• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4594882)   Today's Articles (4729)   Subscriber (49328)
For: Matena J, Gieseke M, Kampmann A, Petersen S, Murua Escobar H, Sternberg K, Haferkamp H, Gellrich NC, Nolte I. Characterisation of Cell Growth on Titanium Scaffolds Made by Selective Laser Melting for Tissue Engineering. ACTA ACUST UNITED AC 2013;58 Suppl 1:/j/bmte.2013.58.issue-s1-C/bmt-2013-4047/bmt-2013-4047.xml. [PMID: 24042642 DOI: 10.1515/bmt-2013-4047] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Number Cited by Other Article(s)
1
Cosma C, Kessler J, Gebhardt A, Campbell I, Balc N. Improving the Mechanical Strength of Dental Applications and Lattice Structures SLM Processed. MATERIALS (BASEL, SWITZERLAND) 2020;13:E905. [PMID: 32085482 PMCID: PMC7078848 DOI: 10.3390/ma13040905] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 02/10/2020] [Accepted: 02/15/2020] [Indexed: 01/07/2023]
2
Rana M, Chin SJ, Muecke T, Kesting M, Groebe A, Riecke B, Heiland M, Gellrich NC. Increasing the accuracy of mandibular reconstruction with free fibula flaps using functionalized selective laser-melted patient-specific implants: A retrospective multicenter analysis. J Craniomaxillofac Surg 2017;45:1212-1219. [DOI: 10.1016/j.jcms.2017.04.003] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Revised: 01/25/2017] [Accepted: 04/10/2017] [Indexed: 11/30/2022]  Open
3
Tan N, Liu X, Cai Y, Zhang S, Jian B, Zhou Y, Xu X, Ren S, Wei H, Song Y. The influence of direct laser metal sintering implants on the early stages of osseointegration in diabetic mini-pigs. Int J Nanomedicine 2017;12:5433-5442. [PMID: 28814861 PMCID: PMC5546787 DOI: 10.2147/ijn.s138615] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]  Open
4
Poly-ε-caprolactone Coated and Functionalized Porous Titanium and Magnesium Implants for Enhancing Angiogenesis in Critically Sized Bone Defects. Int J Mol Sci 2015;17:ijms17010001. [PMID: 26703586 PMCID: PMC4730248 DOI: 10.3390/ijms17010001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 12/10/2015] [Accepted: 12/14/2015] [Indexed: 11/26/2022]  Open
5
Rotaru H, Schumacher R, Kim SG, Dinu C. Selective laser melted titanium implants: a new technique for the reconstruction of extensive zygomatic complex defects. Maxillofac Plast Reconstr Surg 2015;37:1. [PMID: 25654072 PMCID: PMC4309900 DOI: 10.1186/s40902-015-0001-9] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2015] [Accepted: 01/09/2015] [Indexed: 11/13/2022]  Open
6
Direct metal laser sintering titanium dental implants: a review of the current literature. Int J Biomater 2014;2014:461534. [PMID: 25525434 PMCID: PMC4267165 DOI: 10.1155/2014/461534] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Revised: 10/16/2014] [Accepted: 11/06/2014] [Indexed: 12/14/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA