1
|
Velarde-Ruiz Velasco J, Tapia Calderón D, Llop Herrera E, Castro Narro G, García Jiménez E, Cerda Reyes E, Higuera de la Tijera F, Cano Contreras A, Moreno Alcántar R, Chávez Ramírez R, Calleja Panero J. Más allá de la exploración física convencional en hepatología: POCUS. REVISTA DE GASTROENTEROLOGÍA DE MÉXICO 2023; 88:381-391. [DOI: 10.1016/j.rgmx.2023.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/21/2025]
|
2
|
Velarde-Ruiz Velasco JA, Tapia Calderón DK, Llop Herrera E, Castro Narro G, García Jiménez ES, Cerda Reyes E, Higuera de la Tijera F, Cano Contreras AD, Moreno Alcántar R, Chávez Ramírez RM, Calleja Panero JL. Beyond conventional physical examination in hepatology: POCUS. REVISTA DE GASTROENTEROLOGIA DE MEXICO (ENGLISH) 2023; 88:381-391. [PMID: 37833134 DOI: 10.1016/j.rgmxen.2023.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 07/26/2023] [Indexed: 10/15/2023]
Abstract
Point-of-care ultrasound (POCUS) refers to the use of ultrasound imaging through pocket-sized sonographic devices at the patient's bedside, to make a diagnosis or direct a procedure and immediately answer a clinical question. Its goal is to broaden the physical examination, not to replace conventional ultrasound studies. POCUS has evolved as a complement to physical examination and has been adopted by different medical specialties, including hepatology. A narrative synthesis of the evidence on the applications of POCUS in hepatology was carried out, describing its usefulness in the diagnosis of cirrhosis of the liver, metabolic dysfunction-associated steatotic liver disease (MASLD), decompensated cirrhosis, and portal hypertension. The review also encompasses more recent applications in the hemodynamic evaluation of the critically ill patient with cirrhosis of the liver, patients with other liver diseases, as well as in the ultrasound guidance of procedures. POCUS could make up part of the daily clinical practice of gastroenterologists and hepatologists, simplifying the initial evaluation of patients and optimizing clinical management. Its accessibility, ease of use, and low adverse event profile make POCUS a useful tool for the properly trained physician in the adequate clinical setting. The aim of this review was to describe the available evidence on the usefulness of POCUS in the daily clinical practice of gastroenterologists and hepatologists.
Collapse
Affiliation(s)
- J A Velarde-Ruiz Velasco
- Servicio de Gastroenterología, Hospital Civil de Guadalajara Fray Antonio Alcalde, Guadalajara, Jalisco, Mexico; Departamento de Clínicas Médicas, Centro Universitario de Ciencias de la Salud, Universidad de Guadalajara, Guadalajara, Jalisco, Mexico
| | - D K Tapia Calderón
- Servicio de Gastroenterología y Hepatología, Hospital Universitario Puerta de Hierro, IDIPHISA, Ciberhd, Majadahonda, Madrid, Spain.
| | - E Llop Herrera
- Servicio de Gastroenterología y Hepatología, Hospital Universitario Puerta de Hierro, IDIPHISA, Ciberhd, Majadahonda, Madrid, Spain
| | - G Castro Narro
- Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - E S García Jiménez
- Servicio de Gastroenterología, Hospital Civil de Guadalajara Fray Antonio Alcalde, Guadalajara, Jalisco, Mexico
| | - E Cerda Reyes
- Servicio de Gineco-Obstetricia, Hospital Central Militar, Mexico City, Mexico
| | - F Higuera de la Tijera
- Servicio de Gastroenterología, Hospital General de México Dr. Eduardo Liceaga, Mexico City, Mexico
| | - A D Cano Contreras
- Instituto de Investigaciones Médico-Biológicas, Universidad Veracruzana, Veracruz, Mexico
| | - R Moreno Alcántar
- Unidad Médica de Alta Especialidad Hospital de Especialidades CMN SXXI, Mexico City, Mexico
| | - R M Chávez Ramírez
- Unidad de Cuidados Intensivos, Hospital de Ginecoobstetricia, UMAE CMNO IMSS, Guadalajara, Jalisco, Mexico
| | - J L Calleja Panero
- Servicio de Gastroenterología y Hepatología, Hospital Universitario Puerta de Hierro, IDIPHISA, Ciberhd, Majadahonda, Madrid, Spain
| |
Collapse
|
3
|
Jafarzadeh E, Démoré CE, Burns PN, Goertz DE. Spatially segmented SVD clutter filtering in cardiac blood flow imaging with diverging waves. ULTRASONICS 2023; 132:107006. [PMID: 37116399 DOI: 10.1016/j.ultras.2023.107006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 03/18/2023] [Accepted: 04/03/2023] [Indexed: 05/29/2023]
Abstract
Ultrafast ultrasound imaging enables the visualization of rapidly changing blood flow dynamics in the chambers of the heart. Singular value decomposition (SVD) filters outperform conventional high pass clutter rejection filters for ultrafast blood flow imaging of small and shallow fields of view (e.g., functional imaging of brain activity). However, implementing SVD filters can be challenging in cardiac imaging due to the complex spatially and temporally varying tissue characteristics. To address this challenge, we describe a method that involves excluding the proximal portion of the image (near the chest wall) and divides the reduced field of view into overlapped segments, within which tissue signals are expected to be spatially and temporally coherent. SVD filtering with automatic selection of cut-off singular vector orders to remove tissue and noise signals is implemented for each segment. Auto-thresholding is based on the coherence of spatial singular vectors, delineating tissue, blood, and noise subspaces within a spatial similarity matrix calculated for each segment. Filtered blood flow signals from the segments are reconstructed and then combined and Doppler processing is used to form a set of blood flow images. Preliminary experimental results suggest that the spatially segmented approach improves the separation of the tissue and blood subsets in the spatial similarity matrix so that automatic thresholding is significantly improved, and tissue clutter can then be rejected more effectively in cardiac ultrafast imaging, compared to using the full field of view. In the case studied, spatially segmented SVD improved the rate of correct automatic selection of thresholds from 78% to 98.7% for the investigated cases and improved the post-filter power of blood signals by an average of more than 10 dB during a cardiac cycle.
Collapse
Affiliation(s)
- Ehsan Jafarzadeh
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada; Department of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada.
| | - Christine Em Démoré
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada; Department of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada.
| | - Peter N Burns
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada; Department of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada.
| | - David E Goertz
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada; Department of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada.
| |
Collapse
|
4
|
Haniel J, Yiu BYS, Chee AJY, Huebner R, Yu ACH. Efficacy of ultrasound vector flow imaging in tracking omnidirectional pulsatile flow. Med Phys 2023; 50:1699-1714. [PMID: 36546560 DOI: 10.1002/mp.16168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 11/21/2022] [Accepted: 11/23/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Ultrasound vector flow imaging (VFI) shows potential as an emerging non-invasive modality for time-resolved flow mapping. However, its efficacy in tracking multidirectional pulsatile flow with temporal resolvability has not yet been systematically evaluated because of the lack of an appropriate test protocol. PURPOSE We present the first systematic performance investigation of VFI in tracking pulsatile flow in a meticulously designed scenario with time-varying, omnidirectional flow fields (with flow angles from 0° to 360°). METHODS Ultrasound VFI was performed on a three-loop spiral flow phantom (4 mm diameter; 5 mm pitch) that was configured to operate under pulsatile flow conditions (10 ml/s peak flow rate; 1 Hz pulse rate; carotid pulse shape). The spiral lumen geometry was designed to simulate recirculatory flow dynamics observed in the heart and in curvy blood vessel segments such as the carotid bulb. The imaging sequence was based on steered plane wave pulsing (-10°, 0°, +10° steering angles; 5 MHz imaging frequency; 3.3 kHz interleaved pulse repetition frequency). VFI's pulsatile flow estimation performance and its ability to detect secondary flow were comparatively assessed against flow fields derived from computational fluid dynamics (CFD) simulations that included consideration of fluid-structure interactions (FSI). The mean percentage error (MPE) and the coefficient of determination (R2 ) were computed to assess the correspondence of the velocity estimates derived from VFI and CFD-FSI simulations. In addition, VFI's efficacy in tracking pulse waves was analyzed with respect to pressure transducer measurements made at the phantom's inlet and outlet. RESULTS Pulsatile flow patterns rendered by VFI agreed with the flow profiles computed from CFD-FSI simulations (average MPE: -5.3%). The shape of the VFI-measured velocity magnitude profile generally matched the inlet flow profile. High correlation exists between VFI measurements and simulated flow vectors (lateral velocity: R2 = 0.8; axial velocity R2 = 0.89; beam-flow angle: R2 = 0.98; p < 0.0001 for all three quantities). VFI was found to be capable of consistently tracking secondary flow. It also yielded pulse wave velocity (PWV) estimates (5.72 ± 1.02 m/s) that, on average, are within 6.4% of those obtained from pressure transducer measurements (6.11 ± 1.15 m/s). CONCLUSION VFI can consistently track omnidirectional pulsatile flow on a time-resolved basis. This systematic investigation serves well as a quality assurance test of VFI.
Collapse
Affiliation(s)
- Jonathas Haniel
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
- Department of Mechanical Engineering, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Billy Y S Yiu
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Adrian J Y Chee
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Rudolf Huebner
- Department of Mechanical Engineering, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Alfred C H Yu
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
5
|
Bhatti A, Ishii T, Kanno N, Ikeda H, Funamoto K, Saijo Y. Region-based SVD processing of high-frequency ultrafast ultrasound to visualize cutaneous vascular networks. ULTRASONICS 2023; 129:106907. [PMID: 36495767 DOI: 10.1016/j.ultras.2022.106907] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 10/24/2022] [Accepted: 11/27/2022] [Indexed: 06/17/2023]
Abstract
Observing alterations in cutaneous vasculature in response to any disease or pathology is considered as a potential diagnostic marker in the progression and cure of a disease. To observe skin morphologies and tissue conditions, high-frequency ultrasound (HFUS) has been used in dermatology, although its ability to selectively visualize micro-vessels is limited due to insufficient Doppler sensitivity to peripheral slow-speed blood flow. In recent studies, this issue has been improved by increasing the sensitivity of Doppler imaging to slow flow, leveraging advanced cutter filtering approaches based on singular value decomposition (SVD) techniques that aid to effectively extract flow signals overlapped with tissue echo signals. Nevertheless, in skin imaging, variations in flow speed, diameter, and depth of the blood vessels at different skin layers can make clutter filtering challenging because these variations are problematic in selecting the optimal cut-off value for the SVD filtering. In this study, we aimed to devise a novel region-based SVD filtering approach for ultrafast HFUS data to visualize cutaneous vascular networks. The proposed method divides the acquired high-framerate data into two regions based on B-mode cutaneous morphological identification (dermis layer and subcutaneous tissue). Singular value decomposition processing was performed on each region to effectively extract the desired flow signal, and the processed regions were merged to generate a single power Doppler image, thereby highlighting the appearance of a complete cutaneous vascular network. Finally, top-hat transform was applied to the power Doppler image to further suppress the background noises and enhances the visibility of the micro-vessels. Experimental observations of the human cutaneous circulation showed that the image quality (contrast-to-noise ratio) through the region-based SVD filtering was measured to be 4.1 dB (before top-hat filtering) and 5.2 dB (after top-hat filtering), which were improved from 3.4 dB and 4.0 dB obtained using the global SVD approach with and without top-hat filtering, respectively. We envisioned that this approach would provide diverse applications in the diagnosis of cutaneous disorders.
Collapse
Affiliation(s)
- Anam Bhatti
- Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8579, Miyagi, Japan
| | - Takuro Ishii
- Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8579, Miyagi, Japan; Frontier Research Institute for Interdisciplinary Sciences, Tohoku University, Sendai 980-0845, Miyagi, Japan.
| | - Naoya Kanno
- Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8579, Miyagi, Japan
| | - Hayato Ikeda
- Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8579, Miyagi, Japan
| | - Kenichi Funamoto
- Institute of Fluid Science, Tohoku University, Sendai 980-8577, Miyagi, Japan
| | - Yoshifumi Saijo
- Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8579, Miyagi, Japan
| |
Collapse
|
6
|
Pham DH, Basarab A, Zemmoura I, Remenieras JP, Kouame D. Joint Blind Deconvolution and Robust Principal Component Analysis for Blood Flow Estimation in Medical Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:969-978. [PMID: 32997626 DOI: 10.1109/tuffc.2020.3027956] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
This article addresses the problem of high-resolution Doppler blood flow estimation from an ultrafast sequence of ultrasound images. Formulating the separation of clutter and blood components as an inverse problem has been shown in the literature to be a good alternative to spatio-temporal singular value decomposition (SVD)-based clutter filtering. In particular, a deconvolution step has recently been embedded in such a problem to mitigate the influence of the point spread function (PSF) of the imaging system. Deconvolution was shown in this context to improve the accuracy of the blood flow reconstruction. However, the PSF needs to be measured experimentally, and measuring it requires nontrivial experimental setups. To overcome this limitation, we propose herein a blind deconvolution method able to estimate both the blood component and the PSF from Doppler data. Numerical experiments conducted on simulated and in vivo data demonstrate qualitatively and quantitatively the effectiveness of the proposed approach in comparison with the previous method based on experimentally measured PSF and two other state-of-the-art approaches.
Collapse
|
7
|
Baranger J, Arnal B, Perren F, Baud O, Tanter M, Demene C. Adaptive Spatiotemporal SVD Clutter Filtering for Ultrafast Doppler Imaging Using Similarity of Spatial Singular Vectors. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1574-1586. [PMID: 29969408 DOI: 10.1109/tmi.2018.2789499] [Citation(s) in RCA: 157] [Impact Index Per Article: 22.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Singular value decomposition of ultrafast imaging ultrasonic data sets has recently been shown to build a vector basis far more adapted to the discrimination of tissue and blood flow than the classical Fourier basis, improving by large factor clutter filtering and blood flow estimation. However, the question of optimally estimating the boundary between the tissue subspace and the blood flow subspace remained unanswered. Here, we introduce an efficient estimator for automatic thresholding of subspaces and compare it to an exhaustive list of thirteen estimators that could achieve this task based on the main characteristics of the singular components, namely the singular values, the temporal singular vectors, and the spatial singular vectors. The performance of those fourteen estimators was tested in vitro in a large set of controlled experimental conditions with different tissue motion and flow speeds on a phantom. The estimator based on the degree of resemblance of spatial singular vectors outperformed all others. Apart from solving the thresholding problem, the additional benefit with this estimator was its denoising capabilities, strongly increasing the contrast to noise ratio and lowering the noise floor by at least 5 dB. This confirms that, contrary to conventional clutter filtering techniques that are almost exclusively based on temporal characteristics, efficient clutter filtering of ultrafast Doppler imaging cannot overlook space. Finally, this estimator was applied in vivo on various organs (human brain, kidney, carotid, and thyroid) and showed efficient clutter filtering and noise suppression, improving largely the dynamic range of the obtained ultrafast power Doppler images.
Collapse
|
8
|
Yiu BYS, Yu ACH. Spiral Flow Phantom for Ultrasound Flow Imaging Experimentation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1840-1848. [PMID: 29035216 DOI: 10.1109/tuffc.2017.2762860] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
As new ultrasound flow imaging methods are being developed, there is a growing need to devise appropriate flow phantoms that can holistically assess the accuracy of the derived flow estimates. In this paper, we present a novel spiral flow phantom design whose Archimedean spiral lumen naturally gives rise to multi-directional flow over all possible angles (i.e., from 0° to 360°). Developed using lost-core casting principles, the phantom geometry comprised a three-loop spiral (4-mm diameter and 5-mm pitch), and it was set to operate in steady flow mode (3 mL/s flow rate). After characterizing the flow pattern within the spiral vessel using computational fluid dynamics (CFD) simulations, the phantom was applied to evaluate the performance of color flow imaging (CFI) and high-frame-rate vector flow imaging. Significant spurious coloring artifacts were found when using CFI to visualize flow in the spiral phantom. In contrast, using vector flow imaging (least-squares multi-angle Doppler based on a three-transmit and three-receive configuration), we observed consistent depiction of flow velocity magnitude and direction within the spiral vessel lumen. The spiral flow phantom was also found to be a useful tool in facilitating demonstration of dynamic flow visualization based on vector projectile imaging. Overall, these results demonstrate the spiral flow phantom's practical value in analyzing the efficacy of ultrasound flow estimation methods.
Collapse
|
9
|
Kim SY, Kim KW, Choi SH, Kwon JH, Song GW, Kwon HJ, Yun YJ, Lee J, Lee SG. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2611-2618. [PMID: 28843618 DOI: 10.1016/j.ultrasmedbio.2017.07.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Revised: 06/19/2017] [Accepted: 07/22/2017] [Indexed: 06/07/2023]
Abstract
To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility.
Collapse
Affiliation(s)
- Se-Young Kim
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Kyoung Won Kim
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
| | - Sang Hyun Choi
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jae Hyun Kwon
- Division of Liver Transplantation and Hepatobiliary Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Gi-Won Song
- Division of Liver Transplantation and Hepatobiliary Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Heon-Ju Kwon
- Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Young Ju Yun
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jeongjin Lee
- School of Computer Science and Engineering, Soongsil University, Seoul, Korea
| | - Sung-Gyu Lee
- Division of Liver Transplantation and Hepatobiliary Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
10
|
Choi JW, Jae HJ, Kim HC, Yi NJ, Lee KW, Suh KS, Chung JW. Long-term outcome of endovascular intervention in hepatic venous outflow obstruction following pediatric liver transplantation. Liver Transpl 2015. [PMID: 26197765 DOI: 10.1002/lt.24215] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The purpose of our study was to address the long-term outcome of angioplasty and stent placement for hepatic venous outflow obstruction following pediatric liver transplantation. From October 1999 to December 2011, 20 stenotic lesions were confirmed to constitute hepatic venous outflow obstruction in 18 pediatric patients (13 boys, 5 girls) among 152 pediatric patients following liver transplantation and were managed with endovascular intervention. Stent placement was favored over additional angioplasty in patients of preadolescent or adolescent age (>8 years old), after 1 or 2 sessions of balloon angioplasty. The primary patency and assisted primary patency were estimated using the Kaplan-Meier method. A total of 32 procedures (24 balloon angioplasties, 8 stent placements) were conducted. The technical success rate was 90.6% (29/32). Clinical success was achieved in 15 of 18 patients (clinical success rate of 83.3%). Major complications did not occur in our study. Median follow-up was 91.5 months (interquartile range, 54.7-137.3 months) for the 18 patients. The 1-year, 3-year, 5-year, and 10-year primary patencies of the 20 treated lesions were 63.5%, 57.8%, 57.8%, and 57.8%, respectively. The 1-year, 3-year, 5-year, and 10-year assisted-primary patencies of the lesions were 100%, 100%, 100%, and 100%, respectively. Of the 6 patients of preadolescent or adolescent age, 5 patients underwent stent placement procedures, and the stents were patent during the follow-up period of 57.3-162.5 months (median, 72.7 months). In conclusion, endovascular intervention is very effective in hepatic venous outflow obstruction following pediatric liver transplantation. In addition, early stent placement in patients of preadolescent or adolescent age can provide a safe and favorable long-term outcome.
Collapse
Affiliation(s)
- Jin Woo Choi
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Hwan Jun Jae
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Hyo-Cheol Kim
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Nam-Joon Yi
- Department of Surgery, Seoul National University Hospital, Seoul, Korea
| | - Kwang-Woong Lee
- Department of Surgery, Seoul National University Hospital, Seoul, Korea
| | - Kyung-Suk Suh
- Department of Surgery, Seoul National University Hospital, Seoul, Korea
| | - Jin Wook Chung
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| |
Collapse
|