudossiana 18, 00184 Rome, Italy; (L.P.); (S.S.)
| |
Collapse
|
3
|
Nakamura H, Sakajiri Y, Ishigami H, Ueno A. A Novel Analog Front End with Voltage-Dependent Input Impedance and Bandpass Amplification for Capacitive Biopotential Measurements. SENSORS 2020; 20:s20092476. [PMID: 32349328 PMCID: PMC7249202 DOI: 10.3390/s20092476] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 04/20/2020] [Accepted: 04/24/2020] [Indexed: 11/16/2022]
Abstract
This paper proposes a novel analogue front end (AFE) that has three features: voltage-dependent input impedance, bandpass amplification, and stray capacitance reduction. With a view to applying the AFE to capacitive biopotential measurements (CBMs), the three features were investigated separately in a schematic and mathematical manner. Capacitive electrocardiogram (cECG) or capacitive electromyogram (cEMG) measurements using the AFE were performed in low-humidity conditions (below 35% relative humidity) for a total of seven human subjects. Performance evaluation of the AFE revealed the following: (1) the proposed AFE in cECG measurement with 1.70-mm thick clothing reduced the baseline recovery time and root mean square voltage of respiratory interference in subjects with healthy-weight body mass index (BMI), and increased R-wave amplitude for overweight-BMI subjects; and (2) the proposed AFE in cEMG measurement of biceps brachii muscle yielded stable electromyographic waveforms without the marked DC component for all subjects and a significant (p < 0.01) increase in the signal-to-noise ratio. These results indicate that the proposed AFE can provide a feasible balance between sensitivity and stability in CBMs, and it could be a versatile replacement for the conventional voltage follower used in CBMs.
Collapse
Affiliation(s)
- Hajime Nakamura
- Master’s Program in Electrical and Electronic Engineering, Graduate School of Engineering, Tokyo Denki University, Tokyo 120-8551, Japan; (H.N.); (Y.S.); (H.I.)
| | - Yuichiro Sakajiri
- Master’s Program in Electrical and Electronic Engineering, Graduate School of Engineering, Tokyo Denki University, Tokyo 120-8551, Japan; (H.N.); (Y.S.); (H.I.)
| | - Hiroshi Ishigami
- Master’s Program in Electrical and Electronic Engineering, Graduate School of Engineering, Tokyo Denki University, Tokyo 120-8551, Japan; (H.N.); (Y.S.); (H.I.)
| | - Akinori Ueno
- Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo 120-8551, Japan
- Correspondence: ; Tel.: +81-3-5284-5404
| |
Collapse
|
4
|
Massaroni C, Nicolò A, Lo Presti D, Sacchetti M, Silvestri S, Schena E. Contact-Based Methods for Measuring Respiratory Rate. SENSORS (BASEL, SWITZERLAND) 2019; 19:E908. [PMID: 30795595 PMCID: PMC6413190 DOI: 10.3390/s19040908] [Citation(s) in RCA: 125] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 02/15/2019] [Accepted: 02/17/2019] [Indexed: 01/05/2023]
Abstract
There is an ever-growing demand for measuring respiratory variables during a variety of applications, including monitoring in clinical and occupational settings, and during sporting activities and exercise. Special attention is devoted to the monitoring of respiratory rate because it is a vital sign, which responds to a variety of stressors. There are different methods for measuring respiratory rate, which can be classed as contact-based or contactless. The present paper provides an overview of the currently available contact-based methods for measuring respiratory rate. For these methods, the sensing element (or part of the instrument containing it) is attached to the subject's body. Methods based upon the recording of respiratory airflow, sounds, air temperature, air humidity, air components, chest wall movements, and modulation of the cardiac activity are presented. Working principles, metrological characteristics, and applications in the respiratory monitoring field are presented to explore potential development and applicability for each method.
Collapse
Affiliation(s)
- Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| | - Andrea Nicolò
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", 00135 Rome, Italy.
| | - Daniela Lo Presti
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| | - Massimo Sacchetti
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", 00135 Rome, Italy.
| | - Sergio Silvestri
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| |
Collapse
|
5
|
Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing. SENSORS 2018; 18:s18072144. [PMID: 29970861 PMCID: PMC6068602 DOI: 10.3390/s18072144] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 06/15/2018] [Accepted: 06/27/2018] [Indexed: 01/06/2023]
Abstract
In this paper, a first approach to the design of a portable device for non-contact monitoring of respiratory rate by capacitive sensing is presented. The sensing system is integrated into a smart vest for an untethered, low-cost and comfortable breathing monitoring of Chronic Obstructive Pulmonary Disease (COPD) patients during the rest period between respiratory rehabilitation exercises at home. To provide an extensible solution to the remote monitoring using this sensor and other devices, the design and preliminary development of an e-Health platform based on the Internet of Medical Things (IoMT) paradigm is also presented. In order to validate the proposed solution, two quasi-experimental studies have been developed, comparing the estimations with respect to the golden standard. In a first study with healthy subjects, the mean value of the respiratory rate error, the standard deviation of the error and the correlation coefficient were 0.01 breaths per minute (bpm), 0.97 bpm and 0.995 (p < 0.00001), respectively. In a second study with COPD patients, the values were −0.14 bpm, 0.28 bpm and 0.9988 (p < 0.0000001), respectively. The results for the rest period show the technical and functional feasibility of the prototype and serve as a preliminary validation of the device for respiratory rate monitoring of patients with COPD.
Collapse
|
6
|
Takano M, Ueno A. Noncontact In-Bed Measurements of Physiological and Behavioral Signals Using an Integrated Fabric-Sheet Sensing Scheme. IEEE J Biomed Health Inform 2018; 23:618-630. [PMID: 29994011 DOI: 10.1109/jbhi.2018.2825020] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Home monitoring requires measuring the physiological and behavioral signals without impairing a subject's everyday life. This paper presents an integrated and noncontact approach for obtaining simultaneous physiological and behavioral signals of recumbent humans in beds using a home-monitoring application. In the proposed approach, a fabric-sheet unified sensing electrode (FUSE) obtains physiological signals by recording the electrocardiogram (ECG), chest and abdominal respiratory movements (RMs), and ballistocardiogram (BCG). The FUSE also detects the behavioral signals of body proximity (BPx) and lateral/supine lying postures. A prototype system with FUSE was validated in a short-term experiment and 6-h overnight measurements on two different groups composed of seven lying subjects. The results confirmed that the approach senses each signal independently and records the ECG, RMs, BCG, and BPx signals simultaneously. The mean sensitivities of the R and T waves of the ECG during sleep were 86.1% and 88.0%, respectively, whereas those of the chest and abdominal RMs were 90.7% and 90.1%, respectively. Although our prototype system has room for improvement, the results suggest that our approach enables the unconstrained, nocturnal monitoring of the physiological and behavioral signals in recumbent humans. The at-home monitoring of the physiological and behavioral signals is expected to contribute to cost-effective personalized healthcare in the future. This noncontact and easy-to-install system for in-bed measurements can facilitate a new era of home monitoring.
Collapse
|
7
|
Castro ID, Varon C, Torfs T, Van Huffel S, Puers R, Van Hoof C. Evaluation of a Multichannel Non-Contact ECG System and Signal Quality Algorithms for Sleep Apnea Detection and Monitoring. SENSORS (BASEL, SWITZERLAND) 2018; 18:E577. [PMID: 29438344 PMCID: PMC5855940 DOI: 10.3390/s18020577] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 02/09/2018] [Accepted: 02/11/2018] [Indexed: 12/02/2022]
Abstract
Sleep-related conditions require high-cost and low-comfort diagnosis at the hospital during one night or longer. To overcome this situation, this work aims to evaluate an unobtrusive monitoring technique for sleep apnea. This paper presents, for the first time, the evaluation of contactless capacitively-coupled electrocardiography (ccECG) signals for the extraction of sleep apnea features, together with a comparison of different signal quality indicators. A multichannel ccECG system is used to collect signals from 15 subjects in a sleep environment from different positions. Reference quality labels were assigned for every 30-s segment. Quality indicators were calculated, and their signal classification performance was evaluated. Features for the detection of sleep apnea were extracted from capacitive and reference signals. Sleep apnea features related to heart rate and heart rate variability achieved high similarity to the reference values, with p-values of 0.94 and 0.98, which is in line with the more than 95% beat-matching obtained. Features related to signal morphology presented lower similarity with the reference, although signal similarity metrics of correlation and coherence were relatively high. Quality-based automatic classification of the signals had a maximum accuracy of 91%. Best-performing quality indicators were based on template correlation and beat-detection. Results suggest that using unobtrusive cardiac signals for the automatic detection of sleep apnea can achieve similar performance as contact signals, and indicates clinical value of ccECG. Moreover, signal segments can automatically be classified by the proposed quality metrics as a pre-processing step. Including contactless respiration signals is likely to improve the performance and provide a complete unobtrusive cardiorespiratory monitoring solution; this is a promising alternative that will allow the screening of more patients with higher comfort, for a longer time, and at a reduced cost.
Collapse
Affiliation(s)
- Ivan D Castro
- KU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium.
- IMEC Belgium, 3001 Leuven, Belgium.
| | - Carolina Varon
- KU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium.
- IMEC Belgium, 3001 Leuven, Belgium.
| | | | - Sabine Van Huffel
- KU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium.
- IMEC Belgium, 3001 Leuven, Belgium.
| | - Robert Puers
- KU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium.
- IMEC Belgium, 3001 Leuven, Belgium.
| | - Chris Van Hoof
- KU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium.
- IMEC Belgium, 3001 Leuven, Belgium.
| |
Collapse
|