1
|
Neugebauer F, Möddel G, Rampp S, Burger M, Wolters CH. The Effect of Head Model Simplification on Beamformer Source Localization. Front Neurosci 2017; 11:625. [PMID: 29209157 PMCID: PMC5701642 DOI: 10.3389/fnins.2017.00625] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Accepted: 10/26/2017] [Indexed: 11/13/2022] Open
Abstract
Beamformers are a widely-used tool in brain analysis with magnetoencephalography (MEG) and electroencephalography (EEG). For the construction of the beamformer filters realistic head volume conductor modeling is necessary for accurately computing the EEG and MEG leadfields, i.e., for solving the EEG and MEG forward problem. In this work, we investigate the influence of including realistic head tissue compartments into a finite element method (FEM) model on the beamformer's localization ability. Specifically, we investigate the effect of including cerebrospinal fluid, gray matter, and white matter distinction, as well as segmenting the skull bone into compacta and spongiosa, and modeling white matter anisotropy. We simulate an interictal epileptic measurement with white sensor noise. Beamformer filters are constructed with unit gain, unit array gain, and unit noise gain constraint. Beamformer source positions are determined by evaluating power and excess sample kurtosis (g2) of the source-waveforms at all source space nodes. For both modalities, we see a strong effect of modeling the cerebrospinal fluid and white and gray matter. Depending on the source position, both effects can each be in the magnitude of centimeters, rendering their modeling necessary for successful localization. Precise skull modeling mainly effected the EEG up to a few millimeters, while both modalities could profit from modeling white matter anisotropy to a smaller extent of 5-10 mm. The unit noise gain or neural activity index beamformer behaves similarly to the array gain beamformer when noise strength is sufficiently high. Variance localization seems more robust against modeling errors than kurtosis.
Collapse
Affiliation(s)
- Frank Neugebauer
- Institute for Biomagnetism und Biosignalanalysis, University of Münster, Münster, Germany
| | - Gabriel Möddel
- Department of Sleep Medicine and Neuromuscular Disorders, Epilepsy Center Münster-Osnabrück, University of Münster, Münster, Germany
| | - Stefan Rampp
- Department of Neurosurgery, University Hospital Erlangen, Erlangen, Germany
| | - Martin Burger
- Institute for Computational and Applied Mathematics, University of Münster, Münster, Germany
| | - Carsten H. Wolters
- Institute for Biomagnetism und Biosignalanalysis, University of Münster, Münster, Germany
| |
Collapse
|
2
|
Azizollahi H, Aarabi A, Wallois F. Effects of uncertainty in head tissue conductivity and complexity on EEG forward modeling in neonates. Hum Brain Mapp 2016; 37:3604-22. [PMID: 27238749 DOI: 10.1002/hbm.23263] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 05/04/2016] [Accepted: 05/09/2016] [Indexed: 11/09/2022] Open
Abstract
In this study, we investigated the impact of uncertainty in head tissue conductivities and inherent geometrical complexities including fontanels in neonates. Based on MR and CT coregistered images, we created a realistic neonatal head model consisting of scalp, skull, fontanels, cerebrospinal fluid (CSF), gray matter (GM), and white matter (WM). Using computer simulations, we investigated the effects of exclusion of CSF and fontanels, discrimination between GM and WM, and uncertainty in conductivity of neonatal head tissues on EEG forward modeling. We found that exclusion of CSF from the head model induced the strongest widespread effect on the EEG forward solution. Discrimination between GM and white matter also induced a strong widespread effect, but which was less intense than that of CSF exclusion. The results also showed that exclusion of the fontanels from the neonatal head model locally affected areas beneath the fontanels, but this effect was much less pronounced than those of exclusion of CSF and GM/WM discrimination. Changes in GM/WM conductivities by 25% with respect to reference values induced considerable effects in EEG forward solution, but this effect was more pronounced for GM conductivity. Similarly, changes in skull conductivity induced effects in the EEG forward modeling in areas covered by the cranial bones. The least intense effect on EEG was caused by changes in conductivity of the fontanels. Our findings clearly emphasize the impact of uncertainty in conductivity and deficiencies in head tissue compartments on modeling research and localization of brain electrical activity in neonates. Hum Brain Mapp 37:3604-3622, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Hamed Azizollahi
- GRAMFC, Inserm U1105, University Research Center, Department of Medicine, Amiens University Hospital, Amiens, France
| | - Ardalan Aarabi
- GRAMFC, Inserm U1105, University Research Center, Department of Medicine, Amiens University Hospital, Amiens, France
| | - Fabrice Wallois
- GRAMFC, Inserm U1105, University Research Center, Department of Medicine, Amiens University Hospital, Amiens, France.,EFSN Pediatric (Pediatric Nervous System Functional Investigation Unit), Department of Pediatrics, CHU AMIENS-SITE SUD, Amiens, France
| |
Collapse
|
3
|
Interpreting EEG alpha activity. Neurosci Biobehav Rev 2014; 44:94-110. [DOI: 10.1016/j.neubiorev.2013.05.007] [Citation(s) in RCA: 259] [Impact Index Per Article: 25.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2012] [Revised: 04/05/2013] [Accepted: 05/03/2013] [Indexed: 01/04/2023]
|
4
|
Vorwerk J, Cho JH, Rampp S, Hamer H, Knösche TR, Wolters CH. A guideline for head volume conductor modeling in EEG and MEG. Neuroimage 2014; 100:590-607. [PMID: 24971512 DOI: 10.1016/j.neuroimage.2014.06.040] [Citation(s) in RCA: 188] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Revised: 05/30/2014] [Accepted: 06/18/2014] [Indexed: 11/30/2022] Open
Abstract
For accurate EEG/MEG source analysis it is necessary to model the head volume conductor as realistic as possible. This includes the distinction of the different conductive compartments in the human head. In this study, we investigated the influence of modeling/not modeling the conductive compartments skull spongiosa, skull compacta, cerebrospinal fluid (CSF), gray matter, and white matter and of the inclusion of white matter anisotropy on the EEG/MEG forward solution. Therefore, we created a highly realistic 6-compartment head model with white matter anisotropy and used a state-of-the-art finite element approach. Starting from a 3-compartment scenario (skin, skull, and brain), we subsequently refined our head model by distinguishing one further of the above-mentioned compartments. For each of the generated five head models, we measured the effect on the signal topography and signal magnitude both in relation to a highly resolved reference model and to the model generated in the previous refinement step. We evaluated the results of these simulations using a variety of visualization methods, allowing us to gain a general overview of effect strength, of the most important source parameters triggering these effects, and of the most affected brain regions. Thereby, starting from the 3-compartment approach, we identified the most important additional refinement steps in head volume conductor modeling. We were able to show that the inclusion of the highly conductive CSF compartment, whose conductivity value is well known, has the strongest influence on both signal topography and magnitude in both modalities. We found the effect of gray/white matter distinction to be nearly as big as that of the CSF inclusion, and for both of these steps we identified a clear pattern in the spatial distribution of effects. In comparison to these two steps, the introduction of white matter anisotropy led to a clearly weaker, but still strong, effect. Finally, the distinction between skull spongiosa and compacta caused the weakest effects in both modalities when using an optimized conductivity value for the homogenized compartment. We conclude that it is highly recommendable to include the CSF and distinguish between gray and white matter in head volume conductor modeling. Especially for the MEG, the modeling of skull spongiosa and compacta might be neglected due to the weak effects; the simplification of not modeling white matter anisotropy is admissible considering the complexity and current limitations of the underlying modeling approach.
Collapse
Affiliation(s)
- Johannes Vorwerk
- Institut für Biomagnetismus und Biosignalanalyse, Westfälische Wilhelms-Universität, Münster, Germany.
| | - Jae-Hyun Cho
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Stefan Rampp
- Epilepsiezentrum, Universitätsklinikum Erlangen, Erlangen, Germany
| | - Hajo Hamer
- Epilepsiezentrum, Universitätsklinikum Erlangen, Erlangen, Germany
| | - Thomas R Knösche
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Carsten H Wolters
- Institut für Biomagnetismus und Biosignalanalyse, Westfälische Wilhelms-Universität, Münster, Germany
| |
Collapse
|
5
|
Kybartaite A. Computational representation of a realistic head and brain volume conductor model: electroencephalography simulation and visualization study. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2012; 28:1144-1155. [PMID: 23109383 DOI: 10.1002/cnm.2483] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2011] [Revised: 02/08/2012] [Accepted: 03/26/2012] [Indexed: 06/01/2023]
Abstract
Computational head and brain volume conductor modeling is a practical and non-invasive method to investigate neuroelectrical activity in the brain. Anatomical structures included in a model affect the flow of volume currents and the resulting scalp surface potentials. The influence of different tissues within the head on scalp surface potentials was investigated by constructing five highly detailed, realistic head models from segmented and processed Visible Human Man digital images. The models were: (1) model with 20 different tissues, that is, skin, dense connective tissue (fat), aponeurosis (muscle), outer, middle and inner tables of the scalp, dura matter, arachnoid layer (including cerebrospinal fluid), pia matter, six cortical layers, eye tissue, muscle around the eye, optic nerve, temporal muscle, white matter and internal air, (2) model with three main inhomogeneities, that is, scalp, skull, brain, (3) model with homogeneous scalp and remaining inhomogeneities, (4) model with homogeneous skull and remaining inhomogeneities, and (5) model with homogeneous brain matter and remaining inhomogeneities. Scalp potentials because of three different dipolar sources in the parietal-occipital lobe were computed for all five models. Results of a forward solution revealed that tissues included in the model and the dipole source location directly affect the simulated scalp surface potentials. The major finding indicates that significant change in the scalp surface potentials is observed when the brain's distinctions are removed. The other modifications, for example, layers of the scalp and skull are important too, but they have less effect on the overall results.
Collapse
Affiliation(s)
- Asta Kybartaite
- Institute of Neurosciences, Lithuanian University of Health Sciences, Kaunas, Lithuania.
| |
Collapse
|
6
|
Effects of local tissue conductivity on spherical and realistic head models. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2010; 33:233-42. [DOI: 10.1007/s13246-010-0027-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2009] [Accepted: 04/12/2010] [Indexed: 10/19/2022]
|
7
|
Walckiers G, Fuchs B, Thiran JP, Mosig JR, Pollo C. Influence of the implanted pulse generator as reference electrode in finite element model of monopolar deep brain stimulation. J Neurosci Methods 2010; 186:90-6. [DOI: 10.1016/j.jneumeth.2009.10.012] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2009] [Revised: 10/13/2009] [Accepted: 10/13/2009] [Indexed: 11/29/2022]
|
8
|
Jaros U, Hilgenfeld B, Lau S, Curio G, Haueisen J. Nonlinear interactions of high-frequency oscillations in the human somatosensory system. Clin Neurophysiol 2008; 119:2647-57. [PMID: 18829382 DOI: 10.1016/j.clinph.2008.08.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2008] [Revised: 07/28/2008] [Accepted: 08/20/2008] [Indexed: 11/19/2022]
Abstract
OBJECTIVE The source of somatosensory evoked high-frequency activity at about 600 Hz is still not completely clear. Hence, we aimed to study the influence of double stimulation on the human somatosensory system by analyzing both the low-frequency activity and the high-frequency oscillations (HFOs) at about 600 Hz. METHODS We used median nerve stimulation at seven interstimuli intervals (ISIs) with a high time resolution between 2.4 and 4.8 ms to investigate the N15, N20 and superimposed HFOs. Simultaneously, the electroencephalogram and the magnetoencephalogram of 12 healthy participants were recorded. Subsequently, the source analysis of precortical and cortical dipoles was performed. RESULTS The difference computations of precortical dipole activation curves showed in both the low- and high-frequency range a correlation between the ISI and the latency of the second stimulus response. The cortical low-frequency response showed a similar behavior. Contrarily, in the second response of cortical HFOs this latency shift could not be confirmed. We found amplitude fluctuations that were dependent on the ISI in the low-frequency activity and the HFOs. These nonlinear interactions occurred at ISIs, which differ by one full HFO period (1.6 ms). CONCLUSIONS Low-frequency activity and HFOs originate from different generators. Precortical and cortical HFOs are independently generated. The amplitude fluctuations dependent on ISI indicate nonlinear interference between successive stimuli. SIGNIFICANCE Information processing in human somatosensory system includes nonlinearity.
Collapse
Affiliation(s)
- U Jaros
- Biomagnetic Center, Department of Neurology, University Hospital Jena, Erlanger Allee 101, 07747 Jena, Germany
| | | | | | | | | |
Collapse
|
9
|
Wolters CH, Anwander A, Tricoche X, Weinstein D, Koch MA, MacLeod RS. Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: A simulation and visualization study using high-resolution finite element modeling. Neuroimage 2006; 30:813-26. [PMID: 16364662 DOI: 10.1016/j.neuroimage.2005.10.014] [Citation(s) in RCA: 251] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2005] [Revised: 09/15/2005] [Accepted: 10/05/2005] [Indexed: 11/22/2022] Open
Abstract
To achieve a deeper understanding of the brain, scientists, and clinicians use electroencephalography (EEG) and magnetoencephalography (MEG) inverse methods to reconstruct sources in the cortical sheet of the human brain. The influence of structural and electrical anisotropy in both the skull and the white matter on the EEG and MEG source reconstruction is not well understood. In this paper, we report on a study of the sensitivity to tissue anisotropy of the EEG/MEG forward problem for deep and superficial neocortical sources with differing orientation components in an anatomically accurate model of the human head. The goal of the study was to gain insight into the effect of anisotropy of skull and white matter conductivity through the visualization of field distributions, isopotential surfaces, and return current flow and through statistical error measures. One implicit premise of the study is that factors that affect the accuracy of the forward solution will have at least as strong an influence over solutions to the associated inverse problem. Major findings of the study include (1) anisotropic white matter conductivity causes return currents to flow in directions parallel to the white matter fiber tracts; (2) skull anisotropy has a smearing effect on the forward potential computation; and (3) the deeper a source lies and the more it is surrounded by anisotropic tissue, the larger the influence of this anisotropy on the resulting electric and magnetic fields. Therefore, for the EEG, the presence of tissue anisotropy both for the skull and white matter compartment substantially compromises the forward potential computation and as a consequence, the inverse source reconstruction. In contrast, for the MEG, only the anisotropy of the white matter compartment has a significant effect. Finally, return currents with high amplitudes were found in the highly conducting cerebrospinal fluid compartment, underscoring the need for accurate modeling of this space.
Collapse
Affiliation(s)
- C H Wolters
- Westfälische Wilhelms-Universität Münster, Institut für Biomagnetismus und Biosignalanalyse, Malmedyweg 15, 48149 Münster, Germany.
| | | | | | | | | | | |
Collapse
|
10
|
Nolte G. The magnetic lead field theorem in the quasi-static approximation and its use for magnetoencephalography forward calculation in realistic volume conductors. Phys Med Biol 2004; 48:3637-52. [PMID: 14680264 DOI: 10.1088/0031-9155/48/22/002] [Citation(s) in RCA: 630] [Impact Index Per Article: 31.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The equation for the magnetic lead field for a given magnetoencephalography (MEG) channel is well known for arbitrary frequencies omega but is not directly applicable to MEG in the quasi-static approximation. In this paper we derive an equation for omega = 0 starting from the very definition of the lead field instead of using Helmholtz's reciprocity theorems. The results are (a) the transpose of the conductivity times the lead field is divergence-free, and (b) the lead field differs from the one in any other volume conductor by a gradient of a scalar function. Consequently, for a piecewise homogeneous and isotropic volume conductor, the lead field is always tangential at the outermost surface. Based on this theoretical result, we formulated a simple and fast method for the MEG forward calculation for one shell of arbitrary shape: we correct the corresponding lead field for a spherical volume conductor by a superposition of basis functions, gradients of harmonic functions constructed here from spherical harmonics, with coefficients fitted to the boundary conditions. The algorithm was tested for a prolate spheroid of realistic shape for which the analytical solution is known. For high order in the expansion, we found the solutions to be essentially exact and for reasonable accuracies much fewer multiplications are needed than in typical implementations of the boundary element methods. The generalization to more shells is straightforward.
Collapse
Affiliation(s)
- Guido Nolte
- Human Motor Control Section, NINDS, NIH, Bethesda, MD, USA.
| |
Collapse
|
11
|
Tarkiainen A, Liljeström M, Seppä M, Salmelin R. The 3D topography of MEG source localization accuracy: effects of conductor model and noise. Clin Neurophysiol 2003; 114:1977-92. [PMID: 14499760 DOI: 10.1016/s1388-2457(03)00195-0] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE To evaluate the effect that different head conductor models have on the source estimation accuracy of magnetoencephalography (MEG) under realistic conditions. METHODS Magnetic fields evoked by current dipoles were simulated using a highly refined 3-layer realistically shaped conductor model. Noise from a real MEG measurement was added to the simulated fields. Source parameters (location, strength, orientation) were estimated from the noisy signals using 3 spherically symmetric models and several one- and 3-layer realistically shaped boundary-element models. The effect of different measurement sensors (gradiometers, magnetometers) was also tested. RESULTS The noise typically present in brain signals masked the errors due to the different conductor models so that in most situations the models gave comparable results. Active cortical areas around the vertex and in the temporal, frontoparietal, and occipital regions were typically found with 2-4 mm accuracy, whereas source localization in several anterior frontal lobe and deep brain structures yielded errors exceeding 2 cm. Localization in anterior frontal regions may benefit most from the use of realistically shaped models. CONCLUSIONS The traditionally used sphere model is an adequate model for most research purposes. Any means that increase the signal-to-noise ratio are of highest importance in attempting to improve the source estimation accuracy.
Collapse
Affiliation(s)
- A Tarkiainen
- Brain Research Unit, Low Temperature Laboratory, Helsinki University of Technology, P.O. Box 2200, 02015 HUT, Espoo, Finland.
| | | | | | | |
Collapse
|
12
|
Abstract
The current dipole is a widely used source model in forward and inverse electroencephalography and magnetoencephalography applications. Analytic solutions to the governing field equations have been developed for several approximations of the human head using ideal dipoles as the source model. Numeric approaches such as the finite-element and finite-difference methods have become popular because they allow the use of anatomically realistic head models and the increased computational power that they require has become readily available. Although numeric methods can represent more realistic domains, the sources in such models are an approximation of the ideal dipole. In this paper, we examine several methods for representing dipole sources in finite-element models and compare the resulting surface potentials and external magnetic field with those obtained from analytic solutions using ideal dipoles.
Collapse
Affiliation(s)
- Paul H Schimpf
- School of Electrical Engineering and Computer Science, Washington State University, Spokane 99202 USA.
| | | | | |
Collapse
|
13
|
Haueisen J, Tuch DS, Ramon C, Schimpf PH, Wedeen VJ, George JS, Belliveau JW. The influence of brain tissue anisotropy on human EEG and MEG. Neuroimage 2002; 15:159-66. [PMID: 11771984 DOI: 10.1006/nimg.2001.0962] [Citation(s) in RCA: 176] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The influence of gray and white matter tissue anisotropy on the human electroencephalogram (EEG) and magnetoencephalogram (MEG) was examined with a high resolution finite element model of the head of an adult male subject. The conductivity tensor data for gray and white matter were estimated from magnetic resonance diffusion tensor imaging. Simulations were carried out with single dipoles or small extended sources in the cortical gray matter. The inclusion of anisotropic volume conduction in the brain was found to have a minor influence on the topology of EEG and MEG (and hence source localization). We found a major influence on the amplitude of EEG and MEG (and hence source strength estimation) due to the change in conductivity and the inclusion of anisotropy. We expect that inclusion of tissue anisotropy information will improve source estimation procedures.
Collapse
Affiliation(s)
- J Haueisen
- Biomagnetisches Zentrum, Friedrich-Schiller-Universität, Jena, Germany
| | | | | | | | | | | | | |
Collapse
|