Shekarriz P, Hosseini F, Shojaee P. Ultrasound assessment of the nose vasculature: A review of the common method of non-surgical filler-based rhinoplasty. J Cosmet Dermatol 2024; 23:731-736. [PMID: 37846655 DOI: 10.1111/jocd.16037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 10/03/2023] [Indexed: 10/18/2023]
Abstract
BACKGROUND With the increasing use of dermal injectable fillers in aesthetic medicine, the popularity of non-surgical filler-based rhinoplasty (NSR) is also growing. While performing this procedure might result in certain vascular complications, injecting deep into the midline of the nose is commonly considered the safest method for blind primary NSR. AIMS In this study, we challenged the common NSR method with a Doppler ultrasound study of the nose. PATIENTS/METHODS The vascular pattern of the common zones of the NSR procedure (radix and nasal tip) of 21 Iranian women were investigated by using a 14 MHz Doppler handheld ultrasound device (Silarious L14PS). Participants had never undergone any procedure on their nose. We focused on the depth of midline vessels in the radix and nasal tip. The radix was studied sagittally and horizontally, and the nasal tip was examined axially by ultrasound. RESULTS In the radix of eight cases (38%), at least one vessel was observed at midline, and all were superficial. In the nose tip of 18 cases (86%), at least one vessel was observed at midline, and 9 out of these 18 vessels (50%) were deep. As a result, conducting NSR by the common method in our study population was relatively safe in the radix, but there was an increased likelihood of vascular events in the tip. CONCLUSION Our research results show that while the common method of the NSR may carry a high risk of vascular events, the safety of this procedure could be enhanced by using ultrasound for planning and conducting a tailored treatment.
Collapse
|
2
|
Corroenne R, Chesnais M, Khawand C, Attali I, Boucherie AS, Defrance M, Morgan R, Maurey L, Ville Y, Salomon LJ. Physicians' perceptions of the daily use of a handheld ultrasound device in the labor room. J Gynecol Obstet Hum Reprod 2023; 52:102618. [PMID: 37290728 DOI: 10.1016/j.jogoh.2023.102618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/23/2023] [Accepted: 06/05/2023] [Indexed: 06/10/2023]
Abstract
OBJECTIVE The objective of our study was to describe the perception of physicians who use a handheld ultrasound (US) device in an intensive perinatal care unit. METHODS We conducted a prospective observational study in the labor ward of an intensive perinatal care unit between November 2021 and May 2022. Obstetrics & Gynecology residents in rotation in our department during this time were recruited as participants in this study. All the participants were provided with a handheld US device Vscan Air™ (GE Healthcare, Zipf, Austria) to use during their normal days and nights practice in labor ward. At the end of their 6 months rotation, participants completed an anonymous surveys about their perceptions of the handheld US device. The survey included questions about the ease of use in clinical situations, the amount of time of initial diagnosis, performances of the device, feasibility to use, and patient's satisfaction with the use of the device. RESULTS 6 residents in their last year of residency were included. All the participants were satisfied with the device and would like to use it in their future practice. They all agreed that the probe was easy to handle and that the mobile application was easy to use. Image quality was always considered good by the participants and 5/6 of them declared that the handheld US device was always sufficient and did not require any confirmation with a conventional US machine. 5/6 of the participants considered that the handheld US device allowed them to gain time for clinical decision but half of them did not estimate that the use of the handheld US device improved their ability to make a clinical diagnosis. CONCLUSION Our study suggests that the Vscan Air™ is easy to use, with a good quality image and reduces the amount of time to make a clinical diagnosis. Handheld US device could be useful in the daily practice in maternity hospital.
Collapse
Affiliation(s)
- Romain Corroenne
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France; EA fetus 7328 and LUMIERE Platform, University of Paris, Paris, France
| | - Marion Chesnais
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Chelsea Khawand
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Isabelle Attali
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Anne Sophie Boucherie
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Manon Defrance
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Rosemary Morgan
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Louise Maurey
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Yves Ville
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France; EA fetus 7328 and LUMIERE Platform, University of Paris, Paris, France
| | - Laurent J Salomon
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France; EA fetus 7328 and LUMIERE Platform, University of Paris, Paris, France.
| |
Collapse
|
3
|
Alfuraih AM, Alqarni MA, Alhuthaili HS, Mubaraki MY, Alotaibi NN, Almusalim FM. Reproducibility and feasibility of a handheld ultrasound device compared to a standard ultrasound machine in muscle thickness measurements. Australas J Ultrasound Med 2023; 26:13-20. [PMID: 36960135 PMCID: PMC10030094 DOI: 10.1002/ajum.12333] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Objective To test the feasibility and reproducibility of a handheld ultrasound device (HUD) compared to a standard ultrasound machine for muscle thickness measurements in healthy participants. Methods A prospective cross-sectional study was designed where two novice operators tested the thickness of the vastus lateralis, rectus femoris, and vastus intermedius muscles on recruited asymptomatic participants with no history of muscle diseases. The anterior-posterior thickness of each muscle was measured three times per operator to evaluate intra-operator reproducibility and using two machines to evaluate inter-system reproducibility. Scanning started using the HUD followed by the standard system. Intraclass correlation coefficients (ICC) and simple linear regression were used to test for reproducibility and proportional bias respectively. Results A total of 33 male participants volunteered to take part in this study with a mean age of 22.7 years (6.8). Intra-operator reproducibility was almost perfect for both operators on both machines (ICC > 0.80). The measurements difference percentage between the machines ranged from 1.8% to 6.6% and inter-system reproducibility ICC ranged from 0.815 to 0.927 showing excellent reproducibility. Inter-operator reproducibility was poor to moderate on both machines (ICC: 0.522-0.849). Regression analysis showed no proportional bias in the measurements. All measurements were completed successfully using the HUD. Conclusion The HUD demonstrated excellent accuracy compared to the standard ultrasound machine for measuring thigh muscle thickness.
Collapse
Affiliation(s)
- Abdulrahman M. Alfuraih
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Mohammed A. Alqarni
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Hamad S. Alhuthaili
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Meshal Y. Mubaraki
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Nader N. Alotaibi
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Fahad M. Almusalim
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| |
Collapse
|
4
|
Burton L, Bhargava V, Kong M. Point-of-Care Ultrasound in the Pediatric Intensive Care Unit. Front Pediatr 2022; 9:830160. [PMID: 35178366 PMCID: PMC8845897 DOI: 10.3389/fped.2021.830160] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 12/29/2021] [Indexed: 12/30/2022] Open
Abstract
Ultrasonography has been widely used in medicine for decades but often by specific users such as cardiologists, obstetricians, and radiologists. In the last several years, the use of this imaging modality has moved to the bedside, with clinicians performing and interpreting focused point of care ultrasonography to aid in immediate assessment and management of their patients. The growth of point of care ultrasonography has been facilitated by advancement in ultrasound-related technology and emerging studies and protocols demonstrating its utility in clinical practice. However, considerable challenges remain before this modality can be adopted across the spectrum of disciplines, primarily as it relates to training, competency, and standardization of usage. This review outlines the history, current state, challenges and the future direction of point of care ultrasonography specifically in the field of pediatric critical care medicine.
Collapse
|
5
|
Alfuraih AM, Alrashed AI, Almazyad SO, Alsaadi MJ. Abdominal aorta measurements by a handheld ultrasound device compared with a conventional cart-based ultrasound machine. Ann Saudi Med 2021; 41:376-382. [PMID: 34878929 PMCID: PMC8654105 DOI: 10.5144/0256-4947.2021.376] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Ultraportable or pocket handheld ultrasound devices (HUD) may be useful for large-scale abdominal aortic aneurysm screening. However, the reproducibility of measurements has not been compared with conventional cart-based ultrasound machines. OBJECTIVES Investigate the intra- and inter-operator reproducibility of a HUD compared with a conventional ultrasound machine for aortic screening. DESIGN Analytical, cross-sectional. SETTING Ultrasound department at a large tertiary care hospital in Riyadh. PATIENTS AND METHODS Eligible male participants aged ≥60 years were invited to participate upon arriving for a non-vascular ultrasound appointment. Three repeated anteroposterior measurements of the transverse aorta were made at the proximal and distal locations for each machine before repeating the measurements on a subset of participants by a second blinded operator. Intraclass correlation coefficients (ICC) and the Bland-Altman method were used to analyze reproducibility. MAIN OUTCOME MEASURE Inter-system and intra- and inter-operator ICCs. SAMPLE SIZE 114 males with repeated measurements by second operator on a subset of 35 participants. RESULTS The median age (interquartile range) of participants was 68 years (62-74 years). The intra- and inter-operator ICCs were all >0.800 showing almost perfect agreement except for the inter-operator reproducibility at the proximal location using a conventional machine (ICC= 0.583, P=.007) and the Butterfly device (ICC=0.467, P=.037). The inter-system ICCs (95% CI) were 0.818 (0.736-0.874) and 0.879 (0.799-0.924) at the proximal and distal locations, respectively. The mean difference in aortic measurement between the ultrasound systems was 0.3 mm (1.7%) in the proximal location and 0.6 mm (3.6%) in the distal location. In total, >91% of the difference in measurements between the machines was <3 mm. The mean scanning time was 4:16 minutes for the conventional system and 3:53 minutes for the HUD (P=.34). CONCLUSIONS Abdominal aortic screening using a HUD was feasible and reliable compared with a conventional ultrasound machine. A pocket HUD should be considered for large-scale screening. LIMITATIONS No cases of abdominal aortic aneurysm in the sample and lack of blinding. CONFLICT OF INTEREST None.
Collapse
Affiliation(s)
- Abdulrahman M Alfuraih
- From the Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Alkharj, Saudi Arabia
| | - Abdulaziz I Alrashed
- From the Department of Rediodiagnostics and Medical Imaging, Prince Sultan Military Medical City, Riyadh, Saudi Arabia
| | - Saleh O Almazyad
- From the Department of Rediodiagnostics and Medical Imaging, Prince Sultan Military Medical City, Riyadh, Saudi Arabia
| | - Mohammed J Alsaadi
- From the Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Alkharj, Saudi Arabia
| |
Collapse
|
6
|
Affiliation(s)
- José L Díaz-Gómez
- From the Baylor College of Medicine, Houston (J.L.D.-G.); and the Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead (P.H.M.), and the Albert Einstein College of Medicine, New York (S.J.K.) - both in New York
| | - Paul H Mayo
- From the Baylor College of Medicine, Houston (J.L.D.-G.); and the Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead (P.H.M.), and the Albert Einstein College of Medicine, New York (S.J.K.) - both in New York
| | - Seth J Koenig
- From the Baylor College of Medicine, Houston (J.L.D.-G.); and the Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead (P.H.M.), and the Albert Einstein College of Medicine, New York (S.J.K.) - both in New York
| |
Collapse
|
7
|
Malik AN, Rowland J, Haber BD, Thom S, Jackson B, Volk B, Ehrman RR. The Use of Handheld Ultrasound Devices in Emergency Medicine. CURRENT EMERGENCY AND HOSPITAL MEDICINE REPORTS 2021; 9:73-81. [PMID: 33996272 PMCID: PMC8112245 DOI: 10.1007/s40138-021-00229-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/21/2021] [Indexed: 12/23/2022]
Abstract
Purpose of Review Ultraportable handheld ultrasound (HHU) devices are being rapidly adopted by emergency medicine (EM) physicians. Though knowledge of the breadth of their utility and functionality is still limited compared to cart-based systems, these machines are becoming more common due to ease-of-use, extreme affordability, and improving technology. Recent Findings Images obtained with HHU are comparable to those obtained with traditional machines but create unique issues regarding billing and data management. HHU devices are increasingly used successfully to augment the education of practitioners-in-training, by emergency physicians in austere environments, and in the burgeoning fields of "tele-ultrasound" and augmented reality scanning. Summary This review seeks to describe the current state of use of HHU devices in the emergency department (ED) including device overview, institutional concerns, unique areas of use, recent literature since their adoption into clinical EM, and their future potential.
Collapse
Affiliation(s)
- Adrienne N Malik
- Department of Emergency Medicine, University of Kansas School of Medicine, 1450 Jayhawk Blvd, Lawrence, KS 66045 USA
| | - Jonathan Rowland
- Department of Emergency Medicine, University of California-Irvine, 1450 Jayhawk Blvd, Lawrence, KS 66045 USA
| | - Brian D Haber
- Department of Emergency Medicine, Wayne State University School of Medicine, 4201 St. Antoine, Suite 6G, Detroit, MI USA
| | - Stephanie Thom
- Department of Emergency Medicine, University of Kansas School of Medicine, 1450 Jayhawk Blvd, Lawrence, KS 66045 USA
| | - Bradley Jackson
- Department of Emergency Medicine, University of Kansas School of Medicine, 1450 Jayhawk Blvd, Lawrence, KS 66045 USA
| | - Bryce Volk
- Department of Emergency Medicine, University of Kansas School of Medicine, 1450 Jayhawk Blvd, Lawrence, KS 66045 USA
| | - Robert R Ehrman
- Department of Emergency Medicine, Wayne State University School of Medicine, 4201 St. Antoine, Suite 6G, Detroit, MI USA
| |
Collapse
|
8
|
|
9
|
Rykkje A, Carlsen JF, Nielsen MB. Hand-Held Ultrasound Devices Compared with High-End Ultrasound Systems: A Systematic Review. Diagnostics (Basel) 2019; 9:diagnostics9020061. [PMID: 31208078 PMCID: PMC6628329 DOI: 10.3390/diagnostics9020061] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 06/10/2019] [Accepted: 06/13/2019] [Indexed: 12/14/2022] Open
Abstract
The aim of this study was to review the scientific literature available on the comparison of hand-held ultrasound devices with high-end systems for abdominal and pleural applications. PubMed, Embase, Web of Science and Cochrane were searched following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Original research describing hand-held ultrasound devices compared with high-end systems was included and assessed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2. The search was limited to articles published since 1 January 2012. A total of 2486 articles were found and screened by title and abstract. A total of 16 articles were chosen for final review. All of the included articles showed good overall agreement between hand-held and high-end ultrasound systems. Strong correlations were found when evaluating ascites, hydronephrosis, pleural cavities, in detection of abdominal aortic aneurysms and for use with obstetric and gynaecological patients. Other articles found good agreement for cholelithiasis and for determining the best site for paracentesis. QUADAS-2 analysis suggested few risks of bias and almost no concerns regarding applicability. For distinct clinical questions, hand-held devices may be a valuable supplement to physical examination. However, evidence is inadequate, and more research is needed on the abdominal and pleural use of hand-held ultrasound with more standardised comparisons, using only blinded reviewers.
Collapse
Affiliation(s)
- Alexander Rykkje
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
| | | | - Michael Bachmann Nielsen
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
| |
Collapse
|
10
|
Vieillard-Baron A, Millington SJ, Sanfilippo F, Chew M, Diaz-Gomez J, McLean A, Pinsky MR, Pulido J, Mayo P, Fletcher N. A decade of progress in critical care echocardiography: a narrative review. Intensive Care Med 2019; 45:770-788. [DOI: 10.1007/s00134-019-05604-2] [Citation(s) in RCA: 89] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 03/14/2019] [Indexed: 12/12/2022]
|