1
|
Zgouridou A, Kenanidis E, Potoupnis M, Tsiridis E. Global mapping of institutional and hospital-based (Level II-IV) arthroplasty registries: a scoping review. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1219-1251. [PMID: 37768398 PMCID: PMC10858160 DOI: 10.1007/s00590-023-03691-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 08/13/2023] [Indexed: 09/29/2023]
Abstract
PURPOSE Four joint arthroplasty registries (JARs) levels exist based on the recorded data type. Level I JARs are national registries that record primary data. Hospital or institutional JARs (Level II-IV) document further data (patient-reported outcomes, demographic, radiographic). A worldwide list of Level II-IV JARs must be created to effectively assess and categorize these data. METHODS Our study is a systematic scoping review that followed the PRISMA guidelines and included 648 studies. Based on their publications, the study aimed to map the existing Level II-IV JARs worldwide. The secondary aim was to record their lifetime, publications' number and frequency and recognise differences with national JARs. RESULTS One hundred five Level II-IV JARs were identified. Forty-eight hospital-based, 45 institutional, and 12 regional JARs. Fifty JARs were found in America, 39 in Europe, nine in Asia, six in Oceania and one in Africa. They have published 485 cohorts, 91 case-series, 49 case-control, nine cross-sectional studies, eight registry protocols and six randomized trials. Most cohort studies were retrospective. Twenty-three per cent of papers studied patient-reported outcomes, 21.45% surgical complications, 13.73% postoperative clinical and 5.25% radiographic outcomes, and 11.88% were survival analyses. Forty-four JARs have published only one paper. Level I JARs primarily publish implant revision risk annual reports, while Level IV JARs collect comprehensive data to conduct retrospective cohort studies. CONCLUSIONS This is the first study mapping all Level II-IV JARs worldwide. Most JARs are found in Europe and America, reporting on retrospective cohorts, but only a few report on studies systematically.
Collapse
Affiliation(s)
- Aikaterini Zgouridou
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eustathios Kenanidis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece.
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece.
| | - Michael Potoupnis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eleftherios Tsiridis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| |
Collapse
|
2
|
Howell SM, Sappey-Marinier E, Niesen AE, Nedopil AJ, Hull ML. Better forgotten joint scores when the angle of the prosthetic trochlea is lateral to the quadriceps vector in kinematically aligned total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2023; 31:5438-5445. [PMID: 37792084 DOI: 10.1007/s00167-023-07598-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 09/15/2023] [Indexed: 10/05/2023]
Abstract
PURPOSE The primary aim was to analyze unrestricted kinematic alignment (unKA) total knee arthroplasty (TKA) and determine the frequency of medial deviation of the prosthetic trochlear angle (PTA) of the femoral component relative to the quadriceps vector (QV) that terminates at the anterior inferior iliac spine (AIIS), and whether patients with medial deviation had a worse Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) relative to those with lateral deviation. The secondary aim was to determine the frequency of medial deviation for mechanical alignment (MA) TKA simulations. METHODS From a database of a single surgeon, the study extracted de-identified data on 147 patients with a CT scanogram showing the pelvis and AIIS, a limb with an unKA TKA, and a native (i.e., healthy) opposite limb. On the scanogram, an examiner, blinded to the PROMs, measured the PTA-QV angle on the unKA TKA and on the opposite limb simulated MA TKA by drawing the PTA at 6° valgus relative to the femoral mechanical axis and measuring the PTA-QV angle. RESULTS Medial deviation of the PTA occurred in 86% of patients with unKA TKA, and the 126 with medial deviation had a 17/1 point worse median FJS/OKS than the 21 with lateral deviation at a mean follow-up of 47 ± 8 months, respectively (p < 0.0001, p = 0.0053). In addition, 21%, 17%, and 8% of MA TKA had medial deviation after radiographic simulation using reported surgical errors for manual, patient-specific, and robotic instrumentation, respectively. CONCLUSION In most patients with unKA TKA and a smaller proportion with MA TKA, a PTA of 6° valgus was medial to the QV, which, by excluding the patient's Q-angle, might alter patellofemoral kinematics like an incorrectly oriented trochleoplasty. The 17-point worse FJS in the patients with an unKA TKA and medial deviation of the PTA suggests the surgical target should be to orient the PTA lateral to the QV. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Stephen M Howell
- Department of Biomedical Engineering, University of California, Davis, CA, 95616, USA
| | - Elliot Sappey-Marinier
- Department of Orthopaedic Surgery, University of California, San Francisco, CA, 94143, USA.
- Department of Orthopaedic Surgery, Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, 69008, Lyon, France.
| | - Abigail E Niesen
- Department of Biomedical Engineering, University of California, Davis, CA, 95616, USA
| | - Alexander J Nedopil
- Orthopädische Klinik König-Ludwig-Haus, Lehrstuhl für Orthopädie der Universität Würzburg, 97074, Würzburg, Germany
| | - Maury L Hull
- Department of Biomedical Engineering, University of California, Davis, CA, 95616, USA
- Department of Orthopedic Surgery, University of California, Davis Medical Center, Sacramento, CA, 95817, USA
- Department of Mechanical Engineering, University of California, Davis, CA, 95616, USA
| |
Collapse
|
3
|
Twomey-Kozak J, Hurley E, Levin J, Anakwenze O, Klifto C. Technological innovations in shoulder replacement: current concepts and the future of robotics in total shoulder arthroplasty. J Shoulder Elbow Surg 2023; 32:2161-2171. [PMID: 37263482 DOI: 10.1016/j.jse.2023.04.022] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/04/2023] [Accepted: 04/12/2023] [Indexed: 06/03/2023]
Abstract
BACKGROUND Total shoulder arthroplasty (TSA) has been rapidly evolving over the last several decades, with innovative technological strategies being investigated and developed in order to achieve optimal component precision and joint alignment and stability, preserve implant longevity, and improve patient outcomes. Future advancements such as robotic-assisted surgeries, augmented reality, artificial intelligence, patient-specific instrumentation (PSI) and other peri- and preoperative planning tools will continue to revolutionize TSA. Robotic-assisted arthroplasty is a novel and increasingly popular alternative to the conventional arthroplasty procedure in the hip and knee but has not yet been investigated in the shoulder. Therefore, the purpose of this study was to conduct a narrative review of the literature on the evolution and projected trends of technological advances and robotic assistance in total shoulder arthroplasty. METHODS A narrative synthesis method was employed for this review, rather than a meta-analysis or systematic review of the literature. This decision was based on 2 primary factors: (1) the lack of eligible, peer-reviewed studies with high-quality level of evidence available for review on robotic-assisted shoulder arthroplasty, and (2) a narrative review allows for a broader scope of content analysis, including a comprehensive review of all technological advances-including robotics-within the field of TSA. A general literature search was performed using PubMed, Embase, and Cochrane Library databases. These databases were queried by 2 independent reviewers from database inception through November 11, 2022, for all articles investigating the role of robotics and technology assistance in total shoulder arthroplasty. Inclusion criteria included studies describing "shoulder arthroplasty" and "robotics." RESULTS After exclusion criteria were applied, 4 studies on robotic-assisted TSA were described in the review. Given the novelty of this technology and limited data on robotics in TSA, these studies consisted of a literature review, nonvalidated experimental biomechanical studies in sawbones models, and preclinical proof-of-concept cadaveric studies using prototype robotic technology primarily in conjunction with PSI. The remaining studies described the technological advancements in TSA, including PSI, computer-assisted navigation, artificial intelligence, machine learning, and virtual, augmented, and mixed reality. Although not yet commercially available, robotic-assisted TSA confers the theoretical advantages of precise humeral head cuts for restoration of proximal humerus anatomy, more accurate glenoid preparation, and improved soft-tissue assessment in limited early studies. CONCLUSION The evidence for the use of robotics in total hip arthroplasty and total knee arthroplasty demonstrates improved component accuracy, more precise radiographic measurements, and improved early/mid-term patient-reported and functional outcomes. Although no such data currently exist for shoulder arthroplasty given that the technology has not yet been commercialized, the lessons learned from robotic hip and knee surgery in conjunction with its rapid adoption suggests robotic-assisted TSA is on the horizon of innovation. By achieving a better understanding of the past, present, and future innovations in TSA through this narrative review, orthopedic surgeons can be better prepared for future applications.
Collapse
Affiliation(s)
- Jack Twomey-Kozak
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA.
| | - Eoghan Hurley
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Jay Levin
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Oke Anakwenze
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Christopher Klifto
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
4
|
Tibesku CO, Haas SB, Saunders C, Harwood DA. Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis. Arch Orthop Trauma Surg 2023; 143:4379-4393. [PMID: 36449066 PMCID: PMC10293358 DOI: 10.1007/s00402-022-04698-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 11/10/2022] [Indexed: 12/05/2022]
Abstract
INTRODUCTION Malalignment and resulting complications are major challenges in total knee arthroplasty (TKA) which patient-specific instrumentation (PSI) is proposed to alleviate. Previous PSI meta-analyses of TKA outcomes typically do not differentiate between PSI systems and assess relatively few outcomes, so the value of their findings is limited. VISIONAIRE™ cutting guides (Smith + Nephew Inc., Memphis, TN, USA) is a PSI system based on preoperative magnetic resonance and X-ray imaging. A systematic literature review (SLR) and meta-analysis, focussed specifically on VISIONAIRE, were conducted to assess TKA accuracy, intraoperative outcomes, and postoperative outcomes, compared with conventional instrumentation (CI). MATERIALS AND METHODS The SLR was performed using PubMed, Embase, and Google Scholar databases to identify relevant studies published until March 2022. Depending on statistical heterogeneity, meta-analyses were performed for outcome measures with fixed effect (I2 < 50%) or random-effects models (I2 ≥ 50%). Dichotomous outcomes were reported as odds ratios and continuous outcomes were reported as mean differences. Descriptive analyses were performed for outcomes not amenable to meta-analysis. RESULTS Outcomes for VISIONAIRE versus CI were reported in 25 studies. Compared with CI, VISIONAIRE reduced odds of mechanical outliers by 40% (p < 0.0001), with no statistically significant differences in odds of overall coronal, sagittal, or rotational plane component outliers. VISIONAIRE improved surgical efficiency (operating room, turnover, and tourniquet times reduced by 7.3% (p = 0.02), 42% (p = 0.022), and 15.9% (p = 0.01), respectively), lowering the odds of blood transfusion by 53% (p = 0.01) and shortening patients' hospital stays (11.1% reduction; p < 0.0001). There were no significant differences between groups in incidence of postoperative complications and (descriptively analyzed) return-to-function outcomes. CONCLUSION Options for PSI in TKA differ substantially, and it is important to assess the outcomes of individual systems. The current findings suggest that VISIONAIRE guides can lead to improved alignment accuracy and surgical efficiency compared with CI, without compromising postoperative safety and return-to-function outcomes.
Collapse
Affiliation(s)
| | - Steven B Haas
- Knee Surgery, Hospital for Special Surgery, Weill Cornell Medical College, New York, NY, USA
| | | | | |
Collapse
|
5
|
Schönthaler W, Dauwe J, Holzer LA. Patient-specific instrumentation in total knee arthroplasty: a review of the current literature. Acta Orthop Belg 2023; 89:299-306. [PMID: 37924556 DOI: 10.52628/89.2.11543] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2023]
Abstract
Total knee arthroplasty (TKA) is one of the most frequently performed interventions in the field of Orthopaedic surgery. Over the last decades the implantation technique has improved continuously. The majority of patients is satisfied with the clinical outcome of TKA. However in various clinical follow-ups, up to 20% of unsatisfied patients can be observed. Periprosthetic infection and aseptic loosening seem to be the most common reasons for failure. Malalignment has been discussed as a cause of aseptic loosening and often leads to revision surgery. In order to increase the precision of implant positioning and alignment, new technologies such as patient-specific instrumentation (PSI) have been developed. Since the introduction of PSI, multiple clinical studies have been performed analyzing the clinical and radiological outcome of TKA with PSI technique. This review covers the recent literature of PSI in respect to surgical accuracy, clinical outcome, time- and cost-effectiveness.
Collapse
|
6
|
Hinloopen JH, Puijk R, Nolte PA, Schoones JW, de Ridder R, Pijls BG. The efficacy and safety of patient-specific instrumentation in primary total knee replacement: a systematic review and meta-analysis. Expert Rev Med Devices 2023; 20:245-252. [PMID: 36736371 DOI: 10.1080/17434440.2023.2177152] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
INTRODUCTION Patient-specific instrumentation (PSI) for primary total knee arthroplasty (TKA) surgery has been shown to increase accuracy of component positioning. However, it is unclear whether this also translates to actual benefits for patients in terms of better outcomes (efficacy) or less complications such as revisions (safety). We therefore systematically reviewed the literature to determine the efficacy and safety of PSI in primary TKA. METHODS Randomized controlled trials comparing PSI to non-PSI in primary TKA were included. A random effects model was used with meta-regression in case of heterogeneity. RESULTS Forty-three studies were included with a total of 1816 TKA in the PSI group and 1887 TKA in the control group. There were no clinically relevant differences between the PSI-group and non-PSI group regarding all outcomes. There was considerable heterogeneity: meta-regression analyses showed that the year the study was published was an important effect modifier. Early publications tended to show a positive effect for PSI compared to non-PSI TKA, whereas later studies found the opposite. CONCLUSION Based on evidence of moderate certainty, our study suggested that there were no clinically relevant differences in efficacy and safety between patients treated with PSI TKA and patients treated with non-PSI TKA.
Collapse
Affiliation(s)
- J H Hinloopen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - R Puijk
- Department of Orthopedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - P A Nolte
- Department of Orthopedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands.,Department Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - J W Schoones
- Directorate of Research Policy (Formerly: Walaeus Library), Leiden University Medical Centre, Leiden, The Netherlands
| | - R de Ridder
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands.,Department of Orthopaedics, Reinier Haga Orthopaedic Centre, Zoetermeer, Netherlands
| | - B G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
7
|
Pereira EG, Carvalho MM, Oliveira T, Sacramento T, Cruz H, Viegas R, Fontes AP, Marreiros A, Sousa JP. Benefits of Tranexamic Acid in Total Knee Arthroplasty: A Classification and Regression Tree Analysis in Function of Instrumentation, BMI, and Gender. J Knee Surg 2023; 36:173-180. [PMID: 34225366 DOI: 10.1055/s-0041-1731455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Tranexamic acid (TXA) is an antifibrinolytic drug that reduces blood loss in patients that undergo Total knee arthroplasty (TKA). Few studies compare its effect on conventional instrumentation (CI) versus patient-specific instrumentation (PSI). The main objective of this study was to understand analytically how TXA usage in both instrumentations influenced blood loss in TKA differently and see if the differences seen could be explained by the patient's body mass index (BMI) and gender. This nonrandomized retrospective study sample consisted of 688 TKA procedures performed on patients who had symptomatic arthrosis resistant to conservative treatment. Descriptive analysis was used to evaluate blood loss using hemoglobin (Hb) mean values and mean variation (%). The Classification and Regression Tree (CRT) method was applied to understand how the independent variables affected the dependent variable. Comparing patients submitted to the same instrumentation, where some received TXA and others did not, patients that received TXA had lower blood loss. Comparing patients who underwent TKA with different instrumentations and without the use of TXA, it was found that patients who underwent TKA with PSI had lower blood loss than those who underwent TKA with CI. However, when these same instruments were compared again, but associated with the use of TXA, the opposite was true with patients undergoing TKA with PSI showing greater blood loss than patients undergoing TKA with CI. TXA usage in TKA is significantly beneficial in minimizing blood loss and regardless of instrumentation. When using TXA, the lowest blood loss was obtained in patients with higher BMI and submitted to TKA with CI. This is most likely explained by the synergistic antifibrotic effect of TXA with adipokines, such as plasminogen activator inhibitor-1 (PAI-1), found in the femoral bone marrow which is perforated using CI. If, however, TXA wasn't used, the lowest blood loss was obtained in patients submitted to TKA with PSI.
Collapse
Affiliation(s)
- Eduardo G Pereira
- Universidade do Algarve-Faculdade de Medicina e Ciências Biomédicas, Campus de Gambelas Faro, Portugal
| | - Maria M Carvalho
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Tiago Oliveira
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Telmo Sacramento
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Henrique Cruz
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Rui Viegas
- Departamento de Ortopedia e Traumatologia, Hospital Beatriz Ângelo, Loures, Portugal
| | - Ana P Fontes
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| | - Ana Marreiros
- Universidade do Algarve-Faculdade de Medicina e Ciências Biomédicas, Campus de Gambelas Faro, Portugal.,Algarve Biomedical Center - Research Institute (ABC-RI)-Faculdade de Medicina e Ciência Biomédicas, Campus de Gambelas Faro, Portugal
| | - João P Sousa
- Departamento de Ortopedia e Traumatologia, Hospital Particular do Algarve-Urbanização Casal de Gambelas, Lote 2, Gambelas Faro, Portugal
| |
Collapse
|
8
|
Accuracy of a Three-Dimensional (3D)-Printed Patient-Specific (PS) Femoral Osteotomy Guide: A Computed Tomography (CT) Study. Bioengineering (Basel) 2022; 9:bioengineering9110667. [PMID: 36354578 PMCID: PMC9687720 DOI: 10.3390/bioengineering9110667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 11/02/2022] [Accepted: 11/03/2022] [Indexed: 11/11/2022] Open
Abstract
Femoral neck osteotomy creates a critical anatomical landmark for surgeons performing primary Total Hip Arthroplasty (THA); it affects the final height and position of the femoral component. Patient Specific Instrumentation (PSI) has been developed to guide the osteotomy. We aimed to assess the accuracy of a patient-specific (PS) femoral osteotomy guide in primary THA using three-dimensional (3D) computed tomography (CT) analysis. We included pre- and post-operative CT data of 103 THAs. All patients underwent 3D planning to define the optimal femoral neck osteotomy level. Our primary objective was to quantify the discrepancy between the achieved and planned osteotomy level; our secondary objective was to evaluate the clinical outcome. The median (Interquartile Range—IQR) discrepancy between the achieved and planned osteotomy level was 0.3 mm (−1 mm to 2 mm). We found a strong positive correlation between the planned and achieved osteotomy level (R2 = 0.9, p < 0.001). A satisfactory clinical outcome was recorded. Our findings suggest that surgeons can use 3D-printed PS guides to achieve a femoral neck osteotomy with a high level of accuracy to the plan.
Collapse
|
9
|
León-Muñoz VJ, López-López M, Santonja-Medina F. Patient-specific instrumentation makes sense in total knee arthroplasty. Expert Rev Med Devices 2022; 19:489-497. [PMID: 35903900 DOI: 10.1080/17434440.2022.2108320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) surgery was initially developed to increase accuracy. The potential PSI benefits have expanded in the last decade, and other advantages have been published. However, different authors are critical of PSI and argue that the advantages are not such and do not compensate for the extra cost. This article aims to describe the recently published advantages and disadvantages of PSI. AREAS COVERED Narrative description of the latest publications related to PSI in accuracy, clinical and functional outcomes, operative time, efficiency, and other benefits. EXPERT COMMENTARY We have published high accuracy of the system, with a not clinically relevant loss of accuracy, significantly higher precision with PSI than with conventional instruments, and a high percentage of cases in the optimal range and similar to that obtained with computer-assisted navigation, greater imprecision for tibial slope, a significant blood loss reduction, and time consumption, an acceptable and non-significant increase in the cost per procedure and no difference in complications during hospital admission and at 90 days. We think that PSI will not follow the Scott Parabola and that it will continue to be a valuable type of device in some instances of TKA surgery.
Collapse
Affiliation(s)
- Vicente J León-Muñoz
- Department of Orthopedic Surgery and Traumatology. Hospital General Universitario Reina Sofía. Murcia (Spain)
| | - Mirian López-López
- Subdirección General de Tecnologías de la Información. Servicio Murciano de Salud. Murcia (Spain)
| | - Fernando Santonja-Medina
- Department of Orthopedic Surgery and Traumatology. Hospital Clínico Universitario Virgen de la Arrixaca. Murcia (Spain).,Department of Surgery, Pediatrics and Obstetrics & Gynecology, Faculty of Medicine, University of Murcia. Murcia (Spain)
| |
Collapse
|
10
|
Innovations in Shoulder Arthroplasty. J Clin Med 2022; 11:jcm11102799. [PMID: 35628933 PMCID: PMC9144112 DOI: 10.3390/jcm11102799] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 05/07/2022] [Accepted: 05/12/2022] [Indexed: 11/22/2022] Open
Abstract
Innovations currently available with anatomic total shoulder arthroplasty include shorter stem designs and augmented/inset/inlay glenoid components. Regarding reverse shoulder arthroplasty (RSA), metal augmentation, including custom augments, on both the glenoid and humeral side have expanded indications in cases of bone loss. In the setting of revision arthroplasty, humeral options include convertible stems and newer tools to improve humeral implant removal. New strategies for treatment and surgical techniques have been developed for recalcitrant shoulder instability, acromial fractures, and infections after RSA. Finally, computer planning, navigation, PSI, and augmented reality are imaging options now available that have redefined preoperative planning and indications as well intraoperative component placement. This review covers many of the innovations in the realm of shoulder arthroplasty.
Collapse
|
11
|
León-Muñoz VJ, López-López M, Lisón-Almagro AJ, Martínez-Martínez F, Santonja-Medina F. Computed Tomography-Based Patient-Specific Instrumentation Loses Accuracy with Significant Varus Preoperative Misalignment. J Knee Surg 2022; 35:574-582. [PMID: 32898903 DOI: 10.1055/s-0040-1716381] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Patient-specific instrumentation (PSI) has been introduced to simplify and make total knee arthroplasty (TKA) surgery more precise, effective, and efficient. We performed this study to determine whether the postoperative coronal alignment is related to preoperative deformity when computed tomography (CT)-based PSI is used for TKA surgery, and how the PSI approach compares with deformity correction obtained with conventional instrumentation. We analyzed pre- and post-operative full length standing hip-knee-ankle (HKA) X-rays of the lower limb in both groups using a convention > 180 degrees for valgus alignment and < 180 degrees for varus alignment. For the PSI group, the mean (± SD) pre-operative HKA angle was 172.09 degrees varus (± 6.69 degrees) with a maximum varus alignment of 21.5 degrees (HKA 158.5) and a maximum valgus alignment of 14.0 degrees. The mean post-operative HKA was 179.43 degrees varus (± 2.32 degrees) with a maximum varus alignment of seven degrees and a maximum valgus alignment of six degrees. There has been a weak correlation among the values of the pre- and post-operative HKA angle. The adjusted odds ratio (aOR) of postoperative alignment outside the range of 180 ± 3 degrees was significantly higher with a preoperative varus misalignment of 15 degrees or more (aOR: 4.18; 95% confidence interval: 1.35-12.96; p = 0.013). In the control group (conventional instrumentation), this loss of accuracy occurs with preoperative misalignment of 10 degrees. Preoperative misalignment below 15 degrees appears to present minimal influence on postoperative alignment when a CT-based PSI system is used. The CT-based PSI tends to lose accuracy with preoperative varus misalignment over 15 degrees.
Collapse
Affiliation(s)
- Vicente Jesús León-Muñoz
- Department of Orthopaedic Surgery, Hospital Clinico Universitario Virgen de la Arrixaca, El Palmar, Spain
| | - Mirian López-López
- Subdirección General de Tecnologías de la Información, Servicio Murciano de Salud, Murcia, Spain
| | | | - Francisco Martínez-Martínez
- Department of Orthopaedic Surgery, Hospital Clinico Universitario Virgen de la Arrixaca, El Palmar, Spain.,Department of Surgery, Pediatrics and Obstetrics & Gynecology, Faculty of Medicine, University of Murcia, Murcia, Spain
| | - Fernando Santonja-Medina
- Department of Orthopaedic Surgery, Hospital Clinico Universitario Virgen de la Arrixaca, El Palmar, Spain.,Department of Surgery, Pediatrics and Obstetrics & Gynecology, Faculty of Medicine, University of Murcia, Murcia, Spain
| |
Collapse
|
12
|
Arnholdt J, Kamawal Y, Horas K, Holzapfel BM, Gilbert F, Ripp A, Rudert M, Steinert AF. Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty. BMC Musculoskelet Disord 2020; 21:699. [PMID: 33092567 PMCID: PMC7583183 DOI: 10.1186/s12891-020-03707-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 10/09/2020] [Indexed: 01/18/2023] Open
Abstract
Background For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal™ CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA). Methods We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal™ CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses. Results On average, HKA was corrected from 174.4° ± 4.6° preoperatively to 178.8° ± 2.2° postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4°. The measured preoperative tibial slope was 5.3° ± 2.2° (mean +/− SD) and the average postoperative tibial slope was 4.7° ± 1.1° on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 ± 0.16 pre- and 1.67 ± 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm ± 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm ± 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching. Conclusion The patient-specific iTotal™ CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system.
Collapse
Affiliation(s)
- Jörg Arnholdt
- Department of Orthopaedic Surgery, König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstraße 11, D-97074, Würzburg, Germany.
| | - Yama Kamawal
- Department of Orthopaedic Surgery, König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstraße 11, D-97074, Würzburg, Germany
| | - Konstantin Horas
- Department of Orthopaedic Surgery, König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstraße 11, D-97074, Würzburg, Germany
| | - Boris M Holzapfel
- Department of Orthopaedic Surgery, König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstraße 11, D-97074, Würzburg, Germany.,Regenerative Medicine, Institute of Health and Biomedical Innovation, Queensland University of Technology, 60 Musk Ave, Kelvin Grove, Brisbane, 4059, Australia
| | - Fabian Gilbert
- Department of Orthopaedic Surgery, König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstraße 11, D-97074, Würzburg, Germany.,Department of Trauma, Hand, Plastic and Reconstructive Surgery, Julius-Maximilians-University Würzburg, D-97080, Würzburg, Germany
| | - Axel Ripp
- Department of Trauma and Orthopaedic Surgery, Elblandklinikum Radebeul, Heinrich-Zille-Straße 13, D-01445, Radebeul, Germany
| | - Maximilian Rudert
- Department of Orthopaedic Surgery, König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstraße 11, D-97074, Würzburg, Germany
| | - Andre F Steinert
- Department of Orthopaedic Surgery, König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstraße 11, D-97074, Würzburg, Germany.,Rhön-Klinikum Campus Bad Neustadt, Department of Orthopaedic, Trauma, Shoulder and Arthroplasty Surgery, Von-Guttenberg-Straße 11, D-97616, Bad Neustadt a. d. Saale, Germany
| |
Collapse
|
13
|
Trivedi NN, Shimberg JL, Sivasundaram L, Mengers S, Salata MJ, Voos JE, Gillespie RJ. Advances in Glenoid Design in Anatomic Total Shoulder Arthroplasty. J Bone Joint Surg Am 2020; 102:1825-1835. [PMID: 33086353 DOI: 10.2106/jbjs.19.01294] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Nikunj N Trivedi
- Department of Orthopaedics, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | | | | | | | | | | | | |
Collapse
|